首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 172 毫秒
1.

Background

The objectives of this study were to evaluate the influence of iterative reconstruction (IR) on pulmonary nodule volumetry with chest computed tomography (CT).

Methods

Twenty patients (12 women and 8 men, mean age 61.9, range 32–87) underwent evaluation of pulmonary nodules with a 64-slice CT-scanner. Data were reconstructed using filtered back projection (FBP) and IR (Philips Healthcare, iDose4-levels 2, 4 and 6) at similar radiation dose. Volumetric nodule measurements were performed with semi-automatic software on thin slice reconstructions. Only solid pulmonary nodules were measured, no additional selection criteria were used for the nature of nodules. For intra-observer and inter-observer variability, measurements were performed once by one observer and twice by another observer. Algorithms were compared using the concordance correlation-coefficient (pc) and Friedman-test, and post-hoc analysis with the Wilcoxon-signed ranks-test with Bonferroni-correction (significance-level p<0.017).

Results

Seventy-eight nodules were present including 56 small nodules (volume<200 mm3, diameter<8 mm) and 22 large nodules (volume≥200 mm3, diameter≥8 mm). No significant differences in measured pulmonary nodule volumes between FBP, iDose4-levels 2, 4 and 6 were found in both small nodules and large nodules. FBP and iDose4-levels 2, 4 and 6 were correlated with pc-values of 0.98 or higher for both small and large nodules. Pc-values of intra-observer and inter-observer variability were 0.98 or higher.

Conclusions

Measurements of solid pulmonary nodule volume measured with standard-FBP were comparable with IR, regardless of the IR-level and no significant differences between measured volumes of both small and large solid nodules were found.  相似文献   

2.

Objective

To investigate the reproducibility of diffusion-weighted magnetic resonance imaging (DW-MRI) in assessing tumor response early in the course of neoadjuvant chemoradiotherapy in patients with operable esophageal cancer.

Methods

Eleven male patients (mean age 54.8 years) with newly diagnosed esophageal cancer underwent DW-MRI before and 10 days after start of chemoradiotherapy. Reproducibility of apparent diffusion coefficient (ADC) measurements by manual (freehand) and semi-automated volumetric methods was assessed.

Results

Interobserver reproducibility for the assessment of mean tumor ADC by the manual measurement method was good, with an ICC of 0.69 (95% CI, 0.36 to 0.85; P = 0.001). Interobserver reproducibility for the assessment of mean tumor ADC by the semi-automated volumetric measurement method was very good, with an ICC of 0.96 (95% CI, 0.91 to 0.98; P<0.001).

Conclusion

Semi-automated volumetric ADC measurements have higher reproducibility than manual ADC measurements in assessing tumor response to chemoradiotherapy in patients with esophageal adenocarcinoma.  相似文献   

3.

Purpose

To further elucidate retinal findings and retinal vessel changes in Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) patients by means of high resolution retinal imaging.

Methods

28 eyes of fourteen CADASIL patients and an equal number of control subjects underwent confocal scanning laser ophthalmoscopy (cSLO), spectral-domain optical coherence tomography (SD-OCT), retinal nerve fibre layer (RNFL) measurements, fluorescein and indocyanine angiography. Three vessel measurement techniques were applied: RNFL thickness, a semiautomatic software tool based on cSLO images and manual vessel outlining based on SD-OCT.

Results

Mean age of patients was 56.2±11.6 years. Arteriovenous nicking was present in 22 (78.6%) eyes and venous dilation in 24 (85.7%) eyes. Retinal volume and choroidal volume were 8.77±0.46 mm3 and 8.83±2.24 mm3. RNFL measurements showed a global increase of 105.2 µm (Control group: 98.4 µm; p = 0.015). Based on semi-automatic cSLO measurements, maximum diameters of arteries and veins were 102.5 µm (106.0 µm; p = 0.21) and 128.6 µm (124.4 µm; p = 0.27) respectively. Manual SD-OCT measurements revealed significantly increased mean arterial 138.7 µm (125.4 µm; p<0.001) and venous 160.0 µm (146.9; p = 0.003) outer diameters as well as mean arterial 27.4 µm (19.2 µm; p<0.001) and venous 18.3 µm (15.7 µm; p<0.001) wall thicknesses in CADASIL patients.

Conclusions

The findings reflect current knowledge on pathophysiologic changes in vessel morphology in CADASIL patients. SD-OCT may serve as a complementary tool to diagnose and follow-up patients suffering from cerebral small-vessel diseases.  相似文献   

4.

Background and Purpose

Reproducible segmentation of brain tumors on magnetic resonance images is an important clinical need. This study was designed to evaluate the reliability of a novel fully automated segmentation tool for brain tumor image analysis in comparison to manually defined tumor segmentations.

Methods

We prospectively evaluated preoperative MR Images from 25 glioblastoma patients. Two independent expert raters performed manual segmentations. Automatic segmentations were performed using the Brain Tumor Image Analysis software (BraTumIA). In order to study the different tumor compartments, the complete tumor volume TV (enhancing part plus non-enhancing part plus necrotic core of the tumor), the TV+ (TV plus edema) and the contrast enhancing tumor volume CETV were identified. We quantified the overlap between manual and automated segmentation by calculation of diameter measurements as well as the Dice coefficients, the positive predictive values, sensitivity, relative volume error and absolute volume error.

Results

Comparison of automated versus manual extraction of 2-dimensional diameter measurements showed no significant difference (p = 0.29). Comparison of automated versus manual segmentation of volumetric segmentations showed significant differences for TV+ and TV (p<0.05) but no significant differences for CETV (p>0.05) with regard to the Dice overlap coefficients. Spearman''s rank correlation coefficients (ρ) of TV+, TV and CETV showed highly significant correlations between automatic and manual segmentations. Tumor localization did not influence the accuracy of segmentation.

Conclusions

In summary, we demonstrated that BraTumIA supports radiologists and clinicians by providing accurate measures of cross-sectional diameter-based tumor extensions. The automated volume measurements were comparable to manual tumor delineation for CETV tumor volumes, and outperformed inter-rater variability for overlap and sensitivity.  相似文献   

5.

Objective

This study aimed to construct a model for using in differentiating benign and malignant nodules with the artificial neural network and to increase the objective diagnostic accuracy of US.

Materials and methods

618 consecutive patients (528 women, 161 men) with 689 thyroid nodules (425 malignant and 264 benign nodules) were enrolled in the present study. The presence and absence of each sonographic feature was assessed for each nodule - shape, margin, echogenicity, internal composition, presence of calcifications, peripheral halo and vascularity on color Doppler. The variables meet the following criteria: important sonographic features and statistically significant difference were selected as the input layer to build the ANN for predicting the malignancy of nodules.

Results

Six sonographic features including shape (Taller than wide, p<0.001), margin (Not Well-circumscribed, p<0.001), echogenicity (Hypoechogenicity, p<0.001), internal composition (Solid, p<0.001), presence of calcifications (Microcalcification, p<0.001) and peripheral halo (Absent, p<0.001) were significantly associated with malignant nodules. A three-layer 6-8-1 feed-forward ANN model was built. In the training cohort, the accuracy of the ANN in predicting malignancy of thyroid nodules was 82.3% (AUROC = 0.818), the sensitivity and specificity was 84.5% and 79.1%, respectively. In the validation cohort, the accuracy, sensitivity and specificity was 83.1%, 83.8% and 81.8%, respectively. The AUROC was 0.828.

Conclusion

ANN constructed by sonographic features can discriminate benign and malignant thyroid nodules with high diagnostic accuracy.  相似文献   

6.

Background and aims

The recently developed histological scoring system for non-alcoholic fatty liver disease (NAFLD) by the NASH Clinical Research Network (NASH-CRN) has been widely used in clinical settings, but is increasingly employed in preclinical research as well. However, it has not been systematically analyzed whether the human scoring system can directly be converted to preclinical rodent models. To analyze this, we systematically compared human NAFLD liver pathology, using human liver biopsies, with liver pathology of several NAFLD mouse models. Based upon the features pertaining to mouse NAFLD, we aimed at establishing a modified generic scoring system that is applicable to broad spectrum of rodent models.

Methods

The histopathology of NAFLD was analyzed in several different mouse models of NAFLD to define generic criteria for histological assessment (preclinical scoring system). For validation of this scoring system, 36 slides of mouse livers, covering the whole spectrum of NAFLD, were blindly analyzed by ten observers. Additionally, the livers were blindly scored by one observer during two separate assessments longer than 3 months apart.

Results

The criteria macrovesicular steatosis, microvesicular steatosis, hepatocellular hypertrophy, inflammation and fibrosis were generally applicable to rodent NAFLD. The inter-observer reproducibility (evaluated using the Intraclass Correlation Coefficient) between the ten observers was high for the analysis of macrovesicular steatosis and microvesicular steatosis (ICC = 0.784 and 0.776, all p<0.001, respectively) and moderate for the analysis of hypertrophy and inflammation (ICC = 0.685 and 0.650, all p<0.001, respectively). The intra-observer reproducibility between the different observations of one observer was high for the analysis of macrovesicular steatosis, microvesicular steatosis and hypertrophy (ICC = 0.871, 0.871 and 0.896, all p<0.001, respectively) and very high for the analysis of inflammation (ICC = 0.931, p<0.001).

Conclusions

We established a simple NAFLD scoring system with high reproducibility that is applicable for different rodent models and for all stages of NAFLD etiology.  相似文献   

7.

Purpose

To assess the measurement variability of subsolid nodules (SSNs) in follow-up situations and to compare the degree of variability between measurement metrics.

Methods

Two same-day repeat-CT scans of 69 patients (24 men and 45 women) with 69 SSNs were randomly assigned as initial or follow-up scans and were read by the same (situation 1) or different readers (situation 2). SSN size and solid portion size were measured in both situations. Measurement variability was calculated and coefficients of variation were used for comparisons.

Results

Measurement variability for the longest and average diameter of SSNs was ±1.3 mm (±13.0%) and ±1.3 mm (±14.4%) in situation 1, and ±2.2 mm (±21.0%) and ±2.1 mm (±21.3%) in situation 2, respectively. For solid portion, measurement variability on lung and mediastinal windows was ±1.2 mm (±27.1%) and ±0.8 mm (±24.0%) in situation 1, and ±3.7 mm (±61.0%) and ±1.5 mm (±47.3%) in situation 2, respectively. There were no significant differences in the degree of variability between the longest and average diameters and between the lung and mediastinal window settings (p>0.05). However, measurement variability significantly increased when the follow-up and initial CT readers were different (p<0.001).

Conclusions

A cutoff of ±2.2 mm can be reliably used to determine true nodule growth on follow-up CT. Solid portion measurements were not reliable in evaluating SSNs’ change when readers of initial and follow-up CT were different.  相似文献   

8.

Background

Thyroid Imaging Reporting and Data System (TIRADS) was developed to improve patient management and cost-effectiveness by avoiding unnecessary fine needle aspiration biopsy (FNAB) in patients with thyroid nodules. However, its clinical use is still very limited. Strain elastography (SE) enables the determination of tissue elasticity and has shown promising results for the differentiation of thyroid nodules.

Methods

The aim of the present study was to evaluate the interobserver agreement (IA) of TIRADS developed by Horvath et al. and SE. Three blinded observers independently scored stored images of TIRADS and SE in 114 thyroid nodules (114 patients). Cytology and/or histology was available for all benign (n = 99) and histology for all malignant nodules (n = 15).

Results

The IA between the 3 observers was only fair for TIRADS categories 2–5 (Coheńs kappa = 0.27,p = 0.000001) and TIRADS categories 2/3 versus 4/5 (ck = 0.25,p = 0.0020). The IA was substantial for SE scores 1–4 (ck = 0.66,p<0.000001) and very good for SE scores 1/2 versus 3/4 (ck = 0.81,p<0.000001). 92–100% of patients with TIRADS-2 had benign lesions, while 28–42% with TIRADS-5 had malignant cytology/histology. The negative-predictive-value (NPV) was 92–100% for TIRADS using TIRADS-categories 4&5 and 96–98% for SE using score ES-3&4 for the diagnosis of malignancy, respectively. However, only 11–42% of nodules were in TIRADS-categories 2&3, as compared to 58–60% with ES-1&2.

Conclusions

IA of TIRADS developed by Horvath et al. is only fair. TIRADS and SE have high NPV for excluding malignancy in the diagnostic work-up of thyroid nodules.  相似文献   

9.

Purpose

To develop EdgeSelect, a semi-automatic method for the segmentation of retinal layers in spectral domain optical coherence tomography images, and to compare the segmentation results with a manual method.

Methods

SD-OCT (Heidelberg Spectralis) scans of 28 eyes (24 patients with diabetic macular edema and 4 normal subjects) were imported into a customized MATLAB application, and were manually segmented by three graders at the layers corresponding to the inner limiting membrane (ILM), the inner segment/ellipsoid interface (ISe), the retinal/retinal pigment epithelium interface (RPE), and the Bruch''s membrane (BM). The scans were then segmented independently by the same graders using EdgeSelect, a semi-automated method allowing the graders to guide/correct the layer segmentation interactively. The inter-grader reproducibility and agreement in locating the layer positions between the manual and EdgeSelect methods were assessed and compared using the Wilcoxon signed rank test.

Results

The inter-grader reproducibility using the EdgeSelect method for retinal layers varied from 0.15 to 1.21 µm, smaller than those using the manual method (3.36–6.43 µm). The Wilcoxon test indicated the EdgeSelect method had significantly better reproducibility than the manual method. The agreement between the manual and EdgeSelect methods in locating retinal layers ranged from 0.08 to 1.32 µm. There were small differences between the two methods in locating the ILM (p = 0.012) and BM layers (p<0.001), but these were statistically indistinguishable in locating the ISe (p = 0.896) and RPE layers (p = 0.771).

Conclusions

The EdgeSelect method resulted in better reproducibility and good agreement with a manual method in a set of eyes of normal subjects and with retinal disease, suggesting that this approach is feasible for OCT image analysis in clinical trials.  相似文献   

10.

Introduction

Adipose tissue is responsible for triggering chronic systemic inflammatory response and these changes may be involved in the pathophysiology of preeclampsia.

Objective

To characterize the lipid profile in the placenta and plasma of patients with preeclampsia.

Methodology

Samples were collected from placenta and plasma of 10 pregnant women with preeclampsia and 10 controls. Lipids were extracted using the Bligh–Dyer protocol and were analysed by MALDI TOF-TOF mass spectrometry.

Results

Approximately 200 lipid signals were quantified. The most prevalent lipid present in plasma of patients with preeclampsia was the main class Glycerophosphoserines-GP03 (PS) representing 52.30% of the total lipid composition, followed by the main classes Glycerophosphoethanolamines-GP02 (PEt), Glycerophosphocholines-GP01 (PC) and Flavanoids-PK12 (FLV), with 24.03%, 9.47% and 8.39% respectively. When compared to the control group, plasma samples of patients with preeclampsia showed an increase of PS (p<0.0001), PC (p<0.0001) and FLV (p<0.0001). Placental analysis of patients with preeclampsia, revealed the PS as the most prevalent lipid representing 56.28%, followed by the main class Macrolides/polyketides-PK04 with 32.77%, both with increased levels when compared with patients control group, PS (p<0.0001) and PK04 (p<0.0001).

Conclusion

Lipids found in placenta and plasma from patients with preeclampsia differ from those of pregnant women in the control group. Further studies are needed to clarify if these changes are specific and a cause or consequence of preeclampsia.  相似文献   

11.

Objective

To characterize lymphatic vessel morphology in lower extremity lymphedema using MR lymphography at 3T.

Study Design

Forty females with lower extremity lymphedema secondary to gynecologic carcinoma treatment underwent MR lymphography (MRL) at 3T. Lymphatic vessel morphology in normal and affected limbs was compared.

Results

The median diameter of the lymphatic vessels in swollen calf and thigh were significantly larger than that in the contralateral calf and thigh, respectively (p<0.05). The median number of lymphatic vessels visualized in normal calf was less than that in the lymphedematous calf (p<0.01), while no significant difference was found between the normal thigh and swollen thigh. Lymphatic vessel number in the affected calf was significantly greater than that in affected thigh and the mean diameter of affected calf was also significantly wider than that of affected thigh (p<0.01). Mean diameter of lymphatic vessels in the affected calf was significantly different between stage I and stage III (p<0.05), but not significantly different between stages I and II, and between stages II and III (p>0.05). The median number of lymphatic vessels for affected calf showed significant difference between stage I and stage III, and between stage II and stage III (p<0.05), but no significant difference between stage I and stage II (p>0.05). There was no significant difference in mean diameter or median number of lymphatic vessels in the affected thigh found between different stages (p>0.05).

Conclusion

There are significant differences in the number or diameter of lymphatic vessels between normal and affected limbs and there are significant differences for affected calf between early and late stages of lymphedema; therefore, MR lymphography can be helpful in diagnosis or clinical staging for lower extremity with gynecologic oncology-related lymphedema.  相似文献   

12.

Background

The association of right ventricular (RV) structure and function with symptoms in individuals without cardiopulmonary disease is unknown. We hypothesized that greater RV mass and RV end-diastolic volume (RVEDV), smaller RV stroke volume (RVSV), and lower RV ejection fraction (RVEF) measured by cardiac magnetic resonance imaging (MRI) in participants free of clinical cardiovascular disease at baseline would be associated with a greater risk of self-reported dyspnea.

Methods

The Multi-Ethnic Study of Atherosclerosis (MESA) performed cardiac MRIs on participants without clinical cardiovascular disease between 2000 and 2002. We excluded subjects who reported “prevalent” dyspnea at the first assessment (24 months). The presence of dyspnea was assessed at 24 months, 42 months, and 60 months from baseline. Cox proportional hazards models were used to examine the relationship between RV measures and incident dyspnea.

Results

In the final study sample (N = 2763), there were significant interactions between RV measures and sex in terms of the risk of dyspnea (p<0.05). Among men (N = 1453), lower RV mass (p = 0.003), smaller RVEDV (p<0.001), smaller RV end-systolic volume (RVESV) (p = 0.03) and decreased RVSV (p<0.001) were associated with an increased risk of developing dyspnea after adjusting for covariates. Associations remained after adjusting for left ventricular function and lung function. However, there were no significant associations between RV measures and the risk of dyspnea in women.

Conclusions

Lower RV mass and smaller RV volumes were associated with an increased risk of dyspnea in men, but not in women.  相似文献   

13.

Objectives

We sought to determine the feasibility and reproducibility of real-time 3-dimensional echocardiography (RT3DE) for evaluation of cardiac volume, mass, and function and to characterize maturational changes of these measurements in human fetuses.

Methods

Eighty pregnant women in the 2nd and 3rd trimesters (59 with normal fetuses and 21 with fetuses with congenital heart disease [CHD]) were enrolled. We acquired RT3DE images using a matrix-array transducer. RT3DE measurements of volume, mass, stroke volume (SV), combined cardiac output (CCO), and ejection fraction (EF) were obtained. Images were scored and analyzed by two blinded independent observers. Inter- and intraobserver variabilities and correlations between fetal cardiac indices and gestational age were determined.

Results

Fifty-two of 59 normal data sets (88%) and 9 of 21 CHD data sets (43%) were feasible for analysis. In normal fetuses, the right ventricle (RV) is larger than the left ventricle (LV) (P<0.05), but no difference exists between the LV and RV in mass, SV, CO, and CO/CCO. The EFs for the LV and RV were diminished; the RVSV/LVSV was reduced in CHD fetuses compared with normal fetuses (P<0.05). Fetal ventricular volumes, mass, SV, and CCO fit best into exponential curves with gestational age, but LVEF, RVEF, and RVSV/LVSV remain relatively constant.

Conclusions

RT3DE is feasible and reproducible for assessment of LV and RV volume, mass, and function, especially in normal fetuses. Gestational growth of these measures, except for EF, is exponential in normal and CHD fetuses. CHD fetuses exhibit diminished LV and RV EFs.  相似文献   

14.

Objective

To develop abdominal magnetic resonance imaging (MRI) protocol to measure pancreatic volume in humans and to validate it in large animals.

Materials and Methods

We performed abdominal MRI in eight mini-pigs using a clinical 3T MRI system. We used consecutive parallel abdominal slices, covering the entire pancreas to calculate pancreatic volume. Following MRI, animals were sacrificed, the pancreas was removed, and the volume of the pancreas was measured by water displacement. We used the same MRI protocol to measure pancreatic volume in 21 humans. To assess reproducibility of in vivo measurement we repeated MRI pancreas volume evaluation within 24 hours in additional five humans.

Results

In mini-pigs the measurements of pancreatic volume by MRI and by water displacement were almost identical (R2 = 0.9867; p<0.0001). In humans the average pancreas volume was 72.7+/−4.5 ml, range from 35.0 to 105.5 ml. This result is in strong agreement with results of previous large postmortem and computed tomography (CT) studies. Repeated measurements of pancreatic volume in humans were highly reproducible. Pancreatic volume measured in vivo was negatively correlated with age, body fat mass, pancreatic TG levels, and visceral fat mass.

Conclusions

These initial results are highly encouraging and our protocol for pancreatic volume estimation in vivo may prove useful in obesity research to follow in vivo changes of pancreatic volume and structure during time course of obesity and type 2 diabetes development.  相似文献   

15.

Introduction

Mast cells participate in atherogenesis by releasing cytokines to induce vascular cell protease expression. Tryptase is expressed highly in human atherosclerotic lesions and the inhibition of tryptase activity hampers its capacity to maintain cholesterol inside macrophague foam cells. We aimed to investigate the association between circulating tryptase levels and subclinical atherosclerosis through estimation of carotid intima-media thickness (c-IMT) as surrogate marker for increased cardiovascular risk in obese and non-obese subjects.

Methods

Circulating tryptase levels (ELISA) and metabolic parameters were analyzed in 228 subjects. Atherosclerosis (c-IMT>0.9 mm) was evaluated ultrasonographically.

Results

Significant positive associations were evident between circulating tryptase levels and BMI, fat mass, glycated haemoglobin, fasting insulin, HOMAIR, fasting triglycerides and ultrasensitive PCR (p<0.05 from linear-trend ANOVA). The positive association between tryptase levels and insulin resistance parameters, suggested a glucose homeostasis impairment in individuals with higher tryptase levels. The negative asociation between tryptase levels and HDL-cholesterol supports the proatherogenic role of this protease (p<0.0001). Circulating tryptase levels were strongly associated with c-IMT measurements (p<0.0001 from linear-trend ANOVA), and were higher in subjects with presence of carotid plaque (p<0.0001). Tryptase levels (beta = 0.015, p = 0.001) contributed independently to subclinical atherosclerosis variance after controlling for cardiovascular risk factors (BMI, blood pressure, LDL-cholesterol).

Conclusions

Circulating tryptase level is associated to obesity related parameters and has a close relation with various metabolic risk factors. Moreover, serum tryptase level was independently associated with c-IMT, suggesting its potential use as a surrogate marker for subclinical atherosclerosis in obese subjects.  相似文献   

16.

Objective

“Patient-prosthesis mismatch” (PPM) after aortic valve replacement (AVR) has been reported to increase morbidity and mortality. Although algorithms have been developed to avoid PPM, factors favouring its occurrence have not been well defined.

Design and Setting

This was a prospective cohort study performed at the Medical University of Vienna.

Patients

361 consecutive patients who underwent aortic valve replacement for isolated severe aortic stenosis were enrolled.

Main Outcome Measures

Patient- as well as prosthesis-related factors determining the occurrence of moderate and severe PPM (defined as effective orifice area indexed to body surface area ≤ 0.8 cm2/m2) were studied.

Results

Postoperatively, 172 patients (48%) were diagnosed with PPM. The fact that predominantly female patients were affected (58% with PPM diagnosis in women versus 36% in men, p<0.001) was explained by the finding that they had smaller aortic root diameters (30.5±4.7 mm versus 35.3±4.2 mm, p<0.0001) and a higher proportion of bioprosthetic valves (82% versus 62%, p<0.0001), both independent predictors of PPM (aortic root diameter: OR 0.009 [95% CI, 0.004;0.013]; p = 0.0003, presence of bioprosthetic valve: OR 0.126 [95% CI, 0.078;0.175]; p<0.0001).

Conclusions

The occurrence of PPM is determined by aortic root diameter and prosthesis type. Novel sutureless bioprostheses with optimized hemodynamic performance or transcatheter aortic valves may become a promising alternative to conventional bioprosthetic valves in the future.  相似文献   

17.

Objectives

To study the MRI findings of the pancreatic duct in patients with acute pancreatitis.

Materials and Methods

A total of 239 patients with acute pancreatitis and 125 controls were analyzed in this study. The severity of acute pancreatitis was graded using the MR severity index (MRSI) and the Acute Physiology And Chronic Healthy Evaluation II(APACHE II) scoring systems. The number of main pancreatic duct (MPD) segments visualized, and both MPD diameter and pancreatic duct disruption were noted and compared with the severity of acute pancreatitis.

Results

The frequency of MPD segment visualization in the control group was higher than that in the acute pancreatitis group (p<0.05). The number of MPD segments visualized was negatively correlated with the MRSI score (p<0.05) and the APACHE II score (p<0.05). There was no difference in the MPD diameter between the acute pancreatitis and control groups or among the patients with different severities of acute pancreatitis (p>0.05). The prevalence of pancreatic duct disruption was 7.9% in the acute pancreatitis group. The prevalences of pancreatic duct disruption were 4.8% and 15.3% in the mild and severe acute pancreatitis groups based on the APACHE II score, respectively, and were 0%, 5.7% and 43.5% in the mild, moderate and severe acute pancreatitis groups according the MRSI score, respectively. The prevalence of pancreatic duct disruption was correlated with the severity of acute pancreatitis based on the APACHE II score (p<0.05) and MRSI score (p<0.05).

Conclusion

The pancreatic duct in acute pancreatitis patients was of normal diameter. The number of MPD segments visualized and visible pancreatic duct disruption on MRI may be supplementary indicators for determining the severity of acute pancreatitis.  相似文献   

18.

Background

Evaluation and feedback of hand hygiene (HH) compliance are important elements of the WHO multimodal strategy for hospital infection control. Overt observation is recommended, but it may be confounded by Hawthorne effect. Covert observation offers the opportunity to decrease observer bias. In this study we conducted a one year hospital-wide HH promotion program that included medical students (MS) as covert observers.

Methods

HH compliance for the five WHO indications was determined by trained and validated observers. The overt observers consisted of eleven infection control nurses (ICNs) and two unit HH ambassadors (UAs) in each of 83 wards. The covert observers consisted of nine MS during their rotating clinical clerkships. Feedback was provided to department heads and staff each quarter.

Results

Of the 23,333 HH observations 76.0% were by MS, 5.3% by ICNs and 18.7% by UAs. The annual compliance rates were MS 44.1%, ICNs 74.4% and UAs 94.1%; P<0.001. The MS found significantly lower annual compliance rates for 4/5 HH indications compared to ICNs and UAs; P<0.05. The ICNs reported significantly improvement from the first to the fourth quarter; P<0.001. This was associated with feedback from the MS of very poor compliance by nurses during the first quarter.

Conclusions

Based on these findings we recommend a two-pronged approach to HH programs. The role of ICNs and UAs is to educate, serve as role models, establish, sustain good HH practices and provide direct feedback. The role of the covert observers is to measure compliance and provide independent feedback.  相似文献   

19.

Background

The ability of stroke volume variation (SVV), pulse pressure variation (PPV) and global end-diastolic volume (GEDV) for prediction of fluid responsiveness in presence of pleural effusion is unknown. The aim of the present study was to challenge the ability of SVV, PPV and GEDV to predict fluid responsiveness in a porcine model with pleural effusions.

Methods

Pigs were studied at baseline and after fluid loading with 8 ml kg−1 6% hydroxyethyl starch. After withdrawal of 8 ml kg−1 blood and induction of pleural effusion up to 50 ml kg−1 on either side, measurements at baseline and after fluid loading were repeated. Cardiac output, stroke volume, central venous pressure (CVP) and pulmonary occlusion pressure (PAOP) were obtained by pulmonary thermodilution, whereas GEDV was determined by transpulmonary thermodilution. SVV and PPV were monitored continuously by pulse contour analysis.

Results

Pleural effusion was associated with significant changes in lung compliance, peak airway pressure and stroke volume in both responders and non-responders. At baseline, SVV, PPV and GEDV reliably predicted fluid responsiveness (area under the curve 0.85 (p<0.001), 0.88 (p<0.001), 0.77 (p = 0.007). After induction of pleural effusion the ability of SVV, PPV and GEDV to predict fluid responsiveness was well preserved and also PAOP was predictive. Threshold values for SVV and PPV increased in presence of pleural effusion.

Conclusions

In this porcine model, bilateral pleural effusion did not affect the ability of SVV, PPV and GEDV to predict fluid responsiveness.  相似文献   

20.

Background and Purpose

In acute ischemic stroke (AIS) management, CT-based thrombus density has been associated with treatment success. However, currently used thrombus measurements are prone to inter-observer variability and oversimplify the heterogeneous thrombus composition. Our aim was first to introduce an automated method to assess the entire thrombus density and then to compare the measured entire thrombus density with respect to current standard manual measurements.

Materials and Method

In 135 AIS patients, the density distribution of the entire thrombus was determined. Density distributions were described using medians, interquartile ranges (IQR), kurtosis, and skewedness. Differences between the median of entire thrombus measurements and commonly applied manual measurements using 3 regions of interest were determined using linear regression.

Results

Density distributions varied considerably with medians ranging from 20.0 to 62.8 HU and IQRs ranging from 9.3 to 55.8 HU. The average median of the thrombus density distributions (43.5 ± 10.2 HU) was lower than the manual assessment (49.6 ± 8.0 HU) (p<0.05). The difference between manual measurements and median density of entire thrombus decreased with increasing density (r = 0.64; p<0.05), revealing relatively higher manual measurements for low density thrombi such that manual density measurement tend overestimates the real thrombus density.

Conclusions

Automatic measurements of the full thrombus expose a wide variety of thrombi density distribution, which is not grasped with currently used manual measurement. Furthermore, discrimination of low and high density thrombi is improved with the automated method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号