共查询到20条相似文献,搜索用时 15 毫秒
1.
Aneesh Alex Jessika Weingast Martin Weinigel Marcel Kellner‐Höfer Romina Nemecek Michael Binder Hubert Pehamberger Karsten König Wolfgang Drexler 《Journal of biophotonics》2013,6(4):352-362
A preliminary clinical trial using state‐of‐the‐art multiphoton tomography (MPT) and optical coherence tomography (OCT) for three‐dimensional (3D) multimodal in vivo imaging of normal skin, nevi, scars and pathologic skin lesions has been conducted. MPT enabled visualization of sub‐cellular details with axial and transverse resolutions of <2 μm and <0.5 μm, respectively, from a volume of 0.35 × 0.35 × 0.2 mm3 at a frame rate of 0.14 Hz (512 × 512 pixels). State‐of‐the‐art OCT, operating at a center wavelength of 1300 nm, was capable of acquiring 3D images depicting the layered architecture of skin with axial and transverse resolutions ~8 μm and ~20 μm, respectively, from a volume of 7 × 3.5 × 1.5 mm3 at a frame rate of 46 Hz (1024 × 1024 pixels). This study demonstrates the clinical diagnostic potential of MPT/OCT for pre‐screening relatively large areas of skin using 3D OCT to identify suspicious regions at microscopic level and subsequently using high resolution MPT to obtain zoomed in, sub‐cellular level information of the respective regions (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim) 相似文献
2.
We propose a cross‐scanning optical coherence tomography (CS‐OCT) system to correct eye motion artifacts in OCT angiography images. This system employs a dual‐illumination configuration with two orthogonally polarized beams, each of which simultaneously perform raster scanning in perpendicular direction with each other over the same area. In the reference arm, a polarization delay unit is used to acquire the two orthogonally polarized interferograms with a single photo detector by introducing different optical delay lines. The two cross‐scanned volume data are affected by the same eye motion but in two orthogonal directions. We developed a motion correction algorithm, which removes artifacts in the slow axis of each angiogram using the other and merges them through a nonrigid registration algorithm. In this manner, we obtained a motion‐corrected angiogram within a single volume scanning time without additional eye‐tracking devices. 相似文献
3.
Measuring polarization changes in the human outer retina with polarization‐sensitive optical coherence tomography 下载免费PDF全文
Barry Cense Donald T. Miller Brett J. King Thomas Theelen Ann E. Elsner 《Journal of biophotonics》2018,11(5)
Morphological changes in the outer retina such as drusen are established biomarkers to diagnose age‐related macular degeneration. However, earlier diagnosis might be possible by taking advantage of more subtle changes that accompany tissues that bear polarization‐altering properties. To test this hypothesis, we developed a method based on polarization‐sensitive optical coherence tomography with which volumetric data sets of the macula were obtained from 10 young (<25 years) and 10 older (>54 years) subjects. All young subjects and 5 of the older subjects had retardance values induced by the retinal pigment epithelium and Bruch's membrane (RPE‐BM) complex that were just above the noise floor measurement (5°‐13° at 840 nm). In contrast, elevated retardance, up to 180°, was observed in the other 5 older subjects. Analysis of the degree of polarization uniformity (DOPU) demonstrates that reduced DOPU (<0.4) in the RPE is associated with elevated double pass phase retardation (DPPR) below the RPE‐BM complex, suggesting that the observed elevated DPPR in older subjects is the result of increased scattering or polarization scrambling. Collectively, our measurements show that the outer retina can undergo dramatic change in its polarization properties with age, and in some cases still retain its clinically normal appearance. 相似文献
4.
Recent studies have demonstrated that extended imaging depth can be achieved using dual‐axis optical coherence tomography (DA‐OCT). By illuminating and collecting at an oblique angle, multiple forward scattered photons from large probing depths are preferentially detected. However, the mechanism behind the enhancement of imaging depth needs further illumination. Here, the signal of a DA‐OCT system is studied using a Monte Carlo simulation. We modeled light transport in tissue and recorded the spatial and angular distribution of photons exiting the tissue surface. Results indicate that the spatial separation and offset angle created by the non‐telecentric scanning configuration promote the collection of more deeply propagating photons than conventional on‐axis OCT. 相似文献
5.
Elmira Jalilian Qiuyun Xu Luke Horton Audrey Fotouhi Shriya Reddy Rayyan Manwar Steven Daveluy Darius Mehregan Juri Gelovani Kamran Avanaki 《Journal of biophotonics》2020,13(5)
Optical coherence tomography (OCT), with a high‐spatial resolution (<10 microns), intermediate penetration depth (~1.5 mm) and volumetric imaging capability is a great candidate to be used as a diagnostic‐assistant modality in dermatology. At this time, the accuracy of OCT for melanoma detection is lower than anticipated. In this letter, we studied for the first time, the use of a novel contrast agent consist of ultra‐small nanoparticles conjugated to a melanoma biomarker to improve the accuracy of OCT for differentiation of melanoma cells from nonmelanoma cells, in vitro. We call this approach SMall nanoparticle Aggregation‐enhanced Radiomics of Tumor (SMART)‐OCT imaging. This initial proof of concept study is the first step toward the broad utilization of this method for high accuracy all types of tumor detection applications. 相似文献
6.
Lars Kirsten Maria Gaertner Christian Schnabel Sven Meissner Edmund Koch 《Journal of biophotonics》2013,6(2):148-152
The investigation of lung dynamics on alveolar scale is crucial for the understanding and treatment of lung diseases, such as acute lung injury and ventilator induced lung injury, and to promote the development of protective ventilation strategies. One approach to this is the establishment of numerical simulations of lung tissue mechanics where detailed knowledge about three‐dimensional alveolar structure changes during the ventilation cycle is required. We suggest four‐dimensional optical coherence tomography (OCT) imaging as a promising modality for visualizing the structural dynamics of single alveoli in subpleural lung tissue with high temporal resolution using a mouse model. A high‐speed OCT setup based on Fourier domain mode locked laser technology facilitated the acquisition of alveolar structures without noticeable motion artifacts at a rate of 17 three‐dimensional stacks per ventilation cycle. The four‐dimensional information, acquired in one single ventilation cycle, allowed calculating the volume‐pressure curve and the alveolar compliance for single alveoli. (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim) 相似文献
7.
K‐distribution three‐dimensional mapping of biological tissues in optical coherence tomography 下载免费PDF全文
Probability density function (PDF) analysis with K‐distribution model of optical coherence tomography (OCT) intensity signals has previously yielded a good representation of the average number of scatterers in a coherence volume for microspheres‐in‐water systems, and has shown initial promise for biological tissue characterization. In this work, we extend these previous findings, based on single point M‐mode or two‐dimenstional slice analysis, to full three‐dimensional (3D) imaging maps of the shape parameter α of the K‐distribution PDF. After selecting a suitably sized 3D evaluation window, and verifying methodology in phantoms, the resultant parametric α images obtained in different animal tissues (rat liver and brain) show new contrasting ability not seen in conventional OCT intensity images. 相似文献
8.
A compact high‐speed full‐field optical coherence microscope has been developed for high‐resolution in vivo imaging of biological tissues. The interferometer, in the Linnik configuration, has a size of 11 × 11 × 5 cm3 and a weight of 210 g. Full‐field illumination with low‐coherence light is achieved with a high‐brightness broadband light‐emitting diode. High‐speed full‐field detection is achieved by using part of the image sensor of a high‐dynamic range CMOS camera. En face tomographic images are acquired at a rate of 50 Hz, with an integration time of 0.9 ms. The image spatial resolution is 0.9 μm × 1.2 μm (axial × transverse), over a field of view of 245 × 245 μm2. Images of human skin, revealing in‐depth cellular‐level structures, were obtained in vivo and in real‐time without the need for stabilization of the subject. The system can image larger fields, up to 1 × 1 mm2, but at a reduced depth. 相似文献
9.
High‐intensity‐focused ultrasound and phase‐sensitive optical coherence tomography for high resolution surface acoustic wave elastography 下载免费PDF全文
Elastography has the ability of quantitatively evaluating the mechanical properties of soft tissue; thus it is helpful for diagnosis and treatment monitoring of many diseases, for example, skin diseases. Surface acoustic waves (SAWs) have been proven to be a non‐invasive, non‐destructive method for accurate characterization of tissue elastic properties. Current SAW elastography using high‐energy laser pulse or mechanical shaker still have some problems. In order to improve SAW elastography in medical application, a new technique was proposed in this paper, which combines high‐intensity‐focused ultrasound as a SAWs impulse inducer and phase‐sensitive optical coherence tomography as a SAWs detector. A 2% agar‐agar phantom and ex‐vivo porcine skin were tested. The data were processed by a new algorithm based on the Fourier analysis. The results show that the proposed method has the capability of quantifying the elastic properties of soft tissue‐mimicking materials. The lateral resolution of the elastogram has been significantly improved and the different layers in heterogeneous material could also been distinguished. Our improved technique of SAW elastography has a large potential to be widely applied in clinical use for skin disease diagnosis and treatment monitoring. 相似文献
10.
Flexible wide‐field optical micro‐angiography based on Fourier‐domain multiplexed dual‐beam swept source optical coherence tomography 下载免费PDF全文
Wide‐field optical coherence tomography angiography (OCTA) is gaining interest in clinical imaging applications. In this pursuit, it is challenging to maintain the imaging resolution and sensitivity throughout the wide field of view (FoV). Here, we propose a novel method/system of dual‐beam arrangement and Fourier‐domain multiplexing to achieve wide‐field OCTA when imaging the uneven surface samples. The proposed system provides 2 separate FoVs, with flexibility that the imaging area, focus of the imaging beam and imaging depth range can be individually adjusted for each FoV, leading to either (1) increased system imaging FoV or (2) capability of targeting 2 regions of interests that locate at depths with large difference between each other. We demonstrate this novel method by employing 100 kHz laser source in a swept source OCTA to achieve an effective 200 kHz sweeping rate, covering a 22 × 22 mm FoV. The results are verified by a SS‐OCTA system employing a 200 kHz laser source, together with the experimental demonstrations when imaging whole brain vasculature in rodent models and skin blood perfusion in human fingers, show‐casing the capability of proposed system to image live large samples with complex surface topography. 相似文献
11.
Jianlong Yang Rahul Chandwani Rui Zhao Zhuo Wang Yali Jia David Huang Gangjun Liu 《Journal of biophotonics》2018,11(3)
A polarization‐multiplexed, dual‐beam setup is proposed to expand the field of view (FOV) for a swept source optical coherence tomography angiography (OCTA) system. This method used a Wollaston prism to split sample path light into 2 orthogonal‐polarized beams. This allowed 2 beams to shine on the cornea at an angle separation of ~14°, which led to a separation of ~4.2 mm on the retina. A 3‐mm glass plate was inserted into one of the beam paths to set a constant path length difference between the 2 polarized beams so the interferogram from the 2 beams are coded at different frequency bands. The resulting OCTA images from the 2 beams were coded with a depth separation of ~2 mm. A total of 5 × 5 mm2 angiograms from the 2 beams were obtained simultaneously in 4 seconds. The 2 angiograms then were montaged to get a wider FOV of ~5 × 9.2 mm2. 相似文献
12.
Multicontrast endomyocardial imaging by single‐channel high‐resolution cross‐polarization optical coherence tomography 下载免费PDF全文
Xinwen Yao Yu Gan Yuye Ling Charles C. Marboe Christine P. Hendon 《Journal of biophotonics》2018,11(4)
A single‐channel high‐resolution cross‐polarization (CP) optical coherence tomography (OCT) system is presented for multicontrast imaging of human myocardium in one‐shot measurement. The intensity and functional contrasts, including the ratio between the cross‐ and co‐polarization channels as well as the cumulative retardation, are reconstructed from the CP‐OCT readout. By comparing the CP‐OCT results with histological analysis, it is shown that the system can successfully delineate microstructures in the myocardium and differentiate the fibrotic myocardium from normal or ablated myocardium based on the functional contrasts provided by the CP‐OCT system. The feasibility of using A‐line profiles from the 2 orthogonal polarization channels to identify fibrotic myocardium, normal myocardium and ablated lesion is also discussed. 相似文献
13.
K. Divakar Rao Aneesh Alex Yogesh Verma Sreeja Thampi Pradeep K. Gupta 《Journal of biophotonics》2009,2(5):288-291
We report noninvasive imaging of the brain of adult Zebrafish (Danio rerio) using real time optical coherence tomography (OCT) capable of acquiring cross sectional 2D OCT images @ 8 frames/sec. Anatomic features such as telencephalon, tectum opticum, eminentia Granularis and cerebellum were clearly resolved in the OCT images. A 3D model of Zebrafish brain was reconstructed, for the first time to our knowledge, using these 2D OCT images. (© 2009 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim) 相似文献
14.
Oscar Carrasco‐Zevallos Ryan L. Shelton Wihan Kim Jeremy Pearson Brian E. Applegate 《Journal of biophotonics》2015,8(1-2):25-35
Currently, optical coherence tomography (OCT), is not capable of obtaining molecular information often crucial for identification of disease. To enable molecular imaging with OCT, we have further developed a technique that harnesses transient changes in light absorption in the sample to garner molecular information. A Fourier‐domain Pump‐Probe OCT (PPOCT) system utilizing a 532 nm pump and 830 nm probe has been developed for imaging hemoglobin. Methylene blue, a biological dye with well‐know photophysics, was used to characterize the system before investigating the origin of the hemoglobin PPOCT signal. The first in vivo PPOCT images were recorded of the vasculature in Xenopus laevis. The technique was shown to work equally well in flowing and nonflowing vessels. Furthermore, PPOCT was compared with other OCT extensions which require flow, such as Doppler OCT and phase‐variance OCT. PPOCT was shown to better delineate tortuous vessels, where nodes often restrict Doppler and phase‐variance reconstruction. (© 2013 WILEY‐VCH Verlag GmbH &Co. KGaA, Weinheim) 相似文献
15.
Quantitative and rapid estimations of human sub‐surface skin mass using ultra‐high‐resolution spectral domain optical coherence tomography 下载免费PDF全文
Non‐invasive and quantitative estimations for the delineation of sub‐surface tumor margins could greatly aid in the early detection and monitoring of the morphological appearances of tumor growth, ensure complete tumor excision without the unnecessary sacrifice of healthy tissue, and facilitate post‐operative follow‐up for recurrence. In this study, a high‐speed, non‐invasive, and ultra‐high‐resolution spectral domain optical coherence tomography (UHR‐SDOCT) imaging platform was developed for the quantitative measurement of human sub‐surface skin mass. With a proposed robust, semi‐automatic analysis, the system can rapidly quantify lesion area and shape regularity by an en‐face‐oriented algorithm. Various sizes of nylon sutures embedded in pork skin were used first as a phantom to verify the accuracy of our algorithm, and then in vivo, feasibility was proven using benign human angiomas and pigmented nevi. Clinically, this is the first step towards an automated skin lesion measurement system.
16.
Spectrally encoded coherence tomography and reflectometry: Simultaneous en face and cross‐sectional imaging at 2 gigapixels per second 下载免费PDF全文
Non‐invasive biological imaging is crucial for understanding in vivo structure and function. Optical coherence tomography (OCT) and reflectance confocal microscopy are two of the most widely used optical modalities for exogenous contrast‐free, high‐resolution, three‐dimensional imaging in non‐fluorescent scattering tissues. However, sample motion remains a critical barrier to raster‐scanned acquisition and reconstruction of wide‐field anatomically accurate volumetric datasets. We introduce spectrally encoded coherence tomography and reflectometry (SECTR), a high‐speed, multimodality system for simultaneous OCT and spectrally encoded reflectance (SER) imaging. SECTR utilizes a robust system design consisting of shared optical relays, scanning mirrors, swept laser and digitizer to achieve the fastest reported in vivo multimodal imaging rate of 2 gigapixels per second. Our optical design and acquisition scheme enable spatiotemporally co‐registered acquisition of OCT cross‐sections simultaneously with en face SER images for multivolumetric mosaicking. Complementary axial and lateral translation and rotation are extracted from OCT and SER data, respectively, for full volumetric estimation of sample motion with micron spatial and millisecond temporal resolution. 相似文献
17.
Arash Dadkhah Dhruba Paudel Shuliang Jiao 《Experimental biology and medicine (Maywood, N.J.)》2021,246(20):2207
Optical coherence tomography angiography (OCTA) is a functional extension of optical coherence tomography for non-invasive in vivo three-dimensional imaging of the microvasculature of biological tissues. Several algorithms have been developed to construct OCTA images from the measured optical coherence tomography signals. In this study, we compared the performance of three OCTA algorithms that are based on the variance of phase, amplitude, and the complex representations of the optical coherence tomography signals for rodent retinal imaging, namely the phase variance, improved speckle contrast, and optical microangiography. The performance of the different algorithms was evaluated by comparing the quality of the OCTA images regarding how well the vasculature network can be resolved. Quantities that are widely used in ophthalmic studies including blood vessel density, vessel diameter index, vessel perimeter index, vessel complexity index were also compared. Results showed that both the improved speckle contrast and optical microangiography algorithms are more robust than phase variance, and they can reveal similar vasculature features while there are statistical differences in the calculated quantities. 相似文献
18.
Optical coherence Doppler tomography (ODT) increasingly attracts attention because of its unprecedented advantages with respect to high contrast, capillary‐level resolution and flow speed quantification. However, the trade‐off between the signal‐to‐noise ratio of ODT images and A‐scan sampling density significantly slows down the imaging speed, constraining its clinical applications. To accelerate ODT imaging, a deep‐learning‐based approach is proposed to suppress the overwhelming phase noise from low‐sampling density. To handle the issue of limited paired training datasets, a generative adversarial network is performed to implicitly learn the distribution underlying Doppler phase noise and to generate the synthetic data. Then a 3D based convolutional neural network is trained and applied for the image denoising. We demonstrate this approach outperforms traditional denoise methods in noise reduction and image details preservation, enabling high speed ODT imaging with low A‐scan sampling density. 相似文献
19.
Kaiyan Li Wenxuan Liang Jessica Mavadia‐Shukla Hyeon‐Cheol Park Dawei Li Wu Yuan Suiren Wan Xingde Li 《Journal of biophotonics》2019,12(3)
Endoscopic optical coherence tomography (OCT) is a noninvasive technology allowing for imaging of tissue microanatomies of luminal organs in real time. Conventional endoscopic OCT operates at 1300 nm wavelength region with a suboptimal axial resolution limited to 8‐20 μm. In this paper, we present the first ultrahigh‐resolution tethered OCT capsule operating at 800 nm and offering about 3‐ to 4‐fold improvement of axial resolution (plus enhanced imaging contrast). The capsule uses diffractive optics to manage chromatic aberration over a full ~200 nm spectral bandwidth centering around 830 nm, enabling to achieve super‐achromaticity and an axial resolution of ~2.6 μm in air. The performance of the OCT capsule is demonstrated by volumetric imaging of swine esophagus ex vivo and sheep esophagus in vivo, where fine anatomic structures including the sub‐epithelial layers are clearly identified. The ultrahigh resolution and excellent imaging contrast at 800 nm of the tethered capsule suggest the potential of the technology as an enabling tool for surveillance of early esophageal diseases on awake patients without the need for sedation. 相似文献
20.
Enrico Borrelli Riccardo Sacconi Lea Querques Marco Battista Francesco Bandello Giuseppe Querques 《Journal of biophotonics》2020,13(10)
We applied three‐dimensional (3D) analysis to optical coherence tomography angiography (OCTA) to measure macular ischemia in eyes affected by non‐proliferative diabetic retinopathy (DR). A previously validated algorithm was applied to OCTA data in order to obtain 3D visualization of the retinal vasculature. Successively, a global thresholding algorithm was applied and two novel quantitative metrics were introduced: 3D vascular volume and 3D perfusion density. Two‐dimensional (2D) OCTA metrics were also obtained with different binarization thresholds for comparison. Of the 30 patients included, 15 were diagnosed with DR and 15 were controls. The 3D vascular volume and 3D perfusion density were reduced in DR eyes (P < .0001). The 2D variables also significantly differ between groups. The 3D perfusion density had the highest area under the receiver operating characteristic curve (0.964) among tested variables. Assessing quantitative perfusion using 3D analysis is reliable and promising, and with an elevated diagnostic efficacy in identifying DR eyes. 相似文献