首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The trickle-bed air biofilter (TBAB) performance for treating acrylonitrile (AN) and styrene (SR) mixtures was evaluated under different influent carbon loadings. In the pseudo steady state conditions, the elimination capacities of AN and SR increased but the removal efficiencies decreased with increased influent carbon loading. The removal efficiencies of AN were higher than those of SR, indicating that AN is a preferred substrate in the ANSR waste gas. More than 80% removal efficiencies were achieved with influent carbon loadings of AN and SR below 28 and 22 g/m(3)/h, respectively. The TBAB appears to be efficient for controlling ANSR emission with low to medium carbon loadings, and the effectiveness could be maintained over 175 days of laboratory operation. The elimination capacities of AN and SR for a pure volatile organic compound (VOC) feed were higher than those for a mixed VOC feed and the differences increased with increased influent VOC loading.  相似文献   

2.
Toluene and acetone mixtures are commonly encountered from the manufacture of semi-conductor or opto-electronic apparatus. This study attempts to employ a trickle-bed air biofilter (TBAB) for treating toluene and acetone mixtures under different gas flow rates and influent concentrations. In the pseudo-steady-states, the elimination capacities of toluene and acetone increased but the removal efficiencies decreased with the increase of influent carbon loading. The removal efficiencies of toluene were higher than those of acetone, indicating that toluene is a preferred substrate in the mixtures. Greater than 90% removal efficiencies were achieved with influent carbon loadings of toluene and acetone below 125 and 15 g/m3 h, respectively. The TBAB appears efficient for controlling toluene and acetone mixture with medium toluene and low acetone loadings. Applicable operating conditions of TBAB for treating mixed toluene and acetone emission are suggested.  相似文献   

3.
Chang K  Lu C 《Biodegradation》2003,14(1):9-18
The performance of trickle-bed air biofilter (TBAB) for the removal of isopropyl alcohol (IPA) was evaluated in concentrations varying from 100 to 500 ppmv and at empty-bed residence time (EBRT) varying from 20 to 90 s. Nearly complete IPA removal could be achieved for influent carbon loading between 6 and 88 g/mh. The TBAB appears efficient for controlling IPA emission under low-to-high carbon loading conditions. Carbon recoveries of 95-99% were achieved demonstrating the accuracy of results. Applicable operating conditions of TBAB for controlling IPA emission were suggested.  相似文献   

4.
Butyl acetate and xylene mixtures are commonly encountered from the manufacture of semi‐conductor or opto‐electronic apparatuses. The release of these substances into the ambient air may have a negative effect on the air quality. This study attempts to employ a trickle‐bed air biofilter for treating butyl acetate and xylene mixtures under different gas flow rates and influent concentrations. Almost complete VOC removal could be attained with influent carbon loadings of BA (butyl acetate) and X (xylene) below 40 and 15 g/m3h, respectively. As the influent carbon loadings of BA and X were increased up to 150 and 110 g/m3h, removal efficiencies higher than 80 % were achieved. Therefore, the trickle‐bed air biofilter (TBAB) appeared efficient in the control of emissions containing mixtures of butyl acetate and xylene with low to medium carbon loadings. The removal efficiencies of butyl acetate were higher than those of xylene, indicating that butyl acetate was the substrate preferred in the utilization of butyl acetate and xylene mixtures by the microorganisms. Carbon recoveries of 98–101 % were achieved, demonstrating the accuracy of results. The carbon mass rate of the liquid effluent was approximately two to three orders of magnitude less than that of the CO2 effluent, indicating that the dissolved VOCs and their derivatives in the leachate were present in a negligible amount in the reactor. Applicable operating conditions of the TBAB unit for treating BA and X mixtures were suggested.  相似文献   

5.
Effect of pH on anoxic sulfide oxidizing reactor performance   总被引:3,自引:1,他引:3  
The effects of pH on the performance of anoxic sulfide oxidizing (ASO) reactor were evaluated. Performance was investigated under various operational conditions at influent pH range of 4-11. At the influent pH of 7-7.5 during loading tests and HRT tests, the sulfide oxidation was partial. In general, the amount of sulfate formed decreased with the increasing sulfide and nitrite loadings. The bacterial communities in ASO reactors were more sensitive to acidic pH compared with alkaline pH, as nitrite and sulfide removal rates dropped significantly when exposed to acidic pH 3. High dissolved bisulfide ions, nitrite and excess of sulfate (>300 mg/L) might have inhibited the sulfide oxidation under highly acidic and alkaline conditions in the ASO reactor. Based on sulfide and nitrite removal efficiencies, the ASO reactor can be operated in a wide range of pH, i.e. 5-11.  相似文献   

6.
黄梦露  李战朋  王振 《生态学杂志》2017,28(12):4075-4082
通过逐步提高进水中的有机碳源浓度,探讨进水碳氮比(C/N)对基于亚硝化的全程自养脱氮(CANON)型潮汐流人工湿地(TFCW)脱氮效能及其微生物特性的影响.结果表明: 进水C/N可显著影响CANON型TFCW中脱氮功能微生物的数量与活性,进而影响其氮素转化速率.当进水C/N由0.0增至6.0时,TFCW中反硝化功能基因的丰度随之增加,系统反硝化性能提高,TFCW中逐渐形成同步亚硝化、厌氧氨氧化与反硝化(SNAD)耦合反应体系,其脱氮效果得以强化.当进水C/N>6.0时,好氧氨氧化菌活性受到抑制,数量逐渐减少,TFCW中的厌氧氨氧化作用与反硝化作用受阻,系统脱氮性能恶化.当进水C/N为6.0时,TFCW中的SNAD作用可得到最大限度的强化,其总氮(TN)去除率和去除负荷分别达(93.3±2.3)%和(149.30±8.00) mg·L-1·d-1,高于CANON系统中TN去除率的理论值.  相似文献   

7.
The effect of carbon sources and shock loadings have been studied using two sets of sequential upflow anaerobic sludge blanket (UASB) and rotating biological contactor (RBC) reactors viz., UASB-I followed by RBC-I and UASB-II followed by RBC-II for the removal of two different priority pollutants, 2-CP and 2,4-DCP present in simulated wastewaters. Sodium formate, sodium propionate, glucose and methanol were used separately as four different carbon sources in the feed as co-substrate. Methanol was found to be the best carbon source for UASB reactors showing 95% 2-CP and 81.1% 2,4-DCP removals. The carbon sources formate and propionate were not found suitable in UASB reactors as only 22.6-46.8% 2-CP and 41.9-42.8% 2,4-DCP removals were observed. With glucose as carbon source 93.7% 2-CP and 79.6% 2,4-DCP removals were observed in UASB reactors. For all the four carbon sources more than 97.6% 2-CP and 99.7% 2,4-DCP removals were observed in sequential reactors. Although all the four carbon sources could not serve as good carbon source for UASB reactor alone but could be successfully used by the sequential reactors for the removal of chlorophenols. The Performance of sequential reactors was also evaluated at five different chlorophenolic shock loadings. During shock loading study the concentration of chlorophenols in the wastewaters was increased to 45, 60, 75, 90 and 105 mg/l as compared to the normal feed containing 30 mg/l 2-CP or 2,4-DCP. During shock loading study complete removal of 2-CP and more than 99.6% removal of 2,4-DCP was observed in sequential reactors. Sequential reactors successfully withstood all the shock loadings and produced high quality effluents.  相似文献   

8.
One of the serious problems limiting the application of full-scale anaerobic fixed film processes is reactor startup. To better understand startup, studies with downflow stationary fixed film (DSFF) reactors were conducted to characterize the effects of influent concentration, support material, and surface-to-volume ratio on biofilm development and overall reactor performance. Materials with roughened surfaces gave the best startup performance and as expected increased surface area in the reactors led to more rapid increases in loading rates and higher ultimate loadings. Soluble influent COD concentrations between 5 x 10(3) and 2 x 10(4) mg/L influenced the rate of biofilm development. Lower COD concentrations resulted in faster development of the biofilm, even though ultimate loadings were not necessarily achieved as rapidly as in reactors fed higher strength wastes. No decrease in specific activity of the biofilms in each reactor was observed as the thickness of the biofilms increased to their maximum value at the ultimate loadings. The operation of reactors fed lower strength wastes was more stable than reactors receiving higher strength feeds at comparable loadings. Biofilm yield and activity, COD removals, suspended growth and activity, and other system parameters are discussed.  相似文献   

9.
The biological removal of phenol was studied in a multi-stage fixed-film reactor at phenol concentrations in the range of 190–900 mg l−1, hydraulic loadings of 0.02–0.22 m3 m−2 day−1 and temperatures of 20–35°C. Phenol removals up to 99.9% were obtained at 20°C but the efficiency decreased as the loading rate or phenol concentration was increased. The reactor coped with organic overloads better than with hydraulic overloads. Removal efficiencies increased as temperature was increased. Reactor performance was stable under extreme loadings and the reactor was capable of handling a ten-fold increase in loading with less than 20% loss in phenol removal efficiency. A large amount of attached biomass was retained in the reactor and was mostly present in the first stage where the majority of organic removal occurred.  相似文献   

10.
A packed cage rotating biological contactor (RBC) system was applied to treat wastewater containing Cl2 residue with concentration even up to 20 mg/L. However, Cl2 exhibited a negative effect on the efficiency of the system as evidenced by the decrease in the growth of bio-film. It could be concluded that the removal efficiency of the system decreased with the increase of Cl2 concentration or Cl2 loading. Due to inhibition of bio-film growth by the effects of Cl2 residue, the effluent suspended solids (SS) of the system was decreased. The bio-film was easily detached from the media under high growth rate conditions resulting in an increase of effluent SS. The COD and BOD5 removal efficiencies of the system under the highest organic and Cl2 loadings of 4.07 g BOD5/m2 d and 203.6 mg Cl2/m2 d, respectively, were 58.0+/-3.2% and 60.7+/-3.9%, respectively, while they were up to 83.3+/-1.8% and 85.8+/-2.0%, respectively, under the lowest organic and Cl2 loading of 2.04 g BOD5/m2 d and 25.5 mg Cl2/m2 d. However, the effluent SS of the system under above operating conditions was lower than 20 mg/L.  相似文献   

11.
In recent years, biofiltration has been increasingly applied as an air pollution control technology to minimize or eliminate emissions of volatile organic compounds from industrial sources and environmental remediation activities. Although the ability of this technology to maintain high removal efficiency during relatively steady loading conditions has been well established for many waste streams, relatively little research has focused on development of operating strategies that could improve treatment performance during transient loading conditions typical of industrial operations. In the research described herein, two operating strategies were evaluated over a period of 295 days in biofilters treating a model waste gas stream containing a two-component mixture of methyl ethyl ketone (MEK) and toluene. One biofilter was operated as a sequencing batch biofilter (SBB), and the other was operated as a conventional continuous-flow biofilter (CFB). During "normal" steady loading conditions, the model waste stream contained MEK concentrations ranging from 80 to 89 ppmv and toluene concentrations ranging from 28 to 30 ppmv. Both biofilter operating strategies resulted in stable long-term performance with greater than 99% contaminant removal during these normal loading conditions. On a regular basis, the influent MEK and toluene concentrations were temporarily increased to five times the normal influent concentration for the duration of 1 h to test performance during transient "shock loading" conditions. Biofilter performance during the model shock loading conditions demonstrate that SBB operating strategies can result in superior treatment in two important areas: (1) overall mass of contaminants removed and (2) minimum instantaneous removal efficiency.  相似文献   

12.
The primary objective of this study was to evaluate the performance of a 20 l lab scale anaerobic hybrid reactor (AHR) combining sludge blanket in the lower part and filter in the upper part under varying organic loading rates (OLRs) in order to study biodegradation of olive mill effluent (OME). For this purpose, some parameters, such as total phenols, effluent chemical oxygen demand (COD), suspended solids (SS), volatile fatty acids (VFAs), and pH in the influent and effluent, and removal efficiencies for those parameters (except pH) were continuously monitored throughout the experimental period of 477 days. Eleven different organic loadings between 0.45 and 32 kg COD m−3 day−1 were imposed by either varying influent COD or hydraulic retention time (HRT). The results demonstrated that the AHR reactor could tolerate high influent COD concentrations. Removal efficiencies for the studied pollution parameters were found to be as follows: COD, 50–94%; total phenol, 39–80%; color, 0–54%; and suspended solids, 19–87%. The levels of VFAs in the effluent, which was principally acetate, butyrate, iso-butyrate, and propionate, varied between 10 and 2005 mg l−1 depending upon OLRs. A COD removal efficiency of 90% could be achieved as long as OLR is kept at a level of less than 10 kg COD m−3 day−1. However, a secondary treatment unit for polishing purposes is necessary to comply with receiving media discharge standards.  相似文献   

13.
Two anaerobic filters, one mesophilic (35 degrees C) and one thermophilic (55 degrees C), were operated with a papermill wastewater at a series of organic loadings. The hydraulic retention time (HRT) ranged from 6 to 24 h with organic loading rates (OLR) 1.07-12.25 g/l per day. At loading rates up to 8.4 g COD/l d, there was no difference in terms of the removal of soluble COD (SCOD) and gas production. At the higher organic loading rate, the SCOD removal performance of thermophilic digester was slightly better compare to mesophilic digester. Similar trend was also observed in terms of the daily methane production. The stability of thermophilic digester was also better than mesophilic digester particularly for the higher organic loadings. Volatile fatty acid accumulation was observed in the effluent of the mesophilic filter at the higher organic loading rates. The Stover-Kincannon model was applied to both digesters and it was found that model was applicable to both digesters for papermill wastewater. K(B) and U(max) constants from the Stover-Kincannon model were also derived.  相似文献   

14.
Continuous flow sand column bioreactor experiments were conducted to investigate the effect of 2,4-dinitrotoluene (DNT) concentration (i.e. DNT loading rate) and influent dissolved oxygen (DO) concentration on aerobic biodegradation of DNT by wild type (DNT) and recombinant (YV1) Burkholderia sp., the latter containing plasmid pSC160 which carries the gene (vgb) encoding the hemoglobin (VHb) from the bacterium Vitreoscilla. The experiments were conducted in two continuous flow packed bed sand column bioreactors, one growing the wild type strain and the other growing YV1. Under oxygen-rich feed conditions (6.8 mg DO/L in the feed) with an influent DNT concentration of 99.6 mg/L (DNT loading rate approximately = 9.2 mg/m2/day), the effluent DNT concentration from the wild type bioreactor reached 0.7 mg DNT/L in 40 days whereas it was less than 0.2 mg DNT/L for the YV1 bioreactor in about 25 days. When influent DNT concentration was increased to 214 mg/L (DNT loading rate approximately = 20.3 mg/m2/day) while maintaining the same influent DO level of 6.8 mg/L, the effluent DNT concentration increased to about 5 mg/L for the wild type bioreactor whereas it was maintained at less than 0.2 mg/L for the YV1 bioreactor. Additionally, when influent DO was reduced from 6.8 mg/L to 3.1 mg/L while the influent DNT concentration remained at 214 mg/L, the effluent DNT concentration increased to more than 20 mg/L for the wild type bioreactor but up to only 1.7 mg/L for the YV1 bioreactor. A subsequent increase of influent DO back to 6.6 mg/L reduced the effluent DNT concentration to about 5 mg/L for the wild type bioreactor and to 0.10-0.19 mg/L for the YV1 bioreactor. These results confirm the utility of vgb technology to enhance biodegradation of aromatic compounds under hypoxic conditions and also that this enhancement can be maintained over extended periods of time as evidenced by plasmid stability in Burkholderia YV1.  相似文献   

15.
The primary objective of this study was to evaluate the effects of the organic loading rate on the performance of an up-flow anaerobic sludge blanket (UASB) reactor treating olive mill effluent (OME), based on the following indicators: (i) chemical oxygen demand (COD) removal efficiency; and (ii) effluent variability (phenol, suspended solids, volatile fatty acids, and pH stability). The UASB reactor was operated under different operational conditions (OLRs between 0.45 and 32 kg COD/m3·day) for 477 days. The results demonstrated that the UASB reactor could tolerate high influent COD concentrations. Removal efficiencies for the studied pollution parameters were found to be as follows: COD, 47∼92%; total phenol, 34∼75%; color, 6∼46%; suspended solids, 34∼76%. The levels of VFAs in the influent varied between 310 and 1,750 mg/L. Our measurements of the VFA levels indicated that some of the effluent COD could be attributed to VFAs (principally acetate, butyrate, iso-butyrate, and propionate) in the effluent, which occurred at levels between 345 and 2,420 mg/L. As the OLRs were increased, more VFAs were measured in the effluent. A COD removal efficiency of 90% could be achieved as long as OLR was kept at a level of less than 10 kg COD/m3·day. However, a secondary treatment unit for polishing purposes is necessary to comply with discharge standards.  相似文献   

16.
The composite filler micro-embedded with Pseudomonas putida (P. putida) was prepared and the biodegradation performance of the filler was evaluated in a biofilter. Five phases were set up to evaluate the performance of the biofilter under different toluene inlet loadings and transient shock loadings. In particular, the microbial community structure in the biofilms and fillers was measured by sequence analysis of the 16S rRNA gene. The results show that the biofilter packed with the composite fillers was suitable for the biodegradation of toluene. The biofilter could start up quickly with high removal efficiency (RE), and remain above 90 % RE when the empty bed residence time (EBRT) was 18 s and the inlet loading rates were not higher than 41.4 g/(m3·h). Moreover, the biofilter could tolerate substantial transient shock loadings. The high removal efficiency and elimination capacity contributed to rich bacterial communities for the efficient degradation of toluene. The dominant microbial communities at the phylum level were mainly Firmicutes, Actinobacteria and Proteobacteria. It is noteworthy that the abundance of Bacteroidetes at phylum level and Chungangia and Stenotrophomonas at genus level increased significantly during the re-start period.  相似文献   

17.
The aim of this paper is to investigate the performance and optimization of an biological nitrogen removal process enhanced by the anoxic/oxic four stages step-feeding process under sufficient/insufficient influent carbon source. The concept of influent flow distribution ratio (λ) was introduced according to the performance of the step-feed process for inflow splitting and volume distribution. Under the condition of sufficient carbon, the uniform influent flow distribution ratio was proposed from the standpoint of which is easy for process control, operation optimization and management. Under the condition of different influent C/N ratios, the optimal influent flow distribution ratios (λopt) were determined, by trial-and-error method. The results showed that more than 95.81% of the total nitrogen removal efficiency could be achieved by step-feeding process with a fixed influent C/N ratio. A model was introduced to derive the relationships of total nitrogen removal efficiency with λ and influent C/N ratio. When the influent carbon source was insufficient, however, the λopt between two adjacent stages should not be uniform. The results also showed that the four-stage step-feeding process with λopt of 2.0:2.1:2.5:3.4 could significantly improve the total nitrogen removal efficiency. The results obtained in this study will help to optimize the design and the operation of BNR systems.  相似文献   

18.
探究了3种水力负荷(HLR)下三级串联垂直潜流人工湿地(T-VFCWs)对农村生活污水的处理效果,并解析了系统中的氮素转化机制。结果表明: 当系统HLR由0.10增至0.20 m3·m-2·d-1时,T-VFCWs始终保持着对农村生活污水高效的处理效果,系统出水水质满足《城镇污水处理厂污染物排放标准》(GB 18918—2002)一级A标准。T-VFCWs中顺次连接的3个VFCW单元(标记为V-1、V-2和V-3)在限氧环境下因其进水水质的差异可形成各自不同的氮素转化途径,并通过协同作用实现系统的高效脱氮。当T-VFCWs在试验期间连续运行时,V-1、V-2和V-3中主要的脱氮途径分别为短程硝化/反硝化作用、基于亚硝化的全程自养脱氮(CANON)作用和反硝化作用,上述3单元对进水中总氮(TN)和NH4+-N去除的贡献率分别为(51.3±4.4)%和(63.7±2.6)%、(30.9±4.8)%和(35.5±4.5)%、(17.8±5.0)%和(0.8±0.1)%。该研究可为组合式人工湿地的研发及工程化应用提供科学依据和技术支撑。  相似文献   

19.
《Process Biochemistry》2007,42(4):620-626
Experiments have been performed to investigate the nitrogen removal performance in a novel combined biofilm reactor using synthetic wastewater. In the reactor, one cubic box was separated by two baffles into three zones: aerobic zone, buffering zone and anoxic zone. Nitrification and denitrification were supposed to be mainly accomplished in the aerobic and anoxic zones, respectively. When the influent total nitrogen (TN) and organic carbon loadings were averaged at 0.093 and 0.40 kg/m3/d, 84% TN removal efficiency was achieved by adjusting the aeration rate and the configuration of the reactor. Continuous experimental results demonstrated that NH3-N removal efficiency increased by adjusting the clapboards of the reactor at a certain aeration rate. Energy produced by aeration was used for liquid recycle, so TN could be more efficiently removed at lower cost in this reactor.  相似文献   

20.
The effect of effluent recirculation on perchlorate reduction in a nominally plug-flow fixed biofilm reactor was studied in two cases: influent concentrations of 10 and 400 microg/L at low hydraulic loading rates (1.9 and 37.5 m(3)/m(2)/day without and with recirculation, respectively) and after a step increase in perchlorate concentration to 1,000 microg/L at the higher hydraulic loading rate (5 and 100 m(3)/m(2)/day without and with recirculation, respectively). Complete perchlorate reduction was sustained for influent concentrations of 400 and 10 microg/L in both flow regimes at the lower hydraulic loading rates. Reactor tracer profiles showed that biofilm diffusion had a more significant effect on mass transfer in the plug flow reactor compared with recirculation. The recirculation bioreactor acclimated more rapidly to increased hydraulic and perchlorate mass loading rates with significantly lower effluent perchlorate compared to the plug flow reactor: 16 microg/L versus 46 microg/L, respectively, although complete perchlorate removal was not achieved in either flow regime after 21 days acclimation to the higher loading. Total biofilm mass was more uniformly distributed in the recirculation reactor which may have contributed to better performance under increased perchlorate loading.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号