首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Acetaminophen and several of its metabolites are separated isocratically on a reversed-phase (C1) column using a mobile phase of 7% methanol and 0.75% glacial acetic acid in 0.1 M KH2PO4. Metabolites that can be separated include the sulfate, glucuronide, cysteine, and mercapturic acid conjugates of acetaminophen, as well as 3-hydroxyacetaminophen, 3-methoxyacetaminophen, and 3-methylthioacetaminophen. Although all of the metabolites can be detected by UV spectrophotometry, the sensitivity limits of detection are improved significantly for acetaminophen and all of the metabolites except the sulfate and glucuronide, by amperometric detection (electrochemical) of the same sample as it elutes from the UV detector. Minimal detectable limits (signal-to-noise ratio 2) for acetaminophen and its metabolites, other than the glucuronide and sulfate conjugates, were in the order of 1–2 ng injected on column using UV detection at 248 nm, and 0.1–0.5 ng using electrochemical detection at + 0.60 V with reference to an Ag/AgCl standard electrode.  相似文献   

2.
A sensitive, specific and precise HPLC–UV assay was developed to quantitate cocaine (COC) and its metabolites benzoylecgonine (BE), norcocaine (NC) and cocaethylene (CE) in rat plasma. After adding 50 μl of the internal standard solution (bupivacaine, 8 μg/ml) and 500 μl of Sørensen's buffer (pH 6) to 100 μl of rat plasma sample, the mixture was extracted with 10 ml of chloroform. The organic layer was transferred to a clean test tube and was evaporated under nitrogen. The residue was reconstituted in 100 μl of mobile phase and 35 μl was injected onto the HPLC column. The mobile phase consisted of methanol–acetonitrile–50 mM monobasic ammonium phosphate (5:7:63, v/v/v) and was maintained at a flow-rate of 0.4 ml/min. Separation of COC and its metabolites was achieved using a Supelcosil ABZ+plus deactivated reversed-phase column (250×2.1 mm I.D., 5 μm). Calibration curves were linear over the range of 25–5000 ng/ml for COC and its three metabolites. The absolute extraction efficiencies for BE, COC, NC, CE and bupivacaine were 56.6%, 78.6%, 61.1%, 76.4% and 67.0%, respectively. COC and its metabolites were stable in mobile phase for 24 h at room temperature and in rat plasma for 2 weeks at −20°C. The limits of detection for BE, COC, NC and CE were 20, 24, 15 and 12.9 ng/ml, respectively. These values correspond to 0.70, 0.84, 0.525 and 0.452 ng of the according compound being injected on column. The within-day coefficient of variation for the four compounds ranged from 3.0% to 9.9% while the between-day precision varied from 3.6% to 14%. This method was used to analyze rat plasma samples after administration of COC alone and in combination with alcohol. The pharmacokinetic profiles of COC and its metabolites in these rats are also described.  相似文献   

3.
In order to determine epirubicin and its metabolites at low concentrations (<38 ng/ml) in small plasma samples, a fast reliable method based on a precipitation pre-treatment and sensitive reversed-phase isocratic HPLC has been developed and validated for epirubicin in the range 5–100 ng/ml. The R.S.D. was 5–9% over this concentration range. For human serum containing 25 ng/ml of epirubicin, the inter- and intra-day variation was <10%. Recoveries of the metabolites epirubicinol, 7-deoxydoxorubicinone and 7-deoxydoxorubicinolone at 20 ng/ml ranged from 94–104%. The assay has been used to study human plasma samples taken during a 96-h infusion of epirubicin in a patient with multiple myeloma. The combined levels of the unseparated metabolites, epirubicin glucuronide and epirubicinol glucuronide, were semiquantitatively determined after treatment with β-glucuronidase. The metabolites epirubicinol and 7-deoxydoxorubicinolone, but not 7-deoxydoxorubicinone, were also detected and measured.  相似文献   

4.
Propofol (P) is metabolized in humans by oxidation to 1,4-di-isopropylquinol (Q). P and Q are in turn conjugated with glucuronic acid to the respective glucuronides, propofol glucuronide (Pgluc), quinol-1-glucuronide (Q1G) and quinol-4-glucuronide (Q4G). Propofol and quinol with their glucuronide conjugates can be measured directly by gradient high-performance liquid chromatographic analysis without enzymic hydrolysis. The glucuronide conjugates were isolated by preparative HPLC from human urine samples. The glucuronides of P and Q were present in plasma and urine, P and Q were present in plasma, but not in urine. Quinol in plasma was present in the oxidised form, the quinone. Calibration curves of the respective glucuronides were constructed by enzymic deconjugation of isolated samples containing different concentrations of the glucuronides. The limit of quantitation of P and quinone in plasma are respectively 0.119 and 0.138 μg/ml. The limit of quantitation of the glucuronides in plasma are respectively: Pgluc 0.370 μg/ml, Q1G 1.02 μg/ml and Q4G 0.278 μg/ml. The corresponding values in urine are: Pgluc 0.264 μg/ml, Q1G 0.731 μg/ml and Q4G 0.199 μg/ml. A pharmacokinetic profile of P with its metabolites is shown, and some preliminary pharmacokinetic parameters of P and Q glucuronides are given.  相似文献   

5.
A sensitive and specific method for the analysis of anisodamine and its metabolites in rat urine by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-MS/MS) was developed. Various extraction techniques (free fraction, acid hydrolyses and enzyme hydrolyses) and their comparison were carried out for investigation of the metabolism of anisodamine. After extraction procedure the pretreated samples were injected on a reversed-phase C18 column with mobile phase (0.2 ml/min) of methanol/0.01% triethylamine solution (adjusted to pH 3.5 with formic acid) (60:40, v/v) and detected by MS/MS. Identification and structural elucidation of the metabolites were performed by comparing their changes in molecular masses (DeltaM), retention-times and full scan MS(n) spectra with those of the parent drug. At least 11 metabolites (N-demethyl-6beta-hydroxytropine, 6beta-hydroxytropine, tropic acid, N-demethylanisodamine, hydroxyanisodamine, anisodamine N-oxide, hydroxyanisodamine N-oxide, glucuronide conjugated N-demethylanisodamine, sulfate conjugated and glucuronide conjugated anisodamine, sulfate conjugated hydroxyanisodamine) and the parent drug were found in rat urine after the administration of a single oral dose 25mg/kg of anisodamine. Hydroxyanisodamine, anisodamine N-oxide and the parent drug were detected in rat urine for up 95 h after ingestion of anisodamine.  相似文献   

6.
Tamoxifen (TAM) is a triphenylethylene anti-oestrogen, commonly used in the treatment of breast cancer. Patients receiving tamoxifen therapy may experience both de novo and acquired resistance. As one of the mechanisms for this may be extensive peripheral bio-transformation of tamoxifen, there has been considerable interest in the pharmacokinetics and metabolism of tamoxifen. A reversed-phase high-performance liquid chromatography separation has been developed to determine the levels of tamoxifen and its major metabolites in human plasma. The method is highly sensitive (2 ng/ml) and selective for tamoxifen, cis-tamoxifen (CIS), 4-hydroxytamoxifen (4-OH) and desmethyltamoxifen (DMT). A μBondapak C18 10 μm column (30 cm × 3.9 mm I.D.) was used, with a mobile phase of methanol-1% triethylamine at pH 8 (89:11, v/v). Sample preparation was carried out using a C2 (500 mg sorbent, 3 ml reservoirs) solid phase extraction method, and extraction efficiencies were approximately 60% for TAM and its metabolites. Accuracy and precision, as determined by spiking plasma samples with a mixture of tamoxifen and its metabolites, ranged from 85–110% (± 5–10%) at 1 μg/ml, 101–118% (± 8–20%) at 0.1 μg/ml and 111–168% (± 43–63%) at 0.01 μg/ml. Results from 59 patients show mean values of 54 ng/ml for 4-OH; 190 ng/ml for DMT; 93 ng/ml for TAM and 30 ng/ml for CIS (detected in three patients only). This methodology can be applied routinely to the determination of TAM and its metabolites in plasma from patients undergoing therapy.  相似文献   

7.
An isocratic high-performance liquid chromatographic (HPLC) method with ultraviolet detection is described for the quantification of the atypical neuroleptic clozapine and its major metabolites, N-desmethylclozapine and clozapine N-oxide, in human serum or plasma. The method included automated solid-phase extraction on C18 reversed-phase material. Clozapine and its metabolites were separated by HPLC on a C18 ODS Hypersil analytical column (5 μm particle size; 250 mm × 4.6 mm I.D.) using an acetonitrile—water (40:60, v/v) eluent buffered with 0.4% (v/v) N,N,N′,N′-tetramethylethylenediamine and acetic acid to pH 6.5. Imipramine served as internal standard. After extraction of 1 ml of serum or plasma, as little as 5 ng/ml of clozapine and 10 or 20 ng/ml of the metabolites were detectable. Linearity was found for drug concentrations between 5 and 2000 ng/ml as indicated by correlation coefficients of 0.998 to 0.985. The intra- and inter-assay coefficients of variation ranged between 1 and 20%. Interferences with other psychotropic drugs such as benzodiazepines, antidepressants or neuroleptics were negligible. In all samples, collected from schizophrenic patients who had been treated with daily oral doses of 75–400 mg of clozapine, the drug and its major metabolite, N-desmethylclozapine, could be detected, while the concentrations of clozapine N-oxide were below 20 ng/ml in three of sixteen patients. Using the method described here, data regarding relations between therapeutic or toxic effects and drug blood levels or metabolism may be collected in clinical practice to improve the therapeutic efficacy of clozapine drug treatment.  相似文献   

8.
A reversed-phase high-performance liquid chromatographic assay was developed to simultaneously quantitate nefiracetam (NEF), a novel nootropic agent, and its three known oxidized metabolites (N-[(2,6-dimethylphenylcarbamoyl)methyl]succinamic acid (5-COOH-NEF), 4-hydroxy-NEF and 5-hydroxy-NEF) in human serum and urine. The quantitative procedure was based on solid-phase extraction with Sep-Pak C18 and ultraviolet detection at 210 nm. The calibration curves of NEF and the metabolites were linear over a wide range of concentrations (0.5–21.5 nmol/ml for NEF and 0.4–9.5 nmol/ml for metabolites in serum and 4–86 nmol/ml for NEF and 8–190 nmol/ml for metabolites in urine). Intra- and inter-day assay coefficients of variation for the compounds were less than 10%. The limit of detection was 0.1 nmol/ml for NEF, 5-COOH-NEF and 4-hydroxy-NEF, and 0.2 nmol/ml for 5-hydroxy-NEF in both serum and urine. This method is applicable for the determination of NEF and its metabolites in human serum and urine with satisfactory accuracy and precision.  相似文献   

9.
An isocratic high-performance liquid chromatographic method with ultraviolet detection was utilized for the investigation of the pharmacokinetics of naringenin and its glucuronide conjugate in rat plasma and brain tissue. Plasma and brain tissue were deproteinized by acetonitrile, then centrifuged for sample clean-up. The drugs were separated by a reversed-phase C18 column with a mobile phase consisting of acetonitrile–orthophosphoric acid solution (pH 2.5–2.8) (36:64, v/v). The detection limits of naringenin in rat plasma and brain tissue were 50 ng/ml and 0.4 μg/g, respectively. The glucuronide conjugate of naringenin was evaluated by the deconjugated enzyme β-glucuronidase. The naringenin conjugation ratios in rat plasma and brain tissue were 0.86 and 0.22, respectively, 10 min after naringenin (20 mg/kg, i.v.) administration. The mean naringenin conjugation ratio in plasma was approximately four fold that in brain tissue.  相似文献   

10.
A method for simultaneous determination of 5-hydroxy-N-methylpyrrolidone and 2-hydroxy-N-methylsuccinimide in urine is described. These compounds are metabolites of N-methyl-2-pyrrolidone, a powerful and widely used organic solvent. 5-Hydroxy-N-methylpyrrolidone and 2-hydroxy-N-methylsuccinimide were purified from urine by adsorption to a C8 solid-phase extraction column and then elution by ethyl acetate–methanol (80:20). After evaporation, the samples were derivatised at 100°C for 1 h by bis(trimethylsilyl)trifluoroacetamide. Ethyl acetate was then added and the samples were analysed by gas chromatography–mass spectrometry in the electron impact mode. The extraction recovery for 5-hydroxy-N-methylpyrrolidone was about 80% while that for 2-hydroxy-N-methylsuccinimide was about 30%. The intra-day precision for 5-hydroxy-N-methylpyrrolidone was 2–4% and the between-day precision 4–21% (4 and 60 μg/ml). The intra-day precision for 2-hydroxy-N-methylsuccinimide was 4–8% and the between-day precision 6–7% (2 and 20 μg/ml). The detection limit was 0.2 μg/ml urine for both compounds. The method is applicable for analysis of urine samples from workers exposed to N-methyl-2-pyrrolidone.  相似文献   

11.
The use of the system, automated sequential trace enrichment of dialysates (ASTED), to prepare plasma samples for the estimation of lamotrigine, its glucuronide and methylated metabolites in plasma prior to gradient high-performance liquid chromatography (HPLC) is described. Using this technique the procedure was observed to be specific for all three compounds and linear over the range 0.04 to 10 μg/ml for lamotrigine and the glucuronide metabolite and 2 to 500 ng/ml for the methylated metabolite. The within-run precision (C.V.) at four different supplemented plasma lamotrigine concentrations of 0.04, 0.10, 2.5 and 10.0 μg/ml was 6.21, 5.17, 1.29 and 0.73%, respectively, and the between-run precision (C.V.) estimated to be 13.49, 6.08, 1.95 and 1.78%, respectively. The overall accuracy (% bias) of the procedure was estimated to be 12.50, 0.00, 2.80 and 1.80%, respectively. The glucuronide and methylated metabolites in plasma showed similar assay performance.  相似文献   

12.
A method for the quantification of clindamycin in human serum and in human bone tissue samples applying high-performance liquid chromatography with atmospheric pressure chemical ionization–mass spectrometry (APCI–MS) is presented. Lincomycin is used as the internal standard. Serum samples are prepared only by protein precipitation with acetonitrile. Bone tissue samples have to be crushed and homogenized in extraction buffer prior to analysis. The chromatographic separation is achieved on an RP-18 stationary phase with 0.02% trifluoroacetic acid in water 60%/acetonitrile 40% v/v as mobile phase. The limits of quantification are 0.1 μg/ml for serum samples and 0.1 μg/g for bone tissue samples. The coefficients of variation for the assays are 4.48 and 8.41% at the limit of quantification for serum and bone tissue samples, respectively. Bone tissue samples as small as 50 mg can be used.  相似文献   

13.
A method for the routine clinical examination of serum gliclazide by high-performance liquid chromatography (HPLC) on a column packed with a macroporous anion-exchange resin, Diaion CDR-10, was developed. The elution was performed with acetonitrile—methyl alcohol—1.2 M ammonium perchlorate (4:3:7, v/v/v) at a flow-rate of 0.4 ml/min. The retention time of gliclazide was 15 min. It seems that the retention mechanism of gliclazide under the HPLC conditions described is not only ion-exchange mode but reversed-phase mode between the anion-exchange resin and the mobile phase. The detection limit of gliclazide was 0.2 μg/ml in plasma. The coefficient of variation for the within-day assay was 5.0% (0.2 μg/ml, n=8). The decay curve of serum gliclazide in diabetic patients was determined.  相似文献   

14.
A reversed-phase high-performance liquid chromatographic method for the determination of the enantiomers of atenolol in rat hepatic microsome has been developed. Racemic atenolol was extracted from alkalinized rat hepatic microsome by ethyl acetate. The organic layer was dried with anhydrous sodium sulfate and evaporated using a gentle stream of air. Atenolol racemic compound was derivatized with 2,3,4,6-tetra-O-acetyl-β- -glycopyranosyl isothiocyanate at 35°C for 30 min to form diastereomers. After removal of excess solvent, the diastereomers were dissolved in phosphate buffer (pH 4.6)–acetonitrile (50:30). The diastereomers were separated on a Shimadzu CLC-C18 column (10 μm particle size, 10 cm×0.46 cm I.D.) with a mobile phase of phosphate buffer–methanol–acetonitrile (50:20:30, v/v) at a flow-rate of 0.5 ml/min. A UV–VIS detector was operated at 254 nm. For each enantiomer, the limit of detection was 0.055 μg/ml (signal-to-noise ratio 3) and the limit of quantification (signal-to-noise ratio 10) was 0.145 μg/ml (RSD <10%). In the range 0.145–20 μg/ml, intra-day coefficients of variation were 1.0–7.0% and inter-day coefficients of variation were 0.4–16.5% for each enantiomer. The assay was applied to determine the concentrations of atenolol enantiomers in rat hepatic microsome as a function of time after incubation of racemic atenolol.  相似文献   

15.
A sensitive and very specific method, using liquid chromatography–electrospray mass spectrometry (LC–ES-MS), was developed for the determination of epirubicin, doxorubicin, daunorubicin, idarubicin and the respective active metabolites of the last three, namely doxorubicinol, daunorubicinol and idarubicinol in human serum, using aclarubicin as internal standard. Once thawed, 0.5-ml serum samples underwent an automated solid-phase extraction, using C18 Bond Elut cartridges (Varian) and a Zymark Rapid-Trace robot. After elution of the compounds with chloroform–2-propanol (4:1, v/v) and evaporation, the residue was reconstituted with a mixture of 5 mM ammonium formate buffer (pH 4.5)–acetonitrile (60:40, v/v). The chromatographic separation was performed using a Symmetry C18, 3.5 μm (150×1 mm I.D.) reversed-phase column, and a mixture of 5 mM ammonium formate buffer (pH 3)–acetonitrile (70:30, v/v) as mobile phase, delivered at 50 μl/min. The compounds were detected in the selected ion monitoring mode using, as quantitation ions, m/z 291 for idarubicin and idarubicinol, m/z 321 for daunorubicin and daunorubicinol, m/z 361 for epirubicin and doxorubicin, m/z 363 for doxorubicinol and m/z 812 for aclarubicin (I.S.). Extraction recovery was between 71 and 105% depending on compounds and concentration. The limit of detection was 0.5 ng/ml for daunorubicin and idarubicinol, 1 ng/ml for doxorubicin, epirubicin and idarubicin, 2 ng/ml for daunorubicinol and 2.5 ng/ml for doxorubicinol. The limit of quantitation (LOQ) was 2.5 ng/ml for doxorubicin, epirubicin and daunorubicinol, and 5 ng/ml for daunorubicin, idarubicin, doxorubicinol and idarubicinol. Linearity was verified from these LOQs up to 2000 ng/ml for the parent drugs (r≥0.992) and 200 ng/ml for the active metabolites (r≥0.985). Above LOQ, the within-day and between-day precision relative standard deviation values were all less than 15%. This assay was applied successfully to the analysis of human serum samples collected in patients administered doxorubicin or daunorubicin intravenously. This method is rapid, reliable, allows an easy sample preparation owing to the automated extraction and a high selectivity owing to MS detection.  相似文献   

16.
A high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of aspirin and salicylic acid in transdermal perfusates. The compounds were separated on a C8 Nucleosil column (5 μm, 250×4.6 mm) using a mobile phase containing a mixture of water–acetonitrile–orthophosphoric acid (650:350:2, v/v/v) and a flow-rate of 1 ml/min. The transdermal samples were in phosphate-buffered saline (PBS) and could be injected directly onto the HPLC system. The method was reproducible with inter-day R.S.D. values of no greater than 3.46 and 2.60% for aspirin and salicylic acid, respectively. The method was linear over the concentration range 0.2–5.0 μg/ml and had a limit of detection of 0.05 μg/ml for both compounds. For certain samples, it was necessary to ensure that no transmembrane leakage of the aspirin prodrugs had occurred. In these cases, a gradient was introduced by increasing the acetonitrile content of the mobile phase after the salicylic acid had eluted. The method has been applied to the determination of aspirin and salicylic acid in PBS following in vitro application of the compounds to mouse skin samples.  相似文献   

17.
A procedure is described to simultaneously quantitate phenolphthalein and its glucuronide metabolite from dog serum, urine and bile using high-performance liquid chromatography. The major advantages of this over pre-existing methods include direct analysis of the parent compound and glucuronide metabolite without enzymatic hydrolysis, increased sensitivity and the potential for automation of a large number of samples. Analytes were extracted from serum and urine using a combination of liquid- and solid-phase extraction methodology. Bile samples were analyzed directly after a twenty-fold dilution with mobile phase. The components plus internal standard were separated by reversed-phase high-performance liquid chromatography using step gradient elution and quantitated by the absorbance of ultraviolet light at 230 nm. Limits of detection from 1 ml of serum, 0.1 ml of urine and 0.05 ml of bile were 0.1, 0.5 and 10 μg/ml for phenolphthalein and 0.1, 10 and 50 μg/ml for phenolphthalein glucuronide, respectively.  相似文献   

18.
19.
A rapid and sensitive method was developed for the simultaneous determination of the new doxorubicin glucuronide prodrug HMR 1826, the parent drug doxorubicin and its metabolites in human lung tissue samples. Homogenization of frozen tissue samples with the micro-dismembrator was followed by a silver nitrate precipitation step. By removing the exceeding silver ions with sodium chloride further purification steps could be omitted. Compounds were separated by isocratic high-performance liquid chromatography on a LiChrospher 100 RP18 column and a mobile phase consisting of citric acid buffer–acetonitrile–methanol–tetrahydrofuran within 30 min and quantified with fluorescence detection. The method showed good recoveries for all compounds (86–99%) and a linear calibration range of 20 ng/g–80 μg/g for doxorubicin and 1–600 μg/g for HMR 1826.  相似文献   

20.
A rapid and specific high-performance liquid chromatographic assay was developed for the determination of acetaminophen glucuronide formed by human liver microsomes. In addition, incubation conditions were systematically evaluated. Conditions that yielded the optimal rate of acetaminophen glucuronide formation over various concentrations of acetaminophen (0.15–30 mM) consisted of the following: 0.1 M potassium phosphate buffer, 1 mM magnesium chloride, 30 μg/mg alamethicin, 4 mM uridine 5′-diphosphoglucuronic acid at a pH of 7.1. Alamethicin produced higher and more consistent APAPG formation rates compared to Brij-58. Adding saccharolactone to the incubation medium reduced the velocity of the reaction. Acetaminophen glucuronide, acetaminophen, and the internal standard (paraxanthine), were analyzed on a C18 column with UV detection at 250 nm. The mean correlation coefficient (r2) of the standard curves for acetaminophen glucuronide was >0.99 over the range of 0.1–25 nmol. The intra- and inter-day coefficients of variation were <4%. This method is suitable for in vitro studies using acetaminophen glucuronide formation as an index reaction for UGT activity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号