Elastic fibers are key constituents of the skin. The commonly adopted optical technique for visualizing elastic fibers in the animal skin in vivo is 2‐photon microscopy (2 PM) of autofluorescence, which typically suffers from low signal level. Here we demonstrate a new optical methodology to image elastic fibers in animal models in vivo: 3‐photon microscopy (3 PM) excited at the 1700‐nm window combining with preferential labeling of elastic fibers using sulforhodamine B (SRB). First, we demonstrate that intravenous injection of SRB can circumvent the skin barrier (encountered in topical application) and preferentially label elastic fibers, as verified by simultaneous 2 PM of both autofluorescence and SRB fluorescence from skin structures. Then through 3‐photon excitation property characterization, we show that 3‐photon fluorescence can be excited from SRB at the 1700‐nm window, and 1600‐nm excitation is most efficient according to our 3‐photon action cross section measurement. Based on these results and using our developed 1600‐nm femtosecond laser source, we finally demonstrate 3 PM of SRB‐labeled elastic fibers through the whole dermis in the mouse skin in vivo, with only 3.7‐mW optical power deposited on the skin surface. We expect our methodology will provide novel optical solution to elastic fiber research.  相似文献   

2.
This paper presents an endoscopic configuration for measurements of tissue autofluorescence using two–photon excitation and time‐correlated single photon counting detection through a double‐clad photonic crystal fiber (DC‐PCF) without pre‐chirping of laser pulses. The instrument performance was evaluated by measurements of fluorescent standard dyes, biological fluorophores (collagen and elastin), and tissue specimens (muscle, cartilage, tendon). Current results demonstrate the ability of this system to accurately retrieve the fluorescence decay profile and lifetime of these samples. This simple setup, which offers larger penetration depth than one‐photon‐based techniques, may be combined with morphology‐yielding techniques such as photoacoustic and ultrasound imaging. (© 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

3.
Superficial photothermal laser ablation (SPLA) may be useful as a therapeutic approach producing a depth of injury that is sufficient to eliminate mucosal lesion but not deep enough to induce thermal effects in deeper tissue layers. The purpose of this preliminary study is twofold: (a) to describe design steps of a fiber probe capable of delivering a tightly focused laser beam, including Monte‐Carlo‐based simulations, and (b) to complete the initial testing of the probe in a sheep esophagus model, ex vivo. The cone‐shaped (tapered) fiber tip was obtained by chemical etching of the optical fiber. A 1505 nm diode laser providing power up to 500 mW was operated in continuous wave. The successful SPLA of the sheep mucosa layer was demonstrated for various speed‐power combinations, including 300 mW laser power at a surface scanning rate of 0.5 mm/s and 450 mW laser power at a surface scanning rate of 2.0 mm/s. Upon further development, this probe may be useful for endoscopic photothermal laser ablation of the mucosa layer using relatively low laser power.  相似文献   

4.
We investigated different kinds of human ex‐vivo skin samples by combined two‐photon intrinsic fluorescence (TPE), second‐harmonic generation microscopy (SHG), fluorescence lifetime imaging microscopy (FLIM), and multispectral two‐photon emission detection (MTPE). Morphological and spectroscopic differences were found between healthy and pathological skin samples, including tumors. In particular, we examined tissue samples from normal and pathological scar tissue (keloid), and skin tumors, including basal cell carcinoma (BCC), and malignant melanoma (MM). By using combined TPE‐SHG microscopy we investigated morphological features of different skin regions. Further comparative analysis of healthy skin and neoplastic samples was performed using FLIM, and MTPE. Finally, we demonstrated the use of methyl‐aminolevulinate as a contrast agent to increase the contrast in BCC border detection. The results obtained represent further support for in‐vivo noninvasive imaging of diseased skin. (© 2008 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

5.
The use of conventional fluorescence microscopy for characterizing tissue pathological states is limited by overlapping spectra and the dependence on excitation power and fluorophore concentration. Fluorescence lifetime imaging microscopy (FLIM) can overcome these limitations due to its insensitivity to fluorophore concentration, excitation power and spectral similarity. This study investigates the diagnosis of early cervical cancer using FLIM and a neural network extreme learning machine classifier. A concurrently high sensitivity and specificity of 92.8% and 80.2%, respectively, were achieved. The results suggest that the proposed technique can be used to supplement the traditional histopathological examination of early cervical cancer. (© 2014 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

6.
We report on wide‐field time‐correlated single photon counting (TCSPC)‐based fluorescence lifetime imaging microscopy (FLIM) with lightsheet illumination. A pulsed diode laser is used for excitation, and a crossed delay line anode image intensifier, effectively a single‐photon sensitive camera, is used to record the position and arrival time of the photons with picosecond time resolution, combining low illumination intensity of microwatts with wide‐field data collection. We pair this detector with the lightsheet illumination technique, and apply it to 3D FLIM imaging of dye gradients in human cancer cell spheroids, and C. elegans.  相似文献   

7.
A two‐photon fluorescence lifetime (2P‐FLIM) microendoscope, capable of energetic metabolism imaging through the intracellular nicotinamide adenine dinucleotide (NADH) autofluorescence, at sub‐cellular resolution, is demonstrated. It exhibits readily usable characteristics such as convenient endoscope probe diameter (≈2 mm), fiber length (>5 m) and data accumulation rate (16 frames per second (fps)), leading to a FLIM refreshing rate of ≈0.1 to 1 fps depending on the sample. The spiral scanning image formation does not influence the instrument response function (IRF) characteristics of the system. Near table‐top microscope performances are achieved through a comprehensive system including a home‐designed spectro‐temporal pulse shaper and a custom air‐silica double‐clad photonic crystal fiber, which enables to reach up to 40 mW of ≈100 fs pulses @ 760 nm with a 80 MHz repetition rate. A GRadient INdex (GRIN) lens provides a lateral resolution of 0.67 μm at the focus of the fiber probe. Intracellular NADH fluorescence lifetime data are finally acquired on cultured cells at 16 fps.   相似文献   

8.
The focus of the current study was to interrogate the predictive potential of laser‐induced autofluorescence (LIAF) by objectively assessing collagen synthesis in burn wound granulation tissues ex vivo. Prior grafting, granulation tissues (20 samples) following burn injury were collected from 17 subjects of age range 18 to 60 years with patient/donor consent and the corresponding autofluorescence spectra were recorded at 325 nm He‐Cd laser (≈2 mW) excitations. The resulting endogenous collagen intensity from the above tissue samples was computed by normalizing the nicotinamide adenine dinucleotide levels. In addition, the hydroxyproline content was also estimated biochemically from the same granulation tissues. A comparative assessment of both LIAF and biochemical estimations for endogenous collagen by hydroxyproline resulted in strong positive correlation among them. The above relevant observations suggest that LIAF is equally informative as that of biochemical estimations, in evaluating endogenous collagen content in wound granulation tissues. Thus, it can be concluded that LIAF has the predictive potential, as a noninvasive objective tool to measure the endogenous collagen levels in wound biopsy tissues and provide complementary data conducive for making clinical decisions.   相似文献   

9.
Negative curvature fibre (NCF) guides light in its core by inhibiting the coupling of core and cladding modes. In this work, an NCF was designed and fabricated to transmit ultrashort optical pulses for multiphoton microscopy with low group velocity dispersion (GVD) at 800 nm. Its attenuation was measured to be <0.3 dB m–1 over the range 600–850 nm and the GVD was –180 ± 70 fs2 m–1 at 800 nm. Using an average fibre output power of ~20 mW and pulse repetition rate of 80 MHz, the NCF enabled pulses with a duration of <200 fs to be transmitted through a length of 1.5 m of fibre over a tuning range of 180 nm without the need for dispersion compensation. In a 4 m fibre, temporal and spectral pulse widths were maintained to within 10% of low power values up to the maximum fibre output power achievable with the laser system used of 278 mW at 700 nm, 808 mW at 800 nm and 420 mW at 860 nm. When coupled to a multiphoton microscope, it enabled imaging of ex vivo tissue using excitation wavelengths from 740 nm to 860 nm without any need for adjustments to the set‐up.

  相似文献   


10.
We present a clinical investigation of diffuse reflectance and time‐resolved autofluorescence spectra of skin cancer with an emphasis on basal cell carcinoma. A total of 25 patients were measured using a compact steady‐state diffuse reflectance/fluorescence spectrometer and a fibre‐optic‐coupled multispectral time‐resolved spectrofluorometer. Measurements were performed in vivo prior to surgical excision of the investigated region. Singular value decomposition was used to reduce the dimensionality of steady state diffuse reflectance and fluorescence spectra. Linear discriminant analysis was then applied to the measurements of basal cell carcinomas (BCCs) and used to predict the tissue disease state with a leave‐one‐out methodology. This approach was able to correctly diagnose 87% of the BCCs. With 445 nm excitation a decrease in the spectrally averaged fluorescence lifetime was observed between normal tissue and BCC lesions with a mean value of 886 ps. Furthermore, the fluorescence lifetime for BCCs was lower than that of the surrounding healthy tissue in all cases and statistical analysis of the data revealed that this decrease was significant (p = 0.002). (© 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

11.
A system has been developed that allows for the real‐time measurement of calcium dynamics in swimming sperm. Specifically, the ratiometric dye Indo‐I is used as a fluorescent indicator of intracellular calcium dynamics. The dual emissions are collected by a high‐sensitivity back‐illuminated CCD camera coupled to a Dual‐View imaging system. From the CCD, the images are sent to a custom developed algorithm which processes the images and outputs the calcium measurements in real‐time. Additionally, sperm velocity and position data are processed and outputted in real‐time. The velocity and position data are obtained using a separate coupled red light (>670 nm) phase contrast imaging setup that does not optically interfere with the fluorescent imaging. Using this system the effects of optical trapping on calcium dynamics was determined. Optical trapping of sperm with a decaying focused laser power of 510 mW to 3 mW over 8 seconds causes a statistically insignificant change in calcium dynamics between in‐trap and out‐of‐trap conditions. Progesterone, a calcium activator, was added and sperm were trapped under the 8 second power decay conditions. Progesterone treated sperm has a statistically higher average calcium level than untreated sperm, but shows no statistical difference between progesterone treated in‐trap and out‐of‐trap conditions. Trapping at 16 seconds at 510 mW without decay, which have been shown to decrease sperm motility, shows a statistical difference between baseline pre‐trap and in‐trap intracellular calcium levels. (© 2014 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

12.
Localization of mRNA and small RNAs (sRNAs) is important for understanding their function. Fluorescent in situ hybridization (FISH) has been used extensively in animal systems to study the localization and expression of sRNAs. However, current methods for fluorescent in situ detection of sRNA in plant tissues are less developed. Here we report a protocol (sRNA‐FISH) for efficient fluorescent detection of sRNAs in plants. This protocol is suitable for application in diverse plant species and tissue types. The use of locked nucleic acid probes and antibodies conjugated with different fluorophores allows the detection of two sRNAs in the same sample. Using this method, we have successfully detected the co‐localization of miR2275 and a 24‐nucleotide phased small interfering RNA in maize anther tapetal and archesporial cells. We describe how to overcome the common problem of the wide range of autofluorescence in embedded plant tissue using linear spectral unmixing on a laser scanning confocal microscope. For highly autofluorescent samples, we show that multi‐photon fluorescence excitation microscopy can be used to separate the target sRNA‐FISH signal from background autofluorescence. In contrast to colorimetric in situ hybridization, sRNA‐FISH signals can be imaged using super‐resolution microscopy to examine the subcellular localization of sRNAs. We detected maize miR2275 by super‐resolution structured illumination microscopy and direct stochastic optical reconstruction microscopy. In this study, we describe how we overcame the challenges of adapting FISH for imaging in plant tissue and provide a step‐by‐step sRNA‐FISH protocol for studying sRNAs at the cellular and even subcellular level.  相似文献   

13.
We introduce a simple new approach for time‐resolved multiplexed analysis of complex systems using near‐infrared (NIR) dyes, applicable to in vitro and in vivo studies. We show that fast and precise in vitro quantification of NIR fluorophores' short (subnanosecond) lifetime and stoichiometry can be done using phasor analysis, a computationally efficient and user‐friendly representation of complex fluorescence intensity decays obtained with pulsed laser excitation and time‐gated camera imaging. We apply this approach to the study of binding equilibria by Förster resonant energy transfer using two different model systems: primary/secondary antibody binding in vitro and ligand/receptor binding in cell cultures. We then extend it to dynamic imaging of the pharmacokinetics of transferrin engagement with the transferrin receptor in live mice, elucidating the kinetics of differential transferrin accumulation in specific organs, straightforwardly differentiating specific from nonspecific binding. Our method, implemented in a freely‐available software, has the advantage of time‐resolved NIR imaging, including better tissue penetration and background‐free imaging, but simplifies and considerably speeds up data processing and interpretation, while remaining quantitative. These advances make this method attractive and of broad applicability for in vitro and in vivo molecular imaging and could be extended to applications as diverse as image‐guided surgery or optical tomography.   相似文献   

14.
One‐photon absorption based traditional laser treatment may not necessarily be selective at the microscopic level, thus could result in un‐intended tissue damage. Our objective is to test whether two‐photon absorption (TPA) could provide highly targeted tissue alteration of specific region of interest without damaging surrounding tissues. TPA based laser treatments (785 nm, 140 fs pulse width, 90 MHz) were performed on ex vivo mouse skin using different average power levels and irradiation times. Reflectance confocal microscopy (RCM) and combined second‐harmonic‐generation (SHG) and two‐photon fluorescence (TPF) imaging channels were used to image before, during, and after each laser treatment. The skin was fixed, sectioned and H & E stained after each experiment for histological assessment of tissue alterations and for comparison with the non‐invasive imaging assessments. Localized destruction of dermal fibers was observed without discernible epidermal damage on both RCM and SHG + TPF images for all the experiments. RCM and SHG + TPF images correlated well with conventional histological examination. This work demonstrated that TPA‐based light treatment provides highly localized intradermal tissue alteration. With further studies on optimizing laser treatment parameters, this two‐photon absorption photothermolysis method could potentially be applied in clinical dermatology. (© 2014 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

15.
Fluorescence Lifetime Imaging (FLIM) is an attractive microscopy method in the life sciences, yielding information on the sample otherwise unavailable through intensity‐based techniques. A novel Noise‐Corrected Principal Component Analysis (NC‐PCA) method for time‐domain FLIM data is presented here. The presence and distribution of distinct microenvironments are identified at lower photon counts than previously reported, without requiring prior knowledge of their number or of the dye's decay kinetics. A noise correction based on the Poisson statistics inherent to Time‐Correlated Single Photon Counting is incorporated. The approach is validated using simulated data, and further applied to experimental FLIM data of HeLa cells stained with membrane dye di‐4‐ANEPPDHQ. Two distinct lipid phases were resolved in the cell membranes, and the modification of the order parameters of the plasma membrane during cholesterol depletion was also detected.

Noise‐corrected Principal Component Analysis of FLIM data resolves distinct microenvironments in cell membranes of live HeLa cells.  相似文献   


16.
Two‐photon imaging is a noninvasive imaging technique with increasing importance in the biological and medical fields since it allows intratissue cell imaging with high resolution. We demonstrate the feasibility of using a single 2‐photon instrument to evaluate the cornea, the crystalline lens and the retina based on their autofluorescence (AF). Image acquisition was performed using a custom‐built 2‐photon microscope for 5‐dimensional microscopy with a near infrared broadband sub‐15 femtosecond laser centered at 800 nanometers. Signals were detected using a spectral photomultiplier tube. The spectral ranges for the analysis of each tissue/layer AF were determined based on the spectra of each tissue as well as of pure endogenous fluorophores. The cornea, lens and retina are characterized at multiple depths with subcellular resolution based on their morphology and AF lifetime. Additionally, the AF lifetime of NAD(P)H was used to assess the metabolic activity of the cornea epithelium, endothelium and keratocytes. The feasibility to evaluate the metabolic activity of lens epithelial cells was also demonstrated, which may be used to further investigate the pathogenesis of cataracts. The results illustrate the potential of multimodal multiphoton imaging as a novel ophthalmologic technique as well as its potential as a diagnostic tool.   相似文献   

17.
Fluorescence lifetime imaging microscopy (FLIM) is a technique that visualizes the excited state kinetics of fluorescence molecules with the spatial resolution of a fluorescence microscope. We present a scanningless implementation of FLIM based on a time- and space-correlated single photon counting (TSCSPC) method employing a position-sensitive quadrant anode detector and wide-field illumination. The standard time-correlated photon counting approach leads to picosecond temporal resolution, making it possible to resolve complex fluorescence decays. This allows parallel acquisition of time-resolved images of biological samples under minimally invasive low-excitation conditions (<10mW/cm2). In this way unwanted photochemical reactions induced by high excitation intensities and distorting the decay kinetics are avoided. Comparably low excitation intensities are practically impossible to achieve with a conventional laser scanning microscope, where focusing of the excitation beam into a tight spot is required. Therefore, wide-field FLIM permits to study Photosystem II (PS II) in a way so far not possible with a laser scanning microscope. The potential of the wide-field TSCSPC method is demonstrated by presenting FLIM measurements of the fluorescence dynamics of photosynthetic systems in living cells of the chlorophyll d-containing cyanobacterium Acaryochloris marina.  相似文献   

18.
Widefield frequency‐domain fluorescence lifetime imaging microscopy (FD‐FLIM) measures the fluorescence lifetime of entire images in a fast and efficient manner. We report a widefield FD‐FLIM system based on a complementary metal‐oxide semiconductor camera equipped with two‐tap true correlated double sampling lock‐in pixels and lateral electric field charge modulators. Owing to the fast intrinsic response and modulation of the camera, our system allows parallel multifrequency FLIM in one measurement via fast Fourier transform. We demonstrate that at a fundamental frequency of 20 MHz, 31‐harmonics can be measured with 64 phase images per laser repetition period. As a proof of principle, we analyzed cells transfected with Cerulean and with a construct of Cerulean‐Venus that shows Förster Resonance Energy Transfer at different modulation frequencies. We also tracked the temperature change of living cells via the fluorescence lifetime of Rhodamine B at different frequencies. These results indicate that our widefield multifrequency FD‐FLIM system is a valuable tool in the biomedical field.   相似文献   

19.
Multiphoton action cross‐sections are the prerequisite for excitation light selection. At the 1700‐nm window suitable for deep‐tissue imaging, wavelength‐dependent 3‐photon action cross‐sections ησ3 for RFPs are unknown, preventing wavelength selection. Here we demonstrate: (1) ex vivo measurement of wavelength‐dependent ησ3 for purified RFPs; (2) a multiphoton imaging guided measurement system for in vivo measurement; and (3) in vivo measurement of wavelength‐dependent ησ3 in RFP labeled cells. These fundamental results will provide guidelines for excitation wavelength selection for 3‐photon fluorescence imaging of RFPs at the 1700‐nm window, and augment the existing database of multiphoton action cross‐sections for fluorophores.   相似文献   

20.
Power densities and oxidation–reduction potentials (ORPs) of MFCs containing a pure culture of Shewanella oneidensis MR‐1 were compared to mixed cultures (wastewater inoculum) in cube shaped, 1‐, 2‐, and 3‐bottle batch‐fed MFC reactor configurations. The reactor architecture influenced the relative power produced by the different inocula, with the mixed culture generating 68–480% more power than MR‐1 in each MFC configuration. The mixed culture produced the maximum power density of 858 ± 9 mW m?2 in the cubic MFC, while MR‐1 produced 148 ± 20 mW m?2. The higher power by the mixed culture was primarily a result of lower internal resistances than those produced by the pure culture. Power was a direct function of ohmic resistance for the mixed culture, but not for strain MR‐1. ORP of the anode compartment varied with reactor configuration and inoculum, and it was always negative during maximum power production but it did not vary in proportion to power output. The ORP varied primarily at the end of the cycle when substrate was depleted, with a change from a reductive environment during maximum power production (approximately ?175 mV for mixed and approximately ?210 mV for MR‐1 in cubic MFCs), to an oxidative environment at the end of the batch cycle (~250 mV for mixed and ~300 mV for MR‐1). Mixed cultures produced more power than MR‐1 MFCs even though their redox potential was less negative. These results demonstrate that differences between power densities produced by pure and mixed cultures depend on the MFC architecture. Biotechnol. Bioeng. 2010; 105: 489–498. © 2009 Wiley Periodicals, Inc.  相似文献   