首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Quantification of gene expression provides valuable information regarding the response of cells or tissue to stimuli and often is accomplished by monitoring the level of messenger RNA (mRNA) being transcribed for a particular protein. Although numerous methods are commonly used to monitor gene expression, including Northern blotting, real-time polymerase chain reaction, and RNase protection assay, each method has its own drawbacks and limitations. Capillary electrophoresis with laser-induced fluorescence (CE-LIF) can reduce protocol time, eliminate the need for radioactivity, and provide superior sensitivity and dynamic range for quantification of RNA. In addition, CE-LIF can be used to directly determine the amount of an RNA species present, something that is difficult and not normally accomplished using current methods. Gene expression is detected using a fluorescently labeled riboprobe specific for a given RNA species. This direct approach was validated by analyzing levels of 28S RNA and also used to determine the amount of discoidin domain receptor 2 mRNA in cardiac tissue.  相似文献   

2.
Automation is essential for rapid genetic-based mutation analysis in clinical laboratory to screen a large number of DNA samples. We propose in this report an automatic process using Beckman Coulter P/ACE™ capillary electrophoresis (CE) with laser-induced fluorescence (LIF) system to detect a single-point mutation in the codon 12 of human K-ras gene. Polymerase chain reaction (PCR) using a fluorescently labeled reverse primer and a plain forward primer to specifically amplify a selected 50 bp DNA fragment in human K-ras gene. The amplified DNA is placed on the sample tray of the CE system with a pre-programmed step for single-strand conformation polymorphism (SSCP) analysis. Sample injection and denaturation processes are performed online along with separation and real-time data analysis. The concept of automation for rapid DNA mutation analysis using CE-LIF system for SSCP is presented.  相似文献   

3.
The tumor suppressor protein p53 is a key regulatory element in the cell and is regarded as the “guardian of the genome”. Much of the present knowledge of p53 function has come from studies of transgenic mice in which the p53 gene has undergone a targeted deletion. In order to provide additional insight into the impact on the cellular regulatory networks associated with the loss of this gene, microarray technology was utilized to assess gene expression in tissues from both the p53−/− and p53+/− mice. Six male mice from each genotype (p53+/+, p53+/−, and p53−/−) were humanely killed and the tissues processed for microarray analysis. The initial studies have been performed in the liver for which the Dunnett test revealed 1406 genes to be differentially expressed between p53+/+ and p53+/− or between p53+/+ and p53−/− at the level of p ≤ 0.05. Both genes with increased expression and decreased expression were identified in p53+/− and in p53−/− mice. Most notable in the gene list derived from the p53+/− mice was the significant reduction in p53 mRNA. In the p53−/− mice, not only was there reduced expression of the p53 genes on the array, but genes associated with DNA repair, apoptosis, and cell proliferation were differentially expressed, as expected. However, altered expression was noted for many genes in the Cdc42-GTPase pathways that influence cell proliferation. This may indicate that alternate pathways are brought into play in the unperturbed liver when loss or reduction in p53 levels occurs.  相似文献   

4.
Fundamental to understanding the role of cytosine (C) methylation in genomic DNA (gDNA) is the need for robust analysis methods to determine the location and degree of this modification. We report a novel method for methylation detection by denaturing capillary electrophoresis (CE) using standard fragment analysis conditions. Bisulfite treatment of gDNA will selectively deaminate C but not 5-methylcytosine (5mC). Amplicons generated from bisulfite-converted gDNA are analyzed immediately after PCR using a 6-carboxy fluorescein (6-FAM) dye-labeled primer. The amplicons from methylated and unmethylated gDNA separate based solely on base composition due to the presence of multiple C versus thymine (T) differences. By direct detection of PCR amplicons following PCR using primers that anneal independent of methylation status, the overall workflow from gDNA sample input to data analysis is relatively simple. Furthermore, the same PCR product is suitable for additional analyses such as direct sequencing, cloning and sequencing, single-base extension, and post-PCR incorporation of a modified dCTP, the latter of which allows resolution of amplicons with as little as a single C/T difference. We show the utility of this novel CE detection assay by analyzing the hypermethylated region of the fragile-X FMR1 locus.  相似文献   

5.
DNA amplification technology has been applied to clinical diagnosis of infectious disease, genetic disorder, and cancer. After in vitro amplification of a particular DNA region, the methods of analysis for these amplified samples play a pivotal role in clinical diagnosis. Conventional gel electrophoresis has been routinely used in the lab for checking DNA. The whole procedure is time consuming and requires more than 1 ng of DNA for detection. To achieve greater performance in DNA diagnosis, we demonstrated capillary electrophoresis with laser induced fluorescence detection for analysis of amplified DNA. The analysis of DNA could be completed within 3 min and the data is directly entered into the computer. Considering the automatic and rapid process, we believe that this method could be routinely utilized for the clinical diagnosis of amplified DNA products.  相似文献   

6.
The acidic oligosaccharides of human milk are predominantly sialyloligosaccharides. Pathogens that bind sialic acid-containing glycans on their host mucosal surfaces may be inhibited by human milk sialyloligosaccharides, but testing this hypothesis requires their reliable quantification in milk. Sialyloligosaccharides have been quantified by anion exchange high-performance liquid chromatography (HPLC), reverse- or normal-phase HPLC, and capillary electrophoresis (CE) of fluorescent derivatives; in milk, these oligosaccharides have been analyzed by high pH anion exchange chromatography with pulsed amperometric detection and, in our laboratory, by CE with detection at 205nm. The novel method described here uses a running buffer of aqueous 200mM NaH2PO4 (pH 7.05) containing 100mM sodium dodecyl sulfate (SDS) mixed with 45% (v/v) methanol to baseline resolve 5 oligosaccharides and separate all 12. This allows automated simultaneous quantification of the 12 major sialyloligosaccharides of human milk in a single 35-min run. This method revealed differences in sialyloligosaccharide concentrations between less and more mature milk from the same donors. Individual donors also varied in expression of sialyloligosaccharides in their milk. Thus, the facile quantification of sialyloligosaccharides by this method is suitable for measuring variation in expression of specific sialyloligosaccharides in milk and their relationship to decreased risk of specific diseases in infants.  相似文献   

7.
8.
Ferulic andp-coumaric acid can be separated from their corresponding aliphatic methyl esters by capillary zone electrophoresis, which allows the convenient determination of feruloyl andp-coumaroyl esterase activities using synthetic esters as substrates. A feruloyl-containing sugar ester from wheat bran was also efficiently separated and used as substrate for the enzyme assays.Penicillium expansum was shown to produce feruloyl/p-coumaroyl esterase activity when grown on wheat bran in solid-state culture.The authors are with the Food Microbiology Research Division, Department of Agriculture for Northern Ireland, Newforge Lane, Belfast BT9 5PX, UK; A.M. McKay is also affiliated with the Department of Food Science (Microbiology), The Queen's University of Belfast, Newforge Lane, Belfast BT9 5PX, UK.  相似文献   

9.
A novel capillary electrophoresis (CE) with chemiluminescence (CL) detection method for the determination of mitoxantrone (MTX) has been developed, which based on the CL reaction of potassium ferricyanide with luminol in sodium hydroxide medium sensitized by MTX. Under optimum analytical conditions, MTX is determined over the range of 7.0 × 10−8–1.0 × 10−6 M with a detection limit of 1.0 × 10−8 M. The relative standard deviation (RSD) was 3.7%, 2.6% and 3.0% for 7.0 × 10−8, 5.0 × 10−7 and 1.0 × 10−6 M MTX (n = 11), respectively. In laboratory-built CE–CL apparatus, the proposed method has been applied to determination of MTX in commercial drug and spiked in human urine and plasma with satisfactory results.  相似文献   

10.
The feasibility of employing classical electrophoresis theory to determine the net charge (valence) of proteins by capillary zone electrophoresis is illustrated in this paper. An outline of a procedure to facilitate the interpretation of mobility measurements is demonstrated by its application to a published mobility measurement for Staphylococcal nuclease at pH 8.9 that had been obtained by capillary zone electrophoresis. The significantly higher valence of +7.5 (cf. 5.6 from the same series of measurements) that has been reported on the basis of a "charge ladder" approach for charge determination signifies the likelihood that the latter generic approach may be prone to error arising from nonconformity of the experimental system with an inherent assumption that chemical modification or mutation of amino acid residues has no effect on the overall three-dimensional size and shape of the protein.  相似文献   

11.
Until recently, the approach to understanding the molecular basis of complex syndromes such as cancer, coronary artery disease, and diabetes was to study the behavior of individual genes. However, it is generally recognized that expression of a number of genes is coordinated both spatially and temporally and that this coordination changes during the development and progression of diseases. Newly developed functional genomic approaches, such as serial analysis of gene expression (SAGE) and DNA microarrays have enabled researchers to determine the expression pattern of thousands of genes simultaneously. One attractive feature of SAGE compared to microarrays is its ability to quantify gene expression without prior sequence information or information about genes that are thought to be expressed. SAGE has been successfully applied to the gene expression profiling of a number of human diseases. In this review, we will first discuss SAGE technique and contrast it to microarray. We will then highlight new biological insights that have emerged from its application to the study of human diseases.  相似文献   

12.
在所有研究过的人体肿瘤组织或细胞中,p53似乎是突变频率最高的一个基因,研究和检测p53基因及其编码产物的变化将具有重要的意义。我们将野生型p53基因编码区3’端703bp的cD-NA片段插入到大肠杆菌表达载体pBV220中,得到了一个重组体表达质粒pRR33,经热诱导表达,用SDS-PAGE和Western印迹法证实p53蛋白多肽在大肠杆菌中得到了表达,它不仅可用于抗p53蛋白抗体的制备,而且也可用于对p53蛋白羧基端多肽功能的研究。  相似文献   

13.
Single nucleotide incorporation assays have been used to probe the kinetic parameters of many DNA and RNA polymerases. Traditionally, oligonucleotide primers are 5'-(32)P labeled using T4 kinase and annealed to a complementary template with a 5' overhang. To quantify the reaction kinetics, the products of the primer extension reactions are usually separated using denaturing polyacrylamide gel electrophoresis and quantified using a phosphorimager or other method to measure radioactivity. We have developed a method using a 5' fluorescently labeled oligonucleotide to examine the kinetics of single nucleotide incorporation catalyzed by recombinant human mitochondrial polymerase gamma (Pol gamma) holoenzyme. Using laser-induced fluorescence detection in the P/ACE MDQ instrument, primers 5' labeled with fluorescent probes such as 6-carboxyfluorescein can be rapidly separated and quantified. However, we also show that only select probes can be used, presumably due to unfavorable interactions between Pol gamma and certain 5' labels.  相似文献   

14.
A high-performance capillary electrophoresis with electrochemical detection method has been developed for the determination of the pharmacologically active ingredients, acacetin, rutin, umbelliferone, kaempferol, apigenin, luteolin and quercetin, in Herba Saussureae Involucratae. Under optimum conditions, the seven analytes could be completely separated within 19 min in a 75 cm length capillary at a separation voltage of 16 kV in a 50 mM borax running buffer (pH 9.2). A 300 microm diameter carbon disk electrode, positioned opposite the outlet of the capillary in a wall-jet configuration at a potential of +950 mV (vs a saturated calomel electrode) was used as the working electrode. A good linear relationship was established between peak current and concentration of the analytes over two orders of magnitude with detection limits (signal-to-noise ratio = 3) ranging from 1.2 x 10(-7) to 4.1 x 10(-8) g/mL for all analytes. The proposed method has been successfully applied to the analyses of bio-active components of Herba Saussureae Involucratae samples after a relatively simple extraction procedure. The assay results show that the resultant electrochemical profiles are indicative of the content diversity of each electrochemically active ingredient in the various samples, and may also offer some evidence for phytotaxonomy.  相似文献   

15.
A method for coupling capillary zone electrophoresis (CZE) with rapid membrane chromatography purification (RMCP) was established for the analysis of vitellogenin (VTG) in male fish plasma induced with 17ss-estrodiol. CZE analyses of purified VTG were performed in a buffer containing 25 mM sodium borate (pH 8.4). A 50 microm i.d. fused-silica capillary was used for separation and the detection was carried out by UV-diode array at 214 nm. Inter- and intra-assay variabilities of the proposed method were less than 10.06 and 1.95%, respectively. The method has good linear relationship over the scope of 15-2250 microg/ml with a correlation coefficient of R2 = 0.9965 and a detection limit of 7.0 microg/ml. The established CZE method was also applied to directly separate and identify VTG from fish plasma. The results indicated this method could minimize interferences from plasma proteins, allowing the detection of at least 62.5 microg/ml of VTG proteins in total proteins. This is a rapid and easy method to determine the quantity and purity of VTG compared to Bradford method and SDS-PAGE.  相似文献   

16.
Two capillary electrophoretic methods were developed and evaluated for measurement of glycated hemoglobin A1c (HbA1c). First, a capillary electrophoresis analysis is performed with a sodium tetraborate buffer (pH 9.3) as background electrolyte in a neutrally coated capillary. HbA1c is separated from HbA0 due to specific interactions of borate anions with the cisdiol pattern in the saccharide moiety of glycohemoglobin. Second, a capillary isoelectric focusing method, which exploits a difference in pI values of HbA0 and HbA1c, is performed with Servalyt pH 6–8 or alternatively with Biolyte pH 6–8 carrier ampholytes spiked with a narrow pH cut of pH 7.2 prepared by preparative fractionation of Servalyt pH 4–9 carrier ampholytes. Both methods reflect recent developments in the methodology of capillary electrophoresis. They allow quantifying HbA1c in generic capillary electrophoresis analyzer with specificity that is consistent with previously reported electrophoretic assays in slab gels and capillaries.  相似文献   

17.
We report the study of several inhibitors on alanine aminotransferase (ALT) enzyme using sequential online capillary electrophoresis (CE) assay. Using metal ions (Na+ and Mg2+) as example inhibitors, we show that evolution of the ALT inhibition reaction can be achieved by automatically and simultaneously monitoring the substrate consumption and product formation as a function of reaction time. The inhibition mechanism and kinetic constants of ALT inhibition with succinic acid and two traditional Chinese medicines were derived from the sequential online CE assay. Our study could provide valuable information about the inhibition reactions of ALT enzyme.  相似文献   

18.
Traditional clinical assays for nonprotein nitrogen compounds, such as creatine and creatinine, have focused on the use of enzymes or chemical reactions that allow measurement of each analyte separately. Most of these assays are mainly directed to urine quantification, so that their applicability on plasma samples is frequently hard to perform. This work describes a simple free zone capillary electrophoresis method for the simultaneous measurement of creatinine and creatine in human plasma. The effect of analytical parameters such as concentration and pH of Tris-phosphate running buffer and cartridge temperature on resolution, migration times, peak areas, and efficiency was investigated. Good separation was achieved using a 60.2-cm x 75-microm uncoated silica capillary, 75 mmol/L Tris-phosphate buffer, pH 2.25, at 15 degrees C, in less than 8 min. We compared the present method to a validated capillary electrophoresis assay, by measuring plasma creatinine in 120 normal subjects. The obtained data were compared by the Passing-Bablok regression and the Bland-Altman test. Moreover the performance of the developed method was assessed by measuring creatine and creatinine in 16 volunteers prior to and after a moderate physical exercise.  相似文献   

19.
The three major curcuminoids, curcumin, demethoxycurcumin and bis-demethoxycurcumin, from Curcuma domestica Val. (Curcuma longa L.) and Curcuma xanthorrhiza Roxb. (Zingiberaceae) were fully separated and quantified in less than 5 min using a capillary zone electrophoresis method with standard fused-silica capillaries and photodiode array detection. An electrolyte solution of 20 mM phosphate, 50 mM sodium hydroxide and 14 mM beta-cyclodextrin was found to be appropriate. Quantification was performed with 3,4-dimethoxy-trans-cinnamic acid as internal standard, and the limit of detection was 0.01 mg/mL. Extraction, stabilisation during sample storage and quantification procedures were optimised and carried out with drugs and commercial curry powder from different provenances. The results were compared with the photometric method of the monograph Curcumae xanthorrhizae rhizoma of the European Pharmacopoeia.  相似文献   

20.
Tumor-specific alterations at the p53 gene locus were analyzed in 40 human brain tumor samples. Gliomas were more prevalent in young males and meningiomas in old females. Structural changes at the intron 1 region of the p53 gene were analyzed in these tumors by Southern blotting. Among the 40 tumors, 33 were informative and 21 of these (63.6%) informative cases showed loss of heterozygosity (LOH). This is the first report showing LOH at the intron 1 region of p53 gene in human brain tumors. The level of p53 mRNA, p53 protein and Ser 392 phosphorylated p53 protein were also analyzed in all tumor samples. Normal sized p53 mRNA and protein were present in all the tumor samples; however, their levels were 1.5- to 4-fold higher compared to the control suggesting deregulated p53 pathway in these tumors. No correlation was found between LOH status and the levels of p53 mRNA and protein. In all high-grade glioblastomas majority of the p53 protein existed as Ser 392 phosphorylated form as compared to low-grade gliomas. In addition, the percentage of Ser 392 phosphorylated form of p53 protein was lower in meningiomas and other brain tumor types irrespective of tumor grade. These results suggest involvement of Ser 392 phosphorylated form of p53 protein during the later stages of glioma development. These results also indicate that deregulation of p53 gene could occur at various steps in p53 pathway and suggest an overall deregulation of p53 gene in most brain tumor types.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号