首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chen H  Xu Z  Xu N  Cen P 《Journal of biotechnology》2005,115(3):307-315
Human beta-defensin-2 (hBD2), a small cationic peptide, exhibits a broad range of antimicrobial activity and does not cause microbial resistance. In order to produce hBD2 efficiently, an Escherichia coli cell-free biosynthesis system has been developed as an alternative method. A specific plasmid pIVEX2.4c-trxA-shBD2 was constructed for the cell-free expression of fusion protein (hBD2 linked with His-Tag and Trx-Tag). This allowed enhancement of protein stability and facilitated downstream purification process. Significant amount of target fusion protein was synthesized in the batch-mode bioreactor by optimizing the reaction conditions. About five-fold improvement of productivity (ca. 2.0 mg/ml soluble fusion protein) could be achieved by using a continuous exchange cell-free (CECF) system compared to batch system. One-step affinity chromatographic process was developed to recover high purity fusion protein (95.2%) with overall recovery ratio of about 50%. The fusion protein was cleaved by cyanogens bromide (CNBr), and the mature hBD2 had demonstrated strong inhibition on the growth of E. coli D31 at low concentration.  相似文献   

2.
A high-throughput bioanalytical method based on automated sample transfer, automated solid phase extraction, and hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) analysis, has been developed for the determination of cetirizine, a selective H(1)-receptor antagonist. Deuterated cetirizine (cetirizine-d(8)) was synthesized as described and was used as the internal standard. Samples were transferred into 96-well plates using an automated sample handling system. Automated solid phase extraction was carried out using a 96-channel programmable liquid-handling workstation. Solid phase extraction 96-well plate on polymer sorbent (Strata X) was used to extract the analyte. The extracted samples were injected onto a Betasil silica column (50 x 3, 5 microm) using a mobile phase of acetonitrile-water-acetic acid-trifluroacetic acid (93:7:1:0.025, v/v/v/v) at a flow rate of 0.5 ml/min. The chromatographic run time is 2.0 min per injection, with retention time of cetirizine and cetirizine-d(8) both at 1.1 min. The system consisted of a Shimadzu HPLC system and a PE Sciex API 3000 or API 4000 tandem mass spectrometer with (+) ESI. The method has been validated over the concentration range of 1.00-1000 ng/ml cetirizine in human plasma, based on a 0.10-ml sample size. The inter-day precision and accuracy of the quality control (QC) samples demonstrated <3.0% relative standard deviation (R.S.D.) and <6.0% relative error (RE). Stability of cetirizine in stock solution, in plasma, and in reconstitution solution was established. The absolute extraction recovery was 85.8%, 84.5%, and 88.0% at 3, 40, and 800 ng/ml, respectively. The recovery for the internal standard was 84.1%. No adverse matrix effects were noticed for this assay. The automation of the sample preparation steps not only increased the analysis throughput, but also increased method ruggedness. The use of a stable isotope-labeled internal standard further improved the method ruggedness. Practical issues of analyzing incurred samples were discussed. This HILIC-MS/MS method for analysis of citirizine in human plasma was successfully used to support clinical studies.  相似文献   

3.
The ability of peptides coded by the anti-sense strand of DNA to interact specifically with peptides coded by the sense strand has been evaluated. The sense peptide examined, ribonuclease S-peptide, was immobilized on a coated silica affinity chromatographic matrix. Anti-sense peptides were synthesized on the basis of the anti-sense DNA sequence for the S-peptide region in native pancreatic ribonuclease A. The interaction of synthetic anti-sense peptides with sense peptide was quantitated from the degree of retardation during chromatographic elution on the sense peptide affinity matrix in buffers with and without soluble competing sense peptide. Sense/anti-sense peptide interactions were found to occur with significant affinities with each of two anti-sense 20-residue peptides of opposite amino-to-carboxyl orientations and to weaken progressively with decreasing length of anti-sense peptide. The substantial chromatographic retardation of anti-sense peptides was specific, since it decreased as expected with increasing concentration of the soluble competing S-peptide, could not be mimicked by the elution of several control peptides (including S-peptide itself) on the S-peptide matrix, and did not occur with a blank chromatographic matrix (no S-peptide attached). The stoichiometry of anti-sense peptide binding to immobilized sense peptide was found to be far greater than 1:1, and at least 4-5:1, for the two 20-mer anti-sense peptides. In sum, the analytical affinity chromatographic experiments have established quantitatively that anti-sense peptide binding to sense peptides occurs in the ribonuclease S-peptide case and have identified some structural elements that govern these interactions.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

4.
大肠杆菌表达重组蛋白相比真核细胞具有成本低廉、大规模发酵容易、条件易于自动化控制等优点,通过大肠杆菌表达重组蛋白是一种高效、经济的途径,重组蛋白表达量可达到大肠杆菌总蛋白质量的50%。具有正常生化活性的重组蛋白通常为可溶性形式,因而对于以得到活性产物(如抗体、酶等)为目的的研究,通常采用可溶性表达途径。目前已有多种以可溶性重组蛋白为活性物质的治疗性药物经批准上市,但并非所有外源基因均能实现可溶性高表达,因此重组蛋白的可溶性高表达具有重要研究价值。在总结近年提高经大肠杆菌可溶性表达重组蛋白产率研究的基础上,从启动子的选择、SD序列的引入、信号肽的优化、宿主细胞的选择、共表达其他蛋白质,高密度发酵等方面阐释在大肠杆菌中提高可溶性重组蛋白表达产率的方法。  相似文献   

5.
We have investigated the specificity of a chloroplast soluble processing enzyme that cleaves the precursor of the major light-harvesting chlorophyll a/b binding protein (LHCP). The precursor of LHCP (preLHCP) was synthesized in Escherichia coli and recovered from inclusion-like bodies. It was found to be a substrate for proteolytic cleavage by the soluble enzyme in an organelle-free reaction, yielding a 25 kilodalton peptide. This peptide co-migrated during sodium dodecyl sulfate-polyacrylamide gel electrophoresis with the smaller of the forms (25 and 26 kilodalton) produced when either the E. coli-synthesized precursor, or preLHCP made in a reticulocyte lysate, was imported into chloroplasts. N-Terminal sequence analysis of the E. coli-generated precursor showed that it lacked an N-terminal methionine. N-Terminal sequencing of the 25 kilodalton peptide produced in the organelle-free reaction indicated that processing occurred between residues 40 and 41, removing a basic domain (RKTAAK) thought to be at the N-terminus of all LHCP molecules of type I associated with photosystem II. To determine if the soluble enzyme involved also cleaves other precursor polypeptides, or is specific to preLHCP, it was partially purified, and the precursors for Rubisco small subunit, plastocyanin, Rubisco activase, heat shock protein 21, and acyl carrier protein were tested as substrates. All of these precursors were cleaved by the same chromatographic peak of activity that processes preLHCP in the organelle-free reaction.  相似文献   

6.
To express an increased level of recombinant Mefp1 (marine mussel adhesive protein) in soluble form, we constructed expression vectors encoding truncated OmpA signal peptide-Mefp1 fusion proteins. OmpA signal peptide (OmpASP) is the 21 residue peptide fragment of the 23 residue OmpA signal sequence cleavable by signal peptidase I. We successfully produced increased levels of soluble recombinant Mefp1 (rMefp1) with various deletions of OmpASP, and found that the increased expression was caused by the increased pI of the N-terminus of the fusion proteins (> or = 10.55). All the OmpA signal peptide segments of 3-21 amino acids in length had the same pI value (10.55). Our results suggest that the pI value of the truncated OmpASP (OmpASP(tr)) play an important role in directional signaling for the fusion protein, but we found no evidence for the presence of a secretion enhancer in OmpASP. For practical applications, we increased the expression of soluble rMefp1 with OmpASP(tr) peptides as directional signals, and obtained rMefp1 with the native amino terminus (nN-rMefp1) using an OmpASP(tr)| Xa leader sequence that contains the recognition site for Xa protease.  相似文献   

7.
The balance between chromatographic performance and mass spectrometric response has been evaluated using an automated series of experiments where separations are produced by the real-time automated blending of water with organic and acidic modifiers. In this work, the concentration effects of two acidic modifiers (formic acid and trifluoroacetic acid) were studied on the separation selectivity, ultraviolet, and mass spectrometry detector response, using a complex peptide mixture. Peptide retention selectivity differences were apparent between the two modifiers, and under the conditions studied, trifluoroacetic acid produced slightly narrower (more concentrated) peaks, but significantly higher electrospray mass spectrometry suppression. Trifluoroacetic acid suppression of electrospray signal and influence on peptide retention and selectivity was dominant when mixtures of the two modifiers were analyzed. Our experimental results indicate that in analyses where the analyzed components are roughly equimolar (e.g., a peptide map of a recombinant protein), the selectivity of peptide separations can be optimized by choice and concentration of acidic modifier, without compromising the ability to obtain effective sequence coverage of a protein. In some cases, these selectivity differences were explored further, and a rational basis for differentiating acidic modifier effects from the underlying peptide sequences is described.  相似文献   

8.
A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.  相似文献   

9.
A completely automated peptide mapping liquid chromatography/mass spectrometry (LC/MS) system for characterization of therapeutic proteins in which a common high-performance liquid chromatography (HPLC) autosampler is used for automated sample preparation, including protein denaturation, reduction, alkylation, and enzymatic digestion, is described. The digested protein samples are then automatically subjected to LC/MS analysis using the same HPLC system. The system was used for peptide mapping of monoclonal antibodies (mAbs), known as a challenging group of therapeutic proteins for achieving complete coverage and quantitative representation of all peptides. Detailed sample preparation protocols, using an Agilent HPLC system, are described for Lys-C digestion of mAbs with intact disulfide bonds and tryptic digestion of mAbs after reduction and alkylation. The automated procedure of Lys-C digestion of nonreduced antibody, followed by postdigestion disulfide reduction, produces both the nonreduced and reduced digests that facilitate disulfide linkage analysis. The automated peptide mapping LC/MS system has great utility in preparing and analyzing multiple samples for protein characterization, identification, and quantification of posttranslational modifications during process and formulation development as well as for protein identity and quality control.  相似文献   

10.
During the course of large scale purification of the D1 dopamine receptor from rat brain, a protein of approximately 87,000 daltons (p87) was observed to copurify with the D1 receptor through four chromatographic steps. To characterize the nature of this protein, bovine and rat cDNA clones were isolated and sequenced. The bovine and rat clones were highly conserved (98.5% identity). Each clone possessed an open reading frame of 2226 base pairs encoding a protein of 742 amino acids (calculated MW of 82,500), containing three stretches of peptide sequence obtained from p87 sequence analysis. Comparison of the deduced peptide sequence of this protein with those found in available databanks revealed that it was a novel protein related to the family of nutrient transport proteins from eukaryotes and bacteria, including, the mammalian facilitated glucose transporters, the yeast transporters for maltose, lactose, and glucose, and the proton-driven bacterial transporters for arabinose, xylose, and citrate. In addition p87 also shares with these transporters a similar hydropathicity profile that suggests the presence of 12 transmembrane segments. The mRNA for p87 appears to be localized primarily, if not exclusively, to the central nervous system. Northern blot analysis reveals a message of approximately 4.8 kb in cortex, hippocampus, brain stem, and cerebellum, but no detectable signal in peripheral tissues such as spleen, liver, kidney, lung, heart, or skeletal muscle. Evidence form Western blot analysis and immunohistochemistry suggests that this protein may be expressed in intracellular organelles or the membrane of synaptosomes rather than plasma membrane. Based on its structure and properties, p87 appears to define a new class of transporter-like proteins.  相似文献   

11.
Recent developments in chromatography, such as ultra-HPLC and superficially porous particles, offer significantly improved peptide separation. The narrow peak widths, often only several seconds, can permit a 15-min liquid chromatography run to have a similar peak capacity as a 60-min run using traditional HPLC approaches. In theory, these larger peak capacities should provide higher protein coverage and/or more protein identifications when incorporated into a proteomic workflow. We initially observed a decrease in protein coverage when implementing these faster chromatographic approaches, due to data-dependent acquisition (DDA) settings that were not properly set to match the narrow peak widths resulting from newly implemented, fast separation techniques. Oversampling of high-intensity peptides lead to low protein-sequence coverage, and tandem mass spectra (MS/MS) from lower-intensity peptides were of poor quality, as automated MS/MS events were occurring late on chromatographic peaks. These observations led us to optimize DDA settings to use these fast separations. Optimized DDA settings were applied to the analysis of Trypanosome brucei peptides, yielding peptide identifications at a rate almost five times faster than previously used methodologies. The described approach significantly improves protein identification workflows that use typical available instrumentation.  相似文献   

12.
We have developed a novel automated system to analyze protein complexes by integrating a surface plasmon resonance (SPR) biosensor with highly sensitive nanoflow liquid chromatography-tandem mass spectrometry (LC-MS/MS). A His-tagged protein, which is also tagged with FLAG and biotinylated sequences, was expressed in mammalian cells. After purification by using the His tag from the cell lysate, the sample protein mixture was applied to an SPR biosensor and the protein complex was captured on the sensor chip. The automated SPR-LC-MS/MS was then performed: (1) two-step on-chip purification of the protein complex by using the FLAG and the biotinylated tags, (2) on-chip protease digestion of the complex, and (3) online nanoflow LC-MS/MS analysis of the resulting peptide fragments for protein identification. All of these processes could be monitored in real-time by the SPR biosensor. We validated the performance of the system using either FK506-binding protein 52 kDa (FKBP52) or ribosomal protein S19 (rpS19) as bait. Thus, the fully automated SPR-LC-MS/MS system appeared to be a powerful tool for functional proteomics studies, particularly for snapshot analysis of functional cellular complexes and machines.  相似文献   

13.
We investigated the parallel production in medium throughput of mouse proteins, using protocols that involved recombinatorial cloning, protein expression screening and batch purification. The methods were scaled up to allow the simultaneous processing of tens or hundreds of protein samples. Scale-up was achieved in two stages. In an initial study, 30 targets were processed manually but with common protocols for all targets. In the second study, these protocols were applied to 96 target proteins that were processed in an automated manner. The success rates at each stage of the study were similar for both the manual and automated approaches. Overall, 15 of the selected 126 target mouse genes (12%) yielded soluble protein products in a bacterial expression system. This success rate compares favourably with other protein screening projects, particularly for eukaryotic proteins, and could be further improved by modifications at the cloning step.  相似文献   

14.
A 100-kDa protein, termed p100, cross-reacts with antisera raised against a synthetic peptide corresponding to the carboxyl-terminal decapeptide of the alpha-subunit of the retinal G protein Gt. p100 is abundantly expressed in liver and, on subcellular fractionation of rat liver homogenates, is distributed between the cytosolic and microsome fractions (Traub, L. M., Evans, W. H., and Sagi-Eisenberg, R. (1990) Biochem. J. 272, 453-458; Udrisar, D., and Rodbell, M. (1990) Proc. Natl. Acad. Sci. U. S. A. 87, 6321-6325). We have now purified p100 to near-homogeneity from rat liver microsomes. The protein was purified approximately 500-fold by ATP extraction followed by a series of four chromatographic steps. Similar to partially purified p100, on two-dimensional electrophoresis, the final preparation contained a major series of five immunoreactive 100-kDa charge isoforms. Partial amino terminus amino acid sequencing of the purified protein revealed that p100 is a previously unidentified protein. Further analysis of the soluble form of p100 showed the protein migrated with an apparent molecular weight of approximately 110,000 on gel filtration, indicating that the soluble protein occurs as a monomeric polypeptide. The soluble form of p100 was also partially purified from rat liver cytosol and amino acid sequencing yielded the same amino-terminal sequence as obtained from the microsome-associated form. The amino-terminal sequence of p100 exhibits significant similarity to the deduced amino-terminal amino acid sequences of both alpha- and gamma-adaptins. Using the amino-terminal sequence from p100, we have raised antipeptide polyclonal antisera. The antisera reacted specifically with the purified 100-kDa protein on immunoblots. With the purified protein and specific antisera now available, it will be possible to explore the physiological role of p100.  相似文献   

15.
Screening of peptide ligands for affinity chromatography usually involves incubation with the target protein in a batch system. In an additional step, peptides with fast binding kinetics have to be selected in respect to satisfactory performance under flow conditions on a support ensuring optimal three-dimensional presentation of the peptide. We have developed a rapid screening system based on peptide synthesis and screening on CIM((R)) disks. The disk size was minimized to fit into microplates usually applied for solid-phase extraction. In combination with a vacuum manifold, semi-automated peptide synthesis and screening for binding to a target protein under simulated chromatography conditions are possible. Various analytical methods can be applied for parallel and automated determination of the quantity, integrity, or activity of the target protein in the flow through or bound to the affinity support. This system also allows parallel screening for suitable chromatographic conditions like running buffer, washing, and elution conditions.  相似文献   

16.
The study of changes in protein levels between samples derived from cells representing different biological conditions is a key to the understanding of cellular function. There are two main methods available that allow both for global scanning for significantly varying proteins and targeted profiling of proteins of interest. One method is based on 2-D gel electrophoresis and image analysis of labelled proteins. The other method is based on LC-MS/MS analysis of either unlabelled peptides or peptides derived from isotopically labelled proteins or peptides. In this study, the non-labelling approach was used involving a new software, DeCyder MS Differential Analysis Software (DeCyder MS) intended for automated detection and relative quantitation of unlabelled peptides in LC-MS/MS data.Total protein extracts of E. coli strains expressing varying levels of dihydrofolate reductase and integron integrase were digested with trypsin and analyzed using a nanoscale liquid chromatography system, Ettan MDLC, online connected to an LTQTM linear ion-trap mass spectrometer fitted with a nanospray interface. Acquired MS data were subjected to DeCyder MS analysis where 2-D representations of the peptide patterns from individual LC-MS/MS analyses were matched and compared.This approach to unlabelled quantitative analysis of the E. coli proteome resulted in relative protein abundances that were in good agreement with results obtained from traditional methods for measuring protein levels.  相似文献   

17.
Biological libraries are important tools in the development of new peptide-based compounds. Here, we describe the use of a soluble peptide library system as a complementary tool in the field of ligand development. Random peptides were expressed in S. cerevisiae as carboxy-terminal extensions of the eukaryotic initiation factor 5a (eIF5a) and secreted into the culture supernatant. Expression and screening of this library were performed in a microwell format. As an example of this versatile approach, we describe the identification of a ligand for the human IgG-Fc fragment. Ligands binding IgG-Fc show great potential in a wide variety of applications including development of therapeutics, streamlining the large-scale purification of antibodies, and applications in diagnostic tests. We demonstrated the utility of this system. After screening only 6160 clones, we identified a ligand with the peptide sequence of TRRRTCSPPTWPRARARSTPSGCSSTGPSANRG. An affinity constant of 3.9 x 10(5) M(-1) was determined by a biosensor method. Handling and maintenance of this library is conceptually simple and highly applicable for automated high-throughput systems.  相似文献   

18.
Garaguso I  Borlak J 《Proteomics》2008,8(13):2583-2595
The analytical performance of MALDI-MS is highly influenced by sample preparation and the choice of matrix. Here we present an improved MALDI-MS sample preparation method for peptide mass mapping and peptide analysis, based on the use of the 2,5-dihydroxybenzoic acid matrix and prestructured sample supports, termed: matrix layer (ML). This sample preparation is easy to use and results in a rapid automated MALDI-MS and MS/MS with high quality spectra acquisition. The between-spot variation was investigated using standard peptides and statistical treatment of data confirmed the improvement gained with the ML method. Furthermore, the sample preparation method proved to be highly sensitive, in the lower-attomole range for peptides, and we improved the performance of MALDI-MS/MS for characterization of phosphopeptides as well. The method is versatile for the routine analysis of in-gel tryptic digests thereby allowing for an improved protein sequence coverage. Furthermore, reliable protein identification can be achieved without the need of desalting sample preparation. We demonstrate the performance and the robustness of our method using commercially available reference proteins and automated MS and MS/MS analyses of in-gel digests from lung tissue lysate proteins separated by 2-DE.  相似文献   

19.
Shadforth I  Crowther D  Bessant C 《Proteomics》2005,5(16):4082-4095
Current proteomics experiments can generate vast quantities of data very quickly, but this has not been matched by data analysis capabilities. Although there have been a number of recent reviews covering various aspects of peptide and protein identification methods using MS, comparisons of which methods are either the most appropriate for, or the most effective at, their proposed tasks are not readily available. As the need for high-throughput, automated peptide and protein identification systems increases, the creators of such pipelines need to be able to choose algorithms that are going to perform well both in terms of accuracy and computational efficiency. This article therefore provides a review of the currently available core algorithms for PMF, database searching using MS/MS, sequence tag searches and de novo sequencing. We also assess the relative performances of a number of these algorithms. As there is limited reporting of such information in the literature, we conclude that there is a need for the adoption of a system of standardised reporting on the performance of new peptide and protein identification algorithms, based upon freely available datasets. We go on to present our initial suggestions for the format and content of these datasets.  相似文献   

20.
The ability of a soluble heparin-binding oligopeptide sequence derived from the von Willebrand factor (vWF) to modulate the adhesion and chemokinetic migration behavior of arterial smooth muscle cells was assessed using a novel glass microsphere centrifugation assay and automated time-lapse fluorescence videomicroscopy, respectively. Treatment of cells grown on fibronectin-coated substrates with the heparin-binding peptide resulted in the disassembly of focal adhesions, as assessed by immunohistochemical staining. These observations were consistent with six-fold decrease in cell--substrate adhesive strength (P<0.001), a biphasic effect on migration speed (P<0.05), as well as a dose-dependent reduction in the percentage of motile cells and the cell dispersion coefficient (mu=S(2)T/2). The specificity of this response to the vWF-derived heparin-binding peptide was supported by the absence of an observed effect in the presence of either a scrambled peptide or a consensus heparin-binding peptide sequence of similar heparin affinity. These data support the notion that competitive interactions between cell surface heparan sulfates with heparin-binding peptide domains located in soluble peptide fragments may modulate chemokinetic cell migration behavior and other adhesion-related processes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号