首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An immunochromatographic-based assay (Quixtrade mark E. coli O157 Sprout Assay) and a polymerase chain reaction (PCR)-based assay (TaqMan E. coli O157:H7 Kit) were used to detect Escherichia coli O157:H7 strain 380-94 in spent irrigation water from alfalfa sprouts grown from artificially contaminated seeds. Ten, 25, 60, or 100 seeds contaminated by immersion for 15 min in a suspension of E. coli O157:H7 at concentrations of 10(6) or 10(8) cfu/ml were mixed with 20 g of non-inoculated seeds in plastic trays for sprouting. The seeds were sprayed with tap water for 15 s every hour and spent irrigation water was collected at intervals and tested. E. coli O157:H7 was detected in non-enriched water by both the TaqMan PCR (30 of 30 samples) and the immunoassay (9 of 24 samples) in water collected 30 h from the start of the sprouting process. However, enrichment of the spent irrigation water in brain heart infusion (BHI) broth at 37 degrees C for 20 h permitted detection of E. coli O157:H7 in water collected 8 h from the start of sprouting using both methods, even in trays containing as few as 10 inoculated seeds. The TaqMan PCR assay was more sensitive (more positive samples were observed earlier in the sprouting process) than the immunoassay; however, the immunoassay was easier to perform and was more rapid. At 72 h after the start of the sprouting process, the sprouts were heated at 100 degrees C for 30 s to determine the effectiveness of blanching for inactivation of E. coli O157:H7. All of the 32 samples tested with the TaqMan assay and 16 of 32 samples tested with the Quixtrade mark assay gave positive results for E. coli O157:H7 after enrichment of the blanched sprouts at 37 degrees C for 24 h. In addition, the organism was detected on Rainbow Agar O157 in 9 of 32 samples after 24 h of enrichment of the blanched sprouts. In conclusion, E. coli O157:H7 was detected in spent irrigation water collected from sprouts grown from artificially contaminated seeds by both the TaqMan and Quixtrade mark assays. The data also revealed that blanching may not be effective to completely inactivate all the E. coli O157:H7 that may be present in sprouts.  相似文献   

2.
AIMS: To apply the real-time Polymerase chain reaction (PCR) method to detect and quantify Escherichia coli O157:H7 in soil, manure, faeces and dairy waste washwater. METHODS AND RESULTS: Soil samples were spiked with E. coli O157:H7 and subjected to a single enrichment step prior to multiplex PCR. Other environmental samples suspected of harbouring E.coli O157:H7 were also analysed. The sensitivity of the primers was confirmed with DNA from E.coli O157:H7 strain 3081 spiked into soil by multiplex PCR assay. A linear relationship was measured between the fluorescence threshold cycle (C T ) value and colony counts (CFU ml(-1)) in spiked soil and other environmental samples. The detection limit for E.coli O157:H7 in the real-time PCR assay was 3.5 x 10(3) CFU ml(-1) in pure culture and 2.6 x 10(4) CFU g(-1) in the environmental samples. Use of a 16-h enrichment step for spiked samples enabled detection of <10 CFU g(-1) soil. E. coli colony counts as determined by the real-time PCR assay, were in the range of 2.0 x 10(2) to 6.0 x 10(5) CFU PCR (-1) in manure, faeces and waste washwater. CONCLUSIONS: The real-time PCR-based assay enabled sensitive and rapid quantification of E. coli O157:H7 in soil and other environmental samples. SIGNIFICANCE AND IMPACT OF THE STUDY: The ability to quantitatively determine cell counts of E.coli O157:H7 in large numbers of environmental samples, represents considerable advancement in the area of pathogen quantification for risk assessment and transport studies.  相似文献   

3.
A new rapid test platform for the direct detection of E. coli O157:H7 in stool samples of infected patients was compared with the current standard methods. The new test, DIAPRO FAST-Q®, used biochip ICEflo ®technology that provided results within 20 min. Twenty-one stool samples from patients infected with E. coli O157:H7 or of unknown status were studied. Using the DIAPRO FAST-Q® method, within 20 min, we confirmed positive results for the seven known E. coli O157:H7 samples. While the standard culture method gave rise to only four positives in the remaining 14 unknown samples, the DIAPRO FAST-Q® detected E. coli O157:H7 in eight of these samples, which was confirmed subsequently by broth enrichment culture method.  相似文献   

4.
Molecular beacons (MBs) are oligonucleotide probes that fluoresce upon hybridization. In this paper, we described the development of a real-time PCR assay to detect the presence of Escherichia coli O157:H7 using these fluorogenic reporter molecules. MBs were designed to recognize a 26-bp region of the rfbE gene, coding for an enzyme necessary for O-antigen biosynthesis. The specificity of the MB-based PCR assay was evaluated using various enterohemorrhagic (EHEC) and Shiga-like toxin-producing (STEC) E. coli strains as well as bacteria species that cross-react with the O157 antisera. All E. coli serotype O157 tested was positively identified while all other species, including the closely related O55 were not detected by the assay. Positive detection of E. coli O157:H7 was demonstrated when >10(2) CFU/ml was present in the samples. The capability of the assay to detect E. coli O157:H7 in raw milk and apple juice was demonstrated. As few as 1 CFU/ml was detected after 6 h of enrichment. These assays could be carried out entirely in sealed PCR tubes, enabling rapid and semiautomated detection of E. coli O157:H7 in food and environmental samples.  相似文献   

5.
AIMS: Combinations of PCR primer sets were evaluated to establish a multiplex PCR method to specifically detect Escherichia coli O157:H7 genes in bovine faecal samples. METHODS AND RESULTS: A multiplex PCR method combining three primer sets for the E. coli O157:H7 genes rfbE, uidA and E. coli H7 fliC was developed and tested for sensitivity and specificity with pure cultures of 27 E. coli serotype O157 strains, 88 non-O157 E. coli strains, predominantly bovine in origin and five bacterial strains other than E. coli. The PCR method was very specific in the detection of E. coli O157:H7 and O157:H- strains, and the detection limit in seeded bovine faecal samples was <10 CFU g(-1) faeces, following an 18-h enrichment at 37 degrees C, and could be performed using crude DNA extracts as template. CONCLUSIONS: A new multiplex PCR method was developed to detect E. coli O157:H7 and O157:H-, and was shown to be highly specific and sensitive for these strains both in pure culture and in crude DNA extracts prepared from inoculated bovine faecal samples. SIGNIFICANCE AND IMPACT OF THE STUDY: This new multiplex PCR method is suitable for the rapid detection of E. coli O157:H7 and O157:H- genes in ruminant faecal samples.  相似文献   

6.
The detection sensitivity and potential interference factors of a commonly used assay based on real-time polymerase chain reaction (PCR) for Escherichia coli O157:H7 using eae gene-specific primers were assessed. Animal wastes and soil samples were spiked with known replicate quantities of a nontoxigenic strain of E. coli O157:H7 in a viable or dead state and as unprotected DNA. The detection sensitivity and accuracy of real-time PCR for E. coli O157:H7 in animal wastes and soil is low compared to enrichment culturing. Nonviable cells and unprotected DNA were shown to produce positive results in several of the environmental samples tested, leading to potential overestimates of cell numbers due to prolonged detection of nonviable cells. This demonstrates the necessity for the specific calibration of real-time PCR assays in environmental samples. The accuracy of the eae gene-based detection method was further evaluated over time in a soil system against an activity measurement, using the bioluminescent properties of an E. coli O157:H7 Tn5luxCDABE construct. The detection of significant numbers of viable but nonculturable (VBNC) as well as nonviable and possibly physically protected cells as shown over a period of 90 days further complicates the use of real-time PCR assays for quick diagnostics in environmental samples and infers that enrichment culturing is still required for the final verification of samples found positive by real-time PCR methods.  相似文献   

7.
A total of 5590 stool samples from healthy employees in the meat industry were screened by PCR for verotoxin-producing Escherichia coli (VTEC). The PCR product of VT-encoding genes was detected in 3. 5% of the samples. Phenotypic and genotypic traits of 47 VTEC strains isolated from asymptomatic carriers were characterized. A variety of serotypes was found; one strain belonged to the serotype O157:H7. The majority of the isolates proved to be VT2-positive. Fifty-seven percent of the verotoxin-producing strains harboured the genes for one or several additional virulence associated factors, including intimin (eae, 8.5%), the 60 MDa plasmid (42.5%), enterohaemolysin (EHEC-hlyA, 38.3%), the heat-stable enterotoxin (astA, 6.4%), a serin protease (espP, 6.4%), colicin production (col D157, 12.8%) and a secretion system II (etpD, 10.6%). None of the strains was positive for a specific enzyme with catalase-peroxidase activity (katP).  相似文献   

8.
AIMS: To evaluate the suitability of a multiplex PCR-based assay for sensitive and rapid detection of Escherichia coli O157:H7 in soil and water. METHODS AND RESULTS: Soil and water samples were spiked with E. coli O157:H7 and subjected to two stages of enrichment prior to multiplex PCR. Detection sensitivities were as high as 1 cfu ml(-1) drinking water and 2 cfu g(-1) soil. Starvation of E. coli O157:H7 for 35 d prior to addition to soil did not affect the ability of the assay to detect initial cell numbers as low as 10 cfu g(-1) soil. Use of an 8-h primary enrichment enabled detection of as few as 6 cfu g(-1) soil, and 10(4) cfu g(-1) soil with a 6-h primary enrichment. When soil was inoculated with 10(5) cfu g(-1), the PCR assay indicated persistence of E. coli O157:H7 during a 35 d incubation. However, when soil was inoculated with lower numbers of pathogen, PCR amplification signals indicated survival to be dependent on cell concentration. CONCLUSIONS: A multiplex PCR-based assay, in combination with an enrichment strategy enabled sensitive and rapid detection of E. coli O157:H7 in soil and water. SIGNIFICANCE AND IMPACT OF THE STUDY: The ability to sensitively detect E.coli O157:H7 in environmental material within one working day represents a considerable advancement over alternative more time-consuming methods for detection of this pathogen.  相似文献   

9.
AIMS: To assess the presence of virulence genes in environmental and foodborne Escherichia coli isolates using the TaqMan PCR system. METHODS AND RESULTS: Three TaqMan pathogen detection kits called O157:H7, StxI and StxII were used to investigate the presence of virulence genes in Escherichia coli isolates. All 54 foodborne E. coli O157:H7 isolates showed expected results using these kits. Ninety (15%) of 604 environmental isolates gave positive amplification with an O157:H7-specific kit. TaqMan PCR amplification products from these 90 isolates were analysed by agarose gel electrophoresis, and 90% (81 of 90) of the environmental samples contained the expected PCR product. Sixty-six of these 90 were chosen for serotyping tests and only 35% (23 of 66) showed agglutination with both anti-O157 and anti-H7 antibodies. Further ribotyping of 16 sero-positive isolates in an automated Riboprinter did not identify these to be O157:H7. Multiplex PCR with primers for eaeA, stxI and stxII genes was used to confirm the TaqMan results in 10 selected environmental isolates. CONCLUSIONS: All three TaqMan pathogen detection kits were useful for virulence gene analysis of prescreened foodborne O157:H7 isolates, while the O157:H7-specific kit may not be suitable for virulence gene analysis of environmental E. coli isolates, because of high false positive identification. SIGNIFICANCE AND IMPACT OF THE STUDY: The ability to rapidly identify the presence of pathogenic E. coli in food or environmental samples is essential to avert outbreaks. These results are of importance to microbiologists seeking to use TaqMan PCR to rapidly identify pathogenic E. coli in environmental samples. Furthermore, serotyping may not be a reliable method for identification of O157:H7 strains.  相似文献   

10.
Surface water and groundwater are continuously used as sources of drinking water in many metropolitan areas of the United States. The quality of water from these sources may be reduced due to increases in contaminants such as Escherichia coli from urban and agricultural runoffs. In this study, a multiplex fluorogenic PCR assay was used to quantify E. coli O157:H7 in soil, manure, cow and calf feces, and dairy wastewater in an artificial wetland. Primers and probes were designed to amplify and quantify the Shiga-like toxin 1 (stx1) and 2 (stx2) genes and the intimin (eae) gene of E. coli O157:H7 in a single reaction. Primer specificity was confirmed with DNA from 33 E. coli O157:H7 and related strains with and without the three genes. A direct correlation was determined between the fluorescence threshold cycle (C(T)) and the starting quantity of E. coli O157:H7 DNA. A similar correlation was observed between the C(T) and number of CFU per milliliter used in the PCR assay. A detection limit of 7.9 x 10(-5) pg of E. coli O157:H7 DNA ml(-1) equivalent to approximately 6.4 x 10(3) CFU of E. coli O157:H7 ml(-1) based on plate counts was determined. Quantification of E. coli O157:H7 in soil, manure, feces, and wastewater was possible when cell numbers were >/=3.5 x 10(4) CFU g(-1). E. coli O157:H7 levels detected in wetland samples decreased by about 2 logs between wetland influents and effluents. The detection limit of the assay in soil was improved to less than 10 CFU g(-1) with a 16-h enrichment. These results indicate that the developed PCR assay is suitable for quantitative determination of E. coli O157:H7 in environmental samples and represents a considerable advancement in pathogen quantification in different ecosystems.  相似文献   

11.
Twelve ruminally cannulated cattle, adapted to forage or grain diet with or without monensin, were used to investigate the effects of diet and monensin on concentration and duration of ruminal persistence and fecal shedding of E. coli O157:H7. Cattle were ruminally inoculated with a strain of E. coli O157:H7 (10(10) CFU/animal) made resistant to nalidixic acid (Nal(r)). Ruminal and fecal samples were collected for 11 weeks, and then cattle were euthanized and necropsied and digesta from different gut locations were collected. Samples were cultured for detection and enumeration of Nal(r) E. coli O157:H7. Cattle fed forage diets were culture positive for E. coli O157:H7 in the feces for longer duration (P < 0.05) than cattle fed a grain diet. In forage-fed cattle, the duration they remained culture positive for E. coli O157:H7 was shorter (P < 0.05) when the diet included monensin. Generally, ruminal persistence of Nal(r) E. coli O157:H7 was not affected by diet or monensin. At necropsy, E. coli O157:H7 was detected in cecal and colonic digesta but not from the rumen. Our study showed that cattle fed a forage diet were culture positive longer and with higher numbers than cattle on a grain diet. Monensin supplementation decreased the duration of shedding with forage diet, and the cecum and colon were culture positive for E. coli O157:H7 more often than the rumen of cattle.  相似文献   

12.
We report here the use of immunomagnetic (IM) electrochemiluminescence (ECL) for quantitative detection of Esherichia coli O157:H7 in water samples following enrichment in minimal lactose broth (MLB). IM beads prepared in-house with four commercial anti-O157 monoclonal antibodies were compared for efficiency of cell capture. IM-ECL responses for E. coli O157:H7 (strain SEA13B88) were similar for all four commercial anti-O157 LPS monoclonal antibodies. The ECL signal was linearly correlated with E. coli O157:H7 cell concentration, indicating a constant ECL response per cell. Twenty-two strains of E. coli O157:H7 or O157:NM gave comparable ECL signals using IM beads prepared in-house. To assess the potential for interference from background bacteria in MLB-enriched water samples, 10(4) cells of E. coli O157:H7 (strain SEA13B88) were added to enriched samples prior to analysis. There was considerable variability in recovery of E. coli O157:H7 cells; net ECL signals ranged from 1% to 100% of expected values (i.e., percent inhibition from 0% to 99%). Cultures of Klebsiella pneumoniae, Klebsiella oxytoca, and Enterobacter cloacae, subsequently isolated from MLB-enriched water samples via IM separation (IMS), were observed to interfere with the binding of E. coli O157:H7 cells to IM beads. Recoveries of 10(4) E. coli O157:H7 cells were 相似文献   

13.
A circulating-flow piezoelectric biosensor, based on an Au nanoparticle amplification and verification method, was used for real-time detection of a foodborne pathogen, Escherichia coli O157:H7. A synthesized thiolated probe (Probe 1; 30-mer) specific to E. coli O157:H7 eaeA gene was immobilized onto the piezoelectric biosensor surface. Hybridization was induced by exposing the immobilized probe to the E. coli O157:H7 eaeA gene fragment (104-bp) amplified by PCR, resulting in a mass change and a consequent frequency shift of the piezoelectric biosensor. A second thiolated probe (Probe 2), complementary to the target sequence, was conjugated to the Au nanoparticles and used as a "mass enhancer" and "sequence verifier" to amplify the frequency change of the piezoelectric biosensor. The PCR products amplified from concentrations of 1.2 x 10(2) CFU/ml of E. coli O157:H7 were detectable by the piezoelectric biosensor. A linear correlation was found when the E. coli O157:H7 detected from 10(2) to 10(6) CFU/ml. The piezoelectric biosensor was able to detect targets from real food samples.  相似文献   

14.
周杨 《微生物学通报》2017,44(8):1996-2004
【目的】评价基于环介导恒温扩增技术(LAMP)的大肠杆菌O157:H7(Escherichia coli O157:H7)快速检测试剂盒的实效性。【方法】测定快速检测试剂盒的特异性、灵敏度、重复性、保质期以及运输稳定性,并与传统方法对比检测实际样品。【结果】大肠杆菌O157:H7标准菌株样品均检测为阳性,非大肠杆菌O157:H7标准菌株样品均检测为阴性,未发现有交叉反应;试剂盒最低检验限为29 CFU;该试剂盒的特异性、灵敏度及准确度与传统方法相比具有较高的一致性;试剂盒对高菌量目标菌和阴性菌样品的检测重复率均为100%,对低菌量目标菌样品的批间检测重复率为94%。试剂盒可在4°C保存9个月以上,并且可进行变温储存72 h以上。【结论】该试剂盒特异性好,灵敏度高,重复性好,储存方便,检测结果稳定、可靠,适用于对食品中大肠杆菌O157:H7的检测需求。  相似文献   

15.
In this study, enrichment procedures and two recovery methods, a membrane surface adhesion technique and an immunomagnetic separation (IMS), were compared for use in conjunction with a multiplex polymerase chain reaction (PCR) method with a view to describing a fast (24 h) and economical test for detection of Escherichia coli O157:H7 in meat samples. The study showed no significant difference between three different enrichment media (BHI, E. coli (E.C.) broth+novobiocin, modified tryptone soya broth (mTSB)+novobiocin) or two incubation temperatures (37 or 41.5 degrees C) for growth of E. coli O157:H7 in minced beef. Minced beef samples inoculated with E. coli O157:H7 at 40 cfu g(-1) were incubated at 37 degrees C for 16 h in E.C. broth+novobiocin reaching numbers of (log(10)7.82-8.70). E. coli O157:H7 were recovered by attachment to polycarbonate membranes immersed in the enriched cultures for 15 min or by immunomagnetic separation. Subsequent treatment of recovered membranes or IMS beads with lysis buffer and phenol/chloroform/isoamyl alcohol was used to extract the DNA from the extracted E. coli O157:H7 cells. The results show when E. coli O157:H7 was present at high levels in the enriched meat sample (log(10)9.6-7.5 cfu ml(-1); >16-h enrichment), the membrane and IMS techniques recovered similar levels of the pathogen and the microorganism was detectable by PCR using both methods. At lower levels of E. coli O157:H7 (log(10)6.4), only the IMS method could recover the pathogen but at levels below this neither method could recover sufficient numbers of the pathogens to allow detection. The conclusion of the study is that with sufficient enrichment time (16 h) the membrane surface adhesion membrane extraction method used in combination with multiplex PCR has the potential for a rapid and economical detection method.  相似文献   

16.
AIMS: Developing and evaluating a rapid real-time polymerase chain reaction (PCR) method for the identification of Escherichia coli O157:H7 in cattle and dairy wastewater samples produced from mozzarella cheese factories, without pre-enrichment step before DNA extraction. METHODS AND RESULTS: Wastewater samples were collected from a dairy farm producing mozzarella cheese and located in Puglia (south of Italy). Plate count and other microbial assays were performed 1 h after sampling. Wastewater samples were artificially inoculated with 10(4), 10(7) and 10(8) cells ml(-1) of E. coli O157:H7, strain EDL933. PCR protocols for stx1, stx2 and eae genes were first tested on pure DNA extracted from type strains, in order to optimize the amplification conditions and reagent concentration before real-time PCR experiments. Three specific fragments of ca 106, 150 and 200 bp corresponding to genes eae, stx1 and stx2, respectively, were obtained. Real-time PCR experiments were performed with DNA extracted from dairy and manure wastewater samples inoculated with 10(4), 10(7) and 10(8) colony-forming units (CFU) ml(-1) of E. coli O157:H7 strain EDL 933. The sensitivity limit of the assay was 10(-1) pg microl(-1) for eae, stx2 and 16SrRNA, and 1 pg microl(-1) for stx1 gene respectively. CONCLUSIONS: A real-time PCR protocol has been developed and used in order to identify potential pathogens in dairy wastewater, in which previous methods (including standard PCR) failed to work. SIGNIFICANCE AND IMPACT OF THE STUDY: Cattle and dairy wastewater samples produced from mozzarella cheese factories may harbour verocytotoxin-producing E. coli. The availability of rapid and sensitive molecular methods may be useful to monitor the persistence of verocytotoxin-producing E. coli in general and to assess the effectiveness of wastewater treatments.  相似文献   

17.
AIMS: The lack of baseline data on the prevalence of Escherichia coli O157:H7 in retail minced beef in France prompted this survey of industrial minced beef production. METHODS AND RESULTS: An automated enzyme-linked fluorescence immunoassay (ELFA), the VIDAS E. coli O157 method, was used to detect E. coli O157 in industrial minced beef samples. Confirmation of samples positive according to the ELFA was performed using an automated immunoconcentration (ICE) system, VIDAS ICE, which allows the selective capture and release of target organisms. The ICE was followed by culture on cefixime tellurite sorbitol MacConkey agar and a chromogenic medium, O157:H7 ID. Of the 3450 minced beef samples tested, 175 samples were positive with the ELFA method and, of these, four were confirmed by the ICE method. They were identified as sorbitol-negative, O157-positive, H7-positive, mobile, verotoxin-producing E. coli. CONCLUSIONS: The prevalence of E. coli O157:H7 in industrial French minced beef was 0.12%, consistent with many other reports. SIGNIFICANCE AND IMPACT OF THE STUDY: The low infective dose of E. coli O157:H7 presents a major threat. The main means of combating this organism are thermal destruction and good food hygiene covering activities on-farm, in the abattoir and in minced beef industries.  相似文献   

18.
AIMS: To evaluate PCR primers for the detection of pathogenic Escherichia coli in a real-time PCR assay and determine their utility in produce irrigation water testing. METHODS AND RESULTS: Three previously published PCR primer sets and one set designed for this study were tested for their ability to produce amplification products for several pathogenic E. coli serotypes from whole cells as template. Two of the previously published primer sets were chosen for real-time PCR detection limit determination. The coneaeA and PEH detection limit of E. coli O157:H7 was 10(0) and 10(1) CFU rxn(-1) in sterile water respectively. To detect E. coli O157:H7 in sprout irrigation water, the water required dilution due to PCR inhibitors. The detection limit of the coneaeA and PEH was 10(1) and between 10(2) and 10(3) CFU rxn(-1) in diluted sprout irrigation water respectively. CONCLUSIONS: The primer set coneaeA was able to produce an amplification product from each E. coli serotype, except O128:H7 and most sensitive for real-time PCR detection of pathogenic E. coli in diluted sprout irrigation water. SIGNIFICANCE AND IMPACT OF THE STUDY: The necessity of a dissociation analysis to distinguish positive samples from those with fluorescence of random dsDNA generation for real-time PCR in a complex background was established.  相似文献   

19.
The objective of this study was to develop and optimize a protocol for the rapid detection of Escherichia coli O157:H7 in aqueous samples by a combined immunomagnetic bead-immunoliposome (IMB/IL) fluorescence assay. The protocol consisted of the filtration or centrifugation of 30- to 100-ml samples followed by incubation of the filter membranes or pellet with anti-E. coli O157:H7 immunomagnetic beads in growth medium specific for E. coli O157:H7. The resulting E. coli O157:H7-immunomagnetic bead complexes were isolated by magnetic separation, washed, and incubated with sulforhodamine B-containing immunoliposomes specific for E. coli O157:H7; the final immunomagnetic bead-E. coli O157:H7-immunoliposome complexes were again isolated by magnetic separation, washed, and lysed with a n-octyl-beta-d-glucopyranoside to release sulforhodamine B. The final protocol took less than 8 h to complete and had a detection limit of less than 1 CFU of E. coli O157:H7 per ml in various aqueous matrices, including apple juice and cider. To validate the protocol at an independent facility, 100-ml samples of groundwater with and without E. coli O157:H7 (15 CFU) were analyzed by a public health laboratory using the optimized protocol and a standard microbiological method. While the IMB/IL fluorescence assay was able to identify E. coli O157:H7-containing samples with 100% accuracy, the standard microbiological method was unable to distinguish E. coli O157:H7-spiked samples from negative controls without further extensive workup. These results demonstrate the feasibility of using immunomagnetic beads in combination with sulforhodamine B-encapsulating immunoliposomes for the rapid detection of E. coli O157:H7 in aqueous samples.  相似文献   

20.
A virulent phage, named PP01, specific for Escherichia coli O157:H7 was isolated from swine stool sample. The phage concentration in a swine stool, estimated by plaque assay on E. coli O157:H7 EDL933, was 4.2x10(7) plaque-forming units per g sample. PP01 infects strains of E. coli O157:H7 but does not infect E. coli strains of other O-serogroups and K-12 strains. Infection of an E. coli O157:H7 culture with PP01 at a multiplicity of infection of two produced a drastic decrease of the optical density at 600 nm due to cell lysis. The further incubation of the culture for 7 h produced phage-resistant E. coli O157:H7 mutant. One PP01-resistant E. coli O157:H7 mutant had lost the major outer membrane protein OmpC. Complementation by ompC from a O157:H7 strain but not from a K-12 strain resulted in the restoration of PP01 susceptibility suggesting that the OmpC protein serves as the PP01 receptor. DNA sequences and homology analysis of two tail fiber genes, 37 and 38, responsible for the host cell recognition revealed that PP01 is a member of the T-even bacteriophages, especially the T2 family.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号