首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive, specific and stability-indicating high-performance liquid chromatographic (HPLC) assay, involving pre-column derivatization and solid-phase extraction (SPE), was developed and validated for the quantitation of busulfan (BU) in aqueous and plasma samples. The linearity of the assay was in the concentration ranges of 0.15–10 μg/ml and 0.15–3 μg/ml for aqueous and plasma samples, respectively. The within-day and between-day variations were 2.90 and 3.31%, respectively, for the aqueous samples, and 9.24 and 14.56%, respectively, for the plasma samples. The overall recovery, derivatization yield and SPE efficiency of BU from plasma samples were 82.03, 108.01 and 86.69%, respectively. Forced degraded samples, either in highly acidic, neutral or basic medium, produced no interfering peaks in the chromatogram. The reported assay requires only 0.2 ml of plasma for the analysis, and its sensitivity is 150 ng/ml by monitoring samples at a wavelength of 254 nm, sufficient to study the plasma pharmacokinetics of BU in rats after a clinically relevant oral dose. Moreover, the sensitivity of the assay can be significantly increased to 30 ng/ml by monitoring samples at a wavelength of 278 nm. The applications of the assay were demonstrated with BU solubility measurements in two aqueous systems and with plasma samples from a Sprague–Dawley rat for an in vivo pharmacokinetic study. In addition, the assay has been employed in the development of a patented intravenous formulation, and in evaluations of stability, preclinical pharmacokinetics in rats and dogs, and clinical phase I trial of the formulation. The assay is readily adaptable to clinical therapeutic drug monitoring.  相似文献   

2.
A selective and sensitive HPLC assay for the quantitative determination of a new antifilarial drug, 6,4′-bis-(2-imidazolinylhydrazone)-2-phenylimidazo[1,2-a]pyridine (CDR 101) is described. After extraction from plasma and blood, CDR 101 was analysed using a C18 Nucleosil ODS column (250×4.6 mm, 5 μm particle size) and mobile phase of acetonitrile-0.05 M ammonium acetate adjusted to pH 3.0, with UV detection at 318 nm. The mean recoveries of CDR 101 in plasma and blood over a concentration range of 25–500 ng/ml were 95.5±2.01% and 83.3±1.87%, respectively. The within-day and day-to-day coefficient of variations for plasma were 3.23-6.21% and 2.59-9.90%, respectively, those for blood were 2.59-5.92% and 2.89-6.82%, respectively. The minimum detectable concentration for CDR 101 was 1 ng/ml in plasma and 2.5 ng/ml in whole blood. This method was found to be suitable for clinical pharmacokinetic studies.  相似文献   

3.
A rapid and sensitive high-performance liquid chromatographic (HPLC) assay has been developed to allow determination of total (i.e. bound and unbound) and free (i.e. unbound) topotecan (TPT) in mouse plasma in the presence and absence of anti-TPT antibodies. The chromatographic analysis was carried out using reversed-phase isocratic elution with a Nova-Pak C18 column (3.9 mm x 150 mm, 4 microm) protected by a Nova-Pak C18 guard column (3.9 mm x 20 mm, 4 microm), where 10 mM KH(2)PO(4)-methanol-triethylamine (72:26:2 (v/v/v), pH 3.5) was used as the mobile phase. Topotecan was quantified with fluorescence detection using an excitation wavelength of 361 nm and an emission wavelength of 527 nm. The retention time for the internal standard, acridine, and TPT were 7.4 and 9.0 min, respectively. The lower limit of quantitation (LOQ) for TPT was determined as 0.02 ng in mouse plasma and mouse plasma ultrafiltrate, corresponding to a concentration of 1 ng/ml in 20 microl mouse plasma. The assay was shown to be linear over a concentration range of 1-500 ng/ml. The recoveries of free and total TPT from spiked mouse plasma were within 10% of theoretical values (assessed at 1, 20 and 500 ng/ml). The validated HPLC assay was applied to evaluate TPT pharmacokinetics following administration of TPT to Swiss Webster mice and to hyperimmunized and control BALB/c mice. The assay has been shown to be capable for measuring total and free TPT in mouse plasma with high sensitivity and will allow the testing of the effect of anti-TPT antibodies on the disposition of TPT.  相似文献   

4.
Bisantrene and mitoxantrone are two new anthracene derivatives which have shown significant antitumor activity against a wide variety of animal tumors and in human phase I and II clinical trials. We have developed a rapid, simple and sensitive sample cleanup procedure and high-performance liquid chromatographic (HPLC) assay for both drugs. This method uses a commercially available mini-cartridge with C18 reversed-phase packing to isolate the drugs from the biological matrix prior to HPLC. For both drugs the average recovery of the assay was 98 ± 6% with a coefficient of variation (C.V.) of less than 7%. Using this new method our assay sensitivity has improved to less than 10 ng/ml for bisantrene and 1 ng/ml for mitoxantrone, allowing us to document a prologned terminal phase plasma half-life for both bisantrene and mitoxantrone. Equilibrium dialysis studies showed that both drugs are highly protein bound. Mitoxantrone appears less stable in human plasma than bisantrene. Recoveries from plasma after a 24-h incubation at 25 and 37°C were 40 and 20% for mitoxantrone and 90 and 85% for bisantrene, respectively. Addition of ascorbic acid prior to incubation of mitoxantrone in human plasma at 37°C resulted in less than a 10% decrease in the latter's concentration over a 24-h period. To maintain sample integrity, all plasma samples should be fortified with ascorbic acid and kept frozen prior to analyses.  相似文献   

5.
The validation of an analytical method to quantify the antiangiogenic, (Z)-3-[2,4-dimethyl-5-(2-oxo-1,2-dihydro-indol-3-ylidenemethyl)-1H-pyrrol-3-yl]propionic acid (SU006668) for pharmacokinetic determination in a phase I clinical trial, is described. HPLC, with a gradient mobile phase and UV detection at 440 nm, was used. SU006668 was extracted from plasma by precipitation of proteins with acetonitrile. The assay was linear from 25 to 2000 ng/ml (r(2)=0.997); sensitive (limit of quantification 25 ng/ml), accurate (RE 2.6-11.9%) and reproducible (inter-batch precision C.V. 3.2%). Pharmacokinetic data for six patients are presented. They show linear pharmacokinetics with a low volume of distribution and induction at doses of 50, 100 and 200 mg/m(2).  相似文献   

6.
A reversed-phase high-performance liquid chromatographic method has been developed and validated for the quantification of the novel anticancer drug Ecteinascidin 743 in human plasma. The sample pretreatment of the plasma samples involved a solid-phase extraction (SPE) on cyano columns. Propyl-p-hydroxybenzoate was added after the sample pretreatment to correct for variability in injection volumes. The separation was performed on a Zorbax SB-C18 column (75×4.6 mm I.D., particle size 3.5 μm) with acetonitrile–25 mM phosphate buffer, pH 5.0 (70:30, v/v) as the mobile phase. The flow-rate was 1.0 ml/min and the eluent was monitored at 210 nm. The accuracies and precisions of the assay fall within ±15% for all quality control samples and within ±20% for the lower limit of quantitation, which was 1.0 ng/ml using 500 μl of plasma. The overall recovery of the sample pretreatment procedure for Ecteinascidin 743 was 87.0±5.9%. The drug was found to be stable in human plasma at −30°C for at least 2 months. At room temperature Ecteinascidin 743 was stable in human plasma for 5 h at most.  相似文献   

7.
A solid-phase extraction (SPE) procedure was developed for the quantification of nalbuphine in a small volume (500 μl) of human plasma with subsequent assay by high-performance liquid chromatography (HPLC) and electrochemical detection using 6-monoacetylmorphine as internal standard. Plasma was extracted using Bond Elute certified extraction columns (LCR: 10 ml, 130 mg) after conditioning with methanol and 0.2 M Tris buffer (pH 8). Elution was performed with a CH2Cl2-isopropanol-NH4OH (79:20:, v/v). The organic phase was evaporated to dryness and resuspended in HPLC mobile phase containing 2% isopropanol. Linearity was assessed over the 5–100 ng/ml concentration range and a straight line passing through the origin was obtained. Experiments with spiked plasma samples resulted in recoveries of 95±5.4% and 98±6.2% for nalbuphine and 6-monoacetylmorphine, respectively. The optimal pH conditions for the SPE were found at pH 8. The intra-day coefficients of variation (C.V.) for 5, 40, and 100 ng/ml were 5.3, 3.0 and 2.3% (n=8) and the inter-day C.V.s were 7.7, 3.2 and 3.5% (n=10), respectively. The detection limit for 500 μl plasma sample was 0.02 ng/ml and the limit of quantification 0.1 ng/ml (C.V.=12.4%). The ease of the proposed method of analysis, as well as its high accuracy and sensitivity allow its application to pharmacokinetic studies. A preliminary kinetic profile of nalbuphine after rectal administration in a pediatric patient is presented.  相似文献   

8.
On-line microdialysis coupled with microbore liquid chromatography was used to investigate the pharmacokinetics of chloramphenicol and its glucuronide in rat blood. A microdialysis probe was inserted into a jugular vein of male Sprague–Dawley rats. Chloramphenicol succinate (20 mg/kg, intravenously) was then administered via a femoral vein. Dialysates were automatically injected onto a LC system, via an on-line injector. Samples were eluted with a mobile phase containing acetonitrile-10 mM monochloroacetic acid (30:70, v/v, pH 3.0). The UV detector wavelength was set at 278 nm. The limit of quantitation for chloramphenicol was 10 ng/ml. The in vitro recoveries of chloramphenicol and chloramphenicol glucuronide at 500 ng/ml were 32.2±0.3% and 11.4±0.7%, respectively (n=6). Intra- and inter-assay accuracy and precision of the analyses were ≤10% in the range of 0.01 to 5.0 μg/ml.  相似文献   

9.
A method was developed for the assay of amitriptyline, amitriptyline-N-oxide, nortriptyline, desmethylnortriptyline and E (trans) and Z (cis) isomers of 10-hydroxyamitriptyline and of 10-hydroxynortriptyline in plasma and brain of animals, using high-performance liquid chromatography with ultraviolet detection (254 nm). Single extraction was performed at pH 10.5 from 0.25 ml of plasma or 1 ml of brain mixture. Chromatographic separations were achieved with a silica column and an aqueous methanol mobile phase containing ammonia. This procedure offers high sensitivity (8–10 ng/ml), high linearity (r > 0.99) and acceptable precision (coefficient of variation ≤ 13.3%). The method was used to determine levels of amitriptyline and its major metabolites in mice 30 min after a single intraperitoneal administration of amitriptyline (20 mg/kg).  相似文献   

10.
Irinotecan (CPT-11) is an anticancer agent widely employed in the treatment of colorectal carcinoma. A simple, rapid and sensitive high-performance liquid chromatographic method for the simultaneous determination of CPT-11 and its metabolite SN-38 in plasma, and their preliminary clinical pharmacokinetics are described. Both deproteinisation of plasma specimens (100 μl) and addition of the internal standard, camptothecin (CPT), are achieved by incorporating to samples 100 μl of a solution of CPT (1 μg/ml) in acetonitrile–1 mM orthophosphoric acid (90:10); 200 μl of this acidified acetonitrile solution, drug-free, is also added to accomplish complete deproteinisation: this procedure reduces sample preparation time to a minimum. After deproteinisation, samples are treated with potassium dihydrogenphosphate (0.1 M) and injected into a Nucleosil C18 (5 μm, 250×4.0 mm) column. Mobile phase consists of potassium dihydrogenphosphate (0.1 M)–acetonitrile (67:33), at a flow-rate of 1 ml/min. CPT-11, SN-38 and CPT are detected by fluorescence with excitation wavelength set at 228 nm and emission wavelengths of CPT-11, SN-38 and CPT fixed, respectively, at 450, 543 and 433 nm. The limits of quantitation for CPT-11 and SN-38 are 1.0 and 0.5 ng/ml, respectively. This method shows good precision: the within day relative standard deviation (RSD) for CPT-11 (1–10 000 ng/ml) is 5.17% (range 2.15–8.27%) and for SN-38 (0.5–400 ng/ml) is 4.33% (1.32–7.78%); the between-day RSDs for CPT-11 and SN-38, in the previously described ranges, are 6.82% (5.03–10.8%) and 4.94% (2.09–9.30%), respectively. Using this assay, plasma pharmacokinetics of CPT-11, SN-38 and its glucuronidated form, SN-38G, have been determined in one patient receiving 200 mg/m2 of CPT-11 as a 90 min intravenous infusion. The peak plasma concentration of CPT-11 at the end of the infusion is 3800 ng/ml. Plasma decay is biphasic with a terminal half-life of 11.6 h. The volume of distribution at steady state (Vss) is 203 l/m2, and the total body clearance (Cl) is 14.8 l/h·m2. The maximum concentrations of SN-38 and SN-38G reach 28.9 and 151 ng/ml, respectively.  相似文献   

11.
The renin inhibitor Ro 42-5892 has been found to be very potent, thereby necessitating a sensitive assay method for the evaluation of its pharmacokinetics in man. We report here the development of a very sensitive and selective HPLC assay for the analysis of this compound in human plasma. Ro 42-5892 was extracted from plasma with dichloromethane, derivatized with 2,4-dinitrofluorobenzene and then chromatographed on a Novapak C18 column (150 × 3.9 mm I.D.) with acetic acid buffer (pH 7)-acetonitrile (100:85). Detection was performed by irradiation at 254 nm, followed by electrochemical oxidation at 550 mV. The extraction recovery of Ro 92-5 from human plasma (mean 102%) was quantitative. With this method a limit of quantitation of 0.3 ng/ml was achieved. The assay was linear up to 5 ng/ml, had acceptable inter-assay precision (12.2%) and accuracy (9.3%) and was successfully tested for selectivity. This assay was successfully applied to over 250 samples from a pharmacokinetic study in hypertensive patients.  相似文献   

12.
A method is described for the determination of pyronaridine in plasma using high-performance liquid chromatography with fluorescence detection. The method involves liquid-liquid extraction with phosphate buffer (pH 6.0, 0.05 M) and diethyl ether-hexane (70:30%, v/v) and chromatographic separation on a C18 column (Nucleosil, 250 × 4.6 mm I.D., 5 μm particle size) with acetonitrile-0.05 M phosphate buffer pH 6.0 (60:40%, v/v) as the mobile phase (1 ml/min) and detection by fluorescence (λex = 267 nm, λem = 443 nm). The detector response is linear up to 1000 ng and the overall recoveries pyronaridine and quinine were 90.0 and 60.3%, respectively. The assay procedure was adequately sensitive to measure 10 ng/ml pyronaridine in plasma samples with acceptable precision (< 15% C.V.). The method was found to be suitable for use in clinical pharmacological studies.  相似文献   

13.
We have established a highly sensitive high-performance liquid chromatographic method for the determination of an anticancer drug, UCN-01, in human plasma or urine. Using a fluorescence detector set at an excitation wavelength of 310 nm and emission monitored at 410 nm, there was a good linearity for UCN-01 in human plasma (r=0.999) or urine (r=0.999) at concentrations ranging from 0.2 to 100 ng/ml or 1 to 400 ng/ml, respectively. For intra-day assay, in plasma samples, the precision and accuracy were 1.8% to 5.6% and −10.0% to 5.2%, respectively. For inter-day assay, the precision and accuracy were 2.0% to 18.2% and 2.4% to 10.0%, respectively. In urine samples, the intra- and inter-day precision and accuracy were within 3.9% and ±2.7%, respectively. The lower limit of quantification (LLOQ) was set at 0.2 ng/ml in plasma and 1 ng/ml in urine. UCN-01 in plasma samples was stable up to two weeks at −80°C and also up to four weeks in urine samples. This method could be very useful for studying the human pharmacokinetics of UCN-01.  相似文献   

14.
The development of a new enzyme immunoassay for neuropeptide Y (NPY) is reported. Two monoclonal antibodies directed against distinct epitopes of NPY are used, one as a capture antibody (NPY02) and the other one as an indicator antibody (NPY05), this latter antibody being labeled with alkaline phosphatase. The assay calibration curve was performed over concentrations of 1 to 250 pM in a NPY-free plasma. The intra-assay coefficient of variation (CV) ranged from 0.025 to 11.9%, whereas the interassay CV was comprised between 5 and 12%. The limit of detection of this assay was 1 pM (100 amol/well). Neuropeptide Y levels are related to sampling conditions; basal concentrations of NPY with low SEM are found when less than 1.2 ml of blood is taken in EDTA tubes, the sample is centrifuged at 4°C, and immediately frozen. Unanesthetized spontaneously hypertensive rats exhibited higher NPY plasma concentrations than normotensive Wistar-Kyoto controls (53 ± 7 pM and 25 ± 2 pM, respectively, mean ± SEM, p < 0.01). Plasma NPY levels are similar in 16- and 36-week-old animals. In conclusion, this technique makes it possible to assay a large number of samples within 24 h without requiring radioactivity.  相似文献   

15.
A sensitive high-performance liquid chromatographic assay for the specific determination of indomethacin at concentrations down to 20 ng/ml in human plasma is described.

This method has been applied to investigate the disappearance of indomethacin from plasma of ten subjects following the intake of two formulations (Indocid® and generic form). An initial half-life of 1.32 ± 0.44 h−1 was found which is in good agreement with other findings, but the terminal phase was much longer (13.6 ± 6.9 h−1) than previously reported. There is no difference between the two galenic forms (p <0.001).  相似文献   


16.
A sensitive analytical procedure for bupivacaine dosing in plasma samples by reversed-phase high-performance liquid chromatography is described. After a two-step extraction, the analysis was performed using a C18 column and a mobile phase of 0.01 M sodium dihydrogen-phosphate (pH 2.1)—acetonitrile (80:20, v/v). The extraction yield of bupivacaine from plasma was 73.5 ± 5.1% (mean ± S.D., n = 10). The within-day and between-day reproducibilities at a concentration of 100 ng/ml were 2.1% and 5.6%, respectively (n = 10). Calibration curves were linear (r2 = 0.9996) between 5 and 1000 ng/ml. The limit of detection, defined by a signal-to-noise ratio of 3:1, was 2 ng/ml. The accuracy at a concentration of 100 ng/ml was 2.3%. This method could be applied to the plasma analysis of seven other local anaesthetics (articaine, etidocaine, lidocaine, mepivacaine, pramocaine, procaine and tetracaine). The procedure was used in bioavailability studies of bupivacaine-loaded poly( -lactide) (i.e. PLA) and poly( -lactide-co-glycolide) (i.e. PLGA) microspheres after subcutaneous and intrathecal administrations in rabbits.  相似文献   

17.
High-performance liquid chromatographic assay for cefepime in serum   总被引:6,自引:0,他引:6  
A simple, rapid, specific and sensitive high-performance liquid chromatographic method was developed for the determination of cefepime 1-[[6R, 7R)-7-[2-(2-amino-4-thiazolyl)glyoxylamido]-2-carboxy-8-oxo-5-thia-1-azabicyclo-[4.2.0] oct-2-en-3-yl]methyl]-1-methylpyrrolidinium hydroxide, inner salt, 72-(Z)-(O-methyloxime) in human serum. Separation was achieved on a reversed-phase Ultrasphere XL-ODS column (75×4.6 mm I.D.). The mobile phase was 7% acetonitrile in 20 mM ammonium acetate (pH 4). Cefepime eluted in the range of 1.8–2.2 min. Detection was by UV absorbance at 254 nm. The lower limit of quantitation of cefepime in plasma was 0.5 μg/ml. The average absolute recovery was 106.2±2.1%. The linear range was from 0.1 to 50 μg/ml, with a correlation coefficient greater than 0.999. The within-day C.V.s for human samples were 4.9 and 2.3% for 1 and 50 μg/ml, respectively. The between-day C.V.s for human serum samples were 14.5, 7.4 and 6.7 for 1, 25 and 50 μg/ml, respectively. Cefepime was found to be unstable in serum at room temperature. For delayed assay, samples must be stored at −80°C.  相似文献   

18.
We developed a sensitive and selective method for determining levels of sultopride, a neuroleptic drug of the substituted benzamide, in human plasma using high-performance liquid chromatography (HPLC) combined with UV detection and particle beam mass spectrometry (PBMS). Sutopride was extracted with tert.-butylmethyl ether using a salting-out technique. Tiapride served as an internal standard (I.S.). Sutopride and I.S. were separated by HPLC on a silica column with a mobile phase of acetonitrile-0.1 M ammonium acetate (94:6, v/v). The calibration curves were linear over the concentration range from 5 to 1000 ng/ml by HPLC with UV detection and from 10 to 1000 ng/ml with PBMS detection. The limit of quantitation was 5 ng/ml with UV detection and 10 ng/ml with PBMS detection. The absolute recovery was 92% and the within-day coefficients of variation were 2.9–7.1% at plasma concentrations from 50 to 500 ng/ml, determined by HPLC with UV detection. Using this method, we measured the plasma concentrations of sultopride with replicate analyses in four hospitalized patients and steady-state plasma levels were determined to be 161.6±30.8, 321.1±93.7, 726.5±143.1 and 1273.6±211.2 ng/ml, respectively.  相似文献   

19.
A simple, highly sensitive and specific LC-MS-MS assay was developed for the determination of CP-122,721 (I) in rat and human plasma. I and a structural analog, CP-129,943 (II, internal standard), were extracted from plasma with methyl tert.-butyl ether (MTBE). The dried MTBE extracts were reconstituted and analyzed using a narrow-bore (2.1 mm I.D.) YMC basic HPLC column and a mobile phase of acetonitrile-20 mM ammonium acetate, pH 5 (50:50, v/v). Column effluents were monitored by ionspray tandem mass spectrometry. Multiple reaction monitoring (MRM) using the parent to product ion combinations of m/z 381 → 205 and 395 → 219 was used to quantitate I and II, respectively. The assay exhibited a linear dynamic range of 0.2–100 ng/ml. Absolute recoveries from plasma were above 80% for both I and II. The precision and accuracy values for the method were within ±3 and ±9%, respectively. Sample analysis times were less than 5 min from one injection to the next. The assay has proved to be applicable to the pharmacokinetic study of I in rats.  相似文献   

20.
For the assay of the antidepressant compound mianserin hydrochloride (Org GB 94) in human plasma, a mass fragmentographic method, using the deuterated analogue as internal standard and a high-performance liquid chromatographie sample clean-up procedure has been developed. The assay specifications obtained are a lower limit for reliable measurements of 1 ng/ml, an accuracy of ca. 0.01 ng/ml, a precision of 6–7% and a capacity of about 60 samples per day. The applicability of the assay method is illustrated by measurements of single-dose and steady-state plasma levels in clinical experiments, demonstrating the possibility of monitoring plasma levels during at least 24 h after a single dose of 15 mg of Org GB 94. The mean steady-state plasma levels after a daily dose of 3 × 20 mg of Org GB 94 appeared to be remarkably constant with time: 38, 36 and 34 ng/ml after 2, 4 and 6 weeks of treatment of 18 depressed patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号