首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The deposition patterns of large-particle microbiological aerosols within the respiratory tract are not well characterized. A novel system (the flow-focusing aerosol generator [FFAG]) which enables the generation of large (>10-μm) aerosol particles containing microorganisms under laboratory conditions was characterized to permit determination of deposition profiles within the murine respiratory tract. Unlike other systems for generating large aerosol particles, the FFAG is compatible with microbiological containment and the inhalational challenge of animals. By use of entrapped Escherichia coli cells, Bacillus atrophaeus spores, or FluoSphere beads, the properties of aerosols generated by the FFAG were compared with the properties of aerosols generated using the commonly available Collison nebulizer, which preferentially generates small (1- to 3-μm) aerosol particles. More entrapped particulates (15.9- to 19.2-fold) were incorporated into 9- to 17-μm particles generated by the FFAG than by the Collison nebulizer. The 1- to 3-μm particles generated by the Collison nebulizer were more likely to contain a particulate than those generated by the FFAG. E. coli cells aerosolized using the FFAG survived better than those aerosolized using the Collison nebulizer. Aerosols generated by the Collison nebulizer and the FFAG preferentially deposited in the lungs and nasal passages of the murine respiratory tract, respectively. However, significant deposition of material also occurred in the gastrointestinal tract after inhalation of both the small (89.7%)- and large (61.5%)-particle aerosols. The aerosols generated by the Collison nebulizer and the FFAG differ with respect to mass distribution, distribution of the entrapped particulates, bacterial survival, and deposition within the murine respiratory tract.  相似文献   

2.
The present study had three goals: (i) to evaluate the relative quantities of aerosolized Bacillus atrophaeus spores deposited on the vertical, horizontal top, and horizontal bottom surfaces in a chamber; (ii) to assess the relative recoveries of the aerosolized spores from glass and stainless steel surfaces with a polyester swab and a macrofoam sponge wipe; and (iii) to estimate the relative recovery efficiencies of aerosolized B. atrophaeus spores and Pantoea agglomerans using a foam spatula at several different bacterial loads by aerosol distribution on glass surfaces. The majority of spores were collected from the bottom horizontal surface regardless of which swab type and extraction protocol were used. Swabbing with a macrofoam sponge wipe was more efficient in recovering spores from surfaces contaminated with high bioaerosol concentrations than swabbing with a polyester swab. B. atrophaeus spores and P. agglomerans culturable cells were detected on glass surfaces using foam spatulas when the theoretical surface bacterial loads were 2.88 × 104 CFU and 8.09 × 106 CFU per 100-cm2 area, respectively. The median recovery efficiency from the surfaces using foam spatulas was equal to 9.9% for B. atrophaeus spores when the recovery was calculated relative to the theoretical surface spore load. Using a foam spatula permits reliable sampling of spores on the bioaerosol-exposed surfaces in a wide measuring range. The culturable P. agglomerans cells were recovered with a median efficiency of 0.001%, but staining the swab extracts with fluorescent dyes allowed us to observe that the viable cell numbers were higher by 1.83 log units than culturable organisms. However, additional work is needed to improve the analysis of the foam extracts in order to decrease the limit of detection of Bacillus spores and Gram-negative bacteria on contaminated surfaces.Surface sampling is performed on a frequent basis in all situations where clean environment monitoring is needed, e.g., in health care facilities and in the pharmaceutical industry and food industry. An anthrax bioterrorist event in the fall of 2001 has emphasized the importance of efficient sampling methods for detection of pathogenic microorganisms on surfaces within intentionally contaminated locations (22). Unfortunately, our knowledge on the most effective sampling methodology as well as the level of confidence we may have in the results obtained by wiping, swabbing, and other sample collection strategies is still limited (1). Moreover, in most of the studies performed so far, bacteria and/or spores were collected from test samples or coupons of various materials, inoculated with a suspension of microorganisms that had been placed and spread over the surface, and then dried (14, 15). This may not mimic the true situation of surface contamination by a pathogen that has been intentionally released. Edmonds et al. (12) recently reported lower swabbing efficiencies of different types of swab materials used for sampling glass, polycarbonate, and vinyl surfaces contaminated with dry aerosol-deposited Bacillus atrophaeus spores compared to the surfaces inoculated by spore suspensions. Solid surface contamination from exposure to aerosolized spores fits the real world better than the previous models.Therefore, in our study we decided to generate aerosols of various concentrations of B. atrophaeus spores as well as the vegetative cells of Pantoea agglomerans inside a chamber where the bioaerosol particles were allowed to gravitationally settle on solid surfaces. The aerosolization of P. agglomerans was performed to verify the recovery of Gram-negative bacteria according to the recommendations of Budowle et al. (5). The main goal of our study was to establish the range of detection when bioaerosol-contaminated surfaces were swabbed using a commercially available foam spatula.  相似文献   

3.
Current surface sampling methods for microbial contaminants are designed to sample small areas and utilize culture analysis. The total number of microbes recovered is low because a small area is sampled, making detection of a potential pathogen more difficult. Furthermore, sampling of small areas requires a greater number of samples to be collected, which delays the reporting of results, taxes laboratory resources and staffing, and increases analysis costs. A new biological surface sampling method, the Biological Sampling Kit (BiSKit), designed to sample large areas and to be compatible with testing with a variety of technologies, including PCR and immunoassay, was evaluated and compared to other surface sampling strategies. In experimental room trials, wood laminate and metal surfaces were contaminated by aerosolization of Bacillus atrophaeus spores, a simulant for Bacillus anthracis, into the room, followed by settling of the spores onto the test surfaces. The surfaces were sampled with the BiSKit, a cotton-based swab, and a foam-based swab. Samples were analyzed by culturing, quantitative PCR, and immunological assays. The results showed that the large surface area (1 m2) sampled with the BiSKit resulted in concentrations of B. atrophaeus in samples that were up to 10-fold higher than the concentrations obtained with the other methods tested. A comparison of wet and dry sampling with the BiSKit indicated that dry sampling was more efficient (efficiency, 18.4%) than wet sampling (efficiency, 11.3%). The sensitivities of detection of B. atrophaeus on metal surfaces were 42 ± 5.8 CFU/m2 for wet sampling and 100.5 ± 10.2 CFU/m2 for dry sampling. These results demonstrate that the use of a sampling device capable of sampling larger areas results in higher sensitivity than that obtained with currently available methods and has the advantage of sampling larger areas, thus requiring collection of fewer samples per site.  相似文献   

4.
As a bioaerosol sampling standard, Andersen type impactor is widely used since its invention in 1950s, including the investigation of the anthrax attacks in the United States in 2001. However, its related problems such as impaction and desiccation stress as well as particle bounce have not been solved. Here, we improved its biological collection efficiencies by plating a mineral oil layer (100 µL) onto the agar plate. An Andersen six-stage sampler and a BioStage impactor were tested with mineral-oil-spread agar plates in collecting indoor and outdoor bacterial and fungal aerosols. The effects of sampling times (5, 10 and 20 min) were also studied using the BioStage impactor when sampling environmental bioaerosols as well as aerosolized Bacillus subtilis (G+) and Escherichia coli (G-). In addition, particle bounce reduction by mineral-oil-plate was also investigated using an optical particle counter (OPC). Experimental results revealed that use of mineral-oil-spread agar plate can substantially enhance culturable bioaerosol recoveries by Andersen type impactors (p-values<0.05). The recovery enhancement was shown to depend on bioaerosol size, type, sampling time and environment. In general, more enhancements (extra 20%) were observed for last stage of the Andersen six-stage samplers compared to the BioStage impactor for 10 min sampling. When sampling aerosolized B. subtilis, E. coli and environmental aerosols, the enhancement was shown to increase with increasing sampling time, ranging from 50% increase at 5 min to ∼100% at 20 min. OPC results indicated that use of mineral oil can effectively reduce the particle bounce with an average of 66% for 10 min sampling. Our work suggests that enhancements for fungal aerosols were primarily attributed to the reduced impaction stress, while for bacterial aerosols reduced impaction, desiccation and particle bounce played major roles. The developed technology can readily enhance the agar-based techniques including those high volume portable samplers for bioaerosol monitoring.  相似文献   

5.
Bacteriophages are perceived to be good models for the study of airborne viruses because they are safe to use, some of them display structural features similar to those of human and animal viruses, and they are relatively easy to produce in large quantities. Yet, only a few studies have investigated them as models. It has previously been demonstrated that aerosolization, environmental conditions, and sampling conditions affect viral infectivity, but viral infectivity is virus dependent. Thus, several virus models are likely needed to study their general behavior in aerosols. The aim of this study was to compare the effects of aerosolization and sampling on the infectivity of five tail-less bacteriophages and two pathogenic viruses: MS2 (a single-stranded RNA [ssRNA] phage of the Leviviridae family), Φ6 (a segmented double-stranded RNA [dsRNA] phage of the Cystoviridae family), ΦX174 (a single-stranded DNA [ssDNA] phage of the Microviridae family), PM2 (a double-stranded DNA [dsDNA] phage of the Corticoviridae family), PR772 (a dsDNA phage of the Tectiviridae family), human influenza A virus H1N1 (an ssRNA virus of the Orthomyxoviridae family), and the poultry virus Newcastle disease virus (NDV; an ssRNA virus of the Paramyxoviridae family). Three nebulizers and two nebulization salt buffers (with or without organic fluid) were tested, as were two aerosol sampling devices, a liquid cyclone (SKC BioSampler) and a dry cyclone (National Institute for Occupational Safety and Health two-stage cyclone bioaerosol sampler). The presence of viruses in collected air samples was detected by culture and quantitative PCR (qPCR). Our results showed that these selected five phages behave differently when aerosolized and sampled. RNA phage MS2 and ssDNA phage ΦX174 were the most resistant to aerosolization and sampling. The presence of organic fluid in the nebulization buffer protected phages PR772 and Φ6 throughout the aerosolization and sampling with dry cyclones. In this experimental setup, the behavior of the influenza virus resembled that of phages PR772 and Φ6, while the behavior of NDV was closer to that of phages MS2 and ΦX174. These results provide critical information for the selection of appropriate phage models to mimic the behavior of specific human and animal viruses in aerosols.  相似文献   

6.
DNA manipulation routinely requires competent bacteria that can be made using one of numerous methods. To determine the best methods, we compared four commonly used chemical methods (DMSO, MgCl2–CaCl2, CaCl2 and Hanahan''s methods) on frequently used Escherichia coli (E. coli) strains: DH5α, XL-1 Blue, SCS110, JM109, TOP10 and BL21-(DE3)-PLysS. Hanahan''s method was found to be most effective for DH5α, XL-1 Blue and JM109 strains (P<0.05), whilst the CaCl2 method was best for SCS110, TOP10 and BL21 strains (P<0.05). The use of SOB (super optimal broth) over LB [Luria–Bertani (broth)] growth media was found to enhance the competency of XL-1 Blue (P<0.05), dampened JM109′s competency (P<0.05), and had no effect on the other strains (P>0.05). We found no significant differences between using 45 or 90 s heat shock across all the six strains (P>0.05). Through further optimization by means of concentrating the aliquots, we were able to get further increases in transformation efficiencies. Based on the optimized parameters and methods, these common laboratory E. coli strains attained high levels of TrE (transformation efficiency), thus facilitating the production of highly efficient and cost-effective competent bacteria.  相似文献   

7.
Each summer, the nuisance green alga Cladophora (mostly Cladophora glomerata) amasses along Lake Michigan beaches, creating nearshore anoxia and unsightly, malodorous mats that can attract problem animals and detract from visitor enjoyment. Traditionally, elevated counts of Escherichia coli are presumed to indicate the presence of sewage, mostly derived from nearby point sources. The relationship between fecal indicator bacteria and Cladophora remains essentially unstudied. This investigation describes the local and regional density of Escherichia coli and enterococci in Cladophora mats along beaches in the four states (Wisconsin, Illinois, Indiana, and Michigan) bordering Lake Michigan. Samples of Cladophora strands collected from 10 beaches (n = 41) were assayed for concentrations of E. coli and enterococci during the summer of 2002. Both E. coli and enterococci were ubiquitous (up to 97% occurrence), with overall log mean densities (± standard errors) of 5.3 (± 4.8) and 4.8 (± 4.5) per g (dry weight). E. coli and enterococci were strongly correlated in southern Lake Michigan beaches (P < 0.001, R2 = 0.73, n = 17) but not in northern beaches (P = 0.892, n = 16). Both E. coli and enterococci survived for over 6 months in sun-dried Cladophora mats stored at 4°C; the residual bacteria in the dried alga readily grew upon rehydration. These findings suggest that Cladophora amassing along the beaches of Lake Michigan may be an important environmental source of indicator bacteria and call into question the reliability of E. coli and enterococci as indicators of water quality for freshwater recreational beaches.  相似文献   

8.
Ionizing radiation effectively inactivates Escherichia coli O157:H7, but the efficacy of the process against biofilm cells versus that against free-living planktonic cells is not well documented. The radiation sensitivity of planktonic or biofilm cells was determined for three isolates of E. coli O157:H7 (C9490, ATCC 35150, and ATCC 43894). Biofilms were formed on sterile glass slides incubated at 37°C for either 24 h, 48 h, or 72 h. The biofilm and planktonic cultures were gamma irradiated at doses ranging from 0.0 (control) to 1.5 kGy. The dose of radiation value required to reduce the population by 90% (D10) was calculated for each isolate, culture, and maturity based on viable populations at each radiation dose. For each of the times sampled, the D10 values of isolate 43894 planktonic cells (0.454 to 0.479 kGy) were significantly (P < 0.05) higher than those observed for biofilm cells (0.381 to 0.385 kGy), indicating a significantly increased sensitivity to irradiation for cells in the biofilm habitat. At the 24-h sampling time, isolate C9490 showed a similar pattern, in which the D10 values of planktonic cells (0.653 kGy) were significantly higher than those for biofilm cells (0.479 kGy), while isolate 35150 showed the reverse, with D10 values of planktonic cells (0.396 kGy) significantly lower than those for biofilm cells (0.526 kGy). At the 48-h and 72-h sampling times, there were no differences in radiation sensitivities based on biofilm habitat for C9490 or 35150. Biofilm-associated cells, therefore, show a response to irradiation which can differ from that of planktonic counterparts, depending on the isolate and the culture maturity. Culture maturity had a more significant influence on the irradiation efficacy of planktonic cells but not on biofilm-associated cells of E. coli O157:H7.  相似文献   

9.
To study impaction versus impingement for the collection and recovery of viable airborne microorganisms, three new bioaerosol samplers have been designed and built. They differ from each other by the medium onto which the bioaerosol particles are collected (glass, agar, and liquid) but have the same inlet and collection geometries and the same sampling flow rate. The bioaerosol concentrations recorded by three different collection techniques have been compared with each other: impaction onto a glass slide, impaction onto an agar medium, and impingement into a liquid. It was found that the particle collection efficiency of agar slide impaction depends on the concentration of agar in the collection medium and on the sampling time, when samples are collected on a nonmoving agar slide. Impingement into a liquid showed anomalous behavior with respect to the sampling flow rate. Optimal sampling conditions in which all three new samplers exhibit the same overall sampling efficiency for nonbiological particles have been established. Inlet and collection efficiencies of about 100% have been achieved for all three devices at a sampling flow rate of 10 liters/min. The new agar slide impactor and the new impinger were then used to study the biological factors affecting the overall sampling efficiency. Laboratory experiments on the total recovery of a typical environmental microorganism, Pseudomonas fluorescens ATCC 13525, showed that both sampling methods, impaction and impingement, provided essentially the same total recovery when relatively nonstressed microorganisms were sampled under optimal sampling conditions. Comparison tests of the newly developed bioaerosol samplers with those commercially available showed that the incorporation of our research findings into the design of the new samplers yields better performance data than data from currently available samplers.  相似文献   

10.
As a fundamental characteristic of soil physical properties, the soil Particle Size Distribution (PSD) is important in the research on soil moisture migration, solution transformation, and soil erosion. In this research, the PSD characteristics with distinct methods in different land uses are analyzed. The results show that the upper bound of the volume domain of the clay domain ranges from 5.743μm to 5.749μm for all land-use types. For the silt domain of purple soil, the value ranges among 286.852~286.966 μm. For all purple soil land-use types, the order of the volume domain fractal dimensions is Dclay<Dsilt<Dsand. However, the values of Dsilt and Dsand in the Pinus massoniana Lamb, Robinia pseudoacacia L and Ipomoea batatas are all higher than the corresponding values in the Citrus reticulate Blanco and Setaria viridis. Moreover, in all the land-use types, all of the parameters in volume domain fractal dimension (Dvi) are higher than the corresponding parameter values from the United States Department of Agriculture (Dvi(U)). The correlation study between the volume domain fractal dimension and the soil properties shows that the intensity of correlation to the soil texture and soil organic matter has the order as: Dsilt>Dsilt(U)>Dsand (U)>Dsand and Dsilt>Dsilt(U)>Dsand>Dsand(U), respectively. As it is compared with all Dvi, the Dsilt has the most significant correlativity to the soil texture and organic matter in different land uses of the typical purple soil watersheds. Therefore, Dsilt will be a potential indictor for evaluating the proportion of fine particles in the PSD, as well as a key measurement in soil quality and productivity studies.  相似文献   

11.
Knowledge about the sensitivity of the test organism is essential for the evaluation of any disinfection method. In this work we show that sensitivity of Escherichia coli MG1655 to three physical stresses (mild heat, UVA light, and sunlight) that are relevant in the disinfection of drinking water with solar radiation is determined by the specific growth rate of the culture. Batch- and chemostat-cultivated cells from cultures with similar specific growth rates showed similar stress sensitivities. Generally, fast-growing cells were more sensitive to the stresses than slow-growing cells. For example, slow-growing chemostat-cultivated cells (D = 0.08 h−1) and stationary-phase bacteria from batch culture that were exposed to mild heat had very similar T90 (time until 90% of the population is inactivated) values (T90, chemostat = 2.66 h; T90, batch = 2.62 h), whereas T90 for cells growing at a μ of 0.9 h−1 was 0.2 h. We present evidence that the stress sensitivity of E. coli is correlated with the intracellular level of the alternative sigma factor RpoS. This is also supported by the fact that E. coli rpoS mutant cells were more stress sensitive than the parent strain by factors of 4.9 (mild heat), 5.3 (UVA light), and 4.1 (sunlight). Furthermore, modeling of inactivation curves with GInaFiT revealed that the shape of inactivation curves changed depending on the specific growth rate. Inactivation curves of cells from fast-growing cultures (μ = 1.0 h−1) that were irradiated with UVA light showed a tailing effect, while for slow-growing cultures (μ = 0.3 h−1), inactivation curves with shoulders were obtained. Our findings emphasize the need for accurate reporting of specific growth rates and detailed culture conditions in disinfection studies to allow comparison of data from different studies and laboratories and sound interpretation of the data obtained.  相似文献   

12.
In addition to its usual native crystalline form (cellulose I), cellulose can exist in a variety of alternative crystalline forms (allomorphs) which differ in their unit cell dimensions, chain packing schemes, and hydrogen bonding relationships. We prepared, by various chemical treatments, four different alternative allomorphs, along with an amorphous (noncrystalline) cellulose which retained its original molecular weight. We then examined the kinetics of degradation of these materials by two species of ruminal bacteria and by inocula from two bovine rumens. Ruminococcus flavefaciens FD-1 and Fibrobacter succinogenes S85 were similar to one another in their relative rates of digestion of the different celluloses, which proceeded in the following order: amorphous > IIII > IVI > IIIII > I > II. Unlike F. succinogenes, R. flavefaciens did not degrade cellulose II, even after an incubation of 3 weeks. Comparisons of the structural features of these allomorphs with their digestion kinetics suggest that degradation is enhanced by skewing of adjacent sheets in the microfibril, but is inhibited by intersheet hydrogen bonding and by antiparallelism in adjacent sheets. Mixed microflora from the bovine rumens showed in vitro digestion rates quite different from one another and from those of both of the two pure bacterial cultures, suggesting that R. flavefaciens and F. succinogenes (purportedly among the most active of the cellulolytic bacteria in the rumen) either behave differently in the ruminal ecosystem from the way they do in pure culture or did not play a major role in cellulose digestion in these ruminal samples.  相似文献   

13.
Analysis of 100 bagged lettuce and spinach samples showed mean total bacterial counts of 7.0 log10 CFU/g and a broad range of <4 to 8.3 log10 CFU/g. Most probable numbers (MPN) of ≥11,000 /g coliforms were found in 55 samples, and generic Escherichia coli bacteria were detected in 16 samples, but no E. coli count exceeded 10 MPN/g.  相似文献   

14.
The prevalence of antimicrobial drug-resistant bacteria is typically highest in younger animals, and prevalence is not necessarily related to recent use of antimicrobial drugs. In dairy cattle, we hypothesize that antimicrobial drug-resistant, neonate-adapted bacteria are responsible for the observed high frequencies of resistant Escherichia coli in calves. To explore this issue, we examined the age distribution of antimicrobial drug-resistant E. coli from Holstein cattle at a local dairy and conducted an experiment to determine if low doses of oxytetracycline affected the prevalence of antimicrobial drug-resistant E. coli. Isolates resistant to tetracycline (>4 μg/ml) were more prevalent in <3-month-old calves (79%) compared with lactating cows (14%). In an experimental trial where calves received diets supplemented with or without oxytetracycline, the prevalence of tetracycline-resistant E. coli was slightly higher for the latter group (P = 0.039), indicating that drug use was not required to maintain a high prevalence of resistant E. coli. The most common resistance pattern among calf E. coli isolates included resistance to streptomycin (>12 μg/ml), sulfadiazine (>512 μg/ml), and tetracycline (>4 μg/ml) (SSuT), and this resistance pattern was most prevalent during the period when calves were on milk diets. To determine if prevalence was a function of differential fitness, we orally inoculated animals with nalidixic acid-resistant strains of SSuT E. coli and susceptible E. coli. Shedding of SSuT E. coli was significantly greater than that of susceptible strains in neonatal calves (P < 0.001), whereas there was no difference in older animals (P = 0.5). These data support the hypothesis that active selection for traits linked to the SSuT phenotype are responsible for maintaining drug-resistant E. coli in this population of dairy calves.  相似文献   

15.
Increased accumulation of macrophages in adipose tissue in obesity is linked to low-grade chronic inflammation, and associated with features of metabolic syndrome. Vitamin D3 may have immunoregulatory effects and reduce adipose tissue inflammation, although the molecular mechanisms remain to be established. This study investigated the effects of vitamin D3 on macrophage-elicited inflammatory responses in cultured human adipocytes, particularly the signalling pathways involved. Macrophage-conditioned (MC) medium (25% with adipocyte maintenance media) markedly inhibited protein expression of the nuclear factor-κB (NFκB) subunit inhibitor κBα (IκBα) (71%, P<0.001) and increased NFκB p65 (1.5-fold, P = 0.026) compared with controls. Treatment with 1,25-dihydroxyvitamin D3 (1,25(OH)2D3) abolished macrophage-induced activation of NFκB signalling by increasing IκBα expression (2.7-fold, P = 0.005) and reducing NFκB p65 phosphorylation (68%; P<0.001). The mitogen-activated protein kinase (MAPK) signalling was activated by MC medium, which was also blunted by 1,25(OH)2D3 with a downregulation of phosphorylated p38 MAPK (32%, P = 0.005) and phosphorylated Erk1/2 (49%, P = 0.001). Furthermore, MC medium (12.5% or 25%) dose-dependently upregulated secretion of key proinflammatory chemokines/cytokines (22-368-fold; all P<0.001) and this was significantly decreased by 1,25(OH)2D3: IL-8 (61% and 31%, P<0.001), MCP-1 (37%, P<0.001 and 36%, P = 0.002), RANTES (78% and 62%, P<0.001) and IL-6 (29%, P<0.001 and 34%, P = 0.019). Monocyte migration-elicited by adipocytes treated with 1,25(OH)2D3 was also reduced (up to 25%, P<0.001). In conclusion, vitamin D3 could be anti-inflammatory in adipose tissue, decreasing macrophage-induced release of chemokines and cytokines by adipocytes and the chemotaxis of monocytes. Our data suggests these effects are mediated by inhibition of the NFκB and MAPK signalling pathways.  相似文献   

16.
Our objective was to evaluate methods for identifying cattle with high concentrations of Escherichia coli O157 in their feces. In two experiments, feces were collected from cattle orally inoculated with nalidixic acid (Nal)-resistant E. coli O157, and direct plating of diluted feces on sorbitol MacConkey agar with cefixime and potassium tellurite (CT-SMAC) containing Nal was considered the gold standard (GS) method. In experiment 1, methods evaluated were preenrichment direct streak, immunomagnetic separation with most probable number (MPN), and postenrichment direct streak with MPN, all using CT-SMAC. The mean concentration of Nal-resistant E. coli O157 in samples (n = 59) by use of the GS was 3.6 log10 CFU/g. The preenrichment streak detected >3.0 log10 CFU/g samples with a 74.4% sensitivity and 68.8% specificity. Postenrichment direct streak-MPN and immunomagnetic separation-MPN concentrations were correlated significantly with GS concentrations (r = 0.53 and r = 0.39, respectively). In experiment 2 (480 samples), pre- and postenrichment direct streaking performed in triplicate and spiral plating on CT-SMAC were evaluated. For preenrichment streaks, sensitivity was 79.7% and specificity was 96.7% for detecting >3.0 log10 CFU/g when the criterion was positive cultures on at least two plates. For spiral plating at that concentration, sensitivity and specificity were 83.9% and 56.3%, respectively. Postenrichment streaking performed relatively poorly. Triplicate preenrichment streaks of 1:10-diluted feces on CT-SMAC may be useful for identifying cattle shedding high concentrations of E. coli O157. Estimates of sensitivity and specificity enable appropriate application of methods and interpretation of results and may enhance applied research, surveillance, and risk assessments.  相似文献   

17.
We compared fecal samples with samples collected with rectoanal mucosa swabs (RAMS) to determine the prevalence of Escherichia coli O157 in feedlot cattle (n = 747). Escherichia coli O157 was detected in 9.5% of samples collected with RAMS and 4.7% of samples tested by fecal culture. Pulsed-field gel electrophoresis analysis of isolates suggested that the strains colonizing the rectoanal junction were the same as those from the feces. Mucosal swab sampling was more sensitive than fecal sampling for determining the prevalence of E.coli O157 in feedlot cattle.  相似文献   

18.
The concentration and prevalence of Escherichia coli O157 in cattle feces at the time of slaughter was studied over a 9-week period from May to July 2002. Fecal samples (n = 589) were collected from the rectums of slaughtered cattle, and the animal-level prevalence rate was estimated to be 7.5% (95% confidence interval [CI], 5.4 to 9.6%) while the group prevalence was 40.4% (95% CI, 27.7 to 53.2%). Of the 44 infected animals detected, 9% were high shedders that contained E. coli O157 at concentrations of >104 CFU g−1. These 9% represented >96% of the total E. coli O157 produced by all animals tested. All isolates possessed the vt2 gene, 39 had the eaeA gene, and a further five had the vt1 gene also. The presence of high-shedding animals at the abattoir increases the potential risk of meat contamination during the slaughtering process and stresses the need for correctly implemented hazard analysis and critical control point procedures.  相似文献   

19.
20.
Single-particle laser desorption/ionization time-of-flight mass spectrometry, in the form of bioaerosol mass spectrometry (BAMS), was evaluated as a rapid detector for individual airborne, micron-sized, Mycobacterium tuberculosis H37Ra particles, comprised of a single cell or a small number of clumped cells. The BAMS mass spectral signatures for aerosolized M. tuberculosis H37Ra particles were found to be distinct from M. smegmatis, Bacillus atrophaeus, and B. cereus particles, using a distinct biomarker. This is the first time a potentially unique biomarker was measured in M. tuberculosis H37Ra on a single-cell level. In addition, M. tuberculosis H37Ra and M. smegmatis were aerosolized into a bioaerosol chamber and were sampled and analyzed using BAMS, an aerodynamic particle sizer, a viable Anderson six-stage sampler, and filter cassette samplers that permitted direct counts of cells. In a background-free environment, BAMS was able to sample and detect M. tuberculosis H37Ra at airborne concentrations of >1 M. tuberculosis H37Ra-containing particles/liter of air in 20 min as determined by direct counts of filter cassette-sampled particles, and concentrations of >40 M. tuberculosis H37Ra CFU/liter of air in 1 min as determined by using viable Andersen six-stage samplers. This is a first step toward the development of a rapid, stand-alone airborne M. tuberculosis particle detector for the direct detection of M. tuberculosis bioaerosols generated by an infectious patient. Additional instrumental development is currently under way to make BAMS useful in realistic environmental and respiratory particle backgrounds expected in tuberculosis diagnostic scenarios.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号