首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The goal of this study is to quantify changes in knee joint contact behavior following varying degrees of the medial partial meniscectomy. A previously validated 3D finite element model was used to simulate 11 different meniscectomies. The accompanying changes in the contact pressure on the superior surface of the menisci and tibial plateau were quantified as was the axial strain in the menisci and articular cartilage. The percentage of medial meniscus removed was linearly correlated with maximum contact pressure, mean contact pressure, and contact area. The lateral hemi-joint was minimally affected by the simulated medial meniscectomies. The location of maximum strain and location of maximum contact pressure did not change with varying degrees of partial medial meniscectomy. When 60% of the medial meniscus was removed, contact pressures increased 65% on the remaining medial meniscus and 55% on the medial tibial plateau. These data will be helpful for assessing potential complications with the surgical treatment of meniscal tears. Additionally, these data provide insight into the role of mechanical loading in the etiology of post-meniscectomy osteoarthritis.  相似文献   

2.
Knee osteoarthritis (OA) is believed to result from high levels of contact stresses on the articular cartilage and meniscus after meniscal damage. This study investigated the effect of meniscal tears and partial meniscectomies on the peak compressive and shear stresses in the human knee joint. An elaborate three-dimensional finite element model of knee joint including bones, articular cartilages, menisci and main ligaments was developed from computed tomography and magnetic resonance imaging images. This model was used to model four types of meniscal tears and their resultant partial meniscectomies and analysed under an axial 1150 N load at 0° flexion. Three different conditions were compared: a healthy knee joint, a knee joint with medial meniscal tears and a knee joint following partial meniscectomies. The numerical results showed that each meniscal tear and its resultant partial meniscectomy led to an increase in the peak compressive and shear stresses on the articular cartilages and meniscus in the medial knee compartment, especially for partial meniscectomy. Among the four types of meniscal tears, the oblique tear resulted in the highest values of the peak compressive and shear stresses. For the four partial meniscectomies, longitudinal meniscectomy led to the largest increase in these two stresses. The lateral compartment was minimally affected by all the simulations. The results of this study demonstrate meniscal tear and its resultant partial meniscectomy has a positive impact on the maintenance of high levels of contact stresses, which may improve the progression of knee OA, especially for partial meniscectomy. Surgeons should adopt a prudent strategy to preserve the greatest amount of meniscus possible.  相似文献   

3.
Partial meniscectomy is believed to change the biomechanics of the knee joint through alterations in the contact of articular cartilages and menisci. Although fluid pressure plays an important role in the load support mechanism of the knee, the fluid pressurization in the cartilages and menisci has been ignored in the finite element studies of the mechanics of meniscectomy. In the present study, a 3D fibril-reinforced poromechanical model of the knee joint was used to explore the fluid flow dependent changes in articular cartilage following partial medial and lateral meniscectomies. Six partial longitudinal meniscectomies were considered under relaxation, simple creep, and combined creep loading conditions. In comparison to the intact knee, partial meniscectomy not only caused a substantial increase in the maximum fluid pressure but also shifted the location of this pressure in the femoral cartilage. Furthermore, these changes were positively correlated to the size of meniscal resection. While in the intact joint, the location of the maximum fluid pressure was dependent on the loading conditions, in the meniscectomized joint the location was predominantly determined by the site of meniscal resection. The partial meniscectomy also reduced the rate of the pressure dissipation, resulting in even larger difference between creep and relaxation times as compared to the case of the intact knee. The knee joint became stiffer after meniscectomy because of higher fluid pressure at knee compression followed by slower pressure dissipation. The present study indicated the role of fluid pressurization in the altered mechanics of meniscectomized knees.  相似文献   

4.
The menisci play an important role in load distribution, load bearing, joint stability, lubrication, and proprioception. Partial meniscectomy has been shown to result in changes in the kinematics and kinetics at the knee during gait that can lead to progressive meniscal degeneration. This study examined changes in the strains within the menisci associated with kinematic and kinetic changes during the gait cycle. The gait changes considered were a 5 deg shift toward external rotation of the tibia with respect to the femur and an increased medial-lateral load ratio representing an increased adduction moment. A finite element model of the knee was developed and tested using a cadaveric specimen. The cadaver was placed in positions representing heel-strike and midstance of the normal gait, and magnetic resonance images were taken. Comparisons of the model predictions to boundaries digitized from images acquired in the loaded states were within the errors produced by a 1 pixel shift of either meniscus. The finite element model predicted that an increased adduction moment caused increased strains of both the anterior and posterior horns of the medial meniscus. The lateral meniscus exhibited much lower strains and had minimal changes under the various loading conditions. The external tibial rotational change resulted in a 20% decrease in the strains in the posterior medial horn and increased strains in the anterior medial horn. The results of this study suggest that the shift toward external tibial rotation seen clinically after partial medial meniscectomy is not likely to cause subsequent degenerative medial meniscal damage, but the consequence of this kinematic shift on the pathogenesis of osteoarthritis following meniscectomy requires further consideration.  相似文献   

5.
In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements are subjects of current interest and investigation. The objectives of the current study were to (1) determine whether a transversely isotropic, linearly elastic, homogeneous material model of the meniscal tissue is necessary to achieve a normal contact pressure distribution on the tibial plateau, (2) determine which material and boundary condition (attachments) parameters affect the contact pressure distribution most strongly, and (3) set tolerances on these parameters to restore the contact pressure distribution to within a specified error. To satisfy these objectives, a finite element model of the tibio-femoral joint of a human cadaveric knee (including both menisci) was used to study the contact pressure distribution on the tibial plateau. To validate the model, the contact pressure distribution on the tibial plateau was measured experimentally in the same knee used to create the model. Within physiologically reasonable bounds on five material parameters and four attachment parameters associated with a meniscal replacement, an optimization was performed under 1200 N of compressive load on the set of nine parameters to minimize the difference between the experimental and model results. The error between the experimental and model contact variables was minimized to 5.4%. The contact pressure distribution of the tibial plateau was sensitive to the circumferential modulus, axial/radial modulus, and horn stiffness, but relatively insensitive to the remaining six parameters. Consequently, both the circumferential and axial/radial moduli are important determinants of the contact pressure distribution, and hence should be matched in the design and/or selection of meniscal replacements. In addition, during surgical implantation of a meniscal replacement, the horns should be attached with high stiffness bone plugs, and the attachments of the transverse ligament and deep medial collateral ligament should be restored to minimize changes in the contact pressure distribution, and thereby possibly prevent the degradation of articular cartilage.  相似文献   

6.
Studies of the load transfer role of the meniscus have been limited to static experimental and analytical approaches. The objective of this study was to develop an experimental technique to allow the contact pressures on the tibial plateau of cadaveric knees to be measured under dynamic physiological loads. Accordingly, we adapted a load-controlled knee joint simulator to accept a cadaveric sheep knee, programmed the simulator with sheep gait kinematics data, and utilized a pressure sensor array to measure the contact pressure distribution on the lateral tibial plateau during gait. The technique was applied to six sheep knees that were tested intact and after meniscectomy. Meniscectomy resulted in a 267% increase in average contact pressure, a 117% increase in peak contact pressure, and an 80% decrease in contact area, all measured at the point of maximum peak contact stress in the gait cycle. It is envisaged that the experimental model herein developed will allow for the screening of candidate materials prior to more expensive and time-consuming animal models.  相似文献   

7.
A validated three-dimensional computational model of a human knee joint   总被引:7,自引:0,他引:7  
This paper presents a three-dimensional finite element tibio-femoral joint model of a human knee that was validated using experimental data. The geometry of the joint model was obtained from magnetic resonance (MR) images of a cadaveric knee specimen. The same specimen was biomechanically tested using a robotic/universal force-moment sensor (UFS) system and knee kinematic data under anterior-posterior tibial loads (up to 100 N) were obtained. In the finite element model (FEM), cartilage was modeled as an elastic material, ligaments were represented as nonlinear elastic springs, and menisci were simulated by equivalent-resistance springs. Reference lengths (zero-load lengths) of the ligaments and stiffness of the meniscus springs were estimated using an optimization procedure that involved the minimization of the differences between the kinematics predicted by the model and those obtained experimentally. The joint kinematics and in-situ forces in the ligaments in response to axial tibial moments of up to 10 Nm were calculated using the model and were compared with published experimental data on knee specimens. It was also demonstrated that the equivalent-resistance springs representing the menisci are important for accurate calculation of knee kinematics. Thus, the methodology developed in this study can be a valuable tool for further analysis of knee joint function and could serve as a step toward the development of more advanced computational knee models.  相似文献   

8.
As a step towards developing a finite element model of the knee that can be used to study how the variables associated with a meniscal replacement affect tibio-femoral contact, the goals of this study were 1) to develop a geometrically accurate three-dimensional solid model of the knee joint with special attention given to the menisci and articular cartilage, 2) to determine to what extent bony deformations affect contact behavior, and 3) to determine whether constraining rotations other than flexion/extension affects the contact behavior of the joint during compressive loading. The model included both the cortical and trabecular bone of the femur and tibia, articular cartilage of the femoral condyles and tibial plateau, both the medial and lateral menisci with their horn attachments, the transverse ligament, the anterior cruciate ligament, and the medial collateral ligament. The solid models for the menisci and articular cartilage were created from surface scans provided by a noncontacting, laser-based, three-dimensional coordinate digitizing system with an root mean squared error (RMSE) of less than 8 microns. Solid models of both the tibia and femur were created from CT images, except for the most proximal surface of the tibia and most distal surface of the femur which were created with the three-dimensional coordinate digitizing system. The constitutive relation of the menisci treated the tissue as transversely isotropic and linearly elastic. Under the application of an 800 N compressive load at 0 degrees of flexion, six contact variables in each compartment (ie., medial and lateral) were computed including maximum pressure, mean pressure, contact area, total contact force, and coordinates of the center of pressure. Convergence of the finite element solution was studied using three mesh sizes ranging from an average element size of 5 mm by 5 mm to 1 mm by 1 mm. The solution was considered converged for an average element size of 2 mm by 2 mm. Using this mesh size, finite element solutions for rigid versus deformable bones indicated that none of the contact variables changed by more than 2% when the femur and tibia were treated as rigid. However, differences in contact variables as large as 19% occurred when rotations other than flexion/extension were constrained. The largest difference was in the maximum pressure. Among the principal conclusions of the study are that accurate finite element solutions of tibio-femoral contact behavior can be obtained by treating the bones as rigid. However, unrealistic constraints on rotations other than flexion/extension can result in relatively large errors in contact variables.  相似文献   

9.
The knee meniscus and hip labrum appear to be important for joint health, but the mechanisms by which these structures perform their functions are not fully understood. The fluid phase of articular cartilage provides compressive stiffness and aids in maintaining a low friction articulation. Healthy fibrocartilage, the tissue of meniscus and labrum, has a lower fluid permeability than articular cartilage. In this study we hypothesized that an important function of the knee meniscus and the hip labrum is to augment fluid retention in the articular cartilage of a mechanically loaded joint. Axisymmetric hyperporoelastic finite element models were analyzed for an idealized knee and an idealized hip. The results indicate that the meniscus maintained fluid pressure and inhibited fluid exudation in knee articular cartilage. Similar, but smaller, effects were seen with the labrum in the hip. Increasing the fibrocartilage permeability relative to that of articular cartilage gave a consolidation rate and loss of fluid load support comparable to that predicted by meniscectomy or labrectomy. The reduced articular cartilage fluid pressure that was calculated for the joint periphery is consistent with patterns of endochondral ossification and osteophyte formation in knee and hip osteoarthritis. High articular central strains and loss of fluid load support after meniscectomy could lead to fibrillation. An intact low-permeability fibrocartilage is important for limiting fluid exudation from articular cartilage in the hip and knee. This may be an important aspect of the role of fibrocartilage in protecting these joints from osteoarthritis.  相似文献   

10.
A 3D knee model was developed in order to evaluate the mechanical behaviour during flexion of condylar-type knee prosthesis. Based on the total energy minimization principle, it takes into account the articular surfaces (the tibial surface being deformable), the body weight, and the patello femoral joint. It generates the kinematics of the joint, the motion of the centre of contact, the quadriceps forces, the pressure distribution on the tibial plateau, and ligament lengths and forces between 0 and 120 degrees of flexion. The results for ten digitized knees and the commercially available prostheses are presented. They are in general agreement with experimental results published in the literature. It is concluded that this computer program may be, within its limitations, a useful tool in the preliminary evaluation of new condylar-type knee prosthesis designs.  相似文献   

11.
Loss of charged proteoglycans in the knee meniscus, which aid in the support of compressive loads by entraining water, is an effect of degeneration and is often associated with osteoarthritis. In healthy menisci, proteoglycan content is highest in the inner white zone and decreases towards the peripheral red zone. We hypothesized that loss of proteoglycans would reduce both osmotic swelling and compressive stiffness, spatially localized to the avascular white zone of the meniscus. This hypothesis was tested by targeted enzymatic digestion of proteoglycans using hyaluronidase in intact cervine medial menisci. Mechanics were quantified by creep indentation on the femoral surface. Osmotic swelling changes were assessed by measuring collagen fiber crimp period in the radial-axial plane in the lamellar layer along both the tibial and femoral contacting surfaces. All measurements were made in the inner, middle, and outer zones of the anterior, central, and posterior regions. Mechanical measurements showed variation in creep behavior with anatomical location, along with spatially uniform decreases in viscosity (average of 21%) and creep stiffness (average of 15%) with hyaluronidase treatment. Lamellar collagen crimp period was significantly decreased (average of 27%) by hyaluronidase, indicating a decrease in osmotic swelling, with the largest decreases seen in locations with the highest proteoglycan content. Taken together, these results suggest that while proteoglycans have localized effects on meniscus swelling, the resulting effect on compressive properties is distributed throughout the tissue.  相似文献   

12.
Injuries to the anterior cruciate ligament (ACL) and menisci commonly lead to early onset osteoarthritis. Treatments that can restore normative cartilage loading patterns may mitigate the risk of osteoarthritis, though it is unclear whether such a goal is achievable through conservative rehabilitation. We used musculoskeletal simulation to predict cartilage and ligament loading patterns during walking in intact, ACL deficient, menisci deficient, and ACL-menisci deficient knees. Stochastic simulations with varying coordination strategies were then used to test whether neuromuscular control could be modulated to restore normative knee mechanics in the pathologic conditions. During early stance, a 3 mm increase in anterior tibial translation was predicted in the ACL deficient knee. Mean cartilage contact pressure increased by 18% and 24% on the medial and lateral plateaus, respectively, in the menisci deficient knee. Variations in neuromuscular coordination were insufficient to restore normative cartilage contact patterns in either the ACL or menisci deficient knees. Elevated cartilage contact pressures in the pathologic knees were observed in regions where cartilage wear patterns have previously been reported. These results suggest that altered cartilage tissue loading during gait may contribute to region-specific degeneration patterns, and that varying neuromuscular coordination in isolation is unlikely to restore normative knee mechanics.  相似文献   

13.
In the aim of bringing a contribution to role of the knee menisci and the functional connection between meniscal lesions and knee joint instability, four patients have been studied, who underwent arthroscopy for sub-acute tear of anterior cruciate ligament without clinical or morphological evidence of meniscal pathology. In these patients biopsies have been taken from one of the menisci and processed for the examination by the SEM. As control, meniscal fragments from two healthy knees have been studied from patients who underwent amputation at thigh for accidental trauma with irreparable lesion of femoral artery. In patients affected by ligamentous tear, on the meniscal surface a lot of deposited material appears, as well as many microlesions as clefts or cracking and distortion of superficial collagenous fibers. All described alteration are more evident in the central portion of menisci than in the anterior or posterior horns. The above mentioned patterns suggest a strong correlation of the knee instability due to ligamentous lesions and meniscal degenerative process which would onset before its clinical or macroscopical evidence.  相似文献   

14.
The function of articular cartilage as an avascular tissue is mainly served by collagen type II and proteoglycan molecules. Within this matrix homeostasis between production and breakdown of the matrix is exceptionally sensitive.The current study was conducted to identify regional differences in specific alterations in cartilage composition during the osteoarthritic process of the human knee joint. Therefor the changes in the expression of the key molecules of the extracellular matrix were measured in dependence of the anatomical side (femoral vs tibial) and associated with immunohistochemistry and quantitative measurement.60 serial osteochondral femoral condyle and the tibial plateau samples of patients undergoing implantation of total knee endoprosthesis of areas showing mild (Group A, macroscopically ICRS grade 1b) respectively advanced (Group B, macroscopically ICRS grade 3a/3b) (30 each) osteoarthritis according to the histological-histochemical grading system (HHGS) were compared with 20 healthy biopsies with immunohistochemistry and histology. We quantified our results on the gene expression of collagen type I and II and aggrecan with the help of real-time (RT)-PCR. Proteoglycan content was measured colorometrically.In group A slightly increased colour intensity was found for collagen II in deeper layers, suggesting a persisting but initially still intact repair process. But especially on the medial tibia plateau the initial Col II increase in gene expression is followed by a decrease leading to the lowest over all Col II expression on the medial plateau, here especially in the central part. There in late stage diseases the collagen type I expression was also more pronounced. Markedly decreased safranin O staining intensity was observed in the radial zone and less reduced intensity in the transitional zone with loss of zonal anatomy in 40% of the specimens in group A and all specimens in group B. Correlation between colorometrically analysed proteoglycan GAG content and aggrecan Real Time PCR is mainly weak.Tibial and femoral cartilage in contrast to patellar cartilage both are preferential exposed to compressive stresses, but presence of menisci affects the load distribution at the tibial side, which creates varying conditions for the different cartilage surfaces in the knee.As directly measured Poissońs ratio in tibial cartilage is higher but Youn?s modulus is lower than in femoral cartilage, different resulting feedback amplification loops interact with proceeding cartilage damage. The initial loss of aggrecan may support Matrix metalloproteinases (Mmps) in the access to the collagen network and the considerably differing mechanical properties at both joint surfaces result in varying increased synthesis and release of matrix degrading enzymes.The present study has identified a selection of events which reflect the response of cartilage structure and composite, chondrocytes itself and their productivity to changes in mechanical stress depending on the anatomical site.  相似文献   

15.
The spatial distribution and pattern of local contact stresses within the knee joint during activities of daily living have not been fully investigated. The objective of this study was to determine if common contact stress patterns exist on the tibial plateaus of human knees during simulated gait. To test this hypothesis, we developed a novel normalized cross-correlation (NCC) algorithm and applied it to the contact stresses on the tibial plateaus of 12 human cadaveric knees subjected to multi-directional loads mimicking gait. The contact stress profiles at different locations on the tibial plateaus were compared, where regions with similar contact stress patterns were identified across specimens. Three consistent regional patterns were found, among them two most prominent contact stress patterns were shared by 9–12 of all the knees and the third pattern was shared by 6–8 knees. The first pattern was located at the posterior aspect of the medial tibial plateau and had a single peak stress that occurred during the early stance phase. The second pattern was located at the central-posterior aspects of the lateral plateau and consisted of two peak stresses coincident with the timing of peak axial force at early and late stance. The third pattern was found on the anterior aspect of cartilage-to-cartilage contact region on the medial plateau consisted of double peak stresses. The differences in the location and profile of the contact stress patterns suggest that the medial and lateral menisci function to carry load at different points in the gait cycle: with the posterior aspect of the medial meniscus consistently distributing load only during the early phase of stance, and the posterior aspect of the lateral meniscus consistently distributing load during both the early and late phases of stance. This novel approach can help identify abnormalities in knee contact mechanics and provide a better understanding of the mechanical pathways leading to post-traumatic osteoarthritis.  相似文献   

16.
The menisci of the knee are structures integral to the long term health of the knee joint. The primary function of these tissues is to distribute load across the tibiofemoral joint by increasing the congruency of the joint, thereby decreasing the resultant stress experienced by the articular cartilages. The menisci also play a secondary role in stabilizing the joint, particularly in the anterior cruciate ligament deficient knee, and also have roles in joint lubrication and proprioception. Also, an oft-cited role of this tissue is that of a shock absorber. We will review the literature supporting this shock absorption paradigm and describe the limitations and errors in the conclusions made by these studies. Consequently, we will show that the literature is inconclusive with no support for the shock absorption paradigm, which should therefore not be stated as a function of the menisci. We will describe how one of the three articles in support of this paradigm actually could be interpreted to the contrary and support the idea that the menisci may play no significant role in shock absorption at the knee at all, with the two remaining papers being inconclusive.  相似文献   

17.
The anterior-posterior (AP) stability of the knee is an important aspect of functional performance. Studies have shown that the stability increases when compressive loads are applied, as indicated by reduced laxity, but the mechanism has not been fully explained. A test rig was designed which applied combinations of AP shear and compressive forces, and measured the AP displacements relative to the neutral position. Five knees were evaluated at compressive loads of 0, 250, 500, and 750 N, with the knee at 15° flexion. At each load, three cycles of shear force at ±100 N were applied. For the intact knee under load, the posterior tibial displacement was close to zero, due to the upward slope of the anterior medial tibial surface. The soft tissues were then resected in sequence to determine their role in AP laxity. After anterior cruciate ligament (ACL) resection, the anterior tibial displacement increased significantly even under load, highlighting its importance in stability. Meniscal resection further increased displacement but also the vertical displacement increased, implying the meniscus was providing a buffering effect. The PCL had no effect on any of the displacements under load. Plowing cartilage deformation and surface friction were negligible. This work highlighted the particular importance of the upward slope of the anterior medial tibial surface and the ACL to AP knee stability under load. The results are relevant to the design of total knees which reproduce anatomic knee stability behavior.  相似文献   

18.
Manual segmentation of articular cartilage from knee joint 3D magnetic resonance images (MRI) is a time consuming and laborious task. Thus, automatic methods are needed for faster and reproducible segmentations. In the present study, we developed a semi-automatic segmentation method based on radial intensity profiles to generate 3D geometries of knee joint cartilage which were then used in computational biomechanical models of the knee joint. Six healthy volunteers were imaged with a 3T MRI device and their knee cartilages were segmented both manually and semi-automatically. The values of cartilage thicknesses and volumes produced by these two methods were compared. Furthermore, the influences of possible geometrical differences on cartilage stresses and strains in the knee were evaluated with finite element modeling. The semi-automatic segmentation and 3D geometry construction of one knee joint (menisci, femoral and tibial cartilages) was approximately two times faster than with manual segmentation. Differences in cartilage thicknesses, volumes, contact pressures, stresses, and strains between segmentation methods in femoral and tibial cartilage were mostly insignificant (p > 0.05) and random, i.e. there were no systematic differences between the methods. In conclusion, the devised semi-automatic segmentation method is a quick and accurate way to determine cartilage geometries; it may become a valuable tool for biomechanical modeling applications with large patient groups.  相似文献   

19.
Previous models of cortical bone adaptation, in which loading is imposed on the bone, have estimated the strains in the tissue using strain gauges, analytical beam theory, or finite element analysis. We used digital image correlation (DIC), tracing a speckle pattern on the surface of the bone during loading, to determine surface strains in a murine tibia during compressive loading through the knee joint. We examined whether these surface strains in the mouse tibia are modified following two weeks of load-induced adaptation by comparison with contralateral controls. Results indicated non-uniform strain patterns with isolated areas of high strain (0.5%), particularly on the medial side. Strain measurements were reproducible (standard deviation of the error 0.03%), similar between specimens, and in agreement with strain gauge measurements (between 0.1 and 0.2% strain). After structural adaptation, strains were more uniform across the tibial surface, particularly on the medial side where peak strains were reduced from 0.5% to 0.3%. Because DIC determines local strains over the entire surface, it will provide a better understanding of how strain stimulus influences the bone response during adaptation.  相似文献   

20.
Anterior tibial loading is a major factor involved in the anterior cruciate ligament (ACL) injury mechanism during ski impact landing. We sought to investigate the direct contribution of axial impact compressive load to anterior tibial load during simulated ski landing impact of intact knee joints without quadriceps activation. Twelve porcine knee specimens were procured. Four specimens were used as non-impact control while the remaining eight were mounted onto a material-testing system at 70° flexion and subjected to simulated landing impact, which was successively repeated with incremental actuator displacement. Four specimens from the impacted group underwent pre-impact MRI for tibial plateau angle measurements while the other four were subjected to histology and microCT for cartilage morphology and volume assessment. The tibial plateau angles ranged from 29.4 to 38.8°. There was a moderate linear relationship (Y=0.16X; R2=0.64; p<0.001) between peak axial impact compressive load (Y) and peak anterior tibial load (X). The anterior and posterior regions in the impacted group sustained surface cartilage fraying, superficial clefts and tidemark disruption, compared to the control group. MicroCT scans displayed visible cartilage deformation for both anterior and posterior regions in the impacted group. Due to the tibial plateau angle, increased axial impact compressive load can directly elevate anterior tibial load and hence contribute to ACL failure during simulated landing impact. Axial impact compressive load resulted in shear cartilage damage along anterior–posterior tibial plateau regions, due to its contribution to anterior tibial loading. This mechanism plays an important role in elevating ACL stress and cartilage deformation during impact landing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号