Study design

Retrospective study.

Objective

To evaluate the radiological results of fusion with segmental pedicle screw fixation in juvenile idiopathic scoliosis with a minimum 5-year follow-up.

Summary of background data

Progression of spinal deformity after posterior instrumentation and fusion in immature patients has been reported by several authors. Segmental pedicle screw fixation has been shown to be effective in controlling both coronal and sagittal plane deformities. However, there is no long term study of fusion with segmental pedicle screw fixation in these group of patients.

Methods

Seven patients with juvenile idiopathic scoliosis treated by segmental pedicle screw fixation and fusion were analyzed. The average age of the patients was 7.4 years (range 5–9 years) at the time of the operation. All the patients were followed up 5 years or more (range 5–8 years) and were all Risser V at the most recent follow up. Three dimensional reconstruction of the radiographs was obtained and 3DStudio Max software was used for combining, evaluating and modifying the technical data derived from both 2d and 3d scan data.

Results

The preoperative thoracic curve of 56 ± 15° was corrected to 24 ± 17° (57% correction) at the latest follow-up. The lumbar curve of 43 ± 14° was corrected to 23 ± 6° (46% correction) at the latest follow-up. The preoperative thoracic kyphosis of 37 ± 13° and the lumbar lordosis of 33 ± 13° were changed to 27 ± 13° and 42 ± 21°, respectively at the latest follow-up. None of the patients showed coronal decompensation at the latest follow-up. Four patients had no evidence of crankshaft phenomenon. In two patients slight increase in Cobb angle at the instrumented segments with a significant increase in AVR suggesting crankshaft phenomenon was seen. One patient had a curve increase in both instrumented and non instrumented segments due to incorrect strategy.

Conclusion

In juvenile idiopathic curves of Risser 0 patients with open triradiate cartilages, routine combined anterior fusion to prevent crankshaft may not be warranted by posterior segmental pedicle screw instrumentation.  相似文献   

2.

Background

Several methods including free-hand technique, fluoroscopic guidance, image-guided navigation, computer-assisted surgery system, robotic platform and patient’s specific templates are being used for pedicle screw placement. These methods have screw misplacements and are not always easy to be applied. Furthermore, it is necessary to expose completely a large portions of the spine in order to access fit entirely around the vertebrae.

Methods

In this study, a multi-level patient’s specific template with medium invasiveness was proposed for pedicle screw placement in the scoliosis surgery. It helps to solve the problems related to the soft tissues removal. After a computer tomography (CT) scan of the spine, the templates were designed based on surgical considerations. Each template was manufactured using three-dimensional printing technology under a semi-flexible post processing. The templates were placed on vertebras at four points—at the base of the superior-inferior articular processes on both left–right sides. This helps to obtain less invasive and more accurate procedure as well as true-stable and easy placement in a unique position. The accuracy of screw positions was confirmed by CT scan after screw placement.

Results

The result showed the correct alignment in pedicle screw placement. In addition, the template has been initially tested on a metal wire series Moulage (height 70 cm and material is PVC). The results demonstrated that it could be possible to implement it on a real patient.

Conclusions

The proposed template significantly reduced screw misplacements, increased stability, and decreased the sliding & the intervention invasiveness.
  相似文献   

3.

Background

In our institution, the fixation technique in treating idiopathic scoliosis was shifted from hybrid fixation to the all-screw method beginning in 2000. We conducted this study to assess the intermediate -term outcome of all-screw method in treating adolescent idiopathic scoliosis (AIS).

Methods

Forty-nine consecutive patients were retrospectively included with minimum of 5-year follow-up (mean, 6.1; range, 5.1-7.3 years). The average age of surgery was 18.5 ± 5.0 years. We assessed radiographic measurements at preoperative (Preop), postoperative (PO) and final follow-up (FFU) period. Curve correction rate, correction loss rate, complications, accuracy of pedicle screws and SF-36 scores were analyzed.

Results

The average major curve was corrected from 58.0 ± 13.0° Preop to 16.0 ± 9.0° PO(p < 0.0001), and increased to 18.4 ± 8.6°(p = 0.12) FFU. This revealed a 72.7% correction rate and a correction loss of 2.4° (3.92%). The thoracic kyphosis decreased little at FFU (22 ± 12° to 20 ± 6°, (p = 0.25)). Apical vertebral rotation decreased from 2.1 ± 0.8 PreOP to 0.8 ± 0.8 at FFU (Nash-Moe grading, p < 0.01). Among total 831 pedicle screws, 56 (6.7%) were found to be malpositioned. Compared with 2069 age-matched Taiwanese, SF-36 scores showed inferior result in 2 variables: physical function and role physical.

Conclusion

Follow-up more than 5 years, the authors suggest that all-screw method is an efficient and safe method.  相似文献   

4.
5.

Background

There are no reports describing complications with posterior spinal fusion (PSF) with segmental spinal instrumentation (SSI) using pedicle screw fixation in patients with neuromuscular scoliosis.

Methods

Fifty neuromuscular patients (18 cerebral palsy, 18 Duchenne muscular dystrophy, 8 spinal muscular atrophy and 6 others) were divided in two groups according to severity of curves; group I (< 90°) and group II (> 90°). All underwent PSF and SSI with pedicle screw fixation. There were no anterior procedures. Perioperative (within three months of surgery) and postoperative (after three months of surgery) complications were retrospectively reviewed.

Results

There were fifty (37 perioperative, 13 postoperative) complications. Hemo/pneumothorax, pleural effusion, pulmonary edema requiring ICU care, complete spinal cord injury, deep wound infection and death were major complications; while atelectesis, pneumonia, mild pleural effusion, UTI, ileus, vomiting, gastritis, tingling sensation or radiating pain in lower limb, superficial infection and wound dehiscence were minor complications. Regarding perioperative complications, 34(68%) patients had at least one major or one minor complication. There were 16 patients with pulmonary, 14 with abdominal, 3 with wound related, 2 with neurological and 1 cardiovascular complications, respectively. There were two deaths, one due to cardiac arrest and other due to hypovolemic shock. Regarding postoperative complications 7 patients had coccygodynia, 3 had screw head prominence, 2 had bed sore and 1 had implant loosening, respectively. There was a significant relationship between age and increased intraoperative blood loss (p = 0.024). However it did not increased complications or need for ICU care. Similarly intraoperative blood loss > 3500 ml, severity of curve or need of pelvic fixation did not increase the complication rate or need for ICU. DMD patients had higher chances of coccygodynia postoperatively.

Conclusion

Although posterior-only approach using pedicle screw fixation had good correction rate, complications were similar to previous reports. There were few unusual complications like coccygodynia.  相似文献   

6.

Background

Patients with aero-digestive malignancy will often require a feeding gastrostomy during their treatment to maintain their nutritional status. These are usually placed percutaneously using an endoscopic technique.

Case presentation

A fifty-six year old male underwent placement of a percutaneous gastrostomy (PEG) prior to commencement of his treatment for an oral squamous cell carcinoma. The treatment for this was locally curative. However, he developed a metastasis at the site of his PEG tube. This was excised en-bloc with the anterior gastric and abdominal walls.

Conclusion

Tumour implantation into wounds has been previously reported. In this case the direct trauma of passing the PEG tube through the oropharynx led to implantation of cells in the anterior abdominal wall. In these cases laparoscopic placement may be more beneficial to avoid this problem.  相似文献   

7.

Background

Short-segment pedicle screw instrumentation (SSPI) is used for unstable burst fractures to correct deformity and stabilize the spine for fusion. However, pedicle screw loosening, pullout, or breakage often occurs due to the large moment applied during spine motion, leading to poor outcomes. The purpose of this study was to test the ability of a newly designed device, the Trans-Endplate Pedicle Pillar System (TEPPS), to enhance SSPI rigidity and decrease the screw bending moment with a simple posterior approach.

Methods

Six human cadaveric spines (T11-L3) were harvested. A burst fracture was created at L1, and the SSPI (Moss Miami System) was used for SSPI fixation. Strain gauge sensors were mounted on upper pedicle screws to measure screw load bearing. Segmental motion (T12-L2) was measured under pure moment of 7.5 Nm. The spine was tested sequentially under 4 conditions: intact; first SSPI alone (SSPI-1); SSPI+TEPPS; and second SSPI alone (SSPI-2).

Results

SSPI+TEPPS increased fixation rigidity by 41% in flexion/extension, 28% in lateral bending, and 37% in axial rotation compared with SSPI-1 (P<0.001), and it performed even better compared to SSPI-2 (P<0.001 for all). Importantly, the bending moment on the pedicle screws for SSPI+TEPPS was significantly decreased 63% during spine flexion and 47% in lateral bending (p<0.001).

Conclusion

TEPPS provided strong anterior support, enhanced SSPI fixation rigidity, and dramatically decreased the load on the pedicle screws. Its biomechanical benefits could potentially improve fusion rates and decrease SSPI instrumentation failure.  相似文献   

8.

Objective

To introduce a robot-assisted surgical system for spinal posterior fixation that can automatically recognize the drilling state and stop potential cortical penetration with force and image information and to further evaluate the accuracy and safety of the robot for sheep vertebra pedicle screw placement.

Methods

The Robotic Spinal Surgery System (RSSS) was composed of an optical tracking system, a navigation and planning system, and a surgical robot equipped with a 6-DOF force/torque sensor. The robot used the image message and force signals to sense the different operation states and to prevent potential cortical penetration in the pedicle screw insertion operation. To evaluate the accuracy and safety of the RSSS, 32 screw insertions were conducted. Furthermore, six trajectories were deliberately planned incorrectly to explore whether the robot could recognize the different drilling states and immediately prevent cortical penetration.

Results

All 32 pedicle screws were placed in the pedicle without any broken pedicle walls. Compared with the preoperative planning, the average deviations of the entry points in the axial and sagittal views were 0.50±0.33 and 0.65±0.40 mm, and the average deviations of the angles in the axial and sagittal views were 1.9±0.82° and 1.48±1.2°. The robot successfully recognized the different drilling states and prevented potential cortical penetration. In the deliberately incorrectly planned trajectory experiments, the robot successfully prevented the cortical penetration.

Conclusion

These results verified the RSSS’s accuracy and safety, which supported its potential use for the spinal surgery.  相似文献   

9.

Background Context

Animals are commonly used to model the human spine for in vitro and in vivo experiments. Many studies have investigated similarities and differences between animals and humans in the lumbar and thoracic vertebrae. However, a quantitative anatomic comparison of calf, pig, and human cervical spines has not been reported.

Purpose

To compare fundamental structural similarities and differences in vertebral bodies from the cervical spines of commonly used experimental animal models and humans.

Study Design

Anatomical morphometric analysis was performed on cervical vertebra specimens harvested from humans and two common large animals (i.e., calves and pigs).

Methods

Multiple morphometric parameters were directly measured from cervical spine specimens of twelve pigs, twelve calves and twelve human adult cadavers. The following anatomical parameters were measured: vertebral body width (VBW), vertebral body depth (VBD), vertebral body height (VBH), spinal canal width (SCW), spinal canal depth (SCD), pedicle width (PW), pedicle depth (PD), pedicle inclination (PI), dens width (DW), dens depth (DD), total vertebral width (TVW), and total vertebral depth (TVD).

Results

The atlantoaxial (C1–2) joint in pigs is similar to that in humans and could serve as a human substitute. The pig cervical spine is highly similar to the human cervical spine, except for two large transverse processes in the anterior regions ofC4–C6. The width and depth of the calf odontoid process were larger than those in humans. VBW and VBD of calf cervical vertebrae were larger than those in humans, but the spinal canal was smaller. Calf C7 was relatively similar to human C7, thus, it may be a good substitute.

Conclusion

Pig cervical vertebrae were more suitable human substitutions than calf cervical vertebrae, especially with respect to C1, C2, and C7. The biomechanical properties of nerve vascular anatomy and various segment functions in pig and calf cervical vertebrae must be considered when selecting an animal model for research on the spine.  相似文献   

10.

Background

This study evaluates the outcome and complications of decompressive cervical Laminectomy and lateral mass screw fixation in 110 cases treated for variable cervical spine pathologies that included; degenerative disease, trauma, neoplasms, metabolic-inflammatory disorders and congenital anomalies.

Methods

A retrospective review of total 785 lateral mass screws were placed in patients ages 16-68 years (40 females and 70 males). All cases were performed with a polyaxial screw-rod construct and screws were placed by using Anderson-Sekhon trajectory. Most patients had 12-14-mm length and 3.5 mm diameter screws placed for subaxial and 28-30 for C1 lateral mass. Screw location was assessed by post operative plain x-ray and computed tomography can (CT), besides that; the facet joint, nerve root foramen and foramen transversarium violation were also appraised.

Results

No patients experienced neural or vascular injury as a result of screw position. Only one patient needed screw repositioning. Six patients experienced superficial wound infection. Fifteen patients had pain around the shoulder of C5 distribution that subsided over the time. No patients developed screw pullouts or symptomatic adjacent segment disease within the period of follow up.

Conclusion

decompressive cervical spine laminectomy and Lateral mass screw stabilization is a technique that can be used for a variety of cervical spine pathologies with safety and efficiency.  相似文献   

11.

Background

Accurate placement of pedicle screw during Anterior Transpedicular Screw fixation (ATPS) in cervical spine depends on accurate anatomical knowledge of the vertebrae. However, little is known of the morphometric characteristics of cervical vertebrae in Chinese population.

Methods

Three-dimensional reconstructions of CT images were performed for 80 cases. The anatomic data and screw fixation parameters for ATPS fixation were measured using the Mimics software.

Findings

The overall mean OPW, OPH and PAL ranged from 5.81 to 7.49 mm, 7.77 to 8.69 mm, and 33.40 to 31.13 mm separately, and SPA was 93.54 to 109.36 degrees from C3 to C6, 104.99 degrees at C7, whereas, 49.00 to 32.26 degrees from C4 to C7, 46.79 degrees at C3 (TPA). Dl/rSIP had an increasing trend away from upper endplate with mean value from 1.87 to 5.83 mm. Dl/rTIP was located at the lateral portion of the anterior cortex of vertebrae for C3 to C5 and ipsilateral for C6 to C7 with mean value from −2.70 to −3.00 mm, and 0.17 to 3.18 mm. The entrance points for pedicular screw insertion for C3 to C5 and C6 to C7 were recommended −2∼−3 mm and 0–4 mm from the median sagittal plane, respectively, 1–4 mm and 5–6 mm from the upper endplate, with TPA being 46.79–49.00 degrees and 40.89–32.26 degrees, respectively, and SPA being 93.54–106.69 degrees and 109.36–104.99 degrees, respectively. The pedicle screw insertion diameter was recommended 3.5 mm (C3 and C4), 4.0 mm (C5 to C7), and the pedicle axial length was 21–24 mm for C3 to C7 for both genders. However, the ATPS insertion in C3 should be individualized given its relatively small anatomical dimensions.

Conclusions

The data provided a morphometric basis for the ATPS fixation technique in lower cervical fixation. It will help in preoperative planning and execution of this surgery.  相似文献   

12.

Study Design

A retrospective study of intradural extramedullary tumor.

Objective

To compare the treatment results in the different surgeries of spinal intradural extramedullary tumor.

Methods

The study retrospectively reviewed 122 patients. The minimally invasive surgery (MIS) group was divided into Group A (hemilaminectomy + tumor microscopic excision) and Group B (laminectomy + tumor microscopic excision + pedicle screw fixation). Meanwhile, the non-MIS group was divided into Group C (hemilaminectomy + tumor excision), Group D (laminectomy + tumor excision), and Group E (laminectomy + tumor excision + pedicle screw fixation). In order to study postoperative spinal stability, we simultaneously divided all of the subjects into three categories, namely Group HE: hemilaminectomy + tumor excision; Group LE: laminectomy + tumor excision; and Group LEPSF: laminectomy + tumor excision + pedicle screw fixation.

Results

The MIS group exhibited fewer postoperative complications (p<0.05), better short-term clinical efficacy (p<0.05) and less non-surgical cost (p<0.05) than in non-MIS group. The rate of postoperative spinal instability in hemilaminectomy was lower than in laminectomy in a single spinal segment (p<0.05). The rate of postoperative spinal instability in laminectomy + pedicle screw fixation was lower than in hemilaminectomy and laminectomy in two or more spinal segments (p<0.05).

Conclusion

In the case of appropriate surgical indications, minimally invasive surgery for intradural extramedullary tumor is a useful method that can successfully produce good clinical results and reduce non-surgical cost. In addition, pedicle screw fixation helps avoid spinal postoperative instability.  相似文献   

13.
14.
IntroductionPedicle screws are commonly employed to restore spinal stability and correct deformities. The Renaissance robotic system was developed to improve the accuracy of pedicle screw placement.PurposeIn this study, we developed an intraoperative classification system for evaluating the accuracy of pedicle screw placements through secondary registration. Furthermore, we evaluated the benefits of using the Renaissance robotic system in pedicle screw placement and postoperative evaluations. Finally, we examined the factors affecting the accuracy of pedicle screw implantation.ResultsThrough use of the Renaissance robotic system, the accuracy of Kirschner-wire (K-wire) placements deviating <3 mm from the planned trajectory was determined to be 98.74%. According to our classification system, the robot-guided pedicle screw implantation attained an accuracy of 94.00% before repositioning and 98.74% after repositioning. However, the malposition rate before repositioning was 5.99%; among these placements, 4.73% were immediately repositioned using the robot system and 1.26% were manually repositioned after a failed robot repositioning attempt. Most K-wire entry points deviated caudally and laterally.ConclusionThe Renaissance robotic system offers high accuracy in pedicle screw placement. Secondary registration improves the accuracy through increasing the precision of the positioning; moreover, intraoperative evaluation enables immediate repositioning. Furthermore, the K-wire tends to deviate caudally and laterally from the entry point because of skiving, which is characteristic of robot-assisted pedicle screw placement.  相似文献   

15.

Background

A cursory review of the current socket preservation literatures well depicts the necessity of further esthetic considerations through the corrective procedures of the alveolar ridge upon and post extraction. A new technique has been described here is a rotational pedicle combined epithelialized and connective tissue graft (RPC graft) adjunct with immediate guided tissue regeneration (GBR) procedure.

Results

We reviewed this technique through a case report and discuss it??s benefit in compare to other socket preservation procedures.

Conclusion

The main advantages of RPC graft would be summarized as follows: stable primary closure during bone remodeling, saving or crating sufficient vestibular depth, making adequate keratinized gingiva on the buccal surface, and being esthetically pleasant.  相似文献   

16.

Purpose

This study aims to investigate the feasibility of a novel lumbar approach named extraforaminal lumbar interbody fusion (ELIF), a newly emerging minimally invasive technique for treating degenerative lumbar disorders, using a digitalized simulation and a cadaveric study.

Methods

The ELIF surgical procedure was simulated using the Mimics surgical simulator and included dissection of the superior articular process, dilation of the vertebral foramen, and placement of pedicle screws and a cage. ELIF anatomical measures were documented using a digitalized technique and subsequently validated on fresh cadavers.

Results

The use of the Mimics allowed for the vivid simulation of ELIF surgical procedures, while the cadaveric study proved the feasibility of this novel approach. ELIF had a relatively lateral access approach that was located 8–9 cm lateral to the median line with an access depth of approximately 9 cm through the intermuscular space. Dissection of the superior articular processes could fully expose the target intervertebral discs and facilitate a more inclined placement of the pedicle screws and cage with robust enhancement.

Conclusions

According to the computer-based simulation and cadaveric study, it is feasible to perform ELIF. Further research including biomechanical study is needed to prove ELIF has a superior ability to preserve the posterior tension bands of the spinal column, with similar effects on spinal decompression, fixation, and fusion, and if it can enhance post-fusion spinal stability and expedites postoperative recovery.  相似文献   

17.

Background

The incidence of spinal deformity in children with Prader-Willi syndrome (PWS) is high, with 86% of these patients found to have a significant structural scoliosis; however, there are very few case reports describing surgical treatment for this deformity.

Methods

The authors reviewed a case series consisting of 6 patients who underwent spine surgery for scoliosis. Children's mean age at index surgery was 12 years and 10 months (range, 10 to 15 yrs). Clinical evaluation revealed the typical phenotypic features of the PWS in all of the patients; 4 subjects had a karyotype confirmation of PWS. Major structural curves showed preoperative mean Cobb angles of 80.8° (range, 65° to 96°). Hybrid instrumentation with sublaminar wires, hooks and screws was used in the first 2 patients, while the remaining 4 were treated with titanium pedicle screw constructs.

Results

The mean clinical and radiological follow-up was 3 years and 10 months (range, 2 years to 9 years). Major complication rate was 50%. One patient who developed a major intraoperative complication (paraparesis) prevented spinal fusion to be obtained: the neurologic deficit resolved completely after instrumentation removal. Solid arthrodesis and deformity correction in both coronal and sagittal plane was, however, achieved in the other 5 cases and no significant curve progression was observed at follow-up. Another major short-term complication was encountered 3 months after surgery in a patient who experienced the detachment of a distally located rod and required correction through revision surgery and caudal extension by one level. Cervico-thoracic kyphosis was seen in 1 patient who did not require revision surgery.

Conclusions

Spine reconstructive surgery in patients with PWS is rare and highly demanding. The best method of reconstruction is posterior multilevel pedicle screw fixation. Moreover, even with modern techniques, the risk of complications is still high. These new techniques, however, have shown to improve the postoperative course by allowing for immediate mobilization without any brace or cast. The use of the growing rod techniques, requiring repeated surgeries, should be carefully evaluated in each single case.  相似文献   

18.

Background

Electromagnetic tracking is a relatively new technique that allows real time navigation in the absence of radiation. The aim of this study was to prove the feasibility of this technique for the treatment of posterior pelvic ring fractures and to compare the results with established image guided procedures.

Methods

Tests were performed in pelvic specimens (Sawbones®) with standardized sacral fractures (Type Denis I or II). A gel matrix simulated the operative approach and a cover was used to disable visual control. The electromagnetic setup was performed by using a custom made carbon reference plate and a prototype stainless steel K-wire with an integrated sensor coil. Four different test series were performed: Group OCT: Optical navigation using preoperative CT-scans; group O3D: Optical navigation using intraoperative 3-D-fluoroscopy; group Fluoro: Conventional 2-D-fluoroscopy; group EMT: Electromagnetic navigation combined with a preoperative Dyna-CT. Accuracy of screw placement was analyzed by standardized postoperative CT-scan for each specimen. Operation time and intraoperative radiation exposure for the surgeon was documented. All data was analyzed using SPSS (Version 20, 76 Chicago, IL, USA). Statistical significance was defined as p< 0.05.

Results

160 iliosacral screws were placed (40 per group). EMT resulted in a significantly higher incidence of optimal screw placement (EMT: 36/40) compared to the groups Fluoro (30/40; p< 0.05) and OCT (31/40; p< 0.05). Results between EMT and O3D were comparable (O3D: 37/40; n.s.). Also, the operation time was comparable between groups EMT and O3D (EMT 7.62 min vs. O3D 7.98 min; n.s.), while the surgical time was significantly shorter compared to the Fluoro group (10.69 min; p< 0.001) and the OCT group (13.3 min; p< 0.001).

Conclusion

Electromagnetic guided iliosacral screw placement is a feasible procedure. In our experimental setup, this method was associated with improved accuracy of screw placement and shorter operation time when compared with the conventional fluoroscopy guided technique and compared to the optical navigation using preoperative CT-scans. Further studies are necessary to rule out drawbacks of this technique regarding ferromagnetic objects.  相似文献   

19.

Background

Epidural anaesthesia is used extensively for cardiothoracic and vascular surgery in some centres, but not in others, with argument over the safety of the technique in patients who are usually extensively anticoagulated before, during, and after surgery. The principle concern is bleeding in the epidural space, leading to transient or persistent neurological problems.

Methods

We performed an extensive systematic review to find published cohorts of use of epidural catheters during vascular, cardiac, and thoracic surgery, using electronic searching, hand searching, and reference lists of retrieved articles.

Results

Twelve studies included 14,105 patients, of whom 5,026 (36%) had vascular surgery, 4,971 (35%) cardiac surgery, and 4,108 (29%) thoracic surgery. There were no cases of epidural haematoma, giving maximum risks following epidural anaesthesia in cardiac, thoracic, and vascular surgery of 1 in 1,700, 1 in 1,400 and 1 in 1,700 respectively. In all these surgery types combined the maximum expected rate would be 1 in 4,700. In all these patients combined there were eight cases of transient neurological injury, a rate of 1 in 1,700 (95% confidence interval 1 in 3,300 to 1 in 850). There were no cases of persistent neurological injury (maximum expected rate 1 in 4,600).

Conclusion

These estimates for cardiothoracic epidural anaesthesia should be the worst case. Limitations are inadequate denominators for different types of surgery in anticoagulated cardiothoracic or vascular patients more at risk of bleeding.  相似文献   

20.

Background and aims

Plant root placement is highly plastic in order to acquire patchily distributed nutrients and to ensure their survival, growth and reproduction. Considering the spatial extension of clonal organs, we selected two clonal plants (Leymus chinensis (Trin.) Tzvel. and Hierochloe glabra Trin.) to determine the spatio-temporal effects of environmental heterogeneity on belowground organs and newly-born ramets.

Methods

Small-scale and multi-patch heterogeneous environments were manipulated by creating four patches filled with different types of soil in a same pot. The four patches were composed of sandy soil, sandy loam, loam soil and humus soil, respectively. Ramet number, bud number, mean spacer length, rhizome length, and biomass allocation within each patch were measured to identify plant foraging responses.

Results

The preferential patch of L. chinensis was humus soil patch which was the highest in nutrient availability, whereas H. glabra preferred to place ramets in sandy loam and loam soil patches. When growing in homogeneous environments, both species randomly rooted their offspring ramets in the four compartments. In heterogeneous environments, foraging responses were detected in ramet placement, aboveground biomass and total rhizome length. However, there were no differences in bud number or belowground biomass among four types of patches in heterogeneous environments, which might suggest that there would be no inter-patch differences in seedling establishment in the next year.

Conclusions

Plants show selective allocation of offspring ramets to preferential patches in the presence of multi-patch environmental heterogeneity. Responses of H. glabra to multi-patch heterogeneity were faster than those of L. chinensis, demonstrating that the foraging patterns are species-specific. Clonal plants can rapidly respond to environmental heterogeneity, whereas foraging responses are potentially reversible over a longer temporal scale.  相似文献   