首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 30 毫秒
1.
Nosocomial Legionnaires disease can be acquired by exposure to the organism from the hospital water distribution system. As a result, many hospitals have instituted eradication procedures, including hypercholorination and thermal eradication. We compared the efficacy of ozonation, UV light, hyperchlorination, and heat eradication using a model plumbing system constructed of copper piping, brass spigots, Plexiglas reservoir, electric hot water tank, and a pump. Legionella pneumophila was added to the system at 10(7) CFU/ml. Each method was tested under three conditions; (i) nonturbid water at 25 degrees C, (ii) turbid water at 25 degrees C, and (iii) nonturbid water at 43 degrees C. UV light and heat killed L. pneumophila most rapidly and required minimal maintenance. Both UV light and heat (60 degrees C) produced a 5 log kill in less than 1 h. In contrast, both chlorine and ozone required 5 h of exposure to produce a 5 log decrease. Neither turbidity nor the higher temperature of 43 degrees C impaired the efficacy of any of the disinfectant methods. Surprisingly, higher temperature enhanced the disinfecting efficacy of chlorine. However, higher temperature accelerated the decomposition of the chlorine residual such that an additional 120% volume of chlorine was required. All four methods proved efficacious in eradicating L. pneumophila from a model plumbing system.  相似文献   

2.
Three Legionella pneumophila strains isolated from water samples and belonging to serogroups (sgs) 1, 6 and 9 were analysed for their capacity to colonise an experimental model simulating a domestic hot water distribution system. Ecological factors that could influence the persistence of the sgs such as intracellular life within protozoan hosts and bacterial interference by the production of antagonistic compounds were also studied. Viable counts of L. pneumophila increased both in the planktonic and in the sessile phases. Sg 6 showed a marked prevalence during the whole experiment and exhibited the highest host infection efficiency. Sg 1 was significantly less represented, but showed the highest capacity to reproduce in the protozoan hosts. Sg 9 was poorly represented and less adapted to intracellular life. Among the 14 bacteria constantly isolated in the system, five (35.7%) produced antagonistic substances against Legionella, with differences according to the bacterial strain and L. pneumophila sgs.  相似文献   

3.
Three Legionella pneumophila strains isolated from water samples and belonging to serogroups (sgs) 1, 6 and 9 were analysed for their capacity to colonise an experimental model simulating a domestic hot water distribution system. Ecological factors that could influence the persistence of the sgs such as intracellular life within protozoan hosts and bacterial interference by the production of antagonistic compounds were also studied. Viable counts of L. pneumophila increased both in the planktonic and in the sessile phases. Sg 6 showed a marked prevalence during the whole experiment and exhibited the highest host infection efficiency. Sg 1 was significantly less represented, but showed the highest capacity to reproduce in the protozoan hosts. Sg 9 was poorly represented and less adapted to intracellular life. Among the 14 bacteria constantly isolated in the system, five (35.7%) produced antagonistic substances against Legionella, with differences according to the bacterial strain and L. pneumophila sgs.  相似文献   

4.
The effect of ozonation of supply water for one wing of an unoccupied hospital building which had positive cultures for Legionella pneumophila from multiple potable water fixtures was studied in a prospective, controlled fashion. Mean ozone residual concentrations of 0.79 mg/liter eradicated L. pneumophila from the fixtures, but so did nonozonated water in the control wing fixtures. The efficacy of the nonozonated water was most probably due to a mechanical flushing effect and to an unexpected rise in the chlorine content of the supply water. Determination of the in vitro activity of ozone against L. pneumophila did not predict the efficacy of its eradication from water fixtures treated with ozone.  相似文献   

5.
AIMS: Stagnation is widely believed to predispose water systems to colonization by Legionella. A model plumbing system was constructed to determine the effect of flow regimes on the presence of Legionella within microbial biofilms. METHODS AND RESULTS: The plumbing model contained three parallel pipes where turbulent, laminar and stagnant flow regimes were established. Four sets of experiments were carried out with Reynolds number from 10,000 to 40,000 and from 355 to 2,000 in turbulent and laminar pipes, respectively. Legionella counts recovered from biofilm and planktonic water samples of the three sampling pipes were compared with to determine the effect of flow regime on the presence of Legionella. Significantly higher colony counts of Legionella were recovered from the biofilm of the pipe with turbulent flow compared with the pipe with laminar flow. The lowest counts were in the pipe with stagnant flow. CONCLUSIONS: We were unable to demonstrate that stagnant conditions promoted Legionella colonization. SIGNIFICANCE AND IMPACT OF THE STUDY: Plumbing modifications to remove areas of stagnation including deadlegs are widely recommended, but these modifications are tedious and expensive to perform. Controlled studies in large buildings are needed to validate this unproved hypothesis.  相似文献   

6.
Aims: The potential effect of in‐premise plumbing temperatures (24, 32, 37 and 41°C) on the growth of five different Legionella pneumophila strains within free‐living amoebae (Acanthamoeba polyphaga, Hartmannella vermiformis and Naegleria fowleri) was examined. Methods and Results: Compared with controls that actively fed on Escherichia coli prey, when Leg. pneumophila was used as prey, strains Lp02 and Bloomington‐2 increased in growth at 30, 32 and 37°C while strains Philadelphia‐1 and Chicago 2 did not grow at any temperature within A. polyphaga. Strains Lp02, Bloomington‐2 and Dallas 1E did not proliferate in the presence of H. vermiformis nor did strain Philadelphia‐1 in the presence of N. fowleri. Yet, strain Bloomington‐2 grew at all temperatures examined within N. fowleri, while strain Lp02 proliferated at all temperatures except 41°C. More intriguing, strain Chicago 2 only grew at 32°C within H. vermiformis and N. fowleri suggesting a limited temperature growth range for this strain. Conclusions: Identifying the presence of pathogenic legionellae may require the use of multiple host amoebae and incubation temperatures. Significance and Impact of the Study: Temperature conditions and species of amoeba host supported in drinking water appear to be important for the selection of human‐pathogenic legionellae and point to future research required to better understand Legionella ecology.  相似文献   

7.
Samples obtained from plumbing systems of hospitals, nonhospital institutions and homes were cultured for Legionella spp. by plating the samples directly on a selective medium. Swab samples were taken from the inner surfaces of faucet assemblies (aerators, spouts, and valve seats), showerheads, and shower pipes. Water and sediment were collected from the bottom of hot-water tanks. Legionella pneumophila serogroups 1, 5, and 6 were recovered from plumbing fixtures of the hospitals and nonhospital institutions and one of five homes. The legionellae (7 to 13,850 colony-forming units per ml) were also present in water and sediment from hot-water tanks maintained at 30 to 54 degrees C, but not in those maintained at 71 and 77 degrees C. Legionella micdadei was isolated from one tank. Thus legionellae are present in hot-water tanks which are maintained at warm temperatures or whose design results in warm temperatures at the bottom of the tanks. We hypothesize that hot-water tanks are a breeding site and a major source of L. pneumophila for the contamination of plumbing systems. The existence of these bacteria in the plumbing systems and tanks was not necessarily associated with disease. The extent of the hazard of this contamination needs to be delineated.  相似文献   

8.
Survival and growth of Legionella pneumophila in both biofilm and planktonic phases were determined with a two-stage model system. The model used filter-sterilized tap water as the sole source of nutrient to culture a naturally occurring mixed population of microorganisms including virulent L. pneumophila. At 20 degrees C, L. pneumophila accounted for a low proportion of biofilm flora on polybutylene and chlorinated polyvinyl chloride, but was absent from copper surfaces. The pathogen was most abundant on biofilms on plastics at 40 degrees C, where it accounted for up to 50% of the total biofilm flora. Copper surfaces were inhibitory to total biofouling and included only low numbers of L. pneumophila organisms. The pathogen was able to survive in biofilms on the surface of the plastic materials at 50 degrees C, but was absent from the copper surfaces at the same temperature. L. pneumophila could not be detected in the model system at 60 degrees C. In the presence of copper surfaces, biofilms forming on adjacent control glass surfaces were found to incorporate copper ions which subsequently inhibited colonization of their surfaces. This work suggests that the use of copper tubing in water systems may help to limit the colonization of water systems by L. pneumophila.  相似文献   

9.
Survival of Legionella pneumophila in a model hot water distribution system   总被引:3,自引:0,他引:3  
A virulent strain of Legionella pneumophila was inoculated into an enclosed system supplied with unsterilized water from a domestic hot water supply. Growth of bacteria was monitored over 10 weeks. An increase in the number of organisms other than legionellas occurred but few amoebae were observed and none could be cultured. Viable counts of L. pneumophila in the circulation fluid decreased slightly. However, particles of debris which accumulated in the apparatus and which were stained by the indirect fluorescent antibody technique were found to be almost totally composed of L. pneumophila. On dismantling the apparatus Legionella was isolated in moderately high numbers from several different types of surfaces, particularly natural rubber and silicone.  相似文献   

10.
An environmentally representative stagnant-water model was developed to monitor the growth dynamics of Legionella pneumophila. This model was evaluated for three distinct water treatments: untreated tap water, heat-treated tap water, and heat-treated tap water supplemented with Pseudomonas putida, a known biofilm-forming bacterium. Bringing heat-treated tap water after subsequent cooling into contact with a densely formed untreated biofilm was found to promote the number of L. pneumophila by 4 log units within the biofilm, while the use of untreated water only sustained the L. pneumophila levels. Subsequent colonization of the water phase by L. pneumophila was noticed in the heat-treated stagnant-water models, with concentrations as high as 1 x 10(10) mip gene copies L(-1) stagnant water. Denaturing gradient gel electrophoresis in combination with clustering analysis of the prokaryotic community in the water phase and in the biofilm phase suggests that the different water treatments induced different communities. Moreover, boosts of L. pneumophila arising from heat treatment of water were accompanied by shifts to a more diverse eukaryotic community. Stimulated growth of L. pneumophila after heating of the water may explain the rapid recolonization of L. pneumophila in water systems. These results highlight the need for additional or alternative measures to heat treatment of water in order to prevent or abate potential outbreaks of L. pneumophila.  相似文献   

11.
A model hot water distribution network was seeded with a virulent strain of Legionella pneumophila serotype 1. Ten weeks after inoculation, components of the system, which include aluminium discs, copper, stainless steel, silicone tubing, rubber and glass beads, were examined for colonization by L. pneumophila. The samples were stained with fluorescein-labelled antibodies to the strain and were examined with scanning electron microscopy. Colonization, which was accompanied by copious quantities of a slime-like debris, was heaviest on the rubber and least on the copper. Adherence to silicone tubing and stainless steel was observed.  相似文献   

12.
A model hot water distribution network was seeded with a virulent strain of Legionella pneumophila serotype 1. Ten weeks after inoculation, components of the system, which include aluminium discs, copper, stainless steel, silicone tubing, rubber and glass beads, were examined for colonization by L. pneumophila. The samples were stained with fluorescein-labelled antibodies to the strain and were examined with scanning electron microscopy. Colonization, which was accompanied by copious quantities of a slime-like debris, was heaviest on the rubber and least on the copper. Adherence to silicone tubing and stainless steel was observed.  相似文献   

13.
Legionella pneumophila is accounted for more than 80% of Legionella infection. However it is difficult to discriminate between the L. pneumophila and non-L. pneumophila species rapidly. In order to detect the Legionella spp. and distinguish L. pneumophila from Legionella spp., a real-time loop-mediated isothermal amplification (LAMP) platform that targets a specific sequence of the 16S rRNA gene was developed. LS-LAMP amplifies the fragment of the 16S rRNA gene to detect all species of Legionella genus. A specific sequence appears at the 16S rRNA gene of L. pneumophila, while non-L. pneumophila strains have a variable sequence in this site, which can be recognized by the primer of LP-LAMP. In the present study, 61 reference strains were used for the method verification. We found that the specificity was 100% for both LS-LAMP and LP-LAMP, and the sensitivity of LAMP assay for L. pneumophila detection was between 52 and 5.2 copies per reaction. In the environmental water samples detection, a total of 107 water samples were identified by the method. The culture and serological test were used as reference methods. The specificity of LS-LAMP and LP-LAMP for the samples detection were 91.59% (98/107) and 93.33% (56/60), respectively. The sensitivity of LS-LAMP and LP-LAMP were 100% (51/51) and 100% (18/18). The results suggest that real-time LAMP, as a new assay, provides a specific and sensitive method for rapid detection and differentiation of Legionella spp. and L. pneumophila and should be utilized to test environmental water samples for increased rates of detection.  相似文献   

14.
The stagnation of water in two of four hospital hot-water storage tanks found to contain Legionella pneumophila was reduced by keeping the two tanks continually on-line for 1 year. L. pneumophila colony counts in these two tanks fell quickly to low levels, whereas the organisms persisted in the two tanks that were not in use. L. pneumophila continued to be isolated from 50 to 100% of the hospital showerheads which were sampled during this period. We also examined aerators and other hospital faucet fixtures which obstruct water flow. L. pneumophila was isolated from 22 of 30 faucet aerators and 2 of 16 vacuum breakers but not from 26 nonobstructed faucets or 6 backflow preventers. Over a 7-month period, after nine faucet aerators were sterilized, 10 of 60 surveillance cultures revealed L. pneumophila, despite the inability to isolate the organism from the potable-water tanks in use. These data suggest that prevention of stagnation in hot-water tanks may be effective in reducing L. pneumophila concentrations in potable-water systems serving high-risk populations. We have also shown that faucet aerators, by providing a surface for L. pneumophila to colonize, can become secondary reservoirs for the organism in hospital plumbing.  相似文献   

15.
16.
Water disinfection systems utilizing electrolytically generated copper and silver ions (200 and 20, 400 and 40, or 800 and 80 micrograms/liter) and low levels of free chlorine (0.1 to 0.4 mg/liter) were evaluated at room (21 to 23 degrees C) and elevated (39 to 40 degrees C) temperatures in filtered well water (pH 7.3) for their efficacy in inactivating Legionella pneumophila (ATCC 33155). At room temperature, a contact time of at least 24 h was necessary for copper and silver (400 and 40 micrograms/liter) to achieve a 3-log10 reduction in bacterial numbers. As the copper and silver concentration increased to 800 and 80 micrograms/liter, the inactivation rate significantly (P less than or equal to 0.05) increased from K = 2.87 x 10(-3) to K = 7.50 x 10(-3) (log10 reduction per minute). In water systems with and without copper and silver (400 and 40 micrograms/liter), the inactivation rates significantly increased as the free chlorine concentration increased from 0.1 mg/liter (K = 0.397 log10 reduction per min) to 0.4 mg/liter (K = 1.047 log10 reduction per min). Compared to room temperature, no significant differences were observed when 0.2 mg of free chlorine per liter with and without 400 and 40 micrograms of copper and silver per liter was tested at 39 to 40 degrees C. All disinfection systems, regardless of temperature or free chlorine concentration, showed increase inactivation rates when 400 and 40 micrograms of copper and silver per liter was added; however, this trend was significant only at 0.4 mg of free chlorine per liter.  相似文献   

17.
The conjugative properties of an indigenous 85 MDa plasmid (designated pCH1) from Legionella pneumophila were studied. To determine if pCH1 was transmissible by conjugation, mating experiments were performed between legionellae that harboured pCH1 and several plasmid-less recipients. Plasmid transfer was monitored by colony hybridization, using a cloned 21.0 kb SalI restriction fragment from pCH1 as a probe. The results from these experiments showed that pCH1 could be conjugatively transferred into several strains of L. pneumophila serogroup 1 but not into strain Bloomington-2 (serogroup 3) or Escherichia coli. Southern hybridization experiments in which pCH1 DNA was used as a probe showed that pCH1 does not share homology with other indigenous L. pneumophila plasmids. There was no detectable DNA homology between pCH1 and L. pneumophila chromosomal DNA. Additional mating experiments revealed that pCH1 was unable to mobilize the L. pneumophila chromosome. The conjugative transfer of pCH1 into plasmid-less avirulent or virulent serogroup 1 strains did not alter the intracellular growth characteristics of these strains in U937 cells, a human-monocyte-like cell line, or in the amoeba Hartmannella vermiformis. These results suggest that pCH1 does not contribute to the ability of L. pneumophila to enter or grow within eukaryotic cells.  相似文献   

18.
19.
A sensitive and specific method has been developed to enumerate viable L. pneumophila and other Legionella spp. in water by epifluorescence microscopy in a short period of time (a few hours). This method allows the quantification of L. pneumophila or other Legionella spp. as well as the discrimination between viable and nonviable Legionella. It simultaneously combines the specific detection of Legionella cells using antibodies and a bacterial viability marker (ChemChrome V6), the enumeration being achieved by epifluorescence microscopy. The performance of this immunological double-staining (IDS) method was investigated in 38 natural filterable water samples from different aquatic sources, and the viable Legionella counts were compared with those obtained by the standard culture method. The recovery rate of the IDS method is similar to, or higher than, that of the conventional culture method. Under our experimental conditions, the limit of detection of the IDS method was <176 Legionella cells per liter. The examination of several samples in duplicates for the presence of L. pneumophila and other Legionella spp. indicated that the IDS method exhibits an excellent intralaboratory reproducibility, better than that of the standard culture method. This immunological approach allows rapid measurements in emergency situations, such as monitoring the efficacy of disinfection shock treatments. Although its field of application is as yet limited to filterable waters, the double-staining method may be an interesting alternative (not equivalent) to the conventional standard culture methods for enumerating viable Legionella when rapid detection is required.  相似文献   

20.
A sensitive and specific method has been developed to enumerate viable L. pneumophila and other Legionella spp. in water by epifluorescence microscopy in a short period of time (a few hours). This method allows the quantification of L. pneumophila or other Legionella spp. as well as the discrimination between viable and nonviable Legionella. It simultaneously combines the specific detection of Legionella cells using antibodies and a bacterial viability marker (ChemChrome V6), the enumeration being achieved by epifluorescence microscopy. The performance of this immunological double-staining (IDS) method was investigated in 38 natural filterable water samples from different aquatic sources, and the viable Legionella counts were compared with those obtained by the standard culture method. The recovery rate of the IDS method is similar to, or higher than, that of the conventional culture method. Under our experimental conditions, the limit of detection of the IDS method was <176 Legionella cells per liter. The examination of several samples in duplicates for the presence of L. pneumophila and other Legionella spp. indicated that the IDS method exhibits an excellent intralaboratory reproducibility, better than that of the standard culture method. This immunological approach allows rapid measurements in emergency situations, such as monitoring the efficacy of disinfection shock treatments. Although its field of application is as yet limited to filterable waters, the double-staining method may be an interesting alternative (not equivalent) to the conventional standard culture methods for enumerating viable Legionella when rapid detection is required.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号