首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive method was developed and validated for the measurement of 17-(allylamino)-17-demethoxygeldanamycin (17AAG) and its active metabolite 17-amino-17-demethoxygeldanamycin (17AG) in human plasma using 17-(dimethylaminoethylamino)-17-demethoxygeldanamycin (17DMAG) as an internal standard. After the addition of internal standard, 200 microL of plasma was extracted using ice cold acetonitrile followed by analysis on a Thermo Finnigan triple-quadruple mass spectrometer coupled to an Agilent 1100 HPLC system. Chromatography was carried out on a 50 mm x 2.1 mm Agilent Zorbax SB-phenyl 5 microm column coupled to a 3mm Varian metaguard diphenyl pre-column using glacial acetic acid 0.1% and a gradient of acetonitrile and water at a flow rate of 500 microL/min. Atmospheric pressure chemical ionization and detection of 17AAG, 17AG and 17DMAG were accomplished using selected reaction monitoring of m/z 584.3>541.3, 544.2>501.2, and 615.3>572.3, respectively in negative ion mode. Retention times for 17AAG, 17AG, and 17DMAG were 4.1, 3.5, and 2.9 min, respectively, with a total run time of 7 min. The assay was linear over the range 0.5-3000 ng/mL for 17AAG and 17AG. Replicate sample analysis indicated within- and between-run accuracy and precision within 15%. The recovery of 17AAG and 17AG from 200 microL of plasma containing 1, 25, 300, and 2500 ng/mL was 93% or greater. This high-performance liquid chromatographic tandem mass spectroscopy (HPLC/MS/MS) method is superior to previous methods. It is the first analytical method reported to date for the quantitation of both 17AAG and its metabolite 17AG and can reliably quantitate concentrations of both compounds as low as 0.5 ng/mL.  相似文献   

2.
Selective and sensitive methods for the determination of the cationic dye and anti-malarial methylene blue in human liquid whole blood, dried whole blood (paper spot), and plasma depending on protein precipitation and cation exchange chromatography coupled to electrospray ionisation (ESI) tandem mass spectrometry (MS/MS) have been developed, validated according to FDA standards, and applied to samples of healthy individuals and malaria patients within clinical studies. Acidic protein precipitation with acetonitrile and trifluoroacetic acid was used for liquid whole blood and plasma. For the extraction of methylene blue from paper spots aqueous acetonitrile was used. Sample extracts were chromatographed on a mixed mode column (cation exchange/reversed phase, Uptisphere MM1) using an aqueous ammonium acetate/acetonitrile gradient. Methylene blue was quantified with MS/MS in the selected reaction monitoring mode using ESI and methylene violet 3RAX as internal standard. Depending on the sample volume (whole blood and plasma 250 microL, and 100 microL on paper spots) the method was linear at least within 75 and 10,000 ng/mL and the limit of quantification in all matrices was 75 ng/mL. Batch-to-batch accuracies of the whole blood, plasma, and paper spot methods varied between -4.5 and +6.6%, -3.7 and +7.5%, and -5.8 and +11.1%, respectively, with corresponding precision ranging from 3.8 to 11.8% CV. After a single oral dose (500 mg) methylene blue concentrations were detectable for 72 h in plasma. The methods were applied within clinical studies to samples from healthy individuals and malaria patients from Burkina Faso.  相似文献   

3.
Simultaneous separation and quantification of ezetimibe (EZM) and its phase-I metabolite i.e., ezetimibe ketone (EZM-K) and phase-II metabolite i.e., ezetimibe glucuronide (EZM-G) in various matrices was accomplished by gradient HPLC with UV detection. The assay procedure involved deproteinization of 500 microL of either incubation or bile sample containing analytes and internal standard (IS, theophylline) with 75 microL acetonitrile containing 25% perchloric acid. An aliquot of 100 microL supernatant was injected onto a C18 column. The chromatographic separation was achieved by gradient elution consisting of 0.05 M formic acid:acetonitrile:methanol:water at a flow rate of 1.0 mL/min. The detection of analyte peaks were achieved by monitoring the eluate using an UV detector set at 250 nm. Nominal retention times of IS, EZM-G, ezetimibe ketone glucuronide (EZM-KG), EZM and EZM-K were 9.39, 24.23, 27.82, 29.04 and 30.56 min, respectively. Average extraction efficiencies of EZM, EZM-G and IS was >75-80% and for EZM-K was >50% from all the matrices tested. Limit of quantitation (LOQ) for EZM, EZM-K and EZM-G was 0.02 microg/mL. Due to the lack of availability of reference standard of EZM-KG, the recovery and LOQ aspects for this metabolite were not assessed. Overall, the method is suitable for simultaneous measurement of EZM, and its phase-I and phase-II metabolite (EZM-G) in in vitro and in vivo studies.  相似文献   

4.
A sensitive and specific high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) method has been developed and validated for the determination of palmatine in canine plasma. Palmatine and jatrorrhizine (internal standard, I.S.) were extracted from plasma samples by solid-phase extraction (SPE) using Oasis HLB cartridges. The chromatographic separation was performed on a Waters XTerra MS C(18) reversed-phase column at 30 degrees C. The gradient mobile phase, delivered at 0.25 mL/min, was composed of a mixture of acetonitrile -0.1% (v/v) acetic acid aqueous solution adjusted to pH 2.8 with triethylamine. Positive electrospray ionization was utilized as the ionization source. Palmatine and the internal standard (I.S.) were determined using multiple reaction monitoring (MRM) of precursor-->product ion transitions at m/z 352-->336 and m/z 338-->322, respectively. The lower limit of quantification (LLOQ) was 0.1 ng/mL using 100 microL plasma samples and the linear calibration range was from 0.1 to 500 ng/mL. The inter-day and intra-day RSDs were lower than 9.9% and the recoveries of palmatine ranged from 87.3 to 100.9%. The mean extraction recoveries of palmatine and the I.S. were 99.2 and 96.8%, respectively. The method has been successfully applied to the pharmacokinetic studies of palmatine in beagle dogs after oral administration and intramuscular injection of palmatine.  相似文献   

5.
A simple reversed phase high-performance liquid chromatographic method was established for the separation and quantification of a novel prodrug of zidovudine in rat plasma. Zidovudine was one of the original drugs used to treat HIV infection. Appropriate aliquots of rat plasma were spiked with cholesteryl carbonate zidovudine (AZTC) and treated with acetonitrile to precipitate plasma proteins. The supernatant after supercentrifugation was collected and an aliquot of 20 microL was injected directly into an HPLC system consisting of a Diamonsil C18 column and a diode array detector. The mobile phase consisted of methanol (85%, v/v) and diethyl ether (15%, v/v) at a flow rate of 1.0 mL/min. The extraction recoveries of AZTC at the three concentrations examined were all higher than 80%. The HPLC assay was linear over the concentration range 0.5-80 microg/mL. A one-compartment model with apparent first-order elimination was used to describe the plasma concentration-time profile for AZTC after administration via the tail vein. The mean elimination half-life (t1/2) was 292.4 min. This RP-HPLC method will be useful for the evaluation of the pharmacokinetics of AZTC in rats.  相似文献   

6.
A simple, sensitive and rapid liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated to quantify griseofulvin in human plasma using propranolol hydrochloride as internal standard (IS). Samples were prepared using solid phase extraction and analysed without drying and reconstitution. The analytes were chromatographed on Hypersil, hypurity C18 reverse phase column under isocratic conditions using 0.05% formic acid in water:acetonitrile (30:70, v/v) as the mobile phase. Total chromatographic run time was 3.0 min. Quantitation was done on a triple quadrupole mass analyzer API-3000, equipped with turbo ion spray interface and operating in multiple reaction monitoring (MRM) mode to detect parent-->product ion transition for analyte and IS. The method was validated for sensitivity, matrix effect, accuracy and precision, linearity, recovery and stability studies. Linearity in plasma was observed over the concentration range 20-3000 ng/mL for griseofulvin. Lower limit of quantification (LLOQ) achieved was 20 ng/mL with precision (CV) less than 10% using 5 microL injection volume. The absolute recovery of analyte (87.36%) and IS (98.91%) from spiked plasma samples was consistent and reproducible. Inter-batch and intra-batch coefficients of variation across four validation runs (LLOQ, LQC, MQC and HQC) was less than 7.5%. The accuracy determined at these levels was within +/-4.2% in terms of relative error. The method was applied to a pilot bioequivalence study of 500 mg griseofulvin tablet in six healthy human subjects under fed condition.  相似文献   

7.
8.
A sensitive, specific and rapid liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed and validated for quantification of nalmefene in human plasma. An aliquot of 200 microL plasma sample was simply precipitated by 400 microL methanol. Separation of nalmefene and the internal standard hydromorphone from the interferences was achieved on a C(18) column followed by MS/MS detection. The analytes were monitored in the positive ionization mode with a TurboIonspray source. The method had a total chromatographic run time of 4.5 min and linear calibration curves over the concentration range of 10-5000 pg/mL. The lower limit of quantification (LLOQ) was 10 pg/mL. The intra- and inter-day precision was less than 10.1% determined from QC samples at concentrations of 30, 300 and 4500 pg/mL, and the accuracy was within +/-3.4%. As the method was more sensitive (10 times higher) than those reported previously, we investigated the pharmacokinetics of nalmefene in healthy volunteers after a single intravenous injection of low dose (30 microg) of nalmefene hydrochloride for the first time.  相似文献   

9.
A simple, reliable and sensitive liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for quantification of N-acetylglucosamine in human plasma. Plasma samples were pretreated with acetonitrile for protein precipitation. The chromatographic separation was performed on Hypersil Silica column (150mmx2mm, 5microm). The deprotonated analyte ion was detected in negative ionization mode by multiple reaction monitoring mode. The mass transition pairs of m/z 220.3-->118.9 and m/z 226.4-->123.2 were used to detect N-acetylglucosamine and internal standard 13C6-N-acetylglucosamine, respectively. The assay exhibited a linear range from 20 to 1280ng/ml for N-acetylglucosamine in human plasma. Acceptable precision and accuracy were obtained for concentrations of the calibration standard and quality control. The validated method was successfully applied to analyze human plasma samples in a pharmacokinetic study.  相似文献   

10.
A sensitive and selective high-performance liquid chromatographic (HPLC) method with ultra-violet detection has been developed and validated for the simultaneous determination of posaconazole and voriconazole, two systemic anti-fungal agents. An internal standard diazepam was added to 100 microL of human plasma followed by 3 mL of hexane-methylene chloride (70:30, v/v). The organic layer was evaporated to dryness and the residue was reconstituted with 100 microL of mobile phase before being injected in the chromatographic system. The compounds were separated on a C8 column using sodium potassium phosphate buffer (0.04 M, pH 6.0): acetonitrile:ultrapure water (45:52.5:2.5, v/v/v) as mobile phase. All compounds were detected at a wavelength of 255 nm. The assay was linear and validated over the range 0.2-10.0 mg/L for voriconazole and 0.05-10.0 mg/L for posaconazole. The biases were comprised between -3 and 5% for voriconazole and -2 and 8% for posaconazole. The intra- and inter-day precisions of the method were lower than 8% for the routine quality control (QC). The mean recovery was 98% for voriconazole and 108% for posaconazole. This method provides a useful tool for therapeutic drug monitoring.  相似文献   

11.
A sensitive liquid chromatography-mass spectrometric (LC/MS) method for the quantification of ginsenoside Rd in dog plasma was developed and validated after solid-phase extraction (SPE).Chromatographic separation was achieved on a reversed-phase Cromosil C(18) column with the mobile phase of acetonitrile-ammonium chloride (500 micromol/L) and step gradient elution resulted in a total run time of about 5.5 min. The analytes were detected by using an electrospray negative ionization mass spectrometry in the selected ion monitoring (SIM) mode. A good linear relationship was obtained in the concentration range studied (0.005-2.500 microg/mL) (r=0.9998). Lower limit of quantification (LLOQ) was 5 ng/mL by using 500 microL plasma sample. Average recoveries ranged from 70.71 to 75.89% in plasma at the concentrations of 0.010, 0.100 and 2.500 microg/mL. Intra- and inter-day relative standard deviations were 8.49-11.71 and 5.71-16.48%, respectively. This method was successfully applied to the pharmacokinetic studies on dogs. The absolute bioavailability of Rd in dogs was 0.26%.  相似文献   

12.
A rapid and selective liquid chromatographic/tandem mass spectrometric method for determination of fosfomycin was developed and validated. Following protein-precipitation, the analyte and internal standard (fudosteine) were separated from human plasma using an isocratic mobile phase on an Ultimate XB-CN column. An API 4000 tandem mass spectrometer equipped with Turbo IonSpray ionization source was used as detector and was operated in the negative ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 137-->79 and m/z 178-->91 was performed to quantify fosfomycin and fudosteine, respectively. The method was linear in the concentration range of 0.10-12.0 microg/mL using 50 microL of plasma. The lower limit of quantification was 0.10 microg/mL. The intra- and inter-day relative standard deviation over the entire concentration range was less than 10.6%. Accuracy determined at three concentrations (0.25, 1.00 and 8.00 microg/mL for fosfomycin) ranged from -1.0% to -4.2% in terms of relative error. Each plasma sample was chromatographed within 5.0 min. The method was successfully used in a bioequivalence study of fosfomycin in human plasma after an oral administration of capsules containing 1.0 g fosfomycin (approximately 1.3g calcium fosfomycin).  相似文献   

13.
A sensitive method for the determination of lapatinib (GW572016) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Plasma samples (100 microL) were prepared using solid phase extraction (SPE) columns, and 6.0 microL of the reconstituted eluate was injected onto a Phenomenex CuroSil-PFP 3 mu analytical column (50 mm x 2.0mm) with an isocratic mobile phase. Analytes were detected with a PE SCIEX API-365 LC-MS/MS system at unit (Q1) and low (Q3) resolution in positive multiple reaction monitoring mode (m/z 581 (precursor ion) to m/z 364 (product ion) for lapatinib). The mean recovery for lapatinib was 75% with a lower limit of quantification of 15 ng/mL (S/N=11.3, CV< or =14%). This method was validated over a linear range of 100-10,000 ng/mL, and results from a 5-day validation study demonstrated good within-day and between-day precision and accuracy. This method has been used to measure plasma lapatinib concentrations in a Phase I study in children with cancer.  相似文献   

14.
A sensitive and selective liquid chromatographic method coupled with mass spectrometry (LC-MS) was developed for the quantification of phloroglucinol in human plasma. Resorcinol was used as internal standard, with plasma samples extracted using ethyl acetate. A centrifuged upper layer was then evaporated and reconstituted with mobile phase. The reconstituted samples were injected into a C(18) XTerra MS column (2.1 x 100 mm) with 3.5-microm particle size. The analytical column lasted for at least 500 injections. The mobile phase was 15% acetonitrile (pH 3.0), with flow-rate at 200 microl/min. The mass spectrometer was operated in negative ion mode with selective ion monitoring (SIM). Phloroglucinol was detected without severe interferences from plasma matrix when used negative ion mode. Phloroglucinol produced a parent molecule ([M-H](-)) at m/z 125 in negative ion mode. Detection of phloroglucinol in human plasma was accurate and precise, with quantification limit at 5 ng/ml. This method has been successfully applied to a study of phloroglucinol in human specimens.  相似文献   

15.
A fully automated chromatographic method including on-line blood serum or plasma clean-up, isocratic high-performance liquid chromatography (HPLC) and spectrophotometric detection was developed for quantitative analysis of the new antipsychotic drug amisulpride. After injection of serum or plasma onto the HPLC system and clean-up on a pre-column (10x4.0 mm I.D.) filled with Silica CN 20 micrometer (pore size 10 nm) by an eluent consisting of 8% acetonitrile in deionized water, the chromatographic separation was performed on Lichrospher CN (5 micrometer; 250x4.6 mm I.D.) by an eluent consisting of 50% acetonitrile and 50% aqueous potassium phosphate buffer (0.008 M, pH 6.4). The UV detector was set at 254 nm. The limit of quantification was about 10 microgram/l. The method revealed linearity between 10 and 600 microgram/l (correlation coefficients R(2)>0.9996). The inter-assay reproducibility (coefficient of variation) of quality control samples was between 2.8 and 11.3%. Inaccuracy was between -0.6 and +9.1%. The performance of daily calibration standards revealed an imprecision always below 15% and maximum inaccuracy of 7.7%. The method can be applied to therapeutic drug monitoring as well as pharmacokinetic studies of amisulpride.  相似文献   

16.
A rapid and sensitive liquid chromatographic/tandem mass spectrometric method for determination of misoprostol acid, the active metabolite of misoprostol, was developed and validated. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a C(18) column. An API 4000 tandem mass spectrometer equipped with Turbo IonSpray ionization source was used as detector and was operated in the negative ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 367-249 and 296-269 was performed to quantify misoprostol acid and the internal standard hydrochlorothiazide, respectively. The method was linear in the concentration range of 10.0-3000 pg mL(-1) using 200 microL plasma. The lower limit of quantification was 10.0 pg mL(-1). The intra- and inter-day relative standard deviation over the entire concentration range was less than 8.3%. Accuracy determined at three concentrations (25.0, 200 and 2700 pg mL(-1) for misoprostol acid) ranged from -0.5 to 1.2% in terms of relative error. Each plasma sample was chromatographed within 3.5 min. The method was successfully used in a pharmacokinetic study of misoprostol in human plasma after an oral administration of 0.6 mg misoprostol.  相似文献   

17.
A rapid, sensitive and specific high performance liquid chromatography-electrospray ionization tandem quadrupole mass spectrometry (HPLC-MS/MS) method was developed and validated for the determination of 3-n-butylphthalide in rat plasma. Following protein precipitation with acetonitrile, 3-n-butylphthalide and glipizide (internal standard, I.S.) were separated using a gradient elution program on a C18 column and detected by mass spectrometry in positive ion mode with the multiple reaction monitoring (MRM) mode using the respective precursor to product ion combinations of m/z 191/145 for 3-n-butylphthalide and m/z 446/321 for glipizide, respectively. The total chromatographic running time was 2.5 min. The method was linear over the concentration range of 11.14-3480.00 ng/mL, using as little as 100 microL plasma. The lower limit of quantification (LLOQ) was 5.57 ng/mL. Finally, the method was successfully used to support a preclinical pharmacokinetic study of 3-n-butylphthalide in rats following intravenous administration.  相似文献   

18.
A simple method for the quantification of tipranavir, the first non-peptidic HIV protease inhibitor, was developed and validated. Quinoxaline, as internal standard, was added to 50 microl of plasma before a liquid-liquid extraction by 600 microl of protein precipitation solution. The extracts were diluted before being injected in the chromatographic system. Chromatographic separation was made on a C18 column using potassium phosphate buffer (pH 3.2) and acetonitrile with gradient. Detection was performed by an UV detector at 260 nm. Relative error at three control quality concentrations ranged from -1.81 to 1.72%. Intra-day (CV%) and inter-day (CV%) precision ranged from 0.94 to 2.55% and from 3.07 to 4.24%, respectively. LOQ and LOD were 0.090 microg/ml and 0.035 microg/ml, respectively. Mean recovery was 87.1%+/-2.4%. Calibration curve was linear up to 180 microg/ml. Concentration range when optimized (0.703-180 microg/ml) proved to be adequate to measure tipranavir concentration in HIV-1-positive patients, therefore this method could be suitable for therapeutic drug monitoring of this drug.  相似文献   

19.
There is increasing evidence that the clinical efficacy of tamoxifen, the first and most widely used targeted therapy for estrogen-sensitive breast cancer, depends on the formation of the active metabolites 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen (endoxifen). Large inter-individual variability in endoxifen plasma concentrations has been observed and related both to genetic and environmental (i.e. drug-induced) factors altering CYP450s metabolizing enzymes activity. In this context, we have developed an ultra performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) requiring 100 μL of plasma for the quantification of tamoxifen and three of its major metabolites in breast cancer patients. Plasma is purified by a combination of protein precipitation, evaporation at room temperature under nitrogen, and reconstitution in methanol/20 mM ammonium formate 1:1 (v/v), adjusted to pH 2.9 with formic acid. Reverse-phase chromatographic separation of tamoxifen, N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen is performed within 13 min using elution with a gradient of 10 mM ammonium formate and acetonitrile, both containing 0.1% formic acid. Analytes quantification, using matrix-matched calibration samples spiked with their respective deuterated internal standards, is performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection in the positive mode. The method was validated according to FDA recommendations, including assessment of relative matrix effects variability, as well as tamoxifen and metabolites short-term stability in plasma and whole blood. The method is precise (inter-day CV%: 2.5-7.8%), accurate (-1.4 to +5.8%) and sensitive (lower limits of quantification comprised between 0.4 and 2.0 ng/mL). Application of this method to patients' samples has made possible the identification of two further metabolites, 4'-hydroxy-tamoxifen and 4'-hydroxy-N-desmethyl-tamoxifen, described for the first time in breast cancer patients. This UPLC-MS/MS assay is currently applied for monitoring plasma levels of tamoxifen and its metabolites in breast cancer patients within the frame of a clinical trial aiming to assess the impact of dose increase on tamoxifen and endoxifen exposure.  相似文献   

20.
A precise and accurate high-performance liquid chromatography (HPLC) method with UV detection has been developed and validated for darunavir, a peptidic protease inhibitor. An internal standard, methylclonazepam, was added to 100 microL of plasma before a solid-phase extraction on C18 Bond Elut column. The eluted solutions were evaporated to dryness and reconstituted with 100 microL of mobile phase before being injected in the chromatographic system. The separation was performed on a C8 column using an acetonitrile and ultrapure water mixture (40:60, v/v) as mobile phase. All compounds were detected at a wavelength of 266 nm. The method was linear and validated over a concentration range of 0.25-20mg/L. The within-day precision, ranged from 3.0 to 7.9%, while the within-day accuracy ranged from -11.4 to 0.5%. The between day precision and accuracy were respectively less than 13.7 and -11.4%. The mean recovery was 75.7% for darunavir and 66.7% for methylclonazepam. This method provides a useful tool for therapeutic drug monitoring in HIV patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号