首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Hong Z  Fan G  Chai Y  Yin X  Wu Y 《Chirality》2005,17(5):293-296
Tetrahydropalmatine (THP) is a biologically active ingredient isolated from a traditional Chinese herb Rhizoma corydalis (yanhusuo). THP is a racemic mixture which contains 50% of the (+) and 50% of (-) enantiomer. The (-) enantiomer accounts for most of the analgesic effects. Plasma concentrations of THP enantiomers were analyzed by chiral high-performance liquid chromatography (HPLC) on a Chiralcel OJ column with quantification by UV at 230 nm. The method was used to determine the pharmacokinetics of THP enantiomers in rats and dogs after oral administration of rac-THP or (-)-THP. The pharmacokinetic profiles of the two enantiomers after dosing with rac-THP were significantly different both in rats and dogs. The mean C(max) and AUC(0-infinity) values in rats were 1.93 +/- 0.36 microg/ml and 6.65 +/- 2.34 microg x h/ml for the (-) enantiomer, and 1.11 +/- 0.25 microg/ml and 2.03 +/- 0.45 microg x h/ml for the (+) enantiomer. The mean C(max) and AUC(0-infinity) in dogs were 1.60 +/- 0.81 microg/ml and 9.88 +/- 2.58 microg x h/ml for the (-) enantiomer, while 0.36 +/- 0.21 microg/ml and 1.22 +/- 0.40 microg x h/ml for the (+) enantiomer. rac-THP at 40 mg/kg and (-)-THP at 20 mg/kg had very similar plasma concentration-time profiles, and C(max), AUC(0-infinity), and t(1/2) of the (-) enantiomer in both rats and dogs, indicating that the two treatments were equivalent with respect to the pharmacokinetic properties of the (-) enantiomer.  相似文献   

2.
A selective, accurate and reproducible high-performance liquid chromatographic (HPLC) method for the separation of individual enantiomers of DRF 2725 [R(+)-DRF 2725 and S(-)-DRF 2725 or ragaglitazar] was obtained on a chiral HPLC column (Chiralpak). During method optimization, the separation of enantiomers of DRF 2725 was investigated to determine whether mobile phase composition, flow-rate and column temperature could be varied to yield the base line separation of the enantiomers. Following liquid-liquid extraction, separation of enantiomers of DRF 2725 and internal standard (I.S., desmethyl diazepam) was achieved using an amylose based chiral column (Chiralpak AD) with the mobile phase, n-hexane-propanol-ethanol-trifluoro acetic acid (TFA) in the ratio of 89.5:4:6:0.5 (v/v). Baseline separation of DRF 2725 enantiomers and I.S., free from endogenous interferences, was achieved in less than 25 min. The eluate was monitored using an UV detector set at 240 nm. Ratio of peak area of each enantiomer to I.S. was used for quantification of plasma samples. Nominal retention times of R(+)-DRF 2725, S(-)-DRF 2725 and I.S. were 15.8, 17.7 and 22.4 min, respectively. The standard curves for DRF 2725 enantiomers were linear (R(2) > 0.999) in the concentration range 0.3-50 microg/ml for each enantiomer. Absolute recovery, when compared to neat standards, was 70-85% for DRF 2725 enantiomers and 96% for I.S. from rat plasma. The lower limit of quantification (LLOQ) for each enantiomers of DRF 2725 was 0.3 microg/ml. The inter-day precisions were in the range of 1.71-4.60% and 3.77-5.91% for R(+)-DRF 2725, S(-)-DRF 2725, respectively. The intra-day precisions were in the range of 1.06-11.5% and 0.58-12.7% for R(+)-DRF 2725, S(-)-DRF 2725, respectively. Accuracy in the measurement of quality control (QC) samples was in the range 83.4-113% and 83.3-113% for R(+)-DRF 2725, S(-)-DRF 2725, respectively. Both enantiomers and I.S. were stable in the battery of stability studies viz., bench-top (up to 6 h), auto-sampler (up to 12 h) and freeze/thaw cycles (n = 3). Stability of DRF 2725 enantiomers was established for 15 days at -20 degrees C. The application of the assay to a pharmacokinetic study of ragaglitazar [S(-)-DRF 2725] in rats is described. It was unequivocally demonstrated that ragaglitazar does not undergo chiral inversion to its antipode in vivo in rat plasma.  相似文献   

3.
Citalopram (CITA) is available as a racemic mixture and as a pure enantiomer. Its antidepressive action is related to the (+)-(S)-CITA and to the metabolite (+)-(S)-demethylcitalopram (DCITA). In the present investigation, a method for the analysis of CITA and DCITA enantiomers in human and rat plasma was developed and applied to the study of pharmacokinetics. Plasma samples (1 ml) were extracted at pH 9.0 with toluene:isoamyl alcohol (9:1, v/v). The CITA and DCITA enantiomers were analyzed by LC-MS/MS on a Chiralcel OD-R column. Recovery was higher than 70% for both enantiomers. The quantification limit was 0.1 ng/ml, and linearity was observed up to 500 ng/ml plasma for each CITA and DCITA enantiomer. The method was applied to the study of the kinetic disposition of CITA administered in a single oral dose of 20 mg to a healthy volunteer and in a single dose of 20 mg/kg (by gavage) to Wistar rats (n = 6 for each time). The results showed a higher proportion of the (-)-(R)-CITA in human and rat plasma, with S/R AUC ratios for CITA of 0.28 and 0.44, respectively. S/R AUC ratios of DCITA were 0.48 for rats and 1.04 for the healthy volunteer.  相似文献   

4.
Stereoselectivity of the pharmacokinetics of the nonsteroidal anti-inflammatory drug flobufen, 4-(2', 4'-difluorobiphenyl-4-yl)-2-methyl-4-oxobutanoic acid, was studied in male Wistar rats after intravenous administration. Pharmacokinetic parameters and chiral inversion of flobufen enantiomers were studied after a bolus injection of the racemate and individual enantiomers (5 mg/kg). Determinations of the enantiomers in rat plasma were performed using chiral HPLC (terguride column). After i.v. administration of flobufen racemate, plasma levels of R-enantiomer decreased more rapidly. The S-/R-enantiomer ratio of AUCs after rac-flobufen was 13.3. The total plasma clearance value of S-flobufen was more than 10-fold lower than R-flobufen. The other pharmacokinetic parameters of the enantiomers were also significantly different. While only traces of R-enantiomer (less than 1%) were detected in rat plasma after S-flobufen administration, considerable conversion to the S-enantiomer was found after injection of R-flobufen (R-enantiomer AUC/S-enantiomer AUC = 0.52). The results indicate substantial stereoselectivity in the disposition of flobufen enantiomers in the rat, which is, at least in part, attributed to chiral bioconversion.  相似文献   

5.
The method presented here is a high-performance liquid chromatography (HPLC)-UV detection method for the determination of baclofen R-(-)- and S-(+)-enantiomers in human plasma using a chiral separation technique. Baclofen enantiomers were extracted from human plasma with a reversed-phase solid-phase extraction (SPE) cartridge. The extract was then injected onto a HPLC system with a UV detection system set at 220 nm. The separation was achieved by using a 150x4.6 mm, 5 microm Phenomenex chirex 3216 chiral column with a mobile phase consisting of 0.4 mM CuSO(4) in acetonitrile-20 mM sodium acetate (17:83). The calibration curves were linear for both R-(-)- and S-(+)-enantiomers of baclofen in the concentration range of 20-5000 ng/ml. The average regressions were 0.9980 and 0.9991 for R-(-)- and S-(+)-baclofen, respectively. Inter-day precision was 3.3-5.2% for R-(-)-baclofen and 3.5-3.9% for S-(+)-baclofen at a concentration range of 60-4000 ng/ml. Intra-day precisions were 0.6-4.4 and 0.5-3.5% for R-(-)-baclofen and S-(+)-baclofen, respectively. The average extraction recovery was 81.6% for R-(-)-baclofen, 83.0% for S-(+)-baclofen and 94.0% for the internal standard (p-aminobenzoic acid). The limit of quantitation for both R-(-)- and S-(+)-baclofen in human plasma was 20 ng/ml. The method is simple and easy to operate with accuracy and reproducibility and it is suitable for pharmacokinetic studies.  相似文献   

6.
M Enquist  J Hermansson 《Chirality》1989,1(3):209-215
A method for the determination of (R)- and (S)-atenolol in human plasma and urine is described. The enantiomers of atenolol are extracted into dichloromethane containing 3% heptafluorobutanol followed by acetylation with acetic anhydride at 60 degrees C for 2 h. The acetylated enantiomers were separated on a chiral alpha 1-AGP column. Quantitation was performed using fluorescence detection. A phosphate buffer pH 7.1 (0.01 M phosphate) containing 0.25% (v/v) acetonitrile was used as mobile phase. The described procedure allows the detection of less than 6 ng of each enantiomer in 1 ml plasma. The relative standard deviation is 4.4% at 30 ng/ml of each enantiomer in plasma. The plasma concentration of (R)- and (S)-atenolol did not differ significantly in two subjects who received a single tablet of racemic atenolol. The R/S ratio of atenolol in urine was approximately 1.  相似文献   

7.
We have developed a simple, sensitive, specific and reproducible stereoselective high-performance liquid chromatography technique for analytical separation of cisapride enantiomers and measurement of cisapride enantiomers in human plasma. A chiral analytical column (ChiralCel OJ) was used with a mobile phase consisting of ethanol–hexane–diethylamine (35:64.5:0.5, v/v/v). This assay method was linear over a range of concentrations (5–125 ng/ml) of each enantiomer. The limit of quantification was 5 ng/ml in human plasma for both cisapride enantiomers, while the limit of detection was 1 ng/ml. Intra- and inter-day C.V.s did not exceed 15% for all concentrations except at 12.5 ng/ml for EII (+)-cisapride, which was 20 and 19%, respectively. The clinical utility of the method was demonstrated in a pharmacokinetic study of normal volunteers who received a 20 mg single oral dose of racemic cisapride. The preliminary pharmacokinetic data obtained using the method we describe here provide evidence for the first time that cisapride exhibits stereoselective disposition.  相似文献   

8.
A stereoselective high-performance liquid chromatographic (HPLC) method is described for the selective and sensitive quantitation in human plasma of R-(+)- and S-(−)-enantiomers of remoxipride. Remoxipride was extracted from basified plasma into hexane-methyl-tert.-butyl ether (20:80, v/v), washed with sodium hydroxide (1.0 M), then back-extracted into phosphoric acid (0.1 M). A structural analog of remoxipride was used as an internal standard. The sample extracts were chromatographed using a silica-based derivatized cellulose chiral column, Chiralcel OD-R, and a reversed-phase eluent containing 30–32% acetonitrile in 0.1 M potassium hexafluorophosphate. Ultraviolet (UV) absorbance detection was performed at 214 nm. Using 0.5-ml plasma aliquots, the method was validated in the concentration range 0.02-2.0 μg/ml and was applied in the investigation of systemic inversion of remoxipride enantiomers in man.  相似文献   

9.
L L Lee  A G Zacchei 《Chirality》1991,3(2):129-135
A stereospecific HPLC bioanalytical method was developed for quantitation of the enantiomers of MK-0571, a leukotriene D4 receptor antagonist. The procedure involves the addition of an internal standard analog to the biological matrix followed by extraction of the free acids into ethyl acetate. The acids are subsequently reacted with the homochiral reagent, (+)-(R)-alpha-(1-naphthyl)ethylamine (NEA) to form diastereomers. Following removal of excess reagent and side products by a dilute acid wash, the NEA-MK-0571 diastereomers are separated on a phenyl urea chiral column using a mobile phase containing hexane, isopropanol, and acetonitrile and are detected with a fluorescence detector. The sensitivity of the method is such that 50 ng of each enantiomer can be quantitated. In the 0.05 to 10 micrograms range the recoveries of the enantiomers of MK-0571 from plasma were 100.4 +/- 7.9% and 100.0 +/- 7.2%. NMR and mass spectral data confirmed the structure of the derivative. The method has been utilized in drug safety evaluation studies to demonstrate enantioselectivity in disposition of the enantiomers of MK-0571 in rats and monkeys but not in mice.  相似文献   

10.
Zhu W  Dang Z  Qiu J  Lv C  Jia G  Li L  Zhou Z 《Chirality》2007,19(8):632-637
The stereoselective toxicokinetics of ethofumesate enantiomers following a single intravenous (i.v.) administration at doses of 30 mg/kg were investigated in rabbits. Plasma concentrations of (+)- and (-)-ethofumesate were analyzed by a validated chiral HPLC method that involved extraction of plasma with organic solvent followed by separation on a cellulose-Tris-(3,5-dimethylphenylcarbamate)-based chiral column and quantification by UV absorbance at 230 nm. Plasma concentration-time curves after i.v. administration were best described by an open two-compartment model. The concentration of the (-)-enantiomer decreased more rapidly than that of the (+)-enantiomer. Significant differences in toxicokinetic parameters between the two enantiomers indicated that stereoselective behavior occurred with the (-)-enantiomer being preferentially metabolized and eliminated.  相似文献   

11.
A sensitive and specific liquid chromatography electrospray ionization-tandem mass spectrometry method for the enantioselective determination of the novel beta-adrenolytic compound, 1-(1-H-indol-4-yloxy)-3-{[2-(2-methoxyphenoxy)ethylo]amino} propan-2-ol, in rat plasma has been developed and validated. Chromatography was performed on a reversed-phase Chiralcel OD-RH analytical column (150x4.6 mm, 5 microm, Daicel Chemical Industries, Tokyo, Japan) with isocratic elution using a mobile phase containing acetonitrile and water with 0.01% formic acid. Detection was achieved by an Applied Biosystems MDS Sciex (Concord, Ontario, Canada) API 2000 triple quadrupole mass spectrometer. Electrospray ionization (ESI) was used for ion production. The limit of detection in the MRM mode was found to be 1.25 ng/ml. The limit of quantification of both enantiomers was 2.5 ng/ml. The precision and accuracy for both intra- and inter-day determination of 2F109 enantiomers ranged from 2.6 to 12% and from 89.1 to 107.1%. This analytical method allowed us to carry out pharmacokinetic studies in rats. Our findings demonstrate that 2F109 shows stereoselective disposition in rat plasma after i.v. administration. The terminal half-lives of (+)-(R)-2F109 and (-)-(S)-2F109 were 33.5 and 42.6 min, respectively. The AUC0-inf of (+)-(R)-2F109 exceeded that of (-)-(S)-2F109.  相似文献   

12.
We used a novel chromatographic method to rapidly and simply characterize the pharmacokinetics of benidipine enantiomers in human plasma. The stereoisomers of benidipine were extracted from plasma using diethylether under alkaline conditions. After evaporating the organic layer, the residue was reconstituted in the mobile phase (methanol:acetic acid:triethylamine, 100:0.01:0.0001, v/v/v). The enantiomers in the extract were separated on a macrocyclic antibiotic (Vancomycin) chiral stationary phase column. The mobile phase was eluted at 1 ml/min and was split by an interface. One-fifth of the eluent was used to quantify both isomers in a tandem mass spectrometer in multiple reaction-monitoring mode. The coefficient of variation of the precision of the assay was less than 8%, the assay accuracy was between 93.4 and 113.3%, and the limit of detection was 0.05 ng/ml for 1 ml of plasma. The method described above was used to measure the concentration of both benidipine enantiomers in plasma from healthy subjects who received a single oral dose of a racemate of 8 mg benidipine. The C(max) and AUC(inf) values of (+)-alpha benidipine were higher than those of (-)-alpha benidipine by 1.96- and 1.85-fold, respectively (p<0.001), whereas, the T(max) and t(1/2) for each of the benidipine stereoisomers were not significantly different.  相似文献   

13.
A sensitive and enantioselective method was developed and validated for the determination of ondansetron enantiomers in human plasma using enantioselective liquid chromatography-tandem mass spectrometry. The enantiomers of ondansetron were extracted from plasma using ethyl acetate under alkaline conditions. HPLC separation was performed on an ovomucoid column using an isocratic mobile phase of methanol-5 mM ammonium acetate-acetic acid (20:80:0.02, v/v/v) at a flow rate of 0.40 mL/min. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, using the transitions of m/z 294-->170 for ondansetron enantiomers, and m/z 285-->124 for tropisetron (internal standard). The method was linear in the concentration range of 0.10-40 ng/mL for each enantiomer using 200 microL of plasma. The lower limit of quantification (LLOQ) for each enantiomer was 0.10 ng/mL. The intra- and inter-assay precision was 3.7-11.6% and 5.6-12.3% for R-(-)-ondansetron and S-(+)-ondansetron, respectively. The accuracy was 100.4-107.1% for R-(-)-ondansetron and 103.3-104.9% for S-(+)-ondansetron. No chiral inversion was observed during the plasma storage, preparation and analysis. The method was successfully applied to characterize the pharmacokinetic profiles of ondansetron enantiomers in healthy volunteers after an intravenous infusion of 8 mg racemic ondansetron.  相似文献   

14.
A stereoselective reversed-phase HPLC assay to determine S-(-) and R-(+) enantiomers of esmolol in human plasma was developed. The method involved liquid-liquid extraction of esmolol from human plasma, using S-(-)-propranolol as the internal standard, and employed 2,3,4,6-tetra-O-acetyl-beta-d-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The derivatized products were separated on a 5-microm reversed-phase C18 column with a mixture of acetonitrile/0.02 mol/L phosphate buffer (pH 4.5) (55:45, v/v) as mobile phase. The detection of esmolol derivatives was made at lambda=224 nm with UV detector. The assay was linear from 0.035 to 12 microg/ml for each enantiomer. The analytical method afforded average recoveries of 94.8% and 95.5% for S-(-)- and R-(+)-esmolol, respectively. For each enantiomer, the limit of detection was 0.003 microg/ml and the limit of quantification for the method was 0.035 microg/ml (RSD<14%). The reproducibility of the assay was satisfactory.  相似文献   

15.
Nine patients taking oral doses of 10 mg/12 h rac-pindolol as part of their treatment for hypertension in pregnancy were recruited for the study. Maternal and fetal gestational age ranged from 20-38 years and 28-41 weeks, respectively. Blood was collected from the umbilical cord vein and from the mother from zero to 12 h after drug administration. Urine was collected for 12 h after rac-pindolol administration at the following intervals: 0-3, 3-6, 6-9, and 9-12 h. Plasma and urine concentrations of the pindolol enantiomers were determined by HPLC using a Chiralpak AD chiral column and fluorescence detection. The data were fitted to a one-compartment model and differences between (+)-R and (-)-S enantiomers were compared by the paired t-test (P < 0.05). Mean results are reported. The disposition of pindolol in maternal plasma was stereoselective, with higher AUC(SS)0-12 (84.34 vs. 95.69 ng.h/ml) and Cl(R) values (9.16 vs. 10.85 L/h) and lower Vd/f (251.38 vs. 225.17 L) and Cl/f (62.48 vs. 55.74 L/h) for the (+)-R pindolol. The transplacental distribution of pindolol was not stereoselective. Cord, plasma, and presumably fetal, concentrations of the pindolol enantiomers were 56% of the maternal plasma concentrations up to 6 h after the last dose.  相似文献   

16.
Enantiomeric resolution of teratolol was achieved on a vancomycin macrocyclic antibiotic chiral stationary phase known as Chirobiotic V with UV detection set at 220 nm. The polar ionic mobile phase (PIM) consisted of methanol-glacial acetic acid-triethylamine (100:0.01:0.015, v/v/v) has been used at a flow rate of 0.8 ml min(-1) . The calibration curves in plasma were linear over the range of 5-500 ng ml(-1) for each enantiomer with detection limit of 2 ng ml(-1) . The proposed method was validated in compliance with the international conference on harmonization (ICH) guidelines. The developed method applied for the trace analyses of tertatolol enantiomers in plasma and for the pharmacokinetic study of tertatolol enantiomers in rat plasma. The assay proved to be suitable for therapeutic drug monitoring and chiral quality control for tertatolol formulations by HPLC.  相似文献   

17.
The enantioselective high-performance liquid chromatography (HPLC) of three racemic 3-hydroxybenzodiazepines, oxazepam (Oxa), lorazepam (Lor), and temazepam (Tem), is a difficult operation because of the spontaneous chiral inversion in polar solvent. To solve this problem, we have developed an HPLC method based on a chiral Cyclobond I-2000 RSP column, maintained at 12 degrees C, and a reversed mobile phase (acetonitrile in 1% triethylamine acetate buffer, TEAA) at a flow rate of 0.4 ml/min. Peaks were detected by a photodiode-array detector at 230 nm for quantification and by an optical rotation detector for identification of (+) and (-) enantiomers. The results showed that peak resolutions of Oxa, Lor, and Tem enantiomers, analyzed under the same conditions, were 3.2, 2.0, and 1.8, respectively. For the determination of Oxa enantiomers in plasma of rabbits, extraction with diethyl ether at pH 1.5, a polar organic mobile phase, and a Cyclobond I-2000 SP column were used. Other analytical conditions were the same as previously described. Blood samples were immediately cooled at 4 degrees C and centrifuged at 0 degrees C for the collection of plasma. The results showed a difference in plasma S(+)- and R(-)-oxazepam concentrations in rabbits. No racemization of S(+)- or R(-)-Oxa enantiomers, added alone to blank plasma, was observed after extraction and enantioselective HPLC analysis.  相似文献   

18.
Guan J  Yang J  Li J  Li X  Li F 《Chirality》2009,21(6):613-618
The enantioselective pharmacokinetics of tenatoprazole were studied in Wistar rats after the administration of a single oral dose of rac-tenatoprazole. Serial plasma samples were collected; and the pharmacokinetic behavior of each enantiomer was characterized using a sequential achiral and chiral liquid chromatographic method. Tenatoprazole was extracted from a small aliquot of plasma (100 microl) by one-step extraction using hexane-dichloromethane-isopropanol (20:10:1, v/v/v) as extract solvent. Plasma drug concentration-time data were analyzed for each enantiomer by using a noncompartmental method. The AUC(0-infinity) and C(max) values of (+)-tenatoprazole were significantly greater than those of (-)-tenatoprazole (P < 0.001). The mean AUC(0-infinity) value of (+)-tenatoprazole was 7.5 times greater than that of (-)-tenatoprazole after oral administration of rac-tenatoprazole to rats at a dose of 5 mg/kg. There are also significant differences in t(1/2) and CL/F (P < 0.01 and P < 0.001, respectively) values between enantiomers. This study suggests that the pharmacokinetics of tenatoprazole are enantioselective in rats.  相似文献   

19.
A stereoselective reversed-phase HPLC assay to quantify S-(−) and R-(+) enantiomers of propranolol and 4-hydroxypropranolol in human plasma was developed. The method involved liquid–liquid extraction for sample clean-up and employed 2,3,4,6-tetra-O-acetyl-β-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The internal standard used was 4-methylpropranolol. The derivatized products were separated on an Altex C18 column using a mixture of acetonitrile–water–phosphoric acid–triethylamine (58:42:0.1:0.06 and 50:50:0.15:0.06, v/v, for propranolol and 4-hydroxypropranolol, respectively) as mobile phase. The detection of propranolol derivatives was made at λex=280 nm and λem=325 nm, and the corresponding 325 and 400 nm were used for 4-hydroxypropranolol derivatives. The assay was linear from 1 to 100 ng/ml and from 2 to 50 ng/ml using 0.5 ml of human plasma for propranolol and 4-hydroxypropranolol enantiomers, respectively. The present assay is used to quantify the enantiomers of propranolol and 4-hydroxypropranolol, respectively, in human plasma for pharmacokinetic studies.  相似文献   

20.
Clenbuterol is a relatively selective beta2-adrenergic partial agonist that has bronchodilator activity. This drug has been investigated as a potential countermeasure to microgravity- or disuse-induced skeletal muscle atrophy because of presumed anabolic effects. The purpose of this study was to: 1) analyze the anabolic effect of clenbuterol's (-)-R and (+)-S enantiomers (0.2 mg/kg) on muscles (cardiac and skeletal) and other organs; and 2) compare responses of enantiomers to the racemate (0.4 mg/kg and 1.0 mg/kg). Male Sprague Dawley rats were treated with: a) racemic clenbuterol (rac-clenbuterol, 0.4 or 1.0 mg/kg); b) enantiomers [clenbuterol (-)-R or (+)-S]; or c) vehicle (1.0 mL/kg buffered saline). Anabolic activity was determined by measuring tissue mass and protein content. HPLC teicoplanin chiral stationary phase was used to directly resolve racemic clenbuterol to its individual enantiomers. In skeletal muscle, both enantiomers had equal anabolic activity, and the effects were muscle- and anatomic region-specific in magnitude. Although the enantiomers did not affect the ventricular mass to body weight ratio, clenbuterol (+)-S induced a small but significant increase in ventricular mass. Both clenbuterol enantiomers produced significant increases in skeletal muscle mass, while being less active in producing cardiac ventricular muscle hypertrophy than the racemic mixture.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号