首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this work, a highly sensitive acetylcholinesterase (AChE) inhibition-based amperometric biosensor has been developed. Firstly, a glassy carbon electrode (GCE) was modified with chitosan (Chits). Then, hollow gold nanospheres (HGNs) were absorbed onto the surface of chitosan based on the strong affinity through electrostatic adsorption. After that, l-cysteine (l-cys) was assembled on HGNs through Au–S bond. The hollow gold nanospheres were prepared by using Co nanoparticles as sacrificial templates and characterized by scanning electron microscopy, transmission electron microscopy and ultraviolet spectra, respectively. Finally, AChE was immobilized with covalent binding via –COOH groups of l-cysteine onto the modified GCE. The AChE biosensor fabrication process was characterized by cyclic voltammetry and electrochemical impedance spectroscopy methods with the use of ferricyanide as an electrochemical redox indicator. Under optimum conditions, the inhibition rates of pesticides were proportional to their concentrations in the range of 0.1–150 and 0.1–200 μg L?1 for chlorpyrifos and carbofuran, respectively, the detection limits were 0.06 μg L?1 for chlorpyrifos and 0.08 μg L?1 for carbofuran. Moreover, the biosensor exhibited a good stability and reproducibility and was suitable for trace detection of pesticide residues in vegetables and fruits.  相似文献   

2.
In this work, a multiplexed electrochemical immunosensor was developed for sensitive detection of carcinoembryonic antigen (CEA) and α-fetoprotein (AFP) using silver nanoparticles (Ag NPs) or gold nanoparticles (Au NPs) coated-carbon nanospheres (CNSs) as labels. CNSs were employed as the carrier for the immobilization of nanoparticles (Ag NPs or Au NPs), thionine (Thi), and secondary antibodies (Ab2) due to their good monodispersity and uniform structure. Au NPs reduced graphene oxide (rGO) nanocomposites were used as sensing substrate for assembling two primary antibodies (Ab1). In the presence of target proteins, two labels were attached onto the surface of the rGO/Au NPs nanocomposites via a sandwich immunoreaction. Two distinguishable peaks, one at +0.16 V (corresponding to Ag NPs) and another at −0.33 V (corresponding to Thi), were obtained in differential pulse voltammetry (DPV). The peak difference was approximately 490 mV, indicating that CEA and AFP can be simultaneously detected in a single run. Under optimal conditions, the peak currents were linearly related to the concentrations of CEA or AFP in the range of 0.01–80 ng ml−1. The detection limits of CEA and AFP were 2.8 and 3.5 pg ml−1, respectively (at a signal-to-noise ratio of 3). Moreover, when the immunosensor was applied to serum samples, the results obtained were in agreement with those of the reference method, indicating that the immunosensor would be promising in the application of clinical diagnosis and screening of biomarkers.  相似文献   

3.
An electrochemical method for the simultaneous detection of two different tumor markers, carcinoembryonic antigen (CEA) and α-fetoprotein (AFP), in one-pot, using CdS/DNA and PbS/DNA nanochains as labels was developed. Herein, magnetic beads (MBs) as bimolecule immobilizing carriers, were used for co-immobilization of primary anti-CEA and anti-AFP antibodies. The distinguishable signal labels were synthesized by in situ growth of CdS and PbS nanoparticles on DNA chains, respectively, which were further employed to label the corresponding secondary antibodies. A sandwich-type immunoassay format was formed by the biorecognition of the antigens and corresponding antibodies. The assay was based on the peak currents of Cd(2+) and Pb(2+) dissolved from CdS and PbS nanoparticles by HNO(3) using square wave stripping voltammetry. Experimental results show that the multiplexed electrochemical immunoassay has enabled the simultaneous monitoring of CEA and AFP in a single run with wide working ranges of 0.1-100ngmL(-1) for CEA and 0.5-200ngmL(-1) for AFP. The detection limits reach to 3.3pgmL(-1) for CEA and 7.8pgmL(-1) for AFP.  相似文献   

4.
Surface plasmon resonance imaging (SPRi) is an intriguing technique for immunoassay with the inherent advantages of being high throughput, real time, and label free, but its sensitivity needs essential improvement for practical applications. Here, we report a dual signal amplification strategy using functional gold nanoparticles (AuNPs) followed by on-chip atom transfer radical polymerization (ATRP) for sensitive SPRi immunoassay of tumor biomarker in human serum. The AuNPs are grafted with an initiator of ATRP as well as a recognition antibody, where the antibody directs the specific binding of functional AuNPs onto the SPRi sensing surface to form immunocomplexes for first signal amplification and the initiator allows for on-chip ATRP of 2-hydroxyethyl methacrylate (HEMA) from the AuNPs to further enhance the SPRi signal. High sensitivity and broad dynamic range are achieved with this dual signal amplification strategy for detection of a model tumor marker, α-fetoprotein (AFP), in 10% human serum.  相似文献   

5.
A novel scheme for the fabrication of gold nanoparticle modified cholesterol oxidase based bioelectrode is presented and its application potential for cholesterol biosensor is investigated. The fabrication procedure is based on the deposition of gold nanoparticles on the 1,6-hexanedithiol modified gold electrode, functionalization of the surface of deposited gold nanoparticles with carboxyl groups using 11-mercaptoundecanoic acid and then covalent immobilization of cholesterol oxidase on the surface of gold nanoparticle film using the N-ethyl-N'-(3-dimethylaminopropyl carbodimide) and N-hydroxysuccinimide ligand chemistry. The assembly process of the bioelectrode is investigated using atomic force microscopy, cyclic voltammetry and electrochemical impedance spectroscopy. The gold nanoparticle film on the electrode surface provided an environment for the enhanced electrocatalytic activities and thus resulted in enhanced analytical response. The resulting bioelectrode is further applied to the amperometric detection of cholesterol and exhibited a linear response to cholesterol in the range of 0.04-0.22 mM with a detection limit of 34.6 μM, apparent Michaelis-Menten constant (K(m)(app)) of 0.062 mM and a high sensitivity of 9.02 μA mM(-1). The fabricated bioelectrode is successfully used for the selective determination of cholesterol in human serum samples.  相似文献   

6.
Glucose oxidase (GOx) was immobilized onto graphene oxide (GRO) via three different preparation methods: enzyme adsorption (EA), enzyme adsorption and crosslinking (EAC), and enzyme adsorption, precipitation and crosslinking (EAPC). EAPC formulations, prepared via enzyme precipitation with 60% ammonium sulfate, showed 1,980 and 1,630 times higher activity per weight of GRO than those of EA and EAC formulations, respectively. After 59 days at room temperature, EAPC maintained 88% of initial activity, while EA and EAC retained 42 and 45% of their initial activities, respectively. These results indicate that the steps of precipitation and crosslinking in the EAPC formulation are critical to achieve high enzyme loading and stability of EAPC. EA, EAC and EAPC were used to prepare enzyme electrodes for use as glucose biosensors. Optimized EAPC electrode showed 93- and 25-fold higher sensitivity than EA and EAC, respectively. To further increase the sensitivity of EAPC electrode, multi-walled carbon nanotubes (MWCNTs) were mixed with EAPC for the preparation of enzyme electrode. Surprisingly, the EAPC electrode with additional 99.5 wt% MWCNTs showed 7,800-fold higher sensitivity than the EAPC electrode without MWCNT addition. Immobilization and stabilization of enzymes on GRO via the EAPC approach can be used for the development of highly sensitive biosensors as well as to achieve high enzyme loading and stability.  相似文献   

7.
A novel glucose biosensor was developed, based on the immobilization of glucose oxidase (GOD) with cross-linking in the matrix of bovine serum albumin (BSA) on a Pt electrode, which was modified with gold nanoparticles decorated Pb nanowires (GNPs-Pb NWs). Pb nanowires (Pb NWs) were synthesized by an l-cysteine-assisted self-assembly route, and then gold nanoparticles (GNPs) were attached onto the nanowire surface through –SH–Au specific interaction. The morphological characterization of GNPs-Pb NWs was examined by transmission electron microscopy (TEM). Cyclic voltammetry and chronoamperometry were used to study and to optimize the electrochemical performance of the resulting biosensor. The synergistic effect of Pb NWs and GNPs made the biosensor exhibit excellent electrocatalytic activity and good response performance to glucose. The effects of pH and applied potential on the amperometric response of the biosensor have been systemically studied. In pH 7.0, the biosensor showed the sensitivity of 135.5 μA mM−1 cm−2, the detection limit of 2 μM (S/N = 3), and the response time <5 s with a linear range of 5–2200 μM. Furthermore, the biosensor exhibits good reproducibility, long-term stability and relative good anti-interference.  相似文献   

8.
The B-domain, which is one of IgG-binding domains of staphylococcal protein A, was repeated five times and a cysteine residue was introduced at its C-terminus by a genetic engineering technique. The resulting protein, designated B5C1, retained the same IgG-binding activity as native protein A. The B5C1 was assembled on a gold plate surface by utilizing a strong affinity between thiol of cysteine and a gold surface. IgG-binding activity of B5C1 on a gold surface was much higher than that of physically adsorbed B5, which lacks cysteine residue. Furthermore, antigen-binding activity of immobilized antibody molecules through the use of assembled B5C1 on a gold surface was about 4.3 times higher than that of physically adsorbed antibody molecules. Immobilization of highly oriented antibody molecules was realized with the engineered IgG-binding protein.  相似文献   

9.
This paper describes a novel enzymatic amplification strategy for ultrasensitive electrochemical immunosensing. This approach utilizes glucose oxidase for the enzymatic deposition of gold nanoparticles onto an indium tin oxide (ITO) electrode surface using a novel gold developer solution consisting of 20 mM of glucose, 20 mM of NaSCN, 0.5 M of p-benzoquinone (PBQ) and 1 mM of AuCl(4)(-) dissolved in 0.1 M of pH 7.5 phosphate buffer solution. The amount of gold deposited was quantified electrochemically by monitoring the reduction of gold oxide in an aqueous solution of 0.5 M of H(2)SO(4), which was correlated to the amount of antigens in the solution. The effectiveness of this strategy was demonstrated experimentally through the construction of an immunosensor for the detection of mouse IgG using a sandwich immunoassay in a linear dynamic range of 5 pg/ml to 50 ng/ml. A good mean apparent recovery in the range of 88-102% was obtained over the entire linear dynamic range of the sensor response in the serum samples. This suggested that the immunosensor would be useful for the testing of proteins in real clinical samples.  相似文献   

10.
In this article, a novel sandwich-type electrochemical immunosensor based on the signal amplification strategy of diazotization-coupling concept for ultrasensitive detection of carcinoembryonic antigen (CEA) was reported. It operates through physisorption of monoclonal anti-CEA on 4-aminothiophenol (4Atp) functionalized gold electrode interface as the detection platform. Diazo-4Atp-coupled-thionine (Thi)-conjugated gold nanoparticles (GNPs) were prepared for immobilization of horseradish peroxidase (HRP) and secondary anti-CEA to form core-shell bioconjugates that were used as electrochemical signal amplification reagent. The sensitivity of the immunosensor was greatly amplified by a dual amplification: one is that a large number of thionine and HRP was introduced on the electrode surface through sandwich immunoreaction, the other is that HRP as enhancer could catalyze the oxidation reaction of thionine by H(2)O(2), which results in great enhancement of the reduction peak current. Thus, the bioconjugates-based assay provided an amplification approach for detecting CEA at trace levels and led to a detection limit as low as 0.7 pg/mL (at a three times signal-to-noise ratio) that is well-below the threshold value of 2.5 ng/mL for clinical diagnosis. The assay was evaluated for clinical serum samples with various CEA concentrations and received in excellent accordance with the results obtained from the referenced enzyme-linked immunosorbent assay (ELISA).  相似文献   

11.
Polyamidoamine dendrimer (PAMAM) is one of a number of dendritic polymers with precise molecular structure, highly geometric symmetry, and a large number of terminal groups. In this study, different generations of PAMAM (G0-G4) were introduced onto the inner wall of fused-silica capillaries by microwave irradiation and a new type of glucose oxidase (GOx) capillary enzyme microreactor was developed based on enzyme immobilization in the prepared PAMAM-grafted fused-silica capillaries. The optimal enzymolysis conditions for β-d-glucose in the microreactor were evaluated by capillary zone electrophoresis. In addition, the enzymolysis efficiencies of different generations of PAMAM-GOx capillary enzyme microreactor were compared. The results indicate that enzymolysis efficiency increased with increasing generations of PAMAM. The experimental results provide the possibility for the development and application of an online immobilized capillary enzyme microreactor.  相似文献   

12.
The effectiveness of attaching flavin adenine dinucleotide (FAD) via a C bridge to Teflon-bonded carbon black (CB), and the subsequent immobilization of glucose oxidase on the FAD-modified electrodes has been studied by cyclic voltammetry. When FAD alone is bound to the electrode, it undergoes reduction and oxidation at -0.62 and -0.5 V, respectively-values similar to those obtained with free FAD. Compared to the free enzyme, the reduction of FAD as part of the immobilized enzyme is 200 mV more cathodic, while the oxidation potential remains the same in both cases.  相似文献   

13.
In this work, uniform and stable multi-walled carbon nanotubes (MWCT) and chemically reduced graphene (GR) composite electrode interface was fabricated by using layer-by-layer assembly method. The performances of these GR-MWCT assembled electrode interfaces were studied by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). It was demonstrated that the assembled composite film significantly improved the interfacial electron transfer rate compared with that of GR or MWCT modified electrode. Based on the GR-MWCT assembled interface, a sandwich-type electrochemical immunosensor was constructed using human IgG as a model target. In this assay, human IgG was fixed as the target antigen, the HRP-conjugated IgG as the probing antibody and hydroquinone as the electron mediator. The detection limit of the immunosensor was 0.2 ng mL(-1) (signal-to-noise ratio of 3). A good linear relationship between the current signals and the concentrations of Human IgG was achieved from 1 ng mL(-1) to 500 ng mL(-1). Moreover, this electrochemical immunosensor exhibited excellent selectivity, stability and reproducibility, and can be used to accurately detect IgG concentration in human serum samples. The results suggest that the electrochemical immunosensor based on GR-MWCT assembled composite will be promising in the point-of-care diagnostics application of clinical screening of multiple diseases.  相似文献   

14.
In this study, a novel tracer, horseradish peroxidase (HRP) functionalized gold nanorods (Au NRs) nanocomposites (HRP–Au NRs), was designed to label the signal antibodies for sensitive electrochemical measurement of alpha-fetoprotein (AFP). The preparation of HRP–Au NRs nanocomposites and the labeling of secondary antibody (Ab2) were performed by one-pot assembly of HRP and Ab2 on the surface of Au NRs. The immunosensor was fabricated by assembling carbon nanotubes (CNTs), Au NRs, and capture antibodies (Ab1) on the glassy carbon electrode. In the presence of AFP antigen, the labels were captured on the surface of the Au NRs/CNTs via specific recognition of antigen–antibody, resulting in the signal intensity being clearly increased. Differential pulse voltammetry (DPV) was employed to record the response signal of the immunosensor in phosphate-buffered saline (PBS) containing hydrogen peroxide (H2O2) and 3,3′,5,5′-tetramethylbenzidine (TMB). Under optimal conditions, the signal intensity was linearly related to the concentration of AFP in the range of 0.1–100 ng ml−1, and the limit of detection was 30 pg ml−1 (at signal/noise [S/N] = 3). Furthermore, the immunoassay method was evaluated using human serum samples, and the recovery obtained was within 99.0 and 102.7%, indicating that the immunosensor has potential clinical applications.  相似文献   

15.
In this work, a novel chemiluminescence (CL) flow biosensor for glucose was proposed. Glucose oxidase (GOD), horseradish peroxidase (HRP) and gold nanoparticles were immobilized with sol-gel method on the inside surface of the CL flow cell. The CL detection involved enzymatic oxidation of glucose to d-gluconic acid and H(2)O(2), and then the generated H(2)O(2) oxidizing luminol to produce CL emission in the presence of HRP. It was found that gold nanoparticles could remarkably enhance the CL respond of the glucose biosensor. The enhanced effect was closely related to the sizes of gold colloids, and the smaller the size of gold colloids had the higher CL respond. The immobilization condition and the CL condition were studied in detail. The CL emission intensity was linear with glucose concentration in the range of 1.0 x 10(-5)molL(-1) to 1.0 x 10(-3)molL(-1), and the detection limit was 5 x 10(-6)molL(-1) (3sigma). The apparent Michaelis-Menten constant of GOD in gold nanoparticles/sol-gel matrix was evaluated to be 0.3mmolL(-1), which was smaller than that of GOD immobilized in sol-gel matrix without gold nanoparticles. The proposed biosensor exhibited short response time, easy operation, low cost and simple assembly, and the proposed biosensor was successfully applied to the determination of glucose in human serum.  相似文献   

16.
An electrochemical biosensor is described consisting of a thin-layer gold film electrode prepared by cathodic sputtering using a poly(vinyl chloride) sheet as substrate, with voltammetric behaviour comparable to that of conventional polycrystalline gold electrodes, coated with the hydrolysed copolymer hydroxyethyl methacrylate-co-methyl methacrylate onto which glucose oxidase was immobilized. The mechanical properties of the plastic foil substrate permit easy construction of circular-shaped electrodes which were employed as working electrodes for batch injection analysis. The electrochemical biosensor fabrication is inexpensive and can be used as disposable enzyme sensor for the detection of hydrogen peroxide. The biosensor was tested for the determination of glucose in serum and a good correlation was obtained with the measurement using the electrochemical and the spectrophotometric methods.  相似文献   

17.
The ability to immobilize DNA probes onto gold substrates at an optimum surface density is key in the development of a wide range of DNA biosensors. We present a method to accurately control probe DNA surface density by the simultaneous co-immobilization of thiol modified probes and mercaptohexanol. Probe surface density is controlled by the thiol molar ratio in solution, with a linear relationship between thiol molar ratio and probe density spanning (1-9) x10(12)/cm2. The probe surface density per microscopic surface area was determined using chronocoulometry, and a detailed analysis of the method presented. Using this sample preparation method, the effect of probe density and hybridization on the charge transfer resistance with the negatively charged ferri/ferrocyanide redox couple was determined. Above a threshold probe surface density of 2.5 x 10(12)/cm2, electrostatic repulsion from the negatively charged DNA modulates the charge transfer resistance, allowing hybridization to be detected. Below the threshold density no change in charge transfer resistance with probe density or with hybridization occurs. The probe surface density was optimized to obtain the maximum percentage change in charge transfer resistance with hybridization.  相似文献   

18.
Neurogenin3 (ngn3), as a marker for pancreatic endocrine precursor cells and an essential ingredient in the development of islet cells, was quantitatively detected for the first time. Based on a non-cross-linking specific interaction mechanism, a label-free colorimetric immunoassay for the synthetic peptide fragment of ngn3 (SKQRRSRRKKAND) using glutathione (-Glu-Cys-Gly, GSH) functionalized gold nanoparticles (GNPs) is reported. The anti-ngn3 antibody conjugated GNPs (GNP-Ab) was formed through electrostatic interaction upon the addition of anti-ngn3 antibody to the GSH-modified GNPs solution. Monobinding of the positively charged ngn3 to the negatively charged GNP-Ab will minimize the electrostatic repulsion between nanoparticles by neutralizing the surface charge, and then agglomeration is induced by an increasing salt concentration. Under the optimal conditions, the assay showed a linear response range of 50-300 ng/mL for the peptide with a detection limit being 20 ng/mL. The preliminary study on ngn3 opens up an innovative insight to detect short synthetic peptide fragment of antigen, and may own an opportunity for practical applications in clinical diagnosis and therapeutics.  相似文献   

19.
Yin B  Yuan R  Chai Y  Chen S  Cao S  Xu Y  Fu P 《Biotechnology letters》2008,30(2):317-322
A glucose biosensor based on layer-by-layer (LBL) self-assembling of chitosan and glucose oxidase (GOD) on a Prussian blue film was developed. First, Prussian blue was deposited on a cleaned gold electrode then chitosan and GOD were assembled alternately to construct a multilayer film. The resulting amperometric glucose biosensor exhibited a fast response time (within 10 s) and a linear calibration range from 6 μM to 1.6 mM with a detection limit of 3.1 μM glucose (s/n = 3). With the low operating potential, the biosensor showed little interference to the possible interferents, including ascorbic acid, acetaminophen and uric acid, indicating an excellent selectivity.  相似文献   

20.
A novel amperometric glucose sensor was constructed by immobilizing glucose oxidase (GOD) in a titania sol-gel film, which was prepared with a vapor deposition method. The sol-gel film was uniform, porous and showed a very low mass transport barrier and a regular dense distribution of GOD. Titania sol-gel matrix retained the native structure and activity of entrapped enzyme and prevented the cracking of conventional sol-gel glasses and the leaking of enzyme out of the film. With ferrocenium as a mediator the glucose sensor exhibited a fast response, a wide linear range from 0.07 to 15 mM. It showed a good accuracy and high sensitivity as 7.2 microA cm(-2) mM(-1). The general interferences coexisted in blood except ascorbic acid did not affect glucose determination, and coating Nafion film on the sol-gel film could eliminate the interference from ascorbic acid. The serum glucose determination results obtained with a flow injection analysis (FIA) system showed an acceptable accuracy, a good reproducibility and stability and indicated the sensor could be used in FIA determination of glucose. The vapor deposition method could fabricate glucose sensor in batches with a very small amount of enzyme.  相似文献   