首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The influence of the different lumbar spinal ligaments on intersegmental rotation is not fully understood. In order to explore this effect, a finite element model of the functional spinal unit L3/L4 was loaded with pure moments in the three main anatomic planes. The two extremes--minimum and maximum--ligament stiffness values reported in the literature were applied. After virtual transection of each of the spinal ligaments in turn, the intersegmental rotation and forces in the remaining ligaments were calculated. On flexion, the highest force was found for the posterior longitudinal ligament; on extension and lateral bending for the anterior longitudinal ligament; and on axial rotation for the facet capsular ligament. The strongest influence on intersegmental rotation is exerted by the interspinous ligament on flexion, by the anterior longitudinal ligament on extension and lateral bending, and by the facet capsular ligaments on axial rotation. Ligament stiffness has a strong influence on intersegmental rotation and forces in the ligaments, so that finite element models of spinal segments must be validated by experimental data. This study should help to elucidate the role of the various ligaments.  相似文献   

2.
Ligament mechanical behavior is primarily regulated by fibrous networks of type I collagen. Although these fibrous networks are typically highly aligned, healthy and injured ligament can also exhibit disorganized collagen architecture. The objective of this study was to determine whether variations in the collagen fibril network between neighboring ligaments can predict observed differences in mechanical behavior. Ligament specimens from two regions of bovine fetlock joints, which either exhibited highly aligned or disorganized collagen fibril networks, were mechanically tested in uniaxial tension. Confocal microscopy and FiberFit software were used to quantify the collagen fibril dispersion and mean fibril orientation in the mechanically tested specimens. These two structural parameters served as inputs into an established hyperelastic constitutive model that accounts for a continuous distribution of planar fibril orientations. The ability of the model to predict differences in the mechanical behavior between neighboring ligaments was tested by (1) curve fitting the model parameters to the stress response of the ligament with highly aligned fibrils and then (2) using this model to predict the stress response of the ligament with disorganized fibrils by only changing the parameter values for fibril dispersion and mean fibril orientation. This study found that when using parameter values for fibril dispersion and mean fibril orientation based on confocal imaging data, the model strongly predicted the average stress response of ligaments with disorganized fibrils (\(R^{2}=0.97\)); however, the model only successfully predicted the individual stress response of ligaments with disorganized fibrils in half the specimens tested. Model predictions became worse when parameters for fibril dispersion and mean fibril orientation were not based on confocal imaging data. These findings emphasize the importance of collagen fibril alignment in ligament mechanics and help advance a mechanistic understanding of fibrillar networks in healthy and injured ligament.  相似文献   

3.
4.

Background

The periodontal ligament (PDL) plays a key role in alveolar bone remodeling and resorption during tooth movements. The prediction of tooth mobility under functional dental loads requires a deep understanding of the mechanical behavior of the PDL, which is a critical issue in dental biomechanics. This study was aimed to examine the mechanical behavior of the PDL of the maxillary central and lateral incisors from human. The experimental results can contribute to developing an accurate constitutive model of the human PDL in orthodontics.

Methods

The samples of human incisors were cut into three slices. Uniaxial tensile tests were conducted under different loading rates. The transverse sections (cervical, middle and apex) normal to the longitudinal axis of the root of the tooth were used in the uniaxial tensile tests. Based on a bilinear simplification of the stress–strain relations, the elastic modulus of the PDL was calculated. The values of the elastic modulus in different regions were compared to explore the factors that influence the mechanical behavior of the periodontal ligament.

Results

The obtained stress–strain curves of the human PDL were characterized by a bilinear model with two moduli (E1 and E2) for quantifying the elastic behavior of the PDL from the central and lateral incisors. Statistically significant differences of the elastic modulus were observed in the cases of 1, 3, and 5 N loading levels for the different teeth (central and lateral incisors). The results showed that the mechanical property of the human incisors’ PDLs is dependent on the location of PDL (ANOVA, P?=?0.022, P?<?0.05). The elastic moduli at the middle planes were greater than at the cervical and apical planes. However, at the cervical, middle, and apical planes, the elastic moduli of the mesial and distal site were not significantly different (ANOVA, P?=?0.804, P?>?0.05).

Conclusions

The values of elastic modulus were determined in the range between 0.607 and 4.274 MPa under loads ranging from 1 to 5 N. The elastic behavior of the PDL is influenced by the loading rate, tooth type, root level, and individual variation.
  相似文献   

5.
Mechanical insult to the median nerve caused by contact with the digital flexor tendons and/or carpal tunnel boundaries may contribute to the development of carpal tunnel syndrome. Since the transverse carpal ligament (TCL) comprises the volar boundary of the carpal tunnel, its mechanics in part govern the potential insult to the median nerve. Using unconfined compression testing in combination with a finite element-based optimization process, nominal stiffness measurements and first-order Ogden hyperelastic material coefficients (μ and α ) were determined to describe the volar/dorsal compressive behavior of the TCL. Five different locations on the TCL were tested, three of which were deep to the origins of the thenar and hypothenar muscles. The average (± standard deviation) low-strain and high-strain TCL stiffness values in compression sites outside the muscle attachment region were 3.6 N/mm (±2.7) and 28.0 N/mm (±20.2), respectively. The average stiffness values at compression sites with muscle attachments were notably lower, with low-strain and high-strain stiffness values of 1.2 N/mm (±0.5) and 9.7 N/mm (±4.8), respectively. The average Ogden coefficients for the muscle attachment region were 51.6 kPa (±16.5) for μ and 16.5 (±2.0) for α, while coefficients for the non-muscle attachment region were 117.8 kPa (±86.8) for μ and 17.2 (±1.6) for α. These TCL compressive mechanical properties can help inprove computational models, which can be used to provide insight into the mechanisms of median nerve injury leading to the onset of carpal tunnel syndrome symptoms.  相似文献   

6.
As life expectancy increases, age-related disorders and the search for related medical care will expand. Osteoporosis is the most frequent skeletal disease in this context with the highest fracture risk existing for vertebrae. The aging process is accompanied by systemic changes, with the earliest degeneration occurring in the intervertebral discs. The influence of various degrees of disc degeneration on the load transfer was examined using the finite element method. The effect of different possible alterations of the bone quality due to osteoporosis was simulated by adjusting the corresponding material properties and their distribution and several loadings were applied. An alteration of the load transfer, characterised by changed compression stiffness and strain distributions as well as magnitudes, due to osteoporotic bone and degenerated discs was found. When osteoporosis was simulated, the stiffness was substantially decreased, larger areas of the cancellous bone were subjected to higher strains and strain maxima were increased. Increasing ratios of transverse isotropy in the osteoporotic bone yielded smaller effects than reduced bone properties. Including a degenerated disc mainly altered the strain distribution. Combining osteoporosis and degenerated discs reduced the areas of cancellous bone subjected to substantial strain. Based on these results, it can be concluded that the definition of a healthy disc in osteoporotic spines might be considered as a worst-case scenario. One attempt to evaluate the progress of osteoporosis can be made by introducing increasing degrees of anisotropy. If several parameters in a model are changed to simulate degeneration, it should be pointed out how each individual definition influences the overall result.  相似文献   

7.
Goal, Scope and Background This paper describes the influence of the choice of the functional unit on the results of an environmental assessment of different battery technologies for electric and hybrid vehicles. Battery, hybrid and fuel cell electric vehicles are considered as being environmentally friendly. However, the batteries they use are sometimes said to be environmentally unfriendly. At the current state of technology different battery types can be envisaged: lead-acid, nickel-cadmium, nickel-metal hydride, lithium-ion and sodium-nickel chloride. The environmental impacts described in this paper are based on a life cycle assessment (LCA) approach. One of the first critical stages of LCA is the definition of an appropriate and specific functional unit for electric and hybrid vehicle application. Most of the known LCA studies concerning batteries were performed while choosing different functional units, although this choice can influence the final results. An adequate functional unit, allowing to compare battery technologies in their real life vehicle application should be chosen. The results of the LCA are important as they will be used as a decision support for the end-of-life vehicles directive 2000/53/EC (Official Journal of the European Communities L269/24 2000). As a consequence, a thorough analysis is required to define an appropriate functional unit for the assessment of batteries for electric vehicles. This paper discusses this issue and will mainly focus on traction batteries for electric vehicles. Main Features An overview of the different parameters to be considered in the definition of a functional unit to compare battery technologies for battery electric vehicle application is described and discussed. An LCA study is performed for the most relevant potential functional units. SimaPro 6 is used as a software tool and Eco-indicator 99 as an impact assessment method. The influence of the different selected functional units on the results (Eco-indicator Points) is discussed. The environmental impact of the different electric vehicle battery technologies is described. A sensitivity analysis illustrates the robustness of the obtained results. Results and Discussion Five main parameters are considered in each investigated functional unit: an equal depth of discharge is assumed, a relative number of batteries required during the life of the vehicle is calculated, the energy losses in the battery and the additional vehicle consumption due to the battery mass is included and the same lifetime distance target is taken into account. On the basis of the energy content, battery mass, number of cycles and vehicle autonomy three suitable functional units are defined: ‘battery packs with an identical mass’, ‘battery packs with an identical energy content’ and ‘battery packs with an identical one-charge range’. The results show that the differences in the results between these three functional units are small and imply less variation on the results than the other uncertainties inherent to LCA studies. On the other hand, the results obtained using other, less adequate, functional units can be quite different. Conclusions When performing an LCA study, it’s important to choose an appropriate functional unit. Most of the time, this choice is unambiguous. However, sometimes this choice is more complicated when different correlated parameters have to be considered, as it is the case for traction batteries. When using a realistic functional unit, the result is not influenced significantly by the choice of one out of the three suitable functional units. Additionally, the life cycle assessment allowed concluding that three electric vehicle battery technologies have a comparable environmental impact: lead-acid, nickel-cadmium and nickel-metal hydride. Lithium-ion and sodium-nickel chloride have lower environmental impacts than the three previously cited technologies when used in a typical battery electric vehicle application. Recommendations and Perspectives The article describes the need to consider all relevant parameters for the choice of a functional unit for an electric vehicle battery, as this choice can influence the conclusions. A more standardised method to define the functional unit could avoid these differences and could make it possible to compare the results of different traction battery LCA studies more easily.  相似文献   

8.
Measurement of a spinal motion segment stiffness matrix   总被引:3,自引:0,他引:3  
The six-degrees-of-freedom elastic behavior of spinal motion segments can be approximated by a stiffness matrix. A method is described to measure this stiffness matrix directly with the motion segment held under physiological conditions of axial preload and in an isotonic fluid bath by measuring the forces and moments associated with each of the six orthogonal translations and rotations. The stiffness matrix was obtained from the load-displacement measurements by linear least squares assuming a symmetric matrix. Results from a pig lumbar spinal motion segment in an isotonic bath, with and without a 500 N axial preload, showed a large stiffening effect with axial preload.  相似文献   

9.
Despite the significant role ligament viscoelasticity plays in functional spinal biomechanics, relatively few studies have been performed to develop constitutive models that explicitly characterize this complex behavior. Unfortunately, the application and interpretation of these previous models are limited due to the use of simplified (quasi-linear) viscoelastic formulations or characterization techniques that have been shown to affect the predictive accuracy of the fitted coefficients. In order to surmount these previous limitations, the current study presents the application of a novel fitting technique (applied to stress relaxation experiments) and nonlinear viscoelastic constitutive formulation to human cervical spine anterior longitudinal ligament (ALL), posterior longitudinal ligament (PLL) and ligamentum flavum (LF). The fitted coefficients were validated by quantifying the ability of the constitutive equation to predict an independent cyclic data set across multiple physiologic strain amplitudes and frequencies. The resulting validated constitutive formulation indicated that the strain-dependent viscoelastic behavior of the longitudinal ligaments (ALL and PLL) was dominated by both the short-term (t=0.1s) and the steady-state (as t→∞) behavior. Conversely, the LF exhibited consistent relaxation behavior across the investigated temporal spectrum. From these data, it can be hypothesized that the unique strain-dependent temporal behavior of these spinal ligaments may be a functional adaptation that minimizes muscular expenditure during quasi-static postures while maximizing structural stability of the spine during transient loading events.  相似文献   

10.
11.

Background

ACL reconstruction is recommended to improve function in subjects with ligament injuries. However, after surgery, some individuals are not able to return to their pre-injury functional level. The mechanisms related to this incapacity are not well understood.

Study design

Cross-sectional study.

Methods

Co-contraction levels were assessed in individuals who returned to their pre-injury functional level and in 10 individuals who were not able to return to full activity after unilateral ACL reconstruction. Electromyography of the vastus lateralis and biceps femoris muscles before and after sudden perturbations applied during the stance phase of walking was used to calculate co-contraction.

Results

The involved limb had lower co-contraction pre-perturbation than the non-involved limb in both groups (p = 0.049). The co-contraction level post-perturbation was significantly higher in the limited return group than in the full return group (p = 0.03).

Conclusion

Decreased co-contraction in the involved limb before perturbation may be caused by sensorial changes resulting from surgery or injury. Increased co-contraction levels observed in the limited return group after perturbation may be a compensatory mechanism to make up for possible decreased intrinsic stability of the knee joint.

Clinical relevance

Increased co-contraction after perturbation does not contribute to knee stability.  相似文献   

12.
The study focused on the influence of the implant material stiffness on stress distribution and micromotion at the interface of bone defect implants. We hypothesized that a low-stiffness implant with a modulus closer to that of the surrounding trabecular bone would yield a more homogeneous stress distribution and less micromotion at the interface with the bony bed. To prove this hypothesis we generated a three-dimensional, non-linear, anisotropic finite element (FE) model. The FE model corresponded to a previously developed animal model in sheep. A prismatic implant filled a standardized defect in the load-bearing area of the trabecular bone beneath the tibial plateau. The interface was described by face-to-face contact elements, which allow press fits, friction, sliding, and gapping. We assumed a physiological load condition and calculated contact pressures, shear stresses, and shear movements at the interface for two implants of different stiffness (titanium: E=110GPa; composite: E=2.2GPa). The FE model showed that the stress distribution was more homogeneous for the low-stiffness implant. The maximum pressure for the composite implant (2.1 MPa) was lower than for the titanium implant (5.6 MPa). Contrary to our hypothesis, we found more micromotion for the composite (up to 6 microm) than for the titanium implant (up to 4.5 microm). However, for both implants peak stresses and micromotion were in a range that predicts adequate conditions for the osseointegration. This was confirmed by the histological results from the animal studies.  相似文献   

13.
McBride HM 《Current biology : CB》2011,21(23):R949-R951
A new study uncovers a novel role for the endoplasmic reticulum in tethering mitochondria specifically at the tip of the growing bud in Saccharomyces cerevisiae. Mitochondrial anchoring to the bud tip requires the tethering factor Mmr1, and the link to the ER is coupled to the cell cycle through a phosphorylation-dependent mechanism.  相似文献   

14.
《Biophysical journal》2023,122(2):360-373
On-chip study of blood flow has emerged as a powerful tool to assess the contribution of each component of blood to its overall function. Blood has indeed many functions, from gas and nutrient transport to immune response and thermal regulation. Red blood cells play a central role therein, in particular through their specific mechanical properties, which directly influence pressure regulation, oxygen perfusion, or platelet and white cell segregation toward endothelial walls. As the bloom of in-vitro studies has led to the apparition of various storage and sample preparation protocols, we address the question of the robustness of the results involving cell mechanical behavior against this diversity. The effects of three conservation media (EDTA, citrate, and glucose-albumin-sodium-phosphate) and storage time on the red blood cell mechanical behavior are assessed under different flow conditions: cell deformability by ektacytometry, shape recovery of cells flowing out of a microfluidic constriction, and cell-flipping dynamics under shear flow. The impact of buffer solutions (phosphate-buffered saline and density-matched suspension using iodixanol/Optiprep) are also studied by investigating individual cell-flipping dynamics, relative viscosity of cell suspensions, and cell structuration under Poiseuille flow. Our results reveal that storing blood samples up to 7 days after withdrawal and suspending them in adequate density-matched buffer solutions has, in most experiments, a moderate effect on the overall mechanical response, with a possible rapid evolution in the first 3 days after sample collection.  相似文献   

15.
Chabre M  le Maire M 《Biochemistry》2005,44(27):9395-9403
Rhodopsin, the first purified G-protein-coupled receptor (GPCR), was characterized as a functional monomer 30 year ago, but dimerization of GPCRs recently became the new paradigm of signal transduction. It has even been claimed, on the basis of recent biophysical and biochemical studies, that this new concept could be extended to higher-order oligomerization. Here this view is challenged. The new studies of rhodopsin and other simple (class 1a) GPCRs solubilized in detergent are re-assessed and are compared to the earlier classical studies of rhodopsin and other membrane proteins solubilized in detergent. The new studies are found to strengthen rather than invalidate the conclusions of the early ones and to support a monomeric model for rhodopsin and other class 1a GPCRs. A molecular model is proposed for the functional coupling of a rhodopsin monomeric unit with a G-protein heterotrimer. This model should be valid even for GPCRs that exist as structural dimers.  相似文献   

16.
17.
18.
19.
20.
It is generally accepted that the periodontal ligament (PDL) plays a crucial role in transferring occlusal forces from the teeth to the alveolar bone. Studies using finite element analysis (FEA) have helped to better understand this role and show that the stresses and strains in the alveolar bone are influenced by whether and how PDL is included in FE models. However, when the overall distribution of stresses and strains in crania and mandibles are of interest, PDL is often not included in FE models, although little is known about how this affects the results. Here we study the effect of representing PDL as a layer of solid material with isotropic homogeneous properties in an FE model of a human mandible using a novel application of geometric morphometrics. The results show that the modelling of the PDL affects the deformation and thus strain magnitudes not only of the alveolar bone around the biting tooth, but that the whole mandible deforms differently under load. As a result, the strain in the mandibular corpus is significantly increased when PDL is included, while the strain in the bone beneath the biting tooth is reduced. These results indicate the importance of the PDL in FE studies. Thus we recommend that the PDL should be included in FE models of the masticatory apparatus, with tests to assess the sensitivity of the results to changes in the Young's modulus of the PDL material.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号