首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We have developed an integrated automation system for genetic analysis and gene manipulation. The system, SX-8G Plus, is equipped with an 8-nozzle dispensing unit, a thermal cycler, a cooled reagent reservoir, four tip storage racks, four microplate platforms, buffer reservoirs, an agarose gel electrophoresis unit, a power supply, a pump for exchanging electrophoresis buffer, and a CCD camera. Automation of nucleic acid extraction and purification, the most difficult step in automating genetic analysis and gene manipulation, was realized using magnetic beads with Magtration Technology, which we have previously developed for automating the handling of paramagnetic beads. Using this system, we could perform the automated separation and purification of DNA fragments by agarose gel electrophoresis starting from sample loading. The system would enable the automation of almost all procedures in genetic analysis and gene manipulation.  相似文献   

2.
Fluorescent dyes provide specific, sensitive, and multiplexed detection of nucleic acids. To maximize sensitivity, fluorescently labeled reaction products (e.g., cycle sequencing or primer extension products) must be purified away from residual dye-labeled precursors. Successful high-throughput analyses require that this purification be reliable, rapid, and amenable to automation. Common methods for purifying reaction products involve several steps and require processes that are not easily automated. Prolinx®, Inc. has developed RapXtract superparamagnetic separation technology, affording rapid and easy-to-perform methods that yield high-quality product and are easily automated. The technology uses superparamagnetic particles that specifically remove unincorporated dye-labeled precursors. These particles are efficiently pelleted in the presence of a magnetic field, making them ideal for purification because of the rapid separations that they allow. RapXtract-purified sequencing reactions yield data with good signal and high Phred quality scores, and they work with various sequencing dye chemistries, including BigDye and near-infrared fluorescence IRDyes. RapXtract technology can also be used to purify dye primer sequencing reactions, primer extension reactions for genotyping analysis, and nucleic acid labeling reactions for microarray hybridization. The ease of use and versatility of RapXtract technology makes it a good choice for manual or automated purification of fluorescently labeled nucleic acids.  相似文献   

3.
Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versatile method of separating bacteria from these samples and then extracting their microbial DNA. Bacillus atrophaeus subsp. globigii was used as a simulant of Bacillus anthracis. We studied the effects of a broad variety of powdery and environmental samples on PCR detection and the steps required to alleviate their interference. With a benchmark DNA extraction procedure, 17 of the 23 samples investigated interfered with bacterial lysis and/or PCR-based detection. Therefore, we developed the dual-filter method for applied recovery of microbial particles from environmental and powdery samples (DARE). The DARE procedure allows the separation of bacteria from contaminating matrices that interfere with PCR detection. This procedure required only 2 min, while the DNA extraction process lasted 7 min, for a total of <10 min. This sample preparation procedure allowed the recovery of cleaned bacterial spores and relieved detection interference caused by a wide variety of samples. Our procedure was easily completed in a laboratory facility and is amenable to field application and automation.  相似文献   

4.
An analytical process generally involves four main steps: (1) sample preparation; (2) analytical separation; (3) detection; and (4) data handling. In the bioanalytical field, sample preparation is often considered as the time-limiting step. Indeed, the extraction techniques commonly used for biological matrices such as liquid-liquid extraction (LLE) and solid-phase extraction (SPE) are achieved in the off-line mode. In order to perform a high throughput analysis, efforts have been engaged in developing a faster sample purification process. Among different strategies, the introduction of special extraction sorbents, such as the restricted access media (RAM) and large particle supports (LPS), allowing the direct and repetitive injection of complex biological matrices, represents a very attractive approach. Integrated in a liquid chromatography (LC) system, these extraction supports lead to the automation, simplification and speeding up of the sample preparation process. In this paper, RAM and LPS are reviewed and particular attention is given to commercially available supports. Applications of these extraction supports, are presented in single column and column-switching configurations, for the direct analysis of compounds in various biological fluids.  相似文献   

5.
简化核酸提取过程相较于经典的试剂盒法和全自动核酸提取技术,凭借其简便的操作步骤、便携易用的仪器设备和简单的人员培训等优势在病原体核酸检测中得到广泛应用,为实现病原体核酸的快速检测和现场检测(Point-of-care testing,POCT)奠定了良好的基础。本文比较了不同的核酸提取方法,对简化核酸提取过程的方法学进行综述,讨论其在病原体核酸检测领域中的应用现状,并展望其发展趋势。  相似文献   

6.
7.
Chlamydia trachomatis is a leading cause of sexually transmitted infection. Diagnostic methods with easy non-invasive sample collection are important to increase testing and hence to reduce the spread of this infection. To enable more use of urine samples in C. trachomatis diagnostics, automation is an absolute requirement since obtaining high-quality DNA from urine specimens involves extensive processing.

Here, we present a study in which a new automated sample preparation method, BUGS'n BEADS™ STI (BnB STI), was used up-front of the BDProbeTec™ ET end point analysis and compared with the full BDProbeTec™ ET method to analyze C. trachomatis in 1002 urine samples.

The BnB STI system represents a new concept within magnetic sample preparation in which bacteria are first isolated from the sample material followed by purification of bacterial nucleic acid using the same magnetic particles. Similar sensitivity and specificity were obtained with both methods. None of the samples processed with BnB STI inhibited the BDProbeTec™ ET test whereas 1.8% showed inhibition when processed according to the manual BDProbeTec™ ET DNA preparation method. Moreover, the average MOTA scores obtained with the BnB STI system were 48% higher for all amplification controls and 57% higher for positive samples, compared to the manual sample preparation. Based on these results and the significant reduction in hands-on-time for urine sample processing, the automated BnB STI sample preparation method was implemented for routine analysis of C. trachomatis from urine samples.  相似文献   


8.
The field of molecular diagnostics has greatly decreased the time it takes to identify infectious agents and to test their antimicrobial resistance. Portable devices are currently in development that can easily identify a variety of nucleic acid targets (either DNA or RNA) from multiple sample types in under an hour. This is done by a variety of methods including real-time polymerase chain reaction, probe-based assays, bioluminescence real-time amplification, and microarray or micro-pump technologies. These self-contained systems require only minimal training and perform all steps of the assay from extraction through detection with little or no operator intervention.  相似文献   

9.
10.
11.
Electrokinetic techniques are a staple of microscale applications because of their unique ability to perform a variety of fluidic and electrophoretic processes in simple, compact systems with no moving parts. Isotachophoresis (ITP) is a simple and very robust electrokinetic technique that can achieve million-fold preconcentration and efficient separation and extraction based on ionic mobility. For example, we have demonstrated the application of ITP to separation and sensitive detection of unlabeled ionic molecules (e.g. toxins, DNA, rRNA, miRNA) with little or no sample preparation and to extraction and purification of nucleic acids from complex matrices including cell culture, urine, and blood. ITP achieves focusing and separation using an applied electric field and two buffers within a fluidic channel system. For anionic analytes, the leading electrolyte (LE) buffer is chosen such that its anions have higher effective electrophoretic mobility than the anions of the trailing electrolyte (TE) buffer (Effective mobility describes the observable drift velocity of an ion and takes into account the ionization state of the ion, as described in detail by Persat et al.). After establishing an interface between the TE and LE, an electric field is applied such that LE ions move away from the region occupied by TE ions. Sample ions of intermediate effective mobility race ahead of TE ions but cannot overtake LE ions, and so they focus at the LE-TE interface (hereafter called the "ITP interface"). Further, the TE and LE form regions of respectively low and high conductivity, which establish a steep electric field gradient at the ITP interface. This field gradient preconcentrates sample species as they focus. Proper choice of TE and LE results in focusing and purification of target species from other non-focused species and, eventually, separation and segregation of sample species. We here review the physical principles underlying ITP and discuss two standard modes of operation: "peak" and "plateau" modes. In peak mode, relatively dilute sample ions focus together within overlapping narrow peaks at the ITP interface. In plateau mode, more abundant sample ions reach a steady-state concentration and segregate into adjoining plateau-like zones ordered by their effective mobility. Peak and plateau modes arise out of the same underlying physics, but represent distinct regimes differentiated by the initial analyte concentration and/or the amount of time allotted for sample accumulation. We first describe in detail a model peak mode experiment and then demonstrate a peak mode assay for the extraction of nucleic acids from E. coli cell culture. We conclude by presenting a plateau mode assay, where we use a non-focusing tracer (NFT) species to visualize the separation and perform quantitation of amino acids.  相似文献   

12.
A new concept for the improvement of the downstream processing and purification is the so‐called magnetic separation. By using surface functionalized magnetic substrate particles, which selectively adsorb the target product, it can be directly separated out of a crude bioprocess stream. These methods are already used for analytical purposes, where only small amounts of functionalized particles are necessary. To apply the same concept at a larger scale, effective and economical procedures have to be provided. First, suitable process equipment has to be developed. Second, the magnetic particles have to be manufactured with a stable surface functionalization and long‐term stability for their reuse. Up to now mainly high‐gradient magnetic separation filter devices are applied for selective magnetic separation. They consist of a magnetic matrix in which the magnetic particles are trapped. In this work, a new magnetic filter is introduced that overcomes the capacity limitations of the current high‐gradient magnetic separation technology. The principle is demonstrated by selective recovery of lysozyme from hen egg white. Prior to the separation experiments magnetic beads with a strong acid cation‐exchange surface functionalization are synthesized. The separation procedure is implemented in only one unit operation. With the implementation of the displacement elution sequence lysozyme can be separated out of a hen egg white solution with a purification factor of PF=36 and a purity P=0.83.  相似文献   

13.
The effective and robust separation of biomolecules of interest from patient samples is an essential step in diagnostic applications. We present a platform for the fast extraction of nucleic acids from clinical specimens utilizing paramagnetic PMPs, an oil-water interface, a small permanent magnet and a microfluidic channel to separate and purify captured nucleic acids from lysate in less than one minute, circumventing the need for multiple washing steps and greatly simplifying and expediting the purification procedure. Our device was able to isolate influenza RNA from clinical nasopharyngeal swab samples with high efficiency when compared to the Ambion® MagMAXTM Viral RNA Isolation Kit, sufficiently separating nucleic acid analytes from PCR-inhibiting contaminants within the lysate while also critically maintaining high integrity of the viral genome. We find that this design has great potential for rapid, efficient and sensitive nucleic acid separation from patient sample.  相似文献   

14.
15.
Loop-mediated isothermal amplification (LAMP) is a technique capable of rapidly amplifying specific nucleic acid sequences without specialized thermal cycling equipment. In addition, several detection methods that include dye fluorescence, gel electrophoresis, turbidity and colorimetric change, can be used to measure or otherwise detect target amplification. To date, publications have described the requirement for some form of sample nucleic acid extraction (boiling, lysis, DNA purification, etc.) prior to initiating a LAMP reaction. We demonstrate here, the first LAMP positive results obtained from vegetative cells and spores of Bacillus anthracis without nucleic acid extraction. Our data show that the simple addition of cells or spores to the reaction mixture, followed by heating at 63°C is all that is required to reproducibly amplify and detect target plasmid and chromosomal DNA via colorimetric change. The use of three primer sets targeting both plasmids and the chromosome of B. anthracis allows for the rapid discrimination of non-pathogenic bacteria from pathogenic bacteria within 30 min of sampling. Our results indicate that direct testing of B. anthracis spores and cells via LAMP assay will greatly simplify and shorten the detection process by eliminating nucleic acid purification. These results may allow more rapid detection of DNA from pathogenic organisms present in field and environmental samples.  相似文献   

16.
Salicylic acid-coated magnetic nanoparticles were prepared via a modified one-step synthesis and used for a one-stop extraction of genomic DNA from mammalian cells. The synthesized magnetic particles were used for magnetic separation of cells from the media by nonspecific binding of the particles as well as extraction of genomic DNA from the lysate. The quantity and quality were confirmed by agarose gel electrophoresis and polymerase chain reaction. The entire process of extraction and isolation can be completed within 30 min. Compared with traditional methods based on centrifugation and filtration, the established method is fast, simple, reliable, and environmentally friendly.  相似文献   

17.
The application of functionalised magnetic adsorbent particles in combination with magnetic separation techniques has received considerable attention in recent years. The magnetically responsive nature of such adsorbent particles permits their selective manipulation and separation in the presence of other suspended solids. Thus, it becomes possible to magnetically separate selected target species directly out of crude biological process liquors (e.g. fermentation broths, cell disruptates, plasma, milk, whey and plant extracts) simply by binding them on magnetic adsorbents before application of a magnetic field. By using magnetic separation in this way, the several stages of sample pretreatment (especially centrifugation, filtration and membrane separation) that are normally necessary to condition an extract before its application on packed bed chromatography columns, may be eliminated. Magnetic separations are fast, gentle, scaleable, easily automated, can achieve separations that would be impossible or impractical to achieve by other techniques, and have demonstrated credibility in a wide range of disciplines, including minerals processing, wastewater treatment, molecular biology, cell sorting and clinical diagnostics. However, despite the highly attractive qualities of magnetic methods on a process scale, with the exception of wastewater treatment, few attempts to scale up magnetic operations in biotechnology have been reported thus far. The purpose of this review is to summarise the current state of development of protein separation using magnetic adsorbent particles and identify the obstacles that must be overcome if protein purification with magnetic adsorbent particles is to find its way into industrial practice.  相似文献   

18.
Analysis of nucleotide sugar metabolism is essential in studying glycosylation in cells. Here we describe practical methods for both extraction of nucleotide sugars from cell lysates and for their analytical separation. Solid-phase extraction cartridges containing graphitized carbon can be used for the purification of nucleotide sugars by using triethylammonium acetate buffer as a ion-pairing reagent for decreasing retention. After that they are separated by high-performance liquid chromatography using a C18 reversed-phase column and the same ion-pairing reagent for increasing retention. These new sample preparation and analysis methods enable good separation of structurally similar sugar nucleotides, compatibility with rapid evaporative concentration, and possibility to automation. Monitoring the production of GDP-deoxyhexoses in genetically engineered yeast and native bacterial cells are described here as specific applications.  相似文献   

19.
The integration of disposable magnetic filters in combination with functionalized magnetic particles represents a fast and cost‐effective alternative for enzyme purification in comparison to solid/liquid separation by means of centrifugation followed by chromatographic purification. The main advantage of the particle‐based process is the solid/solid/liquid separation in one step combined with disposable equipment. Furthermore this combination provides the possibility to also process biocatalytic reactions in cell‐containing media into disposable equipment with preimmobilized enzymes onto the magnetic particles. The focus of the presented study is on the design and performance of a disposable filtration unit consisting of a plastic bag with an inlet and outlet and a stainless steel filter matrix. During magnetic separation, the magnetic particles selectively retard at the filter matrix due to the magnetic force, which counteracts the drag force. It was found that the length of a lengthwise aligned filter matrix should be longer than the magnetic pole surfaces in fluid flow direction. Hereby, a filtration capacity of 5.6 g magnetic particles was measured with a loss of below 0.5%. Introducing a two‐phase flow optimizes the cleaning of the bag after a magnetic filtration. The procedure offered a high cleaning efficiency. Herewith, the cleaned filter unit could be discarded with minimum losses of product and magnet particles.  相似文献   

20.
The development of portable systems for analysis of nucleic acids (NAs) is crucial for the evolution of biosensing in the context of future healthcare technologies. The integration of NA extraction, purification, and detection modules, properly actuated by microfluidics technologies, is a key point for the development of portable diagnostic systems. In this paper, we describe an integrated biosensor platform based on a silicon–plastic hybrid lab-on-disk technology capable of managing NA extraction, purification, and detection processes in an integrated format. The sample preparation process is performed by solid-phase extraction technology using magnetic beads on a plastic disk, while detection is done through quantitative real-time polymerase chain reaction (qRT-PCR) on a miniaturized silicon device. The movement of sample and reagents is actuated by a centrifugal force induced by a disk actuator instrument. The assessment of the NA extraction and detection performance has been carried out by using hepatitis B virus (HBV) DNA genome as a biological target. The quantification of the qRT-PCR chip in the hybrid disk showed an improvement in sensitivity with respect to the qRT-PCR commercial platforms, which means an optimization of time and cost. Limit of detection and limit of quantification values of about 8 cps/reaction and 26 cps/reaction, respectively, were found by using analytical samples (synthetic clone), while the results with real samples (serum with spiked HBV genome) indicate that the system performs as well as the standard methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏