首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
Studies of the load transfer role of the meniscus have been limited to static experimental and analytical approaches. The objective of this study was to develop an experimental technique to allow the contact pressures on the tibial plateau of cadaveric knees to be measured under dynamic physiological loads. Accordingly, we adapted a load-controlled knee joint simulator to accept a cadaveric sheep knee, programmed the simulator with sheep gait kinematics data, and utilized a pressure sensor array to measure the contact pressure distribution on the lateral tibial plateau during gait. The technique was applied to six sheep knees that were tested intact and after meniscectomy. Meniscectomy resulted in a 267% increase in average contact pressure, a 117% increase in peak contact pressure, and an 80% decrease in contact area, all measured at the point of maximum peak contact stress in the gait cycle. It is envisaged that the experimental model herein developed will allow for the screening of candidate materials prior to more expensive and time-consuming animal models.  相似文献   

2.
Malalignment is the main cause of tibial component loosening. Implants that migrate rapidly in the first two post-operative years are likely to present aseptic loosening. It has been suggested that cancellous bone stresses can be correlated with tibial component migration. A recent study has shown that patient-specific finite element (FE) models have the power to predict the short-term behavior of tibial trays. The stresses generated within the implanted tibia are dependent on the kinematics of the joint; however, previous studies have ignored the kinematics and only applied static loads. Using explicit FE, it is possible to simultaneously predict the kinematics and stresses during a gait cycle. The aim of this study was to examine the cancellous bone strains during the stance phase of the gait cycle, for varying degrees of varus/valgus eccentric loading using explicit FE. A patient-specific model of a proximal tibia was created from CT scan images, including heterogeneous bone properties. The proximal tibia was implanted with a commercial total knee replacement (TKR) model. The stance phase of gait was simulated and the applied loads and boundary conditions were based on those used for the Stanmore knee simulator. Eccentric loading was simulated. As well as examining the tibial bone strains (minimum and maximum principal strain), the kinematics of the bone-implant construct are also reported. The maximum anterior-posterior displacements and internal-external rotations were produced by the model with 20 mm offset. The peak minimum and maximum principal strain values increased as the load was shifted laterally, reaching a maximum magnitude for -20 mm offset. This suggests that when in varus, the load transferred to the bone is shifted medially, and as the bone supporting this load is stiffer, the resulting peak bone strains are lower than when the load is shifted laterally (valgus). For this particular patient, the TKR design analyzed produced the highest cancellous bone strains when in valgus. This study has provided an insight in the variations produced in bone strain distribution when the axial load is applied eccentrically. To the authors' knowledge, this is the first time that the bone strain distribution of a proximal implanted tibia has been examined, also accounting for the kinematics of the tibio-femoral joint as part of the simulation. This approach gives greater insight into the overall performance of TKR.  相似文献   

3.
The purpose of this investigation was to study the kinematics and kinetics of the joints between the leg and calcaneus during the stance phase of walking. The talocrural and talocalcaneal joints were each assumed to act as monocentric single degree of freedom hinge joints. Motion at one joint was defined by the relative rotation of a point on the opposing joint. The results, based upon the gait of three subjects, showed that the hinge joint assumption may be reasonable. A discrepancy in the kinematics was shown between the talocrural joint rotation and its commonly assumed sagittal plane representation, especially during initial flatfoot. This discrepancy is due to the fact that the sagittal plane rotation is created by the combined rotations of the talocrural and talocalcaneal joints. The talocalcaneal joint showed a peak 25-30 Nm supinatory moment at 80% of stance. The talocrural joint moment was qualitatively similar to the commonly measured sagittal plane moment, but the present results show that the sagittal plane moment overpredicted the true moment by 6-22% due to the two-dimensional assumption.  相似文献   

4.
Obtaining accurate values of joint tissue loads in human subjects and animals in vivo requires exact 3D-reproduction of joint kinematics and comparisons of in vivo motions between subjects and animals, and also necessitates an accurate reference position. For the knee, passive flexion-extension of isolated joints by hand has been assumed to produce bony motions similar to those of normal gait. We hypothesized that passive flexion-extension kinematics would not accurately reproduce in vivo gait, and, further, that such kinematics would vary significantly between testers. In vivo gait motions of four ovine stifle joints were measured in six degrees of freedom, as were passive flexion-extension motions after sacrifice. Passive flexion-extension motions were performed by three testers on the same stifle joints used in vitro. Results showed statistically significant differences in all degrees of freedom, with the largest differences in the proximal-distal and internal-external directions. Differences induced by muscle loads and kinetic factors in vivo were most evident during stance and hoof-off phases of gait. The in vitro passive paths generated by hand created motions with large variability both between and within individual testers. The user dependence and "area" of motion of passive flexion-extension indicates that passive flexion-extension is contained in a volume of motion, rather than constrained to a unique path. The assumption that the passive path has relevance to precise bone positions during normal in vivo gait is not supported by these results. Thus, using passive flexion-extension as a reference between joints may introduce large motion variability in the observed outcome, and large potential errors in determining joint tissue loads.  相似文献   

5.
Relatively high rates of loosening and implant failure have been reported after total ankle arthroplasty. Abnormal kinematics and incongruency of the articular surface may cause increased contact pressure and rotational torque applied to the implant, leading to loosening and implant failure. We measured in vivo kinematics of two-component total ankle arthroplasty (TNK ankle), and assessed congruency of the articular surface during the stance phase of gait. Eighteen ankles of 15 patients with a mean age of 75±6 years (mean±standard deviation) and follow-up of 44±38 months were enrolled. Lateral fluoroscopic images were taken during the stance phase of gait. 3D-2D model-image registration was performed using the fluoroscopic image and the implant models, and three-dimensional kinematics of the implant and incongruency of the articular surface were determined. The mean ranges of motion were 11.1±4.6°, 0.8±0.4°, and 2.6±1.5° for dorsi-/plantarflexion, inversion/eversion, and internal/external rotation, respectively. At least one type of incongruency of the articular surface occurred in eight of 18 ankles, including anterior hinging in one ankle, medial or lateral lift off in four ankles, and excessive axial rotation in five ankles. Among the four ankles in which lift off occurred during gait, only one ankle showed lift off in the static weightbearing radiograph. Our observations will provide useful data against which kinematics of other implant designs, such as three-component total ankle arthroplasty, can be compared. Our results also showed that evaluation of lift off in the standard weightbearing radiograph may not predict its occurrence during gait.  相似文献   

6.
Treadmill has been broadly used in laboratory and rehabilitation settings for the purpose of facilitating human locomotion analysis and gait training. The objective of this study was to determine whether dynamic gait stability differs or resembles between the two walking conditions (overground vs. treadmill) among young adults. Fifty-four healthy young adults (age: 23.9 ± 4.7 years) participated in this study. Each participant completed five trials of overground walking followed by five trials of treadmill walking at a self-selected speed while their full body kinematics were gathered by a motion capture system. The spatiotemporal gait parameters and dynamic gait stability were compared between the two walking conditions. The results revealed that participants adopted a “cautious gait” on the treadmill compared with over ground in response to the possible inherent challenges to balance imposed by treadmill walking. The cautious gait, which was achieved by walking slower with a shorter step length, less backward leaning trunk, shortened single stance phase, prolonged double stance phase, and more flatfoot landing, ensures the comparable dynamic stability between the two walking conditions. This study could provide insightful information about dynamic gait stability control during treadmill ambulation in young adults.  相似文献   

7.
This study determined in-vitro anterior cruciate ligament (ACL) force patterns and investigated the effect of external tibial loads on the ACL force patterns during simulated weight-bearing knee flexions. Nine human cadaveric knee specimens were mounted on a dynamic knee simulator, and weight-bearing knee flexions with a 100N of ground reaction force were simulated; while a robotic/universal force sensor (UFS) system was used to provide external tibial loads during the movement. Three external tibial loading conditions were simulated, including no external tibial load (termed BW only), a 50N anterior tibial force (ATF), and a 5Nm internal rotation tibial torque (ITT). The tibial and femoral kinematics was measured with an ultrasonic motion capture system. These movement paths were then accurately reproduced on a robotic testing system, and the in-situ force in the ACL was determined via the principle of superposition. The results showed that the ATF significantly increased the in-situ ACL force by up to 60% during 0-55 degrees of flexion, while the ITT did not. The magnitude of ACL forces decreased with increasing flexion angle for all loading conditions. The tibial anterior translation was not affected by the application of ATF, whereas the tibial internal rotation was significantly increased by the application of ITT. These data indicate that, in a weight-bearing knee flexion, ACL provides substantial resistance to the externally applied ATF but not to the ITT.  相似文献   

8.
The spatial distribution and pattern of local contact stresses within the knee joint during activities of daily living have not been fully investigated. The objective of this study was to determine if common contact stress patterns exist on the tibial plateaus of human knees during simulated gait. To test this hypothesis, we developed a novel normalized cross-correlation (NCC) algorithm and applied it to the contact stresses on the tibial plateaus of 12 human cadaveric knees subjected to multi-directional loads mimicking gait. The contact stress profiles at different locations on the tibial plateaus were compared, where regions with similar contact stress patterns were identified across specimens. Three consistent regional patterns were found, among them two most prominent contact stress patterns were shared by 9–12 of all the knees and the third pattern was shared by 6–8 knees. The first pattern was located at the posterior aspect of the medial tibial plateau and had a single peak stress that occurred during the early stance phase. The second pattern was located at the central-posterior aspects of the lateral plateau and consisted of two peak stresses coincident with the timing of peak axial force at early and late stance. The third pattern was found on the anterior aspect of cartilage-to-cartilage contact region on the medial plateau consisted of double peak stresses. The differences in the location and profile of the contact stress patterns suggest that the medial and lateral menisci function to carry load at different points in the gait cycle: with the posterior aspect of the medial meniscus consistently distributing load only during the early phase of stance, and the posterior aspect of the lateral meniscus consistently distributing load during both the early and late phases of stance. This novel approach can help identify abnormalities in knee contact mechanics and provide a better understanding of the mechanical pathways leading to post-traumatic osteoarthritis.  相似文献   

9.
Pre-clinical experimental wear testing of total knee replacement (TKR) components is an invaluable tool for evaluating new implant designs and materials. However, wear testing can be a lengthy and expensive process, and hence parametric studies evaluating the effects of geometric, loading, or alignment perturbations may at times be cost-prohibitive. The objectives of this study were to develop an adaptive FE method capable of simulating wear of a polyethylene tibial insert and to compare predicted kinematics, weight loss due to wear, and wear depth contours to results from a force-controlled experimental knee simulator. Finite element-based computational wear predictions were performed to 5 million gait cycles using both force- and displacement-controlled inputs. The displacement-controlled inputs, by accurately matching the experimental tibiofemoral motion, provided an evaluation of the simple wear theory. The force-controlled inputs provided an evaluation of the overall numerical method by simultaneously predicting both kinematics and wear. Analysis of the predicted wear convergence behavior indicated that 10 iterations, each representing 500,000 gait cycles, were required to achieve numerical accuracy. Using a wear factor estimated from the literature, the predicted kinematics, polyethylene wear contours, and weight loss were in reasonable agreement with the experimental data, particularly for the stance phase of gait. Although further development of the simplified wear theory is important, the initial predictions are encouraging for future use in design phase implant evaluation. In contrast to the experimental testing which occurred over approximately 2 months, computational wear predictions required only 2h.  相似文献   

10.
Quantifying the mechanical environment at the knee is crucial for developing successful rehabilitation and surgical protocols. Computational models have been developed to complement in vitro studies, but are typically created to represent healthy conditions, and may not be useful in modeling pathology and repair. Thus, the objective of this study was to create finite element (FE) models of the natural knee, including specimen-specific tibiofemoral (TF) and patellofemoral (PF) soft tissue structures, and to evaluate joint mechanics in intact and ACL-deficient conditions. Simulated gait in a whole joint knee simulator was performed on two cadaveric specimens in an intact state and subsequently repeated following ACL resection. Simulated gait was performed using motor-actuated quadriceps, and loads at the hip and ankle. Specimen-specific FE models of these experiments were developed in both intact and ACL-deficient states. Model simulations compared kinematics and loading of the experimental TF and PF joints, with average RMS differences [max] of 3.0° [8.2°] and 2.1° [8.4°] in rotations, and 1.7 [3.0] and 2.5 [5.1] mm in translations, for intact and ACL-deficient states, respectively. The timing of peak quadriceps force during stance and swing phase of gait was accurately replicated within 2° of knee flexion and with an average error of 16.7% across specimens and pathology. Ligament recruitment patterns were unique in each specimen; recruitment variability was likely influenced by variations in ligament attachment locations. ACL resections demonstrated contrasting joint mechanics in the two specimens with altered knee motion shown in one specimen (up to 5 mm anterior tibial translation) while increased TF joint loading was shown in the other (up to 400 N).  相似文献   

11.
The presence of multiple foot types has been used to explain the variability of foot structure observed among healthy adults. These foot types were determined by specific static morphologic features and included rectus (well aligned hindfoot/forefoot), planus (low arched), and cavus (high arched) foot types. Unique biomechanical characteristics of these foot types have been identified but reported differences in segmental foot kinematics among them has been inconsistent due to differences in neutral referencing and evaluation of only select discrete variables. This study used the radiographically-indexed Milwaukee Foot Model to evaluate differences in segmental foot kinematics among healthy adults with rectus, planus, and cavus feet based on the true bony alignment between segments. Based on the definitions of the individual foot types and due to conflicting results in previous literature, the primary study outcome was peak coronal hindfoot position during stance phase. Additionally, locally weighted regression smoothing with alpha-adjusted serial t-test analysis (LAAST) was used to compare these foot types across the entire gait cycle. Average peak hindfoot inversion was −1.6° ± 5.1°, 6.7° ± 3.5°, and 13.6° ± 4.6°, for the Planus, Rectus, and Cavus Groups, respectively. There were significant differences among all comparisons. Differences were observed between the Rectus and Planus Groups and Cavus and Planus Groups throughout the gait cycle. Additionally, the Planus Group had a premature peak velocity toward coronal varus and early transition toward valgus, likely due to a deficient windlass mechanism. This assessment of kinematic data across the gait cycle can help understand differences in dynamic foot function among foot types.  相似文献   

12.
Total ankle replacement (TAR) designs have still several important issues to be addressed before the treatment becomes fully acceptable clinically. Very little is known about the performance, in terms of the contact pressures and kinematics of TAR when subjected to daily activities such as level gait. For this purpose, an explicit finite element model of a novel 3-component TAR was developed, which incorporated a previously validated mechanical model of the ankle ligament apparatus. The intermediate mobile polyethylene meniscal bearing was modelled as an elastic-plastic continuum while the articulating surfaces of the tibial and talar metal components as rigid bodies. Overall kinematics, contact pressures and ligament forces were analysed during passive, i.e. virtually unloaded, and active, i.e. stance phase of gait, conditions. Simulation of passive motion predicted similar kinematics as reported previously in an analytical four-bar linkage model. The meniscal bearing was observed to move 5.6 mm posteriorly during the simulated stance and the corresponding antero-posterior displacement of the talar component was 8.3 mm. The predicted pattern and the amount (10.6 degrees ) of internal-external rotation of the ankle complex were found to be in good agreement with corresponding in vivo measurements on normal ankles. A peak contact pressure of 16.8 MPa was observed, with majority of contact pressures below 10 MPa. For most ligaments, reaction forces remain within corresponding physiological ranges. A first realistic representation of the biomechanical behaviour of the human ankle when replaced by prosthetic joints is provided. The applied methodology can potentially be applied to other TAR designs.  相似文献   

13.
Development of a robotic walking simulator for gait rehabilitation]   总被引:1,自引:0,他引:1  
Restoration of gait is a major concern of rehabilitation after stroke or spinal cord injury. Modern concepts of motor learning favour a task-specific repetitive approach, i.e. "whoever wants to learn to walk again must walk." However, the physical demands this places on the therapist, is a limiting factor in the clinical routine setting. This article describes a robotic walking simulator for gait training that enables wheelchair-bound subjects to freely carry out repetitive practicing of an individually adapted gait pattern under simulation of the manual guidance of an experienced therapist. The technical principle applied makes use of programmable footplates with permanent foot/machine contact in combination with compliance control. The solution chosen comprises a planar parallel-serial hybrid kinematic system with three degrees of freedom that moves the feet in the sagittal plane. Gait analysis while floor walking and stair climbing, clinical practicability and safety aspects were the basis for the design. A variable compliance control enables man-machine interaction, ranging from purely position controlled movement to full compliance during swing phase above a virtual ground profile. In full compliance mode the robotic walking simulator behaves like a haptic device. The concept presented offers new prospects for individualized gait rehabilitation.  相似文献   

14.
Although alterations in knee joint loading resulting from injury have been shown to influence the development of osteoarthritis, actual in vivo loading conditions of the joint remain unknown. A method for determining in vivo ligament loads by reproducing joint specific in vivo kinematics using a robotic testing apparatus is described. The in vivo kinematics of the ovine stifle joint during walking were measured with 3D optical motion analysis using markers rigidly affixed to the tibia and femur. An additional independent single degree of freedom measuring device was also used to record a measure of motion. Following sacrifice, the joint was mounted in a robotic/universal force sensor test apparatus and referenced using a coordinate measuring machine. A parallel robot configuration was chosen over the conventional serial manipulator because of its greater accuracy and stiffness. Median normal gait kinematics were applied to the joint and the resulting accuracy compared. The mean error in reproduction as determined by the motion analysis system varied between 0.06 mm and 0.67 mm and 0.07 deg and 0.74 deg for the two individual tests. The mean error measured by the independent device was found to be 0.07 mm and 0.83 mm for the two experiments, respectively. This study demonstrates the ability of this system to reproduce in vivo kinematics of the ovine stifle joint in vitro. The importance of system stiffness is discussed to ensure accurate reproduction of joint motion.  相似文献   

15.
The study aimed to test the hypothesis that the restraining role of the anterior cruciate ligament (ACL) of the knee is significant during the activities of normal walking and stair ascent. The role of the ACL was determined from the effect of ACL excision on tibiofemoral displacement patterns measured in vitro for fresh-frozen knee specimens subjected to simulated knee kinetics of walking (n = 12) and stair ascent (n = 7). The knee kinetics were simulated using a newly developed dynamic simulator able to replicate the sagittal-plane knee kinetics with reasonable accuracy while ensuring unconstrained tibiofemoral kinematics. The displacements were measured using a calibrated six degree-of-freedom electromechanical goniometer. For the simulation of the walking cycle, two types of knee flexion/extension moment patterns were used: the more common "biphasic" pattern, and an extensor muscle force intensive pattern. For both of these patterns, the restraining role of the ACL to tibial anterior translation was found to be significant throughout the stance phase and in the terminal swing phase, when the knee angle was in the range of 4 degrees to 30 degrees. The effect of ACL excision was an increase in tibial anterior translation by 4 mm to 5 mm. For the stair ascent cycle, however, the restraining role of the ACL was significant only during the terminal stance phase, and not during the initial and middle segments of the phase. Although, in these segments, the knee moments were comparable to that in walking, the knee angle was in the range of 60 degrees to 70 degrees. These results have been shown to be consistent with available data on knee mechanics and ACL function measured under static loading conditions.  相似文献   

16.
INTRODUCTION: The respective contributions of the active and passive structures of the foot to the stability of the medical arch were investigated using an in vitro kinetic and kinematic model. The effect of the tibialis posterior tendon on foot and ankle movements, and plantar pressure distribution of the foot were tested in a cadaveric human foot. METHOD: The stance phase from heel-contact to toe-off of normal walking gait and after tibialis posterior tendon rupture was simulated in eight roentenographically normal human feet (age 66 +/- 19 years, males). Ground reaction force and tibial inclination was simulated by means of a tilting angle and force-controlled translation stage. Plantar pressure was measured using a pressure-measuring platform. The force developed by the flexors and extensor muscles of the foot were simulated via cables attached to 7 force-controlled hydraulic cylinders. Tibial rotation was produced by an electric servo-motor, and foot movements measured with an ultrasonic analysis system. RESULTS: The model was verified against the plantar distribution and kinematics of healthy subjects measured during normal gait. Tibialis posterior deficit did not result in any detectable changes in pressure or force-time integral in the medial regions of the foot--a common sign of flat foot (pressure: midfoot 0.2 < or = 0.9; medial forefoot 0.5 < or = p < or = 0.9; hallux 0.5 < or = p < or = 0.9; force-time integral: midfoot p = 0-871; medial forefoot p = 0.632; hallux p = 0.068). Only small tendential changes in the kinematics of the talus and calcaneus were observed in dorsiflexion (0-58 sec; talus 0.1 < or = p < or = 0.6; calcaneus 0.4 < or = p < or = 0.06) and eversion (talus: 0-60 sec. 0.1 < or = p < or = 0.6; calcaneus: 37-60 sec. 0.2 < or = p < or = 0.7). CONCLUSION: The results of this in vitro study show that defective tibialis posterior alone does not produce significant changes in the kinetics or kinematics of the stance phase of normal gait. This suggests that the development of flat foot observed in degeneration of the tibialis posterior tendon occurs only after fatigue of the passive structures of the foot.  相似文献   

17.
The experimental evaluation of any total knee replacement (TKR) design should include the pre-implantation quantification of its mechanical performance during tests that simulate the common activities of daily living. To date, few dynamic TKR simulation studies have been conducted before implantation. Once in vivo, the accurate and reproducible assessment of TKR design mechanics is exceedingly difficult, with the secondary variables of the patient and the surgical technique hindering research. The current study utilizes a 6-degree-of-freedom force-controlled knee simulator to quantify the effect of TKR design alone on TKR mechanics during a simulated walking cycle. Results show that all eight TKR designs tested elicited statistically different measures of tibial/femoral kinematics, simulated soft tissue loading, and implant geometric restraint loading during an identical simulated gait cycle, and that these differences were a direct result of TKR design alone. Maximum ranges of tibial kinematics over the eight designs tested were from 0.8mm anterior to 6.4mm posterior tibial displacement, and 14.1 degrees internal to 6.0 degrees external tibial rotation during the walking cycle. Soft tissue and implant reaction forces ranged from 106 and 222N anteriorly to 19 and 127N posteriorly, and from 1.6 and 1.8Nm internally to 3.5 and 5.9Nm externally, respectively. These measures provide valuable experimental insight into the effect of TKR design alone on simulated in vivo TKR kinematics, bone interface loading and soft tissue loading. Future studies utilizing this methodology should investigate the effect of experimentally controlled variations in surgical and patient factors on TKR performance during simulated dynamic activity.  相似文献   

18.
The accurate measurement of the in vivo knee joint kinematics in six degrees-of-freedom (6DOF) remains a challenge in biomedical engineering. We have adapted a dual fluoroscopic imaging system (DFIS) to investigate the various in vivo dynamic knee joint motions. This paper presents a thorough validation of the accuracy and repeatability of the DFIS system when used to measure 6DOF dynamic knee kinematics. First, the validation utilized standard geometric spheres made from different materials to demonstrate the capability of the DFIS technique to determine the object positions under changing speeds. The translational pose of the spheres could be recreated to less than 0.15±0.09 mm for velocities below 300 mm/s. Next, tantalum beads were inserted into the femur and tibia of two fresh frozen cadaver knees to compare the dynamic kinematics measured by matching knee models to the kinematics from the tantalum bead matching—a technique similar to Roentgen stereophotogrammetric analysis (RSA). Each cadaveric knee was attached to the crosshead of a tensile testing machine and vertically translated at a rate of 16.66 mm/s while images were captured with the DFIS. Subsequently, the tibia was held fixed and the femur manually flexed from full extension to 90° of flexion, as the DFIS acquired images. In vitro translation of the cadaver knee using the tensile testing machine deviated from predicted values by 0.08±0.14 mm for the matched knee models. The difference between matching the knee and tantalum bead models during the dynamic flexion–extension motion of the knee was 0.1±0.65°/s in flexion speed; 0.24±0.16 mm in posterior femoral translation; and 0.16±0.61° in internal–external tibial rotation. Finally, we applied the method to investigate the knee kinematics of a living subject during a step ascent and treadmill gait. High repeatability was demonstrated for the in vivo application. Thus, the DFIS provides an easy and powerful tool for accurately determining 6DOF positions of the knee when performing daily functional activities.  相似文献   

19.
The knowledge of articular cartilage contact biomechanics in the knee joint is important for understanding the joint function and cartilage pathology. However, the in vivo tibiofemoral articular cartilage contact biomechanics during gait remains unknown. The objective of this study was to determine the in vivo tibiofemoral cartilage contact biomechanics during the stance phase of treadmill gait. Eight healthy knees were magnetic resonance (MR) scanned and imaged with a dual fluoroscopic system during gait on a treadmill. The tibia, femur and associated cartilage were constructed from the MR images and combined with the dual fluoroscopic images to determine in vivo cartilage contact deformation during the stance phase of gait. Throughout the stance phase of gait, the magnitude of peak compartmental contact deformation ranged between 7% and 23% of the resting cartilage thickness and occurred at regions with thicker cartilage. Its excursions in the anteroposterior direction were greater in the medial tibiofemoral compartment as compared to those in the lateral compartment. The contact areas throughout the stance phase were greater in the medial compartment than in the lateral compartment. The information on in vivo tibiofemoral cartilage contact biomechanics during gait could be used to provide physiological boundaries for in vitro testing of cartilage. Also, the data on location and magnitude of deformation among non-diseased knees during gait could identify where loading and later injury might occur in diseased knees.  相似文献   

20.
Accurate knowledge of the dynamic knee motion in-vivo is instrumental for understanding normal and pathological function of the knee joint. However, interpreting motion of the knee joint during gait in other than the sagittal plane remains controversial. In this study, we utilized the dual fluoroscopic imaging technique to investigate the six-degree-of-freedom kinematics and condylar motion of the knee during the stance phase of treadmill gait in eight healthy volunteers at a speed of 0.67 m/s. We hypothesized that the 6DOF knee kinematics measured during gait will be different from those reported for non-weightbearing activities, especially with regards to the phenomenon of femoral rollback. In addition, we hypothesized that motion of the medial femoral condyle in the transverse plane is greater than that of the lateral femoral condyle during the stance phase of treadmill gait. The rotational motion and the anterior–posterior translation of the femur with respect to the tibia showed a clear relationship with the flexion–extension path of the knee during the stance phase. Additionally, we observed that the phenomenon of femoral rollback was reversed, with the femur noted to move posteriorly with extension and anteriorly with flexion. Furthermore, we noted that motion of the medial femoral condyle in the transverse plane was greater than that of the lateral femoral condyle during the stance phase of gait (17.4±2.0 mm vs. 7.4±6.1 mm, respectively; p<0.01). The trend was opposite to what has been observed during non-weightbearing flexion or single-leg lunge in previous studies. These data provide baseline knowledge for the understanding of normal physiology and for the analysis of pathological function of the knee joint during walking. These findings further demonstrate that knee kinematics is activity-dependent and motion patterns of one activity (non-weightbearing flexion or lunge) cannot be generalized to interpret a different one (gait).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号