首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
A gas chromatographic-mass spectrometric method is presented which allows the simultaneous determination of the plasma concentrations of fluvoxamine and of the enantiomers of fluoxetine and norfluoxetine after derivatization with the chiral reagent, (S)-(-)-N-trifluoroacetylprolyl chloride. No interference was observed from endogenous compounds following the extraction of plasma samples from six different human subjects. The standard curves were linear over a working range of 10 to 750 ng/ml for racemic fluoxetine and norfluoxetine and of 50 to 500 ng/ml for fluvoxamine. Recoveries ranged from 50 to 66% for the three compounds. Intra- and inter-day coefficients of variation ranged from 4 to 10% for fluvoxamine and from 4 to 13% for fluoxetine and norfluoxetine. The limits of quantitation of the method were found to be 2 ng/ml for fluvoxamine and 1 ng/ml for the (R)- and (S)-enantiomers of fluoxetine and norfluoxetine, hence allowing its use for single dose pharmacokinetics. Finally, by using a steeper gradient of temperature, much shorter analysis times are obtained if one is interested in the concentrations of fluvoxamine alone.  相似文献   

2.
A gas chromatographic–mass spectrometric method for the simultaneous determination of methionine and total homocysteine in human plasma is described. dl-[2H4]Methionine and dl-[2H8]homocystine were used as internal standards. The method involved reduction of the disulfide bond with dithiothreitol, purification by cation-exchange chromatography using a BondElut SCX cartridge and derivatization with isobutyl chlorocarbonate in water–ethanol–pyridine. Quantitation was performed by selected-ion monitoring of the quasi-molecular ions of N(O,S)-isobutyloxycarbonyl ethyl ester (IBC-OEt) derivatives for methionine and [2H4]methionine, respectively, and the fragment ions ([M+H–COOisoBu–COOEt]+) for IBC-OEt derivatives for homocysteine and [2H4]homocysteine, respectively. The sensitivity, specificity, accuracy and precision of the method were demonstrated to be satisfactory for measuring concentrations of methionine and total homocysteine in human plasma.  相似文献   

3.
A sensitive gas chromatographic assay using mass selective-detection has been developed for the simultaneous quantitation of the enantiomers of (±)-gacyclidine (a non competitive N-methyl-

-aspartate antagonist) in human plasma. Gacyclidine enantiomers and phencyclidine (PCP), the internal standard, were extracted using a single-step liquid–liquid extraction with hexane at pH 8.0. Each enantiomer was separated on a chiral gas chromatography capillary column and specifically detected by mass spectrometry (MS) in selected-ion monitoring (SIM) mode. Gacyclidine enantiomers and PCP were monitored using the fragment ions at m/z 206 and 200, respectively. No interference was observed from endogenous components. The limit of quantitation (LOQ) for each enantiomer of gacyclidine was 300 pg/ml by using plasma samples of 500 μl. The calibration curves were linear (r2=0.998) over a range of 0.3125 to 20 ng/ml. The extraction efficiency was higher than 95% for both enantiomers. Intra- and inter-day bias were less than 10% at every standard curve concentration. Intra-day precision was less than 19% for (−)-gacyclidine and 15% for (+)-gacyclidine. Inter-day precision was below 15% for both enantiomers. The assay was validated for an enantioselective pharmacokinetic study in healthy male volunteers.  相似文献   

4.
In order to study the disposition of dimethylamphetamine (DMAP) and its metabolites, DMAP N-oxide, methamphetamine (MA) and amphetamine (AP), from plasma to hair in rats, a simultaneous determination method for these compounds in biological samples using gas chromatography–mass spectrometry with selected ion monitoring (GC–MS-SIM) was developed. As DMAP N-oxide partially degrades to DMAP and MA during GC–MS analysis, it was necessary to avoid conditions which co-extract the N-oxide in the sample preparation so as to assure no contribution of artifactual products from DMAP N-oxide in the detection of the other compounds. For confirmation of the satisfactory separation of DMAP N-oxide from the others, the internal standards used for quantification were labeled with different numbers of deuterium atoms. Determination of unchanged DMAP was performed without any derivatization, that of DMAP N-oxide was carried out after conversion into trifluoroacetyl-MA by reaction with trifluoroacetic anhydride, and MA and AP were quantified after trifluoroacetyl-derivatization.After intraperitoneal administration of DMAP HCl to pigmented hairy rats (5 mg kg−1 day−1, 10 days, n=3), concentrations of DMAP and its metabolites in urine, plasma and hair were measured by GC–MS-SIM. The area under the concentration versus time curves (AUCs) of DMAP, DMAP N-oxide, MA and AP in the plasma were 397.2±97.5, 279.7±68.3, 18.4±1.2 and 15.9±2.2 μg min ml−1, while their concentrations in the hair newly grown for 4 weeks after administration were 4.82±0.67. 0.45±0.09, 3.25±0.36 and 0.89±0.05 ng mg−1, respectively. This fact suggested that the incorporation tendency of DMAP N-oxide from plasma into hair was distinctly low in comparison with the other compounds.  相似文献   

5.
A rapid and economical method for the determination in meat of androgens, estrogens, progestogens and corticoids, including some precursors and metabolites, has been developed. The extracted steroids are separated in a polar, a neutral, and a phenolic fraction by C8-SPE followed by a liquid–liquid extraction of the phenolates. Each fraction is separately purified by normal-phase SPE. The different steroid fractions can be analysed either together to obtain a comprehensive hormone pattern in one step or separately to enhance detection selectivity and sensitivity. Using a universally applicable silylation of the hydroxyl and keto groups, detection limits of 0.02–0.1 μg/kg are reached by GC–MS (EI) in the selected ion monitoring mode.  相似文献   

6.
Enantioselective multidimensional gas chromatography–mass spectrometry is a valuable tool for the enantioselective analysis of compounds from complex matrices. Samples are separated initially on a precolumn and selected substances then transferred on-line to a main-column coated with suitable chiral stationary phase for enantioselective analysis with subsequent mass selective detection. In this paper the method is used as an adjunct to urinary organic acid analysis to provide information in patients with suspected inborn errors of metabolism. Lactic acid, α-hydroxyisocaproic acid, 3-phenyllactic acid and 3-(4-hydroxyphenyl)-lactic acid are separated in a single run. In addition, the enantioselective analysis of pyroglutamic acid is presented. d-Enantiomers of amino acids and α-hydroxycarboxylic acids derived from amino acids, point to a bacterial origin whereas the l-enantiomer is predominantly of endogenous origin. Therefore the enantiomeric ratio of chiral metabolites is an important parameter for the understanding of metabolic processes.  相似文献   

7.
Quantitative analysis of therapeutic compounds and their metabolites in biological matrix (such as plasma, serum or urine) nowadays requires sensitive and selective methods to allow the determination of concentrations in the ng/ml range. A new on-line LC–MS–MS method using atmospheric pressure chemical ionisation (APCI) as interface for the simultaneous determination of nifedipine (NIF) and its metabolite in human plasma, dehydronifedipine (DNIF) has been developed. The compounds were extracted from plasma using solid-phase extraction (SPE) on disposable extraction cartridges (DECs). The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with phenyl modified silica was first conditioned with methanol and water. The washing step was performed with water. Finally, the analytes were successively eluted with methanol and water. The liquid chromatographic (LC) separation of NIF and DNIF was achieved on a RP-18 stationary phase (4 μm). The mobile phase consisted of methanol–50 mM ammonium acetate solution (50:50, v/v). The LC was then coupled to tandem mass spectrometry with an APCI interface in the positive ion mode.

The method developed was validated. The absolute recoveries evaluated over the whole concentration range were 95±2% and 95±4% for NIF and DNIF, respectively. The method was found to be linear in the 0.5–100 ng/ml concentration range for the two analytes (r2=0.999 for both NIF and DNIF). The mean R.S.D. values for repeatability and intermediate precision were 2.9 and 3.0% for NIF and 2.2–4.7% for the metabolite.The method developed was successfully used to investigate the plasma concentration of NIF and DNIF in the pharmacokinetic studies.  相似文献   


8.
A rapid, selective, sensitive and reproducible liquid chromatographic method with tandem mass spectrometric detection has been developed and validated for the analysis of a new specific bradycardic agent, ivabradine (S 16257) and six potentially active metabolites in human plasma. Isolation of these compounds and of the internal standard was performed by an automated solid-phase extraction system using Oasis cartridges. Separation and detection of ivabradine and its metabolites were achieved using a C18 column and a MS–MS detector with a positive electrospray ionization source. Ivabradine and its metabolites gave a linear response ranging from 0.1 or 0.2 to 20 ng/ml and the limits of quantitation ranged from 0.1 to 0.2 ng/ml using a 0.5 ml plasma sample size. A complete validation demonstrated the method to be accurate, precise and specific for the simultaneous quantification of ivabradine and its metabolites in human plasma. The method was subsequently applied to the quantitative determination of ivabradine and its metabolites in human plasma samples from healthy volunteers participating in a clinical study to provide pharmacokinetic data.  相似文献   

9.
A sensitive enantioselective liquid chromatographic assay with mass spectrometric detection has been developed and validated for the simultaneous determination of plasma concentrations of (R)- and (S)-ketamine, and (R)- and (S)-norketamine. The compounds were extracted from human plasma using solid-phase extraction and then directly injected into the LC-MS system for detection and quantification. Enantioselective separations were achieved on a liquid chromatographic chiral stationary phase based upon immobilized alpha(1)-acid glycoprotein (the Chiral AGP column). The separations were achieved using a mobile phase composed of 2-propanol-ammonium acetate buffer (10 mM, pH 7.6) (6:94, v/v), a flow-rate of 0.5 ml/min and a temperature of 25 degrees C. Under these conditions, the analysis time was 20 min. Detection of the ketamine, norketamine and bromoketamine (internal standard) enantiomers was achieved using selected ion monitoring at m/z 238.1, 224.1 and 284.0, respectively. Extracted calibration curves were linear from 1 to 125 ng/ml per enantiomer for each analyte with correlation coefficients better than 0.9993 and intra- and inter-day RSDs of less than 8.0%. The method was applied to samples from a clinical study of ketamine in pain management.  相似文献   

10.
A gas chromatographic–mass spectrometric method was developed for the simultaneous analysis of 15 low-dosed benzodiazepines, both parent compounds and their corresponding metabolites, in human urine. The target compounds are alprazolam, -hydroxyalprazolam, 4-hydroxyalprazolam, flunitrazepam, 7-aminoflunitrazepam, desmethylflunitrazepam, flurazepam, hydroxyethylflurazepam, nitrogen-desalkylflurazepam, ketazolam, oxazepam, lormetazepam, lorazepam, triazolam and -hydroxytriazolam. Nitrogen-methylclonazepam is used as the internal standard. The urine sample preparation involves enzymatic hydrolysis of the conjugated metabolites with Helix pomatia β-glucuronidase for 1 h at 56°C followed by solid-phase extraction on a phenyl-type column. The extracted benzodiazepines are subsequently analyzed on a polydimethylsiloxane column using on-column injection to enhance sensitivity. The extraction efficiency exceeded 80% for all compounds except for oxazepam, lorazepam and 4-hydroxyalprazolam which had recoveries of about 60%. The LODs ranged from 13 to 30 ng/ml in the scan mode and from 1.0 to 1.7 ng/ml in the selected ion monitoring (SIM) mode. Linear calibration curves were obtained in the concentration ranges from 50 to 1000 ng/ml in the scan mode and from 5 to 100 ng/ml in the SIM mode. The within-day and day-to-day relative standard deviations at three different concentrations never exceeded 15%.  相似文献   

11.
The present study describes the simultaneous determination of seven different kinds of local anesthetics and one metabolite by GC–MS with solid-state extraction: Mepivacaine, propitocaine, lidocaine, procaine (an ester-type local anesthetics), cocaine, tetracaine (an ester-type local anesthetics), dibucaine (Dib) and monoethylglycinexylidide (a metabolite of lidocaine) were clearly separated from each other and simultaneously determined by GC–MS using a DB-1 open tubular column. Their recoveries ranged from 73–95% at the target concentrations of 1.00, 10.0 and 100 μg/ml in plasma, urine and water. Coefficients of variation of the recoveries ranged from 2.3–13.1% at these concentrations. The quantitation limits of the method were approximately 100 ng/ml for monoethylglycinexylidide, propitocaine, procaine, cocaine, tetracaine and dibucaine, and 50 ng/ml for lidocaine and mepivacaine. This method was applied to specimens of patients who had been treated with drip infusion of lidocaine, and revealed that simultaneous determination of lidocaine and monoethylglycinexylidide in the blood and urine was possible.  相似文献   

12.
For the first time, an LC–MS–MS method has been developed for the simultaneous analysis of buprenorphine (BUP), norbuprenorphine (NBUP), and buprenorphine–glucuronide (BUPG) in plasma. Analytes were isolated from plasma by C18 SPE and separated by gradient RP-LC. Electrospray ionization and MS–MS analyses were carried out using a PE-Sciex API-3000 tandem mass spectrometer. The m/z 644→m/z 468 transition was monitored for BUPG, whereas for BUP, BUP-d4, NBUP, and NBUP-d3 it was necessary to monitor the surviving parent ions in order to achieve the required sensitivity. The method exhibited good linearity from 0.1 to 50 ng/ml (r2≥0.998). Extraction recovery was higher than 77% for BUPG and higher than 88% for both BUP and NBUP. The LOQ was established at 0.1 ng/ml for the three analytes. The method was validated on plasma samples collected in a controlled intravenous and sublingual buprenorphine administration study. Norbuprenorphine–glucuronide was also tentatively detected in plasma by monitoring the m/z 590→m/z 414 transition.  相似文献   

13.
A gas chromatography–electron capture mass spectrometry assay has been developed for the histamine H3 receptor agonist, Nα-methylhistamine (Nα-MH). The assay is linear from 50 pg–10 ng, with a limit of detection of 50 pg/ml for gastric juice and plasma, and 50 pg/sample for bacteria (107–108 CFU) and gastric tissue (5–10 mg wet weight). The limits of quantification are 100 pg/ml for gastric juice (%RSD=1.4) and plasma (%RSD=9.4), and 100 pg/sample for bacteria (%RSD=3.9) and tissue (%RSD=5.8). Nα-MH was not present in human plasma, but low levels (1.4 ng/ml and 0.4 ng/ml) were detected in two samples of human gastric juice obtained from patients infected with Helicobacter pylori.  相似文献   

14.
A highly specific method for the determination of the plasma level of the potent vasodilator 2-(N-benzyl-N-methylamino)ethyl methyl 2,6-dimethyl-4-(m-nitrophenyl)-1,4-dihydropyridine carboxylate hydrochloride (nicardipine hydrochloride) in rats, dogs and humans is described. N-d3-Methyl derivative was added as an internal standard, then the plasma was extracted with diethyl ether and subjected to thin-layer chromatography (TLC) to remove the pyridine analogue, one of the drug's metabolites. The area corresponding to the unchanged drug was identified with simultaneously run N-d7-benzyl derivative under UV light. The unchanged drug with a 1,4-dihydropyridine structure was oxidized with nitrous acid to its pyridine analogue, which was stable for gas chromatography, and subjected to mass spectrometry at m/e 134 (nicardipine) and m/e 137 (N-d3-methyl derivative). The sensitivity limit was 5 ng ml−1. The ratio of the unchanged drug to the value obtained by the method without TLC separation was 100% for rats and 80% for dogs and humans at almost all times investigated after dosing. These results demonstrate that in these species, the amount of pyridine analogue in plasma was very small compared with that of the parent drug.  相似文献   

15.
A simple method for the measurement of pindolol enantiomers by HPLC is presented. Alkalinized serum or urine is extracted with ethyl acetate and the residue remaining after evaporation of the organic layer is then derivatised with (S)-(−)-α-methylbenzyl isocyanate. The diastereoisomers of derivatised pindolol and metoprolol (internal standard) are separated by high-performance liquid chromatography (HPLC) using a C18 silica column and detected using fluorescence (excitation λ: 215 nm, emission λ: 320 nm). The assay displays reproducible linearity for pindolol enantiomers with a correlation coefficient of r2≥0.998 over the concentration range 8–100 ng ml−1 for plasma and 0.1–2.5 μg ml−1 for urine. The coefficient of variation for accuracy and precision of the quality control samples for both plasma and urine are consistently <10%. Assay parameters are similar to those of previously published assays for pindolol enantiomers, however this assay is significantly easier and cheaper to run. Clinically relevant concentrations of each pindolol enantiomer can readily be measured.  相似文献   

16.
A rapid, selective and sensitive HPLC–tandem mass spectrometry method was developed and validated for simultaneous determination of flupirtine and its active metabolite D-13223 in human plasma. The analytes and internal standard diphenhydramine were extracted from plasma samples by liquid–liquid extraction, and chromatographed on a C18 column. The mobile phase consisted of acetonitrile–water–formic acid (60:40:1, v/v/v), at a flow rate of 0.5 ml/min. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method has a limit of quantitation of 10 ng/ml for flupirtine and 2 ng/ml for D-13223, using 0.5-ml plasma sample. The linear calibration curves were obtained in the concentration range of 10.0–1500.0 ng/ml for flupirtine and 2.0–300.0 ng/ml for D-13223. The intra- and inter-run precision (RSD), calculated from quality control (QC) samples was less than 7.2% for flupirtine and D-13223. The accuracy as determined from QC samples was less than 5% for the analytes. The overall extraction recoveries of flupirtine and D-13223 were determined to be about 66% and 78% on average, respectively. The method was applied for the evaluation of the pharmacokinetics of flupirtine and active metabolite D-13223 in volunteers following peroral administration.  相似文献   

17.
Two methods were developed for the determination of mexiletine enantiomers in plasma samples suitable for studies on the stereoselective disposition of this drug. Both methods used fluorescence detection to improve sensitivity and selectivity. The direct enantioselective separation was based on the chiral resolution of mexiletine-2-naphthamide derivatives on a Chiralcel OJ column. The calibration curves were linear over the concentration range 50–500 ng/ml for each enantiomer; therefore the method can be used only for therapeutic monitoring, drug interaction and multiple dose pharmacokinetic studies. The indirect method was based on the formation of diastereomers using o-phthaldialdehyde and N-acetyl-l-cysteine reagents. The diastereomers were resolved on a reversed-phase RP-18 column. The method proved to be suitable for single or multiple dose pharmakokinetic studies based on the loq quantification limit ng/ml) and the broader linear range (1–1000 ng/ml) obtained.  相似文献   

18.
A sensitive, selective, and reproducible GC–MS–SIM method was developed for determination of artemether (ARM) and dihydroartemisinin (DHA) in plasma using artemisinin (ART) as internal standard. Solid phase extraction was performed using C18 Bond Elut cartridges. The analysis was carried out using a HP-5MS 5% phenylmethylsiloxane capillary column. The recoveries of ARM, DHA and ART were 94.9±1.6%, 92.2±4.1% and 81.3±1.2%, respectively. The limit of quantification in plasma was 5 ng/ml (C.V.≤17.4% for ARM and 15.2% for DHA). Calibration curves were linear with R2≥0.988. Within day coefficients of variation were 3–10.4% for ARM and 7.7–14.5% for DHA. Between day coefficients of variations were 6.5–15.4% and 7.6–14.1% for ARM and DHA. The method is currently being used for pharmacokinetic studies. Preliminary data on pharmacokinetics showed Cmax of 245.2 and 35.6 ng/ml reached at 2 and 3 h and AUC0–8h of 2463.6 and 111.8 ngh/ml for ARM and DHA, respectively.  相似文献   

19.
Although the fluorinated inhalation anesthetics, including desflurane, sevoflurane, isoflurane, enflurane, and halothane are commonly used, fatal cases resulting from their abuse or misuse have been reported. To date, gas chromatography (GC) equipped with different kinds of detectors has been utilized to analyze inhalation anesthetics. However, none of them can detect desflurane reliably or analyze all five common anesthetics simultaneously. The purpose of the present work is to further modify the previously developed headspace (HS) GC–MS method for blood isoflurane determination to analyze and distinguish five common clinical inhalation anesthetics, simultaneously. The modified HS-GC–MS method adopts a 60 m×0.25 mm I.D., 0.25 μm film thickness DB-5 capillary column along with an adequate GC temperature program, which gives the five inhalation anesthetics, including isoflurane and its isomer, enflurane, a high resolution. The method also takes both the volatility and the influence of the top space on the obtained concentration into consideration and therefore keeps the sample loss acceptable even for analyzing the highly volatile desflurane. Within a certain concentration range of the calibration standard (about 20–300 μg/ml), this method shows a good linearity with correlation coefficients greater than 0.999. In addition, both within- and between-run precision and accuracy results meet the validation requirements as well as the tested results of practical blood samples of desflurane. In summary, this is a reliable analytical method to simultaneously determine the concentration of five common inhalation anesthetics in blood. Such a method is very practical for both clinical and occupational monitoring, as well as for analytical toxicology.  相似文献   

20.
The purpose of this study was to develop a simple and accurate analytical method to determine amino acids in urine samples. The developed method involves the employment of an extract derivatization technique together with gas chromatography-mass spectrometry (GC-MS). Urine samples (300 microl) and an internal standard (10 microl) were placed in a screw tube. Ethylchloroformate (50 microl), methanol-pyridine (500 microl, 4:1, v/v) and chloroform (1 ml) were added to the tube. The organic layer (1 microl) was injected to a GC-MS system. In this proposed method, the amino acids in urine were derivatized during an extraction, and the analytes were then injected to GC-MS without an evaporation of the organic solvent extracted. Sample preparation was only required for ca. 5 min. The 15 amino acids (alanine, aspartic acid, cysteine, glutamic acid, glycine, histidine, isoleucine, leucine, lysine, methionine, phenylalanine, proline, tyrosine, tryptophan, valine) quantitatively determined in this proposed method. However, threonine, serine, asparagine, glutamine, arginine were not derivatized using any tested derivatizing reagent. The calibration curves showed linearity in the range of 1.0-300 microg/ml for each amino acid in urine. The correlation coefficients of the calibration curves of the tested amino acids were from 0.966 to 0.998. The limit of detection in urine was 0.5 microg/ml except for aspartic acid. This proposed method demonstrated substantial accuracy for detection of normal levels. This proposed method was limited for the determination of 15 amino acids in urine. However, the sample preparation was simple and rapid, and this method is suitable for a routine analysis of amino acids in urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏