首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Epidemiologic evidence does not support an association between silicone breast implants and connective tissue or other rheumatic diseases. However, a recent study has suggested that women with ruptured implants may be at increased risk of developing fibromyalgia. An analysis of adverse health outcomes according to breast implant rupture status was conducted in 238 unselected Danish women with cosmetic silicone breast implants. Ninety-two of the women had definite implant rupture, and 146 had intact implants as determined by magnetic resonance imaging. Before undergoing imaging, the women provided blood samples and completed a self-administered questionnaire. Women with ruptured implants overall, and the subgroup with extracapsular ruptures (n = 23), were compared with women with intact implants regarding a number of self-reported diseases and symptoms and the presence of specific autoantibodies, such as antinuclear antibodies, rheumatoid factor, and cardiolipin immunoglobulin G and M antibodies. Overall, there were no differences in the occurrence of self-reported diseases or symptoms or in the presence of autoantibodies between women with intact implants and women with ruptured implants, including extracapsular rupture. The only exception was capsular contracture, which was reported six times more frequently by women with extracapsular ruptures than by women with intact implants (OR, 6.3; 95 percent CI, 1.7 to 23.5). In conclusion, this study of unselected women with silicone breast implants could establish no association between silicone implant rupture and specific diseases or symptoms related to connective tissue disease or other rheumatic conditions, except for an excess of capsular contracture among women with extracapsular rupture.  相似文献   

2.
Background and purposeBreast reconstruction following mastectomy is a relevant element of breast cancer treatment. The purpose of this study was to evaluate the influence of radiotherapy (RT) on local complications in patients with breast cancer that had undergone breast reconstruction with alloplastic material.Materials and methodsRetrospective study of breast cancer patients submitted to mastectomy and breast reconstruction from 2009 to 2013. Clinical and treatment variables were correlated with early and late complications.Results251 patients were included; mean age was 49.7 (25 to 78) years. Reconstruction was immediate in 94% of the patients, with 88% performed with a temporary tissue expander. Postoperative radiotherapy (RT) was delivered to 167 patients (66.5%). Early complications were present in 26.3% of the patients. Irradiated patients presented 5.4% incidence of late complications versus 2.4% for non-irradiated patients (p = 0.327). Diabetes (OR = 3.41 95% CI: 1.23–9.45, p = 0.018) and high body mass index (BMI) (OR = 2.65; 95% CI: 1.60–4.37, p < 0.0001) were the main risk factors. The overall incidence of late complications was 4.4%, with predominance of severe capsular contracture (8/11). Arterial hypertension (OR = 4.78; 95% CI: 1.97–11.63, p = 0.001), BMI (OR = 0.170; 95% CI: 0.048–0.607, p = 0.006) and implant placement (OR = 3.55; 95% CI: 1.26–9.99, p = 0.016) were related to late complications.ConclusionsThe overall rate of complications was low in this population. Radiotherapy delivery translated into a higher but not statistically significant risk of late complications when compared with the non-irradiated patients. Already well-known clinical risk factors for complications after breast reconstruction were identified.  相似文献   

3.
BackgroundA large number of clinical studies have reported that the different materials used in breast implants were a possible cause of the different incidence rates of capsular contracture observed in patients after implantation. However, this theory lacks comprehensive support from evidence-based medicine, and considerable controversy remains.ObjectivesIn this study, a cumulative systematic review examined breast augmentation that used implants with textured or smooth surfaces to analyze the effects of these two types of implants on the occurrence of postoperative capsular contracture.MethodsWe conducted a comprehensive search of literature databases, including PubMed and EMBASE, for clinical reports on the incidence of capsular contracture after the implantation of breast prostheses. We performed a cumulative meta-analysis on the incidence of capsular contracture in order from small to large sample sizes and conducted subgroup analyses according to the prosthetic material used, the implant pocket placement, the incision type and the duration of follow-up. Relative risks (RR) and 95% confidence intervals (CI) were used as the final pooled statistics.ResultsThis meta-analysis included 16 randomized controlled trials (RCTs) and two retrospective studies. The cumulative comparison of textured and smooth breast implants showed statistical significance at 2.13 (95% CI, 1.18-3.86) when the fourth study was entered into the analysis. With the inclusion of more reports, the final results indicated that smooth breast implants were more likely to be associated with capsular contracture, with statistical significance at 3.10 (95% CI, 2.23-4.33). In the subgroup analyses, the subgroups based on implant materials included the silicone implant group and the saline implant group, with significant pooled statistical levels of 4.05 (95% CI, 1.97-8.31) and 3.12 (95% CI, 2.19-4.42), respectively. According to implant pocket placement, a subglandular group and a submuscular group were included in the analyses, and only the subglandular group had a statistically significant pooled result of 3.59 (95% CI, 2.43-5.30). Four subgroups were included in the analyses according to incision type: the inframammary incision group, the periareolar incision group, the transaxillary incision group and the mastectomy incision group. Among these groups, only the pooled results of the inframammary and mastectomy incision groups were statistically significant, at 2.82 (95% CI, 1.30-6.11) and 2.30 (95% CI, 1.17-4.50), respectively. Three follow-up duration subgroups were included in the analyses: the one-year group, the two- to three-year group and the ≥five-year group. These subgroups had statistically significant results of 4.67 (95% CI, 2.35-9.28), 3.42 (95% CI, 2.26-5.16) and 2.71 (95% CI, 1.64-4.49), respectively.ConclusionIn mammaplasty, the use of textured implants reduces the incidence of postoperative capsular contracture. Differences in implant pocket placement and incision type are also likely to affect the incidence of capsular contracture; however, this conclusion awaits further study.  相似文献   

4.
Cunningham BL  Lokeh A  Gutowski KA 《Plastic and reconstructive surgery》2000,105(6):2143-9; discussion 2150-1
Our center undertook an industry-funded, outcomes-based, multicenter, retrospective review to evaluate the safety and efficacy of saline-filled breast implants. Our review was part of a pre-market approval review process mandated by the U.S. Food and Drug Administration. The design of our review was modeled on a Plastic Surgery Educational Foundation outcomes study previously conducted by our center. For this study, several significant changes were made to our previous protocol, including improved patient tracking, stronger biostatistical support, and a mandatory 10-year minimum patient follow-up period. Physician-reported and patient-reported data on 450 patients with 882 saline-filled breast implants placed between January 1, 1980, and June 30, 1986, were obtained. Mean patient follow-up period was 13.0 years. Most implants (93.9 percent) were placed for breast augmentation. Seventy-four percent were placed in a submammary position; 25.6 percent, subpectorally; and 0.2 percent, subcutaneously. The overall complication rate was 20.2 percent. Reoperation for capsular contracture or implant deflation was necessary in 104 of 450 patients (23.1 percent). Deflation occurred in 73 implants (8.3 percent) and was underreported according to the physicians' record review alone. This deflation rate is higher than the 5.5 percent previously reported by our center. However, 26 of these 73 deflations (35.6 percent) occurred in a single cohort of patients at one center using Surgitek saline implants. If this cohort is excluded, the deflation rate drops to 5.8 percent, a figure more consistent with data published in the literature and found in our previous study. Of the 73 deflations, spontaneous deflation was reported for 50 (74.6 percent), and the remainder were iatrogenic. Actuarial survival of the non-Surgitek implants was 98.4 percent to 99.8 percent at 5 years and 96.9 percent to 98.9 percent at 10 years (95 percent confidence interval). Risk factors for implant deflation included the use of Surgitek saline-filled implants (odds ratio = 17.5, p < 0.01), use of Heyer-Schulte and Mentor model 1800 implants (odds ratio = 3.0, p < 0.01), and implant size greater than 450 cc (odds ratio = 1.01, p < 0.02). Risk factors for capsular contracture included submammary implant position (odds ratio = 2.05, p = 0.03) and implant size greater than 450 cc (odds ratio = 1.01, p < 0.01). Overall, satisfaction was high: 93 percent of patients were "satisfied" or "very satisfied" with their implants. As in our earlier study, risk factors for patient dissatisfaction were reconstruction after mastectomy (odds ratio = 7.6, p = 0.011), significant breast firmness (odds ratio = 6.2, p < 0.001), and patient desire for smaller implants (odds ratio = 3.0, p = 0.020). In conclusion, our review provides additional outcomes-based evidence that saline-filled breast implants remain a safe, effective alternative to silicone gel-filled models.  相似文献   

5.
Surgical treatment of breast cancer in previously augmented patients   总被引:8,自引:0,他引:8  
The incidence of breast cancer is increasing each year. Concomitantly, cosmetic breast augmentation has become the second most often performed cosmetic surgical procedure. As the augmented patient population ages, an increasing number of breast cancer cases among previously augmented women can be anticipated. The surgical treatment of these patients is controversial, with several questions remaining unanswered. Is breast conservation therapy feasible in this patient population and can these patients retain their implants? A retrospective review of all breast cancer patients with a history of previous augmentation mammaplasty who were treated at the Revlon/UCLA Breast Center between 1991 and 2001 was performed. During the study period, 58 patients were treated. Thirty patients (52 percent) were treated with a modified radical mastectomy with implant removal. Twenty-eight patients (48 percent) underwent breast conservation therapy, which consisted of lumpectomy, axillary lymph node dissection, and radiotherapy. Twenty-two of the patients who underwent breast conservation therapy initially retained their implants. Eleven of those 22 patients (50 percent) ultimately required completion mastectomies with implant removal because of implant complications (two patients), local recurrences (five patients), or the inability to obtain negative margins (four patients). Nine additional patients experienced complications resulting from their implants, including contracture, erosion, pain, and rupture. The data illustrate that breast conservation therapy with maintenance of the implant is not ideal for the majority of augmented patients. Breast conservation therapy with explantation and mastopexy might be appropriate for rare patients with large volumes of native breast tissue. Mastectomy with immediate reconstruction might be a more suitable choice for these patients.  相似文献   

6.
Insulin-like growth factor binding protein-1 (IGFBP-1) has been implicated in the development of cardiovascular disease, but it is not known whether IGFBP-1 is related to cardiovascular mortality. We examined the relation of circulating IGFBP-1 to death from coronary heart disease, cardiovascular disease, and all causes in a cohort study consisting of 622 men aged 65 - 84 years, at baseline in 1984. Fasting serum IGFBP-1 and other risk factors were measured in 1984 and 1989. Cardiovascular events for those who died between 1984 and 1995 were analyzed, and cardiovascular diagnoses were coded centrally according to standardized procedures. Of the 622 men, 358 died between 1984 and 1995; 160 deaths were due to cardiovascular causes, 113 of which were coronary deaths. High fasting serum IGFBP-1 concentration (> 75 percentile) in 1984 was associated with increased five-year total mortality (OR 2.05, 95 % CI 1.41 - 2.99; p < 0.0002), cardiovascular mortality (OR 2.20, 95 % CI 1.37 - 3.50; p < 0.0009) and coronary heart disease mortality (OR 2.29, 95 % CI 1.35 - 3.88; p < 0.002). After adjustment for age, high serum IGFBP-1 concentrations still carried an increased risk of total mortality due to (OR 1.73, 95 % CI 1.16 - 2.59; p < 0.007), cardiovascular (OR 1.91 95 % CI 1.18 - 3.09; p < 0.008) and coronary heart disease (OR 2.02. 95 % CI 1.18 - 3.47; p < 0.01). In conclusion, high fasting serum IGFBP-1 is related to increased five-year total and cardiovascular mortality in elderly men.  相似文献   

7.
The long-term cosmetic outcome of breast implant reconstruction is unknown. The morbidity and cosmetic outcome of 360 patients who underwent immediate postmastectomy breast reconstruction with various types of implants have been analyzed prospectively over a 9-year period. Of these patients, 334 who completed their reconstruction were suitable for evaluation of their cosmetic outcome. The early complication rate (< 2 months) was 9.2 percent, with an explantation rate of 1.7 percent. The late complication rate (> 2 months) was 23 percent, with a pathological capsular contracture rate of 11 percent at 2 years and 15 percent at 5 years and an implant removal rate of 7 percent. The revisional surgery rate was 30.2 percent.The cosmetic results were assessed prospectively using an objective five-point global scale. Every patient was scored at each visit once surgery was completed. The overall cosmetic outcome deteriorated in a linear fashion, from an initial acceptable result of 86 percent 2 years after patients completed their reconstruction to only 54 percent at 5 years. This decline in cosmetic outcome was not associated with the type of implant used, the volume of the implant, the age of the patient, or the type of mastectomy incision employed. Radiotherapy was not a significant factor because only 28 patients were irradiated. Upon Cox model analysis, pathological capsular contracture was the only factor that contributed significantly to a poor cosmetic outcome in which p < 0.0001 (relative risk 6.3). Despite a high revisional surgery rate, deterioration still occurred, suggesting that other unaccounted for variables were responsible. On photographic retrospective review of the patients without capsular contracture who demonstrated deterioration in their cosmetic scores, it became clear that a possible reason for their poor results was late asymmetry produced by the failure of both breasts to undergo symmetrical ptosis with aging.  相似文献   

8.
Collis N  Sharpe DT 《Plastic and reconstructive surgery》2000,105(6):1979-85; discussion 1986-9
Concern has been expressed over the long-term integrity of silicone gel breast implants. There are no large series representing experience with these implants outside of the United States. A retrospective case note review of explanted silicone breast implants was performed; 478 implants have been explanted during the past 11 years and relate to the use of these devices since 1971. Loss of implant integrity was not simply related to its age in vivo. Failure was more likely with implants of the late 1970s and early 1980s (second generation) and with subpectoral placement. Implant failure was independent of capsular contracture as the indication for removal (p = 0.09). There is no evidence that the currently used textured silicone gel breast implants are subject to the same loss of integrity as previous examples of these devices. The life span of these implants, the first of which are approaching 10 years in vivo, is at present unknown. Information concerning the integrity of silicone gel breast implants is essential in the current climate for counseling of both new and old implant recipients.  相似文献   

9.
Subfascial breast implant: a new procedure   总被引:18,自引:0,他引:18  
Breast augmentation techniques using the submuscular and subglandular planes to introduce the implant are well known and widely used procedures. The authors have been using the subfascial dissection plane, a new concept for breast augmentation. From October of 1998 to September of 2001, 263 patients underwent breast augmentation. In all cases, the implants were inserted into the subfascial plane. McGhan 410 anatomic biodimensional, cohesive gel implants (size, 155 to 310 g) were used. There are additional benefits using this technique; these include avoiding implant deformation or distortion (as seen in the retromuscular position), leaving additional soft tissue between the implant and the skin, and minimizing implant edge prominence (inherent to retroglandular placement). These technical details lead to fewer patient complaints. Morbidity is similar to that of other techniques.  相似文献   

10.
MISTI Gold breast implants (Bioplasty, St. Paul, Minn.) filled with polyvinylpyrrolidone-hydrogel were developed as a promising alternative to silicone-filled implants. Some studies have reported on the positive effects of the implant, such as improved radiolucency and biocompatibility of the gel; however, there are also reports that such implants increased in volume and were subject to capsular contracture in the human body, resulting in demands for their removal. The purpose of this retrospective study was to analyze the long-term results of a series of patients with MISTI Gold breast implants. Between 1991 and 1993, the authors inserted 83 MISTI Gold implants in 61 patients with an average age of 46 years (range, 16 to 69). The authors were able to follow up 48 patients with 71 MISTI Gold implants. The average follow-up was 68 months (range, 10 to 108 months). The retrospective study found that 59 percent of all MISTI Gold implants were removed after an average period of 4.14 years. The main reason for implant removal was an increase in volume of 38 percent, followed by capsular contracture in 14 percent of all 71 MISTI Gold implants. The average increase in volume of all removed MISTI Gold implants was 43 percent. Capsular contracture was graded as Baker I and II in 63 percent and as Baker III and IV in 37 percent. In conclusion, the authors believe that MISTI Gold implants do not fulfill the criteria of safe breast implants, and they agree with the December of 2000 opinion of the Medical Devices Agency of the Department of Health in London that the hydrogel-filled breast implants should not be used until more information about the filler material and its metabolic fate is available.  相似文献   

11.
The durability of silicone gel-filled breast implants is of concern, but there are few epidemiological studies on this issue. To date, most of the relevant findings are derived from studies of explantation, which suffer from bias by including women with symptoms or concerns about their implants. As part of a long-term magnetic resonance imaging study of the incidence of rupture, this study involved 271 women with 533 cosmetic breast implants who were randomly selected from among women who underwent cosmetic breast implantation from 1973 through 1997 at one public and three private plastic-surgery clinics in Denmark. The prevalence of rupture was determined from the first magnetic resonance screening. The images were evaluated by four independent readers, using a standardized, validated form. The outcomes under study were rupture, possible rupture, and intact implant. Ruptures were categorized as intracapsular or extracapsular. Overall, 26 percent of implants in 36 percent of the women examined were found to be ruptured, and an additional 6 percent were possibly ruptured. Of the ruptured implants, 22 percent were extracapsular. In multiple regression analyses, age of implant was significantly associated with rupture among second- and third-generation implants, with a 12-fold increased prevalence odds ratio for rupture of implants that were between 16 and 20 years of age, compared with implants between 3 and 5 years of age. Surgitek implants (Medical Engineering Corporation, Racine, Wis.) had a significantly increased prevalence odds ratio of 2.6 for rupture, compared with the reference implants. No significant association was found with the position (subglandular or submuscular) or the type of implant (single- or double-lumen). Extracapsular ruptures were significantly associated with a history of closed capsulotomy (p = 0.001). In the future, the authors plan to examine the women in their cohort with a second magnetic resonance imaging scan to establish the incidence of rupture, a parameter unknown to date in the literature, and to further characterize those factors associated with the actual risk of rupture.  相似文献   

12.
Hidalgo DA 《Plastic and reconstructive surgery》2000,105(6):2202-16; discussion 2217-8
A retrospective study of 220 patients was performed to review surgical design in breast augmentation. Three specific issues were studied: incision site, implant variables, and pocket plane selection. The influence of these three factors on aesthetic results in both primary and secondary cases was the focus of the analysis. No attempt was made to address long-term issues such as capsular contracture or saline implant deflation rates. In 77 primary augmentation patients and 80 unilateral augmentations for symmetry in breast reconstruction, there were the following untoward results: 11 revisions for unilateral malposition, change to a different implant shape, or change to a larger implant size; four deflations of saline implants requiring replacement; and four conversions of saline to silicone gel implants. In 63 secondary cases, there were two hematomas and two infections requiring implant removal and subsequent replacement. Operative technique in breast augmentation is described, as are recommendations for each of the options associated with the three variables studied.  相似文献   

13.
Hu Y  Jiang L  Zheng J  You Y  Zhou Y  Jiao S 《DNA and cell biology》2012,31(2):230-237
The TP53 homolog p73 is structurally and functionally similar to TP53 and plays an important role in modulating cell-cycle control, apoptosis, and cell growth. G4C14-to-A4T14 is the most commonly studied polymorphism of this gene for its association with risk of cancers, but the results are confusing rather than conclusive. We performed a meta-analysis using 21 eligible studies with a total of 7581 patients and 10,413 controls to summarize the data for an association between the p73 G4C14-to-A4T14 polymorphism and cancer risk. Compared with the common GC/GC genotype, the AT carriers (AT/GC, AT/AT) had a 1.18-fold elevated risk of cancer (95% confidence interval [CI]=1.11-1.25, p<0.00001) in a dominant genetic model as estimated in a fixed effect model. The effect of the G4C14-to-A4T14 polymorphism was further evaluated through stratification analysis. In four lung cancer studies, the variant genotypes had a significantly increased risk of lung cancer (odds ratio [OR]=1.16, 95% CI=1.04-1.28, p=0.005). Similar phenomena were also found in two squamous cell carcinoma of the head and neck studies (OR=1.32, 95% CI=1.12-1.56, p=0.0010), two oral cancer studies (OR=1.57, 95% CI=1.26-1.95, p<0.0001), and three colorectal cancer studies (OR=1.23, 95% CI=1.01-1.50, p=0.04). Increased risk of cancer associated with G4C14-to-A4T14 variant genotypes was pronounced in Caucasians (OR=1.21, 95% CI=1.11-1.31, p<0.00001), the Japanese population (OR=1.24, 95% CI=1.01-1.52, p=0.04), and the Korean population (OR=1.27, 95% CI=1.07-1.52, p=0.007). Our meta-analysis suggests that the p73 G4C14-to-A4T14 polymorphism genotypes (GC/AT+AT/AT) may be associated with an increased risk of cancer in most cancer types and ethnicities.  相似文献   

14.
In June of 2000, the U.K. Medical Device Agency recommended the removal of Trilucent implants as a precautionary maneuver in response to reports of local inflammatory reactions. This decision allowed the authors to operate on 115 consecutive patients between June of 2000 and January of 2001. On the preoperative examination, the authors found a very high incidence of rippling (66 percent), whereas capsular contracture was seen in only three patients (2.6 percent). Rippling was significantly more common in patients with subglandular implants. Five implants were found ruptured during the operation. This figure, together with the relative ease of implant breakage at removal, shows a premature deterioration of the implant shell. The authors also comment on implant bleeding, which seems common in this type of breast implant. The authors think that this is a possible cause for the rippling phenomenon, resulting from a reduction of the implant content. On the basis of these findings, the authors conclude that Trilucent implants are associated with a poor cosmetic outcome and a high rate of complications.  相似文献   

15.
At the time of immediate breast reconstruction with submuscular implants, 76 consecutive patients (89 breasts) were randomized into two groups. One received a gel-saline, double-lumen implant with 40 cc of saline added to the outer lumen, while the other received the same implant plus 40 cc of saline and 16 mg methyl prednisolone (40 mg%). Patients were followed for a minimum of 3 years. The groups, which were matched for patient age and implant size, were evaluated at 3, 12, 24, and 36 months for capsular contracture, steroid atrophy, and other complications. With completion of the double-blind study, the patients with submuscular gel-saline implants with only saline added had an overall capsular contracture rate of 38 percent at 3 months, 38 percent at 12 months, and 44 percent at 24 and 36 months. Those with methyl prednisolone had an overall capsular contracture rate of 14 percent at 3 months, and this remained unchanged through the end of the study. The rates of all other complications were comparable. Methyl prednisolone in a dose of 16 mg in 40 cc saline (concentration 40 mg%), when used in the outer lumen of a double-lumen gel-saline implant in a submuscular pocket, is both safe and efficacious in reducing the risk of capsular contracture for a minimum of 3 years in patients undergoing immediate breast reconstruction with submuscular mammary implants.  相似文献   

16.
Comparisons between results with randomly allotted silicone-gel and saline-filled prostheses in breast reconstruction after mastectomy led to the following conclusions. Neither prosthesis type is ideal. Leakage from saline-filled implants occurred in 2 of the 37 implants, with resultant deflation. Silicone prostheses had a significantly higher rate of capsular contracture [surgeon's evaluation: 54 percent capsular contracture for silicone-gel compared with 20 percent for saline-filled prostheses (p = 0.006); patients' evaluation for the same figures: 54 percent compared with 29 percent (p = 0.03)]. Other authors have shown the presence of silicone in the tissue around silicone-gel-filled silicone implants, but less or none around saline-filled silicone implants. Since the only difference between the two groups was the randomly allotted implants, we assume that the free silicone around silicone-gel-filled prostheses is the major cause of capsular contracture. Since the saline-filled implants showed a 20 percent capsular contracture rate, there could be other causes of capsular contracture in this study. For prevention of contracture, improved implant encapsulation and use of a less reactive filling substance seem to offer possibilities. Surgical technique should aim to preserve the integrity of the prosthesis.  相似文献   

17.
D Fagrell  A Berggren  E Tarpila 《Plastic and reconstructive surgery》2001,108(7):2108-12; discussion 2113
In a previous prospective randomized clinical study comparing in the same patient textured and smooth saline-filled mammary implants (Biocell) with large pore size (300 to 600 microm), we saw no difference in capsular contracture. This study was undertaken in a similar way to compare capsular contracture around smooth and textured saline-filled prostheses with pores of small size. During a period of 7.5 years, the breast hardness was followed up, and at the end of the study patient satisfaction was evaluated.Twenty healthy women with a mean age of 30 years were operated on for breast augmentation. Two surgeons performed all operations in a standardized way. Each patient received subglandularly a Siltex textured saline-filled prosthesis with a pore size of 30 to 70 microm in one breast, and a smooth saline-filled prosthesis in the other. The hardness of the breasts was evaluated after 0.5, 1, and 7.5 years using Baker grading and applanation tonometry. Eighteen patients completed 1-year and 7.5-year follow-up. Two breasts with smooth prostheses were contracted after 6 months (Baker III or IV). After 1 year, four patients with smooth prostheses and one with a textured prosthesis had capsular contracture (p = 0.34). Seven and one-half years after surgery, six patents with smooth and four with textured implants had contracture (p = 0.66). On two patients with smooth prostheses and one patient with a textured prosthesis, the capsule around the implant hardened between 6 and 12 months. Between 1 year and 7.5 years, three breasts with smooth and textured implants contracted and one with a textured implant softened.The patients reported on a Visual Analogue Scale (1 to 10) the impact of the augmentation on their quality of life to be 9 +/- 1. Four patients preferred the breast with the smooth prosthesis, three preferred the breast with the textured prosthesis, and the others found both breasts equal. This study showed no significant difference of contracture with smooth versus fine textured implants. The majority of the patients preferred the smooth implants. The patients reported that the breast augmentation had had an extremely high impact on their quality of life.  相似文献   

18.
Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untreated ruptures are associated with changes over time in magnetic resonance imaging findings, serologic markers, or self-reported breast symptoms. A baseline magnetic resonance imaging examination was performed in 1999 on 271 women who were randomly chosen from a larger cohort of women having cosmetic breast implants for a median period of 12 years (range, 3 to 25 years). A follow-up magnetic resonance imaging examination was carried out in 2001, excluding women who underwent explantation in the period between the two magnetic resonance imaging examinations (n = 44). On the basis of these examinations, the authors identified 64 women who had at least one ruptured implant at the first magnetic resonance imaging examination and, for comparison, all women who had intact implants at both examinations (n = 98). Magnetic resonance images from the two examinations were compared and changes in rupture configuration were evaluated. Comparisons were also made for self-reported breast symptoms occurring during the study period and for changes in serum values of antinuclear antibodies, rheumatoid factor, and cardiolipin antibodies immunoglobulin G and immunoglobulin M. The majority of the women with implant rupture had no visible magnetic resonance imaging changes of their ruptured implants. For 11 implants (11 percent) in 10 women, the authors observed progression of silicone seepage, either as a conversion from intracapsular into extracapsular rupture (n = 7), as progression of extra-capsular silicone (n = 3), or as increasing herniation of the silicone within the fibrous capsule (n = 1); however, in most cases, these changes were minor. Some changes could be ascribed to trauma, but others seemed spontaneous. There was no increase in levels of autoantibodies during the study period in either study group. Women with untreated implant ruptures reported a significant increase in nonspecific breast changes (odds ratio, 2.1; 95 percent confidence interval, 1.2 to 3.8) compared with women without ruptures. On the basis of this first study of women with untreated silicone breast implant rupture, the authors conclude that implant rupture is a relatively harmless condition, which only rarely progresses and gives rise to notable symptoms. Even so, because of a small risk of silicone spread, the authors suggest that women with implant ruptures be followed clinically, if not operated on. Because implant ruptures often occur asymptomatically, any woman with silicone implants, regardless of rupture status, should be evaluated at regular intervals.  相似文献   

19.
BACKGROUND: Maternal epidemiologic similarities between gastroschisis and preeclampsia have led to the objective of evaluating the risk for gastroschisis related to primigravidity, change in paternity, and length of cohabitation, considered as risk factors for preeclampsia. METHODS: The subjects were 288 newborns with isolated gastroschisis and 576 normal controls, matched by maternal age. They were ascertained in the Estudio Colaborativo Latino Americano de Malformaciones Congenitas hospital network of 10 South American countries between 1982 and 2005. Epidemiologic variables were compared among controls, between primigravidas and multigravidas, between multigravidas who had and had not changed partners, and between mothers with short and long cohabitation times with their partners. Risks associated with primigravidity, short cohabitation time, and changing paternity, as well as their combinations, were calculated. An eventual interaction between maternal age and the three risk factors was assessed. RESULTS: Only a short cohabitation time showed a significant OR for gastroschisis (OR = 2.36, 95% CI: 1.52-3.66, p < .001), whereas ORs were not significant for primigravidity (OR = 1.40, 95% CI: 0.84-2.35, p = .192) nor for changing paternity (OR = 1.20, 95% CI: 0.49-3.10, p = .752). The risk was highest for multigravidas who had changed partners (OR = 8.71, 95% CI: 2.93-21.12, p < .001), followed by multigravidas who had not changed partners (OR = 3.99, 95% CI: 1.07-15.43, p = .049), and by primigravidas (OR = 3.02, 95% CI: 1.58-5.76, p = .001), all having cohabitated for a short time. Maternal age did not modify these risks. CONCLUSIONS: Three groups at risk for a child with gastroschisis were identified, all having in common a short cohabitation time. Antigenic or "modern" lifestyle-related factors might be involved in the origin of gastroschisis.  相似文献   

20.
Long-term use of polyurethane breast prostheses: a 14-year experience   总被引:1,自引:0,他引:1  
I have used polyurethane prostheses for the past 14 years, implanting 220 implants into 130 patients who desired breast reconstruction after subcutaneous mastectomy or cancer ablation or simply breast augmentation. I theorize that a polyurethane-covered implant resists contracture, retaining its compressibility because the fibroblasts proliferate into the polyurethane in many different directions. When the fibrils contract, the forces of contracture counterbalance one another, resisting contracture. However, when smooth prostheses are implanted, fibrils are directed in a circular fashion around the implant and naturally contract, leading to firmer breasts. There were 115 prostheses inserted following subcutaneous mastectomy, and 22 percent developed contracted capsules. Seven implants became exposed because of skin necroses; one was removed because of a Staphylococcus infection; and two patients developed a combination of polyurethane and silicone granulomas. These developed only with the earlier implant, where there was shedding of the polyurethane sponge layer and silicone bled from the low-viscosity silicone used in the earlier implants. No granulomas were noted with the currently used Surgitek Replicon implant. Eighty-five breasts were reconstructed after cancer ablation with polyurethane implants, and the contracture rate was 2.3 percent. Other complications were minimal. A smaller group of patients had augmentation mammaplasty, and 20 prostheses were placed in 10 patients. A 15 percent contracture rate was noted in this group. In this study, 82 percent of patients were followed for up to 14 years. Capsular contractures occurred in 30 implants between 1 and 11 years, for an average recurrence at 6.3 years. The overall contracture rate was 13 percent. Other complications were minimal. All implants were placed subcutaneously or subglandularly, and all were drained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号