首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Augmentation mammaplasty: a comparative analysis   总被引:1,自引:0,他引:1  
With the continuation of augmentation mammaplasty as a desirable operation for a large segment of the female population in the United States, the problem of fibrous capsular contracture that has been present since the inception of the operation has persisted. Various approaches to the problem have been entertained, and a lessening of the incidence has occurred as reviewed in our earlier report, which follows augmentation mammaplasty in our clinic from 1962 through 1979. In this retrospective study, no significant difference in contracture rate was seen based on patient smoking habits, operative approach used, or implant type. It is important to note that the total experience with the low-bleed implant was significantly lower in terms of number of patients meeting the criteria of this retrospective study than the standard gel mammary implant. Greater follow-up time and number of patients will be evaluated in future retrospective studies. We have demonstrated in this study that placement of the implant beneath the pectoral muscle has significantly diminished the incidence of capsular contracture both as Baker grades II, III, and IV and as Baker grades III and IV. The retropectoral site has become the preferred location for the prosthesis in our clinic. There is no appreciable alteration in the overall shape of the breasts from this approach, and therefore, it will continue to be the preferred method. Rates of incidence of hematoma, the most frequent adverse reaction after contracture, were not significantly different between the retropectoral and retromammary implant sites.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
Little has been published regarding the treatment of patients with long-established capsular contracture after previous submuscular or subglandular breast augmentation. This study reviews 7 years of experience in treating established capsular contracture after augmentation mammaplasty by relocating implants to the "dual-plane" or partly subpectoral position. A retrospective chart review was performed on all patients who were treated for capsular contracture using this technique between 1993 and 1999. Data collected included the date of the original augmentation, the original implant location, date of revision and type of implant used, length of follow-up, outcome, and any ensuing complications. Different surgical techniques were used, depending on whether the prior implant was located in a subglandular or submuscular plane. All patients had revisions such that their implants were relocated to a dual plane, with the superior two thirds or so of the implant located beneath the pectoralis major muscle and the inferior one third located subglandularly. Of 85 patients reviewed, 54 had their original implants in a submuscular position and 31 had their initial augmentation in a subglandular position. Of the 54 patients whose implants were initially submuscular, 23 patients (43 percent) had silicone gel implants, 15 patients (28 percent) had double-lumen implants, and the remaining 16 patients (30 percent) had saline implants. Of the 31 patients whose implants were initially subglandular, 20 patients (65 percent) had silicone gel implants, three patients (10 percent) had double-lumen implants, and the remaining eight patients (26 percent) had saline implants. Fifty-one patients (60 percent) had replacement with saline implants (37 smooth saline, 14 textured saline), whereas 34 (40 percent) had silicone gel implants (seven smooth gel, 27 textured gel). The average time from previous augmentation to revision was 9 years 9 months. The average follow-up time after conversion to the dual-plane position was 11.5 months. Only three of 85 patients required reoperation for complications, all of which involved some degree of implant malposition. Of patients converted to the dual plane, 98 percent were free of capsular contracture and were Baker class I at follow-up, whereas 2 percent were judged as Baker class II. There were no Baker level III or IV contractures at follow-up. The dual-plane method of breast augmentation has proved to be an effective technique for correcting established capsular contracture after previous augmentation mammaplasty. This technique appears to be effective when performed with either silicone or saline-filled implants.  相似文献   

3.
The objective of this study was to determine whether the type of capsulectomy, anterior or total, affects the recurrence of capsular contracture around subglandular silicone-gel breast implants. A retrospective analysis was performed of patients who underwent either anterior or total capsulectomy for Baker grade 3 or 4 subglandular capsular contracture in our unit. All patients were invited to a review clinic where their capsular status was assessed. There were 100 anterior- disc capsulectomies in 60 patients between 1988 and 1997 and 99 total capsulectomies in 60 patients between 1990 and 1998. The follow-up in the former group was a median of 7 years and mean 6.9 years, compared with median 2.5 and mean 3.1 years in the latter group. Eighty-six percent of the implants removed from both groups at capsulectomy were smooth-walled gel-filled implants. Sixty-nine breasts in the anterior group received textured gel implants at capsulectomy; the remaining 31 received polyurethane-coated Meme implants. In the total capsulectomy group, all but two breasts (one patient) received textured gel implants. After review, the capsular status was known in 80 percent of the anterior and 92 percent of the total capsulectomy group. The review clinic found eight new contractures in five patients to have developed in the anterior compared with none in the total group. Recurrent contractures affected 50 percent of patients (46 percent of breasts) in the anterior and 11 percent of patients (10 percent of breasts) in the total capsulectomy group. Kaplan-Meier survival analysis was applied to the data. By including only patients who received textured gel implants at capsulectomy, the Logrank found a statistical difference between the two treatment groups (0.01 < p < 0.5). We believe that this study provides some evidence that total capsulectomy for subglandular silicone breast implant capsular contracture results in a lower capsular recurrence than anterior- disc capsulectomy. The pattern and risk of recurrence after total capsulectomy and exchange for a modern textured prosthesis appear to approach those following primary augmentation.  相似文献   

4.
Capsular contracture results in dissatisfaction and deformity among the 2 million women who have had silicone implants. The literature describes contracture rates as high as 74 percent. I present a comparison of rates and incidences of contracture in patients augmented with smooth and textured double-lumen silicone implants. A total of 165 "smooth" and 63 "textured" implant patients were included in this study, which spans 12 years, 1978-1990. All patients underwent bilateral aesthetic augmentation performed by the same surgeon. Of the 165 smooth implant patients, 74 (44.8 percent) experienced contractures requiring treatment. Of the 63 textured implant patients, 3 (4.8 percent) previous contracture patients experienced sudden fibrosis within 3 months. All others remained soft. It appears that deeply textured silicone surfaces delay or decrease the rate and incidence of clinical capsular contracture, at least for 2 years.  相似文献   

5.
The main drawback with augmentation mammaplasty using implants is capsular contracture. The cause of this complication is still unknown. Silicone particles, hematoma, and bacterial contamination are some of the etiologic factors discussed. In this randomized, double-blind study on 76 breast-augmented women, 50 percent of the patients had preoperative prophylaxis with benzylpenicillin and dicloxacillin. Bacteria samples were taken intraoperatively. The number of negative cultures increased significantly with antibiotic prophylaxis. In four follow-ups during the first postoperative year, the rate of contractures was evaluated by subjective and objective methods. The results showed no statistically significant difference between the placebo and the antibiotic group with respect to the incidence of capsular contracture.  相似文献   

6.
Detection of subclinical infection in significant breast implant capsules   总被引:8,自引:0,他引:8  
The pathogenesis of fibrous capsular contracture after augmentation mammaplasty is still debated. One hypothesis implicates low-grade bacterial infections as a cause. The presence of a staphylococcal biofilm in a patient with recurrent capsular contracture was previously reported. A comparative, prospective, blinded, clinical study of implants and capsules removed from patients with or without significant capsular contracture was conducted to investigate the association of biofilm contamination, breast implants, and capsular contracture.Capsule and implant samples obtained during explantation were tested by routine microbiological culture, sensitive broth culture (after maceration and sonication), and scanning electron microscopy. Clinical parameters were correlated with microbiological findings. A total of 48 implant and/or capsule samples were obtained from 27 breasts during a 22-month period. Of the 27 breasts, 19 exhibited significant contracture (Baker grade III/IV). The mean duration of implantation was 9.2 years (range, 0.4 to 26.0 years). Routine swab cultures obtained at the time of explantation were negative for bacterial growth for all samples. The sensitive broth culture technique yielded 24 positive samples (50 percent, n = 48). An analysis of capsules demonstrated that 17 of 19 samples obtained from patients with significant contracture were positive, compared with only one of eight samples obtained from patients with minimal or no contracture (p = 0.0006). Fourteen of the 17 positive cultures from significantly contracted breasts yielded coagulase-negative staphylococci, mainly, species of the Staphylococcus epidermidis group. The presence of coagulase-negative staphylococci was also significantly associated with capsular contracture (p = 0.01). There was no significant difference in the frequency of culture positivity for saline versus silicone implants (p = 0.885). Scanning electron microscopy confirmed the presence of extensive biofilm on implants and within capsules.Biofilm, in particular, S. epidermidis biofilm, was detected for a significant proportion of patients with capsular contracture. This implicates biofilm disease in the pathogenesis of contracture, and strategies for its prevention should be explored.  相似文献   

7.
We conducted a double-blind, retrospective comparison between low-bleed and non-low-bleed (conventional) mammary implants because no controlled study has shown a difference in the degree of capsular contracture between the two types of implants. Twenty-five patients had conventional implants and form group A; twenty-eight patients had low-bleed implants and form group B. All patients had submuscular augmentation. The mean Baker score was 1.51 for group A and 1.04 for group B for the entire patient population and 1.65 for group A and 1.07 for group B for patients with more than 1 year of follow-up. For the entire population, 34 percent of group A and 3.6 percent of group B had a Baker score of 2 or greater. For the population with more than 1 year of follow-up, 42 percent of group A and 7 percent of group B had a Baker score of 2 or greater. There was significantly (p less than 0.007) less contracture with the low-bleed implants for the entire population as well as for those patients with greater than 1 year of follow-up (p less than 0.015).  相似文献   

8.
Following breast augmentation, 100 patients with inflatable saline implants were followed for a period of 6 months to 8 1/2 years. Capsular contracture rate, Baker II or greater, was 3.4 percent. This low rate of capsular contracture is attributed to early manipulation of the implant. The deflation rate was also 3.4 percent. The Heyer-Schulte (Mentor) inflatable implant offers an acceptable low rate of leakage to justify its continued use. It also offers an advantage in correction of asymmetries and yields softer breasts. The replacement of an occasional deflated implant does not appear to pose more than a minor nuisance nor to materially compromise the possibility of an excellent long-term result.  相似文献   

9.
Comparisons between results with randomly allotted silicone-gel and saline-filled prostheses in breast reconstruction after mastectomy led to the following conclusions. Neither prosthesis type is ideal. Leakage from saline-filled implants occurred in 2 of the 37 implants, with resultant deflation. Silicone prostheses had a significantly higher rate of capsular contracture [surgeon's evaluation: 54 percent capsular contracture for silicone-gel compared with 20 percent for saline-filled prostheses (p = 0.006); patients' evaluation for the same figures: 54 percent compared with 29 percent (p = 0.03)]. Other authors have shown the presence of silicone in the tissue around silicone-gel-filled silicone implants, but less or none around saline-filled silicone implants. Since the only difference between the two groups was the randomly allotted implants, we assume that the free silicone around silicone-gel-filled prostheses is the major cause of capsular contracture. Since the saline-filled implants showed a 20 percent capsular contracture rate, there could be other causes of capsular contracture in this study. For prevention of contracture, improved implant encapsulation and use of a less reactive filling substance seem to offer possibilities. Surgical technique should aim to preserve the integrity of the prosthesis.  相似文献   

10.
The aim of this prospective, controlled clinical investigation was to find out if there is a difference in the capsular contracture rate between silicone implants with a smooth or textured surface as the only difference. Twenty-five women with bilateral mammary hypoplasia underwent mammary augmentation. All got a textured implant on one side and a smooth implant on the other. The implants were placed subglandularly. Follow-up examinations were done on six occasions. Three parameters were used for estimation of the tendency to capsular contracture: (1) the patient's opinion on differences in hardness of the breasts, (2) the investigator's classification of capsular contracture, and (3) applanation tonometry. At the end of the follow-up period, after 1 year, all parameters showed with no doubt that the breasts augmented with textured implants had a lower tendency to develop contracting capsules than the breasts augmented with smooth implants.  相似文献   

11.
Although textured silicone breast implants have been shown to reduce the incidence of capsular contracture, there is little evidence if this effect is maintained in the long term. It has been 10 years since the double-blind randomized trial in which 53 patients received either Mentor smooth (26) or textured silicone gel implants (27). Of the 14 patients who were not known to have developed a contracture in the smooth group, 11 were reviewed. Three had bilateral contractures. In the textured group, 18 of the 24 patients not known to have contractures were reviewed. None had developed contractures. At 10 years, the incidence of capsular contracture was 65 percent of patients with smooth implants (an increase of 6 percent on the 3-year results) and 11 percent for the textured implant patients (no change on the 3-year results). A database containing the details of 1100 patients reinforces these results by examining the differences in contracture rates of textured, smooth, and polyurethane-coated implants. The effect of submuscular placement on reducing contracture rates regardless of texturing is discussed, as is the apparent increase in capsular contracture in patients who smoke.  相似文献   

12.
Augmentation mammaplasty by means of the transrectus route   总被引:1,自引:0,他引:1  
A new operative technique has been developed for augmentation mammaplasty. Through an inframammary incision, the anterior rectus sheath is entered, and the pocket is dissected in an entirely submuscular plane. We have performed this procedure in 112 patients to date. Complications have been few. The capsular contracture rate in 90 patients followed for greater than 1 year is 7 percent. The inframammary crease can be lowered using this technique, making mastopexy unnecessary in most patients with moderate ptosis.  相似文献   

13.
In a follow-up of 490 patients with breast implants, neither the size of the prosthesis nor the nature of the surgical procedure (simple augmentation mammaplasty or after subcutaneous mastectomy) increased the incidence of capsular contracture. Hematoma or infection were followed by a higher incidence of capsular contracture. Drainage with suction and the instillation of steroid around the prostheses seemed to be effective in reducing the incidence of capsular contracture. In the steroid-treated group, the need for open surgical treatment was reduced. The recurrence rate after closed capsulotomy, or open capsulotomy, was not significantly different from that following the more extensive procedure of capsulectomy.  相似文献   

14.
Breast conservation therapy (wide local excision, axillary lymph node dissection, and whole-breast irradiation) is an increasingly popular alternative to mastectomy for breast cancer patients. A sizable (and growing) number of breast cancers occur in women with prior augmentation mammaplasty. Augmented breast cancer patients are currently being treated with conservation therapy, but no study has investigated complications and cosmetic results of radiation therapy specifically in this group of women. Between 1981 and 1988, we used conservation therapy in 17 augmented breast cancer patients. Fifteen patients were available for follow-up. In 10 (67 percent), significant capsular contracture occurred in the irradiated breast an average of 12 weeks following completion of treatment. Four patients have undergone revisionary surgery to correct symptoms arising from contracture. This poor outcome contradicts the results reported in previously published studies. We conclude that irradiation of the breast for cancer in augmented women results in a high incidence of scar-tissue contracture and poor cosmetic results.  相似文献   

15.
At the time of immediate breast reconstruction with submuscular implants, 76 consecutive patients (89 breasts) were randomized into two groups. One received a gel-saline, double-lumen implant with 40 cc of saline added to the outer lumen, while the other received the same implant plus 40 cc of saline and 16 mg methyl prednisolone (40 mg%). Patients were followed for a minimum of 3 years. The groups, which were matched for patient age and implant size, were evaluated at 3, 12, 24, and 36 months for capsular contracture, steroid atrophy, and other complications. With completion of the double-blind study, the patients with submuscular gel-saline implants with only saline added had an overall capsular contracture rate of 38 percent at 3 months, 38 percent at 12 months, and 44 percent at 24 and 36 months. Those with methyl prednisolone had an overall capsular contracture rate of 14 percent at 3 months, and this remained unchanged through the end of the study. The rates of all other complications were comparable. Methyl prednisolone in a dose of 16 mg in 40 cc saline (concentration 40 mg%), when used in the outer lumen of a double-lumen gel-saline implant in a submuscular pocket, is both safe and efficacious in reducing the risk of capsular contracture for a minimum of 3 years in patients undergoing immediate breast reconstruction with submuscular mammary implants.  相似文献   

16.
Transaxillary subpectoral augmentation locates the scar in a less visible position in multiple body positions than approaches that locate scars on the aesthetic unit of the breast. In 90 patients, 63 with 2 to 5 years of follow-up, using the surgical technique described, the Baker III/IV capsular contracture rate was 5.6 percent. There was no occurrence of hematoma, periprosthetic space infection, permanent loss of nipple sensation, or significant axillary wound morbidity. Scar results suggest that the axilla is an anatomically favorable location for both high-quality final appearance and minimal visibility. The transaxillary subpectoral approach is an excellent alternative to inframammary and periareolar approaches in all types of breasts requiring augmentation except the ptotic breast or breasts requiring extremely large prostheses.  相似文献   

17.
Cunningham BL  Lokeh A  Gutowski KA 《Plastic and reconstructive surgery》2000,105(6):2143-9; discussion 2150-1
Our center undertook an industry-funded, outcomes-based, multicenter, retrospective review to evaluate the safety and efficacy of saline-filled breast implants. Our review was part of a pre-market approval review process mandated by the U.S. Food and Drug Administration. The design of our review was modeled on a Plastic Surgery Educational Foundation outcomes study previously conducted by our center. For this study, several significant changes were made to our previous protocol, including improved patient tracking, stronger biostatistical support, and a mandatory 10-year minimum patient follow-up period. Physician-reported and patient-reported data on 450 patients with 882 saline-filled breast implants placed between January 1, 1980, and June 30, 1986, were obtained. Mean patient follow-up period was 13.0 years. Most implants (93.9 percent) were placed for breast augmentation. Seventy-four percent were placed in a submammary position; 25.6 percent, subpectorally; and 0.2 percent, subcutaneously. The overall complication rate was 20.2 percent. Reoperation for capsular contracture or implant deflation was necessary in 104 of 450 patients (23.1 percent). Deflation occurred in 73 implants (8.3 percent) and was underreported according to the physicians' record review alone. This deflation rate is higher than the 5.5 percent previously reported by our center. However, 26 of these 73 deflations (35.6 percent) occurred in a single cohort of patients at one center using Surgitek saline implants. If this cohort is excluded, the deflation rate drops to 5.8 percent, a figure more consistent with data published in the literature and found in our previous study. Of the 73 deflations, spontaneous deflation was reported for 50 (74.6 percent), and the remainder were iatrogenic. Actuarial survival of the non-Surgitek implants was 98.4 percent to 99.8 percent at 5 years and 96.9 percent to 98.9 percent at 10 years (95 percent confidence interval). Risk factors for implant deflation included the use of Surgitek saline-filled implants (odds ratio = 17.5, p < 0.01), use of Heyer-Schulte and Mentor model 1800 implants (odds ratio = 3.0, p < 0.01), and implant size greater than 450 cc (odds ratio = 1.01, p < 0.02). Risk factors for capsular contracture included submammary implant position (odds ratio = 2.05, p = 0.03) and implant size greater than 450 cc (odds ratio = 1.01, p < 0.01). Overall, satisfaction was high: 93 percent of patients were "satisfied" or "very satisfied" with their implants. As in our earlier study, risk factors for patient dissatisfaction were reconstruction after mastectomy (odds ratio = 7.6, p = 0.011), significant breast firmness (odds ratio = 6.2, p < 0.001), and patient desire for smaller implants (odds ratio = 3.0, p = 0.020). In conclusion, our review provides additional outcomes-based evidence that saline-filled breast implants remain a safe, effective alternative to silicone gel-filled models.  相似文献   

18.
A major problem after breast reconstruction with augmentation mammaplasty is contracture of the fibrous capsule around the prosthesis. In a series of 72 breasts in 65 women, silicone-gel and saline-filled implants were randomly selected prior to breast reconstruction. The results were judged with respect to consistency, tenderness, wrinkles, and sounds by two independent plastic surgeons according to the breast augmentation classification (BAC) and by the patients themselves. Capsular contracture was found by the surgeons in 50 percent of the gel implant group and in 16 percent of the saline implant group, which is in conformity with the results of the follow-up 5 years earlier. The incidence of deflation was 16 percent in the saline group and occurred in different sizes of both overinflated and underinflated prostheses. The degree of slow leakage from saline implants will be discussed. Despite the high rate of contractures in the gel group, 85 percent of all patients were satisfied with the result of the reconstruction.  相似文献   

19.
D Fagrell  A Berggren  E Tarpila 《Plastic and reconstructive surgery》2001,108(7):2108-12; discussion 2113
In a previous prospective randomized clinical study comparing in the same patient textured and smooth saline-filled mammary implants (Biocell) with large pore size (300 to 600 microm), we saw no difference in capsular contracture. This study was undertaken in a similar way to compare capsular contracture around smooth and textured saline-filled prostheses with pores of small size. During a period of 7.5 years, the breast hardness was followed up, and at the end of the study patient satisfaction was evaluated.Twenty healthy women with a mean age of 30 years were operated on for breast augmentation. Two surgeons performed all operations in a standardized way. Each patient received subglandularly a Siltex textured saline-filled prosthesis with a pore size of 30 to 70 microm in one breast, and a smooth saline-filled prosthesis in the other. The hardness of the breasts was evaluated after 0.5, 1, and 7.5 years using Baker grading and applanation tonometry. Eighteen patients completed 1-year and 7.5-year follow-up. Two breasts with smooth prostheses were contracted after 6 months (Baker III or IV). After 1 year, four patients with smooth prostheses and one with a textured prosthesis had capsular contracture (p = 0.34). Seven and one-half years after surgery, six patents with smooth and four with textured implants had contracture (p = 0.66). On two patients with smooth prostheses and one patient with a textured prosthesis, the capsule around the implant hardened between 6 and 12 months. Between 1 year and 7.5 years, three breasts with smooth and textured implants contracted and one with a textured implant softened.The patients reported on a Visual Analogue Scale (1 to 10) the impact of the augmentation on their quality of life to be 9 +/- 1. Four patients preferred the breast with the smooth prosthesis, three preferred the breast with the textured prosthesis, and the others found both breasts equal. This study showed no significant difference of contracture with smooth versus fine textured implants. The majority of the patients preferred the smooth implants. The patients reported that the breast augmentation had had an extremely high impact on their quality of life.  相似文献   

20.
In various fibrotic diseases, matrix metalloproteinases (MMPs) and their natural inhibitors, the tissue inhibitors of metalloproteinases (TIMPs), play an important role. In our study, serum concentrations of MMP-1, MMP-2, MMP-9, TIMP-1, and TIMP-2 were determined by enzyme-linked immunosorbent assay in 17 female patients with Baker grade II (n =9), III (n =7), and IV (n =1) capsular contracture after bilateral cosmetic mamma augmentation with Trilucent implants (AEI, Inc., Caversham, United Kingdom). Samples of capsular tissue for standard histology and immunohistochemistry were obtained from all patients. Sera from 20 female patients who had plastic surgery for reduction mammaplasty were used as the control group. The aminoterminal propeptide of procollagen type III (PIIINP) and hyaluronan were analyzed as markers for fibrogenesis in both groups, too. Statistical analysis was performed using the Mann-Whitney test and Spearman rank correlation. Patients with capsular contracture presented significantly higher concentrations of TIMP-1 and TIMP-2 in their sera than did the control group (p < 0.05), which correlated with Baker grade (r = 0.7 versus r = 0.65; p < 0.05). The concentration of MMP-2 was significantly higher in the sera of patients with capsule fibrosis, whereas there were no significant differences in MMP-1, MMP-9, and PIIINP serum concentrations. Patients with capsule fibrosis had a significantly lower MMP-to-TIMP ratio (1.1 +/- 0.4, p <0.05) than the control group (1.5 +/- 0.4), which correlated with the Baker classification (r =0.7; p <0.05). The hyaluronan serum concentration of patients with capsular contracture was significantly higher (p < 0.05) and correlated with the Baker grade (r = 0.73; p < 0.05), whereas PIIINP showed no difference. In the histologic evaluation, there was a chronic inflammatory reaction in the capsules around the breast implants and refracting material within the substance. Immunohistochemically, TIMP-1 and TIMP-2 showed an intensive accumulation, and MMP-2 showed a local reaction. PIIINP could be detected, too, whereas there was no staining for MMP-1 and MMP-9.The elevated systemic MMP-2 concentration and the local positive staining in the tissue might be due to the chronic inflammatory reaction. Nevertheless, the balance between MMPs and their natural inhibitors is disturbed in patients with capsule contracture. The elevated systemic concentration of TIMPs might be a pathway in the pathogenesis of severe fibrosis after breast augmentation with alloplastic material. Hyaluronan might be a useful marker for early prediction of capsule fibrosis, whereas PIIINP is not useful as a predictor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号