首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The contents of ginsenosides in Panax ginseng not only vary in different parts of the root, but also exhibit yearly variation. In this study, an HPLC-MS method was established in order to simultaneously analyse ginsenosides Rb1, Rb2, Rb3, Rc, Rd, Re, Rf, Rg1 and Rg2. The concentration of ginsenosides in the tap root and root fibre were compared and the yearly variations of nine ginsenosides elucidated. The results indicate that the total content of ginsenosides in the main root and the root fibre both attain a maximum level in the fourth year of growth, although the amount in the former is much higher than in the latter. The variation in the content of ginsenosides during a 2-6 year period suggests that cultivated P. Ginseng can be harvested after the fourth year. The current results will provide useful information for the quality control and good agricultural practice farming of ginseng.  相似文献   

2.
Here we describe a simple, fast and sensitive liquid chromatography/mass spectrometry method with automated on-line extraction to quantify isatin, an endogenous monoamine oxidase, and atrial natriuretic peptide inhibitor, in urine. After derivatisation of isatin to isatinoxime with hydroxylamine hydrochloride and zinc sulfate precipitation, samples were loaded on the extraction column, washed and, after activation of the column-switching valve, backflushed onto the analytical column. Using electrospray ionisation, [M+H]+ ions could be detected in the selected ion monitoring mode. The assay was linear from 5 to 5000 ng/ml (r2>0.99) and analytical recovery was >80%. Inter-assay precision for the quality control samples was less than 3% and inter-assay accuracy was within +/- 5%.  相似文献   

3.
A new high-performance liquid chromatographic method for simultaneous determination of primidone (PRM) and of its three major metabolites, phenobarbital (PB), p-hydroxyphenobarbital (p-HO-PB) and phenylethylmalonamide (PEMA), in rat urine, was developed. After acid hydrolysis, these compounds were extracted from urine by means of a Bond Elut Certify LRC column with good clean-up. The extracts were chromatographed on a C18 reversed-phase column using isocratic elution at 40°C, with UV detection at 227 nm. The limit of detection was 0.5 mg/ml for the four compounds. Good linearity (r2>0.99) was observed within the calibration ranges studied: 37.4–299.3 μg/ml for PRM, 26.4–211.2 μg/ml for PB, 12.5–100.2 μg/ml for p-HO-PB and 12.1–97.0 μg/ml for PEMA. Repeatability was in the range 3.1–6.8%. This method constitutes a useful tool for studies on the influence of various parameters on primidone metabolism.  相似文献   

4.
A new, highly selective high-performance liquid-chromatographic (HPLC) assay for theophylline and its major metabolites in urine is described. The method utilizes an ion-pair extraction followed by separation and quantitation by reversed-phase ion-pair gradient-elution HPLC. Comparison with several other methods showed that interferences were present in too many blank urine samples to allow for the accurate quantitation of the metabolites of theophylline by direct injection-isocratic HPLC assays. Sample processing involving ion-pair complexing and extraction together with gradient-elution systems is recommended for accurate pharmacokinetic studies.  相似文献   

5.
A rapid, sensitive and reliable high-performance liquid chromatographic-mass spectrometric method for the detection of 25 diuretics in human urine has been developed. Atmosphere pressure chemical ionization (APCI) and electrospray ionization (ESI) modes were evaluated. A 2-ml volume of urine was extracted under basic conditions and separated on an Agilent Zorbax SB-C(18) column (150 x 2.1 mm, 5 microm). The mobile phase consisted of formic ammonium-formic acid buffer (pH 3.5) and acetonitrile. The effects of capillary temperature, sheath gas pressure and compositions of mobile phase on the sensitivity were studied. The recoveries of most of the diuretics were 75-95%. In the full scan mode, the limits of detection of the 25 diuretics were 0.25-25 ng/ml for APCI and 0.6-250 ng/ml for ESI. Under the optimal conditions, 14 diuretics from authentic urine samples were detected successfully by LC-APCI-MS. To obtain more fragmentation information on the chemical structure for positive confirmation, tandem mass analysis was also investigated.  相似文献   

6.
We devised a sensitive and simple method for simultaneous determination of formate and acetate in whole blood and urine from humans using gas chromatography-mass spectrometry. Formate and acetate were alkylated with pentafluorobenzyl bromide in the mixture of acetone and phosphate buffer (pH 6.8). The derivatives obtained were analyzed using gas chromatography-mass spectrometry in positive-ion electron ionization (EI) mode. The lower limit of detection for both compounds was 0.02mM. The calibration curves for formate and acetate were linear over the concentration range from 0.05 to 5.0mM. Accuracy and precision of the method were evaluated and the coefficients of variation were within 10%. With use of this method, levels of formate and acetate in whole blood can be determined in forensic cases.  相似文献   

7.
A sensitive high-performance liquid chromatographic assay for isbufylline and its major metabolites in rabbit blood and urine is described. After extraction, samples were eluted by a linear reversed-phase gradient. Specimens obtained after intravenous administration of isbufylline to rabbits were analysed to identify and subsequently quantify the potential metabolites. Using the ultraviolet absorption trace on the recorder as a reference, elution fractions were collected and analysed by mass spectrometry with the direct inlet system and gas chromatography—mass spectrometry after derivatization. Seven metabolites were identified and another five quantified. The method is specific, accurate, reproducible and recommended for pharmacokinetic studies.  相似文献   

8.
To investigate the trend of non-controlled drugs of abuse, simultaneous analytical methods were developed using GC-MS and LC-ESI-MS for 8 tryptamines/beta-carbolines, 6 phenethylamines of typically non-controlled substances in Japan, and, additionally, five legally controlled tryptamines and phenethylamines originally found in fungi or plants. Moreover, the proposed methods were applied to analyses of these drugs in 99 kinds of products (a total number of 123 products purchased at adult shops or via the Internet over the past 2 years in Japan), which potentially advertised psychotropic/psychoactive effects. The samples were extracted with methanol under ultrasonication. After centrifugation, the extracts were filtered prior to injections. GC-MS analysis was performed using a DB-5MS capillary column. Regarding the LC-ESI-MS analysis; the separation of the target drugs was optimized on an ODS column in acetonitrile/MeOH (7:3)-10 mM ammonium formate buffer (pH 3.5)/acetonitrile (95:5) by a linear gradient program and a quantitative analysis was carried out by the monitoring of each [M+H]+ in the positive ion mode of ESI-MS. As a result of the analyses using GC-MS and LC-ESI-MS, 5-MeO-DIPT (the synthetic substance known by the street name "Foxy") was found in 8 out of the 99 kinds of products. Additionally, AMT (from brown powder), DMT (from dried plant), harmine and harmaline (from dried plant) were also found in some of the 99 products. These analytical methods could be useful for the investigation of the distribution of the non-controlled psychotropic tryptamines/beta-carbolines and phenethylamines in the market.  相似文献   

9.
We have developed a liquid chromatographic-mass spectrometric method for the simultaneous determination of nitroglycerin (NTG) and its active metabolites, glyceryl 1,2-dinitrate (1,2-GDN) and glyceryl 1,3-dinitrate (1,3-GDN), for metabolism studies in cell cultures. 1,2,4-Butanetriol-1,4-dinitrate was chosen as an internal standard. Using a linear gradient of water/methanol containing 0.025 mM NH(4)Cl, the compounds were eluted within 12.5 min on an Allure Aqueous C(18) column (100 mm x 2.1 mm). Detection and quantification was achieved with multiple reaction monitoring in the negative ion mode. Intra- and inter-day variabilities for simultaneous determination of the three nitrates were below 10 and 18%, respectively, over a range of NTG and GDN concentrations of 0.5-15 ng/ml. The lower limit of quantification was found to be about 0.01 ng on column. Application of this method was illustrated through in vitro metabolism studies of NTG in culture media bathing LLC-PK1 cells and human vascular smooth muscle cells (HA-VSMC) at 37 degrees C. The degradation half-life of NTG was found to be 4.5 +/- 0.4 h and 39.2 +/- 0.02 h, respectively, for LLC-PK1 cells versus HA-VSMC. At 5 h, the 1,2-GDN versus 1,3-GDN metabolite distribution ratio in the bathing medium was found to be 1.5 +/- 0.1 and 0.2 +/- 0.02 for LLC-PK1 and HA-VSMC cells, respectively. With this method, the degradation half-life of NTG in rat plasma at 37 degrees C was shown to be 26.8 +/- 1.8 min, consistent with previous values obtained using gas chromatography.  相似文献   

10.
A simple method for the simultaneous determination of oxalic and citric acids has been developed using reversed-phase HPLC. An aqueous solution containing potassium dihydrogenphosphate (0.25%) and tetrabutylammonium hydrogensulphate (2.5 mmol) at pH 2.0 was used as mobile phase. Under these conditions both the components were well resolved and detected at 210 nm. The recovery for oxalic and citric acids was 97% and 102%, respectively. The method presented here was applied to urine specimens of a large number of urolithic patients and control subjects. Because of the simplicity of the method its application provides better means of monitoring the concentration of oxalic and citric acids in the formation of renal calculi.  相似文献   

11.
We devised a sensitive and simple method to simultaneously determine bromvalerylurea and allylisopropylacetylurea in human blood and urine by gas chromatography-mass spectrometry. Bromvalerylurea and allylisopropylacetylurea were extracted using an Extrelut column with an internal standard, 2-bromohexanoylurea, followed by derivatization with heptafluorobutyric anhydride. The derivatized extract was submitted to GC-MS analysis of EI-SIM mode. The calibration curves of both compounds were linear in the concentration range from 0.01 to 10 microg/ml in both blood and urine samples. The lower limits of detection of bromvalerylurea and allylisopropylacetylurea were 0.005 and 0.005 microg/ml, respectively. This method proved most useful in accurately identifying these drugs in blood and urine from an autopsied individual.  相似文献   

12.
A simple and sensitive high-performance liquid chromatographic method for the simultaneous assay of amiodarone and desethylarniodarone in plasma, urine and tissues has been developed. The method for plasma samples and tissue samples after homogenizing with 50% ethanol, involves deproteinization with acetonitrile containing the internal standard followed by centrifugation and direct injection of the supernatant into the liquid chromatograph. The method for urine specimens includes extraction with a diisopropyl ether—acetonitrile (95:5, v/v) mixture at pH 7.0 using disposable Clin-Elut 1003 columns, followed by evaporation of the eluate, reconstitution of the residue in methanol—acetonitrile (1:2, v/v) mixture and injection into the chromatograph. Separation was obtained using a Radial-Pak C18 column operating in combination with a radial compression separation unit and a methanol–25% ammonia (99.3:0.7, v/v) mobile phase. A wavelength of 242 nm was used to monitor amiodarone, desethylamiodarone and the internal standard. The influence of the ammonia concentration in the mobile phase on the capacity factors of amiodarone, desethylamiodarone and two other potential metabolites, monoiodoamiodarone (L6355) and desiodoamiodarone (L3937) were investigated. Endogenous substances or a variety of drugs concomitantly used in amiodarone therapy did not interfere with the assay.The limit of sensitivity of the assay was 0.025 μg/ml with a precision of ± 17%. The inter- and intra-day coefficient of variation for replicate analyses of spiked plasma samples was less than 6%. This method has been demonstrated to be suitable for pharmacokinetic and metabolism studies of amiodarone in man.  相似文献   

13.
A gas chromatography-mass spectrometric (GC-MS) method was developed for the determination of 2-naphthol (2-NAP) and 1-hydroxypyrene (1-HOP) in human urine. Extraction from urine after the enzyme hydrolysis with β-glucuronidase/arylsulfatase was achieved with a liquid extraction using 5 mL of pentane. After addition of 50 μL of N-methyl-N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBDMSTFA) to prevent the loss of 2-NAP during drying, the extract was completely dried and derivatized with MTBDMSTFA for 30 min at 60 °C. The accuracies were in the range of 96-109% at a concentration of 0.5, 10 and 25 μg/L and their precisions were less than 15%. Method detection limits of 2-NAP and 1-HOP were 0.07 and 0.01 μg/L, respectively. This method was used to analyze twenty urine samples, and they were found in the concentration range <0.07-13.7 μg/L (2-NAP) and <0.01-0.88 μg/L (1-HOP). The concentrations of 2-NAP and 1-HOP were well correlated to those of naphthalene and pyrene in blood, respectively.  相似文献   

14.
Eleven castrated male pigs weighing 88.1?±?3.9?kg on average were adapted to a diet containing DON (4.2?mg DON/kg) over a period of 7 days. Feed was given restrictively with 1.1?kg per meal (two meals per day). On the day of measurement, all pigs were slaughtered at different time intervals following the morning meal containing DON (1, 2, 3, 4, 5, 6, 8, 15, 18 and 24?h after feeding), with the exception of one pig which was slaughtered unfed. DON and de-epoxy-DON were analysed in serum and digesta from consecutive segments of the digestive tract (stomach, small intestine divided into three parts of a similar length, caecum, colon, rectum). DON was rapidly and nearly completely absorbed while passing through the stomach and the proximal small intestine. Maximum serum concentration appeared 4.1?h after the DON-containing meal and half of the systemically absorbed DON was eliminated after 5.8?h. De-epoxy-DON appeared in increasing proportions from the distal small intestine and reached approximately 80% of the sum of DON plus de-epoxy-DON in faeces collected from the rectum. It was concluded that de-epoxydation of DON, which primarily occurs in the hindgut, probably does not contribute much to a detoxification in the pig.  相似文献   

15.
A rapid, selective and sensitive method for the simultaneous determination of chlorpromazine and levomepromazine in human plasma and urine has been developed using high-performance liquid chromatography with electrochemical detection.The unchanged drugs and internal standard extracted from plasma and urine were separated by reversed-phase high-performance liquid chromatography. The influence of acetonitrile concentration and of the pH of the mobile phase were investigated. The detection limits were 100 pg for chlorpromazine and for levomepromazine. In comparison with three other detection systems this was found to be the most sensitive method.This method was successfully applied to the simultaneous determination of chlorpromazine and levomepromazine in human plasma and urine for pharmacokinetic studies.  相似文献   

16.
17.
A method based on liquid chromatography tandem mass spectrometry (LC-MSMS) applying atmospheric pressure chemical ionisation (APCI) in the positive ion mode was developed for the direct determination of nicotine, cotinine, trans-3'-hydroxycotinine, their corresponding glucuronide conjugates as well as cotinine-N-oxide, norcotinine, and nicotine-N'-oxide in the urine of smokers. The assay involves filtration of crude urine, fast liquid chromatography on a reversed-phase column and mass-specific detection using MSMS transitions. Deuterium-labeled nicotine, cotinine, and trans-3'-hydroxycotinine were used as internal standards. Glucuronides used as reference material were either chemically (cotinine-N-glucuronide) or enzymatically synthesized (nicotine-N-glucuronide and trans-3'-hydroxycotinine-O-glucuronide). Precision for the major nicotine analytes at levels observable in urine of smokers was better than 10%. Accuracy expressed in recovery rates in urine matrix for nicotine, cotinine, trans-3'-hydroxycotinine, and cotinine-N-glucuronide ranged from 87 to 113%. Quantitative results for the three glucuronides in urine samples of 15 smokers were compared to an indirect method in which the aglycons were determined with gas chromatography and nitrogen-selective detection (GC-NPD) before and after enzymatic splitting of the conjugates. Good agreement was found for cotinine-N-glucuronide (coefficient of variation, CV: 9%) and trans-3'-hydroxycotinine-O-glucuronide (CV: 20%), whereas the accordance between both methods was moderate for nicotine-N-glucuronide (CV: 33%). The described LC-MSMS method allows the simultaneous determination of nicotine and eight of its major metabolites in urine of smokers with good precision and accuracy. Since the method requires a minimum of sample clean-up and a very short time for chromatography (3 min), it is suitable for determining the nicotine dose in large-scale human biomonitoring studies.  相似文献   

18.
A new high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) assay for cediranib, a tyrosine kinase inhibitor for VEGFRs, was developed and validated, for the determination of plasma and brain levels of cediranib in small specimen volumes. Tyrphostin (AG1478) was used as internal standard. Mouse plasma and brain homogenate samples were prepared using liquid-liquid extraction. The assay was validated for a 2.5-2500 ng/mL concentration range for plasma, and for 1-2000 ng/mL range for brain homogenate. For these calibration ranges, within-assay variabilities were 1.1-14.3% for plasma and 1.5-9.4% for brain homogenate; between-assay variabilities were 2.4-9.2% for plasma, and 4.9-10.2% for brain homogenate. Overall accuracy ranged from 101.5 to 107.0% for plasma and 96.5 to 100.2% for brain homogenate, for all target concentrations. The developed assay has been successfully applied for a brain distribution study in mice at an oral dose of 5 mg/kg.  相似文献   

19.
Alkylresorcinols (AR) are amphiphilic compounds present at high concentrations in the outer parts of wheat and rye kernels. Due to their specificity to whole grain and bran products of these cereals, AR and their metabolites have been proposed as biomarkers for intake of such foods. Two alkylresorcinol metabolites, 3,5-dihydroxybenzoic acid (DHBA) and 3-(3,5-dihydroxyphenyl)-1-propanoic acid (DHPPA), have previously been quantified in human urine using two different methodologies: high-performance liquid chromatography coupled to a coulometric electrode array detector (HPLC-CEAD) and gas chromatography in combination with mass spectrometry (GC-MS). In this study, these two methodologies were compared by analysing 114 urine samples from free-living Swedish subjects consuming their habitual diet. Data were evaluated by graphical investigation of difference-plots and statistical inference of agreement was assessed by weighted Deming regression analysis. The median DHBA concentrations were 11 μM (GC-MS) and 13 μM (HPLC-CEAD), respectively. Both difference-plot and regression analysis showed a small but statistically significant additive bias, with HPLC-CEAD resulting in a slightly higher DHBA concentration than GC-MS. The median concentration of DHPPA was 18 μM for both methods. Examination of the difference-plot of DHPPA did not indicate any systematic difference between the methods, but regression analysis showed small but statistically significant constant and proportional biases. The conclusion was that the two methodologies are equally suitable for analysis of alkylresorcinol metabolites in human urine and that any small systematic differences observed are most likely of limited practical importance.  相似文献   

20.
A high-performance liquid chromatographic method was developed for the simultaneous determination of phenylbutazone and its metabolites, oxyphenbutazone and γ-hydroxyphenylbutazone, in plasma and urine. Samples were acidified with hydrochloric acid and extracted with benzene—cyclohexane (1:1, v/v). The extract was redissolved in methanol and chromatographed on a μBondapak C15 column using a mobile phase of methanol—0.01 M sodium acetate buffer (pH 4.0) in a linear gradient (50 to 100% methanol at 5%/min; flow-rate 2.0 ml/min) in a high-performance liquid chromatograph equipped with an ultra-violet absorbance detector (254 nm). The detection limit for phenylbutazone, oxyphenbutazone and for γ-hydroxyphenylbutazone was 0.05 μg/ml.A precise and sensitive assay for the determination of phenylbutazone and its metabolites was established.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号