首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In patients with sick sinus syndrome and normal atrioventricular conduction, physiological pacing can be accomplished with either a single chamber atrial pacemaker AAI/R or a dual chamber pacemaker DDD/R. The single chamber device has the advantages of simpler implantation and lower initial costs, while the dual chamber device offers protection in case atrioventricular conduction disturbances develop in the future. When rigorous attention is paid to the pre-implantation selection criteria, the incidence of reported second- or third-degree atrioventricular block varied between 0.4 and 1.8% per annum. Medical practice, however, has shifted to predominant implantation of DDD/R pacemakers in more than 95% of patients with sick sinus syndrome. Recent publications have reported an increase in left atrial diameter, decrease in left ventricular fractional shortening and increased incidence of atrial fibrillation in patients with DDD/R pacing as compared with patients with single chamber atrial devices. These changes were proportional to the percentage of ventricular paced beats. New algorithms in dual chamber devices have been developed in order to minimise ventricular stimulation. These are being evaluated at present. In my opinion there is still a place for atrial pacing in selected patients with sick sinus syndrome with a minimum risk of developing complete atrioventricular block. (Neth Heart J 2008;16(suppl 1): S25-S27.)  相似文献   

2.
In selected patients with atrial fibrillation and severe symptoms, non-pharmacological treatment may be an alternative or supplement to drug therapy. Atrioventricular nodal radiofrequency ablation (requires pacemaker implantation), or atrial pacing for sick sinus syndrome, are established treatment modalities. All other non-pharmacological therapies for atrial fibrillation are still experimental. After the Maze operation, atrial depolarization has to follow one specific path determined by surgical scars in the myocardium. This prevents new episodes of atrial fibrillation, but at a cost of perioperative morbidity and mortality. Catheter-based "Maze-like" radiofrequency ablation is technically difficult, and thrombo-embolic complications may occur. Paroxysmal atrial fibrillation sometimes is initiated by spontaneous depolarizations in a pulmonary vein inlet. Radio frequency ablation against such focal activity has been reported with high therapeutic success, but the results await confirmation from several centres. For ventricular rate control, most electrophysiologists presently prefer ablation to induce a complete atrioventricular conduction block (with pacemaker) rather than trying to modify conduction by incomplete block. Atrial or dual chamber pacing may prevent atrial fibrillation induced by bradycardia. It remains to confirm that biatrial or multisite right atrial pacing prevents atrial fibrillation more efficiently than ordinary right atrial pacing. An atrial defibrillator is able to diagnose and convert atrial fibrillation. The equipment is expensive, and therapy without sedation may be unpleasant beyond tolerability.  相似文献   

3.
Re-use of DDD pulse generators explanted from patients died of unrelated causes is associated with an additional cost of two transvenous leads if implanted as DDD itself, and high rate of infection according to some studies. We studied the clinical and economical aspects of reutilization of explanted DDD pacemakers programmed to VDD mode. Out of 28 patients who received VDD pacemaker during the period, October 2000- September 2001 in the Department of Cardiology, PGIMER, Chandigarh, 5 poor patients were implanted with explanted DDD pulse generators programmed to VDD mode. Each implantation was planned and carried out according to a standard protocol. The age ranged from 45 to 75 (mean-61) years. The indications for pacing were complete heart block (4) and second degree AV block (1). The clinical profile, costs and complications, if any were noted and followed up at regular intervals. The results were compared with patients who received new DDD pulse generators during this period. The additional cost for the atrial lead was not required in these patients. None of these patients had any local site infection. Compared to the two-lead system, the single lead system provided more rapid implantation and minimized complications associated with placement of an atrial lead. The explanted DDD pacemaker can be safely reused as VDD mode with same efficacy in selected patient population. This is associated with lower cost and complications compared to reimplantation as DDD itself.  相似文献   

4.
Adult congenital heart disease patients may undergo numerous fluoroscopically guided procedures including pacemaker implantation during their lifetime. One alternative to traditional pacemaker setup which may improve long-term pacing outcomes is His bundle pacing. Given the altered His-bundle location, and given increased radiation exposure over a lifetime, we used 3-dimensional mapping to locate the His and to minimize fluoroscopy for placement of a His-bundle pacemaker system in a 31-year old patient with atrioventricular canal defect and complete heart block with 100% RV pacing and epicardial lead fracture.MethodsAn Octapolar Livewire catheter (Abbott, Minneapolis, USA) was used for mapping and location of the His bundle from a right femoral venous access on the EnSite Precision system 3-dimensional mapping system (Abbott Medical, Abbott Park, IL). The same map was used to guide 3830 lead placement into the posterior-inferior His-bundle position.ResultsSuccessful placement of a His-bundle pacing system with thresholds of 1Volt@0.4ms for both the atrial and ventricular leads with selective His-bundle pacing noted. Ten-month follow-up demonstrated His-bundle capture at 0.75V@0.4ms with stable impedance, sensing and with 100% right ventricular pacing a projected longevity of 12 years total.ConclusionsSuccessful placement of selective His-bundle pacing can be achieved in an adult patient with atrioventricular canal defect using 3-dimensional mapping.  相似文献   

5.
Torsade de Pointes (TdP) can be triggered by a pacing spike on the T-wave, due to pacemaker undersensing. However, it is not widely known that this phenomenon can occur even during pacemaker implantation. An 84-year-old woman underwent pacemaker implantation for the treatment of a complete atrioventricular block with dyspnea. During the procedure, immediately following ventricular lead insertion and before torque wrench tightening, TdP was observed. Ventricular pacing was initiated by inserting the lead into the header of the generator; however, sensing remained unstable. T-waves associated with undersensed PVCs and ventricular pacing occurred simultaneously, resulting in a spike on the T-wave and TdP.  相似文献   

6.
Out of a pacemaker clinic population of 182 patients 21 (11·5%) were found to have the sick sinus syndrome. Their ages ranged from 30 to 80 years and averaged 62. Ischaemic heart disease was more commonly an aetiological factor than in patients with chronic atrioventricular heart block. Other aetiologies were familial cardiomyopathy, postcardiac surgery, and dystrophia myotonica.Cardioversion before pacemaker insertion was a hazardous procedure. After insertion the occurrence of tachycardias and the need for drug therapy were reduced. One patient no longer required a pacemaker once atrial fibrillation became established.A high incidence of cerebral embolization was observed and the use of anticoagulant drugs therefore merits serious consideration.Failure of inhibition of demand-type pacemakers occurred in two patients. Two patients who exhibited competition with fixed-rate pacemakers died. Two patients were treated with electrodes surgically implanted on the right atrium. It is suggested that fixed-rate pacemakers may be contra-indicated and that sequential atrioventricular demand pacing is theoretically ideal.  相似文献   

7.
We present the case of a patient with a heart failure episode induced by acute right ventricular pacing. After reversal of beta-blockers because of chronic obstructive pulmonary disease (COPD) exacerbation, the following sinus tachycardia caused a 2:1 atrioventricular block and consequent continuous right ventricular pacing. He was treated with the selective I(f) inhibitor ivabradine, that reduced both ventricular pacing percentage and heart rate without affecting atrioventricular conduction. Ivabradine may be a valuable option in treatment of patients with atrioventricular conduction disturbances.  相似文献   

8.

Background

A complete, bidirectional conduction block in the cavotricuspid isthmus (CTI) represents the end-point of the typical atrial flutter ablation. We investigated the correlation between two criteria for successful ablation, one based on the atrial bipolar electrogram morphology before and after complete CTI conduction block, compared to the standard criteria of differential pacing and reversal in the right atrial depolarization sequence during coronary sinus (CS) pacing.

Method

We conducted a retrospective study in 111 patients (81 males, average age 62±10 years) who underwent an atrial flutter ablation during September 2007 - July 2009 in the Cardiology - Rehabilitation Hospital, UMF Cluj-Napoca. We assessed the presence of a bidirectional block at the end of the procedure using the standard criteria. We then analyzed the morphology of the bipolar atrial electrograms adjacent to the ablation line, before and after CTI conduction block.

Results

A change from a qRs morphology to a rSr'' morphology when pacing from the coronary sinus and from a rsr'' morphology to a QRS morphology when pacing from the low-lateral right atrium was associated with a CTI conduction block. Sensitivity (Se), specificity(Sp), positive predictive value (PPV), negative predictive value (NPV) were 96%, 89%, 99% and 67% respectively.

Conclusion

Our study suggests that the analysis of the atrial bipolar electrogram next to the ablation line before and after CTI ablation may be used as a reliable criterion to validate CTI conduction block due to its high sensitivity, specificity and positive predictive value.  相似文献   

9.
Left ventricular (LV) dysfunction can occur due to chronic right ventricular apical pacing. Upgrading of the pacemaker to biventricular pacing is an option to reverse LV dysfunction but reprogramming of the atrioventricular (AV) timing can also be favourable. In this case report we describe the effect of AV-time reprogramming in a patient with LV function deterioration that emerged two years after implantation of a dual chamber system for sick sinus syndrome. Echocardiographc studies demonstrated a tremendous improvement in LV function during two years follow-up whereas the percentage of right ventricular pacing diminished dramatically. Careful analysis of the cause of LV deterioration can avoid unnecessary upgrading to biventricular pacing. (Neth Heart J 2010;18:604–5.)  相似文献   

10.
目的:探讨起搏器术后新发房性心律失常的发生情况及其相关影响因素。方法:选择2006年1月至2007年12月于沈阳军区总医院首次植入永久起搏器的107例患者,男性50例,平均年龄65.0±11.9岁,术前通过追问病史及相关检查均排除房性心律失常(房颤、房扑、房速),术后平均随访3.9年,观察新发房性心律失常情况。按术后是否出现房性心律失常,将患者分为新发房性心律失常组和无房性心律失常组,比较两组患者术前和术后心脏超声结果的变化、心室起搏比例、起搏部位及起搏模式,并通过logistic回归分析起搏器术后发生房性心律失常的影响因素。结果:新发房性心律失常组26例(24.3%),其中房颤17例(15.9%),房扑2例(1.9%),房速7例(6.5%);无房性心律失常组81例。与无房性心律失常组比较,新发房性心律失常组左房内径明显增加(P=0.040)、二尖瓣返流程度较重(P=0.032)及左室射血分数明显下降(P=0.001),心室起搏百分比(VP%)显著升高(P=0.017)。心尖部起搏患者房性心律失常的发生率明显高于间隔部起搏(33.3%vs 16.9%,P<0.05),双腔起搏组患者房性心律失常发生率明显低于单腔起搏器组(18.7%vs 37.5%,P<0.05)。Logistic回归分析显示术后新发房性心律失常的发生与高比例的心室起搏(P=0.006)、VVI(R)起搏模式(P=0.014)及右心室起搏电极导线植于心尖部(P=0.024)显著相关。结论:起搏模式、心室起搏百分比、起搏部位是起搏器术后发生房性心律失常的影响因素。  相似文献   

11.

Aims

After decades of experience and strongly improved technology, service time of pacemaker generators is expected to increase. To test this hypothesis, we conducted a retrospective review of a large cohort of patients with a pacemaker.

Methods

We reviewed data collected between 1984 and 2006 in the first national Dutch pacemaker registry. This registry covered 96% of all generators implanted. We analysed the time of and reason for explantation of pacemaker generators. A 7-year follow-up interval after first implantation and following replacements was used to analyse changes over time.

Results

During 22 years of data collection, nearly 97,000 first pacemaker generators were implanted. A total of 27,937 (22.4%) generators were explanted within a mean of 6.3 (standard deviation 3.3) years. Reasons for approximately 60% of these explantations were ‘end of life’ of the pacemaker generator or elective system change. Complications or failures such as infections and recalls accounted for approximately 20% of the explantations. For the remaining 20%, the reasons for explantation had not been registered.

Conclusion

Despite progress in technology, a substantial proportion of pacemaker generators is explanted before its expected service time, with one in five generators being replaced due to technical failures, infections or other complications. Furthermore, the time interval between pacemaker implantation and explantation due to normal ‘end of life’ (battery EOL) decreased. Infections continue to rank highly as a cause for pacing system replacement, despite all current preventive measures.
  相似文献   

12.
OBJECTIVES--To determine the social costs of providing a rural population with radiology services under three different systems: the existing system (a small x ray unit at the remote site and all other examinations at the nearest radiology department (the host site)); a teleradiology system (most examinations at the remote site and more advanced examinations at the host site); and all examinations at the host site. DESIGN--Cost minimisation study. SETTING--Primary health care in a remote community in Norway. SUBJECTS--A randomly selected sample (n = 597) of all patients (n = 1793) having radiological examinations in 1993. MAIN OUTCOME MEASURES--Annual direct medical costs, direct non-medical (travel) costs, and indirect costs (lost production) of the three options. RESULTS--After exclusion of costs common to the three systems the direct medical, direct non-medical, and indirect costs of the three options were, respectively, 9000 pounds, 51,000 pounds, and 31,500 pounds (total 91,500 pounds) for the existing system; 108,000 pounds, 2,000 pounds, and 13,500 pounds (total 123,500 pounds) for the teleradiology option; and 0 pounds, 75,000 pounds, and 42,000 pounds (117,000 pounds in total) for the "all at host" option. Sensitivity analyses indicated that the existing system is the least costly option except when lost leisure is valued as highly as lost production. CONCLUSION--The teleradiology option did not seem to be cost saving in the study community. Such systems, however, may be justified on the grounds of equity of access and quality of care.  相似文献   

13.
OBJECTIVES--To cost a clinical unit over one month in 1991, to cost treatment of individual patients from audit data, and to compare this costing method with the hospital charging system. DESIGN--A financial breakdown was obtained for one month''s work. Ward stay, operating time, investigations, and outpatient visits were costed and a formula (episode = days on ward+hours of operating+investigations+outpatient visits) was used to cost patient episodes from audit data. SETTING--The adult urology unit in a teaching hospital. MAIN OUTCOME MEASURES--Costs for each part of patients'' treatment. RESULTS--Total cost was 147,796 pounds for 159 admissions, 738 inpatient days, 131 operations in 29 operating lists, and 615 outpatient visits. An uncomplicated transurethral prostatectomy cost 1140 pounds but complications increased this to 1500 pounds in another patient. The costs of diagnostic cystoscopy were 130 pounds in outpatients, 240 pounds in day surgery, and 430 pounds in inpatients. Hospital charges do not reflect the individual costs of treatment, charges being greater than costs for some patients and lower than costs for others. CONCLUSIONS--Clinicians can produce a financial analysis of their work and cost their patients'' treatment. Audit is strongly advocated as a resource planning tool.  相似文献   

14.
OBJECTIVES--To compare outcome and costs of general practitioners, senior house officers, and registrars treating patients who attended accident and emergency department with problems assessed at triage as being of primary care type. DESIGN--Prospective intervention study which was later costed. SETTING--Inner city accident and emergency department in south east London. SUBJECTS--4641 patients presenting with primary care problems: 1702 were seen by general practitioners, 2382 by senior house officers, and 557 by registrars. MAIN OUTCOME MEASURES--Satisfaction and outcome assessed in subsample of 565 patients 7-10 days after hospital attendance and aggregate costs of hospital care provided. RESULTS--Most patients expressed high levels of satisfaction with clinical assessment (430/562 (77%)), treatment (418/557 (75%)), and consulting doctor''s manner (434/492 (88%)). Patients'' reported outcome and use of general practice in 7-10 days after attendance were similar: 206/241 (85%), 224/263 (85%), and 52/59 (88%) of those seen by general practitioners, senior house officers, and registrars respectively were fully recovered or improving (chi2 = 0.35, P = 0.840), while 48/240 (20%), 48/268 (18%), and 12/57 (21%) respectively consulted a general practitioner or practice nurse (chi2 = 0.51, P = 0.774). Excluding costs of admissions, the average costs per case were 19.30 pounds, 17.97 pounds, and 11.70 pounds for senior house officers, registrars, and general practitioners respectively. With cost of admissions included, these costs were 58.25 pounds, 44.68 pounds, and 32.30 pounds respectively. CONCLUSION--Management of patients with primary care needs in accident and emergency department by general practitioners reduced costs with no apparent detrimental effect on outcome. These results support new role for general practitioners.  相似文献   

15.

Background

Postoperative junctional ectopic tachycardia (JET) occurs frequently after pediatric cardiac surgery. R-wave synchronized atrial (AVT) pacing is used to re-establish atrioventricular synchrony. AVT pacing is complex, with technical pitfalls. We sought to establish and to test a low-cost simulation model suitable for training and analysis in AVT pacing.

Methods

A simulation model was developed based on a JET simulator, a simulation doll, a cardiac monitor, and a pacemaker. A computer program simulated electrocardiograms. Ten experienced pediatric cardiologists tested the model. Their performance was analyzed using a testing protocol with 10 working steps.

Results

Four testers found the simulation model realistic; 6 found it very realistic. Nine claimed that the trial had improved their skills. All testers considered the model useful in teaching AVT pacing. The simulation test identified 5 working steps in which major mistakes in performance test may impede safe and effective AVT pacing and thus permitted specific training. The components of the model (exclusive monitor and pacemaker) cost less than $50. Assembly and training-session expenses were trivial.

Conclusions

A realistic, low-cost simulation model of AVT pacing is described. The model is suitable for teaching and analyzing AVT pacing technique.  相似文献   

16.
AimsOptimization of the AV-interval (AVI) in DDD pacemakers improves cardiac hemodynamics and reduces pacemaker syndromes. Manual optimization is typically not performed in clinical routine. In the present study we analyze the prevalence of E/A wave fusion and A wave truncation under resting conditions in 160 patients with complete AV block (AVB) under the pre-programmed AVI. We manually optimized sub-optimal AVI.MethodsWe analyzed 160 pacemaker patients with complete AVB, both in sinus rhythm (AV-sense; n = 129) and under atrial pacing (AV-pace; n = 31). Using Doppler analyses of the transmitral inflow we classified the nominal AVI as: a) normal, b) too long (E/A wave fusion) or c) too short (A wave truncation). In patients with a sub-optimal AVI, we performed manual optimization according to the recommendations of the American Society of Echocardiography.ResultsAll AVB patients with atrial pacing exhibited a normal transmitral inflow under the nominal AV-pace intervals (100%). In contrast, 25 AVB patients in sinus rhythm showed E/A wave fusion under the pre-programmed AV-sense intervals (19.4%; 95% confidence interval (CI): 12.6–26.2%). A wave truncations were not observed in any patient. All patients with a complete E/A wave fusion achieved a normal transmitral inflow after AV-sense interval reduction (mean optimized AVI: 79.4 ± 13.6 ms).ConclusionsGiven the rate of 19.4% (CI 12.6–26.2%) of patients with a too long nominal AV-sense interval, automatic algorithms may prove useful in improving cardiac hemodynamics, especially in the subgroup of atrially triggered pacemaker patients with AV node diseases.  相似文献   

17.
For purposes of correct treatment it is important to recognize that patients with complete atrioventricular dissociation fall into three groups: Group I—established third-degree heart block with and without Stokes-Adams attacks; Group II—periodic third-degree heart block with and without Stokes-Adams attacks; Group III—established third-degree heart block with cardiac failure. Most patients in Group I present no technical problems when a pacemaker is implanted. In Group II it is advisable to insert a temporary intracardiac catheter electrode and maintain a rate of 60 to 64 during the periods of third-degree heart block. Sudden reversion, in this group, from sinus rhythm can be fatal. Group III patients will often require a pacemaker set in excess of 74 beats until they are free of cardiac failure. Fifteen of 20 patients with complete atrioventricular dissociation showed marked functional improvement after insertion of a pacemaker. The development, in our laboratory, of a 4″ portable pacemaker impulse detector has been invaluable in locating the cause of failure in an implanted pacemaker.  相似文献   

18.
A novel rabbit model of variably compensated complete heart block.   总被引:2,自引:0,他引:2  
Complete heart block (CHB) provides a useful substrate for study of bradycardia-dependent ventricular arrhythmias and cardiac function. Existing CHB animal models are limited by surgical recovery time and reliance on intrinsic escape rhythms. We describe a novel closed-chest rabbit model of CHB involving transcatheter radiofrequency (RF) atrioventricular (AV) node ablation and ventricular rate control with chronic transvenous pacing. Permanent CHB was achieved in 34 of 38 attempts overall. Procedural mortality due to cardiac tamponade (n = 2), airway complications (n = 2), and unknown causes (n = 5) occurred in nine animals. Survivors with CHB (n = 28) were maintained for < or = 22 days, during which there were three late deaths related to infection (n = 1) or respiratory distress (n = 2). None of the survivors with CHB showed recovery of AV conduction or pacemaker capture loss during chronic ventricular pacing at about one-half normal sinus rates, and 25 animals surviving to death showed no overt signs of hemodynamic compromise such as lethargy, poor feeding, or respiratory distress. This approach provides a reproducible nonsurgical CHB model with adjustable ventricular rate control.  相似文献   

19.
OBJECTIVE--To measure costs and cost effectiveness of the British family heart study cardiovascular screening and intervention programme. DESIGN--Cost effectiveness analysis of randomised controlled trial. Clinical and resource use data taken from trial and unit cost data from external estimates. SETTING--13 general practices across Britain. SUBJECTS--4185 men aged 40-59 and their 2827 partners. INTERVENTION--Nurse led programme using a family centered approach, with follow up according to degree of risk. MAIN OUTCOME MEASURES--Cost of the programme it self; overall short term cost to NHS; cost per 1% reduction in coronary risk at one year. RESULTS--Estimated cost of putting the programme into practice for one year was 63 pounds per person (95% confidence interval 60 pounds to 65 pounds). The overall short term cost to the health service was 77 pounds per man (29 pounds to 124 pounds) but only 13 pounds per woman (-48 pounds to 74 pounds), owing to differences in utilisation of other health service resources. The cost per 1% reduction in risk was 5.08 pounds per man (5.92 pounds including broader health service costs) and 5.78 pounds per woman (1.28 pounds taking into account wider health service savings). CONCLUSIONS--The direct cost of the programme to a four partner practice of 7500 patients would be approximately 58,000 pounds. Annually, 8300 pounds would currently be paid to a practice of this size working to the maximum target on the health promotion bands, plus any additional reimbursement of practice staff salaries for which the practice qualified. The broader short term costs to the NHS may augment these costs for men but offset them considerably for women.  相似文献   

20.

Background

The use of magnetic resonance imaging (MRI)-conditional permanent pacemakers has increased significantly. In this meta-analysis, we examine the safety of MRI-conditional pacing systems in comparison with conventional systems.

Methods

An electronic search was performed using major databases, including studies that compared the outcomes of interest between patients receiving MRI-conditional pacemakers (MRI group) versus conventional pacemakers (control group).

Results

Six studies (5 retrospective and 1 prospective non-randomised) involving 2,118 adult patients were identified. The MRI-conditional pacemakers, deployed in 969 patients, were all from a single manufacturer (Medtronic Pacing System with 5086 leads). The rate of pacemaker lead dislodgement (atrial and ventricular) was significantly higher in the MRI group (3% vs. 1%, OR 2.47 (95% CI 1.26; 4.83), p?=?0.008). The MRI group had a significantly higher rate of pericardial complications (2% vs. 1%, OR 4.23 (95% CI 1.18; 15.10), p?=?0.03) and a numerically higher overall complication rate in comparison with the conventional group (6% vs. 3%, OR 2.02 (95% CI 0.88; 4.66), p?=?0.10) but this was not statistically significant.

Conclusions

In this meta-analysis, the rates of pacemaker lead dislodgement and pericardial complications were significantly higher with the Medtronic MRI-conditional pacing system.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号