1.
To assess the effect of laundry procedures on fabric-associated bacteria, a standard method of enumeration is needed. We evaluated six methods for enumeration of Escherichia coli and Staphylococcus aureus seeded (10(2) and 10(5) CFU/100 cm2 of fabric area) onto sterilized hospital sheets and terry . Two methods involved maceration of seeded swatches in broth followed by passage of the broth through a 0.45-micron-pore-size, 47-mm-diameter filter membrane. Three methods involved agitation of seeded swatches in broth with a paint shaker and membrane filtration of the broth to recover eluted bacterial cells, and the final method involved direct enumeration of cells on fabrics by overlaying seeded swatches with agar containing triphenyltetrazolium chloride as an indicator. The most convenient recovery method employed a 90-s agitation followed by serial dilution of broths and membrane filtration. This method provided 44/57% (low seed/high seed) recovery of E. coli from sheets and 133/31% from terry and 34/74% recovery of S. aureus from sheets and 58/57% from terry . Although maceration provided similar recovery of E. coli and S. aureus, it is a less-practical method. The direct enumeration method was ineffective for enumerating gram-positive bacteria. We conclude that either the agitation or maceration method used enumerated the seeded bacteria to within 1 log10 of their expected number and can be used to assess the bactericidal effectiveness of various steps in the laundering process.  相似文献   

2.
AIMS: To use BioBall cultures as a precise reference standard to evaluate methods for enumeration of Escherichia coli and other coliform bacteria in water samples. METHODS AND RESULTS: Eight methods were evaluated including membrane filtration, standard plate count (pour and spread plate methods), defined substrate technology methods (Colilert and Colisure), the most probable number method and the Petrifilm disposable plate method. Escherichia coli and Enterobacter aerogenes BioBall cultures containing 30 organisms each were used. All tests were performed using 10 replicates. The mean recovery of both bacteria varied with the different methods employed. CONCLUSIONS: The best and most consistent results were obtained with Petrifilm and the pour plate method. Other methods either yielded a low recovery or showed significantly high variability between replicates. SIGNIFICANCE AND IMPACT OF THE STUDY: The BioBall is a very suitable quality control tool for evaluating the efficiency of methods for bacterial enumeration in water samples.  相似文献   

3.
The persistence of Staphylococcus aureus (Smith) on wool blanket, wool gabardine, cotton sheeting, cotton knit jersey, cotton terry cloth, and cotton wash-and-wear fabrics was studied. The fabrics were exposed to bacterial populations by three methods: direct contact, aerosol, and a lyophilized mixture of bacteria and dust having a high content of textile fibers. The contaminated fabrics were held in 35 or 78% relative humidities at 25 C. In general, the persistence time of S. aureus populations on fabrics held in 35% relative humidity was substantially longer when the fabrics were contaminated by exposure to aerosolized cultures or to dust containing bacteria than when contaminated by direct contact. In a 78% relative humidity, bacterial populations on the fabrics persisted for substantially shorter periods of time regardless of the mode of contamination or fabric type. Cotton wash-and-wear fabric (treated with a modified triazone resin) was the material on which populations of S. aureus persisted for the shortest time. This organism retained its virulence for Swiss mice after being recovered from wool gabardine swatches held 4 weeks in 35% relative humidity and 6 weeks in 78% relative humidity.  相似文献   

4.
The epidemiology of Campylobacter jejuni indicates that waterborne transmission is important; the organism has been isolated from seawater, fresh water, and estuarine sites. Membrane filtration, with and without use of an enrichment broth, has been the most common method for isolating C. jejuni from water. We evaluated two methods for isolating C. jejuni from water: membrane filtration and gauze filtration. The membrane filters evaluated included 0.22- and 0.45-micron-pore Millipore filters (Millipore Corp., Bedford, Mass.), 0.2- and 0.4-micron-pore Nuclepore filters (Nucleopore Corp., Pleasanton, Calif.), and a 0.45-micron-pore Zetapor filters (AMF Cuno, Meridian, Conn.). The gauze filters included both Moore and Spira swabs. Of the membrane filters evaluated, the 0.45-micron-pore Millipore and Zetapor filters were the most sensitive for recovery of C. jejuni from seeded waters. The 0.45-micron-pore Millipore filter placed in Oosterom broth was better for recovery of C. jejuni from seeded stationary surface waters than either the Spira or Moore swab. However, the 0.45-micron-pore Millipore filter placed on a plate or in enrichment broth was equivalent to the Spira gauze swab when used to examine water from Atlanta area streams. C. jejuni organisms were isolated from 9 of 24 surface water samples representing 5 of 12 streams.  相似文献   

5.
The epidemiology of Campylobacter jejuni indicates that waterborne transmission is important; the organism has been isolated from seawater, fresh water, and estuarine sites. Membrane filtration, with and without use of an enrichment broth, has been the most common method for isolating C. jejuni from water. We evaluated two methods for isolating C. jejuni from water: membrane filtration and gauze filtration. The membrane filters evaluated included 0.22- and 0.45-micron-pore Millipore filters (Millipore Corp., Bedford, Mass.), 0.2- and 0.4-micron-pore Nuclepore filters (Nucleopore Corp., Pleasanton, Calif.), and a 0.45-micron-pore Zetapor filters (AMF Cuno, Meridian, Conn.). The gauze filters included both Moore and Spira swabs. Of the membrane filters evaluated, the 0.45-micron-pore Millipore and Zetapor filters were the most sensitive for recovery of C. jejuni from seeded waters. The 0.45-micron-pore Millipore filter placed in Oosterom broth was better for recovery of C. jejuni from seeded stationary surface waters than either the Spira or Moore swab. However, the 0.45-micron-pore Millipore filter placed on a plate or in enrichment broth was equivalent to the Spira gauze swab when used to examine water from Atlanta area streams. C. jejuni organisms were isolated from 9 of 24 surface water samples representing 5 of 12 streams.  相似文献   

6.
Four membrane filter methods fecal coliform enumeration were evaluated and compared in six laboratories based on determination of accuracy, specificity, upper counting limit, and recovery comparability. Recovery accuracy with pure cultures ranged from 89 to 100% for m-FC, mTEC (a procedure developed for thermotolerant Escherichia coli), and m-FC2 methods (the latter incorporating a 2-h, 35 degrees C resuscitation period), but was less than 60% for the MacConkey membrane broth method. These figures dropped by approximately 40 to 55% when the cultures were subjected to temperature (10 degrees C) stress. Close to 800 colonies were verified to determine specificity. False-positive colonies occurred most frequently with the m-FC2 method (18%), whereas false-negative colonies were most common on MacConkey membrane broth (26%). In counting range experiments using a variety of samples, the highest upper counting limit was 130 colonies per filter with the mTEC procedure. Recovery comparisons were based on over 130 samples including raw surface waters, raw sewage, and chlorinated and unchlorinated sewage effluents. In general, recoveries were significantly higher with the m-FC2 and mTEC methods; however, on m-FC2, growth of nontarget background organisms was also higher in most cases. Highest recoveries from chlorinated sewage effluents were obtained by the mTEC method, and the addition of a similar resuscitation period to the m-FC procedure (m-FC2) improved fecal coliform recovery from such samples. The best overall performance for fecal coliform enumeration was obtained with the mTEC method with high recovery and low levels of background colonies, good specificity and accuracy, and a high upper counting limit. This procedure also offers the advantage of enumerating E. coli within 24 h.  相似文献   

7.
【目的】采用不同实验方法测定常用有机溶剂二甲基亚砜(DMSO)、丙酮和乙醇对细菌活性的影响,以指导抗菌类药物体外抑菌实验所用溶剂的选择和添加限量。【方法】采用常规体外抑菌实验方法(纸片扩散法、肉汤稀释法),并参照生长曲线法检测有机溶剂DMSO、丙酮和乙醇对大肠杆菌(Escherichia coli)及金黄色葡萄球菌(Staphylococcus aureus)的抑菌作用,采用扫描电子显微镜(SEM)观察溶剂作用后的细菌形态变化。【结果】3种溶剂对E.coli和S.aureus抑菌率达到20%时,在肉汤稀释法下,DMSO、丙酮、乙醇的浓度(体积比)分别为1.00%、0.25%、2.00%和1.00%、1.00%、0.50%;在生长曲线法下,溶剂浓度(体积比)分别为0.50%、1.00%、0.50%和1.00%、0.50%、0.50%;而在纸片扩散法下,32%(体积比)DMSO和32%(体积比)乙醇对E.coli产生明显抑菌圈,但3种溶剂对S.aureus均无抑菌圈出现。3种方法比较后得出:当3种溶剂的抑菌率达到20%时,溶剂浓度(体积比)均低于0.5%,对细菌整体生长活性影响较小。SEM结果表明控制溶剂使用限量可有效减少其对E.coli生长过程的影响。【结论】相对于DMSO和丙酮,乙醇对微生物生长繁殖能力的影响更加明显;采用相同浓度有机溶剂时,液态条件下(肉汤稀释法和生长曲线法)微生物受到有机溶剂的影响较大。  相似文献   

8.
AIMS: To compare growth and survival of selected bacteria implicated in sudden infant death syndrome (SIDS) on cot mattress polyurethane (PU) inner-foams and on different types of cot mattress cover materials. METHODS AND RESULTS: Escherichia coli, Staphylococcus aureus or Streptococcus pyogenes were inoculated onto swatches of new-unused cot mattress PU inner-foam and onto three types of cot mattress covers (polyvinyl chloride, cotton and polyester). The influence of inoculation cell density, relative humidity (RH) and temperature of incubation on survival was assessed by recovery of cells in 0.85% NaCl, with viable cell enumeration by plate counting on selective and differential media. Utilization of carbon and nitrogen sources within cot mattress PU was assessed by following growth on aqueous leachate from PU, and by colorimetric determination of aromatic amines. Good survival capability (>206 d) was shown by all three test species on PU inner-foam and on polyester mattress cover at high RH (75%), but only by Staph. aureus on PU at low RH (25%). Aqueous soluble material from PU foam supports bacterial growth; removal of aromatic amines from aqueous leachate from PU accompanies growth of Staph. aureus. CONCLUSIONS: Staphylococcus aureus has good survival capability on cot mattress PU foam, even at low RH. Soluble material within PU can serve as carbon and nitrogen sources for bacterial growth. SIGNIFICANCE AND IMPACT OF THE STUDY: Prolonged survival of Staph. aureus on PU at low RH could explain, in the context of the common bacterial toxins hypothesis, an increased risk of SIDS associated with used infant mattresses.  相似文献   

9.
The aim of this study was to investigate the impact on numbers of using different media for the enumeration of Escherichia coli subjected to stress, and to evaluate the use of different resuscitation methods on bacterial numbers. E. coli was subjected to heat stress by exposure to 55 degrees C for 1h or to light-induced oxidative stress by exposure to artificial light for up to 8h in the presence of methylene blue. In both cases, the bacterial counts on selective media were below the limits of detection whereas on non-selective media colonies were still produced. After resuscitation in non-selective media, using a multi-well MPN resuscitation method or resuscitation on membrane filters, the bacterial counts on selective media matched those on non-selective media. Heat and light stress can affect the ability of E. coli to grow on selective media essential for the enumeration as indicator bacteria. A resuscitation method is essential for the recovery of these stressed bacteria in order to avoid underestimation of indicator bacteria numbers in water. There was no difference in resuscitation efficiency using the membrane filter and multi-well MPN methods. This study emphasises the need to use a resuscitation method if the numbers of indicator bacteria in water samples are not to be underestimated. False-negative results in the analysis of drinking water or natural bathing waters could have profound health effects.  相似文献   

10.
Membrane adsorption-elution techniques have made it possible to concentrate and detect small numbers of viruses in large volumes of water and wastewater, but no such methods are available for quantitative recovery of bacteria. A number of waterborne disease outbreaks of "unknown etiology" in the United States are suspected to have been caused by pathogens present in numbers too small to be detected by currently available methodology. The present study reports on the use of positively charged depth filters for the concentration and detection of bacteria in large volumes of tap water. In this method, dechlorinated tap water was passed, under positive pressure, through positively charged filter media (Zetaplus, 05S). More than 90% of seeded bacteria adsorbed to these filters at ambient pH levels. Adsorbed bacteria were eluted by passing a small volume of Trypticase soy broth in the direction opposite of the influent flow. By this method, Escherichia coli and Salmonella serovar B organisms in 20 liters of tap water were concentrated in a final volume of 50 ml, with an average recovery efficiency of greater than or equal to 30%.  相似文献   

11.
A medium for the single membrane enumeration of Escherichia coli and coliforms from potable water was developed by the modification of the standard UK membrane filtration medium. The medium, membrane-Lactose Glucuronide Agar (m-LGA), employs a chromogenic substrate for the detection of β-glucuronidase activity and sodium pyruvate to enhance recovery of chlorine-stressed coliforms. Escherichia coli identification was significantly improved on m-LGA with 98.6% of presumptive isolates confirming. Recovery of coliforms from drinking water samples was also significantly improved.  相似文献   

12.
A modified adsorption-elution method for the concentration of seeded rotavirus from water samples was used to determine various factors which affected the virus recovery. An enzyme-linked immunosorbent assay was used to detect the rotavirus antigen after concentration. Of the various eluents compared, 0.05M glycine, pH 11.5 gave the highest rotavirus antigen recovery using negatively charged membrane filtration whereas 2.9% tryptose phosphate broth containing 6% glycine; pH 9.0 was found to give the greatest elution efficiency when a positively charged membrane was used. Reconcentration of water samples by a speedVac concentrator showed significantly higher rotavirus recovery than polyethylene glycol precipitation through both negatively and positively charged filters (p-value <0.001). In addition, speedVac concentration using negatively charged filtration resulted in greater rotavirus recovery than that using positively charged filtration (p-value = 0.004). Thirty eight environmental water samples were collected from river, domestic sewage, canals receiving raw sewage drains, and tap water collected in containers for domestic use, all from congested areas of Bangkok. In addition, several samples of commercial drinking water were analyzed. All samples were concentrated and examined for rotavirus antigen. Coliforms and fecal coliforms (0->1,800 MPN/100 ml) were observed but rotavirus was not detected in any sample. This study suggests that the speedVac reconcentration method gives the most efficient rotavirus recovery from water samples.  相似文献   

13.
Recovery of total coliforms and Escherichia coli on a new membrane filtration (MF) medium was evaluated with 25 water samples from seven states. Testing of the new medium, m-ColiBlue24 broth, was conducted according to a U.S. Environmental Protection Agency protocol. For comparison, this same protocol was used to measure recovery of total coliforms and E. coli with two standard MF media, m-Endo broth and mTEC broth. E. coli recovery on the new medium was also compared to recovery on nutrient agar supplemented with 4-methylumbelliferyl-beta-D-glucuronide. Comparison of specificity, sensitivity, false positive error, undetected target error, and overall agreement indicated E. coli recovery on m-ColiBlue24 was superior to recovery on mTEC for all five parameters. Recovery of total coliforms on the new medium was comparable to recovery on m-Endo.  相似文献   

14.
This study compared the performance of LMX(R) broth (LMX), Chromocult Coliform(R) agar (CC) and Chromocult Coliform agar plus cefsulodin (10 microg ml-1) (CC-CFS), with standard methods multiple tube fermentation (MTF), for the enumeration of total coliforms and Escherichia coli from marine recreational waters. LMX and CC are two media designed to concurrently detect total coliform (TC) bacteria and E. coli by the specific action of beta-galactosidase (total coliforms) and beta-glucuronidase (E. coli). Overall results for the TC test showed that LMX, CC and MTF recovered 2.63, 1.95 and 1.90 times as many TCs as CC-CFS, respectively. Data from the multiple range test showed significant differences (P < 0.05) between TC counts on CC-CFS and LMX. The traditional MTF was less sensitive for E. coli enumeration. However, there was no statistically significant differences between LMX, CC, CC-CFS and the MTF method for E. coli enumeration. Background interference was reduced on CC-CFS and the counts obtained reflected more accurately the number of TCs. Therefore, the contribution of beta-galactosidase positive, non coliform bacteria (Aeromonas spp. and Vibrio spp.) to TC counts should not be neglected.  相似文献   

15.
Four membrane filter methods for the enumeration of fecal coliforms were compared for accuracy, specificity, and recovery. Water samples were taken several times from 13 marine, 1 estuarine, and 4 freshwater sites around Puerto Rico, from pristine waters and waters receiving treated and untreated sewage and effluent from a tuna cannery and a rum distillery. Differences of 1 to 3 orders of magnitude in the levels of fecal coliforms were observed in some samples by different recovery techniques. Marine water samples gave poorer results, in terms of specificity, selectivity, and comparability, than freshwater samples for all four fecal coliform methods used. The method using Difco m-FC agar with a resuscitation step gave the best overall results; however, even this method gave higher false-positive error, higher undetected-target error, lower selectivity, and higher recovery of nontarget organisms than the method using MacConkey membrane broth, the worst method for temperate waters. All methods tested were unacceptable for the enumeration of fecal coliforms in tropical fresh and marine waters. Thus, considering the high densities of fecal coliforms observed at most sites in Puerto Rico by all these methods, it would seem that these density estimates are, in many cases, grossly overestimating the degree of recent fecal contamination. Since Escherichia coli appears to be a normal inhabitant of tropical waters, fecal contamination may be indicated when none is present. Using fecal coliforms as an indicator is grossly inadequate for the detection of recent human fecal contamination and associated pathogens in both marine and fresh tropical waters.  相似文献   

16.
Several selective media currently used for the enumeration of Staphylococcus aureus from different sources were evaluated in order to establish their quantitative recovery, specificity and degree of selectivity, using different types of water samples. The highest selectivity and reliability in the enumeration of Staph. aureus from the samples was obtained on Borrego-Florido-Romero-0 (BFR-0) and KRANEP agars. The method that produced the highest recovery of Staph. aureus was BFR-0 agar with membrane filter and incubation at 36°C for 48–72 h.  相似文献   

17.
Several selective media currently used for the enumeration of Staphylococcus aureus from different sources were evaluated in order to establish their quantitative recovery, specificity and degree of selectivity, using different types of water samples. The highest selectivity and reliability in the enumeration of Staph. aureus from the samples was obtained on Borrego-Florido-Romero-0 (BFR-0) and KRANEP agars. The method that produced the highest recovery of Staph. aureus was BFR-0 agar with membrane filter and incubation at 36 degrees C for 48-72 h.  相似文献   

18.
The antimicrobial activity of cryptolepine is influenced by the type of medium employed, agitation and the presence of non-inhibitory concentrations of EDTA. The use of Mueller–Hinton broth (MHB), iso-sensitest broth and tryptone soya broth (TSB) produced lower minimum inhibitory concentrations (MICs) for some of the test organisms compared with nutrient broth or yeast dextrose broth (YDB). For example, a fourfold drop in MIC was recorded for Saccharomyces cerevisiae in MHB compared with the same organism tested in YDB. Agitation of the broths during incubation nearly always produced lower MICs for the bacteria, an eightfold decrease in MIC being recorded for Escherichia coli cultured in nutrient broth with agitation compared with a statically maintained culture. A non-inhibitory concentration (10−3 mol l−1) of disodium EDTA enhanced the antimicrobial activity of cryptolepine. Against E. coli NCTC 11560, an eightfold decrease in MIC and minimum bactericidal concentration (MBC) was recorded when tested in the presence of EDTA.  相似文献   

19.
Recovery of Escherichia coli from Chlorinated Secondary Sewage   总被引:18,自引:17,他引:1       下载免费PDF全文
Escherichia coli ATCC 27622 injured during chlorination of secondary sewage failed to produce colonies on membrane filters incubated on m-FC medium or to grow and produce gas in lactose broth. Thus, standard methods for the enumeration of total and fecal coliforms in water and wastes should not be applied to chlorinated effluents.  相似文献   

20.
AIMS: Enumeration of coliform bacteria and Escherichia coli is the most widely used method in the estimation of hygienic quality of drinking water. The yield of target bacteria and the species composition of different populations of coliform bacteria may depend on the method.Three methods were compared. METHODS AND RESULTS: Three membrane filtration methods were used for the enumeration of coliform bacteria in shallow well waters. The yield of confirmed coliform bacteria was highest on Differential Coliform agar, followed by LES Endo agar. Differential Coliform agar had the highest proportion of typical colonies, of which 74% were confirmed as belonging to the Enterobacteriaceae. Of the typical colonies on Lactose Tergitol 7 TTC agar, 75% were confirmed as Enterobacteriaceae, whereas 92% of typical colonies on LES Endo agar belonged to the Enterobacteriaceae. LES Endo agar yielded many Serratia strains, Lactose Tergitol 7 TTC agar yielded numerous strains of Rahnella aquatilis and Enterobacter, whereas Differential Coliform agar yielded the widest range of species. CONCLUSION: The yield of coliform bacteria varied between methods. Each method compared had a characteristic species distribution of target bacteria and a typical level of interference of non-target bacteria. Identification with routine physiological tests to distinct species was hampered by the slight differences between species. High yield and sufficient selectivity are difficult to achieve simultaneously, especially if the target group is diverse. SIGNIFICANCE AND IMPACT OF THE STUDY: The results showed that several aspects of method performance should be considered, and that the target group must be distinctly defined to enable method comparisons.  相似文献   