首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatographic method was developed for the simultaneous determination of phenylbutazone and its metabolites, oxyphenbutazone and γ-hydroxyphenylbutazone, in plasma and urine. Samples were acidified with hydrochloric acid and extracted with benzene—cyclohexane (1:1, v/v). The extract was redissolved in methanol and chromatographed on a μBondapak C15 column using a mobile phase of methanol—0.01 M sodium acetate buffer (pH 4.0) in a linear gradient (50 to 100% methanol at 5%/min; flow-rate 2.0 ml/min) in a high-performance liquid chromatograph equipped with an ultra-violet absorbance detector (254 nm). The detection limit for phenylbutazone, oxyphenbutazone and for γ-hydroxyphenylbutazone was 0.05 μg/ml.A precise and sensitive assay for the determination of phenylbutazone and its metabolites was established.  相似文献   

2.
A method is described for the simultaneous determination of heroin (3, 6-diacetylmorphine, DAM) and its two active metabolites 6-acetylmorphine and morphine in blood by high-performance liquid chromatography using a normal-phase column and a UV detector at 218 nm. The compounds are stabilized in blood by rapid freezing and recovered by a multistep liquid—liquid extraction. The mobile phase is acetonitrile—methanol (75:25, v/v) buffered to apparent pH 7 with ammonium hydroxide and acetic acid. Usingl--acetylmethadol as an internal standard, UV detection and a 1-ml biofluid sample, the lower limit of sensitivity is 12.5 ng/ml. Commonly used narcotic analgesics including codeine, propoxyphene, meperidine, methadone and levorphanol do not interfere with the analysis. The method has been applied to blood samples from humans and rats. Extracts of blood from a patient who had received an intravenous dose of 14 mg of DAM contained DAM and both of its active metabolites.  相似文献   

3.
Doxepin is a tricyclic antidepressant marketed as an irrational mixture of cis- and trans-geometric isomers in the ratio of 15:85. A convenient high-performance liquid chromatographic (HPLC) procedure for simultaneous quantitation of geometric isomers of doxepin and N-desmethyldoxepin in plasma and urine is described. The HPLC procedure employed a normal phase system with a silica column and a mobile phase consisting of hexane-methanol-nonylamine (95:5:0.3, v/v/v), a UV detector and nortriptyline as the internal standard. The liquid-liquid extraction solvent was a mixture of n-pentane-isopropanol (95:5, v/v). The limit of quantitation was 1 ng/ml for each isomer. The calibration curves were linear over the ranges 1–200 ng/ml (plasma) and 1–400 ng/ml (urine). In plasma, the accuracy (mean±S.D.) (97.53±1.67%) and precision (3.89±1.65%) data for trans-doxepin were similar to corresponding values for urine, i.e., 97.10±2.40 and 3.82±1.14%. Accuracy and precision data for trans-N-desmethyldoxepin in plasma were 97.57±2.06 and 4.38±3.24%, and in urine were 97.64±3.32 and 5.26±1.83%, respectively. Stability tests under three different conditions of storage indicated no evidence of degradation. The recovery of doxepin was 61–64% from plasma and 63–68% from urine. The method has been applied to analyses of plasma and urine samples from human volunteers and animals dosed with doxepin.  相似文献   

4.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of 8-chloro-6-(2-chlorophenyl)-4H-imidazo-[1,5-a]-[1,4]-benzodiazepine-3-carboxamide [I] and its 4-hydroxy metabolite, 8-chloro-6-(2-chlorophenyl)-4-hydroxy-4H-imidazo-[1,5-a][1,4]-benzodiazepine-3-carboxamide [II] in whole blood, plasma or urine. The assay for both compounds involves extraction into diethyl ether—methylene chloride (70:30) from blood, plasma, or urine buffered to pH 9.0. The overall recoveries of [I] and [II] are 92.0 ± 5.4% (S.D.) and 90.3 ± 4.9% (S.D.), respectively. The sensitivity limit of detection is 50 ng/ml of blood, plasma, or urine using a UV detector at 254 nm. The HPLC assay was used to monitor the blood concentration—time fall-off profiles, and urinary excretion profiles in the dog following single 1 mg/kg intravenous and 5 mg/kg oral doses, and following multiple oral doses of 100 mg/kg/day of compound [I].  相似文献   

5.
A rapid high-performance liquid chromatographic method has been developed to determine piromidic acid in trout muscle tissue and in urine, in the presence of nalidixic, 7-hydroxymethylnalidixic, oxolinic and pipemidic acids and cinoxacin. A Nova-Pak C18 column was used with acetonitrile–4·10−4 M oxalic acid (40:60, v/v) as the mobile phase. A post-column change of pH was made with NaOH. Fluorimetric detection at 456 nm (λex 275 nm) was used. The instrumental detection limit was 5.91 ng/ml, based on height of peak. Pretreatment of the urine samples was not necessary and fish samples were extracted with sodium hydroxide solutions and cleaned by means of an extraction with chloroform. Detection limit was 147 ng/ml for urine and 5.91 ng/g for trout muscle. Good separation without interference from any other components was obtained. Recovery was better than 87% in urine and better than 72% in trout muscle tissue.  相似文献   

6.
A capillary electrophoresis method for the simultaneous separation and enantioseparation of the antibacterial drug ofloxacin and its metabolites desmethyl ofloxacin and ofloxacin N-oxide in human urine has been developed and validated. Enantioseparation was achieved by adding sulfobutyl β-cyclodextrin to the running buffer. The detection of the analytes was performed by laser-induced fluorescence (LIF) detection using a HeCd-laser with an excitation wavelength of 325 nm. In comparison with conventional UV detection, LIF detection provides higher sensitivity and selectivity. The separation can be performed after direct injection of urine into the capillary without any sample preparation, because no matrix compounds interfere with the assay. Additionally, the high sensitivity of this method allows the quantification of the very low concentrations of enantiomers of both metabolites. The limit of quantification was 250 ng/ml for ofloxacin enantiomers and 100 ng/ml for each metabolites’ enantiomers. This method was applied to the analysis of human urine samples collected from a volunteer after oral administration of 200 mg of (±)-ofloxacin to elucidate stereoselective differences in the formation and excretion of the metabolites. It could be demonstrated that the renal excretion of the S-configured metabolites, especially S-desmethyl ofloxacin, within the first 20 h after dosage, is significantly lower than that of the R-enantiomers.  相似文献   

7.
Ebrotidine is a new H2-receptor antagonist with powerful antisecretory activity, demonstrated gastroprotection and the ability to inhibit protease and lipase activities of Helicobacter pylori. As a tool in the clinical pharmacokinetic study of ebrotidine, an analytical method for the simultaneous determination of ebrotidine an its metabolites in human urine was developed. An ion-pair reversed-phase HPLC separation using 1-hexanesulfonic acid and acetonitrile as mobile phase with gradient elution was optimized. In addition, several procedures of preconcentration and clean-up were tested, including solid-phase and liquid—liquid extraction, the mixture dichloromethane—2-propanol (9:1, v/v) at pH 11 being the most efficient. The quality parameters of the whole analytical method were established, the calibration curves were linear over the range studied (1–200 μg/ml) and the reproducibility of the method was high (inter-day R.S.D. values lower than 4.4%).The limits of detection were between 26 and 110 ng/ml of urine for ebrotidine and its metabolites. The method was applied to the analysis of urine collected from two volunteers during 96 h following oral administration of ebrotidine at a dose of 400 mg.  相似文献   

8.
A specific and precise assay, capable of quantitating in human plasma simultaneously but separately quinidine, dihydroquinidine and the quinidine metabolites 2′-quinidinone, 3-OH-quinidine and a third metabolite found — tentatively identified as the product formed by rearrangement of quinidine-N-oxide — is reported. The assay uses a normal phase high-performance liquid chromatographic (HPLC) system with a variable-wavelength UV detector at 235 nm and has a limit of sensitivity at approximately 20 ng/ml. The mobile phase consists of hexanes—ethanol—ethanolamine (91.5:8.47:0.03). A 2-ml plasma sample is worked up by adding primaquine base as an internal standard and extracting with ether—dichloromethane—isopropanol (6:4:1). The organic extract is evaporated and the residue reconstituted in 100—600 μl of mobile phase and an aliquot injected onto the column.Comparison of this procedure with the Edgar and Sokolow (dichloroethane) extraction—fluorescence procedure and with the Cramer and Isaksson (benzene) double extraction—fluorescence assay indicates that both fluorescence procedures give quinidine concentrations up to 2.3 times those determined by HPLC. These discrepancies were shown to be due to carry-over of metabolites and some extraneous background fluorescence.  相似文献   

9.
A single-solvent extraction step high-performance liquid chromatographic method is described for quantitating midazolam and its two hydroxy metabolites in rat serum microsamples (50 μl). The separation used a 2 mm I.D. reversed-phase Symmetry C18 column with an isocratic mobile phase consisting of methanol-acetonitrile-14.9 mM sodium acetate in water at pH 3.0 (10:23:67, v/v). The detection limit was 10 ng/ml for all the compounds using an ultraviolet detector operated at 230 nm. The method was used to study the pharmacokinetics of midazolam after an intravenous bolus dose (0.75 mg/kg).  相似文献   

10.
This paper describes a precise and sensitive method for analysis of nalidixic acid and its two major metabolites in plasma and urine following the oral administration of a therapeutic dose in humans. After addition of an internal standard (oxolinic acid), 1-ml samples of plasma or urine are extracted at acidic pH with chloroform. The extracts are purified by re-extraction with sodium hydroxide solution and then chloroform. The final extracts are evaporated to dryness, reconstituted in mobile phase and injected into a high-performance liquid chromatograph equipped with RP-8 column and UV detector operating at 254 nm. The limit of sensitivity of the method is lower than 0.5 μg/ml of plasma or urine for each compound. The applicability of the method to pharmacokinetic studies of nalidixic acid in humans is demonstrated.  相似文献   

11.
A method is described for the simultaneous determination of l-α-acetylmethadol (LAAM) and its N-demethylated metabolites, l-α-noracetylmethadol (norLAAM) and l-α-dinoracetylmethadol (dinorLAAM), in plasma by gas chromatography—chemical ionization mass spectrometry. Deuterated internal standards for each analyte serve as carriers and control for recovery during sample purification on a solid-phase extraction column (C18), and subsequent separation and analysis on a DB-17 capillary column. With this method, we have determined levels of LAAM, norLAAM, and dinorLAAM in small volumes of plasma (100 μl). The limit of quantitation for all analytes was approximately 1.0 ng/g plasma and the limit of detection was approximately 0.5 ng/g plasma. An experimental application is also described where these analytes are quantitated in plasma obtained from rats before, during, and after chronic administration of LAAM-HCl. Since this technique affords a selective and sensitive means of detection of LAAM and its active, N-demethylated metabolites in small samples of blood, it may enable patient compliance to be more easily assessed by allowing samples to be collected by a simple finger-prick technique.  相似文献   

12.
A high-performance liquid chromatographic method has been developed for the determination of pipotiazine in human plasma and urine. After selective extraction, pipotiazine and the internal standard (7-methoxypipotiazine) are chromatographed on a column packed with Spherosil XOA 600 (5 μm) using a 7:3 (v/v) mixture of diisopropyl ether—isooctane (1:1, v/v) + 0.2% triethylamine and diisopropyl ether—methanol (1:1, v/v) + 0.2% triethylamine + 2.6% water. The eluted compounds are measured by fluorescence detection. The sensitivity of the method was established at 0.25 ng/ml pipotiazine in plasma and 2 ng/ml pipotiazine in urine (C.V. < 5%). The method has been successfully applied to a pharmacokinetic study following a single oral administration of 10 mg of pipotiazine.  相似文献   

13.
The performance of a number of liquid—solid systems, consisting of mixtures of buffers (0.05 M) and methanol as mobile phase and methyl-silica as stationary phase, were investigated with respect to their use in the separation of 1,4-benzodiazepines by reversed-phase high-performance liquid chromatography with UV detection at 254 nm. Phase system selectivities and column efficiencies were determined. A nomogram is presented from which the chromatographic parameters can be calculated.A complete separation of nine benzodiazepines within 12 min has been achieved, using methyl-silica as the stationary phase and 50% methanol as the eluent.The results were applied to the development of a method for the determination of therapeutic levels of diazepam and its metabolites in human serum, urine and saliva. The first step in the analysis, the extraction of diazepam and its metabolites from serum and urine, was also investigated and good recoveries were achieved. A low detection limit (0.2 ng) and high precision were obtained. The concentrations of diazepam and its metabolites in human serum, urine and saliva were determined after both single and multiple oral doses of diazepam (and oxazepam).  相似文献   

14.
A sensitive gas—liquid chromatographic technique for the quantitative analysis of SCH-12679 (d-7,8-dimethoxy-3-methyl-phenyl-2,3,4,5-tetrahydro-1H-3-benzazepine acid maleate) and its major metabolites in plasma of aggressive mental retardates receiving therapeutic doses of the medicament has been developed. The lower limits of detection are 20 ng/ml for SCH-12679, 0.5 ng/ml for 3-desmethyl SCH-12679 and 0.4 ng/ml for 7-desmethyl plus 8-desmethyl SCH-12679. SCH-12679 is estimated with a flame ionization detector. Its metabolites are quantitated using an electron-capture detector after conversion of the compounds to their heptafluorobutyryl derivatives by reaction with the appropriate anhydride. Data on plasma levels of unchanged SCH-12679, 3-desmethyl SCH-12679 and a combination of 7-desmethyl and 8-desmethyl SCH-12679 in fifteen patients treated with the medicament are presented.  相似文献   

15.
A high-performance liquid chromatographic method is described for the determination of citalopram [1-(3-(dimethylaminopropyl)-1-(4-fluorophenyl)-5-phthalancarbonitrile] and its two main metabolites (the methylamino and amino derivatives). The compounds were extracted from alkaline plasma with diethyl ether. The combined ether layers were evaporated after addition of 50 μl of 0.1 N HCl. The residual extracts were purified with diethyl ether and 20 μl were injected into a Spherisorb ODS 5-μm column with acetonitrile–0.6% phosphate buffer pH 3 (55:45, v/v) as the mobile phase. Using a fluorescence detector the detection limits are 1 ng/ml of plasma for citalopram and the methylamino metabolite and 0.5 ng/ml for the amino metabolite.  相似文献   

16.
A high-performance liquid chromatographic method for the measurement of bumetamide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol—water—glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5–2000 ng/ml.  相似文献   

17.
This study describes a new simultaneous determination of haloperidol and bromperidol and their reduced metabolites by modification of automated column-switching high-performance liquid chromatography. The test compounds were extracted from 1ml of plasma using chloroform-hexane (30:70 (v/v)), and the extract was injected into a hydrophilic metaacrylate polymer column for clean-up and a C(18) analytical column for separation. The mobile phases consisted of phosphate buffer (0.02M, pH 4.6), perchloric acid (60%) and acetonitrile (54:1:45 (v/v)) and was delivered at a flow-rate of 0.6ml/min. The peak was detected using a UV detector set at 215nm. The method was validated for the concentration range 1-100ng/ml, and good linearity (r >0.999) was confirmed. Intra-day coefficient variations (CVs) for haloperidol, reduced haloperidol, bromperidol and reduced bromperidol were less than 2.5, 3.1, 2.4 and 2.5%, respectively. Inter-day CVs for corresponding compounds were 3.9, 5.1, 2.6 and 4.4%, respectively. Relative errors ranged from -5 to 10% and mean recoveries were 96-100%. The limit of quantification was 1.0ng/m for each compound. This method shows good specificity with respect to commonly prescribed psychotropic drugs, and it could be successfully applied for pharmacokinetic studies and therapeutic drug monitoring, particularly in patients receiving both haloperidol and bromperidol.  相似文献   

18.
We have developed and validated a sensitive and selective assay for the quantification of paclitaxel and its metabolites 6α,3′-p-dihydroxypaclitaxel, 3′-p-hydroxypaclitaxel and 6α-hydroxypaclitaxel in plasma, tissue, urine and faeces specimens of mice. Tissue and faeces were homogenized (approximately 0.1–0.2 g/ml) in bovine serum albumin (40 g/I) in water, and urine was diluted (1:5, v/v) in blank human plasma. Sample pretreatment involved liquid-liquid extraction of 200–1000 μl of sample with diethyl ether followed by automated solid-phase extraction using cyano Bond Elut column. 2′-Methylpaclitaxel was used as internal standard. The overall recovery of the sample pretreatment procedure ranged from 76 ot 85%. In plasma, the lower limit of detection (LOD) and the lower limit of quantitation (LLQ) are 15 and 25 ng/ml, respectively, using 200 μl of sample. In tissues, faeces and urine the LLQs are 25–100 ng/g, 125 ng/g and 25 ng/ml, respectively, using 1000 μl (faeces: 200 μl) of homogenized or diluted sample. The concentrations in the various biological matrices, for validation procedures spiked with known amounts of the test compounds, are read from calibration curves constructed in blank human plasma in the range 25–100 000 ng/ml for paclitaxel and 25–500 ng/ml for the metabolites. The accuracy and precision of the assay fall within the generally accepted criteria for bio-analytical assays.  相似文献   

19.
A reversed-phase high-performance liquid chromatographic (HPLC) method has been validated for the quantitative determination of the three major paclitaxel metabolites (6α-hydroxypaclitaxel, 3′-p-hydroxypaclitaxel, 6α,3′-p-dihydroxypaclitaxel) in human plasma. The HPLC system consists of an APEX-octyl analytical column and acetonitrile-methanol-0.02 M ammonium acetate buffer pH 5 (AMW; 4:1:5, v/v/v) as the mobile phase. Detection is performed by UV absorbance measurement at 227 nm. The sample pretreatment of the plasma samples involves solid-phase extraction (SPE) on Cyano Bond Elut columns.The concentrations of the metabolic products could be determined by using the paclitaxel standard curve with a correction factor of 1.14 for 6α,3′-p-dihydroxypaxlitaxel. The recoveries of paclitaxel and the metabolites 6α,3′-p-dihydroxypaclitaxel, 3′-p-hydroxypaclitaxel and 6α-hydroxypaclitaxel in human plasma were 89, 78, 91 and 89%, respectively. The accuracy of the assay for the determination of paclitaxel and its metabolites varied between 95 and 97%, at a 50 ng/ml analyte concentration. The lower limit of quantitation was 10 ng/ml for both the parent drug and its metabolites.  相似文献   

20.
A HPLC–UV determination of clobazam and N-desmethylclobazam in human serum and urine is presented. After simple liquid–liquid extraction with dichloromethane the compounds and an internal standard diazepam were separated on a Supelcosil LC-8-DB column at ambient temperature under isocratic conditions using the mobile phase: CH3CN–water–0.5 M KH2PO4–H3PO4 (440:540:20:0.4, v/v and 360:580:60:0.4, v/v for serum and urine, respectively). The detection was performed at 228 nm with limits of quantification of 2 ng/ml for serum and 1 ng/ml for urine. Relative standard deviations for intra- and inter-assay precision were found below 8% for both compounds for all the tested concentrations. The described procedure may be easily adapted for several 1,4-benzodiazepines.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号