首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method is described by which the measurement of the DNA content and the light scatter and the detection of a cervical carcinoma-associated antigen (CCA) of squamous epithelial cells can be simultaneously accomplished by flow cytometry (FCM). Cervicovaginal cellular samples obtained from 30 patients were analyzed by this method. Cell populations with an abnormal DNA content or with the presence of CCA were detected in 20 samples, 18 of which contained dysplastic cells as detected by routine cytologic screening. The remaining ten cases, which were interpreted as cytologically normal by routine screening, were also interpreted as normal by FCM analysis.  相似文献   

2.
BACKGROUND: Various protocols for estimation of telomere length in individual cells by flow cytometry using fluorescence in situ hybridization of fluorescently labeled peptide nucleic acid (PNA) probes (Flow-FISH) have been described. Combined analysis of telomere length and cell phenotype, however, remains difficult because few fluorochromes with suitable emission spectra tolerate the harsh conditions needed for DNA denaturation during hybridization of the telomere-specific PNA probe. We overcame these problems and developed a method for measuring telomere length in cell subsets characterized by the expression of two surface antigens. METHODS: Alexa Fluor 488 and Alexa Fluor 546 were used for cell surface staining. Antigen-antibody complexes were covalently cross-linked onto the cell membrane before Flow-FISH. Cells were hybridized with a PNA probe conjugated to cyanine 5 (Cy5). Hoechst 33342 (HO342) was added for determination of cellular DNA content. For assay standardization, we added an aliquot of a single batch of 1,301 cells to each sample as an internal control before hybridization with the PNA probe. Samples were prepared in duplicate and analyzed on a standard three-laser BD LSR flow cytometer. For assay validation, the same samples were analyzed in parallel to correlate the percentage of telomere length of the sample versus 1,301 control cells to the mean size of terminal restriction fragments (TRFs) of DNA as determined by Southern gel analysis. RESULTS: The method permitted clear identification of lymphocyte subsets in samples hybridized for Flow-FISH, with subset frequencies comparable to those of untreated samples. At a concentration of 10 nM, the Cy5-labeled telomere-specific PNA probe produced a bright fluorescence signal well separated from background. Addition of HO342 in low concentration did not interfere with Cy5 telomere fluorescence, produced adequate DNA histograms, and permitted clear identification of cell phenotype. The probe concentration of 10 nM also proved optimal for inclusion of 1,301 control cells for assay standardization. Telomere length estimations by the current method correlated highly with TRF calculations by Southern gel hybridization (r(2)= 0.9, P = 0.0003). Application of our protocol to the analysis of human CD8CD28 lymphocyte subsets showed that CD8(+bright)CD28(-) lymphocytes generally exhibit shorter telomeres than CD8(+bright)CD28(+) cells. These data concurred with previous results of telomere shortening in CD8(+)CD28(-) T cells that were obtained by using different techniques. CONCLUSIONS: The multiparameter Flow-FISH protocol permitted rapid determination of differences in telomere length in subpopulations characterized by two surface markers without prior cell separation.  相似文献   

3.
D W Houck  M R Loken 《Cytometry》1985,6(6):531-538
A method has been developed for correlating the presence of cell surface markers with bromodeoxyuridine (BrdUrd) uptake. We have found that paraformaldehyde fixation will maintain immunofluorescent cell surface staining through acid denaturation that is necessary for anti-BrdUrd reactivity to single-stranded DNA. In addition, the forward angle light scattering was maintained, even though the cells had been exposed to 2N HCl and detergent. The protocol was tested on three model systems: mouse thymus, a human cell line (CCRF-SB), and peripheral blood leukocytes. It was found that there was no specific loss of lymphocyte subsets.  相似文献   

4.
Summary The simultaneous measurement of protein and DNA content of yeast on a cell by cell basis is described. A problem associated with partially overlapping fluorescence emission bands of the two fluorochromes is discussed. The rapid flow cytometric assay will be useful to monitor cell growth in industrial fermentation processes.Abbreviations DNA Desoxyribonucleic acid - YEP yeast extract peptone - FITC fluorescein-iso-thiocyanate  相似文献   

5.
7-aminoactinomycin D (7-AMD) efficiently discriminates between cells in the G0 and G1 phases of the cell cycle (Stokke et al., Cancer Res. 48:6708, 1988). The fluorescence and light scatter of cells stained with 7-AMD, Hoechst 33258 (H33258), and fluorescein isothiocyanate (FITC)-labeled antibodies were measured by dual wavelength excitation flow cytometry (488 nm, ultraviolet). The H33258 fluorescence was found to reflect DNA content in the presence of 7-AMD, although energy transfer caused an approximately 50% reduction in H33258 fluorescence intensity. However, energy transfer was more pronounced in dead cells, permitting exclusion of such cells during analysis. The G0, G1, S, and G2 phases of the cell cycle could be identified in the 7-AMD versus H33258 fluorescence histograms, as was demonstrated with mitogen-stimulated B lymphocytes and a mixture of unstimulated B lymphocytes and a proliferating B-cell line. One hour fixation with paraformaldehyde was compatible with prefixation labeling of surface antigens with indirectly FITC-labeled antibodies as well as postfixation labeling of intracellular antigens. Studies of expression of some surface and nuclear activation-associated antigens confirmed that cell cycle-resolved antigen expression and the time course of appearance of such antigens could be assessed accurately. Phycoerythrin could be used to label a second antigen.  相似文献   

6.
M R Zocchi  F Marelli  A Poggi 《Cytometry》1990,11(8):883-887
We describe a method of two-color immunofluorescence staining which allows the simultaneous analysis of both cytoplasmic antigens and cell entry into the S/G2/M cell cycle phases. This analysis was performed on CD3(-)-activated thymocytes obtained from either highly purified CD1-CD3-CD4-CD8- cells or fresh thymus cell suspensions, stimulated with low doses of phorbol-12 myristate-13 acetate (0.5 ng/ml) and interleukin-2. On the 14th day under these culture conditions about 90% of thymocytes did not express CD3 antigen on the cell surface. CD3- cells were further purified by cell sorting, fixed in paraformaldehyde, and permeabilized with Nonidet-P40. Then these thymocytes were stained by indirect immunofluorescence with monoclonal antibodies identifying T cell-specific molecules (CD3, CD2, CD28, TCR alpha/beta, and TCR gamma/delta) and analyzed for DNA content. Interestingly, both CD3 and CD28 antigens were detectable in the cytoplasm of most cells (greater than 80%). Further, the majority of the thymocytes which had entered the S/G2/M phases of the cell cycle (20%) expressed intracellular CD3 and CD28 molecules and reacted with the anti-beta framework beta F1 monoclonal antibody. The relationship between the appearance of CD3 and other T cell markers in the cytoplasm, the cell cycle entry, and the thymocyte development is discussed.  相似文献   

7.
Z Hollander  M R Loken 《Cytometry》1988,9(5):485-490
In order to identify when cellular expansion occurs during hematopoietic maturation, a method was developed for the simultaneous analysis of one or two cell-surface antigens and DNA content on bone marrow cells while preserving their light-scatter properties. Proliferation in a population defined by light-scatter and surface-antigenic characteristics was assessed by measuring the percentage of cells in this population having more than 2C amount of DNA ("proliferation index"). Viable, low-density (1.077 g/cm3), bone marrow cells, stained with monoclonal antibodies conjugated with fluorescein or phycoerythrin, were fixed with paraformaldehyde and subsequently treated with the detergent, Tween 20. The UV-excitable DNA stain Hoechst 33342 was used to quantify DNA content in the cells without interference with immunofluorescence. A FACS IV flow cytometer was used, equipped with the first laser at 488 nm emitting for light scattering and immunofluorescence measurements and the second laser emitting at 360 nm for the Hoechst excitation. The Hoechst uptake was the same for all bone marrow populations, yielding a tight coefficient of variation (CV) (average 5.0%) for the G0/G1 DNA peak. This permitted high sensitivity of cell detection in S, G2, and M phases of the cell cycle, while preserving light-scattering properties of the cells and maintaining cell surface immunofluorescence. The lowest "proliferation index" detected using this technique was 0.08% in a sample obtained from a patient with chronic lymphocytic leukemia. Normal helper T lymphocytes in marrow had approximately 0.5% of the cells in S, G2, or M phase. We show that the erythroid lineage, in the adult normal bone marrow, is the most active in proliferation among all hematopoietic lineages.  相似文献   

8.
DNA content analysis of insect cell lines by flow cytometry   总被引:1,自引:0,他引:1  
The DNA content of insect cell lines (6 lepidoptera, 1 coleoptera and 1 diptera) was determined by flow cytometry. The DNA profiles of the 8 cell lines tested were different. They were characterized by the presence of several peaks (2 to 7) corresponding to different ploidy levels, by differences in the fluorescence intensity of each peak and by the proportion of cells in each peak. Two cell lines (Cf124 and BmN) were constituted of 2 distinct populations of cells. The DNA profiles of the cell lines were stable among the passages and during the length of time culture. This technique was demonstrated to be useful for the detection of mixed cell lines and nucleopolyhedrovirus cell infection, using Autographa californica MNPV. The flow cytometry gives interesting results on the cell cycle and the ploidy level; it appears as a good tool for insect cell lines characterization. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

9.
BACKGROUND: Analysis of the DNA cell cycle and glutathione content cannot be performed on viable cells, because the fluorescence emissions of the DNA-specific probe Hoechst 33342 and the glutathione-specific probe monobromobimane overlap completely. We decided to explore whether the emissions could be resolved by the singlet excited state lifetimes of the probes. METHODS: Viable cells were first incubated with Hoechst 33342 at 37 degrees C for 30 min and then with monobromobimane at room temperature for 10 min. Samples were excited with a sinusoidally modulated laser beam (10 MHz) in a flow cytometer. The Hoechst 33342 and monobromobimane lifetimes and fluorescence intensities were resolved by using phase-sensitive detectors. RESULTS: The observed singlet excited state lifetimes were 1.5 ns for Hoechst 33342 and 12 ns for monobromobimane. The glutathione (GSH) content was shown to increase as cells (GM130, HL60, U937) progressed through the cell cycle. However, after the data were corrected for differences in cell volume, it was found that the GSH concentration was constant throughout the cell cycle of the exponentially growing cells. CONCLUSIONS: Phase-resolved flow cytometry provides a means for the specific analysis of the GSH content/concentration as a function of the cell's position in the DNA cell cycle in viable cells.  相似文献   

10.
DNA analysis by flow cytometry   总被引:2,自引:0,他引:2  
Accurate quantification of DNA from cells of several species is possible with flow cytometry. When one species is used as a reference, cytometric readings from two or more different species can be compared to obtain relative percent DNA or DNA indices. Differences in DNA from the male and female of the same species also can be measured. The method allows rapid screening of chromosomal abnormalities among large clinical populations, and evaluation of errors of sex determination such as XY sex reversal.  相似文献   

11.
A method of two-colour immunofluorescence staining has been developed to allow the simultaneous analysis of both surface and cytoplasmic antigens. This involves the use of direct fluorochrome antibody conjugates for cell-surface antigen staining, followed by cell permeabilization and the staining of cytoplasmic antigens with biotinylated antibodies and streptavidin-fluorochrome conjugates. Fluorochrome-antibody conjugates bound to cell-surface epitopes were found not to be affected by the subsequent permeabilisation and cytoplasmic staining. This method was used to examine the surface phenotype of T cells expressing a cytoplasmic antigen, STA. STA is a unique determinant detected in activated human T cells by the monoclonal antibody K-1-21, which also recognizes a cross-reactive conformation-dependent epitope on human free kappa light chains. Cytometric analysis showed that STA is found in both Leu 2a+ cytotoxic/suppressor T cells and Leu 3a+ helper/inducer T cells but is not induced in the Leu 15+ population which contains suppressor T cells. STA was also shown to be an activation antigen in murine T cells.  相似文献   

12.
Ehrlich ascites tumor cells were permeabilized using low concentrations of digitonin, 8 micrograms/10(6) cells. Permeabilization was monitored by the assay of lactate dehydrogenase released into the incubation medium and of hexokinase partially bound to mitochondria. Integrity of the cellular organelles was unaffected as determined by assay of the mitochondrial enzyme glutamate dehydrogenase. Cells were stained with rhodamine 123 as a mitochondrial specific dye and propidium iodide/mithramycin as DNA specific dyes. The green fluorescence of bound rhodamine 123 versus red fluorescence of DNA in individual cells was analysed by dual parameter flow cytometry. Incubation of cells with inhibitors of mitochondrial energy metabolism, such as, potassium cyanide and carbonyl cyanide m-chlorophenylhydrazone abolished binding of rhodamine 123. Flow cytometric data allowed a correlation between cell position in the mitotic cycle with total mitochondrial activity. In addition, comparison of the characteristics of propidium iodide and ethidium bromide staining further elucidated the molecular basis of the staining with the positively-charged fluorescent dye rhodamine 123.  相似文献   

13.
Summary Ehrlich ascites tumor cells were permeabilized using low concentrations of digitonin, 8 g/106 cells. Permeabilization was monitored by the assay of lactate dehydrogenase released into the incubation medium and of hexokinase partially bound to mitochondria. Integrity of the cellular organelles was unaffected as determined by assay of the mitochondrial enzyme glutamate dehydrogenase. Cells were stained with rhodamine 123 as a mitochondrial specific dye and propidium iodide/mithramycin as DNA specific dyes. The green fluorescence of bound rhodamine 123 versus red fluorescence of DNA in individual cells was analysed by dual parameter flow cytometry. Incubation of cells with inhibitors of mitochondrial energy metabolism, such as, potassium cyanide and carbonyl cyanide m-chlorophenylhydrazone abolished binding of rhodamine 123. Flow cytometric data allowed a correlation between cell position in the mitotic cycle with total mitochondrial activity. In addition, comparison of the characteristics of propidium iodide and ethidium bromide staining further elucidated the molecular basis of the staining with the positively-charged fluorescent dye rhodamine 123.Abbreviations BSA bovine serum albumin - CCCP carbonyl cyanide m-chlorophenylhydrazone - EAT Ehrlich ascites tumor - EGTA ethylene glycol bis (-aminoethylether) N,N,N,N-tetraacetic acid - Hepes 4-(2-hydroxyethyl)-1-piperazineethansulfonic acid - IM incubation medium - Rh 123 rhodamine 123 Dedicated to Professor K.J. Netter on the occasion of his 60th birthday Enzymes: Ribonuclease (EC 3.1.27.5), Hexokinase (EC 2.7.1.1), Glutamate dehydrogenase (EC 1.4.1.2), Lactate dehydrogenase (EC 1.1.1.28)  相似文献   

14.
A method for the simultaneous measurement of cell surface components and nucleic acids (DNA and RNA) of human lymphocytes by flow cytometry has been developed, thereby providing a means of analyzing cell surface changes during the various phases of the cell cycle. Unfixed cells were coated with fluorescein-conjugated concanavalin A (F Con A) or surface antigen-specific antibody, fixed sequentially with paraformaldehyde and methanol, treated with specific nucleases, and then stained with propidium iodide. Neither portion of the procedure (cell surface staining, nucleic acid staining) interfered significantly with the other. Cell cycle phases of phytohemagglutinin-stimulated human lymphocytes as determined by this method were comparable with those identified by acridine orange staining. Cell cycle-specific blocking agents were used to additionally demonstrate the specificity of the staining procedure. Simultaneous measurement of cell cycle phase and detection of surface receptors for Con A and T lymphocyte surface determinants was performed with this method.  相似文献   

15.
Recently, phosphospecific flow cytometry has emerged as a powerful tool to analyze intracellular signaling events in complex populations of cells because of its ability to simultaneously discriminate cell types based on surface marker expression and measure levels of intracellular phosphoproteins. This has provided novel insights into the cell- and pathway-specific nature of immune signaling. However, we and others have found that the fixation and permeabilization steps necessary for phosphoprotein analysis often negatively affect the resolution of cell types based on surface marker analysis and light scatter characteristics. Therefore, we performed a comprehensive profile of >35 different murine surface marker Abs to understand the effects of fixation and permeabilization on surface Ag staining. Fortuitously, approximately 80% of the Abs tested resolved cell populations of interest, although with decreased separation between positive and negative populations and at very different titers than those used on live cells. The other 20% showed either complete loss of separation between populations or loss of intermediately staining populations. We were able to rescue staining of several of these Ags by performing staining after fixation, but before permeabilization, although with limited fluorophore choices. Scatter characteristics of lymphocytes were well retained, but changed dramatically for monocyte and neutrophil populations. These results compile a comprehensive resource for researchers interested in applying phosphospecific flow cytometry to complex populations of cells while outlining steps necessary to successfully apply new surface marker Abs to this platform.  相似文献   

16.
Variations in total cellular protein content can confound interpretation of the significance of modulations of specific cellular proteins. In an effort to overcome this problem, a technique is described for the simultaneous measurement of a specific cellular protein, total cellular protein, and DNA content. The method utilizes dual-laser (uv and 488 nm) excitation and three fluorescent dyes: FITC, SR101, and DAPI. FITC-labelled antibody coupled with indirect immunofluorescence was used to quantify the c-myc oncoprotein, whereas SR101 and DAPI were used to measure total cellular protein and cellular DNA, respectively. Flow cytometric measurements of c-myc oncoprotein were compared to densitometric readings of p64c-myc. SR101 protein determinations were compared to those obtained by the Lowry technique. Results indicated that flow cytometric measurements correlated well with those obtained by the biochemical methods. The usefulness of the technique was further examined following treatment of exponentially growing HL-60 cells with 2.5 micrograms/ml cycloheximide for 0 to 12 h. Cycloheximide treatment was found to cause a significant decrease in c-myc oncoprotein content within 2 h (P less than 0.05), a relative increase in the proportion of G0/G1 cells and a modest decrease in total cellular protein. This technique appears to provide a rapid, quantitative approach, useful for investigating alterations in cellular growth balance occurring with cell differentiation, neoplastic transformation, or cell treatment with radiation or cytostatic drugs.  相似文献   

17.
The use of antibodies permits the study of oncogene product expression in cells and tissues. However, quantitation of the levels of expression in immunohistochemical preparations is beset by difficulties, and the available scoring system provide semiquantitative data at best. Here we describe the use of computer-assisted image analysis for determination of oncoprotein levels in a model system and compare the results with those generated by flow cytometric analysis. The oncogene products measured are located in the nucleus (c-myc p62 and c-fos p55), the inner surface of the membrane (c-ras p21), and both sides of the membrane (c-erbB-2 p185). In each instance, both analytic modalities yielded concordant results. Our data indicate that computer-assisted image analysis is a useful tool for quantitating cell components in immunohistochemical preparations.  相似文献   

18.
Estimation of nuclear DNA content of plants by flow cytometry   总被引:24,自引:0,他引:24  
A rapid and simple protocol for estimation of nuclear DNA content of plants is described. Suspensions of intact nuclei are prepared either by chopping plant tissues or lysing protoplasts in a MgSO4 buffer, mixed with DNA standards, and stained with propidium iodide in a solution containing DNAase-free RNAase. Fluorescence intensities of the stained nuclei are measured by a flow cytometer. Values for nuclear DNA content are estimated by comparing fluorescence intensities of the nuclei of the test population with those of appropriate internal DNA standards. The same procedure can also be used for rapid determination of ploidy in plant tissues.  相似文献   

19.
Estimation of nuclear DNA content of plants by flow cytometry   总被引:15,自引:6,他引:15  
The online version of the original article can be found at  相似文献   

20.
Estimation of nuclear DNA content of plants by flow cytometry   总被引:7,自引:1,他引:6  
The online version of the original article can be found at  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号