1.

Background

The aim of this retrospective study was to document the clinical findings and radiological features of idiopathic orbital inflammation syndrome with retro-orbital involvement.

Methods

We searched for ophthalmological patients who received orbital imaging at Zhejiang Provincial People''s Hospital between October 2003 and April 2010. Seventy-three patients were diagnosed with idiopathic orbital inflammation syndrome based on clinicoradiological features, with pathological confirmation of nonspecific inflammatory conditions in 47 patients. Eight patients (11%) had MRI or CT evidence of retro-orbital involvement. All 8 patients were diagnosed with idiopathic orbital inflammation syndrome after biopsy of the orbital lesion. MR images were obtained for all 8 patients; 3 patients also had a contrast-enhanced CT scan.

Results

Seven out of 8 patients with retro-orbital involvement also had orbital apex lesions. Of the 65 patients without retro-orbital involvement, 19 had orbital apex lesions. The difference in the number of patients with orbital apex lesions between the two populations was significant (Fisher exact test P = .002). In all 8 patients with retro-orbital involvement, the inflammation spread through the superior orbital fissure. The retro-orbital lesions were isointense to grey matter on T1-weighted images, hypointense on T2-weighted images, and displayed uniform contrast enhancement; on contrast-enhanced CT scans, they were hyperdense relative to the contralateral mirror area and had radiological contours that were similar to those seen on MR images. The diffuse inflammation with marked sclerosis and hyalinization that we observed in the patients with retro-orbital involvement is consistent with the diagnosis of the sclerosing subtype of idiopathic orbital inflammation syndrome. All 8 patients also complained of mild to moderate periorbital pain (headache).

Conclusions

In patients with idiopathic orbital inflammation syndrome, it is important to perform MRI and CT scans to identify possible retro-orbital involvement. Retro-orbital involvement is more frequent when the lesion is present in the orbital apex.  相似文献   

2.
T Cheung  S Oberoi 《PloS one》2012,7(8):e43405

Introduction

Children with cleft lip and palate (CLP) are known to have airway problems. Previous studies have shown that individuals with CLP have a 30% reduction in nasal airway size compared to non-cleft controls. No reports have been found on cross-sectional area and volume of the pharyngeal airway in clefts. Introduction of Cone-Beam CT (CBCT) and imaging software has facilitated generation of 3D images for assessment of the cross-sectional area and volume of the airway.

Objective

To assess the pharyngeal airway in individuals with CLP using CBCT by measuring volume and smallest cross-sectional areas and compare with 19 age- and sex-matched non-cleft controls.

Methods

Retrospective study of CBCT data of pre-adolescent individuals (N = 19, Mean age = 10.6, 7 females, 12 males, UCLP = 6, BCLP = 3) from the Center for Craniofacial Anomalies. Volumetric analysis was performed using image segmentation features in CB Works 3.0. Volume and smallest cross-sectional were studied in both groups. Seven measurements were repeated to verify reliability using Pearson correlation coefficient. Volume and cross-sectional area differences were analyzed using paired t-tests.

Results

The method was found to be reliable. Individuals with CLP did not exhibit smaller total airway volume and cross sectional area than non-CLP controls.

Conclusion

3D imaging using CBCT and CB Works is reliable for assessing airway volume. Previous studies have shown that the nasal airway is restricted in individuals with CLP. In our study, we found that the pharyngeal airway is not compromised in these individuals.  相似文献   

3.

Background

Radiotherapy treatment requires delivering high homogenous dose to target volume while sparing organs at risk. That is why accurate patient positioning is one of the most important steps during the treatment process. It reduces set-up errors which have a strong influence on the doses given to the target and surrounding tissues.

Aim

The aim of this study was to investigate the efficiency of combining bony anatomy and soft tissue imaging position correction strategies for patients with prostate cancer.

Materials and methods

The study based on pre-treatment position verification results determined for 10 patients using kV images and CBCT match. At the same patients’ position, two orthogonal kV images and set of CT scans were acquired. Both verification methods gave the information about patients’ position changes in vertical, longitudinal and lateral directions.

Results

For 93 verifications, the mean values of kV shifts in vertical, longitudinal and lateral directions equaled: −0.11 ± 0.54 cm, 0.26 ± 0.38 cm and −0.06 ± 0.47 cm, respectively. The same values achieved for CBCT matching equaled: 0.07 ± 0.62 cm, 0.22 ± 0.36 cm and −0.02 ± 0.45 cm. Statistically significant changes between the values of shifts received during the first week of treatment and the rest time of the irradiation process were found for 2 patients in the lateral direction and 2 patients in vertical direction among kV results and for 3 patients in the longitudinal direction among CBCT results. A significant difference between kV and CBCT match results was found in the vertical direction.

Conclusions

In clinical practice, CBCT combined with kV or even portal imaging improves precision and effectiveness of prostate cancer treatment accuracy.  相似文献   

4.
5.

Objective

To compare horizontal eye positions between proptotic thyroid eye disease patients and normal individuals, and to examine positional changes after orbital decompression surgery in thyroid eye disease patients.

Methods

The present case-controlled and retrospective comparative study included 78 proptotic thyroid eye disease patients who underwent bilateral orbital decompression surgery [lateral orbital wall decompression (Group L), 47 patients; medial orbital wall decompression (Group M), 9 patients; and balanced orbital decompression (Group B), 22 patients] and 143 age-matched healthy volunteers as controls. The interpupillary distance was measured to determine horizontal eye positions before and 3 months after surgery in thyroid eye disease patients and was also examined in control eyes. Horizontal eye shifts were calculated by subtracting postoperative from preoperative interpupillary distances.

Results

Preoperative interpupillary distances in thyroid eye disease patients were significantly larger than in controls. The interpupillary distances were significantly decreased postoperatively in Groups M and B, but were significantly increased in Group L. The order of the magnitude of the horizontal shifts was Groups M>B>L.

Conclusions

Proptotic thyroid eye disease patients preoperatively showed laterally displaced eyes in comparison with controls. However, the eyes shifted medially after the medial orbital wall decompression and the balanced orbital decompression, although the former showed more shift. Medial orbital wall or balanced orbital decompression can be used to correct both lateral and anterior displacement of the eyes.  相似文献   

6.

Background

Cone-beam Computed Tomography (CBCT) and stereophotography are two of the latest imaging modalities available for three-dimensional (3-D) visualization of craniofacial structures. However, CBCT provides only limited information on surface texture. This can be overcome by combining the bone images derived from CBCT with 3-D photographs. The objectives of this study were 1) to evaluate the feasibility of integrating 3-D Photos and CBCT images 2) to assess degree of error that may occur during the above processes and 3) to identify facial regions that would be most appropriate for 3-D image registration.

Methodology

CBCT scans and stereophotographic images from 29 patients were used for this study. Two 3-D images corresponding to the skin and bone were extracted from the CBCT data. The 3-D photo was superimposed on the CBCT skin image using relatively immobile areas of the face as a reference. 3-D colour maps were used to assess the accuracy of superimposition were distance differences between the CBCT and 3-D photo were recorded as the signed average and the Root Mean Square (RMS) error.

Principal Findings:

The signed average and RMS of the distance differences between the registered surfaces were −0.018 (±0.129) mm and 0.739 (±0.239) mm respectively. The most errors were found in areas surrounding the lips and the eyes, while minimal errors were noted in the forehead, root of the nose and zygoma.

Conclusions

CBCT and 3-D photographic data can be successfully fused with minimal errors. When compared to RMS, the signed average was found to under-represent the registration error. The virtual 3-D composite craniofacial models permit concurrent assessment of bone and soft tissues during diagnosis and treatment planning.  相似文献   

7.

Objective

Molar intrusion by mini-screw implantation can cause different degrees of root resorption. However, most methods (2-D and 3-D) used for evaluating root resorption have focused on the root length without considering 3-D resorption. The purpose of this study was to volumetrically evaluate root resorption using cone beam computed tomography(CBCT) after mini-screw implant intrusion.

Materials and Methods

1. The volumes of 32 teeth were measured using CBCT and laser scanning to verify the accuracy of CBCT. 2. Twelve overerupted molars from adult patients were investigated in this study. After mini-screw implants were inserted into the buccal and palatal alveolar bones, 150 g of force was applied to the mini-screw implants on each side to intrude the molars. CBCT images of all patients were taken immediately prior to intrusion and after intrusion. The volumes of the roots were calculated using the Mimics software program. The differences between the pre-intrusion and post-intrusion root volumes were statistically evaluated with a paired-samples t-test. In addition, the losses of the roots were statistically compared with each other using one-way analysis of variance at the P<0.05 level.

Results

No statistically significant volume differences were observed between the physical (laser scanning) and CBCT measurements (P>0.05). The overerupted molars were significantly intruded (P<0.05), and the average intrusion was 3.30±1.60 mm. The differences between the pre-intrusion and post-intrusion root volumes were statistically significant for all of the roots investigated (P<0.05). The roots were sorted by volume loss in descending order as follows: mesiobuccal, palatal, and distobuccal. Statistical significance was achieved among the three roots. The average total resorption for each tooth was 58.39±1.54 mm3.

Conclusion

Volume measurement using CBCT was able to effectively evaluate root resorption caused by mini-screw intrusion. The highest volume loss was observed in the mesiobuccal root among the three roots of the investigated first molar teeth.  相似文献   

8.
Orbital volume measurements in enophthalmos using three-dimensional CT imaging   总被引:19,自引:0,他引:19  
The purpose of this study was to investigate enophthalmos by measuring the volume of various orbital structures using off-line computer techniques on images generated by a CT scanner. Eleven patients with enophthalmos had CT scans of the orbits consisting of 30 to 40 adjacent 1.5-mm slices. The data from the scans were analyzed on a Nova 830 stand-alone computer system using software programs that allowed measurement of total bony orbital volume, total soft-tissue volume, globe volume, orbital fat volume, neuromuscular tissue volume, and apex-to-globe distance in the horizontal plane. These data were analyzed comparing the volumes in the normal eye with the volumes in the enophthalmic eye in each patient. The analysis demonstrated a statistically significant increase in bony orbital volume in the enophthalmic eye, but the total soft-tissue volume, fat volume, neuromuscular tissue volume, and globe volume were the same as in the normal eye. The apex-to-globe distance, a measure of the degree of enophthalmos, was less in the enophthalmic eye than in the normal eye. These results suggest that in the majority of patients, the cause of posttraumatic enophthalmos is increased bony orbital volume rather than by soft-tissue loss or fat necrosis. (Several patients showed no volume discrepancies, and it is likely that cicatricial contracture is responsible for the enophthalmos in these cases.) This study suggests that the objective of surgery for correction of enophthalmos in patients with a volume discrepancy should be to decrease the volume of the bony orbit and to increase the anterior projection of the globe.  相似文献   

9.

Importance

The association between hospital volume and inpatient mortality for severe sepsis is unclear.

Objective

To assess the effect of severe sepsis case volume and inpatient mortality.

Design Setting and Participants

Retrospective cohort study from 646,988 patient discharges with severe sepsis from 3,487 hospitals in the Nationwide Inpatient Sample from 2002 to 2011.

Exposures

The exposure of interest was the mean yearly sepsis case volume per hospital divided into tertiles.

Main Outcomes and Measures

Inpatient mortality.

Results

Compared with the highest tertile of severe sepsis volume (>60 cases per year), the odds ratio for inpatient mortality among persons admitted to hospitals in the lowest tertile (≤10 severe sepsis cases per year) was 1.188 (95% CI: 1.074–1.315), while the odds ratio was 1.090 (95% CI: 1.031–1.152) for patients admitted to hospitals in the middle tertile. Similarly, improved survival was seen across the tertiles with an adjusted inpatient mortality incidence of 35.81 (95% CI: 33.64–38.03) for hospitals with the lowest volume of severe sepsis cases and a drop to 32.07 (95% CI: 31.51–32.64) for hospitals with the highest volume.

Conclusions and Relevance

We demonstrate an association between a higher severe sepsis case volume and decreased mortality. The need for a systems-based approach for improved outcomes may require a high volume of severely septic patients.  相似文献   

10.

Objectives

To evaluate the diagnostic value of contrast enhanced post mortem computed tomography (PMCT) in comparison to non-enhanced post mortem CT in the detection of cardiovascular causes of death (COD).

Background

As autopsy rates decline, new methods to determine CODs are necessary. So contrast enhanced PMCT shall be evaluated in comparison to established non-enhanced PMCT in order to further improve the method.

Methods

In a prospective study, 20 corpses were examined using a 64-row multisclice CT (MSCT) before and after intraarterial perfusion with a newly developed, barium-bearing contrast agent and ventilation of the lungs. The cause of death was determined in enhanced and unenhanced scans and a level of confidence (LOC) was given by three experienced radiologists on a scale between 0 and 4. Results were compared to autopsy results as gold standard. Autopsy was performed blinded to PMCT-findings.

Results

The method allowed visualization of different types of cause of death. There was a significant improvement in LOC in enhanced scans compared to unenhanced scans as well as an improvement in the detection of COD. The cause of death could be determined in 19 out of 20 patients.

Conclusions

PMCT is feasible and appears to be robust for diagnosing cardiovascular causes of death. When compared with unenhanced post-mortem CT intraarterial perfusion and pulmonary ventilation significantly improve visualization and diagnostic accuracy. These promising results warrant further studies.  相似文献   

11.

Aim

The aim of this study is to evaluate differences in terms of the setup errors observed using kV planar image compared to CBCT for oesophageal cancer patients.

Background

Planar kV images are quick to acquire but only allow the observation of bony structures. CBCT allows the evaluation of soft tissues, which includes the oesophagus (and tumour) and OAR, giving a more accurate verification of the positioning.

Materials and Methods

All patients were imaged with both techniques between January 2012 and March 2014 were included in the study (16 patients, 212 kV images and 116 CBCT images). Differences between the setup errors observed on the two images modalities were studied. A correlation study between TNM staging, tumour location and immobilization systems with setup errors was also done. Finally, the calculation of systematic and random errors allowed to determine the CTV–PTV margin.

Results

A significant discrepancy (p < 0.05) between the setup errors observed with kV and CBCT was observed in the lateral direction. No statistical correlation was found between setup errors and tumour location, immobilization system or TNM staging. The CTV–PTV margin was smaller with CBCT in the vertical (0.6 cm vs. 0.9 cm) and longitudinal (0.7 cm vs. 1 cm) directions and smaller with kV for the lateral directions (0.8 cm vs. 0.9 cm).

Conclusions

The chosen modality influences the setup error observed which will influence the correction applied. Allowing a better observation of the volumes of interest, CBCT should be the modality of choice in this pathology. The CTV–PTV margins could be shrunk if CBCT is used.  相似文献   

12.

Objective

To present and validate a semi-automatic segmentation protocol to enable an accurate 3D reconstruction of the mandibular condyles using cone beam computed tomography (CBCT).

Materials and Methods

Approval from the regional medical ethics review board was obtained for this study. Bilateral mandibular condyles in ten CBCT datasets of patients were segmented using the currently proposed semi-automatic segmentation protocol. This segmentation protocol combined 3D region-growing and local thresholding algorithms. The segmentation of a total of twenty condyles was performed by two observers. The Dice-coefficient and distance map calculations were used to evaluate the accuracy and reproducibility of the segmented and 3D rendered condyles.

Results

The mean inter-observer Dice-coefficient was 0.98 (range [0.95–0.99]). An average 90th percentile distance of 0.32 mm was found, indicating an excellent inter-observer similarity of the segmented and 3D rendered condyles. No systematic errors were observed in the currently proposed segmentation protocol.

Conclusion

The novel semi-automated segmentation protocol is an accurate and reproducible tool to segment and render condyles in 3D. The implementation of this protocol in the clinical practice allows the CBCT to be used as an imaging modality for the quantitative analysis of condylar morphology.  相似文献   

13.
Yan J  Zhou S  Li Y 《PloS one》2012,7(2):e32111

Purpose

To present rare benign orbital tumors with bone destruction in children who could not be diagnosed pre-surgically and may simulate malignant ones.

Methods

A retrospective review of cases. Clinical, operative and pathological records in all children with a diagnosis of benign orbital tumors who showed remarkable bone destruction at a tertiary Ophthalmic Center in China between Jan 1, 2000 and Dec 31, 2009 were reviewed. All patients had definitive histopathologic diagnosis.

Results

Eight patients with benign orbital tumors showed obvious bone destruction, including six cases of eosinophilic granuloma, one case of leiomyoma and one case of primary orbital intraosseous hemangioma. Among them, three patients were females and five patients were males. Tumors were unilateral in all cases, with both the right and left side affected equally. Age ranged from 3 to 7 years (mean 4.1 years). Symptom duration ranged from 1 to 5 weeks (mean 4.8 weeks). Eyelid swelling and palpable mass were the most common complaint. There was no evidence for multifocal involvement in cases with eosinophilic granuloma. Among six patients with eosinophilic granuloma, two were treated with low dose radiation (10 Gy), three received systemic corticosteroid and one was periodically observed only after incisional biopsy or subtotal curettage. There was no postoperative therapeutic intervention in the two patients with leiomyoma and intraosseous hemangioma. All eight patients regained normal vision without local recurrence after a mean follow-up time of 32.8 months.

Conclusion

Benign orbital tumors such as isolated eosinophilic granuloma, leiomyoma and primary orbital intraosseous hemangioma may show remarkable bone destruction.  相似文献   

14.

Introduction

Proper imaging allows practitioners to evaluate an asymptomatic tempormandibular joint (TMJ) for potential degenerative changes prior to surgical and orthodontic treatment. The recently developed cone-beam computed tomography (CBCT) allows measurement of TMJ bony structures with high accuracy. A study was undertaken to determine the morphology, and its variations, of the mandibular condyle and glenoid fossa among Malay and Chinese Malaysians.

Methods

CBCT was used to assess 200 joints in 100 subjects (mean age, 30.5 years). i-CAT CBCT software and The Mimics 16.0 software were employed to measure the volume, metrical size, position of each condyle sample and the thickness of the roof of the glenoid fossa (RGF).

Results

No significant gender differences were noted in thickness of the RGF and condylar length; however condylar volume, width, height and the joint spaces were significantly greater among males. With regards to comparison of both TMJs, the means of condylar volume, width and length of the right TMJ were significantly higher, while the means of the left condylar height and thickness of RGF were higher. When comparing the condylar measurements and the thickness of RGF between the two ethnic groups, we found no significant difference for all measurements with exception of condylar height, which is higher among Chinese.

Conclusion

The similarity in measurements for Malays and Chinese may be due to their common origin. This information can be clinically useful in establishing the diagnostic criteria for condylar volume, metrical size, and position in the Malaysian East Asians population.  相似文献   

15.

Purpose

A novel phantom for image quality testing for functional magnetic resonance imaging (fMRI) scans is described.

Methods

The cylindrical, rotatable, ~4.5L phantom, with eight wedge-shaped compartments, is used to simulate rest and activated states. The compartments contain NiCl2 doped agar gel with alternating concentrations of agar (1.4%, 1.6%) to produce T1 and T2 values approximating brain grey matter. The Jacard index was used to compare the image distortions for echo planar imaging (EPI) and gradient recalled echo (GRE) scans. Contrast to noise ratio (CNR) was compared across the imaging volume for GRE and EPI.

Results

The mean T2 for the two agar concentrations were found to be 106.5±4.8, 94.5±4.7 ms, and T1 of 1500±40 and 1485±30 ms, respectively. The Jacard index for GRE was generally found to be higher than for EPI (0.95 versus 0.8). The CNR varied from 20 to 50 across the slices and echo times used for EPI scans, and from 20 to 40 across the slices for the GRE scans. The phantom provided a reproducible CNR over 25 days.

Conclusions

The phantom provides a quantifiable signal change over a head-size imaging volume with EPI and GRE sequences, which was used for image quality assessment.  相似文献   

16.

Introduction

In orbital reconstruction, the optimal location of a predefined implant can be planned preoperatively. Surgical results can be assessed intraoperatively or postoperatively. A novel method for quantifying orbital implant position is introduced. The method measures predictability of implant placement: transformation parameters between planned and resulting implant position are quantified.

Methods

The method was tested on 3 human specimen heads. Computed Tomography scans were acquired at baseline with intact orbits (t0), after creation of the defect (t1) and postoperatively after reconstruction of the defect using a preformed implant (t2). Prior to reconstruction, the optimal implant position was planned on the t0 and t1 scans. Postoperatively, the planned and realized implant position were compared. The t0 and t2 scans were fused using iPlan software and the resulting implant was segmented in the fused t2 scan. An implant reference frame was created (Orbital Implant Positioning Frame); the planned implant was transformed to the reference position using an Iterative Closest Point approach. The segmentation of the resulting implant was also registered on the reference position, yielding rotational (pitch, yaw, roll) as well as translational parameters of implant position.

Results

Measurement with the Orbital Implant Positioning Frame proved feasible on all three specimen. The positional outcome provided more thorough and accurate insight in resulting implant position than could be gathered from distance measurements alone. Observer-related errors were abolished from the process, since the method is largely automatic.

Conclusion

A novel method of quantifying surgical outcome in orbital reconstructive surgery was presented. The presented Orbital Implant Positioning Frame assessed all parameters involved in implant displacement. The method proved to be viable on three human specimen heads. Clinically, the method could provide direct feedback intraoperatively and could improve postoperative evaluation of orbital reconstructive surgery.  相似文献   

17.
Huang Y  Morozov A 《PloS one》2011,6(1):e16480

Background

Pyramidal neurons in the hippocampal area CA3 express high levels of BDNF, but how this BDNF contributes to oscillatory properties of hippocampus is unknown.

Methodology/Principal Findings

Here we examined carbachol-induced gamma oscillations in hippocampal slices lacking BDNF gene in the area CA3. The power of oscillations was reduced in the hippocampal area CA1, which coincided with increases in the expression and activity of 5-HT3 receptor. Pharmacological block of this receptor partially restored power of gamma oscillations in slices from KO mice, but had no effect in slices from WT mice.

Conclusion/Significance

These data suggest that BDNF facilitates gamma oscillations in the hippocampus by attenuating signaling through 5-HT3 receptor. Thus, BDNF modulates hippocampal oscillations through serotonergic system.  相似文献   

18.

Background and aim

The clinical use of imaging system in image guided radiotherapy (IGRT) necessitates performing periodic quality assurance of the system to be confident in applying corrections for patient set-up errors. We aim to develop and implement a quality assurance (QA) programme for megavoltage (MV) based image guidance system and assess its long term performance for a period of 3 years.

Materials and methods

Periodic QA tests were performed for the MV planar and cone beam computed tomography (CBCT) imaging system to assess the system safety, mechanical and geometrical accuracy, image quality and dose. The tests were performed using the equipment supplied by the manufacturer along with the image guidance system and using simple methods developed in-house. The test results were compared with expected or baseline values established during commissioning.

Results

The safety system was found to be functional. The results of mechanical and geometrical tests were in good agreement with the expected results. The system mechanical positioning was stable and reproducible within ±2 mm accuracy. The image quality and the imaging dose of the planar and CBCT imaging were found to agree with the baseline values and the manufacturer specifications.

Discussion

Throughout the three-year period, all the QA tests were within the specification. The mechanical and geometrical tests are most crucial as they directly affect the patient positioning accuracy.

Conclusion

We conclude that the MV image guidance system is efficient to perform IGRT and insist to perform periodic QA tests and calibration for the system.  相似文献   

19.

Objective

To develop abdominal magnetic resonance imaging (MRI) protocol to measure pancreatic volume in humans and to validate it in large animals.

Materials and Methods

We performed abdominal MRI in eight mini-pigs using a clinical 3T MRI system. We used consecutive parallel abdominal slices, covering the entire pancreas to calculate pancreatic volume. Following MRI, animals were sacrificed, the pancreas was removed, and the volume of the pancreas was measured by water displacement. We used the same MRI protocol to measure pancreatic volume in 21 humans. To assess reproducibility of in vivo measurement we repeated MRI pancreas volume evaluation within 24 hours in additional five humans.

Results

In mini-pigs the measurements of pancreatic volume by MRI and by water displacement were almost identical (R2 = 0.9867; p<0.0001). In humans the average pancreas volume was 72.7+/−4.5 ml, range from 35.0 to 105.5 ml. This result is in strong agreement with results of previous large postmortem and computed tomography (CT) studies. Repeated measurements of pancreatic volume in humans were highly reproducible. Pancreatic volume measured in vivo was negatively correlated with age, body fat mass, pancreatic TG levels, and visceral fat mass.

Conclusions

These initial results are highly encouraging and our protocol for pancreatic volume estimation in vivo may prove useful in obesity research to follow in vivo changes of pancreatic volume and structure during time course of obesity and type 2 diabetes development.  相似文献   

20.

Background

Effective promotion of exercise could result in substantial savings in healthcare cost expenses in terms of direct medical costs, such as the number of medical appointments. However, this is hampered by our limited knowledge of how to achieve sustained increases in physical activity.

Objectives

To assess the effectiveness of a Primary Health Care (PHC) based physical activity program in reducing the total number of visits to the healthcare center among inactive patients, over a 15-month period.

Research Design

Randomized controlled trial.

Subjects

Three hundred and sixty-two (n = 362) inactive patients suffering from at least one chronic condition were included. One hundred and eighty-three patients (n = 183; mean (SD); 68.3 (8.8) years; 118 women) were randomly allocated to the physical activity program (IG). One hundred and seventy-nine patients (n = 179; 67.2 (9.1) years; 106 women) were allocated to the control group (CG). The IG went through a three-month standardized physical activity program led by physical activity specialists and linked to community resources.

Measures

The total number of medical appointments to the PHC, during twelve months before and after the program, was registered. Self-reported health status (SF-12 version 2) was assessed at baseline (month 0), at the end of the intervention (month 3), and at 12 months follow-up after the end of the intervention (month 15).

Results

The IG had a significantly reduced number of visits during the 12 months after the intervention: 14.8 (8.5). The CG remained about the same: 18.2 (11.1) (P = .002).

Conclusions

Our findings indicate that a 3-month physical activity program linked to community resources is a short-duration, effective and sustainable intervention in inactive patients to decrease rates of PHC visits.

Trial Registration

ClinicalTrials.gov NCT00714831  相似文献   