首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background  

Electrocardiography remains the best diagnostic tool and therapeutic biomarker for a spectrum of pediatric diseases involving cardiac or autonomic nervous system defects. As genetic links to these disorders are established and transgenic mouse models produced in efforts to understand and treat them, there is a surprising lack of information on electrocardiograms (ECGs) and ECG abnormalities in neonate mice. This is likely due to the trauma and anaesthesia required of many legacy approaches to ECG recording in mice, exacerbated by the fragility of many mutant neonates. Here, we use a non-invasive system to characterize development of the heart rate and electrocardiogram throughout the growth of conscious neonate FVB/N mice.  相似文献   

2.

Background

Drosophila heart tube is a feasible model for cardiac physiological research. However, obtaining Drosophila electrocardiograms (ECGs) is difficult, due to the weak signals and limited contact area to apply electrodes. This paper presents a non-invasive Gallium-Indium (GaIn) based recording system for Drosophila ECG measurement, providing the heart rate and heartbeat features to be observed. This novel, high-signal-quality system prolongs the recording time of insect ECGs, and provides a feasible platform for research on the molecular mechanisms involved in cardiovascular diseases.

Methods

In this study, two types of electrode, tungsten needle probes and GaIn electrodes, were used respectively to noiselessly conduct invasive and noninvasive ECG recordings of Drosophila. To further analyze electrode properties, circuit models were established and simulated. By using electromagnetic shielded heart signal acquiring system, consisted of analog amplification and digital filtering, the ECG signals of three phenotypes that have different heart functions were recorded without dissection.

Results and Discussion

The ECG waveforms of different phenotypes of Drosophila recorded invasively and repeatedly with n value (n>5) performed obvious difference in heart rate. In long period ECG recordings, non-invasive method implemented by GaIn electrodes acts relatively stable in both amplitude and period. To analyze GaIn electrode, the correctness of GaIn electrode model established by this paper was validated, presenting accuracy, stability, and reliability.

Conclusions

Noninvasive ECG recording by GaIn electrodes was presented for recording Drosophila pupae ECG signals within a limited contact area and signal strength. Thus, the observation of ECG changes in normal and SERCA-depleted Drosophila over an extended period is feasible. This method prolongs insect survival time while conserving major ECG features, and provides a platform for electrophysiological signal research on the molecular mechanism involved in cardiac arrhythmia, as well as research related to drug screening and development.  相似文献   

3.
Real time electrocardiogram QRS detection using combined adaptive threshold   总被引:2,自引:0,他引:2  

Background  

QRS and ventricular beat detection is a basic procedure for electrocardiogram (ECG) processing and analysis. Large variety of methods have been proposed and used, featuring high percentages of correct detection. Nevertheless, the problem remains open especially with respect to higher detection accuracy in noisy ECGs  相似文献   

4.

Background  

Transthoracic defibrillation is the most common life-saving technique for the restoration of the heart rhythm of cardiac arrest victims. The procedure requires adequate application of large electrodes on the patient chest, to ensure low-resistance electrical contact. The current density distribution under the electrodes is non-uniform, leading to muscle contraction and pain, or risks of burning. The recent introduction of automatic external defibrillators and even wearable defibrillators, presents new demanding requirements for the structure of electrodes.  相似文献   

5.

Background

Automatic measurement becomes a preference, and indeed a necessity, when analyzing 1000 s of ECGs in the setting of either drug-inducing QT prolongation screening or genome-wide association studies of QT interval. The problem is that individual manufacturers apply different computerized algorithms to measure QT interval. We conducted a comparative study to assess the outcomes with different automated measurements of QT interval between ECG machine manufacturers and validated the related heart rate correction methods.

Methods and Results

Herein, we directly compared these different commercial systems using 10,529 Fukuda Denshi ECGs and 72,754 Nihon Kohden ECGs taken in healthy Japanese volunteers. Log-transformed data revealed an equal optimal heart rate correction formula of QT interval for Fukuda Denshi and Nihon Kohden, in the form of QTc = QT/RR−0.347. However, with the raw data, the optimal heart rate correction formula of QT interval was in the form of QTc = QT+0.156×(1-RR) for Fukuda Denshi and QTc = QT+0.152×(1-RR) for Nihon Kohden. After optimization of heart rate correction of QT interval by the linear regression model using either log-transformed data or raw data, QTc interval was ∼10 ms longer in Nihon Kohden ECGs than in those recorded on Fukuda Denshi machines. Indeed, regression analysis revealed that differences in the ECG machine used had up to a two-fold larger impact on QT variation than gender difference. Such an impact is likely to be of considerable importance when ECGs for a given individual are recorded on different machines in the setting of multi-institutional joint research.

Conclusions

We recommend that ECG machines of the same manufacturer should be used to measure QT and RR intervals in the setting of multi-institutional joint research. It is desirable to unify the computer algorithm for automatic QT and RR measurements from an ECG.  相似文献   

6.

Introduction

We describe initial validation of a new system for digital to analog conversion (DAC) and reconstruction of 12-lead ECGs. The system utilizes an open and optimized software format with a commensurately optimized DAC hardware configuration to accurately reproduce, from digital files, the original analog electrocardiographic signals of previously instrumented patients. By doing so, the system also ultimately allows for transmission of data collected on one manufacturer''s 12-lead ECG hardware/software into that of any other.

Materials and Methods

To initially validate the system, we compared original and post-DAC re-digitized 12-lead ECG data files (∼5-minutes long) in two types of validation studies in 10 patients. The first type quantitatively compared the total waveform voltage differences between the original and re-digitized data while the second type qualitatively compared the automated electrocardiographic diagnostic statements generated by the original versus re-digitized data.

Results

The grand-averaged difference in root mean squared voltage between the original and re-digitized data was 20.8 µV per channel when re-digitization involved the same manufacturer''s analog to digital converter (ADC) as the original digitization, and 28.4 µV per channel when it involved a different manufacturer''s ADC. Automated diagnostic statements generated by the original versus reconstructed data did not differ when using the diagnostic algorithm from the same manufacturer on whose device the original data were collected, and differed only slightly for just 1 of 10 patients when using a third-party diagnostic algorithm throughout.

Conclusion

Original analog 12-lead ECG signals can be reconstructed from digital data files with accuracy sufficient for clinical use. Such reconstructions can readily enable automated second opinions for difficult-to-interpret 12-lead ECGs, either locally or remotely through the use of dedicated or cloud-based servers.  相似文献   

7.
Real-time intelligent pattern recognition algorithm for surface EMG signals   总被引:1,自引:0,他引:1  

Background  

Electromyography (EMG) is the study of muscle function through the inquiry of electrical signals that the muscles emanate. EMG signals collected from the surface of the skin (Surface Electromyogram: sEMG) can be used in different applications such as recognizing musculoskeletal neural based patterns intercepted for hand prosthesis movements. Current systems designed for controlling the prosthetic hands either have limited functions or can only be used to perform simple movements or use excessive amount of electrodes in order to achieve acceptable results. In an attempt to overcome these problems we have proposed an intelligent system to recognize hand movements and have provided a user assessment routine to evaluate the correctness of executed movements.  相似文献   

8.

Background  

Monitoring of the electrocardiogram (ECG) in premature infants with conventional adhesive-backed electrodes can harm their sensitive skin. Use of an electrode belt prevents skin irritation, but the effect of belt pressure on respiratory function is unknown. A strain gauge sensor is described which measures applied belt tension.  相似文献   

9.

Background  

A sensitive, ubiquitously expressed tetracycline inducible system would be a valuable tool in mouse transgenesis. However, this has been difficult to obtain due to position effects observed at different chromosomal sites of transgene integration, which negatively affect expression in many tissues. The aim of this study was to test the utility of a mammalian methylation-free CpG island to drive ubiquitous expression of the sensitive doxycycline (Dox) inducible rtTA2S-M2 Tet-transactivator in transgenic mice.  相似文献   

10.

Background  

The survival of Salmonella enterica within the intracellular host niche requires highly co-ordinated expression of virulence effectors predominantly regulated by the SsrAB two-component regulatory system. S. enterica serovar Typhimurium mutants lacking the ssrAB genes are avirulent in mice, highlighting the importance of this regulatory system in vivo. Mutants lacking the gene encoding the alternative sigma factor σE (rpoE) are also highly attenuated for intracellular survival, pointing to a potential connection with the SsrAB regulatory system.  相似文献   

11.

Background  

Myoelectric control of a robotic manipulator may be disturbed by failures due to disconnected electrodes, interface impedance changes caused by movements, problems in the recording channel and other various noise sources. To correct these problems, this paper presents two fusing techniques, Variance Weighted Average (VWA) and Decentralized Kalman Filter (DKF), both based on the myoelectric signal variance as selecting criterion.  相似文献   

12.

Background  

Sigmodontinae, known as "New World rats and mice," is a large subfamily of Cricetidae for which we herein provide the first comprehensive investigation of the placenta.  相似文献   

13.

Background  

Shaker codes for a Drosophila voltage-dependent potassium channel. Flies carrying Shaker null or hypomorphic mutations sleep 3–4 h/day instead of 8–14 h/day as their wild-type siblings do. Shaker-like channels are conserved across species but it is unknown whether they affect sleep in mammals. To address this issue, we studied sleep in Kcna2 knockout (KO) mice. Kcna2 codes for Kv1.2, the alpha subunit of a Shaker-like voltage-dependent potassium channel with high expression in the mammalian thalamocortical system.  相似文献   

14.
15.

Background  

Dystonia musculorum (dt) is an autosomal recessive hereditary neuropathy with a characteristic uncoordinated movement and is caused by a defect in the bullous pemphigoid antigen 1 (BPAG1) gene. The neural isoform of BPAG1 is expressed in various neurons, including those in the central and peripheral nerve systems of mice. However, most previous studies on neuronal degeneration in BPAG1 -deficient mice focused on peripheral sensory neurons and only limited investigation of the autonomic system has been conducted.  相似文献   

16.

Background  

The importance of estrogen in regulation of fluid absorption and sperm maturation in the rodent epididymis has been established from studies on estrogen receptor-alpha knockout mice. However, functional studies on the role of estrogen in primate epididymis have been few. The main objective of this study was therefore to extend these observations and systematically analyze the presence and function of estrogen receptors in modulating the function of the primate epididymis, using the bonnet monkey (Macaca radiata) as a model system.  相似文献   

17.

Aims

In pre-hospital settings handled by paramedics, identification of patients with myocardial infarction (MI) remains challenging when automated electrocardiogram (ECG) interpretation is inconclusive. We aimed to identify those patients and to get them on the right track to primary percutaneous coronary intervention (PCI).

Methods and results

In the Rotterdam-Rijnmond region, automated ECG devices on all ambulances were supplemented with a modem, enabling transmission of ECGs for online expert interpretation. The diagnostic protocol for acute chest pain was modified and monitored for 1 year.Patients with an ECG that met the criteria for ST-elevation myocardial infarction (STEMI) were immediately transported to a PCI hospital. ECGs that did not meet the STEMI criteria, but showed total ST deviation ≥800?µv were transmitted for online interpretation by the ECG expert. Online supervision was offered as a service if ECGs showed conduction disorders, or had an otherwise ‘suspicious’ pattern according to the ambulance paramedics.We enrolled 1,076 patients with acute ischaemic chest pain who did not meet the automated STEMI criteria. Their mean age was 63 years; 64% were men. After online consultation, 735 (68%) patients were directly transported to a PCI hospital for further treatment. PCI within 90?min was performed in 115 patients.

Conclusion

During a 1-year evaluation of the modified pre-hospital triage protocol for patients with acute ischaemic chest pain, over 100 acute MI patients with an initially inconclusive ECG received primary PCI within 90?min. Because of these results, we decided to continue the operation of the modified protocol.
  相似文献   

18.

Background  

The cysteine and glycine rich protein 2 (CRP2) encoded by the Csrp2 gene is a LIM domain protein expressed in the vascular system, particularly in smooth muscle cells. It exhibits a bimodal subcellular distribution, accumulating at actin-based filaments in the cytosol and in the nucleus. In order to analyze the function of CRP2 in vivo, we disrupted the Csrp2 gene in mice and analysed the resulting phenotype.  相似文献   

19.
Anti-tumor therapy with macroencapsulated endostatin producer cells   总被引:1,自引:0,他引:1  

Background  

Theracyte is a polytetrafluoroethylene membrane macroencapsulation system designed to induce neovascularization at the tissue interface, protecting the cells from host's immune rejection, thereby circumventing the problem of limited half-life and variation in circulating levels. Endostatin is a potent inhibitor of angiogenesis and tumor growth. Continuous delivery of endostatin improves the efficacy and potency of the antitumoral therapy. The purpose of this study was to determine whether recombinant fibroblasts expressing endostatin encapsulated in Theracyte immunoisolation devices can be used for delivery of this therapeutic protein for treatment of mice bearing B16F10 melanoma and Ehrlich tumors.  相似文献   

20.

Background  

Yersinia outer protein (Yop) H is a secreted virulence factor of Yersinia enterocolitica (Ye), which inhibits phagocytosis of Ye and contributes to the virulence of Ye in mice. The aim of this study was to address whether and how YopH affects the innate immune response to Ye in mice.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号