首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The validation of an analytical method to quantify the antiangiogenic, (Z)-3-[2,4-dimethyl-5-(2-oxo-1,2-dihydro-indol-3-ylidenemethyl)-1H-pyrrol-3-yl]propionic acid (SU006668) for pharmacokinetic determination in a phase I clinical trial, is described. HPLC, with a gradient mobile phase and UV detection at 440 nm, was used. SU006668 was extracted from plasma by precipitation of proteins with acetonitrile. The assay was linear from 25 to 2000 ng/ml (r(2)=0.997); sensitive (limit of quantification 25 ng/ml), accurate (RE 2.6-11.9%) and reproducible (inter-batch precision C.V. 3.2%). Pharmacokinetic data for six patients are presented. They show linear pharmacokinetics with a low volume of distribution and induction at doses of 50, 100 and 200 mg/m(2).  相似文献   

2.
A high-performance liquid-chromatographic (HPLC) assay with UV detection has been developed for the quantitative determination of erlotinib (OSI-774) in human plasma. Quantitative extraction was achieved by a single-solvent extraction involving a mixture of acetonitrile and n-butyl chloride (1:4, v/v). Erlotinib and the internal standard hydrochloride salt (OSI-597) were separated on a column packed with Nova-Pak C18 material and a mobile phase composed of acetonitrile and water, pH 2.0 (60:40, v/v). The column effluent was monitored with dual UV detection at wavelengths of 348 nm (erlotinib) and 383 nm (OSI-597). The calibration graph was linear in the range of 100-4500 ng/ml, with values for accuracy and precision ranging from 87.9 to 96.2% and 2.13 to 5.10%, respectively, for three different sets of quality control samples. The developed method was successfully applied to study the pharmacokinetics of erlotinib in a cancer patient at the recommended daily dose of 150 mg.  相似文献   

3.
A new simple and rapid high-performance liquid chromatographic (HPLC) method with UV detection for the determination of indapamide in biological fluids has been developed. Indapamide and internal standard were isolated from serum and whole blood samples by solid-phase extraction with RP select B cartridges. The chromatographic separation was accomplished on a reversed-phase C(8) column with a mobile phase composed of 0.1% (v/v) triethylamine in water (pH 3.5) and acetonitrile (63:37, v/v). UV detection was set at 240 nm. The calibration curves were linear in the concentration range of 10.0-100.0 ng/ml for serum, and 50.0-500.0 ng/ml for whole blood, and the limits of quantification were 10.0 and 50.0 ng/ml, respectively.  相似文献   

4.
A simple and sensitive high-performance liquid chromatographic (HPLC) method with UV absorbance detection is described for the quantification of donepezil, a centrally and selectively acting acetyleholinesterase inhibitor, in human plasma. After sample alkalinization with 0.5 ml of NaOH (0.1 M), the test compound was extracted from I ml of plasma using isopropanol-hexane (3:97, v/v). The organic phase was back-extracted with 75 microl of HCl (0.1 M) and 50 microl of the acid solution was injected into a C18 STR ODS-II analytical column (5 microm, 150x4.6 mm I.D.). The mobile phase consisted of phosphate buffer (0.02 M, pH 4.6), perchloric acid (6 M) and acetonitrile (59.5:0.5:40, v/v) and was delivered at a flow-rate of 1.0 ml/min at 40 degrees C. The peak was detected using a UV detector set at 315 nm, and the total time for a chromatographic separation was approximately 8 min. The method was validated for the concentration range 3-90 ng/ml. Mean recoveries were 89-98%. Intra- and inter-day relative standard deviations were less than 7.3 and 7.6%, respectively, at the concentrations ranging from 3 to 90 ng/ml. The method shows good specificity with respect to commonly prescribed psychotropic drugs, and it could be successfully applied for pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

5.
A rapid, sensitive and accurate high-performance liquid chromatographic method with UV detection was developed and validated for the quantification of gabapentin in human plasma. Gabapentin was quantified using pre-column derivatization with 1-fluoro-2,4-dinitrobenzene following protein precipitation of plasma with acetonitrile. Amlodipine was used as internal standard. The chromatographic separation was carried out on a Nova-Pak C(18) column using a mixture of 50 mM NaH(2)PO(4) (pH=2.5)-acetonitrile (30:70, v/v) as mobile phase with UV detection at 360 nm. The flow rate was set at 1.5 ml/min. The method was linear over the range of 0.05-5 microg/ml of gabapentin in plasma (r(2)>0.999). The within-day and between-day precision values were in the range of 2-5%. The limit of quantification of the method was 0.05 microg/ml. The method was successfully used to study the pharmacokinetics of gabapentin in healthy volunteers.  相似文献   

6.
A simple, sensitive and reproducible method was developed for the determination of lamotrigine in whole blood with on-line solid phase extraction followed by HPLC separation with UV detection. Whole blood samples were diluted 1:1 with water and then injected directly on a clean-up column dry-packed with 40microm C8 silica and separated on a C18 reversed-phase column (150x4.6mm) at room temperature. The extraction column was activated with methanol and conditioned with phosphate buffer of pH 4.5. Mobile phases consisted of phosphate buffer of pH 4.5 for the extraction column and of phosphate buffer of pH 4.5 - acetonitrile (60:40, v/v) for the analytical column. At a flow rate of 1.0ml/min and a connection time of 1.0min, the complete cycle time was 10.0min. Detection was carried out at 260nm. No internal standard was necessary. The method was linear over concentration range 0.2-20.0microg/ml for lamotrigine. Recovery was 98%. Within-day and between-day coefficients of variation ranged from 1.8 to 6.7%.  相似文献   

7.
A sensitive and specific method for the simultaneous determination of the unchanged drug (solifenacin) and its major metabolite (M1, 4S-hydroxy solifenacin) in rat plasma was developed and validated. Both solifenacin and M1 were extracted from rat plasma by a two-step liquid-liquid extraction and analyzed by semi-micro HPLC with UV detection at an absorbance wavelength of 220 nm. The chromatographic separations were performed on a TSKgel ODS-80Ts (5 microm, 150 mmx2.0 mm i.d.) reversed-phase column with a mobile phase of 0.1 M phosphate buffer (pH 3.0):acetonitrile (71:29, v/v). The intra-day precision (expressed as coefficient of variation, CV) ranged from 0.4% to 1.7%, and the accuracy (expressed as relative error, RE) ranged from -5.2% to 2.0% for solifenacin. The corresponding precision ranged from 1.3% to 3.2%, and accuracy ranged from -4.0% to 8.6% for M1. The lower limit of quantitation for both solifenacin and M1 was 2 ng/ml when 1 ml of plasma was used. No endogenous interference was observed in rat plasma.  相似文献   

8.
The chiral separation of norgestrel enantiomers using reversed-phase high-performance liquid chromatography (RP-HPLC) was studied with hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as chiral mobile phase additive. The effect of mobile phase composition, concentration of HP-beta-CD and column temperature on enantioselective separation were investigated. The quantification properties of the developed RP-HPLC method were examined. A baseline separation of norgestrel enantiomers was achieved on a Agilent ZORBAX Eclipse XDB-C8 column (150 mm x 4.6 mm i.d., 5 microm). The mobile phase was a mixture of acetonitrile and phosphate buffer (pH 5.0, 20 mM) containing 25 mM HP-beta-CD (30:70, v/v) with a flow rate of 1.0 ml/min. The UV detector was set at 240 nm. Calibration curves were linear (n=8) in the range of 0.2-25 microg/ml, the limit of detection and quantitation were 0.10 and 0.20 microg/ml, respectively, for racemic norgestrel. The values of RSD of repeatability and intermediate precision for spiked sample were less than 4.8%. The method was successfully applied to the enantioselective determination of this drug in stereoselective skin permeation study.  相似文献   

9.
Achiral and chiral HPLC methods were developed for clinafloxacin, a quinolone antimicrobial agent. For achiral assay, analytes were isolated from plasma by precipitating plasma proteins. Separation was achieved on a C18 column using an isocratic eluent of ion pairing solution–acetonitrile (80:20, v/v) at 1.0 ml/min with UV detection at 340 nm. The ion pairing solution was 0.05 M citric acid, 1.15 mM tetrabutylammonium hydroxide and 0.1% ammonium perchlorate. Inter-assay accuracy was within 4.9% with an inter-assay precision of 3.7% over a quantitation range of 0.025 to 10.0 μg/ml. For chiral assay, analytes were isolated from plasma by solid-phase extraction. Separation was achieved on a Crownpak CR(+) column using an isocratic eluent of water–methanol (88:12, v/v) containing 0.1 mM decylamine at 1.0 ml/min with UV detection at 340 nm. Perchloric acid was added to adjust pH to 2. Inter-assay accuracy was within 3.5% with a inter-assay precision of 5.4% over a quantitation range of 0.040 to 2.5 μg/ml.  相似文献   

10.
An HPLC method was developed for the determination of a new oxazolidinone, DA-7867 (I), in human plasma and urine and in rat tissue homogenates. To 100 microl of biological sample, 300 microl acetonitrile and 50 microl methanol containing 10 microg/ml DA-7858 (the internal standard) were added. After vortex-mixing and centrifugation, the supernatant was evaporated under a gentle stream of nitrogen. The residue was reconstituted in 100 microl of the mobile phase and a 50-microl aliquot was injected directly onto the reversed-phase (C(18)) column. The mobile phase, 20 mM KH2PO4:acetonitrile (75:25, v/v) was run at a flow rate of 1.5 ml/min and the column effluent was monitored by a UV detector set at 300 nm. The retention times of I and DA-7858 were approximately 6.5 and 8.7 min, respectively. The detection limits of I in human plasma and urine and in rat tissue homogenates were 20, 20, and 50 ng/ml, respectively.  相似文献   

11.
Abouthiouzine is a newly synthesized antithyroid agent with a proposed less adverse effects profile than other currently used drugs. A simple and rapid reversed phase high performance liquid chromatography assay was developed to determine the concentration of abouthiouzine in human plasma. The procedure involved extraction of the drug and propranolol (internal standard) from the plasma using ethylacetate. The extract was evaporated under nitrogen and the residue was constituted with the mobile phase and injected onto micro-Bondapack phenyl column (10 microm, 3.9 mm x 150 mm). The mobile phase consisted of 10 mM potassium dihydrogen phosphate buffer, acetonitrile, and methanol in the ratio of 60:25:15 (v/v/v, pH=3.0), which was delivered at a rate of 1.5 ml/min. Abouthiouzine and the internal standard were monitored using UV detection at 240 nm; the run time was less than 5 min. The detection limit of abouthiouzine is 0.5 microg/ml. The within- and between-day coefficients of variation were less than 7%. Our method has been successfully used to measure abouthiouzine plasma concentrations in a rabbit model following an intravenous administration of the drug.  相似文献   

12.
A gradient reversed-phase HPLC assay has been developed to determine sodium ferulate (SF) in beagle dog plasma with tinidazole as an internal standard. Chromatographic separation was made on a C(18) column using 0.5% acetic acid and acetonitrile (80:20, v/v) as mobile phase. UV detection was performed at 320 nm. The calibration curve for SF was linear in the range of 0.05-10 microg/ml, and the achieved limit of quantification (LOQ) was 51.4 ng/ml. The results of linearity, within- and between-day precision, and accuracy demonstrate that this method is reliable, sensitive and sufficient for in vivo beagle dog pharmacokinetic (PK) studies of SF.  相似文献   

13.
A fully automated gradient high-performance liquid chromatographic method for the determination of isotretinoin, tretinoin and their 4-oxo metabolites in plasma was developed, using the column-switching technique. After dilution with an internal standard solution containing 20% acetonitrile, 0.5 ml of the sample was injected onto a precolumn (17x4.6 mm I.D.), filled with C18 Corasil 37–53 μm. Proteins and polar plasma components were washed out using 1% ammonium acetate-acetonitrile (9:1, v/v) as mobile phase 1. After valve switching, the retained components were transferred to the analytical column in the backflush mode, separated by gradient elution and detected at 360 nm by UV detection. Using two coupled reversed-phase columns (125 mm long), the separation of cis and trans isomers was possible, and all four compounds could be quantified down to 2 ng/ml of plasma. The inter-assay precision in the concentration range 20-1000 ng/ml was between 1.0 and 4.7% for all compounds.  相似文献   

14.
A sensitive high-performance liquid chromatographic method with fluorescence detection has been developed for determination of MCC-555 (5-[[6-(2-fluorbenzyl)-oxy-2-naphy] methyl]-2,4-thiazolidinedione) in beagle dog plasma. Sample preparation was done by protein precipitation with acetonitrile and a synthetic intermediate of MCC-555 (5-[[6-(2-fluorbenzyl)-oxy-2-naphy] methylene]-2,4-thiazolidinedione) was used as the internal standard (IS). The isocratic mobile phase consisted of acetonitrile-10 mmol/l sodium phosphate buffer (pH 4.5) (65:35, v/v) was delivered at a flow rate of 1 ml/min to a Kromasil C(18) reversed-phase column (250 mm x 4.6 mm, 5 microm). The compounds were detected by fluorescence detection, using an excitation wavelength of 232 nm, and emission wavelength of 352 nm. Calibration curves of MCC-555 were linear in the concentration range of 0.005-2.0 microg/ml. Intra- and inter-day precision ranged from 3.4 to 5.4% and 3.0 to 8.8%, respectively. No endogenous interferences were observed with either MCC-555 or IS. The assay is simple, economical, precise, and is directly applicable to pharmacokinetic studies in beagle dogs involving three dose administrations.  相似文献   

15.
A simple and sensitive high-performance liquid chromatography (HPLC) method utilizing UV detection was developed for the determination of plasma pyrrole (Py)-imidazole (Im) polyamides in rats and applied to the pharmacokinetic study of compounds. After deproteinization of plasma with methanol, Py-Im polyamides were analyzed with a reversed-phase TSK-GEL ODS-80TM (4.6 mmx15.0 cm TOSOH Co., Japan) column maintained at 40 degrees C. The mobile phase solvent A was 0.1% acetic acid and the solvent B was HPLC-grade acetonitrile (0-10 min, A: 100-20%, B: 0-80% linear gradient; 10-15 min, A: 40%, B: 60%). The flow rate was 1.0 ml/min. The detection wavelength was set at 310 nm. The method was used to determine the plasma concentration time profiles of Py-Im polyamides after intravenous injection.  相似文献   

16.
An HPLC method was developed to determine levels of mifepristone, in coyote (Canis latrans) serum where mifepristone will be used as an oral contragestive agent for nonlethal predator control. Serum samples were extracted using C(18) solid-phase extraction cartridges. A synthetic analog of mifepristone, RTI-3021-003, was used as the internal standard. Separation of the compounds was achieved by using a C(18) (150 x 4.6 mm) column. The mobile phase was 55% acetonitrile in water running at 1.0 ml/min with UV detection at 305 nm. The assay was linear in the range of 10 to 1000 ng/ml. Inter-day accuracies for 10, 200 and 1000 ng/ml were 95.9, 99.4 and 104.7%, respectively. Inter-day precisions measured by RSD were 19.8, 9.7 and 4.5%. Intra-day accuracies were 117, 106.9 and 99.4% for 10, 200 and 1000 ng/ml, respectively. Intra-day RSDs were 19.7, 3.7 and 9.3%, respectively. A simple, sensitive and validated HPLC analytical method was developed to quantitate mifepristone in canine serum.  相似文献   

17.
A fully automated semi-microbore high performance liquid chromatographic (HPLC) method with column-switching using UV detection was developed for the determination of glimepiride from human plasma samples. Plasma sample (900 microl) was deproteinated and extracted with ethanol and acetonitrile. The extract (70 microl) was directly injected into a Capcell Pak MF Ph-1 pre-column where the primary separation occurred to remove proteins and retain drugs using a mixture of acetonitrile and 10mM phosphate buffer (pH 2.18) (20:80, v/v). The analytes were transferred from the pre-column to an intermediate column using a switching valve and then subsequently separated on an analytical column and monitored with UV detection at 228 nm. Glimepiride was eluted with retention time 34.9 min without interference of endogenous substance from plasma. The limit of quantification (LOQ) was 10 ng/ml for glimepiride. The calibration curves were linear over the concentration range of 10-400 ng/ml (r(2) = 0.9997). Moreover, inter- and intra-day precisions of the method were less than 15% and accuracies were higher than 99%. The developed method was successfully applied for the quantification of glimepiride in human plasma and was used to support a human pharmacokinetic study following a single oral administration of 2 mg glimepiride.  相似文献   

18.
A high-performance liquid chromatography (HPLC) assay was developed for the quantitative determination of 2-methoxyestradiol (2ME2) in human plasma. Sample pretreatment involved a solid-phase extraction of 1 ml aliquots of plasma with C(18) micro-columns. Separation was achieved on a Novapak C(18) column (300 mm x 3.9 mm i.d.; 4 microm PS) at room temperature at an isocratic flow rate of 1 ml/min with 50% acetonitrile in water. Detection was performed at a UV wavelength of 205 nm. Calibration curves were linear in the concentration range of 1-50 ng/ml. The accuracy and precision values obtained from three different sets of quality controls analyzed in replicates of four on four separate occasions ranged from 90.7 to 105.2 and 3.17 to 8.27%, respectively.  相似文献   

19.
A stereoselective reversed-phase HPLC assay to determine S-(-) and R-(+) enantiomers of esmolol in human plasma was developed. The method involved liquid-liquid extraction of esmolol from human plasma, using S-(-)-propranolol as the internal standard, and employed 2,3,4,6-tetra-O-acetyl-beta-d-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The derivatized products were separated on a 5-microm reversed-phase C18 column with a mixture of acetonitrile/0.02 mol/L phosphate buffer (pH 4.5) (55:45, v/v) as mobile phase. The detection of esmolol derivatives was made at lambda=224 nm with UV detector. The assay was linear from 0.035 to 12 microg/ml for each enantiomer. The analytical method afforded average recoveries of 94.8% and 95.5% for S-(-)- and R-(+)-esmolol, respectively. For each enantiomer, the limit of detection was 0.003 microg/ml and the limit of quantification for the method was 0.035 microg/ml (RSD<14%). The reproducibility of the assay was satisfactory.  相似文献   

20.
A simple and rapid capillary zone electrophoresis determination method with UV detection of grepafloxacin and clinafloxacin has been developed. The separation was performed in 35 mM borate-35 mM phosphate buffer solution (pH 8.6), containing 6% (v/v) of acetonitrile. Analyses were realised using fused-silica capillaries (57 cm length x 75 microm I.D.) and the operating conditions were: 15 kV applied voltage, 30 degrees C and detection at 279 nm. Piromidic acid was used as an internal standard. The linear concentration range of application was 1.0-120.0 microg ml(-1) for both compounds, with a detection limit of 0.2 microg ml(-1) for grepafloxacin and 0.3 microg ml(-1) for clinafloxacin. The analysis yielded good reproducibility (RSD between 3.37 and 1.74%). It was applied to the determination of grepafloxacin and clinafloxacin in human and rat urine samples. The method was validated using HPLC as a reference method. Recovery levels were between 94.5 and 103%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏