首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Recent advances in cholesterol biosensor   总被引:1,自引:0,他引:1  
Biosensors have recently gained much attention in the field of health care for the management of various important analytes in a biological system. The area achieved tremendous progress from the time when the first Clark electrode for measurement of glucose was realized. Advances in the biosensor design are appearing at a high rate as these devices play increasingly important roles in our daily lives. The increasing incidences of cardiovascular diseases and cardiac arrest are major cause of death of humans world over. One of the most important reasons is hypercholesterolemia, i.e. increased concentration of cholesterol in blood. Hence estimation of cholesterol level in blood is important in clinical applications. This review aims to highlight the recent advances in materials and techniques for cholesterol biosensor design and construction.  相似文献   

2.
Currently, the reliable detection and quantification of a multitude of different analytes is crucial in many applications and settings. Biosensors have revolutionised diagnostics for use in point-of-care testing (POC), the detection of food and environmental contaminants, biological warfare agents, illicit drugs and human/animal disease markers. Antibodies continue to play a pivotal role in many sensor devices due to their exquisite specificity for their cognate antigens. In this review current biosensor platforms employing antibodies for molecular recognition are briefly described. The use of molecular biological techniques for the generation and improvement of antibodies is critically examined. Such recombinant antibodies possess improved attributes for use in biosensor development in terms of design, stability, affinity and specificity.  相似文献   

3.
This paper records the efforts of a multi-disciplinary team of undergraduate students from Glasgow University to collectively design and carry out a 10 week project in Synthetic Biology as part of the international Genetic Engineered Machine competition (iGEM). The aim of the project was to design and build a self-powering electrochemical biosensor called ‘ElectrEcoBlu’. The novelty of this engineered machine lies in coupling a biosensor with a microbial fuel cell to transduce a pollution input into an easily measurable electrical output signal. The device consists of two components; the sensor element which is modular, allowing for customisation to detect a range of input signals as required, and the universal reporter element which is responsible for generating an electrical signal as an output. The genetic components produce pyocyanin, a competitive electron mediator for microbial fuel cells, thus enabling the generation of an electrical current in the presence of target chemical pollutants. The pollutants tested in our implementation were toluene and salicylate. ElectrEcoBlu is expected to drive forward the development of a new generation of biosensors. Our approach exploited a range of state-of-the-art modelling techniques in a unified framework of qualitative, stochastic and continuous approaches to support the design and guide the construction of this novel biological machine. This work shows that integrating engineering techniques with scientific methodologies can provide new insights into genetic regulation and can be considered as a reference framework for the development of biochemical systems in synthetic biology.  相似文献   

4.
Despite the amount of resources that have been invested by national and international academic, government, and commercial sectors to develop affinity-based biosensor products, little obvious success has been realized through commercialization of these devices for specific applications (such as the enzyme biosensors for blood glucose analysis). Nevertheless, the fastest growing area in the biosensors research literature continues to involve advances in affinity-based biosensors and biosensor-related methods. Numerous biosensor techniques have been reported that allow researchers to better study the kinetics, structure, and (solid/liquid) interface phenomena associated with protein-ligand binding interactions. In addition, potential application areas for which affinity-based biosensor techniques show promise include clinical/diagnostics, food processing, military/antiterrorism, and environmental monitoring. The design and structural features of these devices—composed of a biological affinity element interfaced to a signal transducer—primarily determine their operational characteristics. This paper although not intended as a comprehensive review, will outline the principles of affinity biosensors with respect to potential application areas.  相似文献   

5.
This review describes recent developments in the field of biosensors and bioelectrochemistry. Nanoparticles have been used to improve sensor performance and to develop biosensors based on new detection principles. Their use has extended into all areas of biosensor and bioelectrochemistry research. Other active areas of biosensor development include DNA sensing, immunosensing, direct electron transfer between an electrode and a redox protein or enzyme, and in vivo sensors.  相似文献   

6.
Nanobiotechnology is defined as an interdisciplinary field of science that studies the application of fine-sized biological objects (of nanoscale, 1–100 nm) to design the devices and systems of the same size that utilize for new purposes the unusual, known, or previously unknown effects. Analysis demonstrates that the final goals, approaches, solution methods, and applications of nanostructures and biological sensors have much in common. This brief review attempts to systematize a number of the available data and pick out an organic connection of the new research direction with the field of biosensor technology, which have reached the level of sustainable development.  相似文献   

7.
Nanobiotechnology is defined as an interdisciplinary field of science that studies the application of fine-sized biological objects (of nanoscale, 1-100 nm) to design the devices and systems of the same size that utilize for new purposes the unusual, known, or previously unknown effects. Analysis demonstrates that the final goals, approaches, solution methods, and applications of nanostructures and biological sensors have much in common. This brief review attempts to systematize a number of the available data and pick out an organic connection of the new research direction with the field of biosensor technology, which have reached the level of sustainable development.  相似文献   

8.
Xue H  Shen Z  Li C 《Biosensors & bioelectronics》2005,20(11):2330-2334
A new type of in situ electropolymerization method was used for electrochemical biosensor design. The biologic film was prepared by in situ electropolymerization of aniline into microporous polyacrylonitrile-coated platinum electrode in the presence of glucose oxidase. The novel glucose biosensor exhibited good selectivity, sensitivity and stability, which showed no apparent loss of activity after 100 consecutive measurements and intermittent usage for 100 days with storage in a phosphate buffer at 4 degrees C. Blood glucose determinations agreed well with standard hospital laboratory analysis. The construction and operational parameters of the biosensor were also optimized.  相似文献   

9.
A novel design of a biochemical oxygen demand (BOD) biosensor has been developed for on-line monitoring of easily biodegradable organic compounds in aqueous samples. The biological recognition element of the sensor could be easily renewed by injecting new bacterial paste without disassembling the sensor system. The sensor measurements were carried out in the initial-rate mode using a flow injection (FI) system, resulting in 60 s for one sample analysis followed by a recovery time less than 10 min. The sensor performance achieved showed a wide detection linearity over the range of 5-700 mg BOD5.l(-1) and a generally good agreement between the BOD values estimated by the biosensor and the conventional 5-day test. Furthermore, the precision test was in the control range (i.e. repeatability < or = /+/-7.5%/, reproducibility < or = /+/-7.3%/). The sensor could be used over 1 week in continuous test, however, the best performance was found within the first 24 h where standard deviation of the sensor response was +/-2.4%. The design of the sensor allows easy and fast renewal of the cells used as sensing elements. Replacement of biological recognition element and calibration of the sensor responses can be performed in a rather simple procedure on a daily regular basis. By using a mixed culture as the bio-receptor, one gets a sensor that reacts to a wide range of substrates. The new sensor construction will thus allow fast and convenient replacement of the bio-receptor and on-line assay of a broad range of substrates. This makes the sensor being an interesting and promising candidate for on-line monitoring of biological treatment process.  相似文献   

10.
Biological molecules such as enzymes and antibodies display a unique capacity to recognize and respond to other molecules in a way which can be exploited in the development of analytical devices. In a biosensor, the biological recognition system creates a physiochemical change proximal to a suitable transducer and thereby converts the concentration of the analyte into a quantifiable electrical signal. The design and construction of these devices requires an imaginative combination of biological, chemical, physical and engineering disciplines. Biosensors will find application in a variety of analytical fields.  相似文献   

11.
Immobilization of enzymes on the transducer surface is a necessary and critical step in the design of biosensors. An overview of the different immobilization techniques reported in the literature is given, dealing with classical adsorption, covalent bonds, entrapment, cross-linking or affinity as well as combination of them and focusing on new original methods as well as the recent introduction of promising nanomaterials such as conducting polymer nanowires, carbon nanotubes or nanoparticles. As indicated in this review, various immobilization methods have been used to develop optical, electrochemical or gravimetric enzymatic biosensors. The choice of the immobilization method is shown to represent an important parameter that affects biosensor performances, mainly in terms of sensitivity, selectivity and stability, by influencing enzyme orientation, loading, mobility, stability, structure and biological activity.  相似文献   

12.
Surface plasmon resonance (SPR)-based biosensing is one of the most advanced label free, real time detection technologies. Numerous research groups with divergent scientific backgrounds have investigated the application of SPR biosensors and studied the fundamental aspects of surface plasmon polaritons that led to new, related instrumentation. As a result, this field continues to be at the forefront of evolving sensing technology. This review emphasizes the new developments in the field of SPR-related instrumentation including optical platforms, chips design, nanoscale approach and new materials. The current tendencies in SPR-based biosensing are identified and the future direction of SPR biosensor technology is broadly discussed.  相似文献   

13.
We here report for the first time the creation of prostate specific antigen (PSA) and Fab anti‐PSA biosensor arrays using UV light‐assisted molecular immobilization (LAMI), aiming at the detection and quantification of PSA, a cancer marker. The technology involves formation of free, reactive thiol groups upon UV excitation of protein aromatic residues located in spatial proximity of disulphide bridges, a conserved structural feature in both PSA and Fab molecules. The created thiol groups bind onto thiol reactive surfaces leading to oriented covalent protein immobilization. Protein activity was confirmed carrying out immunoassays: immobilized PSA was recognized by Fab anti‐PSA in solution and immobilized Fab anti‐PSA cross‐reacted with PSA in solution. LAMI technology proved successful in immobilizing biomedically relevant molecules while preserving their activity, highlighting that insight into how light interacts with biomolecules may lead to new biophotonic technologies. Our work focused on the application of our new engineering principles to the design, analysis, construction, and manipulation of biological systems, and on the discovery and application of new engineering principles inspired by the properties of biological systems.  相似文献   

14.
Insect pathogenic fungi play an important natural role in controlling insect pests. However, few have been successfully commercialized due to low virulence and sensitivity to abiotic stresses that produce inconsistent results in field applications. These limitations are inherent in most naturally occurring biological control agents but development of recombinant DNA techniques has made it possible to significantly improve the insecticidal efficacy of fungi and their tolerance to adverse conditions, including UV. These advances have been achieved by combining new knowledge derived from basic studies of the molecular biology of these pathogens, technical developments that enable very precise regulation of gene expression, and genes encoding insecticidal proteins from other organisms, particularly spiders and scorpions. Recent coverage of genomes is helping determine the identity, origin, and evolution of traits needed for diverse lifestyles and host switching. In future, such knowledge combined with the precision and malleability of molecular techniques will allow design of multiple pathogens with different strategies and host ranges to be used for different ecosystems, and that will avoid the possibility of the host developing resistance. With increasing public concern over the continued use of synthetic chemical insecticides, these new types of biological insecticides offer a range of environmental-friendly options for cost-effective control of insect pests.  相似文献   

15.
Biomolecular-membrane interactions play a critical role in the regulation of many important biological processes such as protein trafficking, cellular signalling and ion channel formation. Peptide/protein–membrane interactions can also destabilise and damage the membrane which can lead to cell death. Characterisation of the molecular details of these binding-mediated membrane destabilisation processes is therefore central to understanding cellular events such as antimicrobial action, membrane-mediated amyloid aggregation, and apoptotic protein induced mitochondrial membrane permeabilisation. Optical biosensors have provided a unique approach to characterising membrane interactions allowing quantitation of binding events and new insight into the kinetic mechanism of these interactions. One of the most commonly used optical biosensor technologies is surface plasmon resonance (SPR) and there have been an increasing number of studies reporting the use of this technique for investigating biophysical analysis of membrane-mediated events. More recently, a number of new optical biosensors based on waveguide techniques have been developed, allowing membrane structure changes to be measured simultaneously with mass binding measurements. These techniques include dual polarisation interferometry (DPI), plasmon waveguide resonance spectroscopy (PWR) and optical waveguide light mode spectroscopy (OWLS). These techniques have expanded the application of optical biosensors to allow the analysis of membrane structure changes during peptide and protein binding. This review provides a theoretical and practical overview of the application of biosensor technology with a specific focus on DPI, PWR and OWLS to study biomembrane-mediated events and the mechanism of biomembrane disruption. This article is part of a Special Issue entitled: Lipid–protein interactions.  相似文献   

16.
Bob Challen  Rainer Cramer 《Proteomics》2022,22(15-16):2100394
Omics analysis by mass spectrometry (MS) is a vast field, with proteomics, metabolomics and lipidomics dominating recent research by exploiting biological MS ionisation techniques. Traditional MS ionisation techniques such as electrospray ionisation have limitations in analyte-specific sensitivity, modes of sampling and throughput, leading to many researchers investigating new ionisation methods for omics research. In this review, we examine the current landscape of these new ionisation techniques, divided into the three groups of (electro)spray-based, laser-based and other miscellaneous ionisation techniques. Due to the wide range of new developments, this review can only provide a starting point for further reading on each ionisation technique, as each have unique benefits, often for specialised applications, which promise beneficial results for different areas in the omics world.  相似文献   

17.
This paper reports experimental developments in the construction and operation of a single-mode fibre-optic evanescent wave biosensor using an exposed core silica single-mode fibre embedded in a silica block. The device was able to monitor the concentration of a blue dye, Procion Blue MX-G, in overlayers of various refractive indices. The practicality of such a biosensor has been demonstrated with a colorimetric enzyme assay system. Penicillin G in the 0-0.4 mM concentration range was monitored at 633 nm by the decoloration of the starch-iodine reagent when Bacillus cereus penicillinase was immobilized over the exposed core of the monomode fibre.  相似文献   

18.
极具有应用前景的生物学检测技术-生物传感器   总被引:3,自引:0,他引:3  
生物传感器是近年逐渐发展起来的一种高新生物学分析检测技术,它将生物学或仿生学信号感应部件紧密连接或整合到传感系统内,具有特异、敏感、快速、便携以及操作简便等优点,发展非常迅速,并且被应用到医疗保健、食品工业、畜牧兽医等多个领域,已成为人们研究的热点之一。本文概述了生物传感器的概念与工作原理、分类、与主要领域的研究应用,分析了生物传感器的产业现状,优点与现存问题,并对其应用发展前景进行了展望。  相似文献   

19.
R S Phadke 《Bio Systems》1992,27(4):203-206
A biosensor is a device which consists of a biological sensing element connected to a transducer. The transducer can be electronic, optical, electrical, etc. This emerging technology offers us a powerful tool which is radically altering our approach to analytical methods. It was realised that enzymes are natural sensors on account of their highly selective nature. Much of the impetus to the work has come from medical requirements. Instant analysis of clinical samples has an obvious appeal to physicians and patients alike. Of particular interest is the possibility of continuous 'in-vivo' monitoring of metabolites, drugs and proteins using miniature, portable systems. In recent years, there has been a growing demand for biosensors in the fields of veterinary science, animal husbandry, the food industry and environmental monitoring. However, the possibility of successful application rests upon future developments. Increasing attention will have to be paid to the engineering of both the basic components and the device on the whole. New biochemical reactions will either have to be discovered or engineered through genetic manipulation or chemical techniques. Optimization of response time, selectivity, stability and low costs should receive priority considerations.  相似文献   

20.
A novel capacitance biosensor based on synthetic phytochelatins for sensitive detection of heavy metals is described. Synthetic phytochelatin (Glu-Cys)(20)Gly (EC20) fused to the maltose binding domain protein was expressed in Escherichia coli and purified for construction of the biosensor. The new biosensor was able to detect Hg(2+), Cd(2+), Pb(2+), Cu(2+) and Zn(2+) ions in concentration range of 100 fM-10 mM, and the order of sensitivity was S(Zn)>S(Cu)>S(Hg)>S(Cd) congruent with S(Pb). The biological sensing element of the sensor could be regenerated using EDTA and the storage stability of the biosensor was 15 days.  相似文献   