1.
Powerful directed evolution methods have been developed for tailoring proteins to our needs in industrial applications. Here, the authors report a medium-throughput assay system designed for screening mutant libraries of oxygenases capable of inserting a hydroxyl group into a C-H bond of aromatic or O-heterocyclic compounds and for exploring the substrate profile of oxygenases. The assay system is based on 4-aminoantipyrine (4-AAP), a colorimetric phenol detection reagent. By using 2 detection wavelengths (509 nm and 600 nm), the authors achieved a linear response from 50 to 800 microM phenol and standard deviations below 11% in 96-well plate assays. The monooxygenase P450 BM-3 and its F87A mutant were used as a model system for medium-throughput assay development, identification of novel substrates (e.g., phenoxytoluene, phenylallyether, and coumarone), and discovery of P450 BM-3 F87A mutants with 8-fold improvement in 3-phenoxytoluene hydroxylation activity. This activity increase was achieved by screening a saturation mutagenesis library of amino acid position Y51 using the 4-AAP protocol in the 96-well format.  相似文献   

2.
A retrospective postal survey of 24 000 medical laboratory workers in England, Wales, and Scotland showed highly variable standards of safety and health care. Pre-employment health screening was offered to two-thirds of employees, the physicians being the least likely to be examined (15%). Scottish laboratories provided better safety control than English and Welsh laboratories, while Public Health Service Laboratories had a better record than National Health Service establishments. Mouth pipetting is still practised in 65% of English and Welsh laboratories, and the use of protective clothing is rarely compulsory. The servicing of safety cabinets is often inadequate. Known and suspected carcinogens are still apparently used in a few laboratories (2-10%). In view of the wide variation in standards among laboratories, urgent consideration should be given to establishing regulations for codes of safe practice rather than relying merely on recommendations as at present.  相似文献   

3.
稀有鮈鲫对重铬酸钾和3,4-二氯苯胺急性毒性研究   总被引:1,自引:0,他引:1  
目的和方法稀有鮈鲫(Gobiocypris rarus)作为一种本土特有的小型鱼类,是我国正在标准化的化学品毒性测试生物之一。为评价稀有鮈鲫鱼类急性毒性实验中效应的稳定性和可重复性,研究优化筛选了重铬酸钾和3,4-二氯苯胺两种化学品,分别在单一实验室内及不同实验室间进行急性毒性验证实验。结果对于来源相同、体长固定的稀有鮈鲫,无论在实验室内还是实验室间,两组化学品的96 h LC50值均在x珋±2s的质量控制范围之内,所有结果体现了很好的稳定性和可重复性。结论根据研究获得的数据可建立一个有效的稳定性和可重复性衡量数据库,用来评估之后其他单个实验的可靠性;稀有鮈鲫作为一种具有潜力的生态毒性测试的生物种类,具有成为标准实验动物的潜能。  相似文献   

4.
The Tradescantia stamen hair mutation (Trad-SH) assay (clone 4430) was evaluated for its efficiency and reliability as a screen for mutagens in an IPCS collaborative study on plant systems. Four coded chemicals, i.e. azidoglycerol (AG, 3-azido-1,2-propanediol), N-methyl-N-nitrosourea (MNU), sodium azide (NaN3) and maleic hydrazide (MH) were distributed by the Radian Corporation to the five laboratories in five different countries for testing mutagenicity. Pink mutations were scored between the 7th and 14th day according to a standard protocol. Test results from the five individual laboratories were analyzed and compared after decoding. One out of the two laboratories that conducted tests on AG demonstrated that AG is a mutagen with genetically effective doses ranging from 50 to 100 μg/ml. MH yielded positive responses in all laboratories but no linear dose-response pattern was observed. The effective dose range for MH was between 1 and 45 μg/ml. The mutagenicity of MNU was reported by five laboratories in the dose range between 10 and 80 μg/ml. NaN3, which exhibited a relatively high degree of toxicity, elicited a positive mutagenic response in three of the five laboratories in which it was tested. As with MNU the effective dose for NaN3 ranged between 3 and 80 μg/ml. The results from the current study substantiate the Trad-SH assay as a reliable system for screening chemicals for their potential mutagenic effects. Although the study was carried out exclusively under laboratory conditions, a survey of the current literature would indicate that the Trad-SH assay could be an effective in situ monitor of gaseous, liquid, and radioactive pollutants as well.  相似文献   

5.
A key trend in high-throughput screening is assay miniaturization to control reagent costs and increase throughput. For this purpose, liquid-handling devices are used that transfer nano-to low-microliter volumes into all currently used microtiter well plates. One drawback of many available dispenser and pipetting systems are high dead volumes. Therefore, the authors were looking for an easy and simple solution to modify their standard liquid-handling device, PerkinElmer's FlexDrop Precision IV, allowing for a dead volume reduction to receive maximum benefit from miniaturized assay formats. Internal reservoirs were developed and constructed by Schering's Technical Development Laboratory (TDL), which are directly connected to the dispenser banks of FlexDrop without tubing. Using these newly built reservoirs, the dead volume was decreased by a factor of 5 in comparison to the manufacturer's reservoirs without compromising liquid-handling parameters such as accuracy and precision. The modified system displayed a high robustness and reliability under routine high-throughput screening conditions.  相似文献   

6.
Mycobacterium avium subsp. paratuberculosis (MAP) is a vigorous microorganism which causes incurable chronic enteritis, Johne’s disease (JD) in cattle. A target of control programmes for JD is to accurately detect MAP-infected cattle early to reduce disease transmission. The present study evaluated the efficacy of two different cultural procedures and a TaqMan real-time PCR assay for detection of subclinical paratuberculosis in dairy herds. Therefore, sixty-one faecal samples were collected from two Dutch dairy herds (n = 40 and n = 21, respectively) which were known to be MAP-ELISA positive. All individual samples were assessed using two different cultural protocols in two different laboratories. The first cultural protocol (first laboratory) included a decontamination step with 0.75% hexadecylpyridinium chloride (HPC) followed by inoculation on Herrold’s egg yolk media (HEYM). The second protocol (second laboratory) comprised of a decontamination step using 4% NaOH and malachite green-oxalic acid followed by inoculation on two media, HEYM and in parallel on modified Löwenstein-Jensen media (mLJ). For the TaqMan real-time PCR assay, all faecal samples were tested in two different laboratories using TaqMan® MAP (Johne’s) reagents (Life Technologies). The cultural procedures revealed positive reactions in 1.64% of the samples for cultivation protocol 1 and 6.56 and 8.20% of the samples for cultivation protocol 2, respectively. The results of the TaqMan real-time PCR performed in two different laboratories yielded 13.11 and 19.76% positive reaction. The kappa test showed proportional agreement 0.54 between the mLJ media (second laboratory) and TaqMan® real-time PCR method (second laboratory). In conclusion, the TaqMan real-time PCR could be a strongly useful and efficient assay for the detection of subclinical paratuberculosis in dairy cattle leading to an improvement in the efficiency of MAP control strategies.  相似文献   

7.
In the first phase of a collaborative study by the International Programme on Chemical Safety (PRCS), four coded chemicals, i.e. azidoglycerol (AG, 3-azido-1,2-propanediol), methyl nitrosurea (MNU), sodium azide (NaN3) and maleic hydrazide (MH), and ethyl methanesulfonate (EMS) as a positive control were tested in four plant bioassays, namely the Arabidopsis embryo and chlorophyll mutation assay, the Tradescantia stamen hair assay (Trad-SH assay), the Tradescantia micronucleus assay (Trade-MCN), and the Vicia faba root tip assay. Seventeen laboratories from diverse regions of the world participated with four to six laboratories each using one plant assay. For the Arabidopsis assay, laboratories were in agreement with MNU and AG giving positive responses and NaN3 giving a negative response. With the exception of one laboratory which reported MH as weakly mutagenic, no mutagenic response was reported for MH by the other laboratories. For the Vicia faba assay, all laboratories reported a positive response for MNU, AG, and MH, whereas two of the six laboratories reported a negative response for NaN3. For the Trad-SH assay, MH was reported as giving a positive response and a positive response was also observed for MNU with the exception of one laboratory. NaN3, which exhibited a relatively high degree of toxicity, elicited a positive response in three of the five laboratories. AG was found positive in only one of the two laboratories which tested this chemical. For the Trad-MCN assay, MNU and MH were reported as positive by all laboratories, while four out of five laboratories reported NaN3 to be positive. Only one of three laboratories reported AG to be positive. The major sources of variability were identified and considered to be in the same range as found in similar studies on other test systems. Recommendations were made for minor changes in methodology and for initiating the second phase of this study.  相似文献   

8.
During the past several years, the use of animals for toxicity testing has come under critical surveillance. For ethical and economic reasons, various techniques have been developed and proposed as potential alternatives for some of the whole animal toxicity assays. One assay proposed as an alternative to animal testing is the luminescent bacteria toxicity test (LBT), provided under the trade name of Microtox®. The sensitivity and specificity of the LBT was compared with two commonly used toxicity tests–-the L-929 Minimal Eùgle's Medium (MEM) elution cytotoxicity test and the Draize test. Cytotoxicity and LBT test data from 709 medical device and biomaterial extracts were compared using a positive/negative ranking system which provided a measurement of false positive and false negative results. These data were compiled from nine separate laboratories producing or using a wide variety of biomaterials and medical device products. The LBT was more sensitive than the tissue culture assay and displayed few false negatives. LBT EC50 values were compared with eye irritancy categories for a group of 34 chemicals and 27 personal care products. As with tissue culture, the LBT was more sensitive and produced minimal false negatives. The data from this study indicate the LBT has potential as a rapid, simple method to screen biomaterials and personal care products for toxicity and irritancy.  相似文献   

9.

Background

Schistosomiasis, one of the world’s greatest neglected tropical diseases, is responsible for over 280,000 human deaths per annum. Praziquantel, developed in the 1970s, has high efficacy, excellent tolerability, few and transient side effects, simple administration procedures and competitive cost and it is currently the only recommended drug for treatment of human schistosomiasis. The use of a single drug to treat a population of over 200 million infected people appears particularly alarming when considering the threat of drug resistance. Quantitative, objective and validated methods for the screening of compound collections are needed for the discovery of novel anti-schistosomal drugs.

Methodology/Principal Findings

The present work describes the development and validation of a luminescence-based, medium-throughput assay for the detection of schistosomula viability through quantitation of ATP, a good indicator of metabolically active cells in culture. This validated method is demonstrated to be fast, highly reliable, sensitive and automation-friendly. The optimized assay was used for the screening of a small compound library on S. mansoni schistosomula, showing that the proposed method is suitable for a medium-throughput semi-automated screening. Interestingly, the pilot screening identified hits previously reported to have some anti-parasitic activity, further supporting the validity of this assay for anthelminthic drug discovery.

Conclusions

The developed and validated schistosomula viability luminescence-based assay was shown to be successful and suitable for the identification of novel compounds potentially exploitable in future schistosomiasis therapies.  相似文献   

10.
The reproducibility of the binary typing (BT) protocol developed for epidemiological typing of Staphylococcus aureus was analyzed in a biphasic multicenter study. In a Dutch multicenter pilot study, 10 genetically unique isolates of methicillin-resistant S. aureus (MRSA) were characterized by the BT assay as presented by van Leeuwen et al. [J. Clin. Microbiol. 2001 39 (1) 328]. The BT assay, including a standardized DNA extraction protocol was performed in duplicate in eleven medical microbiology laboratories. Two different hybridization detection procedures were applied and a prelabeled DNA sample as process control was included. Only three laboratories accurately identified all strains. Divergence in technical procedures resulted in misinterpretation due to an increasing number of faint or absent hybridization signals in combination with high background staining. The binary type of the process control was determined correctly by all participating laboratories. The feasibility of the BT protocol was related directly to the skill of the laboratory personnel. On the basis of the national study, we concluded that the DNA extraction protocol needed modification to improve DNA yield and purity. Subsequently, seven European laboratories participated in an international study to determine the reproducibility of the modified BT protocol. Each center was asked to analyze 10 DNA samples previously extracted from 10 MRSA strains (phase 1) and, additionally, to analyze 10 MRSA strains, using the standardized or their in-house DNA isolation protocol (phase 2). A prelabeled DNA process control sample was included again. The binary types of all DNA samples were identified correctly by all but one laboratories. This latter laboratory diverged from the protocol by adding an excess of labeled DNA to the hybridization mixture, resulting in a high background and, therefore, noninterpretable BT results. All centers produced identical BT results for the process control. Five of the seven centers correctly identified the binary types of all 10 MRSA strains in phase 2 of the international study. Three of these centers used their in-house DNA extraction protocol. Divergence from the standard BT protocol in the remaining two centers resulted in no interpretable BT data for the 10 MRSA strains. The study demonstrated that each center that followed the BT protocol to the letter could generate reproducible results, irrespective whether or not an in-house DNA isolation protocol was used. The current BT protocol thus represents a simple method generating robust, reproducible genotype data for S. aureus strains.  相似文献   

11.
Sixteen coded compounds were blind-tested at 4 laboratories using the recently described GADD45a-GFP genotoxicity assay. The compounds were chosen to include non-genotoxic compounds as well as weak and strong genotoxins. None of the compounds required metabolic activation in order to exhibit genotoxic effects. The participating laboratories included 2 global pharmaceutical companies, a global consumer goods company and the Gentronix laboratory in Manchester. Each compound was tested 4 times on different days following a protocol previously described. The tests were carried out after a 3-day training period from the parent lab (Manchester). Following the exclusion of data from tests with positive control failures and data series with 'spikes', 92% of assays gave the correct result: non-genotoxins giving negative results and genotoxins giving positive results. There were no randomly distributed problems suggesting that differences between the results from different sites reflected the use of different instruments, procedural differences and operator experience. In na?ve operator laboratories the quality of data improved with operator practice. It was concluded that simple clarification of the protocol would provide the level of reliability required for widespread use of the assay in hazard assessment.  相似文献   

12.
Accurate determination of lipid concentrations is an obligatory routine in a research laboratory engaged in studies using this class of biomaterials. For phospholipids, this is frequently accomplished using the phosphate assay (Bartlett, G.R. Phosphorus Assay in Column Chromatography. J. Biol. Chem. 234, 466-468, 1959). Given the purity of the currently commercially available synthetic and isolated natural lipids, we have observed that determination of the dry weight of lipid stock solutions provides the fastest, most accurate, and generic method to assay their concentrations. The protocol described here takes advantage of the high resolution and accuracy obtained by modern weighing technology. We assayed by this technique the concentrations of a number of phosphatidylcholine samples, with different degrees of acyl chain saturation and length, and in different organic solvents. The results were compared with those from Bartlett assay, (31)P NMR, and Langmuir compression isotherms. The data obtained show that the gravimetric assay yields lipid concentrations with a resolution similar or better than obtained by the other techniques.  相似文献   

13.
The European Centre for the Validation of Alternative Methods (ECVAM) has organised an interlaboratory prevalidation study on the Syrian hamster embryo (SHE) cell transformation assay (CTA) at pH 7.0 for the detection of rodent carcinogens. The SHE CTA at pH 7.0 has been evaluated for its within-laboratory reproducibility, transferability and between-laboratory reproducibility. Four laboratories using the same basic protocol with minor modifications participated in this study and tested a series of six coded-chemicals: four rodent carcinogens (benzo(a)pyrene, 3-methylcholanthrene, 2,4-diaminotoluene and o-toluidine HCl) and two non-carcinogens (anthracene and phthalic anhydride). All the laboratories found the expected results with coded chemicals except for phthalic anhydride which resulted in a different call in only one laboratory. Based on the outcome of this study, it can be concluded that a standardised protocol is available that should be the basis for future use. This protocol and the assay system itself are transferable between laboratories and the SHE CTA at pH 7.0 is reproducible within- and between-laboratories.  相似文献   

14.
The Bhas 42 cell transformation assay is a sensitive short-term system for predicting chemical carcinogenicity. Bhas 42 cells were established from BALB/c 3T3 cells by the transfection of v-Ha-ras gene and postulated to have acquired an initiated state in the two-stage carcinogenesis theory. The Bhas 42 cell transformation assay is capable of detecting both tumor-initiating and tumor-promoting activities of chemical carcinogens. The full assay protocol consists of two components, the initiation assay and the promotion assay, to detect the initiating activity and the promoting activity, respectively. An international study was carried out to validate this cell transformation assay in which six laboratories from three countries participated. Twelve coded chemicals were examined in total and each chemical was tested by three laboratories. In the initiation assay, concordant results were obtained by three laboratories for eight out of ten chemicals and in the promotion assay, concordant results were achieved for ten of twelve chemicals. The positive results were obtained in all three laboratories with the following chemicals: 2-acetylaminofluorene was positive in both initiation and promotion assays; dibenz[a,h]anthracene was positive in the initiation assay; sodium arsenite, lithocholic acid, cadmium chloride, mezerein and methapyrilene hydrochloride were positive in the promotion assay. o-Toluidin hydrochloride was positive in the both assays in two of the three laboratories. d-Mannitol, caffeine and l-ascorbic acid were negative in both assays in all the laboratories, and anthracene was negative in both assays in two of the three laboratories except one laboratory obtaining positive result in the promotion assay. Consequently, the Bhas 42 cell transformation assay correctly discriminated all six carcinogens and two tumor promoters from four non-carcinogens. Thus, the present study demonstrated that the Bhas 42 cell transformation assay is transferable and reproducible between laboratories and applicable to the prediction of chemical carcinogenicity. In addition, by comparison of the present results with intra-laboratory data previously published, within-laboratory reproducibility using the Bhas 42 cell transformation assay was also confirmed.  相似文献   

15.
The multicellular model organism Caenorhabditis elegans is a small nematode of approximately 1 mm in size in adulthood that is genetically and experimentally tractable. It is economical and easy to culture and dispense in liquid medium which makes it well suited for medium-throughput screening. We have previously validated the use of transgenic luciferase expressing C. elegans strains to provide rapid in vivo assessment of the nematode’s ATP levels.1-3 Here we present the required materials and procedure to carry out bioassays with the bioluminescent C. elegans strains PE254 or PE255 (or any of their derivative strains). The protocol allows for in vivo detection of sublethal effects of drugs that may identify mitochondrial toxicity, as well as for in vivo detection of potential beneficial drug effects. Representative results are provided for the chemicals paraquat, rotenone, oxaloacetate and for four firefly luciferase inhibitory compounds. The methodology can be scaled up to provide a platform for screening drug libraries for compounds capable of modulating mitochondrial function. Pre-clinical evaluation of drug toxicity is often carried out on immortalized cancerous human cell lines which derive ATP mostly from glycolysis and are often tolerant of mitochondrial toxicants.4,5 In contrast, C. elegans depends on oxidative phosphorylation to sustain development into adulthood, drawing a parallel with humans and providing a unique opportunity for compound evaluation in the physiological context of a whole live multicellular organism.  相似文献   

16.
Analyzing the effects on cell growth inhibition and/or cell death has been an important component of biological research. The MTS assay and LDH-based cytotoxicity assays are two of the most commonly used methods for this purpose. However, data here showed that MTS cell proliferation assay could not distinguish the effects of cell death or cell growth inhibition. In addition, the original LDH-based cytotoxicity protocol grossly underestimated the proportion of dead cells in conditions with growth inhibition. To overcome the limitation, we present here a simple modified LDH-based cytotoxicity protocol by adding additional condition-specific controls. This modified protocol thus can provide more accurate measurement of killing effects in addition to the measurement of overall effects, especially in conditions with growth inhibition. In summary, we present here a simple, modified cytotoxicity assay, which can determine the overall effects, percentage of cell killing and growth inhibition in one 96-well based assay. This is a viable option for primary screening for many laboratories, and could be adapted for high throughput screening.  相似文献   

17.
Summary A report by Bullock and coworkers has emphasized the need for standardization of the CK assay in carrier detection for DMD. A collaborative study, according to a well-specified design and involving two laboratories in Paris and Lyon, indicates that the reliability of this assay can be improved provided that special attention is paid to information about participating subjects, laboratory protocol, and repeated sampling. On a random sample of young women, mean and variance of 1n(CK) are 1.66 and 0.015 respectively. Within and between variance components are in a 3:4 ratio, homogeneous between populations. Additional use of a common test serum should insure good reliability of this assay among laboratories.  相似文献   

18.
19.
Methods for rapid and direct quantification of enzyme kinetics independent of the substrate stand in high demand for both fundamental research and bioprocess development. This study addresses the need for a generic method by developing an automated, standardizable HPLC platform monitoring reaction progress in near real‐time. The method was applied to amine transaminase (ATA) catalyzed reactions intensifying process development for chiral amine synthesis. Autosampler‐assisted pipetting facilitates integrated mixing and sampling under controlled temperature. Crude enzyme formulations in high and low substrate concentrations can be employed. Sequential, small (1 µL) sample injections and immediate detection after separation permits fast reaction monitoring with excellent sensitivity, accuracy and reproducibility. Due to its modular design, different chromatographic techniques, e.g. reverse phase and size exclusion chromatography (SEC) can be employed. A novel assay for pyridoxal 5'‐phosphate‐dependent enzymes is presented using SEC for direct monitoring of enzyme‐bound and free reaction intermediates. Time‐resolved changes of the different cofactor states, e.g. pyridoxal 5'‐phosphate, pyridoxamine 5'‐phosphate and the internal aldimine were traced in both half reactions. The combination of the automated HPLC platform with SEC offers a method for substrate‐independent screening, which renders a missing piece in the assay and screening toolbox for ATAs and other PLP‐dependent enzymes.  相似文献   

20.
The identification of mycobacterial species in clinical isolates is essential for making patient care decisions. Polymerase chain reaction (PCR) restriction enzyme analysis (PRA) is a simple and rapid identification method, based on amplification of 441 bp of the hsp65 gene and restriction with BstEII and HaeIII. As a contribution to the validation of PRA, a multicenter study was performed in eight laboratories located in Argentina, Brazil, Colombia, Chile, and Guadeloupe. Each laboratory received 18 coded isolates from the collection of the Institute of Tropical Medicine (Antwerp, Belgium), representing duplicates of nine laboratory strains: Mycobacterium terrae CIPT 140320001, Mycobacterium scrofulaceum CIPT 140220031, Mycobacterium flavescens ATCC 14474, Mycobacterium triviale ATCC 23292, Mycobacterium nonchromogenicum ATCC 19530, Mycobacterium chitae ATCC 19627, Mycobacterium abscessus ATCC 19977, Mycobacterium kansasii ATCC 12478, and Mycobacterium peregrinum ATCC 14467. A detailed protocol including amplification, enzymatic digestion, and gel preparation was provided to each laboratory. Two laboratories identified correctly all 18 (100%) isolates, one identified correctly 17 (94.5%), two identified 14 (77.7%), one identified 11 (61%), and two identified 8 (44.4%) isolates. Errors detected in laboratories with more than 77% accuracy were associated with electrophoresis running conditions and an unspecific amplicon produced by a single strain. Lower accuracy was mainly related to inappropriate use of DNA markers and insufficient training in interpretation of patterns. In conclusion, the PRA method was readily implemented in some Latin American and Caribbean laboratories of mycobacteria, but improvements in critical points, as gel running conditions and training in interpretiation of patterns, are needed in order to improve accuracy. In others, improvement in critical points is still necessary.  相似文献   