首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We discuss initial magnetic field strength measurements made around radiofrequency (RF) induction heaters. These measurements were made with a monitor developed for the National Institute for Occupational Safety and Health (NIOSH) by the National Bureau of Standards (NBS). The monitor has a dynamic range of .01 to 10,000 A2/m2, a frequency range of 300 kHz to 100 MHz, an isotropic response (+/- .3 dB) with three mutally orthogonal loop antennas that have the ability to measure and display each of three orthogonal magnetic field components, a high probe burnout protection level of 20,000 A2/m2, and an accuracy of +/- 1.0 dB at 13 calibration frequencies. The portable survey monitor was used to measure the magnetic field strengths in the vicinity of 16 RF induction heaters. Typically these induction heaters are operated continuously for several hours. The maximum field strengths (without duty factor correction) ranged from 15 to 4,500 A2/m2 and were measured 5 to 51 cm from the loop applicators of the induction heaters. At locations commonly occupied by workers (ie, approximately 30 to 76 cm from heaters), the fields ranged from .01 to 300 A2/m2 (without duty factor correction).  相似文献   

2.
Recent laboratory and epidemiological results have stimulated interest in the hypothesis that human beings may exhibit biological responses to magnetic and/or electric field transients with frequencies in the range between 100 Hz and 100 kHz. Much can be learned about the response of a system to a transient stimulation by understanding its response to sinusoidal disturbances over the entire frequency range of interest. Thus, the main effort of this paper was to compare the strengths of the electric fields induced in homogeneous ellipsoidal models by uniform 100 Hz through 100 kHz electric and magnetic fields. Over this frequency range, external electric fields of about 25–2000 V/m (depending primarily on the orientation of the body relative to the field) are required to induce electric fields inside models of adults and children that are similar in strength to those induced by an external 1 μT magnetic field. Additional analysis indicates that electric fields induced by uniform external electric and magnetic fields and by the nonuniform electric and magnetic fields produced by idealized point sources will not differ by more than a factor of two until the sources are brought close to the body. Published data on electric and magnetic field transients in residential environments indicate that, for most field orientations, the magnetic component will induce stronger electric fields inside adults and children than the electric component. This conclusion is also true for the currents induced in humans by typical levels of 60 Hz electric and magnetic fields in U.S. residences. Bioelectromagnetics 18:67–76, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

3.
4.
Data are presented on ankle-specific SARs and foot currents as a function of strengths of radio-frequency electromagnetic fields encountered by operators of dielectric heaters. The determination of foot currents was based on near-field exposures in which reactive coupling dominates, and which can result in substantial SARs in exposed workers. The operators were located less than one wavelength from--usually within one meter of--the dielectric heaters, which generated fields at frequencies from 6.5 to 65 MHz. At distances normally assumed by workers, maximal strengths of electric fields ranged from 10(4) to 2.4 x 10(6) V2/m2; maximal strengths of magnetic fields ranged from 5.0 x 10(-3) to 33.3 A2/m2. Currents through both feet to ground were measured while operators stood where they normally worked. Maximal currents ranged from 3 to 617 mA, rms. Nearly 27 percent of the dielectric heaters induced foot currents that exceeded the 200-mA limit that has been proposed for a new ANSI C95.1 standard. Twenty percent of the heaters induced foot currents that exceeded 350 mA. SARs in ankles were calculated from foot currents, and they approximated 5 W/kg at 100 mA, 29 W/kg at 250 mA, and 57 W/kg at 350 mA. The maximal SAR in the ankle was approximately 176 W/kg at 617 mA.  相似文献   

5.
The main purpose of this work was to investigate the fluctuation of Greek indoor electromagnetic field (EMF) intensity values and identify peaks that might occur. The scientific interest is mainly focused on the bands of extremely low-frequency (ELF) magnetic fields and radiofrequency (RF) electric fields which have been suggested to be possibly carcinogenic to humans by the Scientific Committee on Emerging and Newly Identified Health Risks (SCENIHR).Electromagnetic radiation (EMR) measurements were performed in a variety of indoor dwellings, in Attica and in the islands of Zakynthos and Lesvos.A total number of 4540 measurements were taken in a wide frequency range (50 Hz–2100 MHz) of which 3301 in Attica, 963 in Lesvos and 276 in Zakynthos.Statistical analysis of the data revealed specific statistically significant differences between the mean values of the electric (ELF and RF) but not the magnetic (ELF) field strengths measured at different distances from the EMF source, as well as between some of the mean values of the RF electric field at different bands. Some statistically significant differences between mean electric field values at different geographic locations were also identified.As far as the RF electric field is concerned, the maximum values, in most cases, were below 0.5 V/m, however increased values above 1 V/m and up to 5.6 V/m were occasionally observed. The ELF magnetic field values were lower than 1 μT. It may be concluded that overall, the observed indoor EMF intensity values remained well below domestic and European established limits.  相似文献   

6.
Summary Chick embryos were exposed during their 48 first hours of development to sinusoidally oscillating magnetic fields. The frequencies 1 Hz, 10 Hz, 16.7 Hz, 30 Hz, 50 Hz, 1 kHz, 10 kHz and 100 kHz, and the field strengths 0.1, 1, 10 and 100 A/m were used. Each exposure group consisted of 20 eggs. After the exposure, the embryos were examined for abnormalities and classified by the developmental stage. The percentage of abnormal embryos (%AE) was significantly increased at frequencies from 16.7 Hz to 100 kHz. Above a threshold field strength of about 0.1 to 1 A/m, %AE was rather independent of the field strength, varying from 16% to 56% in different exposure groups. 13% of the sham-exposed control embryos (n = 150) were abnormal. Only the 0.1 A/m exposure group differed significantly from the controls at 1 Hz, and no significant effect was found at 10 Hz. The developmental stage was in general not affected by the magnetic fields, but some abnormal embryos showed retarded development.  相似文献   

7.
Summary By using several biophysical approximations and considering man as free space model limiting order-of-magnitude values for external electric and magnetic field strengths which may be hazardous for human beings were calculated. Danger may occur by excitation processes below 30 kHz for field strengths exceeding these limiting values; for frequencies larger than 30 kHz, thermal effects are predominant before excitation occurs. The external electric field strength necessary for causing action potentials in the central nervous system exceeds by far the corona forming level. But excitation is possible by strong alternating magnetic fields.Furthermore, by comparing the electrically and magnetically induced currents with the naturally flowing currents in man caused by the brain's and heart's electrical activity, a lower boundary-line was estimated. Regarding electric or magnetic field strengths undercutting this boundary-line, direct effects on the central nervous system may be excluded. Other mechanisms should be responsible for demonstrated biological effects.  相似文献   

8.
We have plotted data from a number of studies on the range of radiofrequency (RF) field levels associated with a variety of environmental and occupational sources. Field intensity is shown in units of volts/meter (V/m) for electric field strength and amps/meter (A/m) for magnetic field strength. Duty factors, modulation frequencies, and modulation indices are also reported for some sources. This paper is organized into seven sections, each cataloging sources into appropriate RF frequency bands from very-low frequency (VLF) to super-high frequency (SHF), and covers frequencies from 10 kHz to 30 GHz. Sources included in this summary are the following: Coast Guard navigational transmitters, a Navy VLF transmitter, computer visual display terminals (VDTs), induction stoves or range tops, industrial induction and dielectric heaters, radio and television broadcast transmitters, amateur and citizens band (CB) transmitters, medical diathermy and electrosurgical units, mobile and handheld transmitters, cordless and cellular telephones, microwave ovens, microwave terrestrial relay and satellite uplinks, and police, air traffic, and aircraft onboard radars. For the sources included in this summary, the strongest fields are found near industrial induction and dielectric heaters, and close to the radiating elements or transmitter leads of high power antenna systems. Handheld transmitters can produce near fields of about 500 V/m at the antenna. Fields in the general urban environment are principally associated with radio and TV broadcast services and measure about 0.1 V/m root-mean-square (rms). Peak fields from air traffic radars sampled in one urban environment were about 10 V/m, 300 times greater than the rms value of 0.03 V/m when the duty factor associated with antenna rotation and pulsing are factored in. Bioelectromagnetics 18: 563–577, 1997. Published 1997 Wiley-Liss, Inc.
  • 1 This article is a US Government work and, as such, is in the public domain in the United States of America.
  •   相似文献   

    9.
    Electromagnetic field exposure and health among RF plastic sealer operators   总被引:2,自引:0,他引:2  
    Operators of RF plastic sealers (RF operators) are an occupational category highly exposed to radiofrequency electromagnetic fields. The aim of the present study was to make an appropriate exposure assessment of RF welding and examine the health status of the operators. In total, 35 RF operators and 37 controls were included. The leakage fields (electric and magnetic field strength) were measured, as well as induced and contact current. Information about welding time and productivity was used to calculate time integrated exposure. A neurophysiological examination and 24 h ECG were also carried out. The participants also had to answer a questionnaire about subjective symptoms. The measurements showed that RF operators were exposed to rather intense electric and magnetic fields. The mean values of the calculated 6 min, spatially averaged E and H field strengths, in line with ICNIRP reference levels, are 107 V/m and 0.24 A/m, respectively. The maximum measured field strengths were 2 kV/m and 1.5 A/m, respectively. The induced current in ankles and wrists varied, depending on the work situation, with a mean value of 101 mA and a maximum measured value of 1 A. In total, 11 out of 46 measured RF plastic sealers exceeded the ICNIRP reference levels. RF operators, especially the ready made clothing workers had a slightly disturbed two-point discrimination ability compared to a control group. A nonsignificant difference between RF operators and controls was found in the prevalence of subjective symptoms, but the time integrated exposure parameters seem to be of importance to the prevalence of some subjective symptoms: fatigue, headaches, and warmth sensations in the hands. Further, RF operators had a significantly lower heart rate (24 h registration) and more episodes of bradycardia compared to controls.  相似文献   

    10.
    The action on intracellular cyclic AMP (cAMP) of therapeutically used 4000-Hz electric fields was investigated and compared with 50-Hz data. Cultured mouse fibroblasts were exposed for 5 minutes to 4000-Hz sine wave internal electric fields between 3 mV/m and 30 V/m applied within culture medium. A statistically significant decrease in cellular cAMP concentration relative to unexposed cells was observed for fields higher than 10 mV/m. The drop in cAMP was most pronounced at lower field strengths (71 % of controls at 30 mV/m) and tended to disappear at higher field strengths. An increase of cAMP content was observed with 50-Hz electric fields, as was also the case when 4000-Hz fields were modulated with certain low frequencies.  相似文献   

    11.
    A laboratory facility specifically designed for controlled human exposure to 60-Hz electric (0 to 16 kV/m) and magnetic (0 to 32 A/m, B = 0 to 40 microT) fields has been constructed. The facility presents uniform fields under controlled temperature and humidity. Special control systems allow collection of physiological data during, as well as before and after, exposure to electric fields at strengths to 16 kV/m under verified double-blind control. Exposure to continuous or intermittent fields is possible in the facility. The capability of obtaining physiological data during actual exposure to constant or intermittent, 60-Hz fields, and of doing so without either the subject or the experimenter being aware of actual field conditions, is a critical factor in valid experimentation.  相似文献   

    12.
    We have developed an intermediate frequency (IF) magnetic field exposure system for in vitro studies. Since there are no previous studies on exposure to heating-frequency magnetic fields generated from an induction heating (IH) cook top, there is a strong need for such an exposure system and for biological studies of IF magnetic fields. This system mainly consists of a magnetic-field-generating coil housed inside an incubator, inside which cultured cells can be exposed to magnetic field. Two systems were prepared to allow the experiment to be conducted in a double-blind manner. The level of the generated magnetic field was set to 532 microT rms in the exposure space, 23 kHz, 80 times the value in the International Commission on Non-ionizing Radiation Protection (ICNIRP) guidelines, with a spatial field uniformity better than 3.8%. The waveforms were nearly sinusoidal. It was also confirmed that the parasitic electric field was 157 V/m rms and the induced electric field was 1.9 V/m rms. The temperature was maintained at 36.5 +/- 0.5 degrees C for 2 h. Furthermore, leaked magnetic flux density was 0.7 microT rms or lower at extremely low frequency (ELF) and IF in the stopped system when the other system was being operated, and the environmental magnetic flux density was 0.1 microT rms or lower at the center of the coils. As a result, it was confirmed that this system could be successfully used to evaluate the biological effects of exposure to IF magnetic fields.  相似文献   

    13.
    Exposure to man-made electromagnetic fields has increased over the past century. As a result of exposure to these fields, concerns have been raised regarding the relationship between electromagnetic fields and human health. Interest in the biological and health effects of intermediate frequency (IF) magnetic fields has grown recently because of the increase in public concern. In order to investigate whether IF magnetic fields have biological effects, we have developed a 20 kHz (IF) magnetic field exposure system for in vivo studies. The exposure facility was designed to study the biological effects of IF magnetic field on laboratory animals. The facility consists of a 9 m x 9 m x 5 m high room containing seven separate rooms including a 5.3 m x 4.5 m x 3 m high specific-pathogen free exposure room. The dimensions of the exposure system are 1.6 m x 1.6 m x 1.616 m high located inside this exposure room. The system is designed to provide magnetic fields up to 200 microT at 20 kHz with the uniformity within +/-5% over the space occupied by animals. After constructing the facility, performance tests were carried out. As a result, it was confirmed that our facility met requirements for evaluation of the biological effects of IF magnetic field on small animal experiments. In this paper, the design, construction, and results of evaluation of an animal exposure facility for the in vivo biological effects of an IF magnetic field are described.  相似文献   

    14.
    A miniaturized probe was designed and built to provide detailed data on fields induced by a uniform 60-Hz magnetic field in homogeneous models of rat and human. The probe employed three silver wires twisted and potted in an 8-cm hypodermic needle. The exposed tips of the wires formed three sensing electrodes with a centered ground; highly sensitive voltage measurements were enabled by a lock-in amplifier. Tests were conducted in a 1-mT rms field that was uniform within +/- 5%. The models were made by casting 1.5% agar at 1-S/m conductivity into plastic-foam molds. The rat model was scaled 1:1 as an adult (22 cm length; mass about 640 g). The human model was scaled 1:4 as an adult (height = 46.5 cm; mass 1.4 kg). The probe was inserted into each model in several regions, and readings of induced fields were made under different exposure geometries. Maximal strengths of fields induced near the surface of the torso were as high as 120 microV/cm in the laterally exposed rat model. Data extrapolated from the quarter-scale human model revealed that an induced field as high as 700 microV/cm could occur at the torso of a frontally exposed human adult. An overall size-scale factor of about 5 appears to be appropriate for experimental exposures of rats that are intended to simulate currents induced in human beings by magnetic fields. The average strength of electric fields induced in the torso by a 1-mT magnetic field is comparable to that by a vertical electric-field at 60 kV/m and 28 kV/m, respectively, for the rat and human.  相似文献   

    15.
    A system is described that uses an oscillating magnetic field to produce power-frequency electric fields with strengths in excess of those produced in an animal or human standing under a high-voltage electric-power transmission line. In contrast to other types of exposure systems capable of generating fields of this size, no electrodes are placed in the conducting growth media: the possibility of electrode contamination of the exposed suspension is thereby eliminated. Electric fields in the range 0.02–3.5 V/m can be produced in a cell culture with total harmonic distortions less than 1.5%. The magnetic field used to produce electric fields for exposure is largely confined within a closed ferromagnetic circuit, and experimental and control cells are exposed to leakage magnetic flux densities less than 5 μT. The temperatures of the experimental and control cell suspensions are held fixed within ±0.1°C by a water bath. Special chambers were developed to hold cell cultures during exposure and sham exposure. Chinese hamster ovary (CHO) cells incubated in these chambers grew for at least 48 h and had population doubling times of 16–17 h, approximately the same as for CHO cells grown under standard cell-culture conditions.  相似文献   

    16.
    Transverse electric and magnetic field (TEM) cells are often designed to subject samples to electromagnetic radiation of intrinsic impedance (E/H) that is the same as in free space, 377 omega. Earlier work has shown this value to be correct for the RF region above about 2 kHz. In this study, measurements of magnetic fields in the extremely low frequency regions and at DC indicate the E/H ratio to be around 300 omega for frequencies less than 2 kHz in cells of a particular design. This lower value indicates that care should be taken in estimating AC magnetic field intensities from electric field measurements in TEM cells at frequencies below 2 kHz.  相似文献   

    17.
    Power-frequency electric and magnetic fields are known to exhibit marked temporal variation, yet in the absence of clear biological indications, the most appropriate summary indices for use in epidemiologic studies are unknown. In order to assess the statistical patterns among candidate indices, data on 4383 worker-days for magnetic fields and 2082 worker-days for electric fields collected for the Electric and Magnetic Field Project for Electric Utilities using the EMDEX meter [Bracken (1990): Palo Alto, CA: Electric Power Research Institute] were analyzed. We examined correlations at the individual and job title group levels among indices of exposure to both electric and magnetic fields, including the arithmetic mean, geometric mean, median, 20th and 90th percentiles, time above lower cutoffs of 20 V/m and 0.2 μT, and time above higher cutoffs of 100 V/m and 2.0 μT. For both electric and magnetic fields, the arithmetic mean was highly correlated with the 90th percentile; moderately correlated with the geometric mean, median, and lower and higher cutoff scores; and weakly correlated with the 20th percentile. Electric and magnetic field indices were generally weakly correlated with one another. Rank-order correlation coefficients were consistently greater than product-moment correlation coefficients. Job title group summary scores showed higher correlations among electric field indices and magnetic field indices and between electric and magnetic field indices than was found for individual worker-days, with only the 20th percentile clearly independent of the others. These results suggest that individuals' exposures are adequately characterized by a measure of central tendency for electric and magnetic fields, such as the arithmetic or geometric mean, and an indicator of a lower threshold or cutoff for each field type, such as the 20th percentile or proportion of time above 20 V/m or 0.2 μT. A single measure of central tendency for each type of field appears to be adequate when exposures are assessed at the job title level. © 1994 Wiley-Liss, Inc.  相似文献   

    18.
    Extremely low frequency magnetic fields interact with an animal by inducing internal electric fields, which are in addition to the normal endogenous fields present in living animals. Male rats weighing about 560 g each were anesthetized with ketamine and xylazine. Small incisions were made in the ventral body wall at the chest and upper abdomen to position a miniature probe for measuring internal electric fields. The calibration constant for the probe size was 5.7 mm, with a flat response from at least 12 Hz to 20 kHz. A cardiac signal, similar to the normal electrocardiogram with a heart rate of about 250 bpm, was readily obtained at the chest. Upon analysis of its spectrum, the cardiac field detected by the probe had a broad maximum at 32–95 Hz. When the rats were exposed to a 1 mT, 60 Hz magnetic field, a spike appeared in the spectrum at 60 Hz. The peak-to-peak magnitudes of electric fields associated with normal heart function were comparable to fields induced by a 1 mT magnetic field at 60 Hz for those positions measured on the body surface (where induced fields were maximal). Within the body, or in different directions relative to the applied field, the induced fields were reduced (reaching zero at the center of the animal). The cardiac field increased near the heart, becoming much larger than the induced field. Thus, the cardiac electric field, together with the other endogenous fields, combine with induced electric fields and help to provide reference levels for the induced-field dosimetry of ELF magnetic field exposures of living animals. Bioelectromagnetics 18:317–323, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

    19.
    A system is described that is capable of producing extremely low frequency (ELF) magnetic fields for relatively short-term exposure of cultured mammalian cells. The system utilizes a ferromagnetic core to contain and direct the magnetic field of a 1,000 turn solenoidal coil and can produce a range of flux densities and induced electric fields much higher than those produced by Helmholtz coils. The system can generate magnetic fields from the microtesla (μT) range up to 0.14 T with induced electric field strengths on the order of 1.0 V/m. The induced electric field can be accurately varied by changing the sample chamber configuration without changing the exposure magnetic field. This gives the system the ability to separate the bioeffects of magnetic and induced electric fields. In the frequency range of 4–100 Hz and magnetic flux density range of 0.005–0.14 T, the maximum total harmonic distortion of the induced electric field is typically less than 1.0%. The temperature of the samples is held constant to within 0.4°C by constant perfusion of warmed culture medium through the sample chamber. © 1993 Wiley-Liss, Inc.  相似文献   

    20.
    Magnetic field systems were added to existing electric field exposure apparatuses for exposing cell suspensions in vitro and small animals in vivo. Two horizontally oriented, rectangular coils, stacked one directly above the other, have opposite electric currents. This configuration minimizes leakage fields and allows sham- and field-exposure systems to be placed in the same room or incubator. For the in vitro system, copper plates formed the loop-pair, with up to 900 A supplied by a 180:1 transformer. Electric fields were supplied via electrodes at the ends of cell-culture tubes, eight of which can be accommodated by each exposure system. Two complete systems are situated in an incubator to allow simultaneous sham and field exposure up to 1 mT. For the in vivo system, four pairs of 0.8 x 2.7-m coils made of copper bus bar are employed. This arrangement is energized from the power grid via a 30:1 transformer; horizontal magnetic flux densities up to 1 mT can be generated. Pairs of electrode plates spaced 30.5 cm apart provide electric field exposure of up to 130 kV/m. Four systems with a capacity of 48 rats each are located in one room. For both the in vitro and in vivo systems, magnetic exposure fields are uniform to within +/- 2.5%, and sham levels are at least 2,500-fold lower than exposure levels. Potential confounding factors, such as heating and vibration, were examined and found to be minimal.  相似文献   

    设为首页 | 免责声明 | 关于勤云 | 加入收藏