首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this work, we examine the dynamics of fluid flow in a mechanical heart valve when the solid inertia and leaflet compliance are important. The fluid is incompressible and Newtonian, and the leaflet is an incompressible neo-Hookean material. In the case of an inertialess leaflet, we find that the maximum valve opening angle and the time that the valve remains closed increase as the shear modulus of the leaflet decreases. More importantly, the regurgitant volume decreases with decreasing shear modulus. When we examined the forces exerted on the leaflet, we found that the downward motion of the leaflet is initiated by a vertical force exerted on its right side and, later on, by a vertical force exerted on the top side of the leaflet. In the case of solid inertia, we find that the maximum valve opening angle and the regurgitant volume are larger than in the case of an inertialess leaflet. These results highlight the importance of solid compliance in the dynamics of blood flow in a mechanical heart valve. More importantly, they indicate that mechanical heart valves with compliant leaflets may have smaller regurgitant volumes and smaller shear stresses than the ones with rigid leaflets.  相似文献   

2.
Estimation of regional tissue stresses in the functioning heart valve remains an important goal in our understanding of normal valve function and in developing novel engineered tissue strategies for valvular repair and replacement. Methods to accurately estimate regional tissue stresses are thus needed for this purpose, and in particular to develop accurate, statistically informed means to validate computational models of valve function. Moreover, there exists no currently accepted method to evaluate engineered heart valve tissues and replacement heart valve biomaterials undergoing valvular stresses in blood contact. While we have utilized mitral valve anterior leaflet valvuloplasty as an experimental approach to address this limitation, robust computational techniques to estimate implant stresses are required. In the present study, we developed a novel numerical analysis approach for estimation of the in-vivo stresses of the central region of the mitral valve anterior leaflet (MVAL) delimited by a sonocrystal transducer array. The in-vivo material properties of the MVAL were simulated using an inverse FE modeling approach based on three pseudo-hyperelastic constitutive models: the neo-Hookean, exponential-type isotropic, and full collagen–fiber mapped transversely isotropic models. A series of numerical replications with varying structural configurations were developed by incorporating measured statistical variations in MVAL local preferred fiber directions and fiber splay. These model replications were then used to investigate how known variations in the valve tissue microstructure influence the estimated ROI stresses and its variation at each time point during a cardiac cycle. Simulations were also able to include estimates of the variation in tissue stresses for an individual specimen dataset over the cardiac cycle. Of the three material models, the transversely anisotropic model produced the most accurate results, with ROI averaged stresses at the fully-loaded state of  432.6±46.5 kPa and 241.4±40.5 kPa in the radial and circumferential directions, respectively. We conclude that the present approach can provide robust instantaneous mean and variation estimates of tissue stresses of the central regions of the MVAL.  相似文献   

3.
Heterogeneities in structure and stress within heart valve leaflets are of significant concern to their functional physiology, as they affect how the tissue constituents remodel in response to pathological and non-pathological (e.g. exercise, pregnancy) alterations in cardiac function. Indeed, valve interstitial cells (VICs) are known to synthesize and degrade leaflet extracellular matrix (ECM) components in a manner specific to their local micromechanical environment. Quantifying local variations in ECM structure and stress is thus necessary to understand homeostatic valve maintenance as well as to develop predictive models of disease progression and post-surgical outcomes. In the aortic valve (AV), transmural variations in stress have previously been investigated by modeling the leaflet as a composite of contiguous but mechanically distinct layers. Based on previous findings about the bonded nature of these layers (Buchanan and Sacks, BMMB, 2014), we developed a more generalized structural constitutive model by treating the leaflet as a functionally graded material (FGM), whose properties vary continuously over the thickness. We informed the FGM model using high-resolution morphological measurements, which demonstrated that the composition and fiber structure change gradually over the thickness of the AV leaflet. For validation, we fit the model against an extensive database of whole-leaflet and individual-layer mechanical responses. The FGM model predicted large stress variations both between and within the leaflet layers at end-diastole, with low-collagen regions bearing significant radial stress. These novel results suggest that the continually varying structure of the AV leaflet has an important purpose with regard to valve function and tissue homeostasis.  相似文献   

4.
Simulated bioprosthetic heart valve deformation under quasi-static loading   总被引:1,自引:0,他引:1  
For more than 40 years, the replacement of diseased natural heart valves with prosthetic devices has dramatically extended the quality and length of the lives of millions of patients worldwide. However, bioprosthetic heart valves (BHV) continue to fail due to structural failure resulting from poor tissue durability and faulty design. Clearly, an in-depth understanding of the biomechanical behavior of BHV at both the tissue and functional prosthesis levels is essential to improving BHV design and to reduce rates of failure. In this study, we simulated quasi-static BHV leaflet deformation under 40, 80, and 120 mm Hg quasi-static transvalvular pressures. A Fung-elastic material model was used that incorporated material parameters and axes derived from actual leaflet biaxial tests and measured leaflet collagen fiber structure. Rigorous experimental validation of predicted leaflet strain field was used to validate the model results. An overall maximum discrepancy of 2.36% strain between the finite element (FE) results and experiment measurements was obtained, indicating good agreement between computed and measured major principal strains. Parametric studies utilizing the material parameter set from one leaflet for all three leaflets resulted in substantial variations in leaflet stress and strain distributions. This result suggests that utilization of actual leaflet material properties is essential for accurate BHV FE simulations. The present study also underscores the need for rigorous experimentation and accurate constitutive models in simulating BHV function and design.  相似文献   

5.
While providing nearly trouble-free function for 10-12 years, current bioprosthetic heart valves (BHV) continue to suffer from limited long-term durability. This is usually a result of leaflet calcification and/or structural degeneration, which may be related to regions of stress concentration associated with complex leaflet deformations. In the current work, a dynamic three-dimensional finite element analysis of a pericardial BHV was performed with a recently developed FE implementation of the generalized nonlinear anisotropic Fung-type elastic constitutive model for pericardial BHV tissues (W. Sun and M.S. Sacks, 2005, [Biomech. Model. Mechanobiol., 4(2-3), pp. 190-199]). The pericardial BHV was subjected to time-varying physiological pressure loading to compute the deformation and stress distribution during the opening phase of the valve function. A dynamic sequence of the displacements revealed that the free edge of the leaflet reached the fully open position earlier and the belly region followed. Asymmetry was observed in the resulting displacement and stress distribution due to the fiber direction and the anisotropic characteristics of the Fung-type elastic constitutive material model. The computed stress distribution indicated relatively high magnitudes near the free edge of the leaflet with local bending deformation and subsequently at the leaflet attachment boundary. The maximum computed von Mises stress during the opening phase was 33.8 kPa. The dynamic analysis indicated that the free edge regions of the leaflets were subjected to significant flexural deformation that may potentially lead to structural degeneration after millions of cycles of valve function. The regions subjected to time varying flexural deformation and high stresses of the present study also correspond to regions of tissue valve calcification and structural failure reported from explanted valves. In addition, the present simulation also demonstrated the importance of including the bending component together with the in-plane material behavior of the leaflets towards physiologically realistic deformation of the leaflets. Dynamic simulations with experimentally determined leaflet material specification can be potentially used to modify the valve towards an optimal design to minimize regions of stress concentration and structural failure.  相似文献   

6.
There is limited information about age-specific structural and functional properties of human heart valves, while this information is key to the development and evaluation of living valve replacements for pediatric and adolescent patients. Here, we present an extended data set of structure-function properties of cryopreserved human pulmonary and aortic heart valves, providing age-specific information for living valve replacements. Tissue composition, morphology, mechanical properties, and maturation of leaflets from 16 pairs of structurally unaffected aortic and pulmonary valves of human donors (fetal-53 years) were analyzed. Interestingly, no major differences were observed between the aortic and pulmonary valves. Valve annulus and leaflet dimensions increase throughout life. The typical three-layered leaflet structure is present before birth, but becomes more distinct with age. After birth, cell numbers decrease rapidly, while remaining cells obtain a quiescent phenotype and reside in the ventricularis and spongiosa. With age and maturation–but more pronounced in aortic valves–the matrix shows an increasing amount of collagen and collagen cross-links and a reduction in glycosaminoglycans. These matrix changes correlate with increasing leaflet stiffness with age. Our data provide a new and comprehensive overview of the changes of structure-function properties of fetal to adult human semilunar heart valves that can be used to evaluate and optimize future therapies, such as tissue engineering of heart valves. Changing hemodynamic conditions with age can explain initial changes in matrix composition and consequent mechanical properties, but cannot explain the ongoing changes in valve dimensions and matrix composition at older age.  相似文献   

7.
8.
目前临床使用的各种机械心脏瓣膜的主要问题是血栓栓塞和与抗凝治疗有关的出血,其缺陷在于瓣膜开启时,碟片和支架将瓣膜的整个血流通道分隔成三至四个较小的血流通道。在这种受阻隔的血流通宫,形成容易诱发血栓的高剪应力区、紊流和滞流区。我们研制的两种机械心脏瓣膜在瓣膜开启时,没有任何支架和碟片分隔瓣膜的血流通道,使血流与天然心脏瓣膜中的相类似,可减少对血液的危害,从而可减少换瓣病人对抗凝治疗的依赖程度。  相似文献   

9.
Living tissues show an adaptive response to mechanical loading by changing their internal structure and morphology. Understanding this response is essential for successful tissue engineering of load-bearing structures, such as the aortic valve. In this study, mechanically induced remodeling of the collagen architecture in the aortic valve was investigated. It was hypothesized that, in uniaxially loaded regions, the fibers aligned with the tensile principal stretch direction. For biaxial loading conditions, on the other hand, it was assumed that the collagen fibers aligned with directions situated between the principal stretch directions. This hypothesis has already been applied successfully to study collagen remodeling in arteries. The predicted fiber architecture represented a branching network and resembled the macroscopically visible collagen bundles in the native leaflet. In addition, the complex biaxial mechanical behavior of the native valve could be simulated qualitatively with the predicted fiber directions. The results of the present model might be used to gain further insight into the response of tissue engineered constructs during mechanical conditioning.  相似文献   

10.
All existing constitutive models for heart valve leaflet tissues either assume a uniform transmural stress distribution or utilize a membrane tension formulation. Both approaches ignore layer specific mechanical contributions and the implicit nonuniformity of the transmural stress distribution. To begin to address these limitations, we conducted novel studies to quantify the biaxial mechanical behavior of the two structurally distinct, load bearing aortic valve (AV) leaflet layers: the fibrosa and ventricularis. Strip biaxial tests, with extremely sensitive force sensing capabilities, were further utilized to determine the mechanical behavior of the separated ventricularis layer at very low stress levels. Results indicated that both layers exhibited very different nonlinear, highly anisotropic mechanical behaviors. While the leaflet tissue mechanical response was dominated by the fibrosa layer, the ventricularis contributed double the amount of the fibrosa to the total radial tension and experienced four times the stress level. The strip biaxial test results further indicated that the ventricularis exhibited substantial anisotropic mechanical properties at very low stress levels. This result suggested that for all strain levels, the ventricularis layer is dominated by circumferentially oriented collagen fibers, and the initial loading phase of this layer cannot be modeled as an isotropic material. Histological-based thickness measurements indicated that the fibrosa and ventricularis constitute 41% and 29% of the total layer thickness, respectively. Moreover, the extensive network of interlayer connections and identical strains under biaxial loading in the intact state suggests that these layers are tightly bonded. In addition to advancing our knowledge of the subtle but important mechanical properties of the AV leaflet, this study provided a comprehensive database required for the development of a true 3D stress constitutive model for the native AV leaflet.  相似文献   

11.
A study of mechanical heart valve behavior in the pulmonary position as a function of pulmonary vascular resistance is reported for the St. Jude Medical bileaflet (SJMB) valve and the MedicalCV Omnicarbon (OTD) tilting disk valve. Tests were conducted in a pulmonic mock circulatory system and impedance was varied in terms of system pulmonary vascular resistance (PVR). An impedance spectrum was found using instantaneous pulmonary artery pressure and flow rate curves. Both valves fully opened and closed at and above a nominal PVR of 3.0 mmHg/L/min. The SJMB valve was prone to leaflet bounce at closure, but otherwise completely closed, at settings above and below this nominal setting. At PVR values at and below 2.0 mmHg/L/min, the SJMB valve exhibited two types of leaflet aberrant behavior: single leaflet only closure while the other leaflet fluttered, and incomplete closure where both leaflets flutter but neither remain fully closed. The OTD valve fully opened and closed to a PVR value of 1.6 mmHg/L/min. At lower values, the valve did not close. Valves designed for the left heart can show aberrant behavior under normal conditions as pulmonary valves.  相似文献   

12.
SynerGraft® (SG) decellularized–cryopreserved cardiac valve allografts have been developed to provide a valve replacement option that has reduced antigenicity, retained structural integrity, and the ability to be stored long-term until needed for implantation. However, it is critical to ensure that both the SG processing and cryopreservation of these allografts do not detrimentally affect the extracellular matrix architecture within the tissue. This study evaluates the effects of SG decellularization and subsequent cryopreservation on the extracellular matrix integrity of allograft heart valves. Human aortic and pulmonary valves were trisected, with one-third of each either left fresh (no further processing after dissection), decellularized, or decellularized and cryopreserved. Two-photon laser scanning confocal microscopy was used to visualize collagen and elastin in leaflets and conduits. The optimized percent laser transmission (OPLT) required for full dynamic range imaging of each site was determined, and changes in OPLT were used to infer changes in collagen and elastin signal intensity. Collagen fiber crimp period and collagen and elastin fiber diameter were measured in leaflet tissue. Statistically significant differences in OPLT and the dimensional characteristics of collagen and elastin in study groups were determined through single factor ANOVA. The majority of donor-aggregated average OPLT observations showed no statistically significant differences among all groups, indicating no difference in collagen or elastin signal strength. Morphometric analysis of collagen and elastin fibers revealed no significant alterations in treated leaflet tissues relative to fresh tissues. Collagen and elastin structural integrity within allograft heart valves are maintained through SynerGraft® decellularization and subsequent cryopreservation.  相似文献   

13.
Efficient cell seeding and subsequent support from a substrate ensure optimal cell growth and neotissue development during tissue engineering, including heart valve tissue engineering. Fibrin gel as a cell carrier may provide high cell seeding efficiency and adhesion property, improved cellular interaction, and structural support to enhance cellular growth in trilayer polycaprolactone (PCL) substrates that mimic the structure of native heart valve leaflets. This cell carrier gel coupled with a trilayer PCL substrate may enable the production of native-like cell-cultured leaflet constructs suitable for heart valve tissue engineering. In this study, we seeded valvular interstitial cells onto trilayer PCL substrates with fibrin gel as a cell carrier and cultured them for 1 month in vitro to determine if this gel can improve cell proliferation and production of extracellular matrix within the trilayer cell-cultured constructs. We observed that the fibrin gel enhanced cellular proliferation, their vimentin expression, and collagen and glycosaminoglycan production, leading to improved structure and mechanical properties of the developing PCL cell-cultured constructs. Fibrin gel as a cell carrier significantly improved the orientations of the cells and their produced tissue materials within trilayer PCL substrates that mimic the structure of native heart valve leaflets and, thus, may be highly beneficial for developing functional tissue-engineered leaflet constructs.  相似文献   

14.
A nonlinear anisotropic model for porcine aortic heart valves   总被引:2,自引:0,他引:2  
Li J  Luo XY  Kuang ZB 《Journal of biomechanics》2001,34(10):1279-1289
The anisotropic property of porcine aortic valve leaflet has potentially significant effects on its mechanical behaviour and the failure mechanisms. However, due to its complex nature, testing and modelling the anisotropic porcine aortic valves remains a continuing challenge to date. This study has developed a nonlinear anisotropic finite element model for porcine heart valves. The model is based on the uniaxial experimental data of porcine aortic heart valve leaflet and the properties of nonlinear composite material. A finite element code is developed to solve this problem using the 8-node super-parameter nonlinear shells and the update Lagrangian method. The stress distribution and deformation of the porcine aortic valves with either uniform and non-uniform thicknesses in closed phase and loaded condition are calculated. The results showed significant changes in the stress distributions due to the anisotropic property of the leaflets. Compared with the isotropic valve at the same loading condition, it is found that the site of the peak stress of the anisotropic leaflet is different; the maximum longitudinal normal stress is increased, but the maximum transversal normal stress and in-plane shear stress are reduced. We conclude that it is very important to consider the anisotropic property of the porcine heart valves in order to understand the failure mechanism of such valves in vivo.  相似文献   

15.
Biaxial testing, histological measurements and theoretical continuum mechanics modeling were employed to investigate the structure and mechanical properties of the mitral valve leaflet-strut chordae transition zone (LCT). The results showed that geometry changes and collagen fiber angle distribution contribute to variations in mechanical properties in the LCT zone. A simple three-coefficient exponential constitutive law was able to simulate the variation in stress-stretch behavior in the LCT zone by spatially varying a single coefficient and incorporating collagen fiber angle and degree of alignment. This quantitative information can greatly improve the predictions from biomechanical valve models by incorporating regional variations of structure and properties in the mitral leaflet-chordae tendineae system. These data provide the foundation for a computational model for studying stress distributions before and following chordal rupture, which may indicate the underlying reasons for the development of valve insufficiency in patients.  相似文献   

16.
One of the major failure modes of bioprosthetic heart valves (BHVs) is noncalcific structural deterioration due to fatigue of the tissue leaflets; yet, the mechanisms of fatigue are not well understood. BHV durability is primarily assessed based on visual inspection of the leaflets following accelerated wear testing. In this study, we developed a computational framework to simulate BHV leaflet fatigue, which is both efficient and quantitative, making it an attractive alternative to traditional accelerated wear testing. We utilize a phenomenological soft tissue fatigue damage model developed previously to describe the stress softening and permanent set of the glutaraldehyde-treated bovine pericardium leaflets in BHVs subjected to cyclic loading. A parametric study was conducted to determine the effects of altered leaflet and stent elastic properties on the fatigue of the leaflets. The simulation results show that heterogeneity of the leaflet elastic properties, poor leaflet coaptation, and little stent-tip deflection may accelerate leaflet fatigue, which agrees with clinical findings. Therefore, the developed framework may be an invaluable tool for evaluating leaflet durability in new tissue valve designs, including traditional BHVs as well as new transcatheter valves.  相似文献   

17.
18.
Mechanical forces are known to affect the biomechanical properties of native and engineered cardiovascular tissue. In particular, shear stress that results from the relative motion of heart valve leaflets with respect to the blood flow is one important component of their mechanical environment in vivo. Although different types of bioreactors have been designed to subject cells to shear stress, devices to expose biological tissue are few. In an effort to address this issue, the aim of this study was to design an ex vivo tissue culture system to characterize the biological response of heart valve leaflets subjected to a well-defined steady or time-varying shear stress environment. The novel apparatus was designed based on a cone-and-plate viscometer. The device characteristics were defined to limit the secondary flow effects inherent to this particular geometry. The determination of the operating conditions producing the desired shear stress profile was streamlined using a computational fluid dynamic (CFD) model validated with laser Doppler velocimetry. The novel ex vivo tissue culture system was validated in terms of its capability to reproduce a desired cone rotation and to maintain sterile conditions. The CFD results demonstrated that a cone angle of 0.5 deg, a cone radius of 40 mm, and a gap of 0.2 mm between the cone apex and the plate could limit radial secondary flow effects. The novel cone-and-plate permits to expose nine tissue specimens to an identical shear stress waveform. The whole setup is capable of accommodating four cone-and-plate systems, thus concomitantly subjecting 36 tissue samples to desired shear stress condition. The innovative design enables the tissue specimens to be flush mounted in the plate in order to limit flow perturbations caused by the tissue thickness. The device is capable of producing shear stress rates of up to 650 dyn cm(-2) s(-1) (i.e., maximum shear stress rate experienced by the ventricular surface of an aortic valve leaflet) and was shown to maintain tissue under sterile conditions for 120 h. The novel ex vivo tissue culture system constitutes a valuable tool toward elucidating heart valve mechanobiology. Ultimately, this knowledge will permit the production of functional tissue engineered heart valves, and a better understanding of heart valve biology and disease progression.  相似文献   

19.
Abstract

Prestretch is observed in many soft biological tissues, directly influencing the mechanical behavior of the tissue in question. The development of this prestretch occurs through complex growth and remodeling phenomena, which yet remain to be elucidated. In the present study it was investigated whether local cell-mediated traction forces can explain the development of global anisotropic tissue prestretch in the mitral valve. Towards this end, a model predicting actin stress fiber-generated traction forces was implemented in a finite element framework of the mitral valve. The overall predicted magnitude of prestretch induced valvular contraction after release of in vivo boundary constraints was in good agreement with data reported on valvular retraction after excision from the heart. Next, by using a systematic variation of model parameters and structural properties, a more anisotropic prestretch development in the valve could be obtained, which was also similar to physiological values. In conclusion, this study shows that cell-generated traction forces could explain prestretch magnitude and anisotropy in the mitral valve.  相似文献   

20.
Supravalvular mitral stenosis is a rare condition characterized by an abnormal ridge, with one or two orifices, covering and obstructing the mitral valve. Preoperative diagnosis is difficult with transtoracic echo (TTE), angiography and magnetic resonance imaging (MRI). In this case, a 36-year-old male, was admitted to our Heart department: He experienced progressive dyspnea on effort and at rest. Diagnosis was made by transesophageal echocardiography which showed, on apical 4-chamber section, an anulare structure attached since a membrane to the atrial wall anterior mitral valve leaflet and just proximal to the posterior mitral leaflet. Pre-operative identification of the supravalvular mitral ring is the target for obtaining good surgical results. Cineangiography and MRI both failed in reaching this objective, whereas, transesophageal echocardiography is the best method to identify this congenital heart disease. Using TEE the identification is not only possible but also easier.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号