首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Matrix effects (MEs) continue to be an obstacle in the development of the LC-MS/MS method, with phospholipids being the major cause of MEs. Changing the mobile phase has been a common strategy to reduce MEs; however, the underlying mechanism is unclear. "In-source multiple-reaction monitoring" (IS-MRM) for glycerophosphocholines (PCs) has been commonly applied in many bioanalytical methods. "Visualized MEs" is a suitable term to describe the application of IS-MRM to visualize the elution pattern of phospholipids. We selected a real case to discuss the relationship of MEs and phospholipids in different mobile phases by quantitative, qualitative, and visualized MEs in LC-MS/MS bioanalysis. The application of visualized MEs not only predicts the ion-suppression zone but also helps in selecting an appropriate (1) mobile phase, (2) column, (3) needle wash solvent for the residue of analyte and phospholipids, and (4) evaluates the clean-up efficiency of sample preparation. The TRAM-34 LC-MS/MS method, improved by using visualized MEs, was shown to be a precise and accurate analytical method. All data indicated that the use of visualized MEs indeed provided useful information about the LC-MS/MS method development and improvement. In this study, an integrative approach for the qualitative, quantitative, and visualized MEs was used to decipher the complexity of MEs.  相似文献   

2.
Glycerophosphocholines (GPCho's) are known to cause liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) matrix ionization effects during the analysis of biological samples (i.e. blood, plasma). We have developed a convenient new method, which we refer to as "in-source multiple reaction monitoring" (IS-MRM), for detecting GPCho's during LC-MS/MS method development. The approach uses high energy in-source collisionally induced dissociation (CID) to yield trimethylammonium-ethyl phosphate ions (m/z 184), which are formed from mono- and disubstituted GPCho's. The resulting ion is selected by the first quadrupole (Q1), passed through the collision cell (Q2) in the presence of collision gas at low energy to minimize fragmentation, and m/z 184 selected by the third quadrupole. This approach can be combined with standard multiple reaction monitoring (MRM) transitions with little compromise in sensitivity during method development and sample analysis. Hence, this approach was used to probe ionization matrix effects in plasma samples. The resulting information was employed to develop LC-MS/MS analyses for drugs and their metabolites with cycle times less than 5 min.  相似文献   

3.
A novel method for rapid screening of antimicrobial peptides (AMPs) was developed by using immobilized lipid affinity capture (ILAC) coupled with LC-MS. Phospholipid (PL) mixture containing phosphatidyl glycerol (PG): phosphatidyl ethanolamine (PE) (4:1), roughly mimic the PL composition of Gram-positive bacterial membrane, was covalently immobilized on magnetic particles (MPs). PL monolayer immobilized on MPs was used as a matrix for capturing of the membrane-disruptive AMPs. Hominicin, a new AMP against Gram-positive bacteria, was successfully captured by ILAC from the peptide pool of Staphylococcus hominis MBBL 2–9. The hominicin was identified by the comparative analysis of LC-MS 2Dprofiles of peptides captured by bare and PL-immobilized MPs. This is the first report for the development of rapid AMP screening method using lipid-immobilized MPs and LC-MS which will be a promising tool for discovery of various kinds of AMPs.  相似文献   

4.
The enzymatic cleavage products of β-endorphin (β-endorphin1-27 and Gly-Gln) reduce voluntary alcohol consumption in alcohol-preferring (P) rats. Gly-Gln also inhibits the reward-benefiting effects of morphine and nicotine. It would be useful for the investigation of these effects to have an analytical method suitable for Gly-Gln detection and quantitation. Given the now widespread availability of liquid chromatography-tandem mass spectrometry (LC-MS/MS) instruments, the development of an LC-MS/MS-based approach seemed a viable option. An LC-MS/MS method for Gly-Gln quantitation was developed based on derivatization with Marfey's reagent. The Marfey's adduct of Gly-Gln (Mar-Gly-Gln) was chromatographically resolved and readily detected and quantitated by LC-MS/MS. Precursor/product positive ions of 456.2/366.2, 456.2/237.2, and 456.2/147.0 were used for detection and quantitation. This method shows good linearity from 1 to 500 pmol of Mar-Gly-Gln (R2 > 0.99). The assay also demonstrated good accuracy and precision, with an average percentage standard deviation for Gly-Gln over the range of the assay of less than 5%. A combination of multiple reaction monitoring (MRM) fragment ratio normalization and chromatographic peak shifting was used to ensure that the LC-MS/MS peak for Mar-Gly-Gln was free from possible isobar interferences. This assay was then demonstrated for the determination of in vivo Gly-Gln levels in P and Sprague-Dawley rat cortex and nucleus accumbens samples.  相似文献   

5.
MOTIVATION: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a powerful tool in proteomics studies, but when peptide retention information is used for identification purposes, it remains challenging to compare multiple LC-MS/MS runs or to match observed and predicted retention times, because small changes of LC conditions unavoidably lead to variability in retention times. In addition, non-contiguous retention data obtained with different LC-MS instruments or in different laboratories must be aligned to confirm and utilize rapidly accumulating published proteomics data. RESULTS: We have developed a new alignment method for peptide retention times based on linear solvent strength (LSS) theory. We found that log k(0) (logarithm of retention factor for a given organic solvent) in the LSS theory can be utilized as a 'universal' retention index of peptides (RIP) that is independent of LC gradients, and depends solely on the constituents of the mobile phase and the stationary phases. We introduced a machine learning-based scheme to optimize the conversion function of gradient retention times (t(g)) to log k(0). Using the optimized function, t(g) values obtained with different LC-MS systems can be directly compared with each other on the RIP scale. In an examination of Arabidopsis proteomic data, the vast majority of retention time variability was removed, and five datasets obtained with various LC-MS systems were successfully aligned on the RIP scale.  相似文献   

6.
Self-evidently, research in areas supporting "systems biology" such as genomics, proteomics, and metabonomics are critically dependent on the generation of sound analytical data. Metabolic phenotyping using LC-MS-based methods is currently at a relatively early stage of development, and approaches to ensure data quality are still developing. As part of studies on the application of LC-MS in metabonomics, the within-day reproducibility of LC-MS, with both positive and negative electrospray ionization (ESI), has been investigated using a standard "quality control" (QC) sample. The results showed that the first few injections on the system were not representative, and should be discarded, and that reproducibility was critically dependent on signal intensity. On the basis of these findings, an analytical protocol for the metabonomic analysis of human urine has been developed with proposed acceptance criteria based on a step-by-step assessment of the data. Short-term sample stability for human urine was also assessed. Samples were stable for at least 20 h at 4 degrees C in the autosampler while queuing for analysis. Samples stored at either -20 or -80 degrees C for up to 1 month were indistinguishable on subsequent LC-MS analysis. Overall, by careful monitoring of the QC data, it is possible to demonstrate that the "within-day" reproducibility of LC-MS is sufficient to ensure data quality in global metabolic profiling applications.  相似文献   

7.
We describe the creation of a mass spectral library composed of all identifiable spectra derived from the tryptic digest of the NISTmAb IgG1κ. The library is a unique reference spectral collection developed from over six million peptide-spectrum matches acquired by liquid chromatography-mass spectrometry (LC-MS) over a wide range of collision energy. Conventional one-dimensional (1D) LC-MS was used for various digestion conditions and 20- and 24-fraction two-dimensional (2D) LC-MS studies permitted in-depth analyses of single digests. Computer methods were developed for automated analysis of LC-MS isotopic clusters to determine the attributes for all ions detected in the 1D and 2D studies. The library contains a selection of over 12,600 high-quality tandem spectra of more than 3,300 peptide ions identified and validated by accurate mass, differential elution pattern, and expected peptide classes in peptide map experiments. These include a variety of biologically modified peptide spectra involving glycosylated, oxidized, deamidated, glycated, and N/C-terminal modified peptides, as well as artifacts. A complete glycation profile was obtained for the NISTmAb with spectra for 58% and 100% of all possible glycation sites in the heavy and light chains, respectively. The site-specific quantification of methionine oxidation in the protein is described. The utility of this reference library is demonstrated by the analysis of a commercial monoclonal antibody (adalimumab, Humira®), where 691 peptide ion spectra are identifiable in the constant regions, accounting for 60% coverage for both heavy and light chains. The NIST reference library platform may be used as a tool for facile identification of the primary sequence and post-translational modifications, as well as the recognition of LC-MS method-induced artifacts for human and recombinant IgG antibodies. Its development also provides a general method for creating comprehensive peptide libraries of individual proteins.  相似文献   

8.
Protein cleavage-isotope dilution mass spectrometry (PC-IDMS) can be used to quantify proteins, with an isotope-labeled analogue of the peptide fragment used as an internal standard. Here, we investigate use of a standard LC-MS/MS platform for quantifying a model biomarker directly from serum by this technique. We synthesized a peptide (IVGGWECEK) identical to the N-terminal tryptic fragment of PSA but with each glycine containing two 13C atoms and one 15N atom. PSA-free human serum was denatured with urea followed by the introduction of PSA standard and the stable isotope labeled internal standard peptide. The sample was then proteolyzed with trypsin and subjected to quantification using LC-MS/ MS on a triple quadrupole mass spectrometer. A linear least squares calibration curve made from five different concentrations of PSA added to serum and digested (each made in triplicate and randomly injected three times) had a mean slope of 0.973 (SE = 0.023), intercept of -0.003 (SE = 0.022), and R2 of 0.971. Recovery of calibrators ranged from 70 to 85% with a mean run-to-run CV of 13% and a mean within-run CV of 5.7%. PC-IDMS is a promising technique for quantifying proteins covering a broad range of applications from standardizing immunoassays to monitoring post-translational modifications to quantifying newly discovered biomarkers prior to the development and implementation of an immunoassay, just to name a few. Issues surrounding the application of PC-IDMS for the absolute quantification of proteins include selection of a proteolytic fragment for quantification that can be cleaved and isolated reproducibly over a broad dynamic range, stable isotope labeled synthetic peptide standards that give consistent results, and LC-MS/MS methods that provide adequate sensitivity and reproducibility without creating impractical analysis times. The results presented here show that absolute quantification can be performed on the model biomarker PSA introduced into denatured serum when analyzed by LC-MS/MS. However, concerns still exist regarding sensitivity compared to existing immunoassays as well as the reproducibility of PC-IDMS performed in different matrixes.  相似文献   

9.
BACKGROUND: The structural integrity of recombinant proteins is of critical importance to their application as clinical treatments. Recombinant growth hormone preparations have been examined by several methodologies. In this study recombinant human growth hormone (rhGH; Genotropin(R)), expressed in E. coli K12, was structurally analyzed by two-dimensional gel electrophoresis and MALDI-TOF-TOF, LC-MS and LC-MS/ MS sequencing of the resolved peptides. RESULTS: Electrospray LC-MS analysis revealed one major protein with an average molecular mass of 22126.8 Da and some additional minor components. Electrospray LC-MS/MS evaluation of the enzymatically digested Genotropin(R) sample resulted in the identification of amino acid substitutions at the residues M14, M125, and M170; di-methylation of K70 (or exchange to arginine); deamidation of N149, and N152, and oxidation of M140, M125 and M170. Peak area comparison of the modified and parental peptides indicates that these changes were present in ~2% of the recombinant preparation. CONCLUSION: Modifications of the recombinant human growth hormone may lead to structural or conformational changes, modification of antigenicity and development of antibody formation in treated subjects. Amino acid exchanges may be caused by differences between human and E. coli codon usage and/or unknown copy editing mechanisms. While deamidation and oxidation can be assigned to processing events, the mechanism for possible di-methylation of K70 remains unclear.  相似文献   

10.
Docosahexaenoic acid (DHA) is an n-3 polyunsaturated fatty acid that is highly enriched in the brain, and the oxidation products of DHA are present or increased during neurodegenerative disease progression. The characterization of the oxidation products of DHA is critical to understanding the roles that these products play in the development of such diseases. In this study, we developed a sensitive and specific analytical tool for the detection and quantification of twelve major DHA hydroperoxide (HpDoHE) and hydroxide (HDoHE) isomers (isomers at positions 4, 5, 7, 8, 10, 11, 13, 14, 16, 17, 19 and 20) in biological systems. In this study, HpDoHE were synthesized by photooxidation, and the corresponding hydroxides were obtained by reduction with NaBH4. The isolated isomers were characterized by LC-MS/MS, and unique and specific fragment ions were chosen to construct a selected reaction monitoring (SRM) method for the targeted quantitative analysis of each HpDoHE and HDoHE isomer. The detection limits for the LC-MS/MS-SRM assay were 1−670 pg for HpDoHE and 0.5−8.5 pg for HDoHE injected onto a column. Using this method, it was possible to detect the basal levels of HDoHE isomers in both rat plasma and brain samples. Therefore, the developed LC-MS/MS-SRM can be used as an important tool to identify and quantify the hydro(pero)xy derivatives of DHA in biological system and may be helpful for the oxidative lipidomic studies.  相似文献   

11.
【目的】旨在采用iTRAQ标记结合二维液相色谱串联质谱技术对草菇不同生长发育阶段的差异蛋白质组进行研究。【方法】首先将提取的草菇不同生长阶段蛋白样品进行SDS-PAGE分析,其次将经二维液相色谱串联质谱技术获取的串联质谱数据通过MASCOT软件搜库,之后对鉴定蛋白质数据进行了主成分分析(Principal componentanalysis,PCA)、层次聚类(Hierarchy clustering)分析、K-均值(K-means)聚类和GeneOntology(GO)注释分析。【结果】试验结果显示,共计获得2 335个不同肽段,鉴定到1 039个蛋白质,其中1 030个蛋白质具有定量信息。在子实体阶段中显著上调蛋白质64个,下调蛋白质150个。生物信息学分析表明,iTRAQ标记技术结合二维液相色谱串联质谱可对不同生长发育时期的草菇蛋白样品进行有效地分离和鉴定。【结论】这一研究结果为深入研究草菇乃至其他大型担子菌子实体形成和发育的分子机制提供借鉴。  相似文献   

12.
Integrated liquid-chromatography mass-spectrometry (LC-MS) is becoming a widely used approach for quantifying the protein composition of complex samples. The output of the LC-MS system measures the intensity of a peptide with a specific mass-charge ratio and retention time. In the last few years, this technology has been used to compare complex biological samples across multiple conditions. One challenge for comparative proteomic profiling with LC-MS is to match corresponding peptide features from different experiments. In this paper, we propose a new method--Peptide Element Alignment (PETAL) that uses raw spectrum data and detected peak to simultaneously align features from multiple LC-MS experiments. PETAL creates spectrum elements, each of which represents the mass spectrum of a single peptide in a single scan. Peptides detected in different LC-MS data are aligned if they can be represented by the same elements. By considering each peptide separately, PETAL enjoys greater flexibility than time warping methods. While most existing methods process multiple data sets by sequentially aligning each data set to an arbitrarily chosen template data set, PETAL treats all experiments symmetrically and can analyze all experiments simultaneously. We illustrate the performance of PETAL on example data sets.  相似文献   

13.
The use of liquid chromatography – mass spectrometry (LC-MS) for the characterization of proteins can provide a plethora of information related to their structure, including amino acid sequence determination and analysis of posttranslational modifications. The variety of LC-MS based applications has led to the use of LC-MS characterization of therapeutic proteins and monoclonal antibodies as an integral part of the regulatory approval process. However, the improper use of an LC-MS system, related to intrinsic instrument limitations, improper tuning parameters, or poorly optimized methods may result in the production of low quality data. Improper system performance may arise from subtle changes in operating conditions that limit the ability to detect low abundance species. To address this issue, we systematically evaluated LC-MS/MS operating parameters to identify a set of metrics that can be used in a workflow to determine if a system is suitable for its intended purpose. Development of this workflow utilized a bovine serum albumin (BSA) digest standard spiked with synthetic peptides present at 0.1% to 100% of the BSA digest peptide concentration to simulate the detection of low abundance species using a traditional bottom-up workflow and data-dependent MS2 acquisition. BSA sequence coverage, a commonly used indicator for instrument performance did not effectively identify settings that led to limited dynamic range or poorer absolute mass accuracy on 2 separate LC-MS systems. Additional metrics focusing on the detection limit and sensitivity for peptide identification were determined to be necessary to establish system suitability for protein therapeutic characterization by LC-MS.  相似文献   

14.
Comparing a protein's concentrations across two or more treatments is the focus of many proteomics studies. A frequent source of measurements for these comparisons is a mass spectrometry (MS) analysis of a protein's peptide ions separated by liquid chromatography (LC) following its enzymatic digestion. Alas, LC-MS identification and quantification of equimolar peptides can vary significantly due to their unequal digestion, separation, and ionization. This unequal measurability of peptides, the largest source of LC-MS nuisance variation, stymies confident comparison of a protein's concentration across treatments. Our objective is to introduce a mixed-effects statistical model for comparative LC-MS proteomics studies. We describe LC-MS peptide abundance with a linear model featuring pivotal terms that account for unequal peptide LC-MS measurability. We advance fitting this model to an often incomplete LC-MS data set with REstricted Maximum Likelihood (REML) estimation, producing estimates of model goodness-of-fit, treatment effects, standard errors, confidence intervals, and protein relative concentrations. We illustrate the model with an experiment featuring a known dilution series of a filamentous ascomycete fungus Trichoderma reesei protein mixture. For 781 of the 1546 T. reesei proteins with sufficient data coverage, the fitted mixed-effects models capably described the LC-MS measurements. The LC-MS measurability terms effectively accounted for this major source of uncertainty. Ninety percent of the relative concentration estimates were within 0.5-fold of the true relative concentrations. Akin to the common ratio method, this model also produced biased estimates, albeit less biased. Bias decreased significantly, both absolutely and relative to the ratio method, as the number of observed peptides per protein increased. Mixed-effects statistical modeling offers a flexible, well-established methodology for comparative proteomics studies integrating common experimental designs with LC-MS sample processing plans. It favorably accounts for the unequal LC-MS measurability of peptides and produces informative quantitative comparisons of a protein's concentration across treatments with objective measures of uncertainties.  相似文献   

15.
《MABS-AUSTIN》2013,5(6):1104-1117
The use of liquid chromatography – mass spectrometry (LC-MS) for the characterization of proteins can provide a plethora of information related to their structure, including amino acid sequence determination and analysis of posttranslational modifications. The variety of LC-MS based applications has led to the use of LC-MS characterization of therapeutic proteins and monoclonal antibodies as an integral part of the regulatory approval process. However, the improper use of an LC-MS system, related to intrinsic instrument limitations, improper tuning parameters, or poorly optimized methods may result in the production of low quality data. Improper system performance may arise from subtle changes in operating conditions that limit the ability to detect low abundance species. To address this issue, we systematically evaluated LC-MS/MS operating parameters to identify a set of metrics that can be used in a workflow to determine if a system is suitable for its intended purpose. Development of this workflow utilized a bovine serum albumin (BSA) digest standard spiked with synthetic peptides present at 0.1% to 100% of the BSA digest peptide concentration to simulate the detection of low abundance species using a traditional bottom-up workflow and data-dependent MS2 acquisition. BSA sequence coverage, a commonly used indicator for instrument performance did not effectively identify settings that led to limited dynamic range or poorer absolute mass accuracy on 2 separate LC-MS systems. Additional metrics focusing on the detection limit and sensitivity for peptide identification were determined to be necessary to establish system suitability for protein therapeutic characterization by LC-MS.  相似文献   

16.
Virulence of enterotoxicogenic Escherichia coli is mediated by rodlike, rigid, highly hydrophobic proteins designated fimbriae or colonization factors (CFs). More than 20 different colonization factors have been described so far using predominantly immunological and genetic methods. To characterize these hydrophobic proteins by liquid chromatography-mass spectrometry (LC-MS), different methodologies were explored. A novel LC-MS method was developed using hexafluoroisopropanol to maintain the hydrophobic proteins in solution. In addition, these proteins were digested with cyanogen bromide and peptide mapping by LC-MS was established. This technique was particularly useful in identification of closely related CFs. Both LC-MS and peptide mapping methodologies were found to be useful in characterizing highly hydrophobic CFs of E. coli. To search for molecular weights of mature proteins in the National Center for Biotechnology Information (NCBI) database, a new feature was developed and its applicability tested. The identification of a class of pathogenic virulence proteins, either intact or digested, is possible with molecular weight database searching.  相似文献   

17.
Post-translational modifications are used by cells to control the functions of proteins. Phosducin-like protein (PhLP) is a regulator of G-protein signaling that is post-translationally modified via phosphorylation. Phosphorylation of PhLP initiates its degradation by the 26S proteasome in serum-stimulated cells. In this report, we show that PhLP is phosphorylated in serum-stimulated Chinese hamster ovary (CHO) cells. Through the use of tandem mass spectrometry (MS/MS), the specific amino acids phosphorylated can be identified. A PhLP-myc-His construct was purified and phosphorylated by serum-stimulated CHO extract. The resulting protein was digested with trypsin and the peptides were identified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Automated collison-induced dissociation data acquisition was compared with LC-MS/MS of manually chosen parents. In general, LC-MS/MS is superior for parent ions chosen manually, with the notable exception that automated fragmentation employs dynamic collision energy, which can result in higher quality collison-induced dissociation. Using the LC-MS/MS methods, four phosphorylation sites on PhLP were positively identified.  相似文献   

18.

Background  

Liquid chromatography coupled to mass spectrometry (LC-MS) has become a prominent tool for the analysis of complex proteomics and metabolomics samples. In many applications multiple LC-MS measurements need to be compared, e. g. to improve reliability or to combine results from different samples in a statistical comparative analysis. As in all physical experiments, LC-MS data are affected by uncertainties, and variability of retention time is encountered in all data sets. It is therefore necessary to estimate and correct the underlying distortions of the retention time axis to search for corresponding compounds in different samples. To this end, a variety of so-called LC-MS map alignment algorithms have been developed during the last four years. Most of these approaches are well documented, but they are usually evaluated on very specific samples only. So far, no publication has been assessing different alignment algorithms using a standard LC-MS sample along with commonly used quality criteria.  相似文献   

19.
MOTIVATION: Liquid chromatography coupled to mass spectrometry (LC-MS) and combined with tandem mass spectrometry (LC-MS/MS) have become a prominent tool for the analysis of complex proteomic samples. An important step in a typical workflow is the combination of results from multiple LC-MS experiments to improve confidence in the obtained measurements or to compare results from different samples. To do so, a suitable mapping or alignment between the data sets needs to be estimated. The alignment has to correct for variations in mass and elution time which are present in all mass spectrometry experiments. RESULTS: We propose a novel algorithm to align LC-MS samples and to match corresponding ion species across samples. Our algorithm matches landmark signals between two data sets using a geometric technique based on pose clustering. Variations in mass and retention time are corrected by an affine dewarping function estimated from matched landmarks. We use the pairwise dewarping in an algorithm for aligning multiple samples. We show that our pose clustering approach is fast and reliable as compared to previous approaches. It is robust in the presence of noise and able to accurately align samples with only few common ion species. In addition, we can easily handle different kinds of LC-MS data and adopt our algorithm to new mass spectrometry technologies. AVAILABILITY: This algorithm is implemented as part of the OpenMS software library for shotgun proteomics and available under the Lesser GNU Public License (LGPL) at www.openms.de.  相似文献   

20.
High-performance liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) are generally accepted as the preferred techniques for detecting and quantitating analytes of interest in biological matrices on the basis of the rule that one chemical compound yields one LC-peak with reliable retention time (Rt.). However, in the current study, we have found that under the same LC-MS conditions, the Rt. and shape of LC-peaks of bile acids in urine samples from animals fed dissimilar diets differed significantly among each other. To verify this matrix effect, 17 authentic bile acid standards were dissolved in pure methanol or in methanol containing extracts of urine from pigs consuming either breast milk or infant formula and analyzed by LC-MS/MS. The matrix components in urine from piglets fed formula significantly reduced the LC-peak Rt. and areas of bile acids. This is the first characterization of this matrix effect on Rt. in the literature. Moreover, the matrix effect resulted in an unexpected LC behavior: one single compound yielded two LC-peaks, which broke the rule of one LC-peak for one compound. The three bile acid standards which exhibited this unconventional LC behavior were chenodeoxycholic acid, deoxycholic acid, and glycocholic acid. One possible explanation for this effect is that some matrix components may have loosely bonded to analytes, which changed the time analytes were retained on a chromatography column and interfered with the ionization of analytes in the MS ion source to alter the peak area. This study indicates that a comprehensive understanding of matrix effects is needed towards improving the use of HPLC and LC-MS/MS techniques for qualitative and quantitative analyses of analytes in pharmacokinetics, proteomics/metabolomics, drug development, and sports drug testing, especially when LC-MS/MS data are analyzed by automation software where identification of an analyte is based on its exact molecular weight and Rt.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号