首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The enzyme immunoassay (EIA) system for the determination of antibodies to capsular polysaccharides of pneumococci, serotypes 1, 3, 6B, 8, 9N, 15F, 23F, and C-polysaccharide has been developed on the basis of poly-L-lysin-modified antigens. The use of isotype-specific conjugates in this system permits the detection of IgG and IgA antibodies in different biological fluids: blood serum, pleural fluid, saliva, milk. Samples obtained from children with pneumococcal infection and from nursing mothers have been studied. As shown in this study, the EIA system can be used for the evaluation of the dynamics of pneumococcal infection in children.  相似文献   

2.
Filter paper discs have been used in the enzyme immunoassay (EIA) as solid phase instead of polystyrene plates. The use of paper discs has made it possible to achieve a multiple increase in the sensitivity of sandwich EIA, thus permitting the detection of Yersinia pestis capsular antigen at a concentration of 0.4 ng/ml. Paper discs can be used not only for the sorption of antigen and antibodies, but also for the affinity purification of preparations.  相似文献   

3.
The result obtained in the study of the possibility of using the method for the determination of the titer of antibodies to herpes simplex virus by EIA techniques in a single dilution of the serum under test are presented. This method is based on the determination of the optical density of the serum titer (rcut) in different groups of sera with the use of the assay system, permitting the evaluation of the positive results obtained in the determination of their final dilution. The results obtained with the use of this method showed that error was 50% for high-titer sera, 60% for medium-titer sera and 30% for low-titer sera.  相似文献   

4.
Some regularities of the enzyme immunoassay (EIA) of whole bacterial cells have been studied on one of the bacillary species of contaminant microflora. Early detection of this microorganism is highly important for the microbiological production of alpha-amylase and alkaline protease (produced by Bacillus subtilis). The effective kinetic and equilibrant parameters of the interaction of peroxidase-labeled antibodies with the cells of the contaminant microflora in the solution and on the surface of the polystyrene plates have been defined. Two methods for the separation of cells after their interaction with peroxidase-labeled antibodies have been optimized: filtration involving the use of special filter plates and centrifugation in plates. The method for the immobilization of cells in the wells of standard assay plates by centrifugation has been proposed. Four EIA methods for measurement of contaminant microflora have been developed and optimized. These methods permit the determination of the microflora at concentration of 5 X 10(5)-5 X 10(4) cells/ml, depending on the scheme of the assay, within 1-3.5 minutes.  相似文献   

5.
The microdot enzyme immunoassay (EIA) has been used for the determination of antibodies to M. tuberculosis protein fractions, crude antigenic preparations, PPD and old tuberculin in tuberculosis patients and healthy persons. Purified protein fractions have been found to possess the highest sensitivity and specificity in microdot EIA. The determination of antibodies to these fractions has permitted the differentiation of persons infected with M. tuberculosis from healthy ones. The use of M. tuberculosis protein fractions permits the determination of IgA and IgC in the sera of tuberculosis patients.  相似文献   

6.
The optimum conditions for the determination of specific antibodies in the sera of brucellosis patients by means of enzyme immunoassay (EIA) have been selected. The comparative study of the specificity and sensitivity of EIA and other serological tests has demonstrated that EIA has high diagnostic effectiveness in the diagnosis of acute and chronic brucellosis. The presence of direct correlation between the results of EIA and Coombs' test is observed, which is indicative of the capacity of EIA for detecting both complete and incomplete specific antibodies. It should be pointed out that in all cases the titer of specific antibodies in EIA has been found to be 5-16 times higher than in Coombs' test, the passive hemagglutination test, and agglutination test.  相似文献   

7.
The data on the approbation of the diagnostic value of the enzyme immunoassay (EIA) system for the determination of diphtheria toxin in the blood sera of diphtheria patients and persons suspected for diphtheria are presented. The EIA system was prepared on the basis of F(ab)2 fractions of purified antidiphtheria antibodies. 240 serum samples from diphtheria and tonsillitis patients and from healthy persons were studied. Diphtheria toxin was determined in all patients with the toxic form of diphtheria and in 41.3% of patients with its localized forms. Blood was taken mainly of the first week of the disease. In healthy persons the results of EIA were negative. Thus, the trial of the assay system in a clinical laboratory showed its good diagnostic effectiveness. The use of this EIA system in medical practice is believed to be quite promising.  相似文献   

8.
Serologic diagnosis has been presented as a safe alternative for coccidioidomycosis. However, commercial kits based on coccidioidal antibodies available in the USA are considered too expensive for laboratories outside that country. In this study, we describe the preparation of antigens for detection of human coccidioidal antibodies by the immunodiffusion test (ID) and enzyme immunoassay (EIA). Antigens were tested against serum samples from patients with coccidioidomycosis, histoplasmosis and paracoccidioidomycosis, as well as healthy individuals. The highest reactivity in the ID tests was seen in the F0-90 antigen. In the EIAs, the best results were obtained with the F60-90 antigen. None of the serum samples from healthy individuals were recognized by any of the antigen extracts tested by ID or EIA. In conclusion, the F0-90 and F60-90 antigens have the potential to be commercially employed in presumptive diagnosis of coccidioidomycosis by ID or EIA, respectively. The tests could improve serological diagnosis of coccidioidomycosis in South America.  相似文献   

9.
We have found that thrombin-induced activation of protein kinase C (PKC) in platelets, measured by phosphorylation of the 47 kDa protein, is synergistically enhanced by the amiloride analogue ethylisopropylamiloride (EIA), a specific inhibitor of Na+/H+ exchange. This EIA effect was further synergistically enhanced by lowering intracellular pH (pHi) with either nigericin or sodium propionate, and reversed by raising pHi with monensin or ammonium chloride. The synergistic enhancement of thrombin-activated PKC by EIA plus nigericin was not observed when PKC was directly activated by phorbol esters. EIA and EIA plus nigericin caused a 3- to 6-fold increase in thrombin-induced diacylglycerol (DAG), but not phosphatidic acid (PA), production. EIA and nigericin also caused a marked increase in thrombin-induced breakdown and inhibition of resynthesis of phosphatidylinositol 4,5-bisphosphate (PIP2). In summary, we have presented evidence that inhibition of Na+/H+ exchange causes primarily a H(+)-mediated interruption of the phosphoinositide cycle in activated platelets, including the accumulation of DAG associated with the enhancement of PKC activation, the inhibition of conversion of DAG to PA, and increased PIP2 breakdown. These data suggest a model in which Na+/H+ and pHi play an important regulatory role in permitting the phosphoinositide cycle to proceed in thrombin-activated platelets.  相似文献   

10.
The effectiveness of the solid-phase enzyme immunoassay (EIA) in the determination of the specific activity of rabies vaccines is evaluated in comparison with that of the protective test in mice. Inactivated tissue-culture, concentrated tissue-culture and purified cerebral tissue vaccines for human use were studied. The methods for performing two EIA variants and evaluating the results are described. The average level of correlation between the results of EIA and the protective test for vaccines of different groups was revealed (0.546), the highest correlation index being obtained for tissue-culture vaccines: 0.753. On the basis of the data obtained in this study the expediency of using EIA for the determination of the specific activity of rabies vaccines has been substantiated.  相似文献   

11.
The diagnostic value of the first experimental production batches of assay kit "DIAGN-A-HEP", produced at the Institute of Poliomyelitis and Viral Encephalitides (USSR Acad. Med. Sci.) and intended for the determination of IgM to hepatitis A virus (HAV) in the enzyme immunoassay (EIA), has been studied in comparison with that of the internationally known and widely approved commercial EIA system "HAVAB-MEIA" for the determination of antibodies to HAV (the product of Abbott, USA). The study has revealed that the EIA kit "DIAGN-A-HEP" is highly sensitive and specific, and the diagnostic value of this kit is not inferior to that of the commercial assay system "HAVAB-MEIA". On the basis of this study the use of the EIA kits "DIAGN-A-HEP" in medical practice has been allowed by the decree of the Ministry of Health of the USSR.  相似文献   

12.
Two variants of the enzyme immunoassay (EIA) systems for the determination of B. pertussis toxin (BPT), the "double sandwich" system and the competitive assay system, have been developed. For the titration of BPT in B. pertussis antigens the use of fetuin as the affinity base is preferable, and not antibodies from different paired animals. Of the two variants, the competitive EIA is more promising for diagnostic purposes.  相似文献   

13.
Antibodies against the herbicide chlorsulfuron have been raised and characterized. Enzyme immunoassays (EIAs) for chlorsulfuron, involving labeled antigen or labeled antibodies, have been developed. The kinetics of antigen-antibody interactions in the EIA systems developed has been studied. Both systems exhibit equal sensitivity (1 ng/ml). The values of the coefficient of variation (CV), determined within the range of chlorsulfuron concentrations 1-100 ng/ml to be measured by the systems, are not in excess of 8%. The possibility of using glucose oxidase as a label in EIAs for chlorsulfuron has been demonstrated. Lack of cross-reactivity with a series of sulfonyl- and arylurea derivatives and triazines makes it possible to recommend the EIA systems developed for chlorsulfuron determination in the environment.  相似文献   

14.
Children immunized with live measles vaccine in the foci of measles infection varying in intensity (1-9 cases per focus) have been subjected by two methods: the hemagglutination inhibition (HAI) test and the enzyme immunoassay (EIA). As shown in this study, in most cases (98% of all blood serum samples) the correlation between the results of the HAI test and EIA is not high (r = 0.5), which is linked with the detection of a wider spectrum of antibodies in EIA. The percentage of seronegative children detected by these two methods was practically the same (4.05 and 4.4, respectively). The analysis of the results obtained in this study indicates that EIA is a more informative and sensitive method, which confirms the effectiveness of its use for the determination of the level of collective immunity.  相似文献   

15.
Highly sensitive and specific erythrocyte diagnostic agents (ED) for the determination of antibodies to Proteus O-antigens have been obtained by the sensitization of formolated sheep red blood cells (SPBC) with activated lipopolysaccharides (LPS) without the use of mediators. The tannin treatment of formolated SRBC and/or the increase of temperature from 45 degrees C to 100 degrees C in the process of the preparation of ED have been found to produce no increase in effectiveness. Antibody ED permitting the detection of Proteus O- and H-antigens has been obtained by the sensitization of formolated chick red blood cells with immunoglobulin preparations to Proteus hydroxylamine antigens, carried out with the use of amidol. The experiments have shown the possibility of using this antibody ED for the determination of O-antibodies in the antigen neutralization test with nonactivated LPS used as an agglutinating agent. The passive hemagglutination test with antibody ED has proved to be a more sensitive method for the detection of O-antibodies than the antigen neutralization test with antigenic ED. The determination of Proteus etiology in the passive hemagglutination test with the use of antigenic ED has been shown to be highly effective in the examination of patients with chronic osteomyelitis at the stage of exacerbation.  相似文献   

16.
Newly developed serological methods for the detection of pili in the passive hemagglutination (PHA) test with the use of immunoglobulin erythrocytic diagnosticum and in the enzyme immunoassay (EIA) with the use of specific immunoglobulins labeled with horse radish peroxidase have been found to exceed the method of detecting pili, based on the determination of their hemagglutinating activity, in sensitivity and specificity. Besides, the PHA test and EIA have proved to be capable of detecting low molecular fragments of pili, obtained by sonication and having lost their hemagglutinating activity.  相似文献   

17.
Development of Enzyme Immunoassays for the Herbicide Chlorsulfuron   总被引:2,自引:0,他引:2  
Antibodies against the herbicide chlorsulfuron have been raised and characterized. Enzyme immunoassays (EIAs) for chlorsulfuron, involving labeled antigen or labeled antibodies, have been developed. The kinetics of antigen–antibody interactions in the EIA systems developed has been studied. Both systems exhibit equal sensitivity (1 ng/ml). The values of the coefficient of variation (CV), determined within the range of chlorsulfuron concentrations to be measured by the systems (1–100 ng/ml), are not in excess of 8%. The possibility of using glucose oxidase as a label in EIAs for chlorsulfuron has been demonstrated. Lack of cross-reactivity with a series of sulfonyl-/arylurea derivatives and triazines makes it possible to recommend the EIA systems developed for chlorsulfuron determination in the environment.  相似文献   

18.
Historically, methods used to identify Vibrio vulnificus in environmental samples have been inadequate because isolation and identification procedures are time-consuming and fail to separate V. vulnificus from other bacterial species. We describe an enzyme immunoassay (EIA) and culture techniques which identified V. vulnificus in seawater, sediment, and oysters. The EIA used monoclonal antibody FRBT37 to a species-specific epitope of V. vulnificus. No cross-reactions were observed among 72 non-V. vulnificus strains comprising 34 species and 15 genera. In field trials, the EIA identified correctly 99.7% of 348 biochemically confirmed V. vulnificus isolates. The epitope corresponding to FRBT37 was found in cells lysed by Triton X-100, deionized H2O, and ultrasonication but was not found in culture supernatants, indicating that its location was intracellular. In addition, electron micrographs of V. vulnificus labeled with FRBT37-biotin-avidin-gold showed that epitope FRBT37 reacted with fragments of lysed cells but not whole cells. FRBT37 was expressed when V. vulnificus was cultured in different growth media. The minimum level of detection of the EIA was approximately 2,000 V. vulnificus cells per EIA well. Epitope FRBT37 was labile at 70 degrees C for 30 min. Immunoblot and EIA plate formats reduced assay time and facilitated handling large numbers of test samples.  相似文献   

19.
Historically, methods used to identify Vibrio vulnificus in environmental samples have been inadequate because isolation and identification procedures are time-consuming and fail to separate V. vulnificus from other bacterial species. We describe an enzyme immunoassay (EIA) and culture techniques which identified V. vulnificus in seawater, sediment, and oysters. The EIA used monoclonal antibody FRBT37 to a species-specific epitope of V. vulnificus. No cross-reactions were observed among 72 non-V. vulnificus strains comprising 34 species and 15 genera. In field trials, the EIA identified correctly 99.7% of 348 biochemically confirmed V. vulnificus isolates. The epitope corresponding to FRBT37 was found in cells lysed by Triton X-100, deionized H2O, and ultrasonication but was not found in culture supernatants, indicating that its location was intracellular. In addition, electron micrographs of V. vulnificus labeled with FRBT37-biotin-avidin-gold showed that epitope FRBT37 reacted with fragments of lysed cells but not whole cells. FRBT37 was expressed when V. vulnificus was cultured in different growth media. The minimum level of detection of the EIA was approximately 2,000 V. vulnificus cells per EIA well. Epitope FRBT37 was labile at 70 degrees C for 30 min. Immunoblot and EIA plate formats reduced assay time and facilitated handling large numbers of test samples.  相似文献   

20.
The results of the work on the development of an enzyme immunoassay (EIA) system for the determination of secretory IgA (S-IgA) are presented. A first, S-IgA was isolated from human colostrum and used as the basis for obtaining biologically active immunosorbent; then antibodies to S-IgA were isolated and the specific conjugate was obtained. The determination of S-IgA was carried out by the method of sandwich EIA. The newly developed EIA system permitted the determination of S-IgA only, giving no positive reactions with serum immunoglobulins. The data thus obtained make it possible to regard this assay system as specific, sensitive and suitable for further trials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号