Goal: This paper reviews recent studies evaluating human subjects for physiologic or neuro-cognitive function adverse effects resulting from exposure to static magnetic fields of magnetic resonance imaging systems.

Materials and Methods: The results of three studies are summarized. Two studies evaluated exposure to a maximum of 8 Tesla (T). The first series studied 25 normal human subjects’ sequential vital signs (heart rate, blood pressure, blood oxygenation, core temperature, ECG, respiratory rate) measured at different magnetic field strengths to a maximum of 8 T. A second series of 25 subjects were studied at 0.05 and 8 T (out and in the bore of the magnet), performing 12 different standardized neuro-psychological tests and auditory–motor reaction times. The subjects’ comments were recorded immediately following the study and after a three-month interval. The third study contained 17 subjects, placed near the bore of a 1.5 T magnet, and it used six different cognitive, cognitive–motor, or sensory tests.

Results: There were no clinically significant changes in the subjects’ physiologic measurements at 8 T. There was a slight increase in the systolic blood pressure with increasing magnetic field strength. There did not appear to be any adverse effect on the cognitive performance of the subjects at 8 T. A few subjects commented at the time of initial exposure on dizziness, metallic taste in the mouth, or discomfort related to the measurement instruments or the head coil. There were no adverse comments at 3 months. The 1.5 T study had two of the four neuro-behavioral domains exhibiting adverse effects (sensory and cognitive–motor).

Conclusions: These studies did not demonstrate any clinically relevant adverse effects on neuro-cognitive testing or vital sign changes. One short-term memory, one sensory, and one cognitive–motor test demonstrated adverse effects, but the significance is not clear.  相似文献   


2.
Magnetic resonance imaging (MRI) is an easily automated, reliable technique to investigate axial mixing within rotating drums. Moist bran can be clearly differentiated from dry bran using MRI allowing a non-segregating tracer for axial mixing. For a 20-cm diameter drum, the axial dispersion coefficient in the particle bed was 0.51 cm s–2. Axial dispersion is scale-dependent.  相似文献   

3.
We report a screening procedure to predict ligand coordination to EuII and EuIII using magnetic resonance imaging in which bright images indicate complexation and dark images indicate no complexation. Here, paramagnetic GdIII is used as a surrogate for EuIII in the screening procedure to enable detection with magnetic resonance imaging. The screening procedure was tested using a set of eight ligands with known coordination to EuII and EuIII, and results were found to be consistent with expected binding. Validation of the screening procedure with known coordination chemistry enables use with new ligands in the future.  相似文献   

4.
Muscle cross-section measurement by magnetic resonance imaging   总被引:1,自引:0,他引:1  
Muscle cross-section areas were measured by magnetic resonance imaging (MRI) in the thigh of a human cadaver, the results being compared with those obtained by photography of corresponding anatomic macroslices. A close correlation was found between MRI and photographic evaluation, differences between the methods ranging from nil to 9.5%, depending on the scan position and the muscle groups. In vivo MRI measurements were performed on 12 female and 16 male students, the objectivity, the test-retest reliability and the variability of the MRI measurements being studied by fixing the scan position either manually or by coronary scan. The latter method appeared to be more objective and reliable. The coefficients of variation for muscle cross-section areas measured by MRI were in the range of those for the planimetry of given cross-section areas. Allowing for differentiation between several small muscle bundles in a given area, MRI proved to be a suitable method to quantify muscle cross-sections for intra- and interindividual analysis of muscle size.  相似文献   

5.
Cellulose fibers in water form networks that give rise to an apparent yield stress, especially at high solids contents. Measuring the yield stress and correlating it with fiber concentration is important for the biomass and pulp industries. Understanding how the yield stress behaves at high solids concentrations is critical to optimize enzymatic hydrolysis of biomass in the production of biofuels. Rheological studies on pretreated corn stover and various pulp fibers have shown that yield stress values correlate with fiber mass concentration through a power‐law relationship. We use magnetic resonance imaging (MRI) as an in‐line rheometer to measure velocity profiles during pipe flow. If coupled with pressure drop measurements, these allow yield stress values to be determined. We compare our results with literature values and discuss the accuracy and precision of the rheo‐MRI measurement, along with the effects of fiber characteristics on the power‐law coefficients. Biotechnol. Bioeng. 2011;108: 2312–2319. © 2011 Wiley Periodicals, Inc.  相似文献   

6.
Fifty normal noninfarct patients and 12 cases with infarcts of the cerebrum were examined with routine magnetic resonance imaging and echo-planar diffusion-weighted imaging. The diffusion-weighted three-dimensional images were reconstructed with volume-rendering processing on workstation. Precentral gyrus, post-central gyrus, superior parietal lobule, superior frontal gyrus, precentral sulcus, central sulcus, postcentral sulcus, intraparietal sulcus and superior frontal sulcus were best shown of all structures with an arbitrary score of 2.61–2.77. Supramarginal gyrus, middle frontal gyrus, inferior frontal gyrus and lateral sulcus were clearly shown in the majority of the cerebra with average scores of 2.0–2.49; angular gyrus, inferior frontal sulcus and superior temporal gyrus were not demonstrated satisfactorily and their average scores were 1.67–1.89. Middle temporal gyrus, inferior temporal gyrus, superior temporal sulcus and inferior temporal sulcus were difficult to identify, and thus had average scores of 0.87–1.26. Brain surface structures were better displayed in the older group of individuals than in the younger group. The structures in the 12 cases with acute or chronic cerebrum infarcts were also satisfactorily demonstrated with this new technique.  相似文献   

7.
Cardiac magnetic resonance imaging (CMR) is a new robust versatile non-invasive imaging technique that can detect global and regional myocardial dysfunction, presence of myocardial ischaemia and myocardial scar tissue in one imaging session without radiation, with superb spatial and temporal resolution, inherited three-dimensional data collection and with relatively safe contrast material. The reproducibility of CMR is high which makes it possible to use this technique for serial assessment to evaluate the effect of revascularisation therapy in patients with ischaemic heart disease.  相似文献   

8.
Additional tools to analyze follicle development would be highly advantageous because current methods require sacrifice of animals at specific times and time-consuming sectioning of tissues for histologic analysis. Magnetic resonance imaging (MRI) may provide a less involved, faster and more cost-effective method to analyze follicles in whole ovaries. Fixed ovaries were collected at different stages of the estrus cycle and after stimulation with gonadotrophins (24 and 48 h post pregnant mares serum (PMSG), and 10 and 24 h post human chorionic gonadotrophin (hCG)) with or without administration of the contrast agent gadodiamide. The MR images were generated using a vertical-bore, 11.7 Tesla MR system. Analysis of the MR images revealed large antral follicles in fixed ovaries with the oocyte and cumulus mass identifiable within preovulatory follicles. The use of gadodiamide had no impact on the quality of MR images obtained. The fixed ovaries were paraffin embedded, sectioned, and hematoxylin stained. Follicles were counted using the MR images and the histology sections. Preovulatory follicle numbers determined using MR images were comparable to those using histology; however counts of smaller follicles were inconsistent. MRI of gonadotrophin-stimulated ovaries in situ did not reveal discernable ovarian structures. Therefore, MRI is a useful tool for studying whole fixed ovaries leaving the ovary intact for additional analyses or for selection of samples based on morphology. The MRI is also useful for identifying preovulatory follicles, although analysis of smaller follicles is not possible, and thus the potential exists for cyst analysis in mouse models of polycystic ovarian syndrome (PCOS).  相似文献   

9.
Novel magnetic resonance imaging sequences have and still continue to play an increasing role in neuroimaging and neuroscience. Among these techniques, diffusion-weighted imaging (DWI) has revolutionized the diagnosis and management of diseases such as stroke, neoplastic disease and inflammation. However, the effects of aging on diffusion are yet to be determined. To establish reference values for future experimental mouse studies we tested the hypothesis that absolute apparent diffusion coefficients (ADC) of the normal brain change with age. A total of 41 healthy mice were examined by T2-weighted imaging and DWI. For each animal ADC frequency histograms (i) of the whole brain were calculated on a voxel-by-voxel basis and region-of-interest (ROI) measurements (ii) performed and related to the animals' age. The mean entire brain ADC of mice <3 months was 0.715(+/-0.016) x 10(-3) mm2/s, no significant difference to mice aged 4 to 5 months (0.736(+/-0.040) x 10(-3) mm2/s) or animals older than 9 months 0.736(+/-0.020) x 10(-3) mm2/s. Mean whole brain ADCs showed a trend towards lower values with aging but both methods (i + ii) did not reveal a significant correlation with age. ROI measurements in predefined areas: 0.723(+/-0.057) x 10(-3) mm2/s in the parietal lobe, 0.659(+/-0.037) x 10(-3) mm2/s in the striatum and 0.679(+/-0.056) x 10(-3) mm2/s in the temporal lobe. With advancing age, we observed minimal diffusion changes in the whole mouse brain as well as in three ROIs by determination of ADCs. According to our data ADCs remain nearly constant during the aging process of the brain with a small but statistically non-significant trend towards a decreased diffusion in older animals.  相似文献   

10.
11.
PurposeIn previous studies, methylthymol-blue and benzoic acid have been introduced as a diffuser limiter and sensitivity enhancer in the gel dosimeter composition, respectively. This work focused on analyzing a formulation of the Fricke gel dosimeter consisting of methylthymol-blue and benzoic acid through magnetic resonance imaging.MethodsThe gel dosimeter samples were irradiated using 6, 10, and 15 MV photons with different levels of doses and read using a 1.5 T scanner in order to evaluate the dose–response sensitivity and to study the effect of benzoic acid concentration, diffusion coefficient and temperature and to determine the temporal stability of the gel dosimeter.ResultsInspection of radiological properties revealed that this gel dosimeter can be considered as a tissue equivalent medium. Within the dose range 0 to 1000 cGy, the R1 sensitivity and R2 sensitivity of the gel dosimeter equaled 0.058 ± 0.003 and 0.092 ± 0.004 s−1Gy−1, respectively. The diffusion coefficient was less than 0.85 ± 0.02mm2h−1 for doses higher than 200 cGy. In addition, by changing the temperature from 15C to 25, the R1 sensitivity and R2 sensitivity decreased about 5 and 11%, respectively. Further, no significant energy and dose rate dependence were observed over photon energies of 6, 10, and 15 MV and over the range 65 to 525 cGy min−1.ConclusionsBased on our observation, the ferrous benzoic acid methylthymol-blue gel dosimeter can be suggested to measure the dose distribution. Further analysis is required to clarify its performance in clinical situations.  相似文献   

12.
目的大鼠是常用的制备心脏病模型的实验动物,而磁共振成像(MRI)技术已经成为评价心脏病模型病理进程和药效的重要技术手段,但是目前国内外没有正常大鼠心脏的磁共振成像技术参数,影响了这一技术的应用。本文利用磁共振成像技术,采集和定量分析Wistar、Sprague-Dawley和Lewis三种常用大鼠的左、右心室功能参数,为心脏病模型制备和分析提供参考数据。方法利用7.0T高场强MRI心脏电影(CINE)序列,分析这三种常用大鼠活体心脏组织的左、右心室心功能参数。结果获得三种大鼠左、右心室的8—9周龄功能参数,包括:左、右心室的舒张末容积(EDV)、收缩末容积(ESV)、射血分数(EF);左心室乳头肌层面舒张末期内径(EDD)、收缩末期内径(ESD)、短轴缩短率(Fs)、舒张末前后室壁厚度(EDAWT,EDPWT)、收缩末前后室壁厚度(ESAWT,ESPWT)、前室壁增厚率(AWT)和后室壁增厚率(PwT);右心室乳头肌层面舒张末室壁厚度(EDWT)、收缩末室壁厚度(ESWT)和室壁增厚率(WT)等十八项心脏主要功能和结构的正常值。结论本研究获得的三种大鼠十八项心脏主要功能和结构的正常值,可作为心脏病模型制备成模判定和病理进程、药物评价的参考数据。  相似文献   

13.
Acute nodularin-induced hepatotoxicity was assessed in vivo, in rats using magnetic resonance (MR) techniques, including MR imaging (MRI), MR spectroscopy (MRS), and electron paramagnetic resonance (EPR) oximetry. Nodularin is a cyclic hepatotoxin isolated from the cyanobacterium Nodularia spumigena. Three hours following the intraperitoneal (i.p.) administration of nodularin (LD50), a region of 'damage', characterized by an increase in signal intensity, was observed proximal to the porta hepatis (PH) region in T2-weighted MR images of rat liver. Image analysis of these regions of apparent 'damage' indicated a statistically significant increase in signal intensity around the PH region following nodularin administration, in comparison with controls and regions peripheral to the PH region. An increase in signal intensity was also observed proximal to the PH region in water chemical shift selective images (CSSI) of nodularin-treated rat livers, indicating that the increased signal observed by MRI is an oedematous response to the toxin. Microscopic assessment (histology and electron microscopy) and serum liver enzyme function tests (aminotransferase (ALT) and aspartate ALT (AST)) confirmed the nodularin-induced tissue injury observed by MRI. In vivo and in vitro MRS was used to detect alterations in metabolites, such as lipids, Glu+Gln, and choline, during the hepatotoxic response (2-3 h post-exposure). Biochemical assessment of perchloric acid extracts of nodularin-treated rat livers were used to confirm the MRS results. In vivo EPR oximetry was used to monitor decreasing hepatic pO2 (approximately 2-fold from controls) 2-3 h following nodularin exposure. In vivo MR techniques (MRI, MRS and EPR oximetry) are able to highlight effects that may not have been evident in single end point studies, and are ideal methods to follow tissue injury progression in longitudinally, increasing the power of a study through repeated measures, and decreasing the number of animals to perform a similar study using histological or biochemical techniques.  相似文献   

14.
Although magnetic resonance imaging (MRI) is a useful technique, only a few studies have investigated the dynamic behavior of small subjects using MRI owing to constraints such as experimental space and signal amount. In this study, to acquire high-resolution continuous three-dimensional gravitropism data of pea (Pisum sativum) sprouts, we developed a small-bore MRI signal receiver coil that can be used in a clinical MRI and adjusted the imaging sequence. It was expected that such an arrangement would improve signal sensitivity and improve the signal-to-noise ratio (SNR) of the acquired image. All MRI experiments were performed using a 3.0-T clinical MRI scanner. An SNR comparison using an agarose gel phantom to confirm the improved performance of the small-bore receiver coil and an imaging experiment of pea sprouts exhibiting gravitropism were performed. The SNRs of the images acquired with a standard 32-channel head coil and the new small-bore receiver coil were 5.23±0.90 and 57.75±12.53, respectively. The SNR of the images recorded using the new coil was approximately 11-fold higher than that of the standard coil. In addition, when the accuracy of MR imaging that captures the movement of pea sprout was verified, the difference in position information from the optical image was found to be small and could be used for measurements. These results of this study enable the application of a clinical MRI system for dynamic plant MRI. We believe that this study is a significant first step in the development of plant MRI technique.  相似文献   

15.
Two mono-substituted manganese polyoxometalates, K(6)MnSiW(11)O(39) (MnSiW(11)) and K(8)MnP(2)W(17)O(61) (MnP(2)W(17)), have been evaluated by in vivo and in vitro experiments as the candidates of potential tissue-specific contrast agents for magnetic resonance imaging (MRI). T1-relaxivities of 12.1mM(-1)s(-1) for MnSiW(11) and 4.7 mM(-1)s(-1) for MnP(2)W(17) (400 MHz, 25 degrees C) were higher than or similar to that of the commercial MRI contrast agent (GdDTPA). Their relaxivities in BSA and hTf solutions were also reported. After administration of MnSiW(11) and MnP(2)W(17) to Wistar rats, MR imaging showed longer and remarkable enhancement in rat liver and favorable renal excretion capability. The signal intensity increased by 74.0+/-4.9% for the liver during the whole imaging period (90 min) and by 67.2+/-5.3% for kidney within 20-70 min after injection at 40+/-3 micromol kg(-1) dose for MnSiW(11). MnP(2)W(17) induced 71.5+/-15.1% enhancement for the liver in 10-45 min range and 73.1+/-3.2% enhancement for kidney within 5-40 min after injection at 39+/-3 micromol kg(-1) dose. In vitro and in vivo study showed MnSiW(11) and MnP(2)W(17) being favorable candidates as the tissue-specific contrast agents for MRI.  相似文献   

16.
Animal studies have found that deficits in brain docosahexaenoic acid (DHA, 22:6n-3) accrual during perinatal development leads to transient and enduring abnormalities in brain development and function. Determining the relevance of this evidence to brain disorders in humans has been hampered by an inability to determine antimortem brain DHA levels and limitations associated with a postmortem approach. Accordingly, there is a need for alternate or complementary approaches to better understand the role of DHA in cortical function and pathology, and conventional magnetic resonance imaging (MRI) techniques may be ideally suited for this application. A major advantage of neuroimaging is that it permits prospective evaluation of the effects of manipulating DHA status on both clinical and neuroimaging variables. Emerging evidence from MRI studies suggest that greater DHA status is associated with cortical structural and functional integrity, and suggest that reduced DHA status and abnormalities in cortical function observed in psychiatric disorders may be interrelated phenomenon. Preliminary evidence from animal MRI studies support a critical role of DHA in normal brain development. Neuroimaging research in both human and animals therefore holds tremendous promise for developing a better understanding of the role of DHA status in cortical function, as well as for elucidating the impact of DHA deficiency on neuropathological processes implicated in the etiology and progression of neurodevelopmental and psychiatric disorders.  相似文献   

17.
Clinical applications of nuclear magnetic resonance (NMR) imaging have demonstrated its great potential for noninvasive examinations of soft tissues. Here preliminary experiments are reported on mummified human tissue by means of NMR cross-sectional and transmission imaging. For this purpose the natural viscosity of the tissues has been lowered by rehydration with an aqueous solution of 20% acetone.  相似文献   

18.
19.
Magnetic resonance imaging (MRI) has considerably improved the diagnosis and monitoring of multiple sclerosis (MS). Conventional MRI such as T2-weighted and gadolinium-enhanced T1-weighted sequences detect focal lesions of the white matter, damage of the blood–brain barrier, and tissue loss and inflammatory activity within lesions. However, these conventional MRI metrics lack the specificity required for characterizing the underlying pathophysiology, especially diffuse damage occurring throughout the whole central nervous system. To overcome these limitations, advanced MRI techniques have been developed to get more sensitive and specific parameters of focal and diffuse brain damage. Among these techniques, magnetization transfer imaging, diffusion MRI, functional MRI, and magnetic resonance spectroscopy are the most significant. In this article, we provide an overview of these advanced MRI techniques and their contribution to the better characterization and understanding of MS.  相似文献   

20.
Molecular magnetic resonance imaging with targeted contrast agents   总被引:6,自引:0,他引:6  
Magnetic resonance imaging (MRI) produces high-resolution three-dimensional maps delineating morphological features of the specimen. Differential contrast in soft tissues depends on endogenous differences in water content, relaxation times, and/or diffusion characteristics of the tissue of interest. The specificity of MRI can be further increased by exogenous contrast agents (CA) such as gadolinium chelates, which have been successfully used for imaging of hemodynamic parameters including blood perfusion and vascular permeability. Development of targeted MR CA directed to specific molecular entities could dramatically expand the range of MR applications by combining the noninvasiveness and high spatial resolution of MRI with specific localization of molecular targets. However, due to the intrinsically low sensitivity of MRI (in comparison with nuclear imaging), high local concentrations of the CA at the target site are required to generate detectable MR contrast. To meet these requirements, the MR targeted CA should recognize targeted cells with high affinity and specificity. They should also be characterized by high relaxivity, which for a wide variety of CA depends on the number of contrast-generating groups per single molecule of the agent. We will review different designs and applications of targeted MR CA and will discuss feasibility of these approaches for in vivo MRI.  相似文献   