首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive method was developed for the simultaneous determination of omeprazole and its major metabolites 5-hydroxyomeprazole and omeprazole sulfone in human plasma by HPLC-electrospray mass spectrometry. Following liquid-liquid extraction HPLC separation was achieved on a ProntoSil AQ, C18 column using a gradient with 10 mM ammonium acetate in water (pH 7.25) and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH(+) ions, m/z 346 for omeprazole, m/z 362 for 5-hydroxy-omeprazole and omeprazol-sulfone and m/z 300 for the internal standard (2-{[(3,5-dimethylpyridine-2-yl)methyl]thio}-1H-benzimidazole-5-yl)methanol. The limit of quantification (LOQ) achieved with this method was 5 ng/ml for 5-hydroxyomeprazole and 10 ng/ml for omeprazole and omeprazole-sulfone using 0.25 ml of plasma. Intra- and inter-assay variability was below 11% over the whole concentration range from 5 to 250 ng/ml for 5-hydroxyomeprazol and from 10 to 750 ng/ml for omeprazole and omeprazole-sulfone. The method was successfully applied to the determination of pharmacokinetic parameters of esomeprazole and the two major metabolites after a single dose and under steady state conditions.  相似文献   

2.
A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of salidroside, a major active constituent from Rhodiola rosea L., in rat plasma using helicid as an internal standard. The method involves a simple single-step liquid-liquid extraction with n-butanol. The analytes were separated by isocratic gradient elution on a Shim-pack ODS (4.6 microm, 250 mmx2.0 mm i.d.) column and analyzed in selected ion monitoring (SIM) mode with a negative electrospray ionization (ESI) interface using the respective [M+Cl]- ions, m/z 335 for salidroside, m/z 319 for internal standard. The method was validated over the concentration range of 5-2000 ng/mL for salidroside. Within- and between-batch precision (R.S.D.%) were all within 6% and accuracy ranged from 96 to 112%. The lower limits of quantification was 5 ng/mL. The extraction recovery was on average 86.6% for salidroside. The validated method was used to study the pharmacokinetic profile of salidroside in rat plasma after intravenous and oral administration of salidroside. The bioavailability of salidroside in rats is 32.1%.  相似文献   

3.
An analytical method based upon liquid chromatography coupled to ion trap mass spectrometry (MS) detection with electrospray ionization interface has been developed for the simultaneous identification and quantification of droperidol and ondansetron in human plasma. The two drugs were isolated from 0.5 mL of plasma using a basic liquid-liquid extraction with diethyl ether/heptane (90/10, v/v) and tropisetron and haloperidol as internal standards, with satisfactory extraction recoveries. They were separated on a 5-μm C(18) Highpurity column (150 mm×2.1 mm I.D.) maintained at 30°C. The elution was achieved isocratically with a mobile phase of 2 mM HCOONH(4) pH 3.8 buffer/acetonitrile (60/40, v/v) at a flow rate of 200 μL/min. Data were collected either in full-scan MS mode at m/z 100-450 or in full-scan MS-MS mode, selecting the [M+H] (+) ion at m/z=294.0 for ondansetron, m/z=285.2 for tropisetron, m/z=380.0 for droperidol and m/z=376.0 for haloperidol. The most intense daughter ion of ondansetron (m/z=212.0) and droperidol (m/z=194.0) were used for quantification. Retention times for tropisetron, ondansetron, droperidol and haloperidol were 2.50, 2.61, 3.10 and 4.68 min, respectively. Calibration curves were linear for both compounds in the 0.50-500 ng/mL range. The limits of detection and quantification were 0.10 ng/mL and 0.50 ng/mL, respectively. The intra- and inter-assay precisions were lower than 6.4% and intra- and inter-assay recoveries were in the 97.6-101.9% range for the three 3, 30 and 300 ng/mL concentrations. This method allows simultaneous and rapid measurement of droperidol and ondansetron, which are frequently co-administrated for the prevention of postoperative nausea and vomiting.  相似文献   

4.
An HPLC-MS/MS method was developed for the determination of MK-0518 (raltegravir), an HIV integrase inhibitor, in human plasma over the concentration range of 2-1000 ng/mL. Stable isotope labeled (13)C(6)-MK-0518 was used as an internal standard. The sample preparation procedure utilized liquid-liquid extraction with hexane:methylene chloride in the 96-well format with a 200 microL plasma sample size. The compounds were chromatographed on an Ace C(18) (50 x 3.0 mm, 3 microm, titanium frits) column with 42.5/57.5 (v/v %) 0.1mM EDTA in 0.1% formic acid/methanol mobile phase at a flow rate of 0.5 mL/min. Multiple reaction monitoring of the precursor-to-product ion pairs for MK-0518 (m/z 445-->109) and (13)C(6)-MK-0518 (m/z 451-->367) on an Applied Biosystem API 4000 HPLC-MS/MS was used for quantitation. Intraday precision of standard curve concentrations in five different lots of control plasma was within 3.2%, while accuracy ranged from 94.8 to 106.8%. The mean extraction recovery of spiked plasma samples was 87%. Quality control (QC) samples were stored at -20 degrees C. Initial within day analysis showed QC accuracy within 7.5% of nominal with precision of 3.1% or less. The plasma QC samples were demonstrated to be stable for up to 23 months at -20 degrees C. The method described has been used to support over 18 clinical studies during Phase I through III of clinical development.  相似文献   

5.
An ultra-violet high-performance liquid chromatographic method was developed for the determination of sertindole, an atypical antipsychotic drug and its main metabolites dehydrosertindole and norsertindole, in human plasma. With a small sample volume, after a single-step liquid-liquid extraction, the compounds were separated on a reversed-phase XTerra RP(18) column, eluted with 45% of acetonitrile and 55% of ammonium acetate buffer (0.05 M, adjusted pH 8) and detected at 256 nm within 11 min. This method shows a good linearity for plasma concentration between 5-100 ng/ml and 100-1000 ng/ml, a good precision (inter and intra day CV < 11%) and a good inter-assay accuracy (bias < 11%). The limit of quantification concentration was 5 ng/ml. The absolute recovery of sertindole was higher than 99%. This rapid and sensitive method could be used for therapeutic drug monitoring as well as for overdose management.  相似文献   

6.
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with electrospray ionization (ESI) was developed and validated for the simultaneous determination of pitavastatin and its lactone in human plasma and urine. Following a liquid-liquid extraction, both the analytes and internal standard racemic i-prolact were separated on a BDS Hypersil C(8) column, using methanol-0.2% acetic acid in water (70: 30, v/v) as the mobile phase. The mass spectrometer was operated in multiple reaction monitoring (MRM) mode using the transition m/z 422.4-->m/z 290.3 for pitavastatin, m/z 404.3-->m/z 290.3 for pitavastatin lactone and m/z 406.3-->m/z 318.3 for the internal standard, respectively. Linear calibration curves of pitavastatin and its lactone were obtained in the concentration range of 1-200 ng/ml, with a lower limit of quantitation of 1 ng/ml. The intra- and inter-day precision values were less than 4.2%, and accuracies were between -8.1 and 3.5% for both analytes. The proposed method was utilized to support clinical pharmacokinetic studies of pitavastatin in healthy subjects following oral administration.  相似文献   

7.
A highly sensitive method for quantitation of tamsulosin in human plasma using 1-(2,6-dimethyl-3-hydroxylphenoxy)-2-(3,4-methoxyphenylethylamino)-propane hydrochloride as the internal standard (I.S.) was established using liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). After alkalization with saturated sodium bicarbonate, plasma were extracted by ethyl acetate and separated by HPLC on a C18 reversed-phase column using a mobile phase of methanol-water-acetic acid-triethylamine (620:380:1.5:1.5, v/v). Analytes were quantitated using positive electrospray ionization in a quadrupole spectrometer. LC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at m/z 228 for tamsulosin and m/z 222 for the I.S. Calibration curves, which were linear over the range 0.2-30 ng/ml, were analyzed contemporaneously with each batch of samples, along with low (0.5 ng/ml), medium (3 ng/ml) and high (30 ng/ml) quality control samples. The intra- and inter-assay variability ranged from 2.14 to 8.87% for the low, medium and high quality control samples. The extraction recovery of tamsulosin from plasma was in the range of 84.2-94.5%. The method has been used successfully to study tamsulosin pharmacokinetics in adult humans.  相似文献   

8.
A sensitive and simple method was developed for determination of the enantiomers of azelnidipine, (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, in human plasma using chiral liquid chromatography with positive ion atmospheric pressure chemical ionization tandem mass spectrometry. Plasma samples spiked with stable isotope-labeled azelnidipine, [(2)H(6)]-azelnidipine, as an internal standard, were processed for analysis using a solid-phase extraction in a 96-well plate format. The azelnidipine enantiomers were separated on a chiral column containing alpha(1)-acid glycoprotein as a chiral selector under isocratic mobile phase conditions. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, monitoring the transitions from m/z 583-->167 for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, and from m/z 589-->167 for [(2)H(6)]-azelnidipine. The standard curve was linear over the studied range (0.05-20 ng/mL), with r(2)>0.997 using weighted (1/x(2)) quadratic regression, and the chromatographic run time was 5.0 min/injection. The intra- and inter-assay precision (coefficient of variation), calculated from the assay data of the quality control samples, was 1.2-8.2% and 2.4-5.8% for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, respectively. The accuracy was 101.2-117.0% for (R)-(-)-azelnidipine and 100.0-107.0% for (S)-(+)-azelnidipine. The overall recoveries for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine were 71.4-79.7% and 71.7-84.2%, respectively. The lower limit of quantification for both enantiomers was 0.05 ng/mL using 1.0 mL of plasma. All the analytes showed acceptable short-term, long-term, auto-sampler and stock solution stability. Furthermore, the method described above was used to separately measure the concentrations of the azelnidipine enantiomers in plasma samples collected from healthy subjects who had received a single oral dose of 16 mg of azelnidipine.  相似文献   

9.
Glipizide and rosiglitazone are widely used to treat Type 2 diabetes. In order to investigate drug-drug protein binding interaction between glipizide and rosiglitazone, a method was developed and validated for simultaneously determining the free (unbound) fraction of glipizide and rosiglitazone in plasma employing equilibrium dialysis for the separation of free drug and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantitation. Post-dialysis human plasma or buffer samples of 0.2 ml were extracted using a liquid-liquid extraction procedure and analyzed by a high performance liquid chromatography electrospray tandem mass spectrometer system. The compounds were eluted isocratically on a Zorbax SB-Phenyl column, ionized using an atmospheric pressure electrospray ionization source and analyzed in positive ion mode with multiple reaction monitoring. The ion transitions monitored were m/z 446-->321 for glipizide, m/z 358-->135 for rosiglitazone, and m/z 271-->155 for tolbutamide (internal standard, IS). The chromatographic run time was 5 min per injection, with retention times of 2.3, 3.4 and 2.3 min for glipizide, rosiglitazone and IS, respectively. The calibration curves of glipizide and rosiglitazone were over the range of 1-2000 ng/ml (r(2)>0.9969) in the combined matrix of human plasma and isotonic sodium phosphate buffer (1:1, v/v). The inter-assay precision and accuracy of the quality control samples were <10.9% of coefficient of variability and >93.5% and 94.5% of nominal concentration for glipizide and rosiglitazone, respectively. The lower limit of quantitation of both glipizide and rosiglitazone was 1.0 ng/ml. Both glipizide and rosiglitazone bound to plasma protein extensively (>99% bound). Glipizide and rosiglitazone free fraction averaged 0.678+/-0.071 and 0.389+/-0.061%, respectively, at plasma concentration of 1000 ng/ml. This developed method proves reproducible and sensitive and its application to clinical samples is also reported.  相似文献   

10.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for simultaneous quantitation of dexamethasone palmitate and dexamethasone in human plasma was developed. After sample preparation by protein precipitation and liquid-liquid extraction, the analytes and internal standard (IS) were separated on a Venusil XBP-C8 column using gradient elution. Multiple reaction monitoring of dexamethasone palmitate, dexamethasone and IS used the precursor to product ion transitions at m/z 631.8-->373.1, m/z 393.2-->147.1 and m/z 264.2-->58.1, respectively. The method was linear over the ranges 1.5-1000ng/mL for dexamethasone palmitate and 2.5-250ng/mL for dexamethasone with intra- and inter-day precisions of <10% and accuracies of 100+/-7%. The assay was applied to a clinical pharmacokinetic study involving the injection of dexamethasone palmitate to healthy volunteers.  相似文献   

11.
Sensitive methods based on capillary gas chromatography (GC) with mass spectrometric (MS) detection in a selected-ion monitoring mode (SIM) for the determination of a cyclooxygenase II (COX-II) inhibitor (3-isopropoxy-4-(4-methanesulfonylphenyl)-5,5'-dimethyl-5H-furan-2-one, I) in human plasma, in two concentration ranges of 0.1-20 and 5-1000 ng/ml, are described. Following liquid-liquid extraction, the residue, after evaporation of the organic phase to dryness, was reconstituted in acetonitrile (20 l) and part of the extract (1 l) was analyzed by GC/MS/SIM. The drug (I) and internal standard (II) were separated on a 25 mx0.2 mm capillary column with HP Ultra 1 (100% dimethylpolysiloxane, 0.33 m) phase and analyzed by MS/SIM monitoring ions at m/z 237 and 282 for I and II, respectively. The standard curve was linear within the lower concentration range of 0.1-20 ng/ml and the lower limit of quantification (LLOQ) in plasma was 0.1 ng/ml. Intraday coefficients of variation (CV, n=5) were 8.9, 4.2, 5.7, 3.1, 1.9, 1.9, and 4.4% at 0.1, 0.2, 0.5, 1.0, 5.0, 10, and 20 ng/ml, respectively. The standard curve was also linear within the higher concentration range of 5-1000 ng/ml and the LLOQ in plasma was 5 ng/ml. Intraday coefficients of variation (CV, n=5) were all below 9% at all concentrations within the standard curve range. The accuracy for I in human plasma was 91-112% and the recovery of I and II was greater than 70% at all concentrations within both standard curve ranges. The details of the assay methodology are presented.  相似文献   

12.
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.  相似文献   

13.
An ultra sensitive method for the direct measurement of 9-(2-phosphonylmethoxyethyl)adenine (PMEA), an antiviral agent for hepatitis B, in human serum using high performance liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed. This method involves the addition of [13C]PMEA (contains 5 13C) as internal standard, the purification and enrichment by a MCX solid phase extraction (SPE) cartridge, and quantitative analysis using LC-MS/MS. The MS/MS is selected to monitor the m/z 272 --> 134 and m/z 277 --> m/z 139 transitions for PMEA and [13C]PMEA, respectively, using negative electrospray ionization. The MS/MS response is linear over a concentration of 0.1-10 ng/ml with a lower limit of quantitation (LLOQ) of 0.1 ng/ml. The mean inter-assay accuracy (%Bias) for quality control (QC) at 0.1, 0.25, 1.0, and 10 ng/ml are 10, 1.6, -0.8, and 0.0%, respectively. The mean inter-assay precision (%CV) for the corresponding QCs is 3.9, 3.8, 5.3, and 3.4%, respectively. The method has been used to determine PMEA concentration in human serum following a single oral administration of a PMEA pro-drug at dose of 10 and 30 mg.  相似文献   

14.
A sensitive method for the determination of carbamazepine and carbamazepine 10,11-epoxide in plasma is described, using high-performance liquid chromatographic separation with tandem mass spectrometry. Samples were purified using liquid-liquid extraction and separated on a Phenomenex Luna C18 5 microm. 150 x 2 mm column with a mobile phase consisting of acetonitrile, methanol and formic acid (0.1%) (10:70:20, v/v). Detection was performed by a Micromass Quattro Ultima mass spectrometer in the MRM mode (LC-MS-MS) using electro spray ionisation (ESI+), monitoring the transition of the protonated molecular ion for carbamazepine at m/z 237.05 and carbamazepine 10,11-epoxide at m/z 253.09 to the predominant ions of m/z 194.09 and 180.04, respectively. The mean recovery was 95% for carbamazepine and 101% for carbamazepine 10,11-epoxide, with a lower limit of quantification of 0.722 ng/ml for carbamazepine and 5.15 ng/ml for carbamazepine 10,11-epoxide, when using 0.5 ml plasma. This high-throughput method was used to quantify 230 samples per day, and is sufficiently sensitive to be employed in pharmacokinetic studies.  相似文献   

15.
A specific and sensitive quantitative assay has been developed using high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI-MS) for the simultaneous quantitation of the antitumor drug ifosfamide (IFM) and its two metabolites, N2-deschloroethylifosfamide (N2-DCE-IFM) and N3-deschloroethylifosfamide (N3-DCE-IFM) in microsomal medium. The analytes and the internal standard (cyclophosphamide) were isolated by ethylacetate extraction from rat liver microsomes. They were analysed on a Nucleosil C18 HD column (125 mm x 4 mm, 5 microm) using a step gradient with the mobile phase (2 mM ammonium formate and methanol). The HPLC-ESI-MS method used selected ion monitoring of ions m/z 199.1 Th and m/z 261.1 Th and was validated in the concentrations ranges of 100-5000 ng/mL for IFM and 50-2500 ng/mL for its N-deschloroethylated metabolites (DCE-IFM) with good accuracy and precision (CV less than 15%). The low limits of quantitation (LLOQ) were found at 50 ng/mL for N-deschloroethylated metabolites and at 100 ng/mL for the parent drug (IFM). The method was applied for the determination of ifosfamide and its N-deschloroethylated metabolites in rat microsomal incubations.  相似文献   

16.
Flurogestone (FGA) is a synthetic progesterone, with a progestational action higher than that of progesterone itself. It is intended for vaginal use in large animals to induce oestrus synchronization. A quantitative method for the analysis of flurogestone acetate (FGA) in ovine plasma by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has been developed. After the incorporation of megestrol acetate (MGA) as internal standard (IS) and followed by a liquid-liquid extraction from plasma, FGA and MGA were chromatographed using a reverse-phase HPLC column and detected by tandem mass spectrometry with a TurboIonSpray source. Multiple reaction-monitoring (MRM) mode was used for the quantitative determination of FGA in ovine plasma. The precursor ions [M+H](+) at m/z 407.2 and 385.1 for FGA and MGA, respectively, produced product ions at m/z 267.1/285.1 for FGA and m/z 267.1/224.0 for MGA. The validated concentration range was 0.2-5.0 ng/ml based on 500 microl plasma aliquots. The lower limit of quantitation was 0.2 ng/ml. Fully validated selectivity, accuracy, precision and reproducibility criteria for routine use in pharmacokinetic studies were demonstrated.  相似文献   

17.
A highly sensitive and specific LC-MS method was developed and validated for the quantification of digoxin in human plasma and urine using d5-dihydrodigoxin as internal standard (IS). The assay procedure involved extraction of digoxin and IS from human plasma with chloroform-isopropanol (95:5, v/v). Chromatogrphic separation was achieved on a Spherisorb ODS2 column using a gradient mobile phase with 5 mmol/L ammonium acetate in water with 1% acetic acid and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective [M+K](+) ions, m/z 819.4 for digoxin and m/z 826.4 for IS. The method was proved to be accurate and precise at linearity range of 0.12-19.60 ng/mL in plasma with a correlation coefficient (r(2)) of >or=0.9968 and 1.2-196.0 ng/mL in urine. The limit of quantification achieved with this method was 0.12 ng/mL in plasma and 1.2 ng/mL in urine. The intra- and inter-assay precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was successfully applied to a pharmacokinetic study in human volunteers following intravenous administration of digoxin.  相似文献   

18.
A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of metoprolol succinate (MPS) and amlodipine besylate (AM) using hydrochlorothiazide (HCTZ) as IS in human plasma. Both the drugs were extracted by simple liquid-liquid extraction with chloroform. The chromatographic separation was performed on a reversed-phase peerless basic C18 column with a mobile phase of methanol-water containing 0.5% formic acid (8:2, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The method was validated over the concentration range of 1-100ng/ml for MPS and 1-15ng/ml AM in human plasma. The MRM transition of m/z 268.10-103.10, m/z 409.10-334.20 and m/z 296.00-205.10 were used to measure MPS, AM and HCTZ (IS), respectively. This method was successfully applied to the pharmacokinetic study of fixed dose combination (FDC) of MPS and AM formulation product after an oral administration to Indian healthy human volunteers.  相似文献   

19.
An analytical method for the determination of benazepril and its active metabolite, benazeprilat, in human plasma by capillary gas chromatography-mass-selective detection, with their respective labelled internal standard, was developed and validated according to international regulatory requirements. After addition of the internal standards, the compounds were extracted from plasma by solid-phase extraction using automated 96-well plate technology. After elution, the compounds were converted into their methyl ester derivatives by means of a safe and stable diazomethane derivative. The methyl ester derivatives were determined by gas chromatography using a mass-selective detector at m/z 365 for benazepril and benazeprilat and m/z 370 for the internal standards. Intra- and inter-day accuracy and precision were found to be suitable over the range of concentrations between 2.50 and 1000 ng/mL.  相似文献   

20.
Tacrolimus (FK506) is a potent immunosuppressant widely used for organ transplantation patients while diltiazem (DTZ), a calcium-channel inhibitor, is often used in renal transplantation patients to prevent post-transplant hypertension. However, DTZ has a significant pharmacokinetic interaction with FK506. In this study, a rapid and sensitive ammonium-adduct based liquid chromatography-tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the simultaneous determination of FK506 and DTZ in human whole blood using ascomycin as the internal standard (IS). After extraction of the whole blood samples by ethyl acetate, FK506, DTZ and the IS were subjected to LC/MS/MS analysis using electro-spray positive-ion mode ionization (ESI(+)). Chromatographic separation was performed on a Hypersil BDS C18 column (50 mm x 2.1 mm, i.d., 3 microm). The MS/MS detection was conducted by monitoring the fragmentation of 821.7-->768.9 (m/z) for FK506, 415.5-->310.3 (m/z) for DTZ and 809.8-->757.0 (m/z) for IS. The method had a chromatographic running time of approximately 2 min and linear calibration curves over the concentrations of 0.5-200 ng/mL for FK506 and 2-250 ng/mL for DTZ. The recoveries of liquid-liquid extraction method were 58.3-62.6% for FK506 and 50.4-58.8% for DTZ. The lower limit of quantification (LLOQ) of the analytical method was 0.5 ng/mL for FK506 and 2 ng/mL for DTZ. The intra- and inter-day precision was less than 15% for all quality control samples at concentrations of 2, 10, and 50 ng/mL for FK506 and 5, 25, and 100 ng/mL for DTZ. The validated LC/MS/MS method has been successfully used to analyze the concentrations of FK506 and DTZ in whole blood samples from pharmacokinetic studies in renal transplanted patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号