首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Objectives

To evaluate the feasibility of using pseudo-continuous arterial spin labeling (pCASL) perfusion in a geriatric population at 1.5-Tesla.

Materials and Methods

In 17 participants (mean age 78.8±1.63 years) we assessed; 1) inter-session repeatability and reliability of resting state perfusion in 27 brain regions; 2) brain activation using finger-tapping as a means to evaluate the ability to detect flow differences; 3) reliability by comparing cerebral blood flow (CBF) with pCASL to CBF with phase contrast (PC-MR).

Results

The CBF (mean±standard deviation (SD)) for the whole brain grey matter (GM) was 40.6±8.4 and 41.4±8.7 ml/100g/min for the first and second scan respectively. The within-subject standard deviation (SDw), the repeatability index (RI) and intra-class correlation coefficient (ICC) across the 27 regions ranged from 1.1 to 7.9, 2.2 to 15.5 and 0.35 to 0.98 respectively. For whole brain GM the SDw, RI and ICC were 1.6, 3.2 and 0.96 respectively. The between-subject standard deviation (SDB) was larger than the SDw for all regions. Comparison of CBF at rest and activation on a voxel level showed significantly higher perfusion during finger tapping in the motor- and somatosensory regions. The mean CBF for whole brain GM was 40.6±8.4 ml/100g/min at rest and 42.6±8.6 ml/100g/min during activation. Finally the reliability of pCASL against the reference standard of PC-MR was high (ICC = 0.80). The mean CBF for whole brain measured with PC-MRI was 54.3±10.1 ml/100g/min and 38.3±7.8 ml/100g/min with pCASL.

Conclusions

The results demonstrate moderate to high levels of repeatability and reliability for most brain regions, comparable to what has been reported for younger populations. The performance of pCASL at 1.5-Tesla shows that region-specific perfusion measurements with this technique are feasible in studies of a geriatric population.  相似文献   

2.

Purpose

Prior to the implementation of arterial spin labeling (ASL) in clinical multi-center studies, it is important to establish its status quo inter-vendor reproducibility. This study evaluates and compares the intra- and inter-vendor reproducibility of pseudo-continuous ASL (pCASL) as clinically implemented by GE and Philips.

Material and Methods

22 healthy volunteers were scanned twice on both a 3T GE and a 3T Philips scanner. The main difference in implementation between the vendors was the readout module: spiral 3D fast spin echo vs. 2D gradient-echo echo-planar imaging respectively. Mean and variation of cerebral blood flow (CBF) were compared for the total gray matter (GM) and white matter (WM), and on a voxel-level.

Results

Whereas the mean GM CBF of both vendors was almost equal (p = 1.0), the mean WM CBF was significantly different (p<0.01). The inter-vendor GM variation did not differ from the intra-vendor GM variation (p = 0.3 and p = 0.5 for GE and Philips respectively). Spatial inter-vendor CBF and variation differences were observed in several GM regions and in the WM.

Conclusion

These results show that total GM CBF-values can be exchanged between vendors. For the inter-vendor comparison of GM regions or WM, these results encourage further standardization of ASL implementation among vendors.  相似文献   

3.

Objective

The purpose of this study was to determine the accuracy and reliability of Frankfort horizontal plane identification using displays of multi-planar reconstructed MRI images, and propose it as a sufficiently stable and standardized reference plane for craniofacial structures.

Materials and Methods

MRI images of 43 subjects were obtained from the longitudinal population based cohort study SHIP-2 using a T1-weighted 3D sequence. Five examiners independently identified the three landmarks that form FH plane. Intra-examiner reproducibility and inter-examiner reliability, correlation coefficients (ICC), coefficient of variability and Bland-Altman plots were obtained for all landmarks coordinates to assess reproducibility. Intra-examiner reproducibility and inter-examiner reliability in terms of location and plane angulation were also assessed.

Results

Intra- and inter-examiner reliabilities for X, Y and Z coordinates of all three landmarks were excellent with ICC values ranging from 0.914 to 0.998. Differences among examiners were more in X and Z than in Y dimensions. The Bland–Altman analysis demonstrated excellent intra- as well as inter-examiner agreement between examiners in all coordinates for all landmarks. Intra-examiner reproducibility and inter-examiner reliability of the three landmarks in terms of distance showed mean differences between 1.3 to 2.9 mm, Mean differences in plane angulation were between 1.0° to 1.5° among examiners.

Conclusion

This study revealed excellent intra-examiner reproducibility and inter-examiner reliability of Frankfort Horizontal plane through 3D landmark identification in MRI. Sufficiently stable landmark-based reference plane could be used for different treatments and studies.  相似文献   

4.

Purpose

To evaluate the intra- and inter-observer variability of the North American Symptomatic Carotid Endarterectomy Trial (NASCET) and Warfarin-Aspirin Symptomatic Intracranial Disease (WASID) criteria for the evaluation of middle cerebral artery (MCA) stenosis using digital subtraction angiography (DSA).

Materials and Methods

DSA images of 114 cases with 131 stenotic MCAs were retrospectively analyzed. Two radiologists and a researcher measured the degree of MCA stenosis independently using both NASCET and WASID methods. To determine intra-observer agreement, all the observers reevaluated the degree of MCA stenosis 4 weeks later. The linear relation and coefficient of variation (CV) between the measurements made by the two methods were assessed by correlation coefficient and multi-factor analysis of variance (ANOVA), respectively. Intra- and inter-observer variability of the two methods was evaluated by intraclass correlation coefficient (ICC), Spearman’s R value, Pearson correlation coefficient and Bland-Altman plots.

Results

Despite the fact that the degree of MCA stenosis measured by NASCET was lower than measured using the WASID method, there was good linear correlation between the measurements made by the two methods (for the mean measurements of the 3 observers, NASCET% = 0.891 × WASID% - 1.89%; ICC, Spearman’s R value and Pearson correlation were 0.874, 0.855, and 0.874, respectively). The CVs of both intra- and inter-observer measurements of MCA stenosis using WASID were significantly lower than that using NASCET confirmed by the multi-factor ANOVA results, which showed only the measurement methods of MCA stenosis had significant effects on the CVs both in intra- and inter-observer measurements (both P values < 0.001). Intra-observer measurements showed good or excellent agreement with respect to WASID and NASCET evaluation (ICC, 0.656 to 0.817 and 0.635 to 0.761, respectively). Good agreement for the WASID evaluation (ICC, 0.592 to 0.628) and for the NASCET evaluation (ICC, 0.529 to 0.568) was observed for inter-observer measurements. Bland-Altman plots demonstrated that the WASID method had better reproducibility and intra-observer agreement than NASCET method for evaluating MCA stenosis.

Conclusion

Both NASCET and WASID methods have an acceptable level of agreement; however, the WASID method had better reproducibility for the evaluation of MCA stenosis, and thus the WASID method may serve as a standard for measuring the degree of MCA stenosis.  相似文献   

5.

Background

No current validated survey instrument allows a comprehensive assessment of both physical activity and travel behaviours for use in interdisciplinary research on walking and cycling. This study reports on the test-retest reliability and validity of physical activity measures in the transport and physical activity questionnaire (TPAQ).

Methods

The TPAQ assesses time spent in different domains of physical activity and using different modes of transport for five journey purposes. Test-retest reliability of eight physical activity summary variables was assessed using intra-class correlation coefficients (ICC) and Kappa scores for continuous and categorical variables respectively. In a separate study, the validity of three survey-reported physical activity summary variables was assessed by computing Spearman correlation coefficients using accelerometer-derived reference measures. The Bland-Altman technique was used to determine the absolute validity of survey-reported time spent in moderate-to-vigorous physical activity (MVPA).

Results

In the reliability study, ICC for time spent in different domains of physical activity ranged from fair to substantial for walking for transport (ICC = 0.59), cycling for transport (ICC = 0.61), walking for recreation (ICC = 0.48), cycling for recreation (ICC = 0.35), moderate leisure-time physical activity (ICC = 0.47), vigorous leisure-time physical activity (ICC = 0.63), and total physical activity (ICC = 0.56). The proportion of participants estimated to meet physical activity guidelines showed acceptable reliability (k = 0.60). In the validity study, comparison of survey-reported and accelerometer-derived time spent in physical activity showed strong agreement for vigorous physical activity (r = 0.72, p<0.001), fair but non-significant agreement for moderate physical activity (r = 0.24, p = 0.09) and fair agreement for MVPA (r = 0.27, p = 0.05). Bland-Altman analysis showed a mean overestimation of MVPA of 87.6 min/week (p = 0.02) (95% limits of agreement −447.1 to +622.3 min/week).

Conclusion

The TPAQ provides a more comprehensive assessment of physical activity and travel behaviours and may be suitable for wider use. Its physical activity summary measures have comparable reliability and validity to those of similar existing questionnaires.  相似文献   

6.

Purpose

To compare the reproducibilities of manual and semiautomatic segmentation method for the measurement of normalized cerebral blood volume (nCBV) using dynamic susceptibility contrast-enhanced (DSC) perfusion MR imaging in glioblastomas.

Materials and Methods

Twenty-two patients (11 male, 11 female; 27 tumors) with histologically confirmed glioblastoma (WHO grade IV) were examined with conventional MR imaging and DSC imaging at 3T before surgery or biopsy. Then nCBV (means and standard deviations) in each mass was measured using two DSC MR perfusion analysis methods including manual and semiautomatic segmentation method, in which contrast-enhanced (CE)-T1WI and T2WI were used as structural imaging. Intraobserver and interobserver reproducibility were assessed according to each perfusion analysis method or each structural imaging. Interclass correlation coefficient (ICC), Bland-Altman plot, and coefficient of variation (CV) were used to evaluate reproducibility.

Results

Intraobserver reproducibilities on CE-T1WI and T2WI were ICC of 0.74–0.89 and CV of 20.39–36.83% in manual segmentation method, and ICC of 0.95–0.99 and CV of 8.53–16.19% in semiautomatic segmentation method, repectively. Interobserver reproducibilites on CE-T1WI and T2WI were ICC of 0.86–0.94 and CV of 19.67–35.15% in manual segmentation method, and ICC of 0.74–1.0 and CV of 5.48–49.38% in semiautomatic segmentation method, respectively. Bland-Altman plots showed a good correlation with ICC or CV in each method. The semiautomatic segmentation method showed higher intraobserver and interobserver reproducibilities at CE-T1WI-based study than other methods.

Conclusion

The best reproducibility was found using the semiautomatic segmentation method based on CE-T1WI for structural imaging in the measurement of the nCBV of glioblastomas.  相似文献   

7.

Background

To assess the reliability of fetal heart volume measurement by three-dimensional sonography (3DUS) using the eXtended Imaging Virtual Organ Computer-aided AnaLysis (XI VOCAL) method.

Methods

This reliability study enrolled 30 pregnant women with singleton healthy pregnancies between 19 and 34 weeks of gestation. All volume acquirements were performed with a convex volumetric transducer (C3-7ED) coupled to an Accuvix XQ sonography device (Medison, Korea). The XI VOCAL 10 planes was the method of choice for volumetric measurement. 3D datasets were analyzed by two observers (EQSB and HJFM); fetal heart volume was measured twice by the first and once by the second observer to calculate intra and interobserver reproducibility. Statistical analysis used pareated Student's t test (p) and calculated Intraclass correlation coefficients (ICC). Bland-Altman plots were also constructed.

Results

We observed an excellent intra- and interobserver reliability for fetal cardiac volume assessed by XI VOCAL. For the intraobserver the ICC was 0.998 (95% CI: 0.997; 0.999), with mean of differences of 0.12 cm3 (95% limits of agreement: -0.84; +0.84; p = 0.130). For interobserver the ICC was 0.899 (95%CI: 0.996; 0.998), mean of differences 0.05 cm3 (95% limits of agreement: -0.84; +0.84; p = 0.175).

Conclusion

Fetal cardiac volume assessed by 3DUS using XI VOCAL method is highly reproducible between 19 to 34 gestational weeks.  相似文献   

8.

Objectives

Left atrial appendage (LAA) dilatation and morphology may influence an individual''s risk for intracardiac thrombi and ischemic stroke. LAA size and morphology can be evaluated using cardiac computed tomography (cCT). The present study evaluated the reproducibility of LAA volume and morphology assessments.

Methods

A total of 149 patients (47 females; mean age 60.9±10.6 years) with suspected cardioembolic stroke/transient ischemic attack underwent cCT. Image quality was rated based on four categories. Ten patients were selected from each image quality category (N = 40) for volumetric reproducibility analysis by two individual readers. LAA and left atrium (LA) volume were measured in both two-chamber (2CV) and transversal view (TV) orientation. Intertechnique reproducibility was assessed between 2CV and TV (200 measurement pairs). LAA morphology (A = Cactus, B = ChickenWing, C = WindSock, D = CauliFlower), LAA opening height, number of LAA lobes, trabeculation, and orientation of the LAA tip was analysed in all study subjects by three individual readers (447 interobserver measurement pairs). The reproducibility of volume measurements was assessed by intra-class correlation (ICC) and the reproducibility of LAA morphology assessments by Cohen''s kappa.

Results

The intra-observer and interobserver reproducibility of LAA and LA volume measurements was excellent (ICCs>0.9). The LAA (ICC = 0.954) and LA (ICC = 0.945) volume measurements were comparable between 2CV and TV. Morphological classification (ĸ = 0.24) and assessments of LAA opening height (ĸ = 0.1), number of LAA lobes (ĸ = 0.16), trabeculation (ĸ = 0.15), and orientation of the LAA tip (ĸ = 0.37) was only slightly to fairly reproducible.

Conclusions

LA and LAA volume measurements on cCT provide excellent reproducibility, whereas visual assessment of LAA morphological features is challenging and results in unsatisfactory agreement between readers.  相似文献   

9.

Objective

To assess the feasibility of renal proton magnetic resonance spectroscopy for quantification of triglyceride content and to compare spectral quality and reproducibility without and with respiratory motion compensation in vivo.

Materials and Methods

The Institutional Review Board of our institution approved the study protocol, and written informed consent was obtained. After technical optimization, a total of 20 healthy volunteers underwent renal proton magnetic resonance spectroscopy of the renal cortex both without and with respiratory motion compensation and volume tracking. After the first session the subjects were repositioned and the protocol was repeated to assess reproducibility. Spectral quality (linewidth of the water signal) and triglyceride content were quantified. Bland-Altman analyses and a test by Pitman were performed.

Results

Linewidth changed from 11.5±0.4 Hz to 10.7±0.4 Hz (all data pooled, p<0.05), without and with respiratory motion compensation respectively. Mean % triglyceride content in the first and second session without respiratory motion compensation were respectively 0.58±0.12% and 0.51±0.14% (P = NS). Mean % triglyceride content in the first and second session with respiratory motion compensation were respectively 0.44±0.10% and 0.43±0.10% (P = NS between sessions and P = NS compared to measurements with respiratory motion compensation). Bland-Altman analyses showed narrower limits of agreement and a significant difference in the correlated variances (correlation of −0.59, P<0.05).

Conclusion

Metabolic imaging of the human kidney using renal proton magnetic resonance spectroscopy is a feasible tool to assess cortical triglyceride content in humans in vivo and the use of respiratory motion compensation significantly improves spectral quality and reproducibility. Therefore, respiratory motion compensation seems a necessity for metabolic imaging of renal triglyceride content in vivo.  相似文献   

10.

Purpose

To quantify short-term reproducibility (in fasting conditions) and postprandial changes after a meal in portal vein (PV) flow parameters measured with phase contrast (PC) imaging, liver diffusion parameters measured with multiple b value diffusion-weighted imaging (DWI) and liver stiffness (LS) measured with MR elastography (MRE) in healthy volunteers and patients with liver disease at 3.0 T.

Materials and Methods

In this IRB–approved prospective study, 30 subjects (11 healthy volunteers and 19 liver disease patients; 23 males, 7 females; mean age 46.5 y) were enrolled. Imaging included 2D PC imaging, multiple b value DWI and MRE. Subjects were initially scanned twice in fasting state to assess short-term parameter reproducibility, and then scanned 20 min. after a liquid meal. PV flow/velocity, LS, liver true diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (PF) and apparent diffusion coefficient (ADC) were measured in fasting and postprandial conditions. Short-term reproducibility was assessed in fasting conditions by measuring coefficients of variation (CV) and Bland-Altman limits of agreement. Differences in MR metrics before and after caloric intake and between healthy volunteers and liver disease patients were assessed.

Results

PV flow parameters, D, ADC and LS showed good to excellent short-term reproducibility in fasting state (CV <16%), while PF and D* showed acceptable and poor reproducibility (CV = 20.4% and 51.6%, respectively). PV flow parameters and LS were significantly higher (p<0.04) in postprandial state while liver diffusion parameters showed no significant change (p>0.2). LS was significantly higher in liver disease patients compared to healthy volunteers both in fasting and postprandial conditions (p<0.001). Changes in LS were significantly correlated with changes in PV flow (Spearman rho = 0.48, p = 0.013).

Conclusions

Caloric intake had no/minimal/large impact on diffusion/stiffness/portal vein flow, respectively. PC MRI and MRE but not DWI should be performed in controlled fasting state.  相似文献   

11.
Functional Magnetic Resonance Imagine (fMRI) is an important assessment tool in longitudinal studies of mental illness and its treatment. Understanding the psychometric properties of fMRI-based metrics, and the factors that influence them, will be critical for properly interpreting the results of these efforts. The current study examined whether the choice among alternative model specifications affects estimates of test-retest reliability in key emotion processing regions across a 6-month interval. Subjects (N = 46) performed an emotional-faces paradigm during fMRI in which neutral faces dynamically morphed into one of four emotional faces. Median voxelwise intraclass correlation coefficients (mvICCs) were calculated to examine stability over time in regions showing task-related activity as well as in bilateral amygdala. Four modeling choices were evaluated: a default model that used the canonical hemodynamic response function (HRF), a flexible HRF model that included additional basis functions, a modified CompCor (mCompCor) model that added corrections for physiological noise in the global signal, and a final model that combined the flexible HRF and mCompCor models. Model residuals were examined to determine the degree to which each pipeline met modeling assumptions. Results indicated that the choice of modeling approaches impacts both the degree to which model assumptions are met and estimates of test-retest reliability. ICC estimates in the visual cortex increased from poor (mvICC = 0.31) in the default pipeline to fair (mvICC = 0.45) in the full alternative pipeline – an increase of 45%. In nearly all tests, the models with the fewest assumption violations generated the highest ICC estimates. Implications for longitudinal treatment studies that utilize fMRI are discussed.  相似文献   

12.
Previous studies evaluated 3D human jaw movements using kinematic analysis systems during mouth opening, but information on the reliability of such measurements is still scarce. The purpose of this study was to analyze within- and between-session reliabilities, inter-rater reliability, standard error of measurement (SEM), minimum detectable change (MDC) and consistency of agreement across raters and sessions of 3D kinematic variables during maximum mouth opening (MMO). Thirty-six asymptomatic subjects from both genders were evaluated on two different days, five to seven days apart. Subjects performed three MMO movements while kinematic data were collected. Intraclass correlation coefficient (ICC), SEM and MDC were calculated for all variables, and Bland-Altman plots were constructed. Jaw radius and width were the most reproducible variables (ICC > 0.81) and demonstrated minor error. Incisor displacement during MMO and angular movements in the sagittal plane presented good reliability (ICC from 0.61 to 0.8) and small errors and, consequently, could be used in future studies with the same methodology and population. The variables with smaller amplitudes (condylar translations during mouth opening and closing and mandibular movements on the frontal and transversal planes) were less reliable (ICC < 0.61) and presented larger SEM and MDC. Although ICC, SEM and MDC showed less between-session reproducibility than within-session and inter-rater, the limits of agreement were larger in inter-rater comparisons. In future studies care must be taken with variables collected on different days and with mandibular movements in the frontal and transversal planes.  相似文献   

13.
Fundamental to the potential utilisation of heart rate variability (HRV) indices as a prognostic tool is the reproducibility of these measures. The purpose of the present study was therefore to investigate the reproducibility of 24-hour derived HRV indices in a clinical paediatric population. Eighteen children (10 boys; 12.4 ± 2.8 years) with mild to moderate Cystic Fibrosis (CF; FVC: 83 ± 12% predicted; FEV1: 80 ± 9% predicted) and eighteen age- and sex-matched controls (10 boys; 12.5 ± 2.7 years) wore a combined ECG and accelerometer for two consecutive days. Standard time and frequency domain indices of HRV were subsequently derived. Reproducibility was assessed by Bland-Altman plots, 95% limits of agreement and intra-class correlation coefficients (ICC). In both groups, there was no systematic difference between days, with the variables demonstrating a symmetrical, homoscedastic distribution around the zero line. The time domain parameters demonstrated a good to excellent reproducibility irrespective of the population considered (ICC: 0.56 to 0.86). In contrast, whilst the frequency domain parameters similarly showed excellent reproducibility in the healthy children (ICC: 0.70 to 0.96), the majority of the frequency domain parameters illustrated a poor to moderate reproducibility in those with CF (ICC: 0.22 to 0.43). The exceptions to this trend were the normalised LF and HF components which were associated with a good to excellent reproducibility. These findings thereby support the utilisation of time and relative frequency domain HRV indices as a prognostic tool in children with CF. Furthermore, the present results highlight the excellent reproducibility of HRV in healthy children, indicating that this may be a useful tool to assess intervention effectiveness in this population.  相似文献   

14.

Objective

To investigate the reproducibility of diffusion-weighted magnetic resonance imaging (DW-MRI) in assessing tumor response early in the course of neoadjuvant chemoradiotherapy in patients with operable esophageal cancer.

Methods

Eleven male patients (mean age 54.8 years) with newly diagnosed esophageal cancer underwent DW-MRI before and 10 days after start of chemoradiotherapy. Reproducibility of apparent diffusion coefficient (ADC) measurements by manual (freehand) and semi-automated volumetric methods was assessed.

Results

Interobserver reproducibility for the assessment of mean tumor ADC by the manual measurement method was good, with an ICC of 0.69 (95% CI, 0.36 to 0.85; P = 0.001). Interobserver reproducibility for the assessment of mean tumor ADC by the semi-automated volumetric measurement method was very good, with an ICC of 0.96 (95% CI, 0.91 to 0.98; P<0.001).

Conclusion

Semi-automated volumetric ADC measurements have higher reproducibility than manual ADC measurements in assessing tumor response to chemoradiotherapy in patients with esophageal adenocarcinoma.  相似文献   

15.
Yi H  Ji X  Wei X  Chen Z  Wang X  Zhu X  Zhang W  Chen J  Zhang D  Li M 《PloS one》2012,7(1):e30807

Objective

The causes of low back pain in China and Western countries are extremely different. We attempted to analyze the risk factors of low back pain in urban and rural patients under the dual economy with the simplified Chinese version of Roland-Morris disability questionnaire (SC-RMDQ) to demonstrate that SC-RMDQ could evaluate patients with low back pain arising from different causes.

Methods

Roland-Morris disability questionnaire was translated into SCRMDQ according to international guidelines for questionnaire adaptation. In this study, causes of low back pain of 187 outpatients and inpatients (99 urban patients and 88 rural patients) were analyzed. All patients underwent simplified Chinese version of Roland-Morris disability questionnaire (SC-RMDQ), simplified Chinese Oswestry disability index (SCODI) and visual analogue scale (VAS). Reliability was tested using reproducibility (intraclass coefficient of correlation – ICC) and internal consistency (Cronbach''s alpha). Validity was tested using Pearson correlation analysis.

Results

The leading causes for low back pain were sedentariness (38.4%) and vibration (18.1%) in urban patients and waist bending (48.9%) and spraining (25%) in rural patients. Although causes of low back pain in the two groups of population were completely different, SCRMDQ had high internal consistency (Cronbach''s α value of 0.874 in urban patients and 0.883 in rural patients) and good reproducibility (ICC value of .952 in urban patients and 0.949 in rural patients, P<0.01). SCRMDQ also showed significant correlation with Simplified Chinese version of Oswestry disability index (SCODI) and visual analogue scale (VAS) in rural areas (SCRMDQ-SCODI r = 0.841; SCRMDQ -VAS: r = 0.685, P<0.01) and in urban areas (SCRMDQ-SCODI: r = 0.818, P<0.01; SCRMDQ –VAS: r = 0.666, P<0.01).

Conclusions

Although causes of low back pain are completely different in rural and urban patients, SCRMDQ has a good reliability and validity, which is a reliable clinical method to evaluate disability of rural and urban patients.  相似文献   

16.

Purpose

To evaluate a simplified method to measure choroidal thickness (CT) using commercially available enhanced depth imaging (EDI) spectral domain optical coherence tomography (SD-OCT).

Methods

We measured CT in 31 subjects without ocular diseases using Spectralis EDI SD-OCT. The choroid-scleral interface of the acquired images was first enhanced using a post-processing compensation algorithm. The enhanced images were then analysed using Photoshop. Two graders independently graded the images to assess inter-grader reliability. One grader re-graded the images after 2 weeks to determine intra-grader reliability. Statistical analysis was performed using intra-class correlation coefficient (ICC) and Bland-Altman plot analyses.

Results

Using adaptive compensation both the intra-grader reliability (ICC: 0.95 to 0.97) and inter-grader reliability (ICC: 0.93 to 0.97) were perfect for all five locations of CT. However, with the conventional technique of manual CT measurements using built-in callipers provided with the Heidelberg explorer software, the intra- (ICC: 0.87 to 0.94) and inter-grader reliability (ICC: 0.90 to 0.93) for all the measured locations is lower. Using adaptive compensation, the mean differences (95% limits of agreement) for intra- and inter-grader sub-foveal CT measurements were −1.3 (−3.33 to 30.8) µm and −1.2 (−36.6 to 34.2) µm, respectively.

Conclusions

The measurement of CT obtained from EDI SD-OCT using our simplified method was highly reliable and efficient. Our method is an easy and practical approach to improve the quality of choroidal images and the precision of CT measurement.  相似文献   

17.

Background

Radiographic evaluation for patients with scoliosis using Cobb method is the current gold standard, but radiography has radiation hazards. Several groups have recently demonstrated the feasibility of using 3D ultrasound for the evaluation of scoliosis. Ultrasound imaging is radiation-free, comparatively more accessible, and inexpensive. However, a reliable and valid 3D ultrasound system ready for clinical scoliosis assessment has not yet been reported. Scolioscan is a newly developed system targeted for scoliosis assessment in clinics by using coronal images of spine generated by a 3D ultrasound volume projection imaging method. The aim of this study is to test the reliability of spine deformity measurement of Scolioscan and its validity compared to the gold standard Cobb angle measurements from radiography in adolescent idiopathic scoliosis (AIS) patients.

Methods

Prospective study divided into two stages: 1) Investigation of intra- and inter- reliability between two operators for acquiring images using Scolioscan and among three raters for measuring spinal curves from those images; 2) Correlation between the Cobb angle obtained from radiography by a medical doctor and the spine curve angle obtained using Scolioscan (Scolioscan angle). The raters for ultrasound images and the doctors for evaluating radiographic images were mutually blinded. The two stages of tests involved 20 (80 % females, total of 26 angles, age of 16.4?±?2.7 years, and Cobb angle of 27.6?±?11.8°) and 49 (69 % female, 73 angles, 15.8?±?2.7 years and 24.8?±?9.7°) AIS patients, respectively. Intra-class correlation coefficients (ICC) and Bland-Altman plots and root-mean-square differences (RMS) were employed to determine correlations, which interpreted based on defined criteria.

Results

We demonstrated a very good intra-rater and intra-operator reliability for Scolioscan angle measurement with ICC larger than 0.94 and 0.88, respectively. Very good inter-rater and inter-operator reliability was also demonstrated, with both ICC larger than 0.87. For the thoracic deformity measurement, the RMS were 2.5 and 3.3° in the intra- and inter-operator tests, and 1.5 and 3.6° in the intra- and inter-rater tests, respectively. The RMS differences were 3.1, 3.1, 1.6, 3.7° in the intra- and inter-operator and intra- and inter-rater tests, respectively, for the lumbar angle measurement. Moderate to strong correlations (R2?>?0.72) were observed between the Scolioscan angles and Cobb angles for both the thoracic and lumbar regions. It was noted that the Scolioscan angle slightly underestimated the spinal deformity in comparison with Cobb angle, and an overall regression equation y?=?1.1797x (R2?=?0.76) could be used to translate the Scolioscan angle (x) to Cobb angle (y) for this group of patients. The RMS difference between Scolioscan angle and Cobb angle was 4.7 and 6.2°, with and without the correlation using the overall regression equation.

Conclusions

We showed that Scolioscan is reliable for measuring coronal deformity for patients with AIS and appears promising in screening large numbers of patients, for progress monitoring, and evaluation of treatment outcomes. Due to it being radiation-free and relatively low-cost, Scolioscan has potential to be widely implemented and may contribute to reducing radiation dose during serial monitoring.
  相似文献   

18.
IntroductionThe reproducibility of the 3-dimensional (3D) kinematic aspects of motion coupling patterns of segmental manual mobilizing techniques is not yet known. This study analyzes the segmental 3D aspects of manual mobilization of the atlanto-axial joint in vitro.Methods and materialsTwenty fresh human cervical specimens were studied in a test–retest situation with two examiners. The specimens were manually mobilized using three different techniques: a regional mobilization technique, a segmental mobilization technique on the atlas with manual fixation of the axis and a segmental mobilization applying a locking technique. Segmental kinematics were registered with a Zebris CMS20 ultrasound-based tracking system. The 3D aspects of motion coupling between main axial rotation and coupled lateral bending were analyzed by six parameters: the range of motion the three motion components, the cross-correlation, the ratio and the shift.ResultsThe results indicate stronger intra- than inter-examiner reproducibility. The range of motion of the axial rotation component shows a substantial level of intra- and inter-examiner reproducibility (ICC’s 0.67–0.76). The parameters describing the coupling patterns show only moderate to substantial intra-examiner reproducibility for the more experienced of the two examiners (ICC’s 0.55–0.68). All other correlations were not significant and no differences could be observed between regional versus segmental techniques.ConclusionReproducibility of segmental 3D-aspects of manual mobilization of the atlanto-axial joint in an in vitro situation can differ between examiners. The results of the present study may indicate a possible tendency to higher reproducibility if mobilizations are performed by an examiner with high expertise and experience in applying the specific techniques. Continued investigation including more examiners with different levels of experience and different techniques is necessary to confirm these observations.  相似文献   

19.
20.
A study was designed to investigate the intra and intersession reliability during 1-leg standing recorded from a computerized balance platform. Thirty-nine healthy young men (n = 17, age range: 20-30 years) and women (n = 22, age range: 21-28 years) performed 3 testing sessions, with the second session 30 minutes (intrasession comparison) and the third session 1 week (intersession comparison) after the initial testing session. Within each testing session, participants completed 3 trials of 1-leg standing with their dominant leg. Reliability statistics were calculated using the mean of all 3 trials during each session for 6 balance measures (i.e., total displacements of the center of pressure [CoP], the CoP displacements in mediolateral and anterior-posterior directions, and the CoP speed and CoP area and their SD). Test-retest reliability was examined calculating both, intraclass correlation coefficient (ICC) with 95% confidence interval (95% CI) and Bland-Altman plots. In both sexes and irrespective of balance measure, ICC values were ≥0.75 except for 1 parameter in men. This indicates an excellent intra and intersession reliability. Bland-Altman plots confirmed these findings by showing that only 1 or 2 (4.5-11.8%) of the data points were beyond the 95% CI. Practitioners and clinicians are provided with a posturographic test setup that proved to be reliable. Researchers can use these data to identify the range in which the true value of a subject's score lies and estimate a priori sample sizes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号