首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A new rapid and sensitive high-performance liquid chromatographic method using 0.5 ml of plasma has been developed for the simultaneous determination of retinol (vitamin A), α-tocopherol (vitamin E), 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3. The eluate was monitored with a photodiode-array detector with two fixed wavelengths (267 nm for vitamin D, 292 nm for α-tocopherol and retinol). For all compounds, including internal standards, the method provides extraction recoveries greater than 81%. Detection limits were equal to or lower than 1.5 μg/l for the 4 vitamins. Linearity of standards was excellent (r>0.999 in all cases). Intra-day and inter-day precision were generally acceptable; the intra-day-assay C.V. was 7.7 for all compounds and the inter-day-assay C.V. was <9.2% except for the lower concentrations of 25-hydroxyvitamin D3, 25-hydroxyvitamin D2 and α-tocopherol (10.8, 11.8 and 11.9, respectively). The important properties of the present method are its ease of use, its rapidity, since sample preparation was achieved in 15 min and all the compounds were eluted in less than 15 min, and its small sample volume required (=0.5 ml), which enables it to be used in pediatric practice.  相似文献   

2.
A method for the determination of 25-hydroxyvitamin D3, the major metabolite of vitamin D3 in human plasma, using a non-radioactive internal standard and reversed-phase high-performance liquid chromatography with UV detection (265 nm) has been developed. The method was applied to the determination of the metabolite in plasma from healthy subjects (n=25) and from patients with chronic renal failure (n=12). 25-Hydroxyvitamin D3 3-sulfate, a major conjugated metabolite of 25-hyroxyvitamin D3, was also determined and the correlation between the concentrations of these metabolites was examined. The study showed that almost equal amounts of both compounds were detected in the plasma of healthy subjects, however, in two subjects, the amount of sulfate in the free form was found to be about twice as high as normally detected. In contrast, the free form was predominant in the plasma of patients with chronic renal failure and the sulfate was not detected in four patients.  相似文献   

3.
Circulating 25-hydroxyvitamin D [25(OH)D] is generally considered the means by which we define nutritional vitamin D status. There is much debate, however, with respect to what a healthy minimum level of circulation 25(OH)D should be. Recent data using various biomarkers such as intact parathyroid hormone (PTH), intestinal calcium absorption, and skeletal density measurements suggest this minimum level to be 80 nmol (32 ng/mL). Surprisingly, the relationship between circulating vitamin D3 and its metabolic product—25(OH)D3 has not been studied. We investigated this relationship in two separate populations: the first, individuals from Hawaii who received significant sun exposure; the second, subjects from a lactation study who received up to 6400 IU vitamin D3/day for 6 months.Results (1) the relationship between circulating vitamin D3 and 25(OH)D in both groups was not linear, but appeared saturable and controlled; (2) optimal nutritional vitamin D status appeared to occur when molar ratios of circulating vitamin D3 and 25(OH)D exceeded 0.3; at this point, the Vmax of the 25-hydroxylase appeared to be achieved. This was achieved when circulating 25(OH)D exceeded 100 nmol.We hypothesize that as humans live today, the 25-hydroxylase operates well below its Vmax because of chronic substrate deficiency, namely vitamin D3. When humans are sun (or dietary) replete, the vitamin D endocrine system will function in a fashion as do these other steroid synthetic pathways, not limited by substrate. Thus, the relationship between circulating vitamin D and 25(OH)D may represent what “normal” vitamin D status should be.  相似文献   

4.
Miao F  Lu D  Li Y  Zeng M 《Analytical biochemistry》2006,352(2):176-181
After first being analyzed by HPLC, 4 free carotenoids, 15 astaxanthin monoesters, 12 astaxanthin diesters, and 3 astacin monoesters in Haematococcus pluvialis were identified by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (LC-(APCI)MS). Identification of each compound was based on the characteristic fragment ions of the positive ion mode, negative ion mode, and MS(2). Astaxanthin esters were identified based on the loss of one or two fatty acids. In a positive ion mode, astaxanthin monoesters had characteristic fragment ions at m/z 597 [M+H-fatty acid](+) and m/z 579 and 561 that resulted from a continuous loss of water. The relative intensity of m/z 579 in MS(2) amounted to more than 80% of that of the molecular ion. In astaxanthin diesters, the intensity of m/z 561 occasionally was equal to that of m/z 579, but in general the former, amounting to 50 to 60% or more of the molecular ion, was stronger than the latter, which decreased to 20 to 30% of the molecular ion. In addition, a set of compounds with maximum absorbance at 400 nm, detected by high-performance liquid chromatography-diode array detector (HPLC-DAD), had strong characteristic fragment ions at m/z 871 and 593 in the positive ion mode MS(2). They were presumed to be linolenic acid or an isomer of omega-6-gamma-linolenic acid esters of astacin.  相似文献   

5.
A simplified method for the determination of 25-hydroxy and 1α,25-dihydroxy metabolites of vitamins D2 and D3 in human plasma was developed. Plasma samples were deproteinizated and applied to a Bond Elut C18 OH cartridge to separate 25-hydroxyvitamin D (25-OH-D) and 1α-25-dihydroxyvitamin D [1,25(OH)2D] fractions. The 25-OH-D fraction was purified by a Bond Elut C18 cartridge and 25-OH-D2 and 25-OH-D3 were assayed by HPLC using a Zorbax SIL column. The 1,25(OH)2D fraction obtained above was subsequently applied to HPLC using a Zorbax SIL column to separate 1,25(OH)2D2 and 1,25(OH)2D3 fractions which were determined by a radioreceptor assay (RRA) using calf thymus receptor. The method was applied to nutritional studies.  相似文献   

6.
Circulating 25-hydroxyvitamin D [25(OH)D] is generally considered the means by which we define nutritional vitamin D status. There is much debate, however, with respect to what a healthy minimum level of circulation 25(OH)D should be. Recent data using various biomarkers such as intact parathyroid hormone (PTH), intestinal calcium absorption, and skeletal density measurements suggest this minimum level to be 80 nmol (32 ng/mL). Surprisingly, the relationship between circulating vitamin D3 and its metabolic product—25(OH)D3 has not been studied. We investigated this relationship in two separate populations: the first, individuals from Hawaii who received significant sun exposure; the second, subjects from a lactation study who received up to 6400 IU vitamin D3/day for 6 months.

Results (1) the relationship between circulating vitamin D3 and 25(OH)D in both groups was not linear, but appeared saturable and controlled; (2) optimal nutritional vitamin D status appeared to occur when molar ratios of circulating vitamin D3 and 25(OH)D exceeded 0.3; at this point, the Vmax of the 25-hydroxylase appeared to be achieved. This was achieved when circulating 25(OH)D exceeded 100 nmol.

We hypothesize that as humans live today, the 25-hydroxylase operates well below its Vmax because of chronic substrate deficiency, namely vitamin D3. When humans are sun (or dietary) replete, the vitamin D endocrine system will function in a fashion as do these other steroid synthetic pathways, not limited by substrate. Thus, the relationship between circulating vitamin D and 25(OH)D may represent what “normal” vitamin D status should be.  相似文献   


7.
Hapten derivatives of 25-hydroxyvitamin D3 and 1α,25-dihydroxyvitamin D3 were synthesized using the Wittig–Horner approach. Both haptens bearing a carboxylic group at the side chain that can be linked to a protein for raising antibodies of potential utility for the determination of 25-hydroxyvitamin D3, 1α,25-dihydroxyvitamin D3 and 1α-hydroxylated vitamin D3 analogues.  相似文献   

8.
Rapid resolution liquid chromatography/tandem multi-stage mass spectrometry (RRLC-MS(n)) and rapid resolution liquid chromatography/tandem mass spectrometry (RRLC/MS/MS) methods were developed for the identification and quantification of ergosterol and its metabolites from rat plasma, urine and faeces. Two metabolites (ERG1 and ERG2) were identified by RRLC/MS(n). The concentrations of the ergosterol were determined by RRLC/MS/MS. The separation was performed on an Agilent Zorbax SB-C18 with the mobile phase consisting of methanol and water (containing 0.1% formic acid). The detection was carried out by means of atmospheric pressure chemical ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 7-2000, 6-2000 and 8-7500 ng/mL for plasma, urine and faecal homogenate, respectively. The intra- and inter-day precision values (RSD) were below 10%. The method was applied to the pharmacokinetic properties and elimination pathway of ergosterol in rats.  相似文献   

9.
The free hormone hypothesis has triggered controversies regarding the measurement of free vitamin D metabolites, such as free 25-hydroxyvitamin D (25(OH)D), as a suitable indicator for total vitamin D for clinical use. This issue can be addressed by developing a precise and accurate method for free 25(OH)D measurement. In the present study, a novel assay method for free 25(OH)D3 based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. Sample preparation first involved ultrafiltration to remove vitamin D-binding protein-bound and albumin-bound 25(OH)D, followed by extraction with a column, derivatization, evaporation, dissolution, and injection into the LC-MS/MS system. The coefficient of variation of repeatability and reproducibility obtained were 3.8–4.5% and 4.8–5.9%, respectively. Satisfactory linearity (r=0.999) was obtained up to 80 pg/ml. The lower quantification limit was 0.97 pg/ml and the S/N ratio on the peak of 1.0 pg/ml sample was 24.8 (which is more than the acceptable value of 10). The recovery rate was between 84.5 and 92.4% with a negligible matrix effect (94.5–104.9%). Levels of free 25(OH)D3, but not total 25(OH)D3, in the serum of the patients with chronic kidney disease (CKD) and hepatic cirrhosis (HC) were substantially lower than those in healthy subjects. The correlation coefficient between total and free 25(OH)D3 was 0.738 in all samples, while the linear regression equations were different between the patients with CKD and HC. In conclusion, LC-MS/MS assay for free 25(OH)D3 might be useful to evaluate high-throughput methods, including ELISA.  相似文献   

10.
A simple and rapid quantitative method for 13C-labelled urea ([13C]urea) in human serum was developed by using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (HPLC-APCI-MS). This method is used to establish and normalize the [13C]urea breath test, which is considered as an effective diagnostic method for Helicobacter pylori infection. HPLC-APCI-MS, involving a simple pretreatment process such as diluting serum with water, was shown to be able to discriminate the extrinsic [13C]urea from intrinsic urea present at high concentration in serum. In addition, a 13C nuclear magnetic resonance spectroscopic quantitative method for [13C]urea in human urine is also described. The precision and accuracy of measured concentrations in these two methods were found to be within the acceptable limit. An application of these methods to investigate the pharmacokinetic profile of orally administered [13C]urea in human serum and urine is also presented.  相似文献   

11.
Phthalates are widely used as industrial solvents and plasticizers, with global use exceeding four million tons per year. We improved our previously developed high-performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometric (HPLC-APCI-MS/MS) method to measure urinary phthalate metabolites by increasing the selectivity and the sensitivity by better resolving them from the solvent front, adding three more phthalate metabolites, monomethyl phthalate (mMP), mono-(2-ethyl-5-oxohexyl)phthalate (mEOHP) and mono-(2-ethyl-5-hydroxyhexyl)phthalate (mEHHP); increasing the sample throughput; and reducing the solvent usage. Furthermore, this improved method enabled us to analyze free un-conjugated mono-2-ethylhexyl phthalate (mEHP) by eliminating interferences derived from coelution of the glucuronide-bound, or conjugated form, of the mEHP on measurements of the free mEHP. This method for measuring phthalate metabolites in urine involves solid-phase extraction followed by reversed-phase HPLC-APCI-MS/MS using isotope dilution with (13)C(4) internal standards. We further evaluated the ruggedness and the reliability of the method by comparing measurements made by multiple analysts at different extraction settings on multiple instruments. We observed mMP, monoethyl phthalate (mEP), mono-n-butyl phthalate (mBP), monobenzyl phthalate (mBzP), mEHP, mEHHP and mEOHP in the majority of urine specimens analyzed with DEHP-metabolites mEHHP and mEOHP present in significantly higher amounts than mEHP.  相似文献   

12.
A highly sensitive and selective method has been developed for the simultaneous quantification of 22R- and 22S-epimers of budesonide in human plasma. The drug was isolated from human plasma using C18 solid-phase extraction cartridges and was acetylated with a mixture of 12.5% acetic anhydride and 12.5% triethylamine in acetonitrile to form the 21-acetyl derivatives. Deuterium-labelled budesonide was synthesized and determined to have an isotopic purity > 99%. This was used as the internal standard. Epimers were quantified by automated liquid chromatography-atmospheric pressure chemical ionization mass spectrometry, operating in selected ion mode at m/z 473.2 and m/z 476.2. Linear responses were observed for both epimers over the range 0.25 to 10.0 ng/ml. The average recoveries of 22R- and 22S-epimers of budesonide from human plasma were 87.4% and 87.0%, respectively. The lower limit of quantification for each epimer was 0.25 ng/ml, corresponding to 50.0 pg of analyte on column. Within- and between-day coefficients of variation were 8.6% and 4.0%, respectively.  相似文献   

13.
A quantitative method for measuring testosterone (T) concentrations in rat plasma was developed using ethyl oxime and acetyl ester derivatization and liquid chromatography-atmosphere pressure chemical ionization tandem mass spectrometry (LC-APCI-MS/MS). The method utilizes a solid phase extraction with Varian Bond Elut C18, a derivatization process to form testosterone ethoxime acetate and LC-APCI-MS/MS with a reversed phase LC and a C8 column. This method is capable of detecting testosterone concentrations as low as 0.2 ng/ml in a 0.05 ml sample of rat plasma. This method can be used as a sensitive chromatography-based assay for small sample volumes of rat blood.  相似文献   

14.
This paper reports the development of three new ternary solvent mixtures for the liquid-chromatographic separation of metabolites of vitamin D on microparticulate silica. All solvent systems offer reduced peak tailing and improved resolution of vitamin D compounds, particularly of 24(R),25-(OH)2D3, when compared to the commonly used hexane—isopropanol mixture. The new mixtures can be substituted for hexane—isopropanol systems presently used for preparative liquid-chromatographic steps prior to radioimmunoassay or competitive protein-binding assay of 24,25-(OH)2D and 1,25-(OH)2D in human plasma. Hexane—isopropanol—methanol (87:10:3) mixtures are recommended where the lipid content of samples is high, whereas hexane—ethanol—chloroform (80:10:10) promises to be a useful mixture for differentiating vitamin D3 metabolites from their vitamin D2 analogs. A combination of the two solvent systems permits the separate assay of both 24(R),25-(OH)2D3 and 24(R),25-(OH)2D2 as well as 1,25-(OH)2D3 and 1,25-(OH)2D2.  相似文献   

15.
We report here a validated method for the quantification of a new immunosuppressant drug FTY720, using HPLC-tandem mass spectrometry. Whole blood samples (500 microl) were subjected to liquid-liquid extraction, in the presence of an internal standard (Y-32919). Mass spectrometric detection was by selected reaction monitoring with an atmospheric pressure chemical ionization source in positive ionization mode (FTY720: m/z 308.3-->255.3). The assay was linear from 0.2 to 25 microg/l (r(2)>0.997, n=5). The inter- and intra-day analytical recovery and imprecision for quality control samples (0.5, 7 and 15 microg/l) were 95.8-103.2 and <5.5%, respectively. At the lower limit of quantification (0.2 microg/l) the inter- and intra-day analytical recovery was 99.0-102.8% with imprecision of <7.6% (n=5). The assay had a mean relative recovery of 100.5+/-5.8% (n=15). Extracted samples were stable for 16 h. FTY720 quality control samples were stable at room temperature for 16 h, at 4 degrees C for at least 8 days and when taken through at least three freeze-thaw cycles. In conclusion, the method described displays analytical performance characteristics that are suitable for pharmacokinetic studies in humans.  相似文献   

16.
The current investigation demonstrates the antitumor effects of combined supplementations of vanadium (V) (4.27 µmol/L drinking water ad libitum) and1α, 25-dihydroxy vitamin D3 (Vitamin D3) (0.3 μg/100 μL propylene glycol per os twice a week) on 1, 2 dimethylhydrazine (DMH) (20 mg/kg body weight) induced rat colon carcinogenesis. There was a significant reduction in incidence (70%), multiplicity (P < 0.0001) and volume (P < 0.01) of colon tumors. HPLC-fluorescence assay detected the combinatorial actions of V and Vitamin D3 against DMH-induced colonic O6-methylguanine DNA adducts formation (at four sequential time points; ANOVA, F = 13.56, P < 0.01). Simultaneous inhibition of DNA single strand breaks (P < 0.001) indicates the potency of the combination regimen in limiting the initiation event of colon carcinogenesis. Immunohistochemical analysis revealed that the effect of V and vitamin D3 occurred through suppression of cell proliferation (BrdU-LI: P < 0.001) along with an induction of apoptosis (TUNEL-LI: P < 0.01). The immunoexpression of tumor suppressor p53 and downregulation of antiapoptotic protein BCl-2 in subsequent immunofluorescence assay further provide strong evidence for the combinatorial inhibitory actions of vanadium and vitamin D3 against DMH-induced rat colon carcinogenesis.  相似文献   

17.
In this study, we describe a simple liquid extraction (methanol/choloroform, 1:1, v/v) method for endogenous free cholesterol and administered sterols extracted from cultured Caco-2 cells. To quantify sterol contents in Caco-2 cells, a new HPLC-APCI-MS method was developed. All the sterols were baseline separated using reversed-phase column (C8, 2.1 mm x 150 mm, 3.5 microm) and isocratic conditions (90%, v/v, methanol-water mixture containing 0.2 mM ammonium acetate). The full scan mass spectra of sterols were measured by an ion trap mass spectrometer equipped with an APCI ion source. The intense fragment ions resulting from the loss of water [M+H-H2O]+ (m/z 369, 395, 397 and 399 for cholesterol, stigmasterol, sitosterol, and sitostanol, respectively) were used for determinations. The absolute extraction recovery of sterols from the spiked cell samples were 109.7+/-26.2, 105.7+/-5.1, 109.8+/-5.0 and 99.0+/-7.0% for cholesterol, stigmasterol, sitosterol, and sitostanol, respectively. Furthermore, no significant matrix effect was observed for the sterols in the cell samples. The sample assay was based on the internal standard method using stigmasterol as an internal standard. The method was linear over the concentration ranges of 0.45-9.0 microM (cholesterol) and 0.225-7.2 microM (sitosterol and sitostanol). The within- and between-day precision was less than 7% and accuracy ranged from 93.51 to 101.77%. The lowest limit of quantitation (LLOQ) was 0.225 microM for sitosterol and sitostanol, and 0.45 microM for cholesterol. The accuracy range was 95-106% and precision was lower than 9% for all LLOQ values.  相似文献   

18.
A method is described for the identification of astaxanthin glucoside esters from snow alga Chlamydomonas nivalis by means of liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization (LC-MS/APCI). The method is based on the use of preparative HPLC and subsequent identification of astaxanthin diglucoside diesters by microbore LC-MS/APCI. The combination of these two techniques was used to identify more than 100 molecular species. The astaxanthin diglucoside diester, i.e. (all-E)-[di-(6-O-oleoyl-beta-D-glucopyranosyloxy)]-astaxanthin, was also synthesized to unambiguously confirm its structure.  相似文献   

19.
Vitamin D3 (VD3) is a fat-soluble prohormone in mammals. VD3 is inert and must be activated by hydroxylation at the C-25 and C-1α positions to exert its biological activity. We recently accomplished the bioconversion of VD3 to 25(OH)VD3 with a recombinant strain of Rhodococcus erythropolis and found that the permeability of VD3 into the cytoplasm may be the rate-limiting step of 25(OH)VD3 production (Sallam et al., 2010). When the cells were treated with the lipid II-targeting lantibiotic nisin, the permeability of green chemiluminescent cyclodextrin (GCCD), which is used as a model substrate instead of VD3-partially methylated-β-cyclodextrin (PMCD) complex, was drastically induced. Nisin also induced VD3 hydroxylation, and the rate was correlated with the expression levels of Vdh and its redox partner proteins. In the bioconversion reaction, the stability of the redox partner proteins and the additional NADH-regenerating system are crucial for VD3 hydroxylation. The degradation rate of the [2Fe–2S] cluster of ferredoxin ThcC from R. erythropolis NI86/21 is faster than that of AciB from Acinetobacter sp. OC4. Therefore, the nisin-treated R. erythropolis cells coexpressing Vdh and AciBC (1176.5 μg) exhibited much greater 25(OH)VD3 production than the cells coexpressing Vdh and ThcCD (431.7 μg) after four consecutive 16 h reactions. These results suggest that nisin forms nisin-lipid II pore complexes in the Rhodococcus membrane that increase the accessibility of VD3–PMCD complexes to the inside of the cells. Furthermore, nisin-treated Rhodococcus cells can be utilized for the bioconversion of other fat-soluble chemicals.  相似文献   

20.
The levels of estrogens and/or their metabolites play important roles in carcinogenesis, reproductive function, and sexual development during perinatal and adolescence periods. The main purpose of this report was to investigate the applicability of high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) with electrospray ionization (ESI) and/or atmospheric pressure chemical ionization (APCI) for simultaneous detection of estrone (E1) and its six metabolites. Both positive and negative ionization modes in ESI and APCI were used to evaluate the signal responses of seven target analytes. Among the seven target analytes, five analytes, E1, 16alpha-hydroxyestrone, 2-methoxyestrone, 4-methoxyestrone, and 2-hydroxyestrone-3-methyl, produced signals with the best signal-to-noise (S/N) ratios in positive APCI-MS/MS mode, while the other two analytes, 2-hydroxyestrone and 4-hydroxyestrone, yielded the best S/N ratios in negative ESI-MS/MS mode. Based on the results of the evaluation, HPLC-APCI-MS/MS with switching between positive and negative modes was recommended for simultaneous detection of E1 and its six metabolites. The proposed analytical scheme was successfully applied in the analysis of cell culture medium of Human liver carcinoma cells treated with varying amounts of 2,3,7,8-tetrachlorodibenzo-p-dioxin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号