首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
We exposed Macaca nemestrina (pig-tailed macaques) to electric (E) and magnetic (B) fields ranging in intensity from 3 kV/m and 0.1 G to 30 kV/m and 0.9 G for three 21-day (d) periods. Experimental animals were exposed to sham E and B fields for two 21-d periods, one prior to and one following actual exposure to E and B fields, resulting in a total of five 21-d periods. Control animals were exposed to sham E and B fields for the entire 105-d interval. At the end of each 21-d period cerebrospinal fluid (CSF) was obtained by lumbar puncture and analyzed for concentrations of homovanillic acid (HVA) and 5-hydroxyindoleacetic acid (5-HIAA), metabolites of dopamine and serotonin neurotransmitters, respectively, by high-performance liquid chromatography with electrochemical detection (HPLC-ECD). Results are based on an examination of six experimental and four control animals. Exposure to E and B fields at all strengths was associated with a significant decline in CSF concentrations of both HVA and 5-HIAA when statistical comparisons were made against values obtained at the end of the preexposure interval. However, HVA returned to preexposure levels during the postexposure period, while 5-HIAA did not. No significant change in the concentrations of HVA or 5-HIAA was noted in the control animals. These results strongly suggest that exposure of the nonhuman primate to E and B fields can significantly affect specific biochemical estimates of nervous system function. These effects may involve alterations either in neuronal activity or in the activity of enzymes that catabolize the neurotransmitters.  相似文献   

3.
For in vitro studies on the effect of extremely low frequency (ELF) magnetic field exposures in different laboratories, a programmable, high precision exposure system enabling blinded exposures has been developed and fully characterized. It is based on two shielded 4 coil systems that fit inside a commercial incubator. The volume of uniform B field exposure with 1% field tolerance is 50% larger compared to a Merrit 4 coil system with the same coil volume. The uncertainties for the applied magnetic fields have been specified to be less than 4%. The computer controlled apparatus allows signal waveforms that are composed of several harmonics, blind protocols, monitoring of exposure and environmental conditions and the application of B fields up to 3.6 mT root-mean-square amplitude. Sources of artifacts have been characterized: sham isolation >43 dB, parasitic incident E fields <1 V/m, no recognizable temperature differences in the media for exposure or sham state, and vibrations of the mechanically decoupled dish holder <0.1 m/s(2) (= 0.01 g), which is only twice the sham acceleration background level produced by the incubator and fan vibrations.  相似文献   

4.
A measure of taste-aversion (TA) learning was used in three experiments to 1) determine whether exposure to intense 60-Hz electric fields can produce TA learning in male Sprague-Dawley rats, and 2) establish a dose-response function for the behavior in question. In Experiment 1, four groups of eight rats each were distributed into one of two exposures (69 ± 5 kV/m or 133 ± 10 kV/m) or into one of two sham-exposure groups. Conditioning trials paired 0.1% sodium saccharin in water with 3 h of exposure to a 60-Hz electric field. Following five conditioning trials, a 20-min, two-bottle preference test between water and saccharin-flavored water failed to reveal TA conditioning in exposed groups. In Experiment 2, four groups of eight rats each (34 ± 2 kV/m or 133 ± 10 kV/m and two sham-exposed groups) were treated as before. Electric-field exposure had no effect on TA learning. Experiment 3 tested for a possible synergy between a minimal dose (for TA learning) of cyclophosphamide (6 mg/kg) and 5 h of exposure to 133 ± 10 kV/m electric fields in a dark environment under conditions otherwise similar to those of Experiments 1 and 2. The results indicated no TA learning as reflected in the relative consumption of saccharin.  相似文献   

5.
The purpose of this study was to reproduce and extend an earlier investigation of the effects of human exposure to combined, 60-Hz electric and magnetic fields. This paper presents the neurobehavioral results. Thirty men participated in one training session and four testing sessions. Subjects were randomly assigned to two groups. The 18 subjects in Group I were exposed (9 kV/m, 20 microT) and sham exposed in two counterbalanced orders. In Group II, half of 12 subjects were exposed (9 kV/m, 20 microT) every session, and the remaining half were sham exposed every session. The study was doubly blinded. Measures of cardiac interbeat interval, event-related brain potentials, and performance were obtained before, during, and after exposures. As in the earlier study, exposure to the combined field resulted in a statistically significant slowing of heart rate, in changes in late components of event-related brain potentials, and in decreased errors on a choice reaction-time task. In addition, field effects on several other measures approached statistical significance. The physiological measures obtained during exposure indicated that effects were greatest soon after the field was switched on, and again when it was switched off. The data indicate that changes in exposure level may be more important than duration of exposure for producing effects in human beings.  相似文献   

6.
Honeybee colonies exposed under a 765-kV, 60-Hz transmission line at 7 kV/m show the following sequence of effects: 1) increased motor activity with transient increase in hive temperature; 2) abnormal propolization; 3) impaired hive weight gain; 4) queen loss and abnormal production of queen cells; 5) decreased sealed brood; and 6) poor winter survival. When colonies were exposed at 5 different E fields (7, 5.5, 4.1, 1.8, and 0.65–0.85 kV/m) at incremental distances from the line, different thresholds for biologic effects were obtained. Hive net weights showed significant dose-related lags at the following exposures: 7 kV/m, one week; 5.5 kV/m, 2 weeks; and 4.1 kV/m, 11 weeks. The two lowest exposure groups had normal weight after 25 weeks. Abnormal propolization of hive entrances did not occur below 4.1 kV/m. Queen loss occurred in 6 of 7 colonies at 7 kV/m and 1 of 7 at 5.5 kV/m, but not below. Foraging rates were significantly lower only at 7 and 5.5 kV/m. Hive weight impairment and abnormal propolization occur at lower E-field intensity than other effects and limit the “biological effects corridor” of the transmission line to approximately 23 m beyond a ground line projection of each outer phase wire. Intrahive E fields of 15–100 kV/m were measured with a displacement current sensor. Step-potential-induced currents up to 0.5 μA were measured in an electrically equivalent bee model placed on the honeycomb in a hive exposed at 7 kV/m. At 1.8 kV/m body currents were a few nanoamperes, or two orders of magnitude lower, and these colonies showed no effects. E-field versus electric shock mechanisms are discussed.  相似文献   

7.
This study was undertaken to determine the effects of extremely low frequency (ELF; 60 Hz) electromagnetic (EM) fields on somatic growth and cortical development, as well as biochemical and morphological maturation, of the rat neopallium. On the fifth day of pregnancy, female rats were put in pairs into plastic cages that were housed in a specially constructed apparatus for irradiation under three separate sets of combination and intensity: 1) 1 kV/m and 10 gauss; 2) 100 kV/m and 1 gauss; and 3) 100 kV/m and 10 gauss. The dams were exposed for 23 h daily, from days 5 through 19 postconception after which they were returned to cages outside the exposure apparatus until they littered. The neonates were culled to eight pups per litter. At 0 (birth), 5, 12, and 19 days postnatally, they were killed for biochemical and morphological studies. Another group of pregnant rats was sham-exposed in an identical apparatus, which was not energized, and the pups were used as controls. The irradiated rats exhibited no physical abnormalities, nor did they show brain deformities such as swelling or herniation following exposure to ELF-EM fields. There was no difference in somatic growth between control and exposed rats, but a small reduction in cortical weight was observed in rats exposed at 1 kV/m and 10 gauss, and 100 kV/m and 1 gauss, respectively. Biochemical measurements of DNA. RNA, protein, and cerebroside concentrations indicated that among the three separate exposures, only the neopallium of rats exposed at 1 kV/m and 10 gauss showed a small reduction in DNA level, as well as small reductions in RNA and protein levels. No changes were noticed in cerebroside levels in any exposed animals, and there were no differences in protein/DNA and cerebroside/DNA ratios between control and exposed rats. Morphological observations did not reveal any detectable alterations in the irradiated rats. These results indicate that exposure to ELF-EM fields caused minimal or no changes in somatic growth and cerebral development of the rat. © 1993 Wiley-Liss, Inc.  相似文献   

8.
The aim of the study was to investigate the effects of extremely low-frequency electric field (ELF EF) on visual evoked potential (VEP), thiobarbituric acid reactive substances (TBARS), total antioxidant status (TAS), total oxidant status (TOS), and oxidant stress index (OSI). Thirty female Wistar rats, aged 3 months, were divided into three equal groups: Control (C), the group exposed to EF at 12 kV/m strength (E12), and the group exposed to EF at 18 kV/m strength (E18). Electric field was applied to the E12 and E18 groups for 14 days (1 h/day). Brain and retina TBARS, TOS, and OSI were significantly increased in the E12 and E18 groups with respect to the control group. Also, TBARS levels were significantly increased in the E18 group compared with the E12 group. Electric fields significantly decreased TAS levels in both brain and retina in E12 and E18 groups with respect to the control group. All VEP components were significantly prolonged in rats exposed to electric fields compared to control group. In addition, all latencies of VEP components were increased in the E18 group with respect to the E12 group. It is conceivable to suggest that EF-induced lipid peroxidation may play an important role in changes of VEP parameters.  相似文献   

9.
Air ions and direct current (DC) electric fields have been reported to exert subtle behavioral and biological effects on rodents and humans. These effects often appear inconsistent, yet there have been few attempts to resolve these inconsistencies by experimental replication. Rats exposed to negatively or positively charged air ions over a wide range of concentrations and exposure periods have been reported to show alterations in their level of locomotor activity. In this study, locomotor activity of Sprague-Dawley rats was quantified during exposure to either unipolar air ions and DC fields of the same polarity or DC fields alone. Both polarities were studied. Air ion concentrations were 5.0 X 10(3), DC fields were 3 kV/m, and exposures lasted 2, 18, or 66 h. In one experiment rats were exposed to DC fields of 12 kV/m. No exposure condition exerted any effect on locomotor activity or rearing behavior. In addition, no behavioral perturbations were observed after the onset of any of the exposure conditions, suggesting that the rats may have failed to detect the altered environment.  相似文献   

10.
DNA damage was induced in isolated human peripheral lymphocytes by exposure at 5 Gy to 60Co radiation. Cells were permitted to repair the DNA damage while exposed to 60-Hz fields or while sham-exposed. Exposed cells were subjected to magnetic (B) or electric (E) fields, alone or in combination, throughout their allotted repair time. Repair was stopped at specific times, and the cells were immediately lysed and then analyzed for the presence of DNA single-strand breaks (SSB) by the alkaline-elution technique. Fifty to 75 percent of the induced SSB were repaired 20 min after exposure, and most of the remaining damage was repaired after 180 min. Cells were exposed to a 60-Hz ac B field of 1 mT; an E field of 1 or 20 V/m; or combined E and B fields of 0.2 V/m and 0.05 mT, 6 V/m and 0.6 mT, or 20 V/m and 1 mT. None of the exposures was observed to affect significantly the repair of DNA SSB.  相似文献   

11.
Sprague-Dawley male rats, maintained in a 14:10 h light:dark cycl were exposed for 30 days (starting at 56 days of age) to a 65 kV/m, 60 Hz electric field or to a sham field for 20 h/day beginning at dark onset. Pineal N-acetyltransferase (NAT), hydroxy-indole-o-methyl transferase (HIOMT), and melatonin as well as serum melatonin were assayed. Preliminary data on unexposed animals indicated that samples obtained 4 h into the dark period would reveal either a phase delay or depression in circadian melatonin synthesis and secretion. Exposure to electric fields for 30 days did not alter the expected nighttime increase in pineal NAT, HIOMT, or melatonin. Serum melatonin levels were also increased at night, but the electric field-exposed animals had lower levels than the sham-exposed animals. Concurrent exposure to red light and the electric field or exposure to the electric field at a different time of the day-night period did not reduce melatonin synthesis. These data do not support the hypothesis that chronic electric field exposure reduces pineal melatonin synthesis in young adult male rats. However, serum melatonin levels were reduced by electric field exposure, suggesting the possibility that degradation or tissue uptake of melatonin is stimulated by exposure to electric fields. © 1994 Wiley-Liss, Inc.  相似文献   

12.
Consistent and independently replicated laboratory evidence to support a causative relationship between environmental exposure to extremely low-frequency electromagnetic fields (EMFs) at power line frequencies and the associated increase in risk of childhood leukemia has not been obtained. In particular, although gene expression responses have been reported in a wide variety of cells, none has emerged as robust, widely replicated effects. DNA microarrays facilitate comprehensive searches for changes in gene expression without a requirement to select candidate responsive genes. To determine if gene expression changes occur in white blood cells of volunteers exposed to an ELF-EMF, each of 17 pairs of male volunteers age 20-30 was subjected either to a 50 Hz EMF exposure of 62.0 ± 7.1 μT for 2 h or to a sham exposure (0.21 ± 0.05 μT) at the same time (11:00 a.m. to 13:00 p.m.). The alternative regime for each volunteer was repeated on the following day and the two-day sequence was repeated 6 days later, with the exception that a null exposure (0.085 ± 0.01 μT) replaced the sham exposure. Five blood samples (10 ml) were collected at 2 h intervals from 9:00 to 17:00 with five additional samples during the exposure and sham or null exposure periods on each study day. RNA samples were pooled for the same time on each study day for the group of 17 volunteers that were subjected to the ELF-EMF exposure/sham or null exposure sequence and were analyzed on Illumina microarrays. Time courses for 16 mammalian genes previously reported to be responsive to ELF-EMF exposure, including immediate early genes, stress response, cell proliferation and apoptotic genes were examined in detail. No genes or gene sets showed consistent response profiles to repeated ELF-EMF exposures. A stress response was detected as a transient increase in plasma cortisol at the onset of either exposure or sham exposure on the first study day. The cortisol response diminished progressively on subsequent exposures or sham exposures, and was attributable to mild stress associated with the experimental protocol.  相似文献   

13.
White-footed mice, Peromyscus leucopus, were exposed to 60-Hz electric fields to study the relationship between field strength and three measures of the transient arousal response previously reported to occur with exposures at 100 kV/m. Five groups of 12 mice each were given a series of four 1-h exposures, separated by an hour, with each group exposed at one of the following field strengths: 75, 50, 35, 25, and 10 kV/m; 8 additional mice were sham-exposed with no voltage applied to the field generator. All mice were experimentally naive before the start of the experiment, and all exposures occurred during the inactive (lights-on) phase of the circadian cycle. The first exposure produced immediate increases in arousal measures, but subsequent exposures had no significant effect on any measure. These arousal responses were defined by significant increases of gross motor activity, carbon dioxide production, and oxygen consumption, and were frequently recorded with field strengths of 50 kV/m or higher. Significant arousal responses rarely occurred with exposures at lower field strengths. Responses of mice exposed at 75 and 50 kV/m were similar to previously described transient arousal responses in mice exposed to 100-kV/m electric fields. Less than half of the mice in each of the field strength groups below 50 kV/m showed arousal responses based on Z (standard) scores, but the arousals of the mice that did respond were similar to those of mice exposed at higher field strengths. Polynomial regression was used to calculate the field strength producing the greatest increases for each of the arousal measures. The results show that the amplitude of the transient arousal response is related to the strength of the electric field, but different measures of arousal may have different relationships to field strength.  相似文献   

14.
This investigation studied the effects of 50-Hz electric and magnetic fields on the pulse rate and blood pressure in humans. Electrocardiograms (ECG) and the blood pressure of 41 male volunteers were recorded using ambulatory methods. Twenty-six subjects were measured in and outside real fields and 15 subjects in and outside `sham' fields. The results of the ECG recordings have been presented earlier. This article deals with the analysis of the blood pressure measurements. Measurement took 3 hrs. First, the subjects spent 1 h outside the fields, then 1 h in real or `sham' fields, followed by 1 h outside the fields. The electric field strength varied from 3.5 to 4.3 kV/m and the magnetic flux density from 1.4 to 6.6 μT. When analysing the blood pressure, which was measured with a non-invasive cuff method, it could not be shown that the fields (<4.3 kV/m and <6.6 μT) affected diastolic or systolic blood pressure. Received: 6 June 1994 / Accepted in revised form: 11 March 1996  相似文献   

15.
Human umbilical vein endothelial cells were exposed to sinusoidal electric fields of 0.3 or 30 kV/m, 50 Hz, for 24 h. Changes in intracellular calcium concentration ([Ca(2+)](i)) induced by ATP-stimulation in the absence of extracellular Ca(2+) were observed in individual cells. No differences were observed between the exposure and sham-exposure groups in [Ca(2+)](i) resting level before ATP-stimulation, or in the [Ca(2+)](i) peak levels induced by stimulation. However, the duration of the initial transients in [Ca(2+)](i) following an ATP stimulus was significantly prolonged by exposure to a 30 kV/m field. The inositol trisphosphate receptor inhibitor, xestospongin C, inhibited the ATP-induced elevation in [Ca(2+)](i) in both the exposure and sham-exposure groups. The ATP-receptor P2Y appeared to play an important role in the increase of [Ca(2+)](i). The present results suggest that an extremely low-frequency electric field affects the function of vascular endothelial cells by a mechanism involving activation of P2Y.  相似文献   

16.
In vivo effects of Static Electric and ELF Magnetic and Electric fields have been carried out for more than 20 years in the Bioelectromagnetic Laboratory at the Biophysics Department of the Medical Faculty of Gazi University. In this article, the results of in vivo ELF Electric field studies are presented as a review. Static and 50 Hz ELF (Extremely Low Frequency) Electric (E) fields effects on free radical synthesis, antioxidant enzyme level, and collagen synthesis were analyzed on tissues of guinea pigs, such as brain, liver, lung, kidney, spleen, testis, and plasma. Animals were exposed to static and ELF electric fields with intensities ranging from 0.3 kV/m to 1.9 kV/m in vertical and horizontal directions. Exposure periods were 1, 3, 5, 7, and 10 days. Electric fields were generated from a specially designed parallel plate capacitor system. The results indicate that the effects of electric fields on the tissues studied depend significantly on the type and magnitude of electric field and exposure period.  相似文献   

17.
ABSTRACT

In our previous study, the developmental effects of extremely low-frequency electric fields (ELF-EF) on visual and somatosensory evoked potentials in adult rats were studied. There is no study so far examining the effects of 50 Hz electric field (EF) on mismatch negativity (MMN) recordings after exposure of rats during development. Therefore, our present study aimed to investigate MMN and oxidative brain damage in rats exposed to EF (12 kV/m, 1 h/day). Rats were divided into four groups, namely control (C), prenatal (Pr), postnatal (Po), and prenatal+postnatal (PP). Pregnant rats of Pr and PP groups were exposed to EF during pregnancy. Following birth, rats of PP and Po groups were exposed to EF for three months. After exposure to EF, MMN was recorded by electrodes positioned stereotaxically to the surface of the dura, and then brain tissues were removed for histological and biochemical analyses. The MMN amplitude was higher to deviant tones than to standard tones. It was decreased in all experimental groups compared with the C group. 4-Hydroxy-2-nonenal (4-HNE) levels were significantly increased in the Po group with respect to the C group, whereas they were significantly decreased in the PP group compared with Pr and Po groups. Protein carbonyl levels were significantly decreased in the PP group compared with C, Pr, and Po groups. EF decreased MMN amplitudes were possibly induced by lipid peroxidation.  相似文献   

18.
The occupational exposure to electric and magnetic fields during various work tasks at seven 110 kV substations in Finland's Tampere region was studied. The aim was to investigate if the action values (10 kV/m for the E‐field and 500 µT for the B‐field) of the EU Directive 2004/40/EC were exceeded. Electric and magnetic fields were measured during the following work tasks: (1) walking or operating devices on the ground; (2) working from a service platform; (3) working around the power transformer on the ground or using a ladder; and (4) changing a bulb from a man hoist. In work task 2 “working from a service platform” the measured electric field (maximum value 16.6 kV/m) exceeded 10 kV/m in three cases. In the future it is important to study if the limit value (10 mA/m2) of Directive 2004/40/EC is exceeded at 110 kV substations. The occupational 500 µT action value of the magnetic flux density field (B‐field) was not exceeded in any working situation. Bioelectromagnetics 31:252–254, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

19.
This investigation studied the effects of 50 Hz electric and magnetic fields on the pulse rate of the human heart. The ECG (electrocardiograms) of 41 male volunteers were recorded with a Holter recorder. Twenty-six subjects were measured in and outside real fields, and 15 subjects were measured in and outside “sham” fields. The blood pressure and EEG (electroencephalogram) were also measured, but this article presents only the results of ECG recordings. The measurements took 3 h. The subjects were first sitting for 1 h outside the fields, then 1 h in the real or “sham” fields, and then, again, 1 h outside the fields. The electric field strength varied from 3.5 to 4.3 kV/m and the magnetic flux density from 1.4 to 6.6 μT. An analysis of the ECG recordings showed that the subjects' pulse rates were the same in and outside the fields. No response occurred when the subjects were exposed to real or “sham” fields. © 1994 Wiley-Liss, Inc.  相似文献   

20.
Electrosurgical units (ESU) are widely used in medical health services. By applying sinusoidal or pulsed voltage in the frequency range of 0.3–5 MHz to the electrode tip, the desired mixture of coagulation and cutting are achieved. Due to the high voltage and current in the cable, strong electromagnetic fields appear near the ESU. The surgeon and others inside the operating room such as nurses, anesthesiologists, etc., will be highly exposed to these fields. The stray fields surrounding the ESU have previously been measured, but now a deeper analysis has been made of the curve shape of the field and the implication of this when assessing exposure from a commonly used ESU in accordance with the International Commission on Non‐Ionizing Radiation Protection (ICNIRP) guidelines. The result showed that for some of the modes, especially those using high‐pulsed voltage with only a few sinusoidal periods, the E‐field close to the cable could reach linear spatially averaged values of 20 kV/m compared to the 2.1 kV/m stated in ICNIRP guidelines. Assessing the E‐ and B‐field from ESU is not straightforward since in this frequency range, both induced current density and specific absorption rate are restricted by the ICNIRP guidelines. Nevertheless, work needs to be done to reduce the stray fields from ESU. Bioelectromagnetics 31:513–518, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号