首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
A simple, sensitive and reliable method was developed to determine simultaneously the concentrations of thienorphine and its metabolite thienorphine glucuronide conjugate in rat plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The metabolite was identified by MS: thienorphine glucuronide conjugate. Sample preparation involved protein precipitation with methanol. Analytes were separated on Finnigan BetaBasic-18 column (150 mm x 2.1mm i.d., 5 microm) using methanol: water: formic acid (56:44:0.1, v/v/v) as mobile phase at a flow rate of 0.2 ml/min. The method had a linear calibration curve over the concentration range of 0.1-50 ng/ml for thienorphine and 2-1000 ng/ml for thienorphine glucuronide conjugate, respectively. LOQ of thienorphine and thienorphine glucuronide conjugate was 0.1 and 2 ng/ml, respectively. The intra- and inter-batch precisions were less than 12% and their recoveries were greater than 80%. Pharmacokinetic data of thienorphine and its metabolite thienorphine glucuronide conjugate obtained with this method following a single oral dose of 3mg/kg thienorphine to rats were also reported for the first time.  相似文献   

3.
A simple reversed-phase liquid chromatographic method has been developed to determine protease inhibitors concentrations in plasma. Plasma samples (250 micro l) containing protease inhibitors were prepared by a simple deproteinization (recovery: 92, 91, 91 and 90.5% for ritonavir, saquinavir, nelfinavir and M8 nelfinavir metabolite, respectively). Chromatography was accomplished using a Hypersil octadecylsilyl column (100 x 4.6 mm I.D.) and a mobile phase composed of acetonitrile, tetrahydrofuran and dihydrogenophosphate buffer (pH 4) (32:10:58, v/v). Ultraviolet detection at 210 nm was used. The limit of detection was 200 ng/ml for ritonavir, saquinavir, nelfinavir and M8 nelfinavir metabolite. Calibration curves were linear up to 20000 ng/ml, with correlation coefficients better than 0.997 for all compounds. Intra- and inter-day coefficients of variation of the assay were 相似文献   

4.
A sensitive and selective high-performance liquid chromatographic method was developed for the determination of itraconazole and its active metabolite, hydroxyitraconazole, in human plasma. Prior to analysis, both compounds together with the internal standard were extracted from alkalinized plasma samples using a 3:2 (v/v) mixture of 2,2,4-trimethylpentane and dichloromethane. The mobile phase comprised 0.02 M potassium dihydrogen phosphate-acetonitrile (1:1, v/v) adjusted to pH 3.0. Analysis was run at flow-rate of 0.9 ml/min with excitation and emission wavelengths set at 260 and 365 nm, respectively. Itraconazole was found to adsorb on glass or plastic tubes, but could be circumvented by prior treating the tubes using 10% dichlorodimethylsilane in toluene. Moreover, rinsing the injector port with acetonitrile helped to overcome any carry-over effect. This problem was not encountered with hydroxyitraconazole. The method was sensitive with limit of quantification of 3 ng/ml for itraconazole and 6 ng/ml for hydroxyitraconazole. The calibration curve was linear over a concentration range of 2.8-720 ng/ml for itraconazole and 5.6-720 ng/ml for the hydroxy metabolite. Mean recovery value of the extraction procedure for both compounds was about 85%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 15%. Hence, the method is suitable for use in pharmacokinetic and bioavailability studies of itraconazole.  相似文献   

5.
We have developed a sensitive, selective and reproducible reversed-phase high-performance liquid chromatography method coupled with electrospray ionization mass spectrometry (HPLC-ESI-MS) for the simultaneous quantification of midazolam (MDZ) and its major metabolite, 1'-hydroxymidazolam (1'-OHM) in a small volume (200 microl) of human plasma. Midazolam, 1'-OHM and 1'-chlordiazepoxide (internal standard) were extracted from alkalinised (pH 9.5) spiked and clinical plasma samples using a single step liquid-liquid extraction with 1-chlorobutane. The chromatographic separation was performed on a reversed-phase HyPURITY Elite C18 (5 microm particle size; 100 mm x 2.1mm i.d.) analytical column using an acidic (pH 2.8) mobile phase (water-acetonitrile; 75:25% (v/v) containing formic acid (0.1%, v/v)) delivered at a flow-rate of 200 microl/min. The mass spectrometer was operated in the positive ion mode at the protonated-molecular ions [M+l]+ of parent drug and metabolite. Calibration curves in spiked plasma were linear (r2 > or = 0.99) from 15 to 600 ng/ml (MDZ) and 5-200 ng/ml (1'-OHM). The limits of detection and quantification were 2 and 5 ng/ml, respectively, for both MDZ and 1'-OHM. The mean relative recoveries at 40 and 600 ng/ml (MDZ) were 79.4+/-3.1% (n = 6) and 84.2+/-4.7% (n = 8), respectively; for 1'-OHM at 30 and 200 ng/ml the values were 89.9+/-7.2% (n = 6) and 86.9+/-5.6% (n = 8), respectively. The intra-assay and inter-assay coefficients of variation (CVs) for MDZ were less than 8%, and for 1'-OHM were less than 13%. There was no interference from other commonly used antimalarials, antipyretic drugs and antibiotics. The method was successfully applied to a pharmacokinetic study of MDZ and 1'-OHM in children with severe malaria and convulsions following administration of MDZ either intravenously (i.v.) or intramuscularly (i.m.).  相似文献   

6.
A simple and sensitive column-switching high-performance liquid chromatographic (HPLC) method with fluorescence detection is described for the quantification of perospirone, a serotonin and dopamine antagonist, and its metabolite ID-15036 in human plasma. The test compounds were extracted from 2 ml of plasma using chloroform-hexane (30:70, v/v) and the extract was injected into a column I (TSK-PW precolumn, 10 micro m, 35 x 4.6 mm I.D.) for clean-up and column II (C(18) STR ODS-II analytical column, 5 micro m, 150 x 4.6 mm I.D.) for separation. The peak was detected using a fluorescence detector set at Ex 315 nm and Em 405 nm, and the total time for a chromatographic separation was approximately 30 min. The method was validated for the concentration range from 0.1 to 100 ng/ml. Mean recoveries were 97% for perospirone and 96% for ID-15036. Intra- and inter-day relative standard deviations were less than 2.8 and 5.3% for perospirone and 2.4 and 4.4% for ID-15036, respectively, at the concentration range from 0.3 to 30 ng/ml. This method shows good specificity with respect to commonly prescribed psychotropic drugs, and it could be successfully applied for pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

7.
An analytical method for the determination of artemether (A) and its metabolite dihydroartemisinin (DHA) in human plasma has been developed and validated. The method is based on high-performance liquid chromatography (HPLC) and electrochemical detection in the reductive mode. A, DHA and artemisinin, the internal standard (I.S.), were extracted from plasma (1 ml) with 1-chlorobutane—isooctane (55:45, v/v). The solvent was transferred, evaporated to dryness under nitrogen and the residue dissolved in 600 μl of water-ethyl alcohol (50:50, v/v). Chromatography was performed on a Nova-Pak CN, 4 μm analytical column (150 mm×3.9 mm I.D.) at 35°C. The mobile phase consisted of pH 5 acetate—acetonitrile (85:15, v/v) at a flow-rate of 1 ml/min. The analytes were detected by electrochemical detection in the reductive mode at a potential of −1.0 V Intra-day accuracy and precision were assessed from the relative recoveries (found concentration in % of the nominal value) of spiked samples analysed on the same day (concentration range 10.9 to 202 ng/ml of A and 11.2 to 206 ng/ml of DHA in plasma). The mean recoveries over the entire concentration range were from 96 to 100% for A with C .V. from 6 to 13%, from 92% to 100% for DHA (α-tautomer) with C .V. from 4 to 16%. For A, the mean recovery was 96% at the limit of quantitation (LOQ) of 10.9 ng/ml with a CV of 13%. For DHA, the mean recovery was 100% at the LOQ of 11.2 ng/ml with a CV of 16%.  相似文献   

8.
A sensitive and specific high-performance liquid chromatographic assay with electrospray ionization mass spectrometry detection (LC-ESI-MS) has been developed and validated for the identification and quantification of the novel anticholinergic drug phencynonate in rat blood and urine. The sample pretreatment involves basification and iterative liquid-liquid extraction with ethyl ether-dichloromethane (2:1, v/v) solution, followed by LC separation and positive electrospray ionization mass spectrometry detection. The chromatography was on BetaBasic-18 column (150 mm x 2.1mm i.d., 3 microm). The mobile phase was composed of methanol-water (85:15, v/v), containing 0.5 per thousand formic acid, which was pumped at a flow-rate of 0.2 ml/min. Thiencynonate was selected as the internal standard (IS). Simultaneous MS detection of phencynonate and IS was performed at m/z 358.4 (phencynonate), m/z 364 (thiencynonate), and the selected reaction ion monitoring (SRM) of the two compounds was at 156. Phencynonate eluted at approximately 5.25 min, thiencynonate eluted at approximately 5.10 min and no endogenous materials interfered with their measurement. Linearity was obtained over the concentration range of 1-100 ng/ml in rat blood and 1-500 ng/ml in rat urine. The lower limit of quantification (LLOQ) was reproducible at 1 ng/ml in both of rat blood and urine. The precision measured was obtained from 2.92 to 9.76% in rat blood and 4.17 to 9.76% in rat urine. Extraction recoveries were in the range of 69.57-79.49% in blood and 56.85-64.86% in urine. This method was successfully applied to the identification and quantification of phencynonate in pharmacokinetic studies.  相似文献   

9.
A reverse-phase high performance liquid chromatography method with electrospray ionization and detection by mass spectrometry is described for the simultaneous determination of doxifluridine and its active metabolite 5-fluorouracil in monkey serum. A liquid/liquid extraction with ethyl acetate (90%) and isopropyl alcohol (10%) was used to extract simultaneously doxifluridine and 5-FU which have considerable difference in the polarity. Optimum chromatographic separation was achieved on a Agilent Zorbax C(18) (100 mm x 2.1mm, 3.5 microm) column with a mobile phase of methanol-water (20:80, v/v). The flow rate was 0.2 mL/min with total cycle time of 5 min. The lower limit of quantification (LLOQ) was validated at 10.0 ng/mL of serum for both doxifluridine and 5-FU. Accuracy and precision of quality control (QC) samples for both compounds met FDA Guidance criteria of +/-15% with average QC accuracy of 95.5-105.0% and coefficients of variation of 1.1-9.5% in the 10-2000 ng/mL concentration range. This method demonstrated adequate sensitivity, specificity, accuracy, precision, stability to support the analysis of monkey serum samples.  相似文献   

10.
A simple and sensitive HPLC method was developed to simultaneously determine CPT-11 and its major metabolite SN-38 in culture media and cell lysates. Camptothecin (CPT) was used as internal standard (I.S.). Compounds were eluted with acetonitrile-50 mM disodium hydrogen phosphate buffer containing 10 mM sodium 1-heptane-sulfonate, with the pH adjusted to 3.0 using 85% (w/v) orthophosphoric acid (27/73, v/v) by a Hyperclon ODS (C18) column (200 mm x 4.6 mm i.d.), with detection at excitation and emission wavelengths of 380 and 540 nm, respectively. The average extraction efficiencies were 96.9-108.3% for CPT-11 in culture media and 94.3-107.2% for CPT-11 in cell lysates; and 87.7-106.8% for SN-38 in culture media and 90.1-105.6% for SN-38 in cell lysates. Within- and between-day precision and accuracy varied from 0.1 to 10.3%. The limit of quantitation (precision and accuracy <20%) was 5.0 and 2.0 ng/ml for CPT-11 and 1.0 and 0.5 ng/ml for SN-38 in culture media and cell lysates, respectively. This method was successfully applied to quantitate the cellular accumulation and metabolism of CPT-11 and SN-38 in H4-II-E, a rat hepatoma cell line.  相似文献   

11.
An LC-MS/MS assay for the quantitative determination of a new antibacterial agent (AVE6971) has been developed and validated in human white blood cells (WBC). The assay involved a lysing procedure of white blood cells and ultra centrifugation of the extracts. Chromatography was performed on a Supelcosil ABZ+ C(18) (2.1 mm x 50 mm, 5 microm) column using a mobile phase consisting of methanol/acetonitrile/10mM ammonium formate mixture (10:30:60, v/v/v) at a flow rate of 0.2 ml/min. The linearity was within the range of 10-10000 ng/ml of extracts, corresponding to 0.5-500 ng of AVE6971 in WBC pellets tubes. The validated lower limit of quantification was 10 ng/ml. The inter- and intra-run coefficients of variation (CV) for the assay were <12.9% and the accuracy were from -9.0 to -1.2%. AVE6971 was stable in WBC for at least 1 month at -75 degrees C. This assay proved to be suitable for the determination of AVE6971 in WBC from clinical studies.  相似文献   

12.
Tramadol, an analgesic agent, and its two main metabolites O-desmethyltramadol (M1) and N-desmethyltramadol (M2) were determined simultaneously in human plasma by a rapid and specific HPLC method. The sample preparation was a simple extraction with ethyl acetate. Chromatographic separation was achieved with a Chromolith Performance RP-18e 50 mm x 4.6 mm column, using a mixture of methanol:water (13:87, v/v) adjusted to pH 2.5 by phosphoric acid, in an isocratic mode at flow rate of 2 ml/min. Fluorescence detection (lambda(ex)=200 nm/lambda(em)=301 nm) was used. The calibration curves were linear (r(2)>0.997) in the concentration range of 2.5-500 ng/ml, 1.25-500 ng/ml and 5-500 ng/ml for tramadol, M1 and M2, respectively. The lower limit of quantification was 2.5 ng/ml for tramadol, 1.25 ng/ml for M1 and 5 ng/ml for M2. The within- and between-day precisions in the measurement of QC samples at four tested concentrations were in the range of 2.5-9.7%, 2.5-9.9% and 5.9-11.3% for tramadol, M1 and M2, respectively. The developed procedure was applied to assess the pharmacokinetics of tramadol and its two main metabolites following administration of 100mg single oral dose of tramadol to healthy volunteers.  相似文献   

13.
We have developed a sensitive, selective and reproducible reversed-phase HPLC method with ultraviolet detection (340 nm) for the simultaneous quantification of amodiaquine (AQ) and its major metabolite, desethylamodiaquine (AQm) in a small volume (200 microl) of whole blood spotted on filter paper. The method involves liquid-liquid extraction with diethyl ether followed by elution from a reversed-phase phenyl column with an acidic (pH 2.8) mobile phase (25 mM KH2PO4-methanol; 80:20% (v/v) +1% (v/v) triethylamine). Calibration curves in spiked whole blood were linear from 100-2500 ng/ml (r2 > or = 0.99) for AQ and 200-2500 ng/ml (r2 > or = 0.99) for AQm. The limit of detection was 5 ng for AQ and 10 ng for AQm. The relative recovery at 150 ng/ml of AQ (n = 6) was 84.0% and at 300 ng/ml of AQm the relative recovery was 74.3%. The intra-assay coefficients of variation at 150, 600 and 2250 ng/ml of AQ and 300, 600 and 2250 ng/ml of AQm were 7.7, 8.9 and 6.2% (AQ) and 10.1, 5.4 and 3.9% (AQm), respectively. The inter-assay coefficient of variation at 150, 600 and 2250 ng/ml of AQ and 300, 600 and 2250 ng/ml of AQm were 5.2, 8.1 and 6.9% (AQ) and 3.3, 2.3 and 4.6% (AQm). There was no interference from other commonly used antimalarial and antipyretic drugs (chloroquine, quinine, sulfadoxine, pyrimethamine, artesunate, acetaminophen and salicylate). The method is particularly suitable for pharmacokinetic studies in settings where facilities for storing blood/plasma samples are not available.  相似文献   

14.
A reversed-phase high-performance liquid chromatographic (HPLC) method with ultraviolet (UV) detection was developed and validated for the quantification of 6-deoxy-6-demethyl-4-dedimethylamino-tetracycline (COL-3), a matrix metalloproteinase (MMPs) inhibitor, in rat serum. This simple, sensitive, rapid and reproducible assay involved a preliminary serum deproteinization by adding a mixture of acetonitrile-methanol-0.5 M oxalic acid (70:20:10 (v/v)), as the combined precipitant and metal blocking agent, into serum samples (2:1 (v/v)). An aliquot (20 microl) of the supernatant was injected into the HPLC system linked to a Waters XTerra RP(18) column (150 mm x 4.6 mm i.d., particle size 5 microm). The compound was eluted by a mixture of acetonitrile-methanol-0.01 M oxalic acid (40:10:50 (v/v), pH 2.00), as the mobile phase, and detected at the wavelength of 350 nm. The total running time was 10 min. The low and high concentration calibration curves were linear in the range of 50-1200 ng/ml and 1200-12,000 ng/ml, respectively. The intra- and inter-day coefficients of variation at three quality control concentrations of 100, 1200, and 12,000 ng/ml were all less than 6%, while the percent error ranged from -2.5 to 6.6%. The limit of quantitation (LOQ) for COL-3 in serum was 50 ng/ml. This assay was successfully employed to study the serum concentration-time profiles of COL-3 after its intravenous and oral administration in rats. The method with some minor modifications in sample pretreatment was also applicable to the determination of the concentrations of COL-3 in rat bile, urine and feces.  相似文献   

15.
A high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI/MS) method for simultaneous stereoselective analysis of venlafaxine (VEN) and its major metabolite O-desmethylvenlafaxine (ODV) enantiomers in human plasma has been developed and validated. Chiral chromatography is performed on the CHRIOBIOTIC V (5 microm, 250 mm x 4.6 mm) column with mobile phase constituted of 30 mmol/l ammonium acetate-methanol (15:85, pH 6.0) at a flow rate of 1.0 ml/min and a postcolumn splitting ratio of 3:1. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer and detected using the selected ion recording (SIR) mode. Calibration curves obtained from spiked plasma were linear in the range of 5.0-400 ng/ml for S-(+)-VEN and R-(-)-VEN, 4.0-280 ng/ml for S-(+)-ODV and R-(-)-ODV, respectively, with linear correlation coefficient all above 0.999. The average extraction recoveries for all the four analytes were above 76%. The methodology recoveries were higher than 92%. The limit of detection were 1.0 ng/ml for S-(+)-VEN and R-(-)-VEN, 1.5 ng/ml for S-(+)-ODV and R-(-)-ODV, respectively. The intra- and inter-day variation coefficients were less than 9%.  相似文献   

16.
A high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous analysis of the local anesthetic amide drugs, bupivacaine, mepivacaine and ropivacaine, belonging to the pipecoloxylidide group using a C(18) reversed-phase column (150 x 4.6 mm I.D.) filled with 5-microm particles and attached to a UV detector. The mobile phase was composed of acetonitrile-methanol-30 mM NaH(2)PO(4) (pH 5.6) (100:100:300, v/v/v) and the flow rate was 1ml/min. The absorbance of the eluate was monitored at 210 nm. The retention times of the three compounds were: 4.6 min (mepivacaine), 9.7min (ropivacaine) and 16.4 min (bupivacaine). With this sample preparation method, good and consistent recoveries of the three compounds were obtained: 88-91% for mepivacaine, 87-89% for ropivacaine and 88-91% for bupivacaine. The limit of quantification for three compounds in human serum was 2 ng/ml for mepivacaine, 5 ng/ml for bupivacaine and ropivacaine. This method may be useful in clinical and forensic applications for the determination or identification of the local anesthetic drugs: bupivacaine, mepivacaine or ropivacaine.  相似文献   

17.
A simple and sensitive high-performance liquid chromatographic (HPLC) method with UV absorbance detection is described for the quantitation of risperidone and its major metabolite 9-hydroxyrisperidone in human plasma, using clozapine as internal standard. After sample alkalinization with 1 ml of NaOH (2 M) the test compounds were extracted from plasma using diisopropyl ether–isoamylalcohol (99:1, v/v). The organic phase was back-extracted with 150 μl potassium phosphate (0.1 M, pH 2.2) and 60 μl of the acid solution was injected into a C18 BDS Hypersil analytical column (3 μm, 100×4.6 mm I.D.). The mobile phase consisted of phosphate buffer (0.05 M, pH 3.7 with 25% H3PO4)–acetonitrile (70:30, v/v), and was delivered at a flow-rate of 1.0 ml/min. The peaks were detected using a UV detector set at 278 nm and the total time for a chromatographic separation was about 4 min. The method was validated for the concentration range 5–100 ng/ml. Mean recoveries were 98.0% for risperidone and 83.5% for 9-hydroxyrisperidone. Intra- and inter-day relative standard deviations were less than 11% for both compounds, while accuracy, expressed as percent error, ranged from 1.6 to 25%. The limit of quantitation was 2 ng/ml for both analytes. The method shows good specificity with respect to commonly prescribed psychotropic drugs, and it has successfully been applied for pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

18.
We developed a simple and sensitive method for the simultaneous detection of imatinib mesylate (IM) and its active metabolite, N-desmethyl imatinib (M1), in human serum samples. Separation was successfully achieved using an Agilent(?) ZORBAX Eclipse plus C(18) reversed phase column (50 mm × 2.1 mm, i.d.; 1.8 μm) under isocratic mobile phase conditions consisting of acetonitrile: 0.02 M potassium dihydrogen phosphate with 0.2% triethylamine at pH 3 (25:75, v/v) and ultra-violet detection was achieved at 235 nm. Extraction of the target compounds was completed using 100% cold acetonitrile. Good linearities (r(2)>0.99) for both IM and M1 were achieved for the concentration ranges of 50-1800 ng/mL and 50-360 ng/mL, respectively. The detection limits were 20 ng/mL and 10 ng/mL for M1 and IM, respectively. The intra- and inter-day precisions were less than 1% with percent recoveries of more than 90%. The method was successfully applied to calculate the pharmacokinetic parameters of chronic myeloid leukemia patients receiving imatinib. The method is suitable to be routinely applied for determination of IM and M1 in serum.  相似文献   

19.
A simple and sensitive high-performance liquid chromatography (HPLC) assay for the analysis of CZ48, a potent anticancer candidate, and its active metabolite camptothecin (CPT) in mouse plasma was developed and validated. CZ44 was used as an internal standard (IS). The samples were injected onto a C18 Synergi Polar-RP column (4 microm, 150 mm x 4.60 mm) maintained at 30 degrees C. The identification of peaks showed high specificity. Shimadzu RF-10AXL fluorescence detector was used at the excitation and emission of 380 and 418 nm, respectively. The mean recoveries were 81.41+/-0.035%, 86.00+/-0.053% and 82.21+/-0.020% for CZ48 and 76.01+/-0.028%, 77.04+/-0.042% and 85.93+/-0.023% for CPT at three concentrations of 10, 100 and 900 ng/ml, respectively. The calibration curve was linear (r(2)=0.9999) over CZ48 and CPT concentrations ranging from 5 to 1000 ng/ml and 10-1000 ng/ml (n=6), respectively. The method had an accuracy of >95% and intra- and inter-day precision (RE%) of <1.2% and <2.2% for CZ48 and CPT, respectively, at three different concentrations (10, 100 and 900 ng/ml). The lower limit of quantification (LLOQ) using 0.1 ml mouse plasma was 10 ng/ml for CZ48 and 5 ng/ml for CPT. Stability studies showed that CZ48 and CPT were stable in mouse plasma after 4h incubation at room temperature or after 1 month storage at -80 degrees C with three freeze/thaw cycles. The method reported is simple, reliable, precise and accurate and confirmed by the determination of plasma samples in the mice after oral administration of CZ48.  相似文献   

20.
A sensitive and specific LC/MS/MS method has been developed and validated for determination of ragaglitazar (NNC 61-0029 or DRF 2725) in human plasma. After solid-phase extraction (SPEC((R)) PLUS C(8)) of plasma, separation was performed on a Symmetry Shield RP8 column (mobile phase: acetonitrile: 10 mM ammonium acetate, pH 5.6 (40:60 v/v)). Two ranges were validated having LLOQs of either 0.500 or 100 ng/ml and linearity up to either 500 or 50000 ng/ml. The intra-assay precision and accuracy were 1.1% to 15.7% and 85.8% to 118.2% (range 0.500-500 ng/ml) and 2.0% to 8.8% and 92.9% to 104.8% (range 100-50000 ng/ml). The method was applied for determination of ragaglitazar in plasma from phase 1 and 2 clinical studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号