共查询到20条相似文献,搜索用时 46 毫秒
1.
2.
3.
Christelle Robert Pablo Fuentes-Utrilla Karen Troup Julia Loecherbach Frances Turner Richard Talbot Alan L Archibald Alan Mileham Nader Deeb David A Hume Mick Watson 《BMC genomics》2014,15(1)
Background
The domestic pig (Sus scrofa) is both an important livestock species and a model for biomedical research. Exome sequencing has accelerated identification of protein-coding variants underlying phenotypic traits in human and mouse. We aimed to develop and validate a similar resource for the pig.Results
We developed probe sets to capture pig exonic sequences based upon the current Ensembl pig gene annotation supplemented with mapped expressed sequence tags (ESTs) and demonstrated proof-of-principle capture and sequencing of the pig exome in 96 pigs, encompassing 24 capture experiments. For most of the samples at least 10x sequence coverage was achieved for more than 90% of the target bases. Bioinformatic analysis of the data revealed over 236,000 high confidence predicted SNPs and over 28,000 predicted indels.Conclusions
We have achieved coverage statistics similar to those seen with commercially available human and mouse exome kits. Exome capture in pigs provides a tool to identify coding region variation associated with production traits, including loss of function mutations which may explain embryonic and neonatal losses, and to improve genomic assemblies in the vicinity of protein coding genes in the pig.Electronic supplementary material
The online version of this article (doi:10.1186/1471-2164-15-550) contains supplementary material, which is available to authorized users. 相似文献4.
Funda Orkunoglu-Suer Arthur F Harralson David Frankfurter Paul Gindoff Travis J O’Brien 《BMC genomics》2015,16(1)
Background
One of the most significant issues surrounding next generation sequencing is the cost and the difficulty assembling short read lengths. Targeted capture enrichment of longer fragments using single molecule sequencing (SMS) is expected to improve both sequence assembly and base-call accuracy but, at present, there are very few examples of successful application of these technologic advances in translational research and clinical testing. We developed a targeted single molecule sequencing (T-SMS) panel for genes implicated in ovarian response to controlled ovarian hyperstimulation (COH) for infertility.Results
Target enrichment was carried out using droplet-base multiplex polymerase chain reaction (PCR) technology (RainDance®) designed to yield amplicons averaging 1 kb fragment size from candidate 44 loci (99.8% unique base-pair coverage). The total targeted sequence was 3.18 Mb per sample. SMS was carried out using single molecule, real-time DNA sequencing (SMRT® Pacific Biosciences®), average raw read length = 1178 nucleotides, 5% of the amplicons >6000 nucleotides). After filtering with circular consensus (CCS) reads, the mean read length was 3200 nucleotides (97% CCS accuracy). Primary data analyses, alignment and filtering utilized the Pacific Biosciences® SMRT portal. Secondary analysis was conducted using the Genome Analysis Toolkit for SNP discovery l and wANNOVAR for functional analysis of variants. Filtered functional variants 18 of 19 (94.7%) were further confirmed using conventional Sanger sequencing. CCS reads were able to accurately detect zygosity. Coverage within GC rich regions (i.e.VEGFR; 72% GC rich) was achieved by capturing long genomic DNA (gDNA) fragments and reading into regions that flank the capture regions. As proof of concept, a non-synonymous LHCGR variant captured in two severe OHSS cases, and verified by conventional sequencing.Conclusions
Combining emulsion PCR-generated 1 kb amplicons and SMRT DNA sequencing permitted greater depth of coverage for T-SMS and facilitated easier sequence assembly. To the best of our knowledge, this is the first report combining emulsion PCR and T-SMS for long reads using human DNA samples, and NGS panel designed for biomarker discovery in OHSS.Electronic supplementary material
The online version of this article (doi:10.1186/s12864-015-1451-2) contains supplementary material, which is available to authorized users. 相似文献5.
Distinguishing low frequency mutations from RT-PCR and sequence errors in viral deep sequencing data
Richard J Orton Caroline F Wright Marco J Morelli David J King David J Paton Donald P King Daniel T Haydon 《BMC genomics》2015,16(1)
Background
RNA viruses have high mutation rates and exist within their hosts as large, complex and heterogeneous populations, comprising a spectrum of related but non-identical genome sequences. Next generation sequencing is revolutionising the study of viral populations by enabling the ultra deep sequencing of their genomes, and the subsequent identification of the full spectrum of variants within the population. Identification of low frequency variants is important for our understanding of mutational dynamics, disease progression, immune pressure, and for the detection of drug resistant or pathogenic mutations. However, the current challenge is to accurately model the errors in the sequence data and distinguish real viral variants, particularly those that exist at low frequency, from errors introduced during sequencing and sample processing, which can both be substantial.Results
We have created a novel set of laboratory control samples that are derived from a plasmid containing a full-length viral genome with extremely limited diversity in the starting population. One sample was sequenced without PCR amplification whilst the other samples were subjected to increasing amounts of RT and PCR amplification prior to ultra-deep sequencing. This enabled the level of error introduced by the RT and PCR processes to be assessed and minimum frequency thresholds to be set for true viral variant identification. We developed a genome-scale computational model of the sample processing and NGS calling process to gain a detailed understanding of the errors at each step, which predicted that RT and PCR errors are more likely to occur at some genomic sites than others. The model can also be used to investigate whether the number of observed mutations at a given site of interest is greater than would be expected from processing errors alone in any NGS data set. After providing basic sample processing information and the site’s coverage and quality scores, the model utilises the fitted RT-PCR error distributions to simulate the number of mutations that would be observed from processing errors alone.Conclusions
These data sets and models provide an effective means of separating true viral mutations from those erroneously introduced during sample processing and sequencing.Electronic supplementary material
The online version of this article (doi:10.1186/s12864-015-1456-x) contains supplementary material, which is available to authorized users. 相似文献6.
Guoqiang Zhang Jianfeng Wang Jin Yang Wenjie Li Yutian Deng Jing Li Jun Huang Songnian Hu Bing Zhang 《BMC genomics》2015,16(1)
Background
To promote the clinical application of next-generation sequencing, it is important to obtain accurate and consistent variants of target genomic regions at low cost. Ion Proton, the latest updated semiconductor-based sequencing instrument from Life Technologies, is designed to provide investigators with an inexpensive platform for human whole exome sequencing that achieves a rapid turnaround time. However, few studies have comprehensively compared and evaluated the accuracy of variant calling between Ion Proton and Illumina sequencing platforms such as HiSeq 2000, which is the most popular sequencing platform for the human genome. The Ion Proton sequencer combined with the Ion TargetSeq™ Exome Enrichment Kit together make up TargetSeq-Proton, whereas SureSelect-Hiseq is based on the Agilent SureSelect Human All Exon v4 Kit and the HiSeq 2000 sequencer.Results
Here, we sequenced exonic DNA from four human blood samples using both TargetSeq-Proton and SureSelect-HiSeq. We then called variants in the exonic regions that overlapped between the two exome capture kits (33.6 Mb). The rates of shared variant loci called by two sequencing platforms were from 68.0 to 75.3 % in four samples, whereas the concordance of co-detected variant loci reached 99 %. Sanger sequencing validation revealed that the validated rate of concordant single nucleotide polymorphisms (SNPs) (91.5 %) was higher than the SNPs specific to TargetSeq-Proton (60.0 %) or specific to SureSelect-HiSeq (88.3 %). With regard to 1-bp small insertions and deletions (InDels), the Sanger sequencing validated rates of concordant variants (100.0 %) and SureSelect-HiSeq-specific (89.6 %) were higher than those of TargetSeq-Proton-specific (15.8 %).Conclusions
In the sequencing of exonic regions, a combination of using of two sequencing strategies (SureSelect-HiSeq and TargetSeq-Proton) increased the variant calling specificity for concordant variant loci and the sensitivity for variant loci called by any one platform. However, for the sequencing of platform-specific variants, the accuracy of variant calling by HiSeq 2000 was higher than that of Ion Proton, specifically for the InDel detection. Moreover, the variant calling software also influences the detection of SNPs and, specifically, InDels in Ion Proton exome sequencing.Electronic supplementary material
The online version of this article (doi:10.1186/s12864-015-1796-6) contains supplementary material, which is available to authorized users. 相似文献7.
Min Wang Christine R Beck Adam C English Qingchang Meng Christian Buhay Yi Han Harsha V Doddapaneni Fuli Yu Eric Boerwinkle James R Lupski Donna M Muzny Richard A Gibbs 《BMC genomics》2015,16(1)
Background
Generation of long (>5 Kb) DNA sequencing reads provides an approach for interrogation of complex regions in the human genome. Currently, large-insert whole genome sequencing (WGS) technologies from Pacific Biosciences (PacBio) enable analysis of chromosomal structural variations (SVs), but the cost to achieve the required sequence coverage across the entire human genome is high.Results
We developed a method (termed PacBio-LITS) that combines oligonucleotide-based DNA target-capture enrichment technologies with PacBio large-insert library preparation to facilitate SV studies at specific chromosomal regions. PacBio-LITS provides deep sequence coverage at the specified sites at substantially reduced cost compared with PacBio WGS. The efficacy of PacBio-LITS is illustrated by delineating the breakpoint junctions of low copy repeat (LCR)-associated complex structural rearrangements on chr17p11.2 in patients diagnosed with Potocki–Lupski syndrome (PTLS; MIM#610883). We successfully identified previously determined breakpoint junctions in three PTLS cases, and also were able to discover novel junctions in repetitive sequences, including LCR-mediated breakpoints. The new information has enabled us to propose mechanisms for formation of these structural variants.Conclusions
The new method leverages the cost efficiency of targeted capture-sequencing as well as the mappability and scaffolding capabilities of long sequencing reads generated by the PacBio platform. It is therefore suitable for studying complex SVs, especially those involving LCRs, inversions, and the generation of chimeric Alu elements at the breakpoints. Other genomic research applications, such as haplotype phasing and small insertion and deletion validation could also benefit from this technology.Electronic supplementary material
The online version of this article (doi:10.1186/s12864-015-1370-2) contains supplementary material, which is available to authorized users. 相似文献8.
Background
Recent advances in deep digital sequencing have unveiled an unprecedented degree of clonal heterogeneity within a single tumor DNA sample. Resolving such heterogeneity depends on accurate estimation of fractions of alleles that harbor somatic mutations. Unlike substitutions or small indels, structural variants such as deletions, duplications, inversions and translocations involve segments of DNAs and are potentially more accurate for allele fraction estimations. However, no systematic method exists that can support such analysis.Results
In this paper, we present a novel maximum-likelihood method that estimates allele fractions of structural variants integratively from various forms of alignment signals. We develop a tool, BreakDown, to estimate the allele fractions of most structural variants including medium size (from 1 kilobase to 1 megabase) deletions and duplications, and balanced inversions and translocations.Conclusions
Evaluation based on both simulated and real data indicates that our method systematically enables structural variants for clonal heterogeneity analysis and can greatly enhance the characterization of genomically instable tumors.Electronic supplementary material
The online version of this article (doi:10.1186/1471-2105-15-299) contains supplementary material, which is available to authorized users. 相似文献9.
Background
Human leukocyte antigen (HLA) genes are critical genes involved in important biomedical aspects, including organ transplantation, autoimmune diseases and infectious diseases. The gene family contains the most polymorphic genes in humans and the difference between two alleles is only a single base pair substitution in many cases. The next generation sequencing (NGS) technologies could be used for high throughput HLA typing but in silico methods are still needed to correctly assign the alleles of a sample. Computer scientists have developed such methods for various NGS platforms, such as Illumina, Roche 454 and Ion Torrent, based on the characteristics of the reads they generate. However, the method for PacBio reads was less addressed, probably owing to its high error rates. The PacBio system has the longest read length among available NGS platforms, and therefore is the only platform capable of having exon 2 and exon 3 of HLA genes on the same read to unequivocally solve the ambiguity problem caused by the “phasing” issue.Results
We proposed a new method BayesTyping1 to assign HLA alleles for PacBio circular consensus sequencing reads using Bayes’ theorem. The method was applied to simulated data of the three loci HLA-A, HLA-B and HLA-DRB1. The experimental results showed its capability to tolerate the disturbance of sequencing errors and external noise reads.Conclusions
The BayesTyping1 method could overcome the problems of HLA typing using PacBio reads, which mostly arise from sequencing errors of PacBio reads and the divergence of HLA genes, to some extent.Electronic supplementary material
The online version of this article (doi:10.1186/1471-2105-15-296) contains supplementary material, which is available to authorized users. 相似文献10.
Background
Patient-derived tumor xenografts in mice are widely used in cancer research and have become important in developing personalized therapies. When these xenografts are subject to DNA sequencing, the samples could contain various amounts of mouse DNA. It has been unclear how the mouse reads would affect data analyses. We conducted comprehensive simulations to compare three alignment strategies at different mutation rates, read lengths, sequencing error rates, human-mouse mixing ratios and sequenced regions. We also sequenced a nasopharyngeal carcinoma xenograft and a cell line to test how the strategies work on real data.Results
We found the "filtering" and "combined reference" strategies performed better than aligning reads directly to human reference in terms of alignment and variant calling accuracies. The combined reference strategy was particularly good at reducing false negative variants calls without significantly increasing the false positive rate. In some scenarios the performance gain of these two special handling strategies was too small for special handling to be cost-effective, but it was found crucial when false non-synonymous SNVs should be minimized, especially in exome sequencing.Conclusions
Our study systematically analyzes the effects of mouse contamination in the sequencing data of human-in-mouse xenografts. Our findings provide information for designing data analysis pipelines for these data.Electronic supplementary material
The online version of this article (doi:10.1186/1471-2164-15-1172) contains supplementary material, which is available to authorized users. 相似文献11.
Giovanna Carpi Katharine S. Walter Stephen J. Bent Anne Gatewood Hoen Maria Diuk-Wasser Adalgisa Caccone 《BMC genomics》2015,16(1)
Background
Rapid and accurate retrieval of whole genome sequences of human pathogens from disease vectors or animal reservoirs will enable fine-resolution studies of pathogen epidemiological and evolutionary dynamics. However, next generation sequencing technologies have not yet been fully harnessed for the study of vector-borne and zoonotic pathogens, due to the difficulty of obtaining high-quality pathogen sequence data directly from field specimens with a high ratio of host to pathogen DNA.Results
We addressed this challenge by using custom probes for multiplexed hybrid capture to enrich for and sequence 30 Borrelia burgdorferi genomes from field samples of its arthropod vector. Hybrid capture enabled sequencing of nearly the complete genome (~99.5 %) of the Borrelia burgdorferi pathogen with 132-fold coverage, and identification of up to 12,291 single nucleotide polymorphisms per genome.Conclusions
The proprosed culture-independent method enables efficient whole genome capture and sequencing of pathogens directly from arthropod vectors, thus making population genomic study of vector-borne and zoonotic infectious diseases economically feasible and scalable. Furthermore, given the similarities of invertebrate field specimens to other mixed DNA templates characterized by a high ratio of host to pathogen DNA, we discuss the potential applicabilty of hybrid capture for genomic study across diverse study systems.Electronic supplementary material
The online version of this article (doi:10.1186/s12864-015-1634-x) contains supplementary material, which is available to authorized users. 相似文献12.
Background
Like other structural variants, transposable element insertions can be highly polymorphic across individuals. Their functional impact, however, remains poorly understood. Current genome-wide approaches for genotyping insertion-site polymorphisms based on targeted or whole-genome sequencing remain very expensive and can lack accuracy, hence new large-scale genotyping methods are needed.Results
We describe a high-throughput method for genotyping transposable element insertions and other types of structural variants that can be assayed by breakpoint PCR. The method relies on next-generation sequencing of multiplex, site-specific PCR amplification products and read count-based genotype calls. We show that this method is flexible, efficient (it does not require rounds of optimization), cost-effective and highly accurate.Conclusions
This method can benefit a wide range of applications from the routine genotyping of animal and plant populations to the functional study of structural variants in humans.Electronic supplementary material
The online version of this article (doi:10.1186/s12864-015-1700-4) contains supplementary material, which is available to authorized users. 相似文献13.
14.
15.
Chandra Sekhar Reddy Chilamakuri Susanne Lorenz Mohammed-Amin Madoui Daniel Vodák Jinchang Sun Eivind Hovig Ola Myklebost Leonardo A Meza-Zepeda 《BMC genomics》2014,15(1)
Background
Recent developments in deep (next-generation) sequencing technologies are significantly impacting medical research. The global analysis of protein coding regions in genomes of interest by whole exome sequencing is a widely used application. Many technologies for exome capture are commercially available; here we compare the performance of four of them: NimbleGen’s SeqCap EZ v3.0, Agilent’s SureSelect v4.0, Illumina’s TruSeq Exome, and Illumina’s Nextera Exome, all applied to the same human tumor DNA sample.Results
Each capture technology was evaluated for its coverage of different exome databases, target coverage efficiency, GC bias, sensitivity in single nucleotide variant detection, sensitivity in small indel detection, and technical reproducibility. In general, all technologies performed well; however, our data demonstrated small, but consistent differences between the four capture technologies. Illumina technologies cover more bases in coding and untranslated regions. Furthermore, whereas most of the technologies provide reduced coverage in regions with low or high GC content, the Nextera technology tends to bias towards target regions with high GC content.Conclusions
We show key differences in performance between the four technologies. Our data should help researchers who are planning exome sequencing to select appropriate exome capture technology for their particular application.Electronic supplementary material
The online version of this article (doi:10.1186/1471-2164-15-449) contains supplementary material, which is available to authorized users. 相似文献16.
Eva C Berglund Carl M?rten Lindqvist Shahina Hayat Elin ?vern?s Niklas Henriksson Jessica Nordlund Per Wahlberg Erik Forestier Gudmar L?nnerholm Ann-Christine Syv?nen 《BMC genomics》2013,14(1)
Background
Target enrichment and resequencing is a widely used approach for identification of cancer genes and genetic variants associated with diseases. Although cost effective compared to whole genome sequencing, analysis of many samples constitutes a significant cost, which could be reduced by pooling samples before capture. Another limitation to the number of cancer samples that can be analyzed is often the amount of available tumor DNA. We evaluated the performance of whole genome amplified DNA and the power to detect subclonal somatic single nucleotide variants in non-indexed pools of cancer samples using the HaloPlex technology for target enrichment and next generation sequencing.Results
We captured a set of 1528 putative somatic single nucleotide variants and germline SNPs, which were identified by whole genome sequencing, with the HaloPlex technology and sequenced to a depth of 792–1752. We found that the allele fractions of the analyzed variants are well preserved during whole genome amplification and that capture specificity or variant calling is not affected. We detected a large majority of the known single nucleotide variants present uniquely in one sample with allele fractions as low as 0.1 in non-indexed pools of up to ten samples. We also identified and experimentally validated six novel variants in the samples included in the pools.Conclusion
Our work demonstrates that whole genome amplified DNA can be used for target enrichment equally well as genomic DNA and that accurate variant detection is possible in non-indexed pools of cancer samples. These findings show that analysis of a large number of samples is feasible at low cost, even when only small amounts of DNA is available, and thereby significantly increases the chances of indentifying recurrent mutations in cancer samples.Electronic supplementary material
The online version of this article (doi:10.1186/1471-2164-14-856) contains supplementary material, which is available to authorized users. 相似文献17.
Chang-Ki Yoon Nayoung K. D. Kim Je-Gun Joung Joo Young Shin Jung Hyun Park Hye-Hyun Eum Hae-ock Lee Woong-Yang Park Hyeong Gon Yu 《BMC genomics》2015,16(1)
Background
Identification of the causative genes of retinitis pigmentosa (RP) is important for the clinical care of patients with RP. However, a comprehensive genetic study has not been performed in Korean RP patients. Moreover, the genetic heterogeneity found in sensorineural genetic disorders makes identification of pathogenic mutations challenging. Therefore, high throughput genetic testing using massively parallel sequencing is needed.Results
Sixty-two Korean patients with nonsyndromic RP (46 patients from 18 families and 16 simplex cases) who consented to molecular genetic testing were recruited in this study and targeted exome sequencing was applied on 53 RP-related genes. Causal variants were characterised by selecting exonic and splicing variants, selecting variants with low allele frequency (below 1 %), and discarding the remaining variants with quality below 20. The variants were additionally confirmed by an inheritance pattern and cosegregation test of the families, and the rest of the variants were prioritised using in-silico prediction tools. Finally, causal variants were detected from 10 of 18 familial cases (55.5 %) and 7 of 16 simplex cases (43.7 %) in total. Novel variants were detected in 13 of 20 (65 %) candidate variants. Compound heterozygous variants were found in four of 7 simplex cases.Conclusion
Panel-based targeted re-sequencing can be used as an effective molecular diagnostic tool for RP.Electronic supplementary material
The online version of this article (doi:10.1186/s12864-015-1723-x) contains supplementary material, which is available to authorized users. 相似文献18.
Background
The popularity of new sequencing technologies has led to an explosion of possible applications, including new approaches in biodiversity studies. However each of these sequencing technologies suffers from sequencing errors originating from different factors. For 16S rRNA metagenomics studies, the 454 pyrosequencing technology is one of the most frequently used platforms, but sequencing errors still lead to important data analysis issues (e.g. in clustering in taxonomic units and biodiversity estimation). Moreover, retaining a higher portion of the sequencing data by preserving as much of the read length as possible while maintaining the error rate within an acceptable range, will have important consequences at the level of taxonomic precision.Results
The new error correction algorithm proposed in this work - NoDe (Noise Detector) - is trained to identify those positions in 454 sequencing reads that are likely to have an error, and subsequently clusters those error-prone reads with correct reads resulting in error-free representative read. A benchmarking study with other denoising algorithms shows that NoDe can detect up to 75% more errors in a large scale mock community dataset, and this with a low computational cost compared to the second best algorithm considered in this study. The positive effect of NoDe in 16S rRNA studies was confirmed by the beneficial effect on the precision of the clustering of pyrosequencing reads in operational taxonomic units.Conclusions
NoDe was shown to be a computational efficient denoising algorithm for pyrosequencing reads, producing the lowest error rates in an extensive benchmarking study with other denoising algorithms.Electronic supplementary material
The online version of this article (doi:10.1186/s12859-015-0520-5) contains supplementary material, which is available to authorized users. 相似文献19.
Thomas Kuilman Arno Velds Kristel Kemper Marco Ranzani Lorenzo Bombardelli Marlous Hoogstraat Ekaterina Nevedomskaya Guotai Xu Julian de Ruiter Martijn P Lolkema Bauke Ylstra Jos Jonkers Sven Rottenberg Lodewyk F Wessels David J Adams Daniel S Peeper Oscar Krijgsman 《Genome biology》2015,16(1)
Current methods for detection of copy number variants (CNV) and aberrations (CNA) from targeted sequencing data are based on the depth of coverage of captured exons. Accurate CNA determination is complicated by uneven genomic distribution and non-uniform capture efficiency of targeted exons. Here we present CopywriteR, which eludes these problems by exploiting ‘off-target’ sequence reads. CopywriteR allows for extracting uniformly distributed copy number information, can be used without reference, and can be applied to sequencing data obtained from various techniques including chromatin immunoprecipitation and target enrichment on small gene panels. CopywriteR outperforms existing methods and constitutes a widely applicable alternative to available tools.
Electronic supplementary material
The online version of this article (doi:10.1186/s13059-015-0617-1) contains supplementary material, which is available to authorized users. 相似文献20.