首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The determination of homocysteine-thiolactone in biological samples   总被引:3,自引:0,他引:3  
Homocysteine-thiolactone, a cyclic thioester of homocysteine, is synthesized by methionyl-tRNA synthetase in all cell types. A new assay for the determination of homocysteine-thiolactone in biological samples is described. The assay involves separation of homocysteine-thiolactone from macromolecules by ultrafiltration. Homocysteine-thiolactone is further purified and quantified by high-pressure liquid chromatography either on a reverse phase or a cation exchange micro-bore column. The detection and quantitation are obtained by monitoring the absorbance at 240 nm, a maximum in a UV spectrum of homocysteine-thiolactone. The sensitivity of detection is 5 pmol. This assay has been applied to bacteria (Escherichia coli and Mycobacterium smegmatis), the yeast Saccharomyces cerevisiae, cultured human vascular endothelial cells, and human plasma. The data support the conclusion that homocysteine-thiolactone is a ubiquitous metabolite whose levels are directly related to homocysteine levels.  相似文献   

2.
A simple, rapid and precise HPLC method has been developed for the assay of verapamil in human plasma. The clean up of the plasma samples was tested using several adsorbents for solid-phase extraction and best recovery was obtained using mixed-mode cartridges (HLB - hydrophilic-lipophilic balance) ranging between 94.70 and 103.71%. HPLC separation was performed with isocratic elution on Lichrospher 60 RP-select B column (250 mm × 4 mm I.D., 5 μm particle size). The mobile phase was 40% acetonitrile and 0.025 mol/L KH2PO4 with pH 2.5 at flow rate of 1 mL/min. Diltiazem was used as internal standard and the detection wavelength was 200 nm. The calibration curves were linear in the range of 10–500 ng/mL. The developed method is convenient for routine analysis of verapamil in human plasma.  相似文献   

3.
In present study, an HPLC method coupled with photodiode array detector (HPLC-PDA) was established for determination and pharmacokinetics of gastrodin (GAS) in human plasma after an oral administration of GAS capsule. In the method, ethanol and dichloromethane were respectively used for deproteinization and purification during the sample preparation procedure. Separation of GAS was achieved on an AichromBond-AQ C18 column (5 μm, 150 mm × 4.6 mm) with the mobile phase of methanol–0.1% phosphoric acid solution (2:98, v/v) at a flow rate of 0.8 ml/min. The wavelength was set at 220 nm and the injection volume was 20 μl. Under the conditions, the calibration curve was linear within the concentration range of 50–4000 ng/ml with the correlation coefficient (r) of 0.99554 (weight = 1/X2) and the lower limit of quantification (LLOQ) was 50 ng/ml. The inter- and intra-day precisions were less than 11% and the accuracies (%) were within the range of 95.55–103.78%. The extraction recoveries were over 65% with RSDs less than 5.50%. The GAS was proved to be stable under tested conditions. Thus, the method was valid enough to be applied for pharmacokinetic study of GAS in human plasma. The pharmacokinetic parameters of GAS in human plasma after an oral administration of 200 mg GAS capsule were described as: Cmax, 1484.55 ± 285.05 ng/ml; Tmax, 0.81 ± 0.16 h; t1/2α, 3.78 ± 2.33 h; t1/2β, 6.06 ± 3.20 h; t1/2Ka, 0.18 ± 0.53 h; K12, 0.18 ± 0.41/h; K21, 0.20 ± 0.16/h; K10, 4.11 ± 15.81/h; V1/F, 180.35 ± 89.44 L; CL/F, 62.50 ± 140.03 l/h; AUC0→t, 5619.41 ± 1972.88 (ng/ml) h; and AUC0→∞, 7210.26 ± 3472.74 (ng/ml) h, respectively. These will be useful for the clinical application of GAS.  相似文献   

4.
Based on the iso-peptidase activity of human plasma FXIII, a novel fluorometric assay that determines FXIII concentrations in human plasma below 0.05 IU/ml is introduced. We considered a peptide sequence derived from alpha(2)-antiplasmin (n =12) to yield high sensitivity. Peptide Abz-NE(Cad-Dnp)EQVSPLTLLK exhibits a K(m) value of 19.8+/-2.8 microM and is used in a concentration of 50 microM. The assay design is suitable for measurements in cuvettes (1 ml volume) as well as for the microtiter plate (MTP) format (0.2 ml volume). It provides linear dose-response curves over a wide range of FXIII concentrations (0.05-8.8 IU/ml). The assay was validated with respect to precision, detection and quantitation limits, accuracy/specificity, linearity, and range. A comparison of the fluorometric assay with the photometric assay for FXIII determinations in plasma pools as well as single donor plasma revealed suitability of the fluorometric assay for FXIII determination in plasma of healthy individuals. FXIII concentrations in plasma samples of patients with severe FXIII deficiency are discussed in the context of FXIII antigen levels. These assays correlate well in the critical range below 0.1 IU/ml, whereas the photometric assay may overestimate residual FXIII activity in severe FXIII-deficient patients.  相似文献   

5.
Pre-column derivatization with o-phthaldialdehyde and N-acetyl-l-cysteine was used for liquid-chromatographic diastereomeric resolution of p-hydroxymexiletine (PHM) and hydroxymethylmexiletine (HMM), metabolites of mexiletine formed by aromatic and aliphatic hydroxylation, respectively. The resulting diastereomeric derivatives were resolved on a C18 column and monitored by fluorescence detection. The diastereomeric elution order for both metabolites was determined on the basis of the circular dichroism spectra of each eluted fraction. Plasma samples (500 μl) showed recoveries greater than 75% for both the metabolites. Calibration curves in plasma samples were linear over the concentration ranges 10–500 and 20–1,000 ng/ml for each enantiomer of PHM and HMM, respectively. The limits of quantitation were found to be 10.0 and 5.0 ng/ml for both enantiomers of PHM and HMM. The within-day and between-day coefficients of variation were less than 10%. The assay was shown to be suitable for a pharmacokinetic study performed in a patient with ventricular arrhythmias following the short-term oral treatment of 200 mg t.i.d. of racemic mexiletine hydrochloride. Chirality 9:732–738, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

6.
The aim of this study is to investigate the effect of three cucurbitacins (Cuc) E, D and I on the bilirubin-albumin binding, both in human serum albumin (HSA) and in plasma. Bilirubin-HSA solution and plasma free of cucurbitacins were prepared as well as others containing serial concentrations of cucurbitacins. The concentration of unbound bilirubin was determined in bilirubin-HSA solution and the direct and total bilirubin concentrations were measured in plasma (with normal or elevated bilirubinemia) by Jendrassik and Grof method. In the conditions we adopted Cuc E and D (to a lesser extent), decreased the levels of unbound bilirubin in bilirubin-HSA solution and decreased direct bilirubin concentration and total bilirubin concentration in plasma in a dose-dependent manner while Cuc I had no effect. The effect of Cuc is related to the presence of native HSA. Thus, when albumin was absent or has been denatured by heating or by urea, Cuc E did not modify bilirubin levels, suggesting that the native structure of albumin is essential for such activity. The interaction of HSA with Cuc E was investigated by fluorescence spectroscopy. Cuc E increased the intrinsic fluorescence of the protein and the magnitude of fluorescence intensity of bilirubin-albumin complex. We concluded that Cuc E and D produced a rearrangement in the structure of albumin, particularly in the domain-II, resulting in an increase in the binding of bilirubin to albumin regardless to whether it's conjugated to glucuronic acid or unconjugated.  相似文献   

7.
An ultra-violet high-performance liquid chromatographic method was developed for the determination of sertindole, an atypical antipsychotic drug and its main metabolites dehydrosertindole and norsertindole, in human plasma. With a small sample volume, after a single-step liquid-liquid extraction, the compounds were separated on a reversed-phase XTerra RP(18) column, eluted with 45% of acetonitrile and 55% of ammonium acetate buffer (0.05 M, adjusted pH 8) and detected at 256 nm within 11 min. This method shows a good linearity for plasma concentration between 5-100 ng/ml and 100-1000 ng/ml, a good precision (inter and intra day CV < 11%) and a good inter-assay accuracy (bias < 11%). The limit of quantification concentration was 5 ng/ml. The absolute recovery of sertindole was higher than 99%. This rapid and sensitive method could be used for therapeutic drug monitoring as well as for overdose management.  相似文献   

8.
A simple, rapid, sensitive and specific ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method was developed and validated for the quantification of ethosuximide in human plasma is described. Analyte was chromatographed on a Hypersil Gold C18 column (100 mm × 2.1 mm, i.d., 1.9 μm) with isocratic elution at a flow rate of 0.250 mL/min and pravastatin was used as the internal standard. The assay involves a simple solid-phase extraction procedure of 0.25 mL human plasma and the analysis was performed on a triple-quadrupole tandem mass spectrometer by MRM mode via electrospray ionization (ESI). The method was linear in the concentration range of 0.25–60.0 μg/mL. The lower limit of quantification (LLOQ) was 0.25 μg/mL. The within- and between-day precision and accuracy of the quality control samples were within 10.0%. The recovery was 95.1% and 94.4% for ethosuximide and pravastatin, respectively. The analysis time for each sample was 1.8 min. The method was highly reproducible and gave peaks with excellent chromatography properties.  相似文献   

9.
A spectrofluorimetric method for the determination of eptifibatide is presented based on its native fluorescence. The type of solvent and the wavelength of maximum excitation and emission were carefully selected to optimize the experimental conditions. Under the specified experimental conditions, the linearities obtained between the emission intensity and the corresponding concentrations of eptifibatide were in the range 0.1–2.5 μg/ml for the calibration curve constructed for direct determination of eptifibatide in dosage form and 0.05–2.2 μg/ml for the calibration curve constructed in spiked human plasma with a good correlation coefficient (r > 0.99). The lower limit of quantification for the calibration curve constructed in human plasma was 0.05 μg/ml. Recovery results for eptifibatide in spiked plasma samples and in dosage form, represented as mean ± % RSD, were 95.17 ± 1.94 and 100.29 ± 1.33 respectively. The suggested procedures were validated according to the International Conference on Harmonization (ICH) guidelines for the direct determination of eptifibatide in its pure form and dosage form and United States Food and Drug Administration (US FDA) Guidance for Industry, Bioanalytical Method Validation for the assay of eptifibatide in human plasma.  相似文献   

10.
Nanoparticle (NP) exposure to biological fluids in the body results in protein binding to the NP surface, which forms a protein coating that is called the “protein corona”. To simplify studies of protein–NP interactions and protein corona formation, NPs are incubated with biological solutions, such as human serum or human plasma, and the effects of this exposure are characterized in vitro. Yet, how NP exposure to these two different biological milieus affects protein corona composition and cell response has not been investigated. Here, we explore the differences between the protein coronas that form when NPs are incubated in human serum versus human plasma. NP characterization indicated that NPs that were exposed to human plasma had higher amounts of proteins bound to their surfaces, and were slightly larger in size than those exposed to human serum. In addition, significant differences in corona composition were also detected with gel electrophoresis and liquid chromatography–mass spectrometry/mass spectrometry, where a higher fraction of coagulation proteins and complement factors were found on the plasma-exposed NPs. Flow cytometry and confocal microscopy showed that the uptake of plasma-exposed NPs was higher than that of serum-exposed NPs by RAW 264.7 macrophage immune cells, but not by NIH 3T3 fibroblast cells. This difference is likely due to the elevated amounts of opsonins, such as fibrinogen, on the surfaces of the NPs exposed to plasma, but not serum, because these components trigger NP internalization by immune cells. As the human plasma better mimics the composition of the in vivo environment, namely blood, in vitro protein corona studies should employ human plasma, and not human serum, so the biological phenomena that is observed is more similar to that occurring in vivo.  相似文献   

11.
Pantoprazole is used as an anti-ulcer drug through inhibition of H(+), K(+)-adenosine 5(')-triphosphatase in gastric parietal cells. It reduces the gastric acid secretion regardless of the nature of stimulation. The use of differential pulse voltammetry for the determination of pantoprazole in pharmaceutical dosage forms and human plasma using a glassy carbon electrode has been examined. The best voltammetric response was reached for a glassy carbon electrode in Britton-Robinson buffer solution of pH 5.0 submitted to a scan rate of 20.0 mVs(-1) and a pulse amplitude of 50.0 mV. This electroanalytical procedure was able to determine pantoprazole in the concentration range 6.0 x 10(-6)-8.0 x 10(-4)M. Precision and accuracy of the developed method was checked with recovery studies. The limit of detection and limit of quantitation were found to be 4.0 x 10(-7) and 9.0 x 10(-7)M, respectively. Rapidity, precision, and good selectivity were also found for the determination of pantoprazole in pharmaceutical dosage forms and human plasma. For comparative purposes high-performance liquid chromatography with a diode array and UV/VIS detection at 290.0 nm determination also was developed.  相似文献   

12.
A microwave digestion procedure, followed by Inductively Coupled Argon Plasma Spectroscopy, is described for the determination of boron (B) in human plasma. The National Institute of Standards and Technology (NIST) currently does not certify the concentration of B in any substance. The NIST citrus leaves 1572 (CL) Standard Reference Material (SRM) and wheat flour 1567a (WF) were chosen to determine the efficacy of digestion. CL and WF values compare favorably to those obtained from an open-vessel, wet digestion followed by ICP, and by neutron activation and mass spectrometric measurements. Plasma samples were oxidized by doubled-distilled ultrapure HNO3 in 120 mL PFA Teflon vessels. An MDS-81D microwave digestion procedure allows for rapid and relatively precise determination of B in human plasma, while limiting handling hazards and sources of contamination.  相似文献   

13.
A new method based on fluorescence derivatization with 5‐(dimethylamino) naphthalene‐1‐sulfonyl chloride (dansyl chloride) was developed for the quantitative determination of galantamine in human plasma and urine using high‐performance liquid chromatography. The reaction between galantamine and dansyl chloride was optimally realized in 30 min at room temperature and pH 10.5, with a reagent to galantamine molar ratio of 2.13. The derivative was extracted with dichloromethane, and the extract was dried under a nitrogen stream and dissolved in the mobile phase. Chromatographic analysis was performed with an Inertsil C18 column and a mobile phase comprising 40% acetonitrile and 60% 10 mM o‐phosphoric acid, 1.2 ml/min. The injection volume was 20 μl. The derivatives were detected with a fluorescence detector (excitation 375 nm/emission 537 nm). The retention time for the dansyl derivative of galantamine was 16.8 min. Linearity was observed between 125 and 2000 ng/ml in water, urine and plasma. The limit of detection and limit of quantification for the developed method were 6.27–70.99 and 18.81–212.97 ng/ml, respectively. Per cent recovery was calculated as 95.15 for urine and 95.78 for plasma. Interday repeatability values for urine and plasma samples (n = 6) at three different concentrations were calculated as a per cent relative standard deviation of 0.24–0.59 and 0.35–0.56. The corresponding per cent relative standard deviation values for intraday repeatability were 0.13–0.51 and 0.04–0.15, respectively.  相似文献   

14.
Adaptation of the Griess reaction for detection of nitrite in human plasma   总被引:1,自引:0,他引:1  
The determination of nitrite in human plasma or serum has been most frequently used as a marker of nitric oxide (NO) production. In addition, it has recently been suggested that nitrite could act as a vasodilating agent at physiological concentrations by NO delivery. Therefore, nitrite determination in biological fluids is becoming increasingly important. The most frequently used method to measure nitrite is based on the spectrophotometric analysis of the azo dye obtained after reaction with the Griess reagent. This method has some limitations regarding detection limit and sensitivity, thus resulting unsuitable for nitrite detection in plasma. We have identified some drawbacks and modified the original procedure to overcome these problems. By the use of the newly developed method, we measured 221±72 nM nitrite in human plasma from healthy donors.  相似文献   

15.
A sensitive, simple and feasible method has been developed and validated for the simultaneous determination of three diastereoisomers of hexabromocyclododecane (HBCD) in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS). The simple pretreatment generally involved protein precipitation with methanol (MeOH). The separation was performed with a C18 reverse phase column. The mobile phases were 5mM ammonium acetate (NH(4)AC) in water and acetonitrile (ACN). The mass spectrometer was operated using negative electrospray ionization (ESI) source and the data acquisition was carried out with multiple reaction monitoring (MRM) mode. The analyte quantifications were performed by external standard method with matrix-matched calibration curves. The method was partially validated with the evaluations of accuracy, precision, linearity, limit of quantification (LOQ), limit of detection (LOD), recovery, matrix effect and carryover effect. With the present method, the intra-batch accuracies were 94.7-104.3%, 91.9-109.3% and 89.8-105.0% for α-, β- and γ-HBCD, respectively. And the inter-batch accuracies were ranged from 94.2% to 109.7%. Both intra-batch and inter-batch precisions (relative standard deviation, RSD, %) of the analytes were no more than 11.2%. The recoveries were from 79.0% to 108.9% and the LOQ was 10pg/mL for each diastereoisomer. The linear range was 10-10,000pg/mL with the linear correlation coefficient R(2)>0.996. No significant matrix effect and carryover effect of the analytes were observed in this study. This method is in possession of sufficient resolution, high sensitivity as well as selectivity and convenient to be applied to the trace determination of HBCDs in human plasma.  相似文献   

16.
A sensitive, selective and high throughput liquid chromatography tandem mass spectrometry (LC–ESI-MS/MS) method has been developed for the determination of teriflunomide, an active metabolite of leflunomide in human plasma. Plasma samples were prepared by liquid–liquid extraction of teriflunomide and valsartan as internal standard (IS) in ethyl acetate from 200 μL human plasma. The chromatographic separation was achieved on an Inertsil ODS-3 C18 (50 mm × 4.6 mm, 3 μm) analytical column using isocratic mobile phase, consisting of 20 mM ammonium acetate–methanol (25:75, v/v), at a flow-rate of 0.8 mL/min. The precursor → product ion transition for teriflunomide (m/z 269.0 → 82.0) and IS (m/z 434.1 → 350.3) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) and negative ion mode. The method was validated over a wide dynamic concentration range of 10.1–4001 ng/mL. Matrix effect was assessed by post-column infusion experiment and the mean process efficiency were 91.7% and 88.2% for teriflunomide and IS respectively. The method was rugged and rapid with a total run time of 2.0 min and is applied to a bioequivalence study of 20 mg leflunomide (test and reference) tablet formulation in 12 healthy Indian male subjects under fasting condition.  相似文献   

17.
We developed and validated a sensitive and convenient high-performance liquid chromatography (HPLC) method for the specific determination of ketone bodies (acetoacetate and d-3-hydroxybutyrate) in human plasma. p-Nitrobenzene diazonium fluoroborate (diazo reagent) was used as a precolumn derivatization agent, and 3-(2-hydroxyphenyl) propionic acid was used as an internal standard. After the reaction, excess diazo reagent and plasma proteins were removed by passing through a solid-phase cartridge (C18). The derivatives retained on the cartridge were eluted with methanol, introduced into the HPLC system, and then detected with UV at 380 nm. A calibration curve for acetoacetate standard solution with a 20-μl injection volume showed good linearity in the range of 1 to 400 μM with a 0.9997 correlation coefficient. For the determination of d-3-hydroxybutyrate, it was converted to acetoacetate before reaction with the diazo reagent by an enzymatic coupling method using d-3-hydroxybutyrate dehydrogenase and lactate dehydrogenase. A calibration curve for d-3-hydroxybutyrate standard solution also showed good linearity in the range of 1.5 to 2000 μM with a 0.9988 correlation coefficient. Analytical recoveries of acetoacetate and d-3-hydroxybutyrate in human plasma were satisfactory. The method was successfully applied to samples from diabetic patients, and results were consistent with those obtained using the thio-NAD enzymatic cycling method used in clinical laboratories.  相似文献   

18.
A selective, rapid and sensitive hydrophilic interaction liquid chromatography–tandem mass spectrometry (HILIC–MS/MS) method was developed for the first time to determine adefovir in human plasma and applied to a pharmacokinetic study. Plasma samples were prepared by protein precipitation with methanol followed by a further cleaning using dichloromethane. The chromatographic separation was carried out on an ACQUITY UPLC™ BEH HILIC column with the mobile phase of methanol–water–formic acid (85:15:0.2, v/v/v). The detection was performed on a triple-quadrupole tandem mass spectrometer with multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. The method was rapid with a run time of 3 min per sample. The linear calibration curves were obtained in the concentration range of 1.02–102 ng/mL (r2 ≥ 0.99) with the lower limit of quantification (LLOQ) of 1.02 ng/mL. The intra- and inter-day precision (relative standard deviation, R.S.D.) values were below 12% and the accuracy (relative error, R.E.) was from 0.6% to 3.2% at all quality control (QC) levels. The method was applicable to clinical pharmacokinetic study of adefovir in healthy volunteers after oral administration of adefovir dipivoxil tablet.  相似文献   

19.
Homocysteine (Hcy) is incorporated into protein via a reaction of the thioester Hcy–thiolactone with ε-amino group of a protein lysine residue. This reaction leads to impairment and alteration of protein’s function and has been implicated in atherothrombotic disease. However, the data regarding N-linked Hcy content in proteins are limited, mostly due to a lack of facile assays. Here I describe a new sensitive assay for the determination of protein N-linked Hcy and demonstrate its utility for individual proteins and biological fluids. N-linked Hcy is liberated from proteins by acid hydrolysis and converted to Hcy–thiolactone, which is then purified and quantified by high-performance liquid chromatography on a cation exchange column. The quantification is by fluorescence after postcolumn derivatization with o-phthaldialdehyde. Using this assay, the levels of N-linked Hcy in individual pure proteins were found to vary from as high as 0.470–0.515 mol/mol protein for human and equine ferritins to as low as 0.00006 mol/mol protein for chicken lysozyme. Hemoglobins from a variety of species contained more N-linked Hcy than did corresponding albumins (0.0127–0.0828 vs. 0.0027–0.0086 mol/mol). Normal human plasma and milk were found to contain submicromolar concentrations of protein N-linked Hcy, whereas cow milk and whey contained micromolar concentrations of protein N-linked Hcy.  相似文献   

20.
For the determination of heptaminol (HEP) in its authentic and dosage form as well as in human plasma, a new simple, sensitive and cheap fluorimetric method of analysis was developed and validated. The presented method is based on the reaction between aliphatic primary amino moiety present in HEP with ninhydrin and phenylacetaldehyde using Torell and Stenhagen buffer at pH 8.2 that yields a highly fluorescent derivative which after excitation at 390 nm showed a fluorescence emission at 464 nm. The effects of various experimental factors on both the development and stability of the fluorescent product was evaluated and optimized. In the concentration range (0.5–6.0 μg/ml), the constructed calibration curve was linear with a good correlation coefficient (0.9997) and the calculated limit of detection (LOD) and limit of quantitation (LOQ) were 0.14 and 0.43 respectively. The presented method was successfully applied for determination of Corasore® tablets and validated according to ICH guidelines.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号