首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work presents the development and the validation of an LC–MS–MS method with atmospheric pressure chemical ionization for the quantitative determination of levamisole, an anthelmintic for veterinary use, in porcine tissue samples. A liquid–liquid back extraction procedure using hexane–isoamylalcohol (95:5, v/v) as extraction solvent was followed by a solid-phase extraction procedure using an SCX column to clean up the tissue samples. Methyllevamisole was used as the internal standard. Chromatographic separation was achieved on a LiChrospher® 60 RP-select B (5 μm) column using a mixture of 0.1 M ammonium acetate in water and acetonitrile as the mobile phase. The mass spectrometer was operated in MS–MS full scanning mode. The method was validated for the analysis of various porcine tissues: muscle, kidney, liver, fat and skin plus fat, according to the requirements defined by the European Community. Calibration graphs were prepared for all tissues and good linearity was achieved over the concentration ranges tested (r>0.99 and goodness of fit <10%). Limits of quantification of 5.0 ng/g were obtained for the analysis of levamisole in muscle, kidney, fat and skin plus fat tissues, and of 50.0 ng/g for liver analysis, which correspond in all cases to half the MRLs (maximum residue limits). Limits of detection ranged between 2 and 4 ng/g tissue. The within-day and between-day precisions (RSD, %) and the results for accuracy fell within the ranges specified. The method has been successfully used for the quantitative determination of levamisole in tissue samples from pigs medicated via drinking water. Moreover the product ion spectra of the levamisole peak in spiked and incurred tissue samples were in close agreement (based on ion ratio measurements) with those of standard solutions, indicating the worthiness of the described method for pure qualitative purposes.  相似文献   

2.
Laboratory tests can be done on the cellular or fluid portions of the blood. The use of different blood collection tubes determines the portion of the blood that can be analyzed (whole blood, plasma or serum). Laboratories involved in studying the genetic basis of human disorders rely on anticoagulated whole blood collected in EDTA-containing vacutainer as the source of DNA for genetic / genomic analysis. Because most clinical laboratories perform biochemical, serologic and viral testing as a first step in phenotypic outcome investigation, anticoagulated blood is also collected in heparin-containing tube (plasma tube). Therefore when DNA and plasma are needed for simultaneous and parallel analyses of both genomic and proteomic data, it is customary to collect blood in both EDTA and heparin tubes. If blood could be collected in a single tube and serve as a source for both plasma and DNA, that method would be considered an advancement to existing methods. The use of the compacted blood after plasma extraction represents an alternative source for genomic DNA, thus minimizing the amount of blood samples processed and reducing the number of samples required from each patient. This would ultimately save time and resources.The BD P100 blood collection system for plasma protein preservation were created as an improved method over previous plasma or serum collection tubes1, to stabilize the protein content of blood, enabling better protein biomarker discovery and proteomics experimentation from human blood. The BD P100 tubes contain 15.8 ml of spray-dried K2EDTA and a lyophilized proprietary broad spectrum cocktail of protease inhibitors to prevent coagulation and stabilize the plasma proteins. They also include a mechanical separator, which provides a physical barrier between plasma and cell pellets after centrifugation. Few methods have been devised to extract DNA from clotted blood samples collected in old plasma tubes2-4. Challenges from these methods were mainly associated with the type of separator inside the tubes (gel separator) and included difficulty in recovering the clotted blood, the inconvenience of fragmenting or dispersing the clot, and obstruction of the clot extraction by the separation gel.We present the first method that extracts and purifies genomic DNA from blood drawn in the new BD P100 tubes. We compare the quality of the DNA sample from P100 tubes to that from EDTA tubes. Our approach is simple and efficient. It involves four major steps as follows: 1) the use of a plasma BD P100 (BD Diagnostics, Sparks, MD, USA) tube with mechanical separator for blood collection, 2) the removal of the mechanical separator using a combination of sucrose and a sterile paperclip metallic hook, 3) the separation of the buffy coat layer containing the white cells and 4) the isolation of the genomic DNA from the buffy coat using a regular commercial DNA extraction kit or a similar standard protocol.  相似文献   

3.
Many of the antigen targets of adaptive immune response, recognized by B and T cells, have not been defined 1. This is particularly true in autoimmune diseases and cancer2. Our aim is to investigate the antigens recognized by human T cells in the autoimmune disease type 1 diabetes 1,3,4,5. To analyze human T-cell responses against tissue where the antigens recognized by T cells are not identified we developed a method to extract protein antigens from human tissue in a format that is compatible with functional assays 6. Previously, T-cell responses to unpurified tissue extracts could not be measured because the extraction methods yield a lysate that contained detergents that were toxic to human peripheral blood mononuclear cells. Here we describe a protocol for extracting proteins from human tissues in a format that is not toxic to human T cells. The tissue is homogenized in a mixture of butan-1-ol, acetonitrile and water (BAW). The protein concentration in the tissue extract is measured and a known mass of protein is aliquoted into tubes. After extraction, the organic solvents are removed by lyophilization. Lyophilized tissue extracts can be stored until required. For use in assays of immune function, a suspension of immune cells, in appropriate culture media, can be added directly to the lyophilized extract. Cytokine production and proliferation by PBMC, in response to extracts prepared using this method, were readily measured. Hence, our method allows the rapid preparation of human tissue lysates that can be used as a source of antigens in the analysis of T-cell responses. We suggest that this method will facilitate the analysis of adaptive immune responses to tissues in transplantation, cancer and autoimmunity.  相似文献   

4.
A novel method was developed for the determination of levamisole by electrochemiluminescence. The method was based on electrochemiluminescence signal enhancement produced by Ru(bpy)32+, which reacted with the tertiary amine group of levamisole on a platinum electrode in 12 mmol/L borate buffer (pH 9). A linear relationship between the luminous intensity and concentration of levamisole in the range 0–1 × 10–7 mol/L was obtained and the detection limit was 1.76 × 10–11 mol/L. The method is sensitive, selective, simple and convenient. The method has been successfully applied to the analysis of levamisole in serum. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
This study examines a novel sample preparation method for the determination of 11 hydroxy metabolites of polychlorinated biphenyls (PCBs) in plasma and organ tissues, followed by gas chromatography with mass spectrometric detection (GC/MS). The clean-up method was optimized to eliminate the interference matter by using a silica column and 10 mL of n-hexane/dichloromethane (4:6, v/v) as an eluent. Solid-phase and solvent extraction procedures were used for the plasma and tissues samples, respectively. Compared to C(18) and C(8) solid-phase, C(2) showed higher extraction efficiency with n-hexane as the eluent for plasma. The hydroxy-PCB extraction recoveries achieved with this combined extraction and clean-up procedure from plasma ranged from 87 to 117%, while those from tissues ranged from 82 to 111%. The linear detector responses for propyl derivatives of hydroxy-PCBs were obtained with the coefficients of determination varying from 0.992 to 0.998 in the concentration range of 0.1-20 ng mL(-1). The method detection limits ranged from 0.1 to 0.5 ng mL(-1) in 1 mL of plasma and from 0.1 to 0.5 ng g(-1) in 1g of tissues. This procedure was successfully applied to the study of 3-OH-2,3',4,4',5-PeCB in rat plasma and liver samples after intraperitoneal injection (20 mg/kg) of 2,3',4,4',5-PeCB.  相似文献   

6.
A sensitive and reliable high-performance liquid chromatographic (HPLC) method, using a solid-phase extraction (SPE), was established and validated for determination of p,p′-DDT [1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane] and its metabolite p,p′-DDE [1,1-(2,2-dichloroethanylidene)-bis(4-chlorobenzene)] in rat plasma, liver and brain. After being diluted with water, plasma, liver and brain samples were applied to a solid-phase extraction C18 cartridge. The extraction containing p,p′-DDT and p,p′-DDE from the cartridge were cleaned-up using a Florisil Sep-Pak cartridge. The samples were analyzed by HPLC using UV detection at 238 nm. The limit of detection for p,p′-DDT and p,p′-DDE was 0.1 mg kg−1 liver or brain and 0.1 mg l−1 plasma. For six replicate samples at 40, 4 and 0.2 mg kg−1, intra-day precision values were within 4.9% for plasma, 6.4% for liver, and 9.7% for brain. Inter-day precision values at 4 mg kg−1 were within 8.2% for plasma and tissues. The method performances were shown to be selective for p,p′-DDT and p,p′-DDE, and linear over the range 0.04–12 mg kg−1 (mg l−1 for plasma). The absolute recoveries of p,p′-DDT and p,p′-DDE in rat plasma and tissues were over 92%. The method was proved to be applicable to the pharmacokinetic study of DDT in rats after a single oral administration.  相似文献   

7.
Summary Auxin activity was detected in honeydew obtained from the aphid Tuberolachnus salignus (Gmelin) feeding on willow (Salix viminalis). Active uptake of 14C-indolyl-3-acetic acid (IAA) into the sieve tubes was demonstrated by irrigating the cambial surface of willow bark with 14C-IAA solution and assaying aphid stylet exudate. When, however, 14C-IAA was applied to the peridermal tissues of the bark or to a mature leaf most of the radioactivity (collected in honeydew or stylet exudate) co-chromatographed with indolyl-3-acetyl-aspartic acid (IAAsp). The presence of IAAsp in honeydew was not affected by extraction procedure or by aphid metabolism. Honeydew obtained from willow treated with 14C-tryptophan contained only 14C-tryptophan. When 14C-IAA was applied in agar to the cut end of willow segments the radioactivity was found to move in a basipetally polar manner. The direction of movement of radioactivity in the sieve tubes, however, was found to be influenced by the proximity of the roots. Nevertheless, there was evidence that endogenous auxin in the sieve tubes does move in a predominantly basipetal direction.  相似文献   

8.
A method for the determination of therapeutic levels of metoprolol in human plasma is presented. Metoprolol and the internal standard are extracted from the buffered plasma sample to an organic phase containing 4 x 10?3M phosgene. After 10 min the organic phase is taken to dryness. The residue is dissolved in ethyl acetate and the formed oxazolidine derivatives are analyzed by gas chromatography with nitrogen-selective detection. With packed columns, rectilinear standard curves through the origin were obtained down to 80 nmoles/l of plasma. The precision of the method at 200 nmoles/l was 1.5% (n = 8). The sensitivity of the method was improved by using capillary column gas chromatography. Linear standard curves were obtained down to 10 nmoles/1 of metoprolol in plasma. The precision of the method at the 50 nmoles/1 level was 2.2% (n = 7). With this simple and straightforward method using extractive derivatization 30 samples can be handled in a day.  相似文献   

9.
ExtrelutR extraction and glass capillary gas chromatography were applied to the routine determination of nicotine and its metabolites cotinine, nicotine-1′-N-oxide and cotinine-1-N-oxide in urine and plasma. After extraction of nicotine and cotinine both N-oxides and phendimetrazine-N-oxide (used as internal standard) were reduced to their bases by SO2 on-column and eluted by a mixture of diethyl ether and dichloromethane. The minimum detectable concentrations are 0.03 μg/ml for urinary nicotine and cotinine and 0.1 μg/ml for the N-oxides. In plasma samples the corresponding values are 5 ng/ml and 15 ng/ml, respectively, with sample values as small as 2 ml. The advantage of the direct determination of all four compounds of interest in one sample reduced the amount of plasma required. The straightforward and rapid extraction and reduction procedure as well as the long-term stability of the gas chromatographic separation system make the method suitable for routine application.  相似文献   

10.
The aim of this study was to establish an easy and accurate method for the determination of bisphenol-A (BPA) in the body liquid such as serum and urine. Two high-performance liquid chromatography (HPLC) systems, HPLC with electrochemical detector (ED), and HPLC with mass spectrometry (MS) using electrospray ionization (ESI) interface were used for the assay in the serum samples prepared with solid-phase extraction method. Water or EtOH at a concentration below 50% was suitable for the extraction of BPA from serum. The limit of detection of BPA was 0.2 ng ml−1 for the HPLC-ED method and 0.1 ng ml−1 for HPLC–MS. There was a good correlation between the data obtained by the two HPLC systems. BPA concentrations in healthy human serum were low (0–1.6 ng ml−1). From various commercial fetal bovine serum and sheep plasma, however, significant amounts of BPA were detected. Since no BPA was detected from sheep plasma immediately after collection, the high amounts of BPA were considered to be caused by the handling of blood during the preparation of the products after blood collection. In vitro study showed that the amount of BPA leached from polycarbonate tube into sheep plasma were 40 times larger than those into water and the leached amount of BPA depended on the temperature (37°C>20°C>5°C).  相似文献   

11.
Summary The cytochemical localization of phosphatase activity has been carried out on small and intermediate vascular bundles and contiguous tissues of the leaf ofZea mays L. Similar localization patterns were obtained with the nucleoside triphosphates ATP, CTP, GTP, ITP, and UTP, and with ADP and -GP. Reaction product (lead deposits) was observed on the plasma membrane of all cell types. It was invariably heavier on the plasma membranes of the bundle-sheath cells, vascular-parenchyma cells, and the thin-walled sieve tubes and their associated companion cells than on those of the mesophyll cells. Within the bundles, the heaviest lead deposits frequently were found on the plasma membranes of the thin-walled sieve tubes and the least amount (often lacking) on those of the thick-walled sieve tubes. Formation of reaction product was suppressed by NaF, vanadate, and molybdate but not by PCMBS (p-chloromercuribenzene sulfonic acid). The results of the substrate-specificity and inhibitor-sensitivity studies indicate that a nonspecific acid phosphatase was probably responsible for the deposition of the reaction product and not the plasma membrane H+-ATPase. These results, in addition to an evaluation of the pertinent literature, lead us to conclude that H+-ATPase activity has yet to be demonstrated unequivocally in association with the plasma membrane of phloem cells with lead precipitation procedures. Nevertheless, the differences in amounts of reaction product generally associated with the plasma membranes of the thick- and thin-walled sieve tubes of the maize leaf indicate that the two types of sieve tube differ from one another physiologically.  相似文献   

12.
A sensitive and rapid LC-MS/MS method was developed and validated for the determination of levamisole in human plasma. The assay was based on liquid-liquid extraction of analytes from human plasma with ethyl ether. Chromatographic separation was carried on an Agilent HC-C(8) column (150 mm × 4.6 mm, 5 μm) at 40°C, with a mobile phase consisting of acetonitrile-10 mM ammonium acetate (70:30, v/v), a flow rate of 0.5 mL/min and a total run time of 6 min. Detection and quantification were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 205.1→178.2 for levamisole, and m/z 296.1→264.1 for mebendazole (internal standard). The assay was linear over a concentration range of 0.1-30 ng/mL with a lower limit of quantification of 0.1 ng/mL. The coefficient of variation of the assay precision was less than 8.5%. The assay was successfully used to analyze human plasma samples in a pharmacokinetic study where levamisole was administered as a liniment.  相似文献   

13.
We report a rapid and sensitive method for separation and quantitation of free fatty acids (FFAs) in human plasma using high-performance liquid chromatography (HPLC). Two established techniques of lipid extraction were investigated and modified to achieve maximal FFA recovery in a reasonably short time period. A modified Dole extraction method exhibited greater recovery (90%) and short processing times (30 min) compared to the method of Miles et al. Reversed-phase HPLC using UV detection was used for plasma FFA separation and quantitation. Two phenacyl ester derivatives, phenacyl bromide and p-bromophenacyl bromide, were investigated in order to achieve optimal separation of individual plasma FFAs (saturated and unsaturated) with desirable detection limits. Different chromatographic parameters including column temperature, column type and elution profiles (isocratic and gradient) were tested to achieve optimal separation and recovery of fatty acids. Phenacyl bromide esters of plasma fatty acids were best resolved using an octadecylsilyl column with endcapped silanol groups. An isocratic elution method using acetonitrile–water (83:17) at 2 ml/min with UV detection at 242 nm and a column temperature of 45°C was found to optimally resolve the six major free fatty acids present in human plasma (myristic [14:0], palmitic [16:0], palmitoleic [16:1], stearic [18:0], oleic [18:1] and linoleic [18:2]), with a run time of less than 35 min and detection limits in the nmol range. The entire process including plasma extraction, pre-column derivatization, and HPLC quantitation can be completed in 90 min with plasma samples as small as 50 μl. Over a wide physiological range, plasma FFA concentrations determined using our HPLC method agree closely with measurements using established TLC–GC methods (r2≥0.95). In addition, by measuring [14C] or [3H] radioactivity in eluent fractions following HPLC separation of plasma FFA, this method can also quantitate rates of FFA turnover in vivo in human metabolic studies employing isotopic tracers of one or more fatty acids.  相似文献   

14.
A radioimmunoassay for a new anticancer drug, bruceantin, has been developed using [3H]acetylbruceantin and antibody induced by immunizing rabbits with succinylbruceantin-bovine serum albumin conjugates. [3H]Acetylbruceantin was synthesized by reacting bruceantin with [3H]acetyl anhydride. The assay is simple and reproducible. The standard curve was linear on a logit-log plot, and the lower limit of sensitivity of the assay was 1 ng/ml. Using this assay, drug levels were easily determined in tissues of experimental animals following bruceantin administration. The assay procedure does not require sample extraction for plasma, urine, and bile. Bruceantin in other tissues can be extracted quantitatively with ethanol before being measured by the radioimmunoassay.  相似文献   

15.
A method for determination of phenolic flame-retardants in human plasma utilizing solid-phase extraction (SPE) and gas chromatography with electron-capture mass spectrometric detection (GC–ECMS), has been developed. The plasma lipids were decomposed by application of concentrated sulphuric acid directly on the polystyrene–divinylbenzene SPE column. The method has been validated for 2,4,6-tribromophenol (TriBP), pentabromophenol (PeBP), tetrachlorobisphenol-A (TCBP-A) and tetrabromobisphenol-A (TBBP-A) in the concentration range 1.2–25, 0.4–40, 4–200 and 4–200 pg g−1 plasma, respectively. The average absolute recovery of the analytes ranged from 51 to 85%. Tetrabromo-o-cresol and chlorotribromobisphenol-A were found suitable as internal standards, and the average recovery of the analytes relative to the internal standards was in the range 93–107%. The repeatability of the method was in the range 4–30% relative standard deviation. The estimated detection limits of TriBP, PeBP, TCBP-A and TBBP-A were 0.3, 0.4, 3.0 and 0.8 pg g−1 plasma, respectively. The method has been used for analysis of plasma samples from potentially occupationally exposed human individuals.  相似文献   

16.
In this study a novel method to determine iodine concentrations in human breast milk was developed and validated. The iodine was analyzed by inductively coupled plasma mass spectrometry (ICPMS) following tetramethylammonium hydroxide (TMAH) extraction at 90 °C in disposable polypropylene tubes. While similar approaches have been used previously, this method adopted a shorter extraction time (1 h vs. 3 h) and used antimony (Sb) as the internal standard, which exhibited greater stability in breast milk and milk powder matrices compared to tellurium (Te). Method validation included: defining iodine linearity up to 200 μg L−1; confirming recovery of iodine from NIST 1549 milk powder. A recovery of 94–98% was also achieved for the NIST 1549 milk powder and human breast milk samples spiked with sodium iodide and thyroxine (T4) solutions. The method quantitation limit (MQL) for human breast milk was 1.6 μg L−1. The intra-assay and inter-assay coefficient of variation for the breast milk samples and NIST powder were <1% and <3.5%, respectively. NIST 1549 milk powder, human breast milk samples and calibration standards spiked with the internal standard were all stable for at least 2.5 months after extraction. The results of the validation process confirmed that this newly developed method provides greater accuracy and precision in the assessment of iodine concentrations in human breast milk than previous methods and therefore offers a more reliable approach for assessing iodine concentrations in human breast milk.  相似文献   

17.
Guaifenesin after extraction from plasma with an organic solvent can be selectively derivatized with 2,4-dichlorobenzeneboronic acid and determined by gas chromatography with electron-capture detection. The detection limit for guaifenesin was 15 ng ml−1 for a 2.0-ml plasma sample. The mass spectra of the boronate derivatives of guaifenesin and mephenesin, used as internal standard, show good molecular ions with characteristic modes of fragmentation useful for their identification.  相似文献   

18.
A simple and sensitive high-performance liquid chromatographic method has been developed to measure megazol in human plasma. The method was optimized and validated according to the Washington Concensus Conference on the Validation of Analytical Methods (V.P. Shah et al., Eur. J. Drug Metab. Pharmacokinet., 15 (1991) 249). The criteria of complete validation were specificity, linearity, precision, analytical recovery, dilution and stability. It involved extraction of the plasma with dichloromethane, followed by reversed-phase high-performance liquid chromatography using a KromasilR C8 column and UV detection at 360 nm. The retention times of the internal standard (tinidazol) and megazol were 6.10 and 9.60 min, respevtively. The standard curve was linear from 2 ng ml−1 (limit of quantification) to 2000 ng ml−1. The coefficients of variation for all the criteria of validation were less than 6%; 85 to 92% extraction efficiencies were obtained. Megazol was stable during the storage period (one month at −20°C) in plasma and for two months at 25°C in standard solution. The method was tested by measuring the plasma concentration following oral administration to rat and was shown to be suitable for pharmacokinetic studies.  相似文献   

19.
An easy, quick, simple and accurate spectrofluorimetric method was recognized and validated for evaluation of sorafenib (SOR) in pure form and biologically in plasma. Cremophor RH 40 (Cr RH 40) used for enhancing the fluorescence activity of SOR in phosphate buffer (pH 7). Cr RH 40 improved the native fluorescence of SOR remarkably in water. The fluorescence spectrum of SOR was observed at 405 nm after excitation at 265 nm. The linearity appeared to be in the range of 5 to 600 ng ml?1 for pure and from 9 to 500 ng ml?1 for plasma using the protein precipitation (ppt) method while from 10 to 500 ng ml?1 for plasma using liquid–liquid extraction method. The precisions and the accuracy of the estimated method gave satisfactory results. The recommended method was effectively applied for determination of SOR in human plasma with high recovery values. The results of some compounds that are possibly found in plasma were studied. The proposed method was also focused on real volunteers and a drug dissolution test.  相似文献   

20.
Implantable cardiovascular devices are manufactured from artificial materials (e.g. titanium (Ti), expanded polytetrafluoroethylene), which pose the risk of thromboemboli formation1,2,3. We have developed a method to line the inside surface of Ti tubes with autologous blood-derived human or porcine endothelial progenitor cells (EPCs)4. By implanting Ti tubes containing a confluent layer of porcine EPCs in the inferior vena cava (IVC) of pigs, we tested the improved biocompatibility of the cell-seeded surface in the prothrombotic environment of a large animal model and compared it to unmodified bare metal surfaces5,6,7 (Figure 1). This method can be used to endothelialize devices within minutes of implantation and test their antithrombotic function in vivo. Peripheral blood was obtained from 50 kg Yorkshire swine and its mononuclear cell fraction cultured to isolate EPCs4,8. Ti tubes (9.4 mm ID) were pre-cut into three 4.5 cm longitudinal sections and reassembled with heat-shrink tubing. A seeding device was built, which allows for slow rotation of the Ti tubes. We performed a laparotomy on the pigs and externalized the intestine and urinary bladder. Sharp and blunt dissection was used to skeletonize the IVC from its bifurcation distal to the right renal artery proximal. The Ti tubes were then filled with fluorescently-labeled autologous EPC suspension and rotated at 10 RPH x 30 min to achieve uniform cell-coating9. After administration of 100 USP/ kg heparin, both ends of the IVC and a lumbar vein were clamped. A 4 cm veinotomy was performed and the device inserted and filled with phosphate-buffered saline. As the veinotomy was closed with a 4-0 Prolene running suture, one clamp was removed to de-air the IVC. At the end of the procedure, the fascia was approximated with 0-PDS (polydioxanone suture), the subcutaneous space closed with 2-0 Vicryl and the skin stapled closed.After 3 - 21 days, pigs were euthanized, the device explanted en-block and fixed. The Ti tubes were disassembled and the inner surfaces imaged with a fluorescent microscope.We found that the bare metal Ti tubes fully occluded whereas the EPC-seeded tubes remained patent. Further, we were able to demonstrate a confluent layer of EPCs on the inside blood-contacting surface.Concluding, our technology can be used to endothelialize Ti tubes within minutes of implantation with autologous EPCs to prevent thrombosis of the device. Our surgical method allows for testing the improved biocompatibility of such modified devices with minimal blood loss and EPC-seeded surface disruption.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号