首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Conventional methods for Salmonella detection in foods can require up to 6 and at least 4 days. We have observed that the total analysis time can be reduced to 48 h by using Salmosyst broth as a liquid medium for both preenrichment and selective enrichment and Rambach agar (RA), a new selective plate medium. In samples of artificially contaminated ground beef Salmonella enteritidis was detected at a concentration of 0.4 CFU/g (10 CFU/25 g) by both a conventional method and the new method. Of 519 samples of foods for sale, 38 were Salmonella positive by both methods while 471 were negative. Nine samples which were negative by the conventional method were positive by the Salmosyst-RA method, while one sample positive by the first method was negative by the last. Therefore, the Salmosyst-RA method showed 97.9% sensitivity compared with the 81.2% sensitivity of the conventional method. The new method was also highly specific (98% specificity) in presumptive identification of Salmonella colonies. Furthermore, a 6-h preenrichment in Salmosyst broth has been proved sufficient for the repair of heat-injured Salmonella cells and for subsequent recovery by selective enrichment. In conclusion, the Salmosyst-RA method shows several advantages over both conventional and rapid noncultural methods: (i) only two media are required instead of the five media for conventional methods; (ii) in real time it is comparable to other rapid noncultural methods, which require 30 to 31 h; (iii) it is highly sensitive and specific; and (iv) it allows the isolation of Salmonella strains which can be characterized by appropriate phenotypic and genotypic typing methods for epidemiological investigations.  相似文献   

2.
The necessity of developing a quick, sensitive, and reliable test for Salmonella in nonfat dry milk (NDM) is evident from the recent tracing of Salmonella outbreaks to this product. Normally, coagulation of casein occurs when assaying NDM under regular cultural conditions, raising the possibility of trapped bacteria. After 20 hr of incubation of NDM in preenrichment lactose broth, enrichment was achieved by using Selenite-Cystine Broth. Smears from the enrichment broth were examined by the fluorescent-antibody technique (FAT) with a commercially available polyvalent O globulin conjugated with fluorescein. Standard cultural methods (SCM) were performed for comparison with FAT. Sensitivity of FAT was definitely improved by the use of trypsin. Casein coagulation of NDM can be avoided by addition of trypsin to samples during initial preenrichment in lactose broth. Samples containing approximately one Salmonella per 10 g were easily detected by FAT with the use of trypsin-treated samples. The method required only 42 hr to complete. Additionally, the use of trypsin enhanced recovery of Salmonella by use of SCM, as evidenced by alteration in the observed coliform to Salmonella ratios.  相似文献   

3.
AIMS: The aim of this study was to compare the real-time iQ-Check Salmonella kit (Bio-Rad) with the immunocapture assay RapidCheck Salmonella method, and a conventional culture method (FSIS, USDA) in detecting Salmonella in naturally contaminated turkey meat products. This study was also designed to determine if a selective enrichment step might improve the real-time detection of Salmonella. METHODS AND RESULTS: Using the culture method, Salmonella was recovered from 49 out of 99 retail turkey meat samples collected. RapidCheck failed to detect 11 Salmonella samples that were positive by the culture method. The iQ-Check real-time PCR also failed to detect three samples that were positive by the culture method. However, when carried out after a selective enrichment step, the iQ-Check real-time PCR detected all 49 Salmonella samples recovered by the culture method. The iQ-Check real-time PCR detected the presence of Salmonella in some samples that were not recovered by the culture method. CONCLUSIONS: Adding a selective enrichment step to the iQ-Check real-time PCR improves the detection of Salmonella in naturally contaminated turkey meat samples. SIGNIFICANCE AND IMPACT OF THE STUDY: The iQ-Check Salmonella real-time PCR can be used as a rapid method to monitor Salmonella in turkey meat, together with conventional culture methodology.  相似文献   

4.
An indirect fluorescent-antibody (IFA) technique, which employed adsorbed Behring polyvalent I O antiserum, was used to detect Salmonella spp. in environmental water systems. The IFA method used in this study detected 95% of Salmonella serotypes encountered in human infections in France, with a sensitivity threshold of 7.5 x 10(3) bacteria per ml of wastewater. Specificity was assessed by testing IFA against Salmonella-free seawater and a variety of bacteria other than Salmonella spp. When used to examine raw and chlorinated wastewater over a 2-month period, the IFA method was successful in detecting Salmonella spp. in all 12 of the samples examined, with total numbers determined to be 4.5 x 10(5) to 3.3 x 10(7) salmonellae per 100 ml. In comparison, for the same samples, enumeration by culture, using the most-probable-number technique, was effective in detecting Salmonella spp. in only four of eight raw-water samples and one of four chlorinated water samples tested. Three samples were further tested by using the direct viable count procedure combined with IFA and results showed that 5 to 31.5% of the Salmonella spp. enumerated by this method in chlorinated water were substrate responsive.  相似文献   

5.
An indirect fluorescent-antibody (IFA) technique, which employed adsorbed Behring polyvalent I O antiserum, was used to detect Salmonella spp. in environmental water systems. The IFA method used in this study detected 95% of Salmonella serotypes encountered in human infections in France, with a sensitivity threshold of 7.5 x 10(3) bacteria per ml of wastewater. Specificity was assessed by testing IFA against Salmonella-free seawater and a variety of bacteria other than Salmonella spp. When used to examine raw and chlorinated wastewater over a 2-month period, the IFA method was successful in detecting Salmonella spp. in all 12 of the samples examined, with total numbers determined to be 4.5 x 10(5) to 3.3 x 10(7) salmonellae per 100 ml. In comparison, for the same samples, enumeration by culture, using the most-probable-number technique, was effective in detecting Salmonella spp. in only four of eight raw-water samples and one of four chlorinated water samples tested. Three samples were further tested by using the direct viable count procedure combined with IFA and results showed that 5 to 31.5% of the Salmonella spp. enumerated by this method in chlorinated water were substrate responsive.  相似文献   

6.
Rapid screening of poultry houses for contamination is critical for Salmonella control. Use of air filter sampling has great potential for efficient and reliable monitoring of Salmonella spp., as it could represent an entire poultry house and solve sample-size problems. Two sampling methods (litter and air filter) were compared for detection in four chicken pens inoculated with a S. typhimurium antibiotic resistant strain. Salmonella levels in both litter and air filter samples were determined by PCR amplification and by conventional enrichment. Although amplified DNA was not directly detected, amplified DNA could be detected using a dual probe hybridization sensor. The ratio of the positive samples to total samples determined by gene amplification was much lower than that obtained by conventional enrichments (29/128 versus 102/128 samples). However, the ratio obtained by gene amplification with air filter samples was greater than that with litter samples (26/64 versus 3/64). These results demonstrate that the air filter sampling method is an alternative method of Salmonella detection in poultry house using PCR gene amplification protocol. Journal of Industrial Microbiology & Biotechnology (2000) 24, 379–382. Received 12 August 1999/ Accepted in revised form 17 February 2000  相似文献   

7.
Salmonellosis is a cyclic problem in the food industry, to which animal feed has been contributory. Current conventional methods of Salmonella spp. detection require 96 h for detection and confirmation. With modern and just-in-time production schedules, a 96-h hold represents a significant expense in storage and decontamination. The commercially available assay, 'BAX for Screening/Salmonella' (BAX), is based on the principle of the polymerase chain reaction and may represent a significant decrease in assay time. Seven fresh feed formulations, two fresh feed ingredients, seven stored feeds and two stored feed ingredients were artificially contaminated with a primary poultry isolate of Salmonella typhimurium and analysed by conventional and BAX methodology. The results of BAX agreed with conventional plating results for 16 of 18 samples spiked with 1200 cfu 10 g(-1) of feed and 13 of 18 samples spiked with 40 cfu 10 g(-1) of feed. Indigenous Salmonella spp. were detected in five of eight samples of poultry diets by conventional methods. With BAX, Salmonella spp. could not be detected in any of the samples after only 7 h of enrichment but could be detected in two dietary samples after 13 h of enrichment and four dietary samples after 24 h of enrichment. Specific sequences of salmonella DNA that were extracted from poultry diets could be detected with BAX.  相似文献   

8.
A multiplex PCR assay was devised and compared with standard conventional methods for quality evaluation of pharmaceutical raw materials and finished products with low levels of microbial contamination. Samples which were artificially contaminated with <10 colony forming units of Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, and Salmonella species and possibly contaminated samples were incubated for 16 h with different enrichment media. Primers that deduce 559 bp fragment of the 16S rRNA gene was employed in amplifying E. coli species, similarly invasion protein gene with 275 bp fragment size was used as target for detecting Salmonella spp., in case of S. aureus a 461 bp amplicon from m-RNA nuclease gene, and an 709 bp fragment from oprL gene was used for amplifying P. aeruginosa. The detection limits for artificially contaminants by multiplex PCR was 1 CFU/g, where as in case of conventional method the detection limit was >2 CFU/g. Similarly, when tested with possibly contaminated samples, 35% were detected for E. coli, Salmonella spp., S. aureus and P. aeruginosa species with multiplex PCR, while only 21% were detected with standard conventional microbial methods. Multiplex PCR assay provides sensitive and reliable results and allows for the cost-effective detection of all four bacterial pathogens in single reaction tube.  相似文献   

9.
AIMS: To compare the BAX system, the Tecra Unique Salmonella test, and a conventional culture method for the detection of Salmonella in various foods. METHODS AND RESULTS: Ready-to-eat and raw foods were inoculated with Salmonella serotype Typhimurium, Salmonella serotype Enteritidis, Salmonella serotype Typhi, or Salmonella serotype Derby. Incubated pre-enrichment cultures were examined using the BAX system, the Tecra Unique Salmonella test, and a conventional culture method. Salmonella could be detected in all ready-to-eat food samples inoculated with S. Typhimurium, S. Enteritidis, or S. Derby, with any of the three test methods. However, false negatives were obtained with the Tecra test and the culture method when samples with higher background flora were inoculated with S. Typhi. Sensitivity test results suggested the two rapid tests performed as well as the culture method in the detection of 10(1) CFU of S. Typhimurium in 25-g cooked or raw food. CONCLUSIONS: The BAX system and the Tecra Unique Salmonella test demonstrated results comparable with those of the culture method in the detection of Salmonella serotypes used except S. Typhi. SIGNIFICANCE AND IMPACT OF THE STUDY: This is the first evaluation of the BAX system, the Tecra Unique Salmonella test, and a culture method in the detection of Salmonella in a variety of western and oriental foods.  相似文献   

10.
A rapid hydrophobic grid-membrane filter (HGMF) method was developed and compared with the Health Protection Branch cultural method for the detection of Salmonella spp. in 798 spiked samples and 265 naturally contaminated samples of food. With the HGMF method, Salmonella spp. were isolated from 618 of the spiked samples and 190 of the naturally contaminated samples. The conventional method recovered Salmonella spp. from 622 spiked samples and 204 unspiked samples. The isolation rates from Salmonella-positive samples for the two methods were not significantly different (94.6% overall for the HGMF method and 96.7% for the conventional approach), but the HGMF results were available in only 2 to 3 days after sample receipt compared with 3 to 4 days by the conventional method.  相似文献   

11.
基因芯片技术检测3种食源性致病微生物方法的建立   总被引:5,自引:0,他引:5  
建立一种运用多重PCR和基因芯片技术检测和鉴定志贺氏菌、沙门氏菌、大肠杆菌O157的方法, 为3种食源性致病菌的快速检测和鉴定提供了准确、快速、灵敏的方法。分别选取编码志贺氏菌侵袭性质粒抗原H基因(ipaH)、沙门氏菌肠毒素(stn)基因和致泻性大肠杆菌O157志贺样毒素(slt)基因设计引物和探针, 进行三重PCR扩增, 产物与含特异性探针的芯片杂交。对7种细菌共26株菌进行芯片检测, 仅3种菌得到阳性扩增结果, 证明此方法具有很高的特异性。3种致病菌基因组DNA和细菌纯培养物的检测灵敏度约为8 pg。对模拟食品样品进行直接检测, 结果与常规细菌学培养结果一致, 检测限为50 CFU/mL。结果表明:所建立的基因芯片检测方法特异性好, 灵敏度高, 为食源性致病菌的检测提供了理想手段, 有良好的应用前景。  相似文献   

12.
Three rapid methods, an impedance method (Malthus 2000 Analyzer), a colorimetric DNA hybridization method (Gene-Trak) and a post-enrichment enzyme-linked immunosorbent assay (Salmonella-Tek) were compared with conventional culture for the detection of Salmonella in poultry feeds, and in fluff and dust samples from poultry housing. The percentage positive samples for Salmonella by each of the methods were 25.5% for conventional culture, 38.4% for the Malthus, 28.9% for the Gene-Trak and 28.5% for the Salmonella-Tek. By any method 60/153 (39.2%) of the samples tested were positive on confirmed culture.  相似文献   

13.
14.
In this trial an in-house conventional method was compared with the MSRV method for Salmonella detection. Various high and low moisture foodstuffs (121 and 116 samples respectively), some either artificially or naturally contaminated, were examined.
Eleven different serotypes of Salmonella were used to inoculate samples and no significant difference was observed in the sensitivity of any of the media used. Significantly lower numbers of false-positive results were obtained with the MSRV agar when compared to MLCB agar.
This work suggests that the MSRV method as used here, could be used to replace conventional Salmonella detection methods for both high and low moisture foodstuffs.  相似文献   

15.
Direct detection of Salmonella spp. in estuaries by using a DNA probe   总被引:2,自引:0,他引:2  
A method for direct detection of Salmonella spp. in water was developed by using a commercially available DNA probe. Particulate DNA was extracted from 500- to 1,500-ml water samples collected from New York Harbor and Chesapeake Bay and used as a substrate for a salmonella-specific DNA probe in dot blot assays. The method detected salmonellae in water samples from 12 of 16 sites, including 6 sites where salmonellae could not be cultured. The specificity of the probe was evaluated, and cross-hybridization, although negligible, was used to set detection limits for the assay. Salmonella DNA bound the probe quantitatively, and from these results Salmonella DNA in the total particulate DNA in environmental samples could be estimated. The data obtained in this study indicate that Salmonella spp. often are not detected in water samples by culture methods, even when they are present in significant numbers.  相似文献   

16.
A method for direct detection of Salmonella spp. in water was developed by using a commercially available DNA probe. Particulate DNA was extracted from 500- to 1,500-ml water samples collected from New York Harbor and Chesapeake Bay and used as a substrate for a salmonella-specific DNA probe in dot blot assays. The method detected salmonellae in water samples from 12 of 16 sites, including 6 sites where salmonellae could not be cultured. The specificity of the probe was evaluated, and cross-hybridization, although negligible, was used to set detection limits for the assay. Salmonella DNA bound the probe quantitatively, and from these results Salmonella DNA in the total particulate DNA in environmental samples could be estimated. The data obtained in this study indicate that Salmonella spp. often are not detected in water samples by culture methods, even when they are present in significant numbers.  相似文献   

17.
An enzyme-linked immunosorbent assay (ELISA) for detection of salmonellae was developed and evaluated by using artificially contaminated specimens of poultry feed, feces, litter, or carcass rinsings, and naturally contaminated water samples. Specimens containing salmonellae of serogroups B or C2 inhibited the binding of polyvalent anti-O serum to microtiter plate wells coated with lipopolysaccharide of Salmonella typhimurium (serogroup B) or Salmonella albany (serogroup C2), respectively. Treatment of specimens with Rhozyme 41 (a protease) inhibited nonspecific reactions. The ELISA detected 106 of 111 culture-positive specimens contaminated with salmonellae of serogroups B or C2. Nineteen of 20 specimens containing salmonellae of serogroup C1 and all of 36 culture-negative specimens were ELISA negative. All seven water samples that contained salmonellae of serogroups B or C2, including three that were culture positive only after delayed secondary enrichment, were ELISA positive. Seven of the nine water samples that contained salmonellae of other serogroups, and all 38 culture-negative samples, were ELISA negative. The ELISA was simple to perform, produced results in 48 h, and was more economical than culture methods.  相似文献   

18.
Identification of individuals shedding Salmonella enterica serovar Typhi in stool is imperative during clinical trial safety evaluations. Recovery of live attenuated S. Typhi vaccine strains can be difficult because the mutations necessary for safety in humans often compromise survival in stringent selective enrichment media. RapidChek? SELECT? Salmonella is a highly sensitive detection method for S. enterica species which utilizes a bacteriophage cocktail designed to reduce the growth of competitor microbes in mildly selective enrichment medium. Detection of Salmonella is enhanced by means of a Salmonella-specific antibody strip targeted to lipopolysaccharide. The RapidChek? SELECT? Salmonella method was compared to conventional enrichment and plating methods to determine the most sensitive method for detecting attenuated S. Typhi strains in human stool samples. Although traditional enrichment strategies were more sensitive to the presence of wild-type S. Typhi, RapidChek? SELECT? Salmonella was superior at detecting attenuated strains of S. Typhi. Strains containing a wide variety of attenuating mutations were detected with equal sensitivity as the wild type by RapidChek? SELECT? Salmonella. The presence of Vi capsule or mutations which affected O-antigen synthesis (Δpmi, ΔgalE) did not decrease the sensitivity of the RapidChek? SELECT? Salmonella assay.  相似文献   

19.
Four rapid methods for detection of Salmonella, (i) the conventional fluorescent-antibody (FA) technique, (ii) a rapid direct FA technique, (iii) microcolony FA, and (iv) enrichment serology (ES), were compared with conventional cultural procedures. A total of 347 subsamples representing 16 different food prototypes, alleged to be naturally contaminated with Salmonella, were analyzed. From these samples, 52 were found to contain Salmonella by cultural methods. Conventional FA identified all 52 culturally positive samples, ES identified 51, microcolony FA identified 48, and the rapid FA method identified 34. The number of false-positive samples for each procedure was: ES-selenite, 7; tetrathionate, 8; rapid FA, 26; microcolony FA, 33; conventional FA-selenite, 27; tetrathionate, 26. Tetrathionate enrichment was found to be superior to selenite for Salmonella recovery from most foods, but the concurrent use of both media allowed maximum recovery.  相似文献   

20.
An enzyme-linked immunosorbent assay (ELISA) for detection of salmonellae was developed and evaluated by using artificially contaminated specimens of poultry feed, feces, litter, or carcass rinsings, and naturally contaminated water samples. Specimens containing salmonellae of serogroups B or C2 inhibited the binding of polyvalent anti-O serum to microtiter plate wells coated with lipopolysaccharide of Salmonella typhimurium (serogroup B) or Salmonella albany (serogroup C2), respectively. Treatment of specimens with Rhozyme 41 (a protease) inhibited nonspecific reactions. The ELISA detected 106 of 111 culture-positive specimens contaminated with salmonellae of serogroups B or C2. Nineteen of 20 specimens containing salmonellae of serogroup C1 and all of 36 culture-negative specimens were ELISA negative. All seven water samples that contained salmonellae of serogroups B or C2, including three that were culture positive only after delayed secondary enrichment, were ELISA positive. Seven of the nine water samples that contained salmonellae of other serogroups, and all 38 culture-negative samples, were ELISA negative. The ELISA was simple to perform, produced results in 48 h, and was more economical than culture methods.  相似文献   