首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Computed tomography (CT) is the standard imaging modality in radiation therapy treatment planning (RTP). However, magnetic resonance (MR) imaging provides superior soft tissue contrast, increasing the precision of target volume selection. We present MR-only based RTP for a rat brain on a small animal radiation research platform (SARRP) using probabilistic voxel classification with multiple MR sequences. Six rat heads were imaged, each with one CT and five MR sequences. The MR sequences were: T1-weighted, T2-weighted, zero-echo time (ZTE), and two ultra-short echo time sequences with 20 μs (UTE1) and 2 ms (UTE2) echo times. CT data were manually segmented into air, soft tissue, and bone to obtain the RTP reference. Bias field corrected MR images were automatically segmented into the same tissue classes using a fuzzy c-means segmentation algorithm with multiple images as input. Similarities between segmented CT and automatic segmented MR (ASMR) images were evaluated using Dice coefficient. Three ASMR images with high similarity index were used for further RTP. Three beam arrangements were investigated. Dose distributions were compared by analysing dose volume histograms. The highest Dice coefficients were obtained for the ZTE-UTE2 combination and for the T1-UTE1-T2 combination when ZTE was unavailable. Both combinations, along with UTE1-UTE2, often used to generate ASMR images, were used for further RTP. Using 1 beam, MR based RTP underestimated the dose to be delivered to the target (range: 1.4%-7.6%). When more complex beam configurations were used, the calculated dose using the ZTE-UTE2 combination was the most accurate, with 0.7% deviation from CT, compared to 0.8% for T1-UTE1-T2 and 1.7% for UTE1-UTE2. The presented MR-only based workflow for RTP on a SARRP enables both accurate organ delineation and dose calculations using multiple MR sequences. This method can be useful in longitudinal studies where CT’s cumulative radiation dose might contribute to the total dose.  相似文献   

2.
In this work, dose measurements were performed to evaluate an external radiotherapy treatment plan and, particularly, to validate dose calculations for a lung lesion case. Doses were calculated by the Varian Eclipse treatment planning system using the AAA anisotropic analytical algorithm. The measurements were performed using a Rando anthropomorphic phantom and TLD700 thermoluminescent dosimeters. The comparison between doses calculated and doses measured by means of thermoluminescence (TL) shows compatibility except for a few points, due to the limitations in the heterogeneity correction used for the case studied here. The deviation between the calculated and measured doses is about 6.5% for low (<?0.5 Gy) doses and about 1% for higher doses (>?0.5 Gy).The deviation between AAA-calculated and TL-measured doses was also found to be higher in proximity to heterogeneous tissue interfaces.  相似文献   

3.
PurposeTo develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the Small Animal Radiation Research Platform (SARRP).Methods and materialsA QA phantom was developed for carrying out daily, monthly and annual QA tasks including: imaging, dosimetry and treatment planning system (TPS) performance evaluation of the SARRP. The QA phantom consists of 15 (60 × 60 × 5 mm3) kV-energy tissue equivalent solid water slabs. The phantom can incorporate optically stimulated luminescence dosimeters (OSLD), Mosfet or film. One slab, with inserts and another slab with hole patterns are particularly designed for image QA.ResultsOutput constancy measurement results showed daily variations within 3%. Using the Mosfet in phantom as target, results showed that the difference between TPS calculations and measurements was within 5%. Annual QA results for the Percentage depth dose (PDD) curves, lateral beam profiles, beam flatness and beam profile symmetry were found consistent with results obtained at commissioning. PDD curves obtained using film and OSLDs showed good agreement. Image QA was performed monthly, with image-quality parameters assessed in terms of CBCT image geometric accuracy, CT number accuracy, image spatial resolution, noise and image uniformity.ConclusionsThe results show that the developed QA phantom can be employed as a tool for comprehensive performance evaluation of the SARRP. The study provides a useful reference for development of a comprehensive quality assurance program for the SARRP and other similar small animal irradiators, with proposed tolerances and frequency of required tests.  相似文献   

4.
For the small animal radiation research platform (SARRP) with X-ray beams in the medium energy range (tube operating voltage at 220 kVp), reference dosimetry is based on the AAPM TG-61 recommendations following the in-phantom method. The objective of this study was to evaluate the feasibility of the Fricke solution as a dosimeter to determine the absorbed dose to water. Feasibility studies at this X-ray energy range are not widely available. We evaluated the accuracy, dose linearity and dose rate dependence in a comparison with an NE 2571 Farmer ionization chamber (IC) and measurements in water. The G(Fe3+) factor was calculated from the curve fitting of the chemical yields for two radioactive sources (192Ir and 60Co) and one X-ray system with a tube operating at 150 and 250 kVp. The same methodology was followed for the dependence of the G(Fe3+) value on the energy and the dose agreement assessment for 180 and 200 kVp in the SARRP. The Fricke system exhibits a good linear response over the range of 5–70 Gy and an accuracy better than 2% for a 2 Gy/min dose rate. The dose rate dependence is smaller than 1% for dose rates greater than 1 Gy/min. The dependence of the G(Fe3+) value on the energy is smaller than 0.41%, with dose agreements better than 2%. The feasibility of the dosimeter for measurements at high doses and high dose rates makes it a suitable tool for dosimetric verifications in several preclinical irradiation configurations.  相似文献   

5.
AimTo present a proposed gastric cancer intensity-modulated radiotherapy (IMRT) treatment planning protocol for an institution that have not introduced volumetric modulated arc therapy in clinical practice. A secondary aim was to determine the impact of 2DkV set-up corrections on target coverage and organ at risk (OAR).Methods and MaterialsTwenty consecutive patients were treated with a specially-designed non-coplanar 7-field IMRT technique. The isocenter-shift method was used to estimate the impact of 2DkV-based set-up corrections on the original base plan (BP) coverage. An alternative plan was simulated (SP) by taking into account isocenter shifts. The SP and BP were compared using dose-volume histogram (DVH) plots calculated for the internal target volume (ITV) and OARs.ResultsBoth plans delivered a similar mean dose to the ITV (100.32 vs. 100.40%), with no significant differences between the plans in internal target coverage (5.37 vs. 4.96%). Similarly, no significant differences were observed between the maximal dose to the spinal cord (67.70 and 67.09%, respectively) and volume received 50% of the prescribed dose of: the liver (62.11 vs. 59.84%), the right (17.62 vs. 18.58%) and left kidney (29.40 vs. 30.48%). Set-up margins (SM) were computed as 7.80 mm, 10.17 mm and 6.71 mm in the left-right, cranio-caudal and anterior-posterior directions, respectively.ConclusionPresented IMRT protocol (OAR dose constraints with selected SM verified by 2DkV verification) for stomach treatment provided optimal dose distribution for the target and the critical organs. Comparison of DVH for the base and the modified plan (which considered set-up uncertainties) showed no significant differences.  相似文献   

6.
The combination of radiotherapy treatments and breast reconstruction, using temporary tissue expanders, generates several concerns due to the presence of a magnetic valve inside the radiation field. The objective of this work is to evaluate a radiotherapy treatment planning for a patient using a tissue expander. Isodose curve maps, obtained using radiochromic films, were compared to the ones calculated with two different dose calculation algorithms of the Eclipse radiotherapy Treatment Planning System (TPS), considering the presence or absence of the heterogeneity. The TPS calculation considering the presence of the heterogeneity shows changes around 5% in the isodose curves when they were compared with the calculation without heterogeneity correction. This calculation did not take in account the real density value of the heterogeneity. This limitation was quantified to be around 10% in comparison with the TPS calculation and experimental measurements using the radiochromic film. These results show that the magnetic valve should be taken in account in dose calculations of the TPS. With respect to the AAA and Pencil Beam Convolution algorithms, when the calculation is compared with the real distribution, AAA presents a distribution more similar to experimental dose distribution.  相似文献   

7.
Myocardial blood flow is unevenly distributed, but the cause of this heterogeneity is unknown. Heterogeneous blood flow may reflect heterogeneity of oxygen demand. The aim of the present study was to assess the relation between oxygen consumption and blood flow in small tissue regions in porcine left ventricle. In seven male, anesthetized, open-chest pigs, local oxygen consumption was quantitated by computational model analysis of the incorporation of 13C in glutamate via the tricarboxylic acid cycle during timed infusion of [13C]acetate into the left anterior descending coronary artery. Blood flow was measured with radioactive microspheres before and during acetate infusion. High-resolution nuclear magnetic resonance 13C spectra were obtained from extracts of tissue samples (159 mg mean dry wt) taken at the end of the acetate infusion. Mean regional myocardial blood flow was stable [5.0 +/- 1.6 (SD) and 5.0 +/- 1.4 ml.min(-1).g dry wt(-1) before and after 30 min of acetate infusion, respectively]. Mean left ventricular oxygen consumption measured with the NMR method was 18.6 +/- 7.7 micromol.min(-1).g dry wt(-1) and correlated well (r = 0.85, P = 0.02, n = 7) with oxygen consumption calculated from blood flow, hemoglobin, and blood gas measurements (mean 22.8 +/- 4.7 micromol.min(-1).g dry wt(-1)). Local blood flow and oxygen consumption were significantly correlated (r = 0.63 for pooled normalized data, P < 0.0001, n = 60). We calculate that, in the heart at normal workload, the variance of left ventricular oxygen delivery at submilliliter resolution is explained for 43% by heterogeneity in oxygen demand.  相似文献   

8.
PurposeThe purpose of this study was to compare the delivered dose to the expected intraoperative radiation therapy (IORT) dose with in vivo dosimetry. For IORT using electrons in accelerated partial breast irradiation, this is especially relevant since a high dose is delivered in a single fraction.MethodsFor 47 of breast cancer patients, in vivo dosimetry was performed with MOSFETs and/or GAFCHROMIC EBT2 films. A total dose of 23.33 Gy at dmax was given directly after completing the lumpectomy procedure with electron beams generated with an IORT dedicated mobile accelerator. A protection disk was used to shield the thoracic wall.ResultsThe results of in vivo MOSFET dosimetry for 27 patients and GAFROMIC film dosimetry for 20 patients were analysed. The entry dose for the breast tissue, measured with MOSFETs, (mean value 22.3 Gy, SD 3.4%) agreed within 1.7% with the expected dose (mean value 21.9 Gy). The dose in breast tissue, measured with GAFCHROMIC films (mean value 23.50 Gy) was on average within 0.7% (SD = 3.7%, range −5.5% to 5.6%) of the prescribed dose of 23.33 Gy.ConclusionsThe dose measured with MOSFETs and GAFROMIC EBT2 films agreed well with the expected dose. For both methods, the dose to the thoracic wall, lungs and heart for left sided patents was lower than 2.5 Gy even when 12 MeV was applied. The positioning time of GAFCHROMIC films is negligible and based on our results we recommend its use as a standard tool for patient quality assurance during breast cancer IORT.  相似文献   

9.
Dynamic capacitance of epicardial coronary arteries in vivo   总被引:2,自引:0,他引:2  
The dynamic capacitance of epicardial coronary arteries (i.d. greater than or equal to 0.4 mm) in vivo was assessed from the volume stiffness and volume of these arteries. The volume stiffness was derived from the pressure wave front velocity as determined in dogs by measuring the delay time between the pressure pulses recorded proximal and distal to a segment of the anterior descending branch of the left coronary artery. The pressure pulse was generated elsewhere in the arterial system during diastole. The volume of the epicardial coronary arteries was calculated from the lengths and diameters as measured in araldite casts, making corrections for in-vitro/in-vivo differences in dimensions. The dynamic capacitance of the right coronary artery, and the anterior descending and circumflex branches of the left coronary artery at an arterial pressure of 13.3 kPa and a frequency between 7 and 30 Hz was found to be 0.0024 +/- 0.0013, 0.0062 +/- 0.0028 and 0.0079 +/- 0.0035 mL/kPa (mean +/- SD), respectively. The total capacitance of the epicardial coronary arteries was calculated to be (0.007 mL/kPa)/100 g, which is small as compared to the total capacitance of the coronary vasculature, including the intramyocardial compartment, which is in the order of (0.5 mL/kPa)/100 g [1].  相似文献   

10.
An increasing number of studies have shown that post-mastectomy radiotherapy presents benefits associated with the patients survival and a significant fraction of the treated patients makes use of tissue expanders for breast reconstruction. Some models of tissue expanders have a magnetic disk on their surface that constitutes heterogeneity in the radiation field, which can affect the dose distribution during the radiotherapy treatment. In this study, the influence of a metallic heterogeneity positioned in a breast tissue expander was evaluated by means of Monte Carlo simulations using the MCNPX code and using Eclipse treatment planning system. Deposited energy values were calculated in structures which have clinical importance for the treatment. Additionally, the effect in the absorbed energy due to backscattering and attenuation of the incident beam caused by the heterogeneity, as well as due to the expansion of the prosthesis, was evaluated in target structures for a 6 MV photon beam by simulations. The dose distributions for a breast treatment were calculated using a convolution/superposition algorithm from the Eclipse treatment planning system. When compared with the smallest breast expander volume, underdosage of 7% was found for the largest volume of breast implant, in the case of frontal irradiation of the chest wall, by Monte Carlo simulations. No significant changes were found in dose distributions for the presence of the heterogeneity during the treatment planning of irradiation with an opposed pair of beams. Even considering the limitation of the treatment planning system, the results obtained with its use confirm those ones found by Monte Carlo simulations for a tangent beam irradiation. The presence of a heterogeneity didńt alters the dose distributions on treatment structures. The underdosage of 7% observed with Monte Carlo simulations were found for irradiation at 0°, not used frequently in a clinical routine.  相似文献   

11.
This study explores how the metal materials of the applicator influence the dose distribution when performing brachytherapy for cervical cancer. A pinpoint ionization chamber, Monte Carlo code MCNPX, and treatment planning system are used to evaluate the dose distribution for a single Ir-192 source positioned in the tandem and ovoid. For dose distribution in water with the presence of the tandem, differences among measurement, MCNPX calculation and treatment planning system results are <5%. For dose distribution in water with the presence of the ovoid, the MCNPX result agrees with the measurement. But the doses calculated from treatment planning system are overestimated by up to a factor of 4. This is due to the shielding effect of the metal materials in the applicator not being considered in the treatment planning system. This result suggests that the treatment planning system should take into account corrections for the metal materials of the applicator in order to improve the accuracy of the radiation dose delivered.  相似文献   

12.
To study transport of steroids by erythrocytes, the tissue uptake of erythrocyte-associated testosterone and corticosterone was studied in vivo using a single injection technique into the carotid artery of rats. A brain uptake index (BUI) was calculated by dividing the ratio of [3H]steroid to [14C]butanol (internal reference) in the brain tissue by that in the injection material, and multiplying by 100%. BUIs of testosterone and corticosterone in an erythrocyte suspension were 131 +/- 3% (mean +/- SE, n = 6) and 57.0 +/- 2.7% (n = 6), respectively, which were greater than those in buffer (100 +/- 4%; n = 4, P less than 0.01 and 39.8 +/- 4.6%; n = 4, P less than 0.01, respectively). The erythrocyte accounted for 83.9% and 76.7% of the total testosterone and corticosterone delivered to the tissues, respectively, when calculated on the assumption that the BUIs of steroid in buffer and in the supernatant of an erythrocyte suspension are the same. BUIs of corticosterone in hemolysate and in a suspension of erythrocyte plasma membranes (60.8 +/- 7.0%; n = 4 and 69.5 +/- 3.7%; n = 4, respectively) were also greater than those in buffer (P less than 0.05 and P less than 0.01, respectively). Our results suggest that the erythrocyte-associated component of testosterone and corticosterone are delivered to the tissue of rat brain, and that their membranes may play a major role in their capacity to transport steroids to the tissues.  相似文献   

13.
Radiopharmaceuticals are distributed nonuniformly in tissue. While distributions of radioactivity often appear uniform at the organ level, in fact, microscopic examination reveals that only a fraction of the cells in tissue are labeled. Labeled cells and unlabeled cells often receive different absorbed doses depending on the extent of the nonuniformity and the characteristics of the emitted radiations. The labeled cells receive an absorbed dose from radioactivity within the cell (self-dose) as well as an absorbed dose from radioactivity in surrounding labeled cells (cross-dose). Unlabeled cells receive only a cross-dose. In recent communications, a multicellular cluster model was used to investigate the lethality of microscopic nonuniform distributions of 131I iododeoxyuridine (131IdU). For a given mean absorbed dose to the tissue, the dose response depended on the percentage of cells that were labeled. Specifically, when 1, 10 and 100% of the cells were labeled, a D37 of 6.4, 5.7 and 4.5 Gy, respectively, was observed. The reason for these differences was recently traced to differences in the cellular response to the self- and cross-doses delivered by 131IdU. Systematic isolation of the effects of self-dose resulted in a D37 of 1.2 +/- 0.3 Gy. The cross-dose component yielded a D37 of 6.4 +/- 0.5 Gy. In the present work, the overall survival of multicellular clusters containing 1, 10 and 100% labeled cells is modeled using a semi-empirical approach that uses the mean lethal self- and cross-doses and the fraction of cells labeled. There is excellent agreement between the theoretical model and the experimental data when the surviving fraction is greater than 1%. Therefore, when the distribution of 131I in tissue is nonuniform at the microscopic level, and the cellular response to self- and cross-doses differs, multicellular dosimetry can be used successfully to predict biological response, whereas the mean absorbed dose fails in this regard.  相似文献   

14.
In head computed tomography, radiation upon the eye lens (as an organ with high radiosensitivity) may cause lenticular opacity and cataracts. Therefore, quantitative dose assessment due to exposure of the eye lens and surrounding tissue is a matter of concern. For this purpose, an accurate eye model with realistic geometry and shape, in which different eye substructures are considered, is needed. To calculate the absorbed radiation dose of visual organs during head computed tomography scans, in this study, an existing sophisticated eye model was inserted at the related location in the head of the reference adult male phantom recommended by the International Commission on Radiological Protection (ICRP). Then absorbed doses and distributions of energy deposition in different parts of this eye model were calculated and compared with those based on a previous simple eye model. All calculations were done using the Monte Carlo code MCNP4C for tube voltages of 80, 100, 120 and 140 kVp. In spite of the similarity of total dose to the eye lens for both eye models, the dose delivered to the sensitive zone, which plays an important role in the induction of cataracts, was on average 3% higher for the sophisticated model as compared to the simple model. By increasing the tube voltage, differences between the total dose to the eye lens between the two phantoms decrease to 1%. Due to this level of agreement, use of the sophisticated eye model for patient dosimetry is not necessary. However, it still helps for an estimation of doses received by different eye substructures separately.  相似文献   

15.
Godoy JA  Jordano P 《Molecular ecology》2001,10(9):2275-2283
A long-standing challenge in studies of seed dispersal by animal frugivores has been the characterization of the spatial relationships between dispersed seeds and the maternal plants, i.e. the seed shadow. The difficulties to track unambiguously the origin of frugivore-dispersed seeds in natural communities has been considered an unavoidable limitation of the research field and precluded a robust analysis of the direct consequences of zoochory. Here we report that the multilocus genotype at simple sequence repeat (SSR; microsatellite) loci of the woody endocarp, a tissue of maternal origin, provides an unequivocal genetic fingerprint of the source tree. By comparing the endocarp genotype against the complete set of genotypes of reproductive trees in the population, we could unambiguously identify the source tree for 82.1% of the seeds collected in seed traps and hypothesize that the remaining 17.9% of sampled seeds come from other populations. Identification of the source tree for Prunus mahaleb seeds dispersed by frugivores revealed a marked heterogeneity in the genetic composition of the seed rain in different microhabitats, with a range of 1-5 distinct maternal trees contributing seeds to a particular landscape patch. Within-population dispersal distances ranged between 0 and 316 m, with up to 62% of the seeds delivered within 15 m of the source trees. Long distance dispersal events, detected by the exclusion of all reproductive trees in the population, accounted for up to 17.9% of the seeds sampled. Our results indicate strong distance limitation of seed delivery combined with infrequent long-distance dispersal events, extreme heterogeneity in the landscape pattern of genetic makeup, and a marked mosaic of multiple parentage for the seeds delivered to a particular patch.  相似文献   

16.
Fluoxetine (FLX) and norfluoxetine (NFLX) racemic mixtures were determined by reversed-phase liquid chromatography with fluorescence detection (lambda(exc)=227 nm, lambda(em)=305 nm). The calibration curves prepared from drug-free plasma and brain were linear in the range of 5-1000 ng ml(-1) and 100-40,000 ng g(-1) for doped samples, with detection limits of 3.2 and 2.1 ng ml(-1) in plasma and 31.5 and 26.1 ng g(-1) in brain tissue for FLX and NFLX, respectively. Enantiomer determination was carried out through normal phase HPLC-FD (lambda(exc)=224 nm, lambda(em)=336 nm) after precolumn chiral derivatization with R-1-(1-naphthyl)ethyl isocyanate. Standard curves also prepared in a drug-free matrix were linear for each enantiomer over the range of 2-1000 ng ml(-1) and 20-7000 ng g(-1) with detection limits for the four compounds ranging between 0.2 and 0.5 ng ml(-1) in plasma and between 3.0 and 8.2 ng g(-1) in brain tissue. In both methods the analytes were isolated from the biological matrix by a new solid-phase extraction procedure with recovery in plasma and brain over 90 and 87%, respectively. The repeatability of this extraction procedure was satisfactory within-day and between-day with CV<9.1%. This study also offered the opportunity to obtain an assessment of the potential relationships between the concentration of individual enantiomers of FLX and NFLX in plasma and brain tissue after chronic treatment with racemic FLX at a dose intended to mimic the human plasma concentration of FLX in standard clinical conditions, and therefore should make for more reliable extrapolation of neurochemical findings in other species.  相似文献   

17.
The performance of DNA barcoding as a tool for fast taxonomic verification in ecological assessment projects of small mammals was evaluated during a collecting trip to a lowland tropical rainforest site in Suriname. We also compared the performance of tissue sampling onto FTA CloneSaver cards vs. liquid nitrogen preservation. DNA barcodes from CloneSaver cards were recovered from 85% of specimens, but DNA degradation was apparent, because only 36% of sequence reads were long (over 600 bp). In contrast, cryopreserved tissue delivered 99% barcode recovery (97% > 600 bp). High humidity, oversampling or tissue type may explain the poor performance of CloneSaver cards. Comparison of taxonomic assignments made in the field and from barcode results revealed inconsistencies in just 3.4% of cases and most of the discrepancies were due to field misidentifications (3%) rather than sampling/analytical error (0.5%). This result reinforces the utility of DNA barcoding as a tool for verification of taxonomic identifications in ecological surveys, which is especially important when the collection of voucher specimens is not possible.  相似文献   

18.

Aim

Comparisons of integral dose delivered to the treatment planning volume and to the whole patient body during stereotactic, helical and intensity modulated radiotherapy of prostate.

Background

Multifield techniques produce large volumes of low dose inside the patient body. Delivered dose could be the result of the cytotoxic injuries of the cells even away from the treatment field. We calculated the total dose absorbed in the patient body for four radiotherapy techniques to investigate whether some methods have a potential to reduce the exposure to the patient.

Materials and methods

We analyzed CyberKnife plans for 10 patients with localized prostate cancer. Five alternative plans for each patient were calculated with the VMAT, IMRT and TomoTherapy techniques. Alternative dose distributions were calculated to achieve the same coverage for PTV. Integral Dose formula was used to calculate the total dose delivered to the PTV and whole patient body.

Results

Analysis showed that the same amount of dose was deposited to the treated volume despite different methods of treatment delivery. The mean values of total dose delivered to the whole patient body differed significantly for each treatment technique. The highest integral dose in the patient''s body was at the TomoTherapy and CyberKnife treatment session. VMAT was characterized by the lowest integral dose deposited in the patient body.

Conclusions

The highest total dose absorbed in normal tissue was observed with the use of a robotic radiosurgery system and TomoTherapy. These results demonstrate that the exposure of healthy tissue is a dosimetric factor which differentiates the dose delivery methods.  相似文献   

19.
Chronic coronary artery stenosis results in patchy necrosis in the dependent myocardium and impairs global and regional left ventricular (LV) function in rats in vivo. The aim of the present study was to compare regional myocardial blood flow (RMBF) and function (F) in poststenotic myocardium by using magnetic resonance imaging (MRI) and to compare MRI blood flow changes to histological alterations to assess whether RMBF in the viable poststenotic tissue remains normal. MRI was performed in 11 anesthetized Wistar rats with 2-wk stenosis of the left coronary artery. Postmortem, the extent of fibrotic tissue was quantified. Poststenotic RMBF was significantly reduced to 2.21 +/- 0.30 ml.g(-1).min(-1) compared with RMBF in the remote myocardium (4.05 +/- 0.50 ml.g(-1).min(-1)). A significant relationship between the poststenotic RMBF (%remote area) and the poststenotic F (%remote myocardium) was calculated (r = 0.61, P < 0.05). Assuming perfusion in scar tissue to be 32 +/- 5% of perfusion of remote myocardium, as measured in five additional rats, and that in remote myocardium to be 114 +/- 25% of that in normal myocardium, as assessed in five sham rats, the calculated perfusion in partially fibrotic tissue samples (35.7 +/- 5.2% of analyzed area) was 2.88 +/- 0.18 ml.g(-1).min(-1), whereas measured MRI perfusion was only 1.86 +/- 0.24 ml.g(-1).min(-1) (P < 0.05). These results indicate that resting perfusion in viable poststenotic myocardium is moderately reduced. Alterations in global and regional LV function are therefore secondary to both patchy fibrosis and reduced resting perfusion.  相似文献   

20.
The radiobiological effectiveness of an epithermal neutron beam is described using cell survival as the end point. The M67 epithermal neutron beam at the Nuclear Reactor Laboratory, Massachusetts Institute of Technology, that was used for clinical trials of boron neutron capture therapy was used to irradiate Chinese hamster ovary cells at seven depths in a water-filled phantom that simulated healthy tissue. No boron was added to the samples. Therefore, this experiment evaluates the biological effectiveness of the neutron and photon components, which comprise 80-95% of the dose to healthy tissue. Cell survival was dependent upon the depth in the phantom, as a result of moderation and attenuation of the epithermal neutron beam components by the overlying water. The results were compared with 250 kVp X irradiations to determine relative biological effectiveness values. Cell survival as a function of the dose delivered was lowest at the most shallow depth of 0.5 cm, and increased at depths of 1.5, 3, 4, 5.6, 6.6 and 8.1 cm. The gradual increase in cell survival with increasing depth in the phantom is due to the exponential drop of the fast-neutron intensity of the beam. These results are applicable to clinical boron neutron capture therapy Phase I/II trials in which healthy tissue toxicity was an end point.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号