首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A functional analysis of the striated swim-bladder muscles engaged in the sound production of the toadfish has been performed by simultaneous recording of muscle action potentials, mechanical effects, and sound. Experiments with electrical nerve stimulation were made on excised bladder, while decerebrate preparations were used for studies of reflex activation of bladders in situ. The muscle twitch in response to a single maximal nerve volley was found to be very fast. The average contraction time was 5 msec. with a range from 3 to 8 msec., the relaxation being somewhat slower. The analysis of muscle action potentials with surface electrodes showed that the activity of the muscle fibers running transversely to the long axis of the muscle was well synchronized both during artificial and reflex activation. With inserted metal microelectrodes monophasic potentials of 0.4 msec. rise time and 1.2 to 1.5 msec. total duration were recorded. The interval between peak of action potential and onset of contraction was only 0.5 msec. Microphonic recordings of the characteristic sound effect accompanying each contraction showed a high amplitude diphasic deflection during the early part of the contraction. During relaxation a similar but smaller deflection of opposite phase could sometimes be distinguished above the noise level. The output from the microphone was interpreted as a higher order derivative function of the muscle displacement. This interpretation was supported by complementary experiments on muscle sound in mammalian muscle. The dependence of the sound effects on the rate of muscle contraction was demonstrated by changing the temperature of the preparation and, in addition, by a special series of experiments with repeated stimulation at short intervals. Results obtained by varying the pressure within the bladder provided further evidence for the view that the sound initiated in the muscle is reinforced by bladder resonance. Analysis of spontaneous grunts confirmed the finding of a predominant sound frequency of about 100 per second, which was also found in reflexly evoked grunts. During these, muscle action potentials of the same rate as the dominant sound frequency were recorded, the activity being synchronous in the muscles on both sides. Some factors possibly contributing to rapid contraction are discussed.  相似文献   

2.
Motor unit action potentials (MUAPs) of brachial biceps were simulated. A simulated MUAP was obtained as a sum of single fibre action potentials (SFAPs) from all the muscle fibres of a motor unit (MU). The influence of the following factors on MUAP shape for different kinds of recording electrode was studied: fibre density, neuromuscular jitter, temporal dispersion and electrode displacements. The simulation confirms that typical MUAPs recorded with needle electrodes from muscles of low fibre density such as brachial biceps are usually triphasic. Increased fibre density produces MUAPs of more complex shape and higher amplitude. Normal neuromuscular jitter is responsible for the variability of shape of subsequent potentials from the same MU as well as for electromyographic shimmer. Pathologic (increased) jitter makes the shapes of subsequent potentials unrecognizable. The influence of temporal dispersion is interconnected with other factors but rather of minor importance. The simulation shows how big changes in MUAP shape can be expected due to electrode displacements during single experiment or during estimation of MU territory.  相似文献   

3.
The relationship between diaphragm electromyogram (EMG), isometric force, and length was studied in the canine diaphragm strip with intact blood supply and innervation under three conditions: supramaximal tetanic (100 Hz) phrenic nerve stimulation (STPS; n = 12), supramaximal phrenic stimulation at 25 Hz (n = 15), and submaximal phrenic stimulation at 25 Hz (n = 5). In the same preparation, the EMG-length relationship was also examined with direct muscle stimulation when the neuromuscular junction was blocked. EMG from three different sites and via two types of electrodes (direct or sewn-in and surface) were recorded during isometric contraction at different lengths. Direct EMGs were recorded from two bipolar electrodes sutured into the strip, one near its central end and the other near its costal end. A third EMG electrode configuration summed potentials from the whole strip by recording potentials between central and costal sites. Surface EMGs were recorded by a bipolar spring clip electrode that made contact with upper and lower surfaces of the muscle strip with light pressure. In all conditions of stimulation with different types of electrodes, all EMGs decreased significantly (P less than 0.05) when muscle length was changed from 50 to 120% of resting length (L0). Minimal and maximal force outputs were observed at 50 and 120% of L0, respectively, in all experiments. The results of this study indicated that the muscle length is a significant variable that affects the EMG recording and that the diaphragmatic EMG may not be an accurate reflection of phrenic nerve activity.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

4.
Recent advances in the technology of recording magnetic fields associated with electric current flow in biological tissues have provided a means of examining action currents that is more direct and possibly more accurate than conventional electrical recording. Magnetic recordings are relatively insensitive to muscle movement, and, because the recording probes are not directly connected to the tissue, distortions of the data due to changes in the electrochemical interface between the probes and the tissue are eliminated. In vivo magnetic recordings of action currents of rat common peroneal nerve and extensor digitorum longus (EDL) muscle were obtained by a new magnetic probe and amplifier system that operates within the physiological temperature range. The magnetically recorded waveforms were compared with those obtained simultaneously by conventional, extracellular recording techniques. We used the amplitude of EDL twitch force (an index of stimulus strength) generated in response to graded stimulation of the common peroneal nerve to enable us to compare the amplitudes of magnetically recorded nerve and muscle compound action currents (NCACs and MCACs, respectively) with the amplitudes of electrically recorded nerve compound action potentials (NCAPs). High, positive correlations to stimulus strength were found for NCACs (r = 0.998), MCACs (r = 0.974), and NCAPs (r = 0.998). We also computed the correlations of EDL single motor unit twitch force with magnetically recorded single motor unit compound action currents (SMUCACs) and electrically recorded single motor unit compound action potentials (SMUCAPs) obtained with both a ring electrode and a straight wire serving as a point electrode. Only the SMUCACs had a relatively strong positive correlation (r = 0.768) with EDL twitch force. Correlations for ring and wire electrode-recorded SMUCAPs were 0.565 and -0.366, respectively. This study adds a relatively direct examination of action currents to the characterization of the normal biophysical properties of peripheral nerve, muscle, and muscle single motor units.  相似文献   

5.
We examined whether electrical field stimulation with varying characteristics could excite isolated mammalian skeletal muscle through different sites. Supramaximal (20-V, 0.1-ms) pulse stimulation with transverse wire or parallel plate electrodes evoked similar forces in nonfatigued slow-twitch soleus and fast-twitch extensor digitorum longus (EDL) muscles from mice. d-tubocurarine shifted the twitch force-stimulation strength relationship toward higher pulse strengths with both electrode configurations in soleus muscle, suggesting that weaker pulses excite muscle via neuromuscular transmission. With wire stimulation, movement of the recording electrode along the muscle caused a delay between the stimulus artifact and the peak of the action potential, consistent with action potential propagation along the sarcolemma. TTX abolished all contractions evoked with 20-V, 0.1-ms pulses, suggesting that excitation occurred via voltage-dependent Na+ channels and, hence, muscle action potentials. TTX did not prevent force development with > or = 0.4-ms pulses in soleus or 1-ms pulses in EDL muscle. Furthermore, myoplasmic Ca2+ (i.e., the fura 2 ratio) and sarcomere shortening were greater during tetanic stimulation with 2.0-ms than with 0.5-ms pulses in flexor digitorum brevis fibers from rats. TTX prevented all shortening and Ca2+ release with 0.5-ms, but not 2.0-ms, pulses, indicating that longer pulses can directly trigger Ca2+ release. Hence, proper interpretation of mechanistic studies requires precise understanding of how muscles are excited; otherwise, incorrect conclusions can be made. Using this new understanding, we showed that disrupted propagation of action potentials along the surface membrane is a major cause of fatigue in soleus muscle that is focally and continuously stimulated at 125 Hz.  相似文献   

6.
It is currently not possible to record electromyographic (EMG) signals from many locations concurrently inside the muscle in a single wire electrode system. We developed a thin-film wire electrode system for multichannel intramuscular EMG recordings. The system was fabricated using a micromachining process, with a silicon wafer as production platform for polyimide-based electrodes. In the current prototype, the flexible polymer structure is 220 microm wide, 10 microm thick, and 1.5 cm long, and it has eight circular platinum-platinum chloride recording sites of 40-microm diameter distributed along the front and back surfaces with 1,500-microm intersite spacing. The system prototype was tested in six experiments where the electrode was implanted into the medial head of the gastrocnemius muscle of rabbits, perpendicular to the pennation angle of the muscle fibers. Asynchronous motor unit activity was induced by eliciting the withdrawal reflex or sequential crushes of the sciatic nerve using a pair of forceps. Sixty-seven motor units were identified from these recordings. In the bandwidth 200 Hz to 5 kHz, the peak-to-peak amplitude of the action potentials of the detected motor units was 75 +/- 12 muV and the root mean square of the noise was 1.6 +/- 0.4 muV. The noise level and amplitude of the action potentials were similar for measures separated by up to 40 min. The experimental tests demonstrated that thin film is a promising technology for a new type of flexible-wire intramuscular EMG recording system with multiple detection sites.  相似文献   

7.
A PROCESS called “excitation-contraction coupling” has been generally accepted to take place only in the direction of excitation to contraction. Through this mechanism a propagated action potential initiates an active state in skeletal or cardiac muscle and the muscle contracts. We propose that, in the mammalian ventricular myocardium at least, the process is not unidirectional and an important reverse coupling between the contractile system and the excitable plasma membrane has been overlooked. Through this feedback interaction the mode of contraction (that is, isotonic or isometric) not only determines the instantaneous electrical state of the plasma membrane, but also influences the mechanical events of the subsequent beats. Thus when Kaufmann et al.1 recorded intracellular action potentials from cat papillary muscle, the time course of the repolarization was altered depending on the mode of contraction. Some kind of contraction-excitation feedback has also been suggested by Stauch2 and Lab3,4. They showed a difference in the shape of the monophasic action potential, as recorded by a suction electrode, when comparing isotonic and isovolumic contraction of the intact ventricle. But their experimental conditions did not allow satisfactory analysis of the phenomenon.  相似文献   

8.
Electrophysiological experiments are helpful for students to understand the role of electrical activity in heart function. Papillary muscle, which belongs to the ventricle, offers the advantage of being easily studied using glass microelectrodes. In addition, there is commercially available software that simulates ventricular electrical activity and can help overcome some difficulties, such as voltage clamp experiments, which need expensive apparatus when used for studies on living preparations. Here, we present a class practical session that is taken by undergraduate students at our University. In the first part of this class, students record action potentials from papillary muscles with the use of glass microelectrodes, and they change extracellular conditions to study the ionic basis of the action potential. In the second part of the class, students simulate action potentials using the Oxsoft Heart model (v. 4.0) and model their previous experiments on papillary muscle to quantify the effects. In particular, the model is very helpful in promoting understanding of the effect that extracellular potassium has on cardiac action potential by simulating voltage clamp experiments. This twin approach of papillary muscle experiments and computer modeling leads to a good understanding of the functioning of the action potential and can help introduce discussion of some abnormal cardiac functioning.  相似文献   

9.
There are two possible mechanisms of effects of large electric fields on animals, one caused by the electric field at the body surface and the other caused by the electric current induced inside the body. The purpose of the present experiments was to investigate the former possibility by recording action potentials from afferent fibers innervating various sensory receptors in the cat's hindlimb. Cat hairs were attracted to the upper electrode when exposed to DC electric fields of 180 kV/m or greater, and action potentials were evoked in the afferent fibers innervating G1, G2, and down hair receptors. No action potentials were evoked in afferent fibers innervating type I, type II, field receptors, muscle spindles, or joint receptors. These results indicate that a strong DC electric field induced movement of the hairs, eventually evoked excitation of the hair receptors, but that other receptors located under the skin were not influenced by electric field exposure.  相似文献   

10.
The amplitude of the surface EMG does not reach the level achieved during a maximal voluntary contraction force at the end of a sustained, submaximal contraction, despite near-maximal levels of voluntary effort. The depression of EMG amplitude may be explained by several neural and muscular adjustments during fatiguing contractions, including decreased net neural drive to the muscle, changes in the shape of the motor unit action potentials, and EMG amplitude cancellation. The changes in these parameters for the entire motor unit pool, however, cannot be measured experimentally. The present study used a computational model to simulate the adjustments during sustained isometric contractions and thereby determine the relative importance of these factors in explaining the submaximal levels of EMG amplitude at task failure. The simulation results indicated that the amount of amplitude cancellation in the simulated EMG (~ 40%) exhibited a negligible change during the fatiguing contractions. Instead, the main determinant of the submaximal EMG amplitude at task failure was a decrease in muscle activation (number of muscle fiber action potentials), due to a reduction in the net synaptic input to motor neurons, with a lesser contribution from changes in the shape of the motor unit action potentials. Despite the association between the submaximal EMG amplitude and reduced muscle activation, the deficit in EMG amplitude at task failure was not consistently associated with the decrease in neural drive (number of motor unit action potentials) to the muscle. This indicates that the EMG amplitude cannot be used as an index of neural drive.  相似文献   

11.
Firing pattern of skeletomotor neurones innervating triceps surae muscles in response to pseudorandom muscle stretching and white noise modulated transmembrane current stimulation was investigated in decerebrate cats. Pseudo-random muscle stretching (upper cut-off frequency 60 Hz, amplitude (standard deviation) ranging from 18.5 m to 40 m) was applied to triceps surae muscles. Membrane potential changes and action potentials of skeletomotor neurones were recorded intracellularly. White noise modulated current was applied through the same (recording) microelectrode. Sequences of ten identical 5 s periods of either muscle stretching or transmembrane current stimulation were applied. Skeletomotor neurones belonging to slow motor units (rheobase less than 8.5 nA) generated action potentials in response to both pseudo-random muscle stretching and transmembrane current stimulation, while firing threshold of those belonging to fast motor units could not be reached by the muscle stretches applied. Peri-spike averaging of muscle length and injected current records showed that the action potentials appeared at the peak of either depolarizing current wave or muscle stretching both preceded by a change in opposite direction (the spikes coinciding with the peak in muscle length PSA being actually elicited by muscle spindle action potentials triggered at the moment of the peak stretching velocity). Time coupling of action potentials occurred during both muscle stretching and transmembrane stimulation, being more tight in the latter case as well as when larger amplitudes of the stimuli were applied. It is supposed that discharges from muscle spindle primary endings phase-locked to small pseudo-random muscle length changes may, due to the time coupling of skeletomotor action potentials, provoke a synchronous firing of skeletomotor neurones, mostly of those belonging to slow motor units. Possible effects of such a firing pattern on the resulting muscle reflex contraction and the stretch reflex stability as well as a possibility of it being provoked by fusimotor discharges are discussed.  相似文献   

12.
Recently, high-density surface EMG electrode grids and multi-channel amplifiers became available for non-invasive recording of human motor units (MUs). We present a way to decompose surface EMG signals into MU firing patterns, whereby we concentrate on the importance of two-dimensional spatial differences between the MU action potentials (MUAPs). Our method is exemplified with high-density EMG data from the vastus lateralis muscle of a single subject. Bipolar and Laplacian spatial filtering was applied to the monopolar raw signals. From the single recording in this subject six different simultaneously active MUs could be distinguished using the spatial differences between MUAPs in the direction perpendicular to the muscle fiber direction. After spike-triggered averaging, 125-channel two-dimensional MUAP templates were obtained. Template-matching allowed tracking of all MU firings. The impact of spatial information was measured by using subsets of the MUAP templates, either in parallel or perpendicular to the muscle fiber direction. The use of one-dimensional spatial information perpendicular to the muscle fiber direction was superior to the use of a linear array electrode in the longitudinal direction. However, to detect the firing events of the MUs with a high accuracy, as needed for instance for estimation of firing synchrony, two-dimensional information from the complete grid electrode appears essential.  相似文献   

13.
The spatial analysis of the potentials of single motor units of the rat medial gastrocnemius muscle evoked by stimulation of the fibres of split ventral roots was carried out with a bipolar electrode moving in the direction perpendicular to the longitudinal axis of the muscle fibres. During this movement of the electrode a variability was observed in the time of the biphasic potential from its maximum to minimum, and in the peak-to-peak amplitude of these potentials. The potentials recorded outside the territory of the motor unit had a lower amplitude in relation to the potentials from the territory of the unit. This made localization of the motor unit on the cross-section of the muscle possible. Differences in the duration of the potential from maximal to minimal amplitude (maximum-minimum amplitude time--M-MAT) of each investigated motor unit from successive recording sites reflected the number of fibres contributing to the action potential and the distance of the recording surface of the electrode from the zone of the motor end-plates of this motor unit. The greatest diameter of the territory of the observed motor units reached 2.5 mm.  相似文献   

14.
Single cells were trypsin-dispersed from blood vessels (great vessels near the heart and mesenteric vessels) of 10–20 day chick embryos, and induced to reaggregate into small spheres (0.1–0.5 mm ) either by gyration or by plating on cellophane. Many reaggregates contracted spontaneously or in response to electrical stimulation during culture periods of up to 6 weeks. When the spherical reaggregates were allowed to adhere to a glass substrate, cells emigrated from the spheres to form aprons of monolayered cells which continued to contract. Thick and thin myofilaments (mean diameters of 146 and 65 Å, respectively) were observable in a large fraction of cells studied in electron micrographs. Vascular smooth muscle (VSM) cells were identified in the reaggregates by recording resting potentials of −40 to −60 mV, and by action potential generation. The action potentials were preceded by pacemaker potentials, had slow rates of rise (<20 V/sec), and were insensitive to tetrodotoxin (TTX). Although the action potentials depend on an inward slow current, D-600 did not block the action potentials of the VSM cells. Reaggregates of atrial cells, produced at the same time for comparison, had larger resting potentials (up to −80 mV), less automaticity, fast rates of rise (mean of about 85 V/sec), and complete TTX sensitivity, thus indicating dependence on fast Na+ channels. These findings indicate that identifiable VSM cells can be successfully maintained in primary culture for several weeks, and these cells retain electrical and contractile properties similar to those of smooth muscle cells in intact adult blood vessels. This preparation provides a convenient system for electrophysiological and pharmacological studies of VSM cells.  相似文献   

15.
'End plate spike' (EPS) is a spontaneous action potential of a normal striated muscle. EPSs are found in local 'active spots' of the muscle. The prevailing hypothesis about the origin of EPSs states that when a needle electrode affects a motor nerve branch near the neuromuscular junction at the end plate zone, an increased leakage of acetylcholine to the synaptic cleft ensues. This elicits postsynaptic action potentials of the muscle fibre which can be recorded as EPSs with the same needle electrode. Thus EPSs are thought to be caused by needle injury or irritation of the motor axon. We suggest that EPSs are action potentials of intrafusal muscle fibres and that 'active spots' are in fact muscle spindles. Waveform analysis reveals three types of EPSs: small EPSs, not propagated outside the active spot either: i) with negative onset; or ii) with short positive initial deflection; and iii) large EPSs resembling propagated motor unit potentials (MUPs) but with a typical EPS firing pattern, distinctly different from that of the MUPs. Study of EPS activation in different manoeuvres associates small EPSs with intrafusal gamma motor units and large MUP-like EPSs with beta motor units.  相似文献   

16.
Using simultaneous intracellular recordings, we have characterized 1) electrical activity in the longitudinal muscle (LM) of isolated segments of guinea pig distal colon free to contract spontaneously and 2) extent of propagation of spontaneous action potentials around the circumference of the colon. In all animals, rhythmical spontaneous depolarizations (SDs) were recorded that are usually associated with the generation of action potentials. Recordings from pairs of LM cells, separated by 100 microm in the circumferential axis, revealed that each action potential was phase locked at the two electrodes (mean propagation velocity: 3 mm/s). However, at an increased electrode separation distance of 1 mm circumferentially, action potentials and SDs became increasingly uncoordinated at the two recording sites. No SDs or action potentials ever propagated from one circumferential edge to the other (i.e., 13 mm apart). When LM strips were separated from the myenteric plexus and circular muscle, rhythmically firing SDs and action potentials were still recorded. Atropine (1 microM) or tetrodotoxin (1 microM) either reduced the frequency of SDs or temporarily abolished activity, whereas nifedipine (1 microM) always abolished SDs and action potentials. Kit-positive interstitial cells of Cajal were present at the level of the myenteric plexus and circular and longitudinal muscle. In summary, SDs and action potentials in LM propagate over discrete localized zones, usually <1 mm around the circumference of the colon. Furthermore, in contrast to the classic slow wave, rhythmic depolarizations in LM appear to be generated by an intrinsic property of the smooth muscle itself and are critically dependent on opening of L-type Ca(2+) channels.  相似文献   

17.
Branched surface EMG electrodes are bipolar electrodes with the hot signal pole referenced to two or more short-circuited leading-off surfaces. This technique provides stable recording of single motor unit potentials during real movements, up to maximal muscle contractions. The selective characteristic of branched electrodes is based on the same principles as the double differential detection system and spatial filtering technique proposed later. Equi-weight calculations to assess the selectivity of different electrode types and their position are used. The main advantage of branched electrodes, especially high stability, is achieved by the wire electrode version. The design, manufacture, implementation, and application of wire electrodes are discussed in detail. During recording of motor unit potentials, electrodes are positioned subcutaneously over the muscle fascia. This positioning maximizes electrode stability. Appropriate orientation of the electrode relative to the muscle architecture ensures adequate selectivity for single motor unit recordings. Branched electrodes require ordinary EMG equipment (two or even one amplifier).  相似文献   

18.
The cardiac refractory period prevents the heart from tetanic activation that is typically used in noncardiac striated muscle tissue. To what extent the refractory period prevents successive action potentials to activate the excitation-contraction coupling process and contractile machinery at supra-physiological rates, such as those present during ventricular fibrillation, is unknown. Using multicellular trabeculae isolated from rat hearts, we studied amplitude and kinetics of contraction at rates well above the normal in vivo rat heart range. We show that even at twice the maximal heart rate of the rat, little or no mechanical instability is observed; twitch contractions are at steady state, albeit with an elevated active diastolic force. Although the amplitude of contraction increased within in vivo heart rates (positive force-frequency response), at frequencies beyond the maximal heart rate (10-30 Hz) a steady decline of contractile amplitude is observed. Not until 30 Hz do the majority of the isolated muscle preparations show mechanical alternans, where strong and weak beats alternate. Interestingly, unlike striated limb skeletal muscle, fusing of twitch contractions did not cause a continuous increase in peak force: at frequencies of 10 Hz and above, systolic force declines with relatively little elevation in diastolic force. Contractile kinetics continued to accelerate, from 1 Hz up to 30 Hz, whereas the relative speed of contraction and relaxation remained closely coupled, reflected by a singular linear relationship between the maximal and minimal derivative of force (dF/dt). We conclude that cardiac muscle can produce mechanically stable steady-state contractions at supra-physiological pacing rates, while these contractions continue to decline in amplitude and increase in diastolic force past maximal heart rate.  相似文献   

19.
Reliability of the motor response (M-wave) is fundamental in many reflex studies; however it has recently been shown to change during some investigations. The aim of this investigation was to determine if triceps surae stretch and voluntary contraction, or recording and analysis techniques, affect the maximal M-wave magnitude. The maximal M-wave was investigated in human gastrocnemius and soleus during different foot positions and during triceps surae contraction. Both bipolar and monopolar-recoding methods, and area and peak-to-peak (PTP) amplitude analysis methods were used. RESULTS: Maximal M-wave magnitude changed significantly between test muscle conditions, and is largest during dorsiflexion, probably due to changes in muscle bulk and recording electrode relationship. The maximal M-wave was up to 88% smaller when recorded by bipolar electrodes compared to monopolar electrodes, which is discussed in relation to signal cancellation. Area analysis provided more significant differences in M-wave magnitude between test muscle conditions than did PTP amplitude analysis, and the maximal M-wave shape changed significantly between test muscle conditions. This study suggests that maximal M-wave magnitude can vary depending on muscle condition, it highlights the importance of using correct recording and analysis techniques, and questions the reliability of using M-wave magnitude to monitor the relationship between the nerves and stimulating electrodes.  相似文献   

20.
Properties of motor unit action potentials (MUAPs) were compared for medial gastrocnemius (MG) motor units (MUs) in cats and rats. The experiments on functionally isolated MUs were performed under general anaesthesia, under comparable conditions (surgery, stimulating protocol and recording methods) for both species investigated. The proportions of motor units and contractile properties of the sample used in the study were consistent with previous studies performed on the MG muscle in both animal species, so comparisons of action potentials of individual types of MUs were acknowledged as fully reliable. The most prominent differences concerning MUAPs were observed in total duration and peak-to-peak times which for all MU types were about twice longer in cat MUs, in comparison to the rat MUs. The considerable disproportions were observed between the MUAP amplitudes of FF (fast fatigable), FR (fast resistant to fatigue) and S (slow) MUs in each species (the highest amplitudes were measured for FF and the lowest for S MUs), but there were no significant differences between cat and rat when respective types of MUs were compared. The shapes of MUAPs were commonly characterized by biphasic waveforms composed of two or three turns in all types of units, and no interspecies differences were revealed. Several factors influencing MUAP parameters were discussed indicating most of all importance of variable length of cat and rat muscle fibres and ambiguous influence of motor unit size, thickness of muscle fibres and their density around the recording electrode in the MG muscle of both species.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号