首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
A high performance liquid chromatography (HPLC) method for the estimation of pravastatin in human plasma and urine samples has been developed. The preparation of the samples was performed by automated solid phase extraction using clonazepam as internal standard. The compounds were separated by isocratic reversed-phase HPLC (C(18)) and detected at 239 nm. The method was linear up to concentrations of 200 ng/ml in plasma and 2000 ng/ml in urine. The intra-assay variability for pravastatin in plasma ranged from 0.9% to 3.5% and from 2.5% to 5.3% in urine. The inter-assay variability ranged from 9.1% to 10.2% in plasma and from 3.9% to 7.5% in urine. The validated limits of quantification were 1.9 ng/ml for plasma and 125 ng/ml for urine estimation. These method characteristics allowed the determination of the pharmacokinetic parameters of pravastatin after administration of therapeutic doses.  相似文献   

2.
An enantioseparation of the antipsychotic drug butaclamol in human plasma by high-performance liquid chromatography (HPLC) with solid phase extraction is presented. The separation was achieved on the vancomycin macrocyclic antibiotic chiral stationary phase (CSP) Chirobiotic V with a polar ionic mobile phase (PIM) consisting of methanol : glacial acetic acid : triethylamine (100:0.2:0.05, v/v/v) at a flow rate of 0.5 ml/min. The detection wavelength was 262 nm. Bond Elut C18 solid phase extraction cartridges were used in the sample preparation of butaclamol samples from plasma. The method was validated over the range of 100-3,000 ng/ml for each enantiomer concentration (R(2) > 0.999). Recoveries for (+)- and (-)-butaclamol were in the range of 94-104% at the 300-2,500 ng/ml level. The method proved to be precise (within-run precision ranged from 1.1-2.6% and between-run precision ranged from 1.9-3.2%) and accurate (within-run accuracies ranged from 1.5-5.8% and between-run accuracies ranged from 2.7-7.7%). The limit of quantitation (LOQ) and limit of detection (LOD) for each enantiomer in human plasma were 100 ng/ml and 50 ng/ml, respectively.  相似文献   

3.
An ultra-violet high-performance liquid chromatographic method was developed for the determination of sertindole, an atypical antipsychotic drug and its main metabolites dehydrosertindole and norsertindole, in human plasma. With a small sample volume, after a single-step liquid-liquid extraction, the compounds were separated on a reversed-phase XTerra RP(18) column, eluted with 45% of acetonitrile and 55% of ammonium acetate buffer (0.05 M, adjusted pH 8) and detected at 256 nm within 11 min. This method shows a good linearity for plasma concentration between 5-100 ng/ml and 100-1000 ng/ml, a good precision (inter and intra day CV < 11%) and a good inter-assay accuracy (bias < 11%). The limit of quantification concentration was 5 ng/ml. The absolute recovery of sertindole was higher than 99%. This rapid and sensitive method could be used for therapeutic drug monitoring as well as for overdose management.  相似文献   

4.
A sensitive and specific method for the simultaneous determination of the unchanged drug (solifenacin) and its major metabolite (M1, 4S-hydroxy solifenacin) in rat plasma was developed and validated. Both solifenacin and M1 were extracted from rat plasma by a two-step liquid-liquid extraction and analyzed by semi-micro HPLC with UV detection at an absorbance wavelength of 220 nm. The chromatographic separations were performed on a TSKgel ODS-80Ts (5 microm, 150 mmx2.0 mm i.d.) reversed-phase column with a mobile phase of 0.1 M phosphate buffer (pH 3.0):acetonitrile (71:29, v/v). The intra-day precision (expressed as coefficient of variation, CV) ranged from 0.4% to 1.7%, and the accuracy (expressed as relative error, RE) ranged from -5.2% to 2.0% for solifenacin. The corresponding precision ranged from 1.3% to 3.2%, and accuracy ranged from -4.0% to 8.6% for M1. The lower limit of quantitation for both solifenacin and M1 was 2 ng/ml when 1 ml of plasma was used. No endogenous interference was observed in rat plasma.  相似文献   

5.
A liquid chromatographic procedure was developed for the determination of a new antipsychotic agent ziprasidone in plasma using fluorescence detection. A one-step liquid-liquid extraction from 1 ml of alkalinized plasma containing an internal standard alpha-ergocryptine using methyl-t-butyl ether afforded a greater than 84% recovery of ziprasidone. Chromatography was performed using a reversed-phase trimethylsilyl bonded silica column with a mobile phase of 72:28 phosphate buffer:acetonitrile at a flow rate of 1.5 ml/min. Detection of the eluted peaks was observed using excitation and emission wavelengths of 320 and 410 nm, respectively. Chromatographic run time did not exceed 14 min with no interference from endogenous material. The calibration curve was linear over the concentration range of 0.5 to 200 ng/ml and the inter- and intra-assay imprecision (CV) was less than 10%. The lower limit of quantitation was assessed at 0.5 ng/ml. Specificity of the method is demonstrated by the lack of interference from a large number of commonly used drugs and their metabolites in clinical use. The utility of the method is exemplified with the presentation of clinical data from patients receiving ziprasidone.  相似文献   

6.
A sensitive and specific high-performance liquid chromatographic method with fluorescence detection (excitation wavelength: 280 nm; emission wavelength: 360 nm) was developed and validated for the determination of vinorelbine in plasma and blood samples. The sample pretreatment procedure involved two liquid–liquid extraction steps. Vinblastine served as the internal standard. The system uses a Spherisorb cyano analytical column (250×4.6 mm I.D.) packed with 5 μm diameter particles as the stationary phase and a mobile phase of acetonitrile–80 mM ammonium acetate (50:50, v/v) adjusted to pH 2.5 with hydrochloric acid. The assay showed linearity from 1 to 100 ng/ml in plasma and from 2.5 to 100 ng/ml in blood. The limits of quantitation were 1 ng/ml and 2.5 ng/ml, respectively. Precision expressed as RSD was in the range 3.9 to 20% (limit of quantitation). Accuracy ranged from 92 to 120%. Extraction recoveries from plasma and blood averaged 101 and 75%, respectively. This method was used to follow the time course of the concentration of vinorelbine in human plasma and blood samples after a 10-min infusion period of 20 mg/m2 of this drug in patients with metastatic cancer.  相似文献   

7.
The first method using high-performance liquid chromatography (HPLC) has been developed for the determination of trans-resveratrol in human plasma. The method involves a liquid–liquid extraction followed by reversed-phase HPLC with UV detection. The detection limit of trans-resveratrol in human plasma was 5.0 ng/ml. Standard curves are linear over the concentration range of 5.0–5000.0 ng/ml. Intra-assay variability ranged from 1.9 to 3.7% and inter-assay variability ranged from 2.5 to 4.0% at the concentration range of 15.0–4000.0 ng/ml.  相似文献   

8.
A method for the analysis of [1-(4-aminophenyl)-3,5-dihydro-7,8-dimethoxy-4H-2,3-benzodiazepin-4-one] (CFM-2) and its analogues CFM-3, CFM-4 and CFM-5 in rat plasma was developed. The 2,3-benzodiazepines (2,3-BZs) were extracted by liquid–liquid extraction and analyzed using high-performance liquid chromatography (HPLC) with ultraviolet detection (UV) at 240 nm. The method exhibited a large linear range from 0.05 to 2 μg/ml with an intra-assay accuracy for all studied compounds ranging from 92 to 105.5%; whereas the intra-assay precision ranged from 0.59 to 8.16% in rat plasma. The inter-assay accuracy of CFM-2, CFM-4 and their 3-methyl derivatives, CFM-3 and CFM-5 ranged from 92.2 to 107% and the inter-assay precision ranged from 2.17 to 11.9% in rat plasma. The lower limit of detection was 5.5 ng/ml for CFM-2, 6.5 ng/ml for CFM-3, 7 ng/ml for CFM-4 and 8.5 ng/ml for CFM-5 in rat plasma. The pharmacokinetic study demonstrated that 2,3-BZs achieved a peak plasma concentration between 45 and 75 min after drug administration. Moreover, we observed that plasma chromatograms of rats treated with CFM-3, CFM-4 and CFM-5, respectively, showed a peak consistent with CFM-2. Our study suggests that CFM-4, CFM-5 and CFM-3 are prodrugs of CFM-2, in which they are biotransformed in vivo via different metabolic pathways. In particular, CFM-2 has been proven to possess anticonvulsant activity in various models of seizures, acting as α-amino-3-hydroxy-5-methyl-isoxazole-4-propionate (AMPA) receptor antagonist.  相似文献   

9.
A new, simple and rapid high-performance liquid chromatography (HPLC) method with UV detection has been developed for the determination of apovincaminic acid in human plasma. Apovincaminic acid and internal standard were isolated from plasma samples by solid-phase extraction with OASIS HLB cartridges. The chromatographic separation was accomplished on a reversed-phase C(18) column and UV detection was set at 311 nm. The calibration curves were linear in the concentration range of 2.4-240.0 ng/ml, and the limits of quantification was 2.4 ng/ml. The precision and accuracy ranged from 0.84 to 8.54% and 91.5 to 108.3%, respectively. The developed method was subsequently applied to study the pharmacokinetics of apovincaminic acid in a group of 20 human subjects at a single oral dose of 10mg of vinpocetine tablet.  相似文献   

10.
A sensitive, reproducible, selective and accurate high performance liquid chromatographic (HPLC) method for the quantitative determination of 5-flurorouracil in plasma has been developed and validated using isocratic elution and UV detection. The method provides a selective quantifications of 5-flurorouracil without any interference of the endogenous uracil. The assay is performed after a double extraction of 5-flurorouracil and thymine (internal standard) from human plasma using ethyl acetate. The drug and the internal standard were eluted from a Genesis C(18) analytical column at ambient temperature with mobile phase consisting of methanol:water (10:90, v/v) adjusted to pH 3.2 with perchloric acid at a flow rate of 1.0 ml/min. The effluent was monitored with an ultraviolet detector at 260 nm. Quantification was achieved by the measurement of the peak-height ratios and the limit of quantification for 5-flurorouracil in plasma was 30 ng/ml. The retention times for 5-flurorouracil, uracil, and thymine were 4.5, 6.0, and 9.0, respectively. The intra-day coefficient of variation (CV) ranged from 1.35 to 4.53% at three different concentrations and the inter-day CVs varied from 1.29 to 4.98%. The relative and absolute recoveries varied from 96 to 101%. Stability tests showed that 5-flurorouracil is stable for at least 72 h in plasma after freezing. The simple method may permit the assessment of 5-flurorouracil plasma concentrations for pharmacokinetic studies in combination with clinical trials.  相似文献   

11.
An isocratic high-performance liquid chromatographic method with ultraviolet detection at 235 nm is described for the determination of cocaine and its metabolites benzoylecgonine, norcocaine and ecgonine methyl ester in rat plasma, collected during toxicity studies. Following simultaneous solid-phase extraction of all analytes and the internal standard tropacocaine, cocaine, benzoylecgonine and norcocaine were separated on a C18 column. Ecgonine methyl ester and cocaine were separated on coupled cyanopropyl and silica columns, following derivatization of ecgonine methyl ester to p-fluorococaine. The extraction efficiencies of these compounds from plasma ranged from 78 to 87%, while the limits of detection ranged from 35 to 90 ng/ml. The assay was linear from 300 to 5000 ng/ml, and the within-day precision 2 to 8% over this concentration range.  相似文献   

12.
A reversed-phase isocratic high-performance liquid chromatographic method has been developed for the determination of AG-331, a novel thymidylate synthase inhibitor, in human serum and urine. The method involves a solid-phase extraction from C18 cartridges without addition of an internal standard. The methanol eluent is evaporated under nitrogen at 40°C, and reconstituted in mobile phase, acetonitrile-water (35:65, v/v) containing 25 mM ammonium phosphate. Separation of AG-331 was obtained on a C18 column at a flow-rate of 1 ml/min. Chromatographic signals were monitored by a photodiode-array detector at a primary wavelength of 457 nm with a bandwidth of 4.8 nm. Standard curves are linear in the range of 22–2175 ng/ml in plasma and 44–2175 ng/ml in urine, respectively. The extraction recovery ranged from 92.9–102.4%. Intra-day coefficient of variation was less than 9.5%, and inter-day coefficient of variation was less than 14.3% for an AG-331 concentration of 44 ng/ml. This method has been used to characterize the pharmacokinetics of AG-331 in cancer patients as part of ongoing Phase I trials.  相似文献   

13.
This paper describes a relatively simple and sensitive high-performance liquid chromatographic assay (HPLC) with ultraviolet absorbance detection for 5-fluorouracil (5-FUra) and its two main metabolites, 5-fluorouridine (5-FUrd) and 5-fluoro-2′-deoxyuridine (5-FdUrd), in plasma. In this study, two plasma clean-up procedures involving addition of internal standard, solid-phase and liquid-liquid extractions have been developed. A reversed-phase Kromasil C18 column was used. The detection was performed at 268 nm for 5-FUra and at 275 nm for the two metabolites. Linear detection responses were obtained for concentrations ranging from 25 to 1000 ng/ml. The average recovery from plasma was 35, 42 and 48% for 5-FUra, 5-FUrd and 5-FdUrd, respectively. Precision, expressed as C.V., ranged from 2.7 to 13% and the mean recovery from 94 to 105%. The limits of quantitation and detection of the three analytes were 20 and 10 ng/ml, respectively. The method was used to monitor the pharmacokinetic profile of 5-FUra and its two metabolites in patients with metastatic colorectal cancer.  相似文献   

14.
A quantitative thin-layer chromatography (TLC) procedure is described for the analysis of cinromide (3-bromo-N-ethylcinnamamide) and its two major metabolites, 3-bromocinnamamide and 3-bromocinnamic acid in plasma of the dog. These compounds were recovered from acidified plasma by extraction into benzene with a recovery of 95 ± 5%. All three compounds were quantitated directly on a TLC plate by ultraviolet absorbance densitometry at 270 nm. The linear dynamic range for the quantitation of the compounds on a TLC plate ranged between 10 and 1000 ng. The complete procedure is useful in the working range of 50 ng/ml to 100 μg/ml of plasma with a coefficient of variability of about 10%. Specificity of the method for parent drug and each of its plasma metabolites was confirmed by high-performance liquid chromatography. The method was used to determine the pharmacokinetics of cinromide and its two major plasma metabolites in dogs following a single oral dose of the drug.  相似文献   

15.
A highly sensitive and specific method for the determination of josamycin in human plasma by LC–MS was developed and validated. Josamycin was extracted from human plasma by a single-step liquid–liquid extraction and analyzed by LC–MS via an electrospray ionization interface. Selected ion monitoring was used to detect josamycin and its internal standard. The intra-day precision and accuracy, expressed as C.V. and R.E., ranged from 2.8% to 13.5% and −10.3% to 7.6%, respectively. The lower limit of detection was 0.1 ng/ml and the lower limit of quantitation was set at 1 ng/ml when 0.5 ml of plasma was used. No endogenous interference was observed in human plasma obtained from drug-free volunteers.  相似文献   

16.
An HPLC assay for DMP 811, 4-ethyl-2-propyl-1-[(2′-(1H-tetrazol-5-yl)biphenyl-4-yl)-methyl]imidazole-5-carboxylic acid (I) in rat and dog plasma has been developed. Compound I was isolated from plasma using a liquid—liquid back extraction procedure. The extraction recovery was greater than 81%. Separation of I from endogenous components in plasma was achieved on an E. Merck C8 column using a mobile phase of 0.05 M ammonium acetate, brought to pH 3.75 with acetic acid, and acetonitrile (78:22, v/v). The eluent was monitored by fluorescence with excitation and emission set at 235 and 370 nm, respectively. The assay was linear from 2 to 2000 ng/ml. Inter- and intra-day coefficients of variation for the rat-plasma assay ranged from 0.9 to 5.2% (5–2000 ng/ml) and 2.7 to 16.5% (2–2000 ng/ml), respectively. The respective coefficients of variation for the dog-plasma assay were 1.9 to 5.6% and 1.2 to 14.0%. The percent differences from the accuracy results were 12% or less. Using 0.5 ml of plasma for extraction, the minimum quantifiable limit was 2 ng/ml. This method has been used to quantify plasma levels of I in rats or dogs following 3–10 mg/kg i.v. or p.o. doses.  相似文献   

17.
A high-performance liquid chromatographic method for the measurement of bumetamide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol—water—glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5–2000 ng/ml.  相似文献   

18.
A simple and sensitive high-performance liquid chromatographic (HPLC) method using ultraviolet detection was developed for the determination of testosterone in human plasma. Testosterone and the internal standard, griseofulvin, were extracted from 0.50 ml plasma sample using a mixture of dichloromethane-2,2,4-trimethylpentane (3:2, v/v). The mobile phase, consisted of 0.02 M sodium dihydrogenphosphate-acetonitrile-methanol (51:47:2, v/v) adjusted to pH 3.1 and delivered to a C(18) analytical column (150 x 4.6 mm I.D., 4 microm particles) at a flow-rate of 1 ml/min while the detection wavelength was set at 240 nm with a sensitivity range of 0.005 a.u.f.s. The method has a quantification limit of 1.6 ng/ml. Recoveries of testosterone were all greater than 92% over the linear concentration range of 1.6-400 ng/ml while that of griseofulvin was approximately 95%. The within- and between-day RSD values were all less than 8% while the accuracy values ranged from 96.0 to 106.0% over the concentration range studied. The method was applied to the analysis of early morning plasma testosterone levels of 12 healthy human male volunteers. The levels were found to range from 3.1 to 8.4 ng/ml, within the normal range reported in the literature.  相似文献   

19.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the determination of piroxicam, meloxicam and tenoxicam in human plasma was developed. Piroxicam, meloxicam, tenoxicam and isoxicam (internal standard) were extracted from human plasma with ethyl acetate at acidic pH and analyzed on a Sunfire column with the mobile phase of methanol:ammonium formate (15 mM, pH 3.0) (60:40, v/v). The analytes were detected using a mass spectrometer, equipped with electrospray ion source. The instrument was set in the multiple-reaction-monitoring (MRM) mode. The standard curve was linear (r=1.000) over the concentration range of 0.50-200 ng/ml. The coefficient of variation (CV) and relative error (RE) for intra- and inter-assay statistics at three QC levels were 1.0-5.4% and -5.9 to 2.8%, respectively. The recoveries of piroxicam, meloxicam and tenoxicam ranged from 78.3 to 87.1%, with that of isoxicam being 59.7%. The lower limit of quantification for piroxicam, meloxicam and tenoxicam was 0.50 ng/ml using a 100 microl plasma sample. This method was successfully applied to a pharmacokinetic study of piroxicam after application of transdermal piroxicam patches to humans.  相似文献   

20.
We have established a highly sensitive high-performance liquid chromatographic method for the determination of an anticancer drug, UCN-01, in human plasma or urine. Using a fluorescence detector set at an excitation wavelength of 310 nm and emission monitored at 410 nm, there was a good linearity for UCN-01 in human plasma (r=0.999) or urine (r=0.999) at concentrations ranging from 0.2 to 100 ng/ml or 1 to 400 ng/ml, respectively. For intra-day assay, in plasma samples, the precision and accuracy were 1.8% to 5.6% and −10.0% to 5.2%, respectively. For inter-day assay, the precision and accuracy were 2.0% to 18.2% and 2.4% to 10.0%, respectively. In urine samples, the intra- and inter-day precision and accuracy were within 3.9% and ±2.7%, respectively. The lower limit of quantification (LLOQ) was set at 0.2 ng/ml in plasma and 1 ng/ml in urine. UCN-01 in plasma samples was stable up to two weeks at −80°C and also up to four weeks in urine samples. This method could be very useful for studying the human pharmacokinetics of UCN-01.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号