首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Palladium nanoparticle-loaded carbon nanofibers (Pd/CNFs) were prepared by electrospinning and subsequent thermal treatment processes. Pd/CNFs modified carbon paste electrode (Pd/CNF-CPE) displayed excellent electrochemical catalytic activities towards dopamine (DA), uric acid (UA) and ascorbic acid (AA). The oxidation overpotentials of DA, UA and AA were decreased significantly compared with those obtained at the bare CPE. Differential pulse voltammetry was used for the simultaneous determination of DA, UA and AA in their ternary mixture. The peak separation between UA and DA, DA and AA was 148 mV and 244 mV, respectively. The calibration curves for DA, UA and AA were obtained in the range of 0.5-160 microM, 2-200 microM, and 0.05-4mM, respectively. The lowest detection limits (S/N=3) were 0.2 microM, 0.7 microM and 15 microM for DA, UA and AA, respectively. With good selectively and sensitivity, the present method was applied to the determination of DA in injectable medicine and UA in urine sample.  相似文献   

2.
A disposable and sensitive screen-printed electrode using an ink containing graphene was developed. This electrode combined the advantages of graphene and the disposable characteristic of electrode, which possessed wide potential window, low background current and fast electron transfer kinetics. Compared with the electrodes made from other inks, screen-printed graphene electrode (SPGNE) showed excellent electrocatalytic activity for the oxidation of ascorbic acid (AA), dopamine (DA), and uric acid (UA). Three well-defined sharp and fully resolved anodic peaks were found at the developed electrode. Differential pulse voltammetry was used to simultaneous determination of AA, DA, and UA in their ternary mixture. In the co-existence system of these three species, the linear response ranges for the determination of AA, DA, and UA were 4.0-4500 μM, 0.5-2000 μM, and 0.8-2500 μM, respectively. The detection limits (S/N=3) were found to be 0.95 μM, 0.12 μM, and 0.20 μM for the determination of AA, DA, and UA, respectively. Furthermore, the SPGNE displayed high reproducibility and stability for these species determination. The feasibility of the developed electrode for real sample analysis was investigated. Results showed that the SPGNE could be used as a sensitive and selective sensor for simultaneous determination of AA, DA, and UA in biological samples, which may provide a promising alternative in routine sensing applications.  相似文献   

3.
A recently constructed carbon composite electrode using room temperature ionic liquid as pasting binder was employed as a novel electrode for sensitive, simultaneous determination of dopamine (DA), ascorbic acid (AA), and uric acid (UA). The apparent reversibility and kinetics of the electrochemical reaction for DA, AA, and UA found were improved significantly compared to those obtained using a conventional carbon paste electrode. The results show that carbon ionic liquid electrode (CILE) reduces the overpotential of DA, AA, and UA oxidation, without showing any fouling effect due to the deposition of their oxidized products. In the case of DA, the oxidation and reduction peak potentials appear at 210 and 135mV (vs Ag/AgCl, KCl, 3.0M), respectively, and the CILE shows a significantly better reversibility for dopamine. The oxidation peak due to the oxidation of AA occurs at about 60mV. For UA, a sharp oxidation peak at 340mV and a small reduction peak at 250mV are obtained at CILE. Differential pulse voltammetry was used for the simultaneous determination of ternary mixtures of DA, AA, and UA. Relative standard deviation for DA, AA, and UA determinations were less than 3.0% and DA, AA, and UA can be determined in the ranges of 2.0x10(-6)-1.5x10(-3), 5.0x10(-5)-7.4x10(-3), and 2.0x10(-6)-2.2x10(-4)M, respectively. The method was applied to the determination of DA, AA, and UA in human blood serum and urine samples.  相似文献   

4.
A novel polycalconcarboxylic acid (CCA) modified glassy carbon electrode (GCE) was fabricated by electropolymerization and then successfully used to simultaneously determine ascorbic acid (AA), norepinephrine (NE) and uric acid (UA). The characterization of electrochemically synthesized Poly-CCA film was investigated by atomic force microscopy (AFM), electrochemical impedance spectroscopy (EIS) and voltammetric methods. It was found that the electrochemical behavior of the polymer-modified electrode depended on film thickness, i.e., the electropylmyerization time. Based on the electrochemical data, the charge transfer coefficient (alpha) and the surface coverage (Gamma) were calculated. This poly-CCA modified GCE could reduce the overpotential of ascorbic acid (AA), norepinephrine (NE) and uric acid (UA) oxidation in phosphate buffer solution (pH 6.0), while it increases the peak current significantly. The current peak separations of AA/NE, NE/UA and AA/UA on this modified electrode are 91mV, 256mV and 390mV in CV at 100mVs(-1), respectively. Therefore, the voltammetric responses of these three compounds can be well resolved on the polymer-modified electrode, and simultaneously determination of these three compounds can be achieved. In addition, this modified electrode can be successfully applied to determine AA and NE in injection and UA in urine samples without interferences.  相似文献   

5.
This article describes the selective determination of inosine (INO) in the presence of important physiological interferents, uric acid (UA) and hypoxanthine (HXN), by differential pulse voltammetry at physiological pH (7.2) using the electropolymerized film of 3-amino-5-mercapto-1,2,4-triazole (p-AMTa) modified glassy carbon (GC) electrode. The electropolymerization of AMTa was carried out by the potentiodynamic method in 0.1M H(2)SO(4). An atomic force microscopy image shows that the p-AMTa film contains a spherical-like structure. Bare GC electrode fails to resolve the voltammetric signal of INO in the presence of UA and HXN due to the surface fouling caused by the oxidized products of UA and HXN. However, p-AMTa film modified GC electrode (p-AMTa electrode) not only separates the voltammetric signals of UA, HXN, and INO, with potential differences of 730 mV between UA and HXN and 310 mV between HXN and INO, but also shows enhanced oxidation current for them. The selective determination of INO in the presence of UA and HXN at physiological pH was achieved for the first time. Using the amperometric method, we achieved the lowest detection of 50 nM for INO. The practical application of the current modified electrode was demonstrated by determining the concentration of INO in human blood serum and urine samples.  相似文献   

6.
A stable electroactive thin film of poly(caffeic acid) has been deposited on the surface of a glassy carbon electrode by potentiostatic technique in an aqueous solution containing caffeic acid. Poly(caffeic acid) was used as a modified electrode for the detection of ascorbic acid (AA), epinephrine (EP), uric acid (UA) and their mixture by cyclic voltammetry. This modified electrode exhibits potent and persistent electron-mediating behavior followed by well-separated oxidation peaks towards AA, EP and UA with activation overpotential. For the ternary mixture containing AA, EP and UA, the three compounds can well separate from each other at the scan rate of 20 mVs(-1) with a potential difference of 156, 132 and 288 mV between AA and EP, EP and UA and AA and UA, respectively, which was large enough to determine AA, EP and UA individually and simultaneously. The catalytic peak current obtained, was linearly dependent on the AA, EP and UA concentrations in the range of 2.0 x 10(-5) to 1.0 x 10(-3) mol l(-1), 2.0 x 10(-6) to 8.0 x 10(-5) mol l(-1) and 5.0 x 10(-6) to 3.0 x 10(-4) mol l(-1), and the detection limits for AA, EP and UA were 7.0 x 10(-6), 2.0 x 10(-7) and 6.0 x 10(-7) mol l(-1), respectively. The modified electrode shows good sensitivity, selectivity and stability, and has been applied to the determination of EP in practical injection samples and that of EP, UA and AA simultaneously with satisfactory results.  相似文献   

7.
A novel biosensor has been constructed by the electrodeposition of Au-nanoclusters (nano-Au) on poly(3-amino-5-mercapto-1,2,4-triazole) (p-TA) film modified glassy carbon electrode (GCE) and employed for the simultaneous determination of dopamine (DA), ascorbic acid (AA), uric acid (UA) and nitrite (NO2). NH2 and SH groups exposed to the p-TA layer are helpful for the electrodeposition of nano-Au. The combination of nano-Au and p-TA endow the biosensor with large surface area, good biological compatibility, electricity and stability, high selectivity and sensitivity and flexible and controllable electrodeposition process. In the fourfold co-existence system, the linear calibration plots for AA, DA, UA and NO2 were obtained over the range of 2.1–50.1 μM, 0.6–340.0 μM, 1.6–110.0 μM and 15.9–277.0 μM with detection limits of 1.1 × 10−6 M, 5.0 × 10−8 M, 8.0 × 10−8 M and 8.9 × 10−7 M, respectively. In addition, the modified biosensor was applied to the determination of AA, DA, UA and NO2 in urine and serum samples by using standard adding method with satisfactory results.  相似文献   

8.
The use of poly(acrylic acid) (PAA)-multiwalled carbon-nanotubes (MWNTs) composite-coated glassy-carbon disk electrode (GCE) (PAA-MWNTs/GCE) for the simultaneous determination of physiological level dopamine (DA) and uric acid (UA) in the presence of an excess of ascorbic acid (AA) in a pH 7.4 phosphate-buffered solution was proposed. PAA-MWNTs composite was prepared by mixing of MWNTs powder into 1 mg/ml PAA aqueous solution under sonication. GCE surface was modified with PAA-MWNTs film by casting. AA demonstrates no voltammetric peak at PAA-MWNTs/GCE. The PAA-MWNTs composite is of a high surface area and of affinity for DA and UA adsorption. DA exhibits greatly improved electron-transfer rate and is electro-catalyzed at PAA-MWNTs/GCE. Moreover, the electro-catalytic oxidation of UA at PAA-MWNTs/GCE is observed, which makes it possible to detect lower level UA. Therefore, the enhanced electrocatalytic currents for DA and UA were observed. The anodic peak currents at approximately 0.18 V and 0.35 V increase with the increasing concentrations of DA and UA, respectively, which correspond to the voltammetric peaks of DA and UA, respectively. The linear ranges are 40 nM to 3 microM DA and 0.3 microM to 10 microM UA in the presence of 0.3 mM AA. The lowest detection limits (S/N=3) were 20 nM DA and 110 nM UA.  相似文献   

9.
Hou S  Zheng N  Feng H  Li X  Yuan Z 《Analytical biochemistry》2008,381(2):179-184
A polymerized film of 3,5-dihydroxy benzoic acid (DBA) was prepared on the surface of a glassy carbon electrode (GCE) in neutral solution by cyclic voltammetry (CV). The poly(DBA) film-coated GCE exhibited excellent electrocatalytic activity toward the oxidation of dopamine (DA). A linear range of 1.0 × 10−7 to 1.0 × 10−4 M and a detection limit of 6.0 × 10−8 M were observed in pH 7.4 phosphate buffer solutions. Moreover, the interference of ascorbic acid (AA) was effectively eliminated. This work provides a simple and easy approach to selective detection of DA in the presence of AA.  相似文献   

10.
A chemometric-assisted kinetic spectrophotometric method has been developed for simultaneous determination of ascorbic acid (AA), uric acid (UA), and dopamine (DA). This method relies on the difference in the kinetic rates of the reactions of analytes with a common oxidizing agent, tris(1,10-phenanthroline) and iron(III) complex (ferritin, [Fe(phen)3]3+) at pH 4.4. The changes in absorbance were monitored spectrophotometrically. The data obtained from the experiments were processed by chemometric methods of artificial neural network (ANN) and partial least squares (PLS). Acceptable techniques of prediction set, randomization t test, cross-validation, and Y randomization were applied for the selection of the best chemometric method. The results showed that feedforward artificial neural network (FFANN) is more efficient than the other chemometric methods. The parameters affecting the experimental conditions were optimized, and it was found that under optimal conditions Beer’s law is followed in the concentration ranges of 4.3–74.1, 4.3–78.3, and 2.0–33.0 μM for AA, UA, and DA, respectively. The proposed method was successfully applied to the determination of analytes in serum and urine samples.  相似文献   

11.
Nitrogen doped graphene (NG) was prepared by thermally annealing graphite oxide and melamine mixture. After characterization by atomic force microscopy and X-ray photoelectron spectroscopy etc., the electrochemical sensor based on NG was constructed to simultaneously determine small biomolecules such as ascorbic acid (AA), dopamine (DA) and uric acid (UA). Due to its unique structure and properties originating from nitrogen doping, NG shows highly electrocatalytic activity towards the oxidation of AA, DA and UA. The electrochemical sensor shows a wide linear response for AA, DA and UA in the concentration range of 5.0×10(-6) to 1.3×10(-3)M, 5.0×10(-7) to 1.7×10(-4)M and 1.0×10(-7) to 2.0×10(-5)M with detection limit of 2.2×10(-6)M, 2.5×10(-7)M and 4.5×10(-8)M at S/N=3, respectively. These results demonstrate that NG is a promising candidate of advanced electrode material in electrochemical sensing and other electrocatalytic applications.  相似文献   

12.
Multilayer films of shortened multi-walled carbon nanotubes (MWNTs) are homogeneously and stably assembled on glassy carbon (GC) electrodes using layer-by-layer (LBL) method based on electrostatic interaction of positively charged poly(diallyldimethylammonium chloride) (PDDA) and negatively charged shortened MWNTs. The assembled MWNT multilayer films were studied with respect to the electrocatalytic activity toward ascorbic acid (AA) and dopamine (DA) and were further applied for selective determination of DA in the presence of AA. Scanning electron microscopy (SEM) used for characterization of MWNT films indicates that the assembled MWNTs are almost in a form of small bundles or single nanotubes on the electrodes. Cyclic voltammetric results with assembled MWNT electrode indicate that the strategy based on the LBL method for assembling the MWNT multilayer films on substrate well retains the electrochemical catalytic activity of the MWNTs toward AA and DA, offering some advantages particularly attractive for analytical applications, such as the form of MWNTs assembled on the substrate, i.e., small bundles or single tubes, homogeneity and stability of the as-assembled MWNT films. These features make the assembled MWNTs relatively potential for selective and sensitive determination of DA in the presence of AA.  相似文献   

13.
Hollow nitrogen-doped carbon microspheres (HNCMS) as a novel carbon material have been prepared and the catalytic activities of HNCMS-modified glassy carbon (GC) electrode towards the electro-oxidation of uric acid (UA), ascorbic acid (AA) and dopamine (DA) have also been investigated. Comparing with the bare GC and carbon nanotubes (CNTs) modified GC (CNTs/GC) electrodes, the HNCMS modified GC (HNCMS/GC) electrode has higher catalytic activities towards the oxidation of UA, AA and DA. Moreover, the peak separations between AA and DA, and DA and UA at the HNCMS/GC electrode are up to 212 and 136 mV, respectively, which are superior to those at the CNTs/GC electrode (168 and 114 mV). Thus the simultaneous determination of UA, AA and DA was carried out successfully. In the co-existence system of UA, AA and DA, the linear response range for UA, AA and DA are 5-30 μM, 100-1000 μM and 3-75 μM, respectively and the detection limits (S/N = 3) are 0.04 μM, 0.91 μM and 0.02 μM, respectively. Meanwhile, the HNCMS/GC electrode can be applied to measure uric acid in human urine, and may be useful for measuring abnormally high concentration of AA or DA. The attractive features of HNCMS provide potential applications in the simultaneous determination of UA, AA and DA.  相似文献   

14.
Individual and simultaneous determination of 50 nM uric acid (UA) and ascorbic acid (AA) using enlarged, citrate-stabilized gold nanoparticles (AuNPs) self-assembled to 2,5-dimercapto-1,3,4-thiadiazole (DMT) monolayer modified Au (Au/DMT) electrode by an amperometric method is described for the first time. Self-assembly of AuNPs on the electrode surface was confirmed by atomic force microscopy (AFM), attenuated total reflectance FT-IR and diffuse reflectance spectral measurements. The electron transfer reaction (ETR) of [Fe(CN)6]3−/4− was blocked at Au/DMT electrode, whereas it was restored with a peak separation of 200 mV after the attachment of AuNPs on the Au/DMT (Au/DMT/AuNPs) electrode, which was confirmed from the ETR of the [Fe(CN)6]3−/4− redox couple. When the self-assembled AuNPs were enlarged by hydroxylamine seeding, the ETR of [Fe(CN)6]3−/4− was improved significantly with a peak separation of 100 mV. Tapping mode AFM showed that the average size of the enlarged-AuNPs (E-AuNPs) was 50-70 nm. The E-AuNPs modified electrode catalyzes the oxidation of AA and UA, separates their voltammetric signals by 200 mV, and has excellent sensitivity towards AA and UA with a detection limit of 50 nM. The practical application of the modified electrode was demonstrated by measuring the concentration of UA in blood serum and urine.  相似文献   

15.
The level of uric acid (UA) has a high relationship with gout, hyperuricemia and Lesch-Nyan syndrome. The determination of UA is an important indicator for clinics and diagnoses of kidney failure. An amperometric UA biosensor based on an Ir-modified carbon (Ir-C) working electrode with immobilizing uricase (EC 1.7.3.3) was developed by thick film screen printing technique. This is the first time to report the utilization of an uricase/Ir-C electrode for the determination of UA by using chronoamperometric (CA) method. The high selectivity of UA biosensor was achieved due to the reduction of H(2)O(2) oxidation potential based on Ir-C electrode. Using uricase/Ir-C as the sensing electrode, the interference from the electroactive biological species, such as ascorbic acid (AA) and UA (might be directly oxidized on the sensing electrode) was slight at the sensing potential of 0.25 V (versus Ag/AgCl). UA was detected amperometrically based on uricase/Ir-C electrode with a sensitivity of 16.60 microAmM(-1) over the concentration range of 0.1-0.8 mMUA, which was within the normal range in blood. The detection limit of UA biosensor was 0.01 mM (S/N=6.18) in pH 7 phosphate buffer solution (PBS) at 37 degrees C. The effects of pH, temperature, and enzymatic loading on the sensing characteristics of the UA biosensor were also investigated in this study.  相似文献   

16.
A composite film of polyaniline (PAN) nano-networks/p-aminobenzene sulfonic acid (ABSA) modified glassy carbon electrode (GCE) has been fabricated via an electrochemical oxidation procedure and applied to the electro-catalytic oxidation of uric acid (UA) and ascorbic acid (AA). The ABSA monolayer at GCE surface has been characterized by X-ray photo-electron spectroscopy (XPS) and electrochemical techniques. Atomic force microscopy (AFM), field emission scanning electron microscope (SEM), electrochemical impedance spectroscopy (EIS), UV-visible absorption spectra (UV-vis) and cyclic voltammetry (CV) have been used to investigate the PAN-ABSA composite film, which demonstrates the formation of the composite film and the maintenance of the electroactivity of PAN in neutral and even in alkaline media. Due to its different catalytic effects towards the electro-oxidation of UA and AA, the modified GCE can resolve the overlapped voltammetric response of UA and AA into two well-defined voltammetric peaks with both CV and differential pulse voltammetry (DPV), which can be used for the selective and simultaneous determination of these species in a mixture. The catalytic peak currents are linearly dependent on the concentrations of UA and AA in the range of 50-250 and 35-175mumoll(-1) with correlation coefficients of 0.997 and 0.998, respectively. The detection limits for UA and AA are 12 and 7.5mumoll(-1), respectively. Besides the good stability and reproducibility of PAN-ABSA/GCE due to the covalent attachment of ABSA at GCE surface, the modified electrode also exhibits good sensitivity and selectivity.  相似文献   

17.
Wu S  Wang T  Gao Z  Xu H  Zhou B  Wang C 《Biosensors & bioelectronics》2008,23(12):1776-1780
A beta-cyclodextrin (CD) modified copolymer membrane of sulfanilic acid (p-ASA) and N-acetylaniline (SPNAANI) on glassy carbon electrode (GCE) was prepared and used to determine uric acid (UA) in the presence of a large excess of ascorbic acid (AA) by differential pulse voltammetry (DPV). The properties of the copolymer were characterized by X-ray photoelectron spectra (XPS) and Raman spectroscopy. The oxidation peaks of AA and UA were well separated at the composite membrane modified electrode in phosphate buffer solution (PBS, pH 7.4). A linear relationship between the peak current and the concentration of UA was obtained in the range from 1.0 x 10(-5) to 3.5 x 10(-4)mol L(-1), and the detection limit was 2.7 x 10(-6)mol L(-1) at a signal-to-noise ratio of 3. Two hundred and fifty-fold excess of AA did not interfere with the determination of UA. The application of the prepared electrode was demonstrated by measuring UA in human serum samples without any pretreatment, and the results were comparatively in agreement with the spectrometric clinical assay method.  相似文献   

18.
A rapid and simple method for the simultaneous analysis of uric and ascorbic acid in extracts of animal tissue is described. The method uses reversed-phase ion-pair chromatography with ultraviolet detection. The technique allows efficient separation of both acids while showing high selectivity, recovery, reproducibility, and sample stability. Calculated levels of both substances in mouse liver tissue were 1.00 +/- 0.05 mumol ascorbic acid/g and 130 +/- 5 nmol uric acid/g.  相似文献   

19.
The electrochemical modification of clenbuterol (CLB) was studied at paraffin-impregnated graphite electrode (WGE) in two potential ranges of 0.0-1.6V and -1.2 to 1.2V. Various methods including X-ray photoelectron spectroscopy (XPS), UV-spectroelectrochemistry, infrared (IR) spectra and electrochemical techniques have been used to characterizing the modification. Clenbuterol can be modified at the electrode surface by carbon-nitrogen linkage or carbon-carbon linkage in 0.0-1.6V or -1.2 to 1.2V, respectively. The electrochemical behaviors of dopamine (DA), norepinephrine (NE), adrenalin (EP), ascorbic acid (AA) and uric acid (UA) were studied at clenbuterol-modified paraffin-impregnated graphite electrode (CLB/WGE), and it was found that all these compounds could be detected successfully.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号